ZR-YJV 4×35mm² Flame Retardant Copper Power Cable, 0.6/1kV XLPE Insulated PVC Sheath

ZR-YJV 4×35mm² Flame Retardant Copper Power Cable, 0.6/1kV XLPE Insulated PVC Sheath

Basic Properties

country of origin
China
brand name
TD
certificate
CE/ISO/CCC
product model
ZR-YJV 4×35mm²

Trading Properties

moq
100 meters
payment method
L/C,T/T
supply capacity
10000 meters per month

Product Summary

ZR-YJV 4×35mm² Flame Retardant Copper Power Cable, 0.6/1kV XLPE Insulated PVC Sheath Code Mean:ZR-Flame Retardant,YJ-XLPE Insulated,V-PVC Sheath ZR-YJV 4×35 mm² — Cable Data Report 1. Product at a Glance. ZR-YJV 4×35 is a four-core flame-retardant LV cable — four 35 mm² copper conductors, XLPE ...

Product Details

Highlight:

zr-yjv 4 cores cable

,

zr-yjv 25 sq mm 4 core cable

,

copper 4 cores cable

Currentrating:
25A
Insulationmaterial:
PVC
Numberofcores:
4
Shielding:
None
Cablediameter:
10mm
Flameretardant:
Yes
Cabletype:
Multi-core Power Cable
Colorcode:
Red, Yellow, Blue, Black
Standardcompliance:
IEC 60502
Conductormaterial:
Copper
Outersheathmaterial:
PVC
Temperaturerating:
-20°C To 70°C
Productname:
4 Cores Cable
Voltagerating:
600/1000V
Application:
Power Distribution, Industrial Wiring

Product Description

ZR-YJV 4×35mm² Flame Retardant Copper Power Cable, 0.6/1kV XLPE Insulated PVC Sheath


Code Mean:ZR-Flame Retardant,YJ-XLPE Insulated,V-PVC Sheath

ZR-YJV 4×35 mm² — Cable Data Report 

1. Product at a Glance. ZR-YJV 4×35 is a four-core flame-retardant LV cable — four 35 mm² copper conductors, XLPE insulation, PVC sheath, rated 0.6/1 kV (Um = 1.2 kV), 50 Hz. Built to GB/T 12706.1 / IEC 60502-1, conductors per GB/T 3956 / IEC 60228, fire class ZC (ZR) per GB/T 19666 / GB/T 18380.


ZR-YJV 4×35mm² Flame Retardant Copper Power Cable, 0.6/1kV XLPE Insulated PVC Sheath


2. Construction Stack. Conductor → outer sheath:

Layer Build Wall Diameter
Conductor (×4) Annealed Cu, Class 2, 7 × 2.52 mm (7/2.52) each, 35 mm² per core — ≈ 7.56 mm per core
Insulation (×4) Cross-linked polyethylene 0.9 mm ≈ 9.36 mm per core (over ins.)
Lay-up Four cores + central filler + binder tape — ≈ 22.6 mm (calc.)
Sheath Flame-retarded PVC, ST2, black 1.8 mm ≈ 27.1 mm overall

Approx. weight ≈ 1626 kg/km (Al version ≈ 731.8 kg/km).


3. Electrical Ratings. DC resistance ≤ 0.524 Ω/km per core @ 20 °C; routine 3.5 kV / 5 min; XLPE volume resistivity ≥ 1×10¹² Ω·cm; typical finished insulation resistance ≥ 36.7 MΩ·km; capacitance ≤ 0.45 μF/km per core. Reference ampacity (all four cores loaded) ≈ 125 A in air / 155 A direct-buried @ 25 °C — Mingda 4×35 and Lvbao 4×35+1×16 agree exactly (125/155 A).


Parameter

Value

Note

Rated voltage U₀/U

0.6 / 1 kV

Uₘ = 1.2 kV

Test voltage AC (5 min)

3.5 kV

Routine

Type-test voltage

4.0 kV

IEC 60502

DC resistance @20 °C (Class 2 Cu, per core)

≤ 0.524 Ω/km

GB/T 3956 max

AC resistance @90 °C (est.)

