"1 electrical building wires pvc or lszh low smoke zero halogen"
- 70 Items Found
ZR-YJV 4×35mm² Flame Retardant Copper Power Cable, 0.6/1kV XLPE Insulated PVC Sheath
ZR-YJV 4×35mm² Flame Retardant Copper Power Cable, 0.6/1kV XLPE Insulated PVC Sheath Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×35 mm² Four equal cores of 35 mm² copper conductor Construction ...
ZC-YJV 4x50mm² Class C Flame Retardant XLPE Copper Power Cable for Building Distribution
ZC-YJV 4x50mm² Class C Flame Retardant XLPE Copper Power Cable for Building Distribution Cable Designation & Meaning Code Meaning ZC Flame retardant Category C (GB/T 18380.3) YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath 4×50 mm² Four cores, each 50 mm² copper (3 phases + 1 ...
RVV 2x0.75mm2 2 Core Flexible Cable Stranded Copper Conductor PVC Sheathed
RVV-2*0.75mm² Flexible Control Cable 2 Core Stranded Copper Conductor PVC Insulated PVC Outer Sheathed Cable Designation & Meaning Code Meaning R Flexible conductor V PVC insulation V PVC sheath 2×0.75 mm² Two cores of 0.75 mm² copper conductor Construction : Two 0.75 mm² fine-stranded copper ...
ZR-YJV 4×50mm² 0.6/1kV Flame Retardant Copper Cable, XLPE Insulation for Building Power Distribution
ZR-YJV 4×50mm² 0.6/1kV Flame Retardant Copper Cable, XLPE Insulation for Building Power Distribution Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×50 mm² Four equal cores of 50 mm² copper ...
ZR-YJV 4*120mm² Flame Retardant Copper Power Cable for Building & Industrial Wiring
ZR-YJV 4*120mm² Flame Retardant Copper Power Cable for Building & Industrial Wiring Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×120 mm² Four equal cores of 120 mm² copper conductor Construction ...
High Capacity 5 Core Flex ZR-YJV 4x300mm2+1x150mm2 XLPE Copper Flame Retardant
High Capacity 4+1 Core Cable ZR-YJV 4x300mm²+1x150mm² XLPE Copper Flame Retardant Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — ...
ZR-YJV 4×70mm² 0.6/1kV Flame Retardant Copper Cable, XLPE Insulation for Building Power Distribution
ZR-YJV 4×70mm² 0.6/1kV Flame Retardant Copper Cable, XLPE Insulation for Building Power Distribution Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×70 mm² Four equal cores of 70 mm² copper ...
Copper Conductor Flame Retardant XLPE Cable ZR-YJV 3×95mm²+1×50mm² for Site Power Wiring
Copper Conductor Flame Retardant XLPE Cable ZR-YJV 3×95mm²+1×50mm² for Site Power Wiring Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 3×95 mm² + 1×50 mm² Three phase cores of 95 mm² + one neutral ...
BTLY Fire Rated Cable 4x35mm2 + 1x16mm2 Aluminum Sheath Cable For Emergency
NG-A BTLY 4x35+1x16mm2 Mineral Insulated Fire Resistant Aluminum Sheath Cable for Emergency Cable Designation & Meaning Code Meaning NG-A New Generation A-class fire-resistant (Chinese designation) (BTLY) Building wire, Thin copper conductor, Lightweight Y— alternative naming convention indicating: ...