Copper Conductor Flame Retardant XLPE Cable ZR-YJV 3×95mm²+1×50mm² for Site Power Wiring
Product Summary
Product Details
xlpe cable zr-yjv
,copper xlpe cable
,copper 4 cores cable
Product Description
Copper Conductor Flame Retardant XLPE Cable ZR-YJV 3×95mm²+1×50mm² for Site Power Wiring
Cable Designation & Meaning
|
Code |
Meaning |
|---|---|
|
ZC |
Flame retardant Class C |
|
YJ |
Cross-linked polyethylene (XLPE) insulation |
|
V |
Polyvinyl chloride (PVC) sheath |
|
3×95 mm² + 1×50 mm² |
Three phase cores of 95 mm² + one neutral core of 50 mm² copper conductor |
Construction: Three 95 mm² copper conductors (phase) + one 50 mm² copper conductor (neutral), XLPE insulation, PVC outer sheath. No metallic screen/armour as standard (can be added on request).

ZC-YJV 3×95+1×50 mm² — LV Flame-Retardant 3+1 Power Cable — Specification
1. Overview & Ratings. ZC-YJV 3×95+1×50 is a 3+1 LV sub-main equipment feeder cable rated 0.6/1 kV (Um 1.2), 90 °C working, ZC class C PVC sheath: three 95 mm² compacted copper phase cores plus a reduced 50 mm² neutral, dry-cured XLPE, unarmored. OD ≈ 28 mm, ≈ 3200 kg/km (est.), ≈ 200 A per phase free air at 30 °C (est.). Scope: building sub-mains, machine tools, HVAC chillers/compressors, pump stations and light-industry branches — not 950°C fire duty.
2. Construction Stack (Inner → Outer, expanded).
| Layer / Feature | Build | Function |
|---|---|---|
| Phase conductors L1/L2/L3 | 3×95 compacted Cu, Class 2, ≈19 strands | R ≤0.206 Ω/km |
| Neutral N | 1×50 compacted Cu, Class 2, ≈19 strands | R ≤0.387 Ω/km |
| Strand compaction | Concentric layers rolled compact per core | Compact round bundle, clean lugs |
| XLPE phase insulation | Dry-cured PE, ≈2.0 mm | Uniform 90°C dielectric |
| XLPE neutral insulation | Dry-cured PE, ≈1.8 mm | Matched to neutral voltage class |
| 3+1 core laying | Three phases around the center neutral | Round finished bundle |
| PVC ZC sheath | Class C, ≈2.0 mm overall | Self-extinguishes, prints clear |
3. Electrical Characteristics. Phase R ≤ 0.206 Ω/km, neutral R ≤ 0.387 Ω/km @20 °C. Test 3.5 kV AC / 5 min; ≈ 200 A per phase (est., air 30 °C); short-circuit ≈ 11 kA / 1 s (est.); 50/60 Hz; unscreened; low-loss XLPE; high stable insulation resistance.
Insulation & Sheath Data
|
Property |
Value |
|---|---|
|
Insulation material |
XLPE (cross-linked polyethylene) |
|
Outer sheath material |
PVC (ST₂) |
|
Long-term service temp. |
90 °C (continuous) |
|
Max. conductor temp. (normal) |
90 °C |
|
Short-circuit temp. (≤5 s) |
250 °C |
|
Emergency overload temp. |
130 °C (≤1 h) |
|
Test voltage AC (5 min) |
3.5 kV |
|
Dielectric strength |
≥ 20 kV/mm |
|
Volume resistivity @20 °C |
≥ 1×10¹⁴ Ω·cm |
|
Shield |
None as standard (can be added) |
Electrical Parameters
|
Parameter |
Value |
Note |
|---|---|---|
|
Rated voltage U₀/U |
0.6 / 1 kV |
GB/T 12706.1 / IEC 60502-1 |
|
Max. system voltage |
1.2 kV AC |
— |
|
Test voltage AC (5 min) |
3.5 kV |
Routine test |
|
DC resistance @20 °C (phase) |
≤ 0.193 Ω/km per core |
GB/T 3956 Class 2 Cu max (95 mm²) |
|
DC resistance @20 °C (neutral) |
≤ 0.387 Ω/km per core |
GB/T 3956 Class 2 Cu max (50 mm²) |
|
AC resistance @90 °C (est., phase) |
≈ 0.247 Ω/km per core |
— |
|
AC resistance @90 °C (est., neutral) |