≈ 0.681 Ω/km

per core

Current rating in air (30 °C, single circuit, 4-core)

≈ 95 – 108 A

design ≈ 102 A

Direct buried (20 °C, soil 1.0 K·m/W, 0.7 m)

≈ 118 – 132 A

design ≈ 125 A

Short-circuit current (1 s, Cu, 250 °C, per core)

≈ 3.50 kA

reference

Frequency

50/60 Hz AC

—


4. Thermal & Mechanical. Continuous 90 °C; short-circuit 250 °C (≤ 5 s); ambient −20 to +45 °C; laying ≥ 0 °C; min. bend radius ≥ 15 × OD (multi-core).


ZR-YJV 4×35 mm² Flame-Retardant Copper-Conductor XLPE-Insulated PVC-Sheathed Power Cable — Product Parameters (0.6/1 kV, Four-Core)
Construction: CU / XLPE / PVC, 4 cores  •  Standards: GB/T 12706.1, IEC 60502-1 (cable), GB/T 3956 (conductor), GB/T 19666 & GB/T 18380 (flame retardance)  •  Nominal values for reference — confirm against factory test certificate
No. Category Parameter Value Unit Notes / Standard Reference
A. Product Identification
1 Identification Product name Flame-retardant copper-conductor XLPE-insulated PVC-sheathed power cable (four-core) — Designation ZR-YJV; "ZR" = flame-retardant, halogen-containing
2 Identification Model designation ZR-YJV 4×35 — 4 cores × 35 mm²; Cu / XLPE / PVC
3 Identification Design standards GB/T 12706.1; IEC 60502-1 — Conductor: GB/T 3956 / IEC 60228; fire rating: GB/T 19666, GB/T 18380
4 Identification Rated voltage U0/U 0.6/1 kV Max system voltage Um = 1.2 kV
5 Identification Rated frequency 50 Hz AC power distribution
6 Identification Number of cores 4 — Three phases (L1/L2/L3) + neutral (N)
7 Identification Nominal cross-sectional area 35 mm² Per core; nominal section per GB/T 3956
B. Cable Construction (from conductor to outer sheath)
8 Conductor Material Plain annealed copper (Cu) — High-conductivity copper
9 Conductor Conductor class Class 1 or Class 2 (typical: Class 2, stranded) — GB/T 3956 / IEC 60228
10 Conductor Typical stranding construction (per core) 7 wires × 2.52 mm (7/2.52) — Class 2 round stranded; nominal section 35 mm² per core
11 Conductor Conductor diameter (per core) ≈ 7.56 mm Ø of the 7/2.52 stranded core (3 × 2.52)
12 Conductor Max. DC resistance of conductor at 20 °C 0.524 Ω/km GB/T 3956, Class 2 copper
13 Insulation Material Cross-linked polyethylene (XLPE) — Thermally cross-linked; natural/transparent
14 Insulation Nominal insulation thickness 0.9 mm GB/T 12706.1 / IEC 60502-1 (0.6/1 kV, 25–35 mm² band)
15 Insulation Diameter over insulation (per core) ≈ 9.36 mm ≈ 7.56 + 2 × 0.9 (calculated)
16 Lay-up Core assembly Four insulated cores laid up around a central non-hygroscopic filler; binder tape over the bundle — Round construction; classic 4-core geometry
17 Sheath Material Flame-retardant polyvinyl chloride (PVC, ST2 type) — Colour: black (or as ordered)
18 Sheath Nominal sheath thickness 1.8 mm GB/T 12706.1 / IEC 60502-1 (Mingda four-core table)
19 Dimensions Approx. overall diameter ≈ 27.1 mm Mingda 27.1 (four-core unarmored)
20 Dimensions Approx. cable weight ≈ 1626 kg/km Mingda 1626 (aluminium version ≈ 731.8 kg/km)
C. Electrical Performance
21 Electrical Max. DC conductor resistance at 20 °C 0.524 Ω/km GB/T 3956; routine measurement (per core)
22 Electrical Power-frequency withstand voltage (routine test) 3.5 kV / 5 min, no breakdown — AC 50 Hz; per GB/T 12706.1 / IEC 60502-1
23 Electrical Insulation resistance (finished cable, 20 °C) ≥ 36.7 MΩ·km Typical finished-cable reference for 0.6/1 kV XLPE cables
24 Electrical XLPE volume resistivity at 20 °C ≥ 1 × 10¹² Ω·cm Material-level requirement (manufacturer reference)
25 Electrical Capacitance (approx., per core) ≤ 0.45 μF/km Manufacturer reference value
26 Electrical Reference ampacity — in air, 25 °C, four cores loaded ≈ 125 A Mingda 125 A; Lvbao 4×35+1×16 also 125 A @25 °C
27 Electrical Reference ampacity — direct burial, 25 °C ≈ 155 A Mingda 155 A; Lvbao 4×35+1×16 155 A; soil thermal resistivity dependent
D. Thermal Performance
28 Thermal Max. continuous conductor temperature 90 °C XLPE insulation temperature class
29 Thermal Max. conductor temperature under short-circuit (≤ 5 s) 250 °C Per GB/T 12706.1 / IEC 60502-1
30 Thermal Ambient service temperature range -20 to +45 °C Per manufacturer datasheet family; check project specification
31 Thermal Min. installation (laying) temperature 0 °C Pre-heat the cable if ambient is below 0 °C
E. Flame Retardance (ZR)
32 Flame retardance Flame-retardant class ZC (class C) by default for "ZR" — GB/T 19666; ZA / ZB available on request; halogen-containing PVC (not LSZH)
33 Flame retardance Single-cable vertical flame-spread test Pass — GB/T 18380.12
34 Flame retardance Bunched flame-spread test (class C) Char extent ≤ 2.5 m above burner bottom edge — GB/T 18380.35: non-metallic volume ≥ 1.5 L/m; flame application 20 min
35 Flame retardance Halogen content Halogen-containing (PVC) — For low-smoke, zero-halogen requirement select WDZ-YJY (LSZH) type
F. Installation
36 Installation Min. bending radius — multi-core cable ≥ 15 × OD — GB 50168 practice for multi-core XLPE cables
37 Installation Laying methods Conduit, tray, cable trench, duct, building trunking, supported/suspended aerial — Direct burial with mechanical protection where permitted
38 Installation Site withstand test after installation DC 4U0 = 2.4 kV, 15 min (recommended) — Per utility procurement standard Q/GDW 13244.1-2018
G. Packing & Delivery
39 Packing Standard delivery length 100 m per coil/drum (or as ordered) — Typical industry practice; custom lengths available
40 Packing Cable marking Model, rated voltage, manufacturer, year of manufacture, sequential length marks — Per GB/T 6995 / project specification
41 Packing Packing form Coil (carton drum) / wooden drum / export packing — As per customer requirement


5.Test Parameters


ZR-YJV 4×35 mm² — Test / Verification Parameters (per GB/T 12706.1 & IEC 60502-1)
Test Stage Test Item Method / Standard Requirement / Acceptance Criterion Notes
Routine test Conductor DC resistance measurement GB/T 3956 (IEC 60228) ≤ 0.524 Ω/km at 20 °C (per core) Measured on every production length
Routine test Power-frequency withstand voltage GB/T 12706.1 / IEC 60502-1 3.5 kV AC, 5 min, no breakdown Applied between each conductor and earth/water; 50 Hz
Routine test Construction check — insulation & sheath thickness, outer diameter GB/T 2951 Within GB/T 12706.1 tolerances Insulation ≥ 0.9 mm nominal; sheath ≥ 1.8 mm nominal
Sample test Hot set (thermal elongation) test — XLPE insulation GB/T 12706.1 §16.3.13 / GB/T 2951.11 200 ± 3 °C, 15 min, stress 0.2 MPa: elongation under load ≤ 175 %; permanent elongation after cooling ≤ 15 % Verifies degree of cross-linking
Sample test Conductor construction & diameter check GB/T 3956 Class 2; 7 × 2.52 mm; Ø ≈ 7.56 mm Sampled per batch
Type test Single-cable vertical flame-spread test (flame retardance) GB/T 18380.12 No flame spread; charring does not reach top reference point ZR / ZC flame-retardant property
Type test Bunched flame-spread test, class C GB/T 18380.35 Char extent ≤ 2.5 m above burner bottom edge; flame application 20 min; non-metallic volume ≥ 1.5 L/m Class ZC per GB/T 19666
Type test Bending test (mechanical) GB/T 12706.1 Bend around specified mandrel without insulation/sheath damage Mandrel diameter related to cable OD (multi-core)
Post-installation DC withstand test after installation Q/GDW 13244.1-2018 (recommended practice) 4U0 = 2.4 kV DC, 15 min, no breakdown For new installations; verify project specification
Optional Insulation resistance measurement at 20 °C Manufacturer test method ≥ 36.7 MΩ·km (typical finished-cable value) Not a routine item in GB/T 12706.1; confirm with factory
Optional XLPE volume resistivity at 20 °C Manufacturer / material test ≥ 1 × 10¹² Ω·cm Material-level reference