≈ 0.496 Ω/km per core |
— |
|
Current rating in air (30 °C) |
3-phase: 245 A |
3×95+1×50, touching, in free air |
|
Current rating in tray (30 °C) |
3-phase: 270 A |
3×95+1×50, spaced 2×OD |
|
Current rating buried in ground (20 °C, thermal resistivity 1.2 K·m/W) |
3-phase: 255 A |
direct buried |
|
Current rating in conduit (30 °C) |
3-phase: 220 A |
— |
|
Short-circuit current (1 s, Cu, 250 °C, phase) |
≈ 10.5 kA (10,450 A) per core |
— |
|
Short-circuit current (1 s, Cu, 250 °C, neutral) |
≈ 5.5 kA (5,500 A) per core |
— |
|
Capacitance (core-to-sheath, approx.) |
≈ 0.22 µF/km |
XLPE |
|
Inductive reactance (approx.) |
≈ 0.08 Ω/km |
at 50 Hz |
|
Frequency |
50/60 Hz AC |
— |
Reference values: 3×95+1×50 at 245 A three-phase, 400 V → max load ≈ 147 kW (cos φ = 0.8). Suitable for large three-phase distribution with reduced neutral, industrial motors, and building sub-main feeders.
4. Thermal & Flame. 90 °C continuous, 250 °C short-time; ZC class C self-extinguishing — flame retardancy, not 950°C integrity; survives equipment start-stop cycling; indoor preferred, UV jacket optional.
Temperature Characteristics
|
Property |
Value |
|---|---|
|
Max. conductor operating temp. |
90 °C (continuous) |
|
Max. short-circuit temp. (≤5 s) |
250 °C |
|
Emergency overload temp. |
130 °C (≤1 h) |
|
Min. installation ambient temp. |
0 °C (below 0 °C requires preheating) |
|
Service ambient range |
−20 °C to +90 °C |
|
Flexing temp. range |
0 °C to +90 °C |
Fire Performance (ZC-YJV — Flame Retardant C)
|
Property |
Value / Requirement |
|---|---|
|
Flame retardant |
GB/T 18380.12 / IEC 60332-1-2 (single cable, self-extinguishing) |
|
Flame retardant class |
Class C (ZC) per GB/T 19666 |
|
Halogen content |
Contains halogen (PVC sheath) |
|
Smoke density |
Not low-smoke (PVC) |
|
Corrosivity |
Corrosive (PVC) |
|
Toxicity |
Toxic fumes when burned (PVC) |
|
EMI shielding |
None (no metallic screen/armour) |
5. Installation Practice & Handling. Hydraulic crimp 95 mm² phase lugs and a 50 mm² neutral lug, glands to ≈28 mm OD, torque per table; bend ≥ 15×OD ≈ 420 mm; apply conduit/tray derating; keep the bundle round; verify three-phase continuity, phase sequence, neutral and insulation before energizing.
Mechanical & Installation Parameters
|
Parameter |
Value |
Remarks |
|---|---|---|
|
Minimum bending radius |
≥ 15 × OD → ≈ 480 mm at Ø32.0 mm |
four-core unarmoured |
|
Max. pulling tension (phase) |
1,425 N per core (95 mm² × 15 N/mm²) |
Cu conductor limit |
|
Max. pulling tension (neutral) |
750 N per core (50 mm² × 15 N/mm²) |
Cu conductor limit |
|
Direct burial |
Suitable (with sand bedding) |
— |
|
Surface mounting |
Heavy-duty cable tray, ladder, cleats |
— |
|
Conduit ID |
≥ 65 mm |
— |
|
Fixing |
heavy-duty cleats, cable ties |
— |
|
Impact resistance |
Moderate |
— |
|
Water resistance |
Good (PVC sheath) |
— |
|
UV resistance |
Fair (PVC degrades outdoors, use UV-resistant PVC or conduit) |
— |
|
Flex life |
Good (Class 2 stranded) |
fixed installation |
|
Termination note |
Standard compression lugs or mechanical connectors |
— |
6. Typical Service Applications. Building sub-mains, machine tools, HVAC chillers and compressors, pump stations, and commercial light-industry branch circuits.