6. Fire Behaviour. Passes GB/T 18380.12 single-burn and class-C bunched GB/T 18380.35 (char ≤ 2.5 m) → ZC per GB/T 19666. PVC is halogen-containing — choose WDZ-YJY where LSZH is mandated.


Technical Datasheet — Flame-Retardant (FR) Characteristics
ZR-YJV  0.6/1 kV  4 × 35 mm²  (Cu / XLPE / FR-PVC)
1.  Cable Identification
Code / Item Meaning / Value Standard / Note
ZR Flame Retardant (legacy prefix); under GB/T 19666-2019 defaults to Class C; modern equivalent = ZC GB/T 19666-2019
YJ XLPE — cross-linked polyethylene insulation —
V PVC outer sheath — flame-retardant grade, contains halogen (Cl) GB/T 19666-2019
0.6/1 kV Rated voltage U₀/U = 600/1000 V; maximum Uₘ = 1.2 kV IEC 60502-1
4 × 35 mm² Four cores, nominal copper conductor area 35 mm² per core (all cores equal) —
Construction Unarmoured, non-screened, round multi-core —
Application note Four-core → three-phase AC with neutral (L1+L2+L3+N) or with PE (L1+L2+L3+PE), equal conductor sizes —
2.  Flame-Retardant & Fire Performance  (CORE)
Property Value / Requirement Standard
Flame Retardant Class Class C (bundled cables, char length ≤ 2.5 m) GB/T 19666-2019; GB/T 18380.3 / IEC 60332-3-24
Legacy designation ZR (= ZC); modern prefix preferred: ZC GB/T 19666-2019
Test method — flame Bunched flame test (category C), char ≤ 2.5 m after flame removal GB/T 18380.3 (IEC 60332-3-24)
Halogen content Contains halogen — Cl from PVC sheath; releases HCl on burning GB/T 17650 / IEC 60754-1/-2
Smoke density Heavy dark smoke — NOT low-smoke (no LSZH certification) GB/T 17651 / IEC 61034
Corrosivity Corrosive — HCl gas generated during fire GB/T 17650 / IEC 60754-2
pH / conductivity of gases Not certified (PVC base — acidic / conductive combustion gases) GB/T 17650 / IEC 60754-2
Limited Oxygen Index (LOI) PVC typical ≈ 45–49 % O₂ (reference, design value) ASTM D2863 / GB/T 2406, reference
Max. conductor operating temp. 90 °C (long-term service) GB/T 12706.1-2020
Max. short-circuit temp. (≤5 s) 250 °C IEC 60502-1
Emergency overload temp. 105 °C (up to 130 °C transient) IEC 60502-1
Service ambient range (PVC sheath) −15 °C to +90 °C —
Min. installation ambient temp. 0 °C (pre-heat required below 0 °C) —
3.  Fire Test Summary
Test Requirement ZR-YJV 4×35 Verdict
Bunched flame test (Class C) Char length ≤ 2.5 m PASS (design, Class C)
Single flame test (IEC 60332-1) Self-extinguishing PASS (XLPE/PVC FR)
Smoke density (IEC 61034) Light transmittance ≥ 60 % for LSZH N/A (PVC = heavy smoke)
Halogen content (IEC 60754) ≤ 0.5 % HCl for LSZH N/A (contains Cl)
Acidity / corrosivity (IEC 60754-2) pH ≥ 4.3; conductivity ≤ 10 µS/mm for LSZH N/A (corrosive HCl)
Fire-survival (BS 6387 / IEC 60331) Circuit integrity during/after fire N/A — use NH-ZR-YJV
4.  Key Electrical & Thermal Parameters
Parameter Value Note
Rated voltage U₀/U 0.6 / 1 kV Uₘ = 1.2 kV
Test voltage AC (5 min, routine) 3.5 kV IEC 60502-1
Type-test voltage 4.0 kV IEC 60502-1
DC resistance @ 20 °C (per core) ≤ 0.524 Ω/km GB/T 3956 / IEC 60228, Class 2 max
AC resistance @ 90 °C (est.) ≈ 0.681 Ω/km per core
Current rating — in air (30 °C, single circuit) ≈ 95–108 A (design ≈ 102 A) 4-core
Current rating — direct buried (20 °C, soil 1.0 K·m/W, 0.7 m) ≈ 118–132 A (design ≈ 125 A) 4-core
Short-circuit current (1 s, Cu, 250 °C, per core) ≈ 3.50 kA reference
5.  Construction & Material Specification
Layer (inside → out) Description / Specification FR Contribution
Conductor (×4) Bare annealed copper, Class 2 stranded, 7×∅2.52 mm, conductor Ø ≈ 7.5 mm None (Cu non-combustible)
Conductor screen Omitted (not required for 0.6/1 kV) —
Insulation (×4) XLPE, colours: brown/black/grey/blue etc., 0.9 mm nominal XLPE — low flame spread
Filler Flame-retardant PP / PE to form round assembly FR additive
Binder Flame-retardant tape over laid-up cores FR barrier
Outer sheath Flame-retardant PVC (ZR grade), 1.8 mm nominal, black Primary FR layer (halogenated)
Armour None —
Metallic screen None —
6.  Dimensional Data
Item Typical Value Remarks
Conductor nominal area (per core) 35 mm² —
Number of cores 4 —
Conductor construction Class 2, 7×∅2.52 mm min. 7 wires
Conductor diameter (approx.) 7.5 mm —
Insulation thickness 0.9 mm 35 mm² class
Diameter over insulated core 9.3 mm 7.5 + 2×0.9
Sheath thickness 1.8 mm multi-core rule, ≥ 1.8 mm
Overall cable diameter 23.0 – 24.5 mm (use 23.8 mm for design) —
Approx. weight 820 – 920 kg/km (use ≈ 870 kg/km) —
Cable shape Round —
7.  Mechanical & Installation Parameters
Parameter Value Note
Minimum bending radius (unarmoured multi-core) ≥ 15 × OD ≈ 357 mm @ Ø23.8 mm —
Max. pulling tension (Cu only) 50 N/mm² × 35 mm² × 4 = 7,000 N total use conductor sock, avoid sheath grip
Direct burial Allowed in non-aggressive soil; for mechanical protection use ZR-YJV22 4×35 —
Conduit ID ≥ 1.5 × OD → ≥ 36 mm (use 40 mm or 50 mm conduit) —
Elevation difference limit None (XLPE) —
8.  Selection Guide — When FR Matters
Scenario Recommended Cable Reason
Flame-retardant, halogenated acceptable (standard) ZR-YJV 4×35 (this cable) Class C FR, PVC sheath, cost-effective
Low-smoke halogen-free required (LSZH) WDZ-YJY 4×35 LSZH sheath — IEC 61034 / IEC 60754 compliant
Fire-survival circuit (circuit integrity) NH-ZR-YJV 4×35 BS 6387 / IEC 60331 fire-survival grade
Heavy mechanical load / direct burial risk ZR-YJV22 4×35 Steel-tape armoured version
Separate PE and N required 5-core version 4×35 has combined/shared PE-N only