7. Testing & QA Regime (16 items). Routine: phase and neutral DC resistance, 3.5 kV withstand, insulation resistance, continuity, phase/neutral insulation thickness, sheath thickness, dimensional check, strand construction, eccentricity, print legibility, mass, packing inspection. Type: ZC flame test, short-circuit rating, sheath mechanical.
Cable Parameters
| ZR-YJV 3×95+1×50 mm² — Flame-Retardant 3+1-Core Power Cable (0.6/1 kV) · Comprehensive Parameter Sheet | ||||
| Copper conductor · XLPE insulation · PVC sheath · 3 phase cores @ 95 mm² + 1 neutral core @ 50 mm² · conforms to GB/T 12706.1, IEC 60502-1, GB/T 3956, GB/T 19666 · primary data from Zhongce 3+1 table | ||||
| Code | Parameter | Value | Unit | Remarks |
| 01 · Identification | ||||
| Ref: GB/T 12706.1 / IEC 60502-1; fire class GB/T 19666; Um = 1.2 kV; 50 Hz | ||||
| 1-A | Product designation | Copper-conductor XLPE-insulated PVC-sheathed flame-retardant power cable, 3+1 core | — | ZR-YJV series; PVC sheath contains halogen |
| 1-B | Type reference | ZR-YJV 3×95+1×50 | — | Three 95 mm² phase cores + one 50 mm² neutral core |
| 1-C | Applicable standards | GB/T 12706.1; IEC 60502-1 | — | Conductor per GB/T 3956 |
| 1-D | Voltage rating U0/U | 0.6/1 | kV | Highest voltage for equipment Um = 1.2 kV; AC 50 Hz |
| 1-E | Core layout | Three phase cores (L1/L2/L3) surrounding a central neutral core (N) | — | Three-phase four-wire (TN-C) configuration |
| 1-F | Nominal conductor areas | 3 × 95 (phase) + 1 × 50 (neutral) | mm² | Phase cores carry line current; neutral per GB/T 12706.1 |
| 1-G | Fire performance level | Class C (ZC) — standard for "ZR" marking | — | ZA/ZB available on request |
| 1-H | Dielectric system | XLPE insulation / PVC sheath (ST2) | — | 90 °C XLPE class; flame-retarded PVC jacket |
| 02 · Conductor | ||||
| Ref: GB/T 3956 / IEC 60228 Class 2 — phase 95 mm² = 19 wires; neutral 50 mm² = 7 wires | ||||
| 2-A | Conductor material | Annealed electrolytic copper (high conductivity) | — | ≥ 97% IACS conductivity |
| 2-B | Stranding class | Class 2 (compact stranded) | — | GB/T 3956 / IEC 60228 |
| 2-C | Phase stranding (×3) | 19 × 2.52 mm (19/2.52) each | — | 1+6+12 concentric rings; nominal 95 mm² |
| 2-D | Neutral stranding (×1) | 7 × 3.00 mm (7/3.00) | — | 1+6 concentric rings; nominal 50 mm² |
| 2-E | Phase conductor diameter | ≈ 12.6 | mm | Per phase core (19 × 2.52) |
| 2-F | Neutral conductor diameter | ≈ 9.0 | mm | Neutral core (7 × 3.00) |
| 2-G | Phase DC resistance @ 20 °C | 0.193 | Ω/km | GB/T 3956 Class 2 Cu (95 mm²) |
| 2-H | Neutral DC resistance @ 20 °C | 0.387 | Ω/km | GB/T 3956 Class 2 Cu (50 mm²) |
| 2-I | Phase conductor mass | ≈ 845 | kg/km per core | 95 mm² × 8.89 g/cm³ (est.) |
| 2-J | Neutral conductor mass | ≈ 445 | kg/km | 50 mm² × 8.89 g/cm³ (est.) |
| 03 · Insulation | ||||
| Ref: Zhongce 3+1 table — phase 1.1 mm (95 mm²); neutral 1.0 mm (50 mm²) | ||||
| 3-A | Dielectric material | Cross-linked polyethylene (XLPE) | — | Chemically cross-linked during extrusion |
| 3-B | Phase insulation thickness | 1.1 | mm | Zhongce 3+1 table for 95 mm² |
| 3-C | Neutral insulation thickness | 1.0 | mm | Zhongce 3+1 table for 50 mm² |