7.Cross Section Structure


ZR-YJV 4×35mm² Flame Retardant Copper Power Cable, 0.6/1kV XLPE Insulated PVC Sheath



ZR-YJV 4×35 mm² — Cable Cross-Section Structure (Schematic)
Four-core construction from conductor to outer sheath · nominal values per GB/T 12706.1 / IEC 60502-1 · not to exact scale






No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductor (Cu) × 4 Annealed copper, Class 2 stranded — 7 × 2.52 mm per core (7/2.52), nominal 35 mm² per core — ≈ 7.56 (Ø per core) Current-carrying element; max DC resistance ≤ 0.524 Ω/km @ 20 °C (per core)
2 Insulation (XLPE) × 4 Cross-linked polyethylene 0.9 ≈ 9.36 (Ø per core, over insulation) Dielectric barrier; rated 90 °C continuous; withstands 3.5 kV / 5 min
3 Core lay-up Four insulated cores laid up around central non-hygroscopic filler; binder tape — ≈ 22.6 (Ø over lay-up, calc.) Forms a round assembly for sheathing
4 Outer sheath (PVC) Flame-retardant PVC, ST2 type, black 1.8 ≈ 27.1 (Ø overall) Mechanical & moisture protection; flame retardance ZC (ZR) per GB/T 19666
Key Dimensions & Properties
Overall diameter ≈ 27.1 mm Mingda four-core unarmored table

Approx. cable weight ≈ 1626 kg/km Mingda 1626 (Al ≈ 731.8)

Rated voltage 0.6/1 kV AC 50 Hz; max system voltage Um = 1.2 kV

Max conductor temperature 90 / 250 °C Continuous / short-circuit (≤ 5 s)

Min. bending radius (multi-core) ≥ 15 × OD — OD = actual cable diameter

Flame-retardant class ZC (ZR) — GB/T 19666

Schematic — not to exact scale. Nominal values for reference; confirm against factory test certificate.


Product Structure Introduction — ZR-YJV 4×35 mm²
Four-core layered construction description, from conductor to outer sheath · per GB/T 12706.1 & IEC 60502-1 · CU / XLPE / PVC · 0.6/1 kV
1. General Description
ZR-YJV 4×35 is a 0.6/1 kV AC flame-retarded four-core cable built on the classic copper / XLPE / PVC platform and manufactured to GB/T 12706.1 / IEC 60502-1, with stranding per GB/T 3956 / IEC 60228 and fire classification per GB/T 19666 (ZC default). Approx. outside diameter 27.1 mm and weight 1626 kg/km make it a typical rising-main and feeder cable at this section; it is delivered on 100 m coils or drums.
All four cores share the same 35 mm² section, so the neutral conductor can carry full phase current when required — a practical advantage for lighting and unbalanced single-phase loads.
2. Conductor System
Each core strands seven 2.52 mm annealed copper wires (7/2.52, Class 2) into a round conductor of ≈ 7.56 mm with a maximum DC resistance of 0.524 Ω/km at 20 °C. The stranded cross-section reduces skin-effect loss and keeps the cable flexible enough for switchgear cubicles and riser trunking.
3. Insulation System
XLPE insulation is applied at the 0.9 mm wall maintained through the 25–35 mm² band, bringing each core to ≈ 9.36 mm over insulation. Dielectric properties support a 3.5 kV AC five-minute routine test, continuous operation at 90 °C, and short-circuit peaks of 250 °C for up to five seconds, with volume resistivity ≥ 1×10¹² Ω·cm.
4. Sheath & Fire Performance
The four insulated cores are assembled around a dry central filler into a round bundle of about 22.6 mm and bound with tape, then jacketed with 1.8 mm of flame-retarded ST2 PVC to close at ≈ 27.1 mm. The ZC rating is proven through GB/T 18380.12 single and GB/T 18380.35 class-C bunched burning; because PVC carries halogen, projects demanding smoke/zero-halogen should move to WDZ-YJY.
5. Service Guidance
• Keep installation bends at or above 15 × OD.  • Prove the circuit with the DC 4U0 = 2.4 kV / 15 min test before energising.  • Ambient −20 to +45 °C in service; warm reels for pulls below 0 °C.  • Apply grouping, ambient and burial derating to the quoted ampacity.  • Terminate with lugs and glands sized for the ≈ 7.56 mm core.


8. Verification Plan. Routine: resistance, 3.5 kV/5 min, construction (ins. ≥ 0.9 mm, sheath ≥ 1.8 mm). Sample: XLPE hot-set (200 ± 3 °C / 15 min / 0.2 MPa). Type: flame + bending. Site: DC 4U0 = 2.4 kV / 15 min (Q/GDW 13244.1-2018).


Insulation Test Data
ZR-YJV  0.6/1 kV  4 × 35 mm²  (Cu / XLPE / FR-PVC)
1.  Cable Identification
Item Description Standard / Note
Designation ZR-YJV 0.6/1 kV 4×35 mm² GB/T 12706.1-2020
Conductor Bare annealed copper, Class 2 stranded, 7×∅2.52 mm GB/T 3956 / IEC 60228
Insulation XLPE (cross-linked polyethylene), 0.9 mm nominal GB/T 12706.1-2020
Outer sheath Flame-retardant PVC (ZR grade), 1.8 mm nominal, black GB/T 19666-2019
Rated voltage U₀/U 0.6 / 1 kV (Uₘ = 1.2 kV) IEC 60502-1
Number of cores 4 (three-phase L1+L2+L3+N or L1+L2+L3+PE, equal sizes) —
2.  Insulation Design Data  (CORE)
Parameter Value Remarks
Insulation material XLPE (cross-linked polyethylene) —
Nominal thickness (eₙ) 0.9 mm 35 mm² class
Minimum allowable thickness (e_min) 0.71 mm eₙ − 0.19 mm (GB/T 12706.1-2020, Table 3)
Insulator colours Brown/black/grey/blue or red/yellow/blue/green-yellow (or as specified) IEC 60446
Volume resistivity @ 90 °C ≥ 10¹² Ω·cm —
Dielectric loss factor (tan δ) @ 20 °C ≤ 1 × 10⁻³ reference
Relative permittivity (εᵣ) ≈ 2.3 – 2.5 reference
Long-term service temp. 90 °C GB/T 12706.1-2020
Short-circuit temp. (≤ 5 s) 250 °C IEC 60502-1
Emergency overload temp. 105 – 130 °C transient
Diameter over insulated core 9.3 mm conductor 7.5 + 2×0.9
3.  Thermal Characteristics
Property Value Remarks
Max. conductor operating temp. (normal) 90 °C long-term
Max. conductor temp. — short-circuit (≤ 5 s) 250 °C IEC 60502-1
Emergency overload temp. 105 °C (up to 130 °C transient) —
Min. installation ambient temp. 0 °C (pre-heat below 0 °C) —
Service ambient range (PVC sheath) −15 °C to +90 °C —
Flame retardant class (sheath) Class C (ZR per GB/T 19666) —



4.  Insulation Test Schedule
Test Item Test Value / Condition Result
Routine withstand test (AC) 3.5 kV AC, 5 min — no breakdown PASS
Type test voltage 4.0 kV AC PASS (IEC 60502-1)
Partial discharge test ≤ 10 pC @ 1.73 U₀ (1.73 kV) PASS (XLPE)
Insulation resistance (IR) ≥ 10⁴ MΩ·km @ 20 °C (reference) PASS
Hot-set test (XLPE cross-linking) 200 °C, 15 min, load 0.2 N/mm² — elongation ≤ 175 %, permanent set ≤ 15 % PASS (IEC 60811-507)
Aging test (air oven) 135 °C, 168 h — tensile strength / elongation retained ≥ 80 % PASS
Tensile strength (insulation) ≥ 12.5 MPa (XLPE, before aging) PASS
Elongation at break (insulation) ≥ 200 % (XLPE, before aging) PASS
Cold bend test −15 °C, 4 h — no cracking PASS
Water absorption ≤ 1 mg/cm² (85 °C, 336 h, reference) PASS
Breakdown voltage (insulation) ≥ 20 kV/mm (reference) PASS
DC resistance of conductor @ 20 °C ≤ 0.524 Ω/km (Class 2 Cu, per core) PASS (GB/T 3956)
Dielectric loss (tan δ) measurement ≤ 1 × 10⁻³ @ 20 °C PASS (reference)
Spark test (during production) 6 – 10 kV (online), pinhole detection PASS
Thickness measurement (microscopic) eₙ = 0.9 mm; e_min ≥ 0.71 mm PASS
5.  Electrical Parameters
Parameter Value Note
Rated voltage U₀/U 0.6 / 1 kV Uₘ = 1.2 kV
Test voltage AC (5 min, routine) 3.5 kV IEC 60502-1
Type-test voltage 4.0 kV IEC 60502-1
DC resistance @ 20 °C (per core) ≤ 0.524 Ω/km GB/T 3956 / IEC 60228, Class 2 max
AC resistance @ 90 °C (est.) ≈ 0.681 Ω/km per core
Current rating — in air (30 °C, single circuit) ≈ 95–108 A (design ≈ 102 A) 4-core
Current rating — direct buried (20 °C, soil 1.0 K·m/W, 0.7 m) ≈ 118–132 A (design ≈ 125 A) 4-core
Short-circuit current (1 s, Cu, 250 °C, per core) ≈ 3.50 kA reference
Frequency 50/60 Hz AC —
6.  Dimensional / Inspection Result
Item Design / Limit Measured (example)
Conductor construction Class 2, 7×∅2.52 mm 7×2.52 mm
Conductor diameter ≈ 7.5 mm 7.4 mm
Insulation thickness (each core) 0.9 mm (min. 0.71 mm) 0.92 / 0.90 / 0.91 / 0.89 mm
Diameter over insulated core 9.3 mm 9.2 mm
Sheath thickness 1.8 mm (min. 1.5 mm) 1.81 mm
Overall cable diameter 23.0 – 24.5 mm (design 23.8) 23.7 mm
DC resistance @ 20 °C (per core) ≤ 0.524 Ω/km 0.518 Ω/km
Approx. weight 820 – 920 kg/km (≈ 870) 868 kg/km
Footnotes
1. All tests performed at ambient 20 ± 5 °C and 45–75 % RH unless otherwise stated.
2. Routine tests: withstand (3.5 kV / 5 min), conductor resistance, dimensional check. Type tests: 4.0 kV, partial discharge, hot-set, aging, mechanical (per IEC 60502-1).
3. Test values marked “reference” are typical design values — confirm against manufacturer test report / GB/T 12706.1-2020.
4. Insulation thickness for 35 mm² class = 0.9 mm nominal (GB/T 12706.1-2020, Table 3); minimum = 0.9 − 0.19 = 0.71 mm.
5. For low-smoke halogen-free → use WDZ-YJY 4×35; for fire-survival → NH-ZR-YJV 4×35; for armoured → ZR-YJV22 4×35.


9. Usage Cautions. Bend ≥ 15 × OD; pull by stocking, never by the conductor; avoid tight saddles; protect from sun/impact; run the DC site test before energising; derate for ambient/grouping/burial; size lugs for the ≈ 7.56 mm core.


ZR-YJV 4×35mm² Flame Retardant Copper Power Cable, 0.6/1kV XLPE Insulated PVC Sheath


10. Application Range. Three-phase + neutral mains, sub-distribution, switchgear and motor feeders at 0.6/1 kV — building risers, plant rooms, pump/HVAC circuits — in conduit, tray, trench, duct, trunking; indoor or sheltered outdoor.


ZR-YJV 4×35mm² Flame Retardant Copper Power Cable, 0.6/1kV XLPE Insulated PVC Sheath


11. Ordering. ZR-YJV 0.6/1 kV 4×35 + length/drum type + marking. Standard 100 m; confirm against the factory test certificate.


ZR-YJV 4×35mm² Flame Retardant Copper Power Cable, 0.6/1kV XLPE Insulated PVC Sheath