| 3-D | Diameter over phase insulation | ≈ 14.8 | mm | Per phase core (calculated) |
| 3-E | Diameter over neutral insulation | ≈ 11.0 | mm | Neutral core (calculated) |
| 3-F | Insulation mass (total) | ≈ 275 | kg/km | 3 phase + 1 neutral, density 0.92 g/cm³ (est.) |
| 3-G | XLPE tensile strength | ≥ 12.5 | MPa | GB/T 12706.1 / GB/T 2951 |
| 3-H | XLPE elongation at break | ≥ 200 | % | GB/T 12706.1 / GB/T 2951 |
| 04 · Assembly | ||||
| Ref: 3+1 cabling — neutral at centre, three phase cores around; round bundle | ||||
| 4-A | Lay-up configuration | Central neutral core + three phase cores in triangular ring + non-hygroscopic filler + binder tape | — | Forms round, stable cable bundle |
| 4-B | Filler material | Polypropylene (PP) rope / non-hygroscopic filler | — | Maintains roundness; water-resistant |
| 4-C | Binder tape | Polyester tape, single helical wrap | — | Secures cores during sheathing |
| 4-D | Lay ratio (typical) | 12 : 1 to 16 : 1 | — | Cabling pitch / assembly diameter |
| 4-E | Diameter over cabled assembly | ≈ 29.8 | mm | Derived: Zhongce Ø 34.8 − 2 × 2.5 sheath |
| 05 · Sheath | ||||
| Ref: Zhongce 3+1 table (Ø 34.8; 3718 kg/km; sheath 2.5 mm) | ||||
| 5-A | Jacket material | Flame-retardant PVC, ST2 compound | — | Black standard; other colours on request |
| 5-B | Nominal sheath thickness | 2.5 | mm | Zhongce 3+1 table |
| 5-C | Overall finished diameter | ≈ 34.8 | mm | Zhongce 3+1 unarmored table |
| 5-D | Approximate cable mass | ≈ 3718 | kg/km | Zhongce copper-conductor figure |
| 5-E | Sheath colour | Black (standard) | — | Custom colours available |
| 5-F | PVC tensile strength | ≥ 10.0 | MPa | GB/T 12706.1 / GB/T 2951 |
| 5-G | PVC elongation at break | ≥ 125 | % | GB/T 12706.1 / GB/T 2951 |
| 5-H | PVC thermal stability | ≥ 200 | min | 200 °C Congo-red test (GB/T 2951) |
| 06 · Electrical | ||||
| Ref: Zhongce 3+1 table (air 320 / buried 315 A Cu @ 25–30 °C) | ||||
| 6-A | Phase conductor DC resistance | 0.193 | Ω/km | GB/T 3956 @ 20 °C, each phase |
| 6-B | Neutral conductor DC resistance | 0.387 | Ω/km | GB/T 3956 @ 20 °C, neutral |
| 6-C | Routine voltage proof | 3.5 kV AC / 5 min | — | No breakdown; 50 Hz sine wave |
| 6-D | Insulation resistance (finished) | ≥ 36.7 | MΩ·km | @ 20 °C on completed cable |
| 6-E | XLPE volume resistivity | ≥ 1 × 10¹² | Ω·cm | Material-level property |
| 6-F | Capacitance (typical) | ≤ 0.38 | μF/km | Per phase core to earth/neutral (est.) |
| 6-G | Inductance (typical) | ≈ 0.26 | mH/km | Three-core cable, 50 Hz (est.) |
| 6-H | AC impedance @ 50 Hz | ≈ 0.20 | Ω/km | √(R² + X²); R-dominant (est.) |
| 6-I | Short-circuit current (1 s) | ≈ 10.9 | kA | I = k·A/√t, k=115 for Cu/XLPE (est.) |
| 6-J | Buried ampacity @ 25 °C | ≈ 315 | A | Zhongce basis; Cu, 3 phase loaded |
| 6-K | Air ampacity @ 30 °C | ≈ 320 | A | Zhongce basis; Cu, 3 phase loaded |
| 6-L | Earth-fault loop impedance | Per project calculation | — | Depends on cable length & upstream system |
| 07 · Thermal | ||||
| Ref: XLPE class per GB/T 12706.1 / IEC 60502-1 | ||||
| 7-A | Continuous conductor temperature | 90 | °C | XLPE insulation class rating |
| 7-B | Short-circuit temperature (≤ 5 s) | 250 | °C | GB/T 12706.1 / IEC 60502-1 |
| 7-C | Ambient operating range | -20 to +45 | °C | Per manufacturer datasheet family |
| 7-D | Minimum installation temperature | 0 | °C | Pre-heat drums if colder than 0 °C |
| 7-E | Maximum soil temperature (direct burial) | 25 | °C | Reference for buried ampacity |
| 7-F | Thermal resistance (insulation+sheath) | ≈ 3.2 | K·m/W | Typical for XLPE/PVC 0.6/1 kV (est.) |
| 08 · Fire (ZR) | ||||
| Ref: GB/T 19666; GB/T 18380.12; GB/T 18380.35 (20 min, ≥ 1.5 L/m) | ||||
| 8-A | Flame-retardant grade | Class C (ZC) — default for "ZR" | — | PVC sheath is halogen-containing |
| 8-B | Single-cable vertical flame test | Compliant | — | Method per GB/T 18380.12 |
| 8-C | Bunched-cable flame test — C | Char height ≤ 2.5 m | — | Method per GB/T 18380.35 |
| 8-D | Halogen status | Halogenated (not LSZH) | — | Use WDZ-YJY for low-smoke zero-halogen |
| 8-E | Smoke density (PVC) | Higher than LSZH | — | PVC emits smoke under fire |
| 8-F | Oxygen index (FR-PVC) | ≥ 28 | % | Typical flame-retardant PVC compound (est.) |
| 09 · Installation | ||||
| Ref: Q/GDW 13244.1-2018; GB 50168 | ||||
| 9-A | Minimum bending radius (multi-core) | ≥ 15 × actual OD | — | ≈ 522 mm for Ø 34.8 mm |
| 9-B | Approved laying methods | Conduit, tray, trench, duct, trunking, direct burial | — | Mechanical protection required for direct burial |
| 9-C | Post-install commissioning test | DC 4U0 = 2.4 kV / 15 min | — | Per Q/GDW 13244.1-2018 |
| 9-D | Maximum pulling tension | ≤ 4000 | N | Rule of thumb: 40 N/mm² of conductor area (est.) |
| 9-E | Storage conditions | Dry, covered, −20 to +45 °C | — | Avoid direct sunlight and moisture |
| 9-F | Cold-weather pre-heating | Warm to ≥ 0 °C before pulling | — | Prevents jacket cracking |
| 10 · Packing | ||||
| Ref: custom lengths; marking per GB/T 6995 / project spec | ||||
| 10-A | Standard supply length | 100 m per coil or wooden drum | — | Custom lengths available on request |
| 10-B | Cable surface marking | Type, voltage, manufacturer, year, metre marks | — | Per GB/T 6995 and project requirements |
| 10-C | Recommended drum size | ≥ Ø 1400 mm flange | — | For 100 m of Ø 34.8 mm cable (est.) |
| 10-D | Approx. net weight per 100 m drum | ≈ 372 | kg | 100 m × 3718 kg/km |
Cable Test Parameters
| ZR-YJV 3×95+1×50 mm² — Test & Verification Schedule (GB/T 12706.1 & IEC 60502-1) | ||||
| Stage | Test Item | Method / Standard | Acceptance Criterion | Notes |
| Routine | Phase conductor DC resistance | GB/T 3956 (IEC 60228) | ≤ 0.193 Ω/km @ 20 °C (95 mm²) | Every production length |
| Routine | Neutral conductor DC resistance | GB/T 3956 (IEC 60228) | ≤ 0.387 Ω/km @ 20 °C (50 mm²) | Every production length |
| Routine | Power-frequency withstand | GB/T 12706.1 / IEC 60502-1 | 3.5 kV AC / 5 min, no breakdown | Conductor to earth/water bath |
| Routine | Dimensional inspection | GB/T 2951 | Phase ins. ≥ 1.1 mm; neutral ins. ≥ 1.0 mm; sheath ≥ 2.5 mm; OD within tolerance | Wall & diameter check |
| Routine | Conductor continuity | Visual / electrical | All cores continuous, no break | Every length |
| Sample | XLPE hot-set test | GB/T 12706.1 §16.3.13 / GB/T 2951.11 | 200 ± 3 °C, 15 min, 0.2 MPa: load elongation ≤ 175 %; permanent ≤ 15 % | Cross-linking verification |
| Sample | XLPE tensile & elongation | GB/T 2951 | Tensile ≥ 12.5 MPa; elongation ≥ 200 % | Aged and unaged |
| Sample | PVC sheath tensile & elongation | GB/T 2951 | Tensile ≥ 10.0 MPa; elongation ≥ 125 % | Aged and unaged |
| Sample | PVC thermal stability | GB/T 2951 (Congo-red) | ≥ 200 min @ 200 °C | HCI evolution test |
| Sample | Conductor geometry | GB/T 3956 | Phase: 19 × 2.52 mm Ø ≈ 12.6; neutral: 7 × 3.00 mm Ø ≈ 9.0 | Per batch |
| Type | Single-cable flame test | GB/T 18380.12 | No flame to upper reference mark | ZR property |
| Type | Bunched flame test — C | GB/T 18380.35 | Char ≤ 2.5 m; 20 min; ≥ 1.5 L/m | Class C compliance |
| Type | Bending test | GB/T 12706.1 | No damage on specified mandrel | Multi-core bending rule |
| Type | Insulation resistance | Factory method | ≥ 36.7 MΩ·km @ 20 °C | Not routine under GB/T 12706.1 |
| Post-install | DC withstand commissioning | Q/GDW 13244.1-2018 | 2.4 kV DC / 15 min, no breakdown | Required for new installations |
| Post-install | Phase identification | Visual / continuity | L1/L2/L3/N correctly labelled at both ends | Before energisation |
Cable Cross Section Structure

| ZR-YJV 3×95+1×50 mm² — Cross-Section Construction Diagram (Schematic) | |||||
| Layered 3+1 conductor build-up from copper strand to PVC jacket · nominal dimensions per GB/T 12706.1 / IEC 60502-1 · primary data from Zhongce 3+1 table | |||||
| No. | Layer | Material / Construction | Nominal Thickness (mm) | Diameter (mm) | Function / Remarks |
| 1 | Phase conductor (Cu) × 3 | Annealed copper, Class 2 compact strand — 19 wires of 2.52 mm per core (19/2.52, 1+6+12 layout), nominal area 95 mm² each | — | ≈ 12.6 (Ø each phase core) | Line-current carrying phase conductors; DC resistance capped at 0.193 Ω/km at 20 °C |
| 2 | Neutral conductor (Cu) × 1 | Annealed copper, Class 2 compact strand — 7 wires of 3.00 mm (7/3.00, 1+6 layout), nominal area 50 mm² | — | ≈ 9.0 (Ø neutral core) | Return / neutral path; DC resistance capped at 0.387 Ω/km at 20 °C |
| 3 | Phase insulation (XLPE) × 3 | Cross-linked polyethylene dielectric | 1.1 | ≈ 14.8 (Ø each phase core, incl. insulation) | Electrical isolation; 90 °C continuous rating; withstands 3.5 kV for 5 min |
| 4 | Neutral insulation (XLPE) × 1 | Cross-linked polyethylene dielectric | 1 | ≈ 11.0 (Ø neutral core, incl. insulation) | Electrical isolation for the neutral conductor |
| 5 | Core assembly | Neutral core at centre + three phase cores cabled around + PP filler + polyester binder tape | — | ≈ 29.8 (Ø over assembled cores) | 3+1 configuration; derived from Zhongce OD − 2×sheath |
| 6 | Outer jacket (PVC) | Flame-retardant PVC, ST2 compound, black | 2.5 | ≈ 34.8 (Ø finished cable, Zhongce) | Mechanical and moisture protection; ZC flame retardance per GB/T 19666 |
| Key Dimensions & Properties (expanded) | |||||
| Finished cable diameter | ≈ 34.8 | mm | Zhongce 3+1 unarmored table | ||
| Approximate cable mass | ≈ 3718 | kg/km | Zhongce copper-conductor figure | ||
| Nominal voltage rating | 0.6/1 | kV | AC 50 Hz; maximum system voltage Um = 1.2 kV | ||
| Conductor temperature limits | 90 / 250 | °C | Continuous service / short-circuit (≤ 5 s) | ||
| Minimum bend radius (multi-core) | ≥ 15 × OD ≈ 522 | mm | OD = actual finished cable diameter | ||
| Flame-retardant classification | ZC (ZR) | — | Per GB/T 19666 | ||
| Short-circuit current (1 s) | ≈ 10.9 | kA | I = k·A/√t, k=115 for Cu/XLPE (est.) | ||
| AC impedance @ 50 Hz | ≈ 0.20 | Ω/km | √(R² + X²); R-dominant (est.) | ||
| Capacitance (typical) | ≤ 0.38 | μF/km | Per phase core (est.) | ||
| Inductance (typical) | ≈ 0.26 | mH/km | Three-core cable (est.) | ||
| Air ampacity @ 30 °C | ≈ 320 | A | Zhongce basis; Cu, 3 phase loaded | ||
| Buried ampacity @ 25 °C | ≈ 315 | A | Zhongce basis; Cu, 3 phase loaded | ||
| Schematic — not to exact scale. Primary data (OD, weight, ampacity) from Zhongce 3+1 table; conductor/insulation diameters calculated from GB/T 3956 and GB/T 12706.1. Values marked (est.) are engineering estimates. | |||||
Construction Description
| Construction Description — ZR-YJV 3×95mm²+1×50 mm² | |||
| Layer-by-layer build-up narrative, conductor through outer jacket · per GB/T 12706.1 & IEC 60502-1 · CU / XLPE / PVC · 0.6/1 kV class · primary data from Zhongce 3+1 table | |||
| 1. Product Identity & Ratings | |||
| ZR-YJV 3×95+1×50 is a heavy-duty flame-retardant 3+1-core cable: it combines three 95 mm² copper phase conductors with a single 50 mm² copper neutral conductor, all insulated in XLPE and enclosed in one ST2 PVC jacket, for 0.6/1 kV service. Manufacturing and type testing follow GB/T 12706.1 / IEC 60502-1, conductor stranding follows GB/T 3956, and the ZR marking corresponds to class ZC under GB/T 19666. The finished cable measures 34.8 mm across (Zhongce 3+1 table) and weighs 3718 kg per kilometre; supply is in 100 m coils or wooden drums. | |||
| This 3+1 build follows the conventional three-phase four-wire format: the reduced neutral core sits in the centre while the three phase cores are laid up around it. With all three phase cores energised, the cable supports 320 A in free air at 30 °C and 315 A when directly buried at 25 °C (Zhongce basis) — suited to main distribution risers, transformer secondaries and large industrial feeders. | |||
| 2. Copper Stranded Conductors | |||
| Each 95 mm² phase core is formed from nineteen 2.52 mm annealed wires in the 1+6+12 compact arrangement (19/2.52) — the Class 2 standard for this cross-section — yielding an outside diameter of about 12.6 mm and a DC resistance ceiling of 0.193 Ω/km at 20 °C. The 50 mm² neutral core uses seven 3.00 mm wires (7/3.00) to about 9.0 mm Ø, with resistance capped at 0.387 Ω/km. Both are compact Class 2 strands that deliver clean circular profiles and dependable crimp terminations; the 19-wire phase construction provides good flexibility for this large section. | |||
| 3. XLPE Dielectric Insulation | |||
| XLPE is extruded at 1.1 mm onto the phase cores (the wall Zhongce's 3+1 table assigns to 95 mm² conductors) and at 1.0 mm onto the 50 mm² neutral core — producing approximately 14.8 mm per phase core and 11.0 mm for the neutral core over the insulation. The dielectric is rated for 90 °C continuous duty and 250 °C for five seconds, maintains volume resistivity above 1×10¹² Ω·cm, passes the routine 3.5 kV AC five-minute voltage proof, and offers tensile strength ≥ 12.5 MPa with elongation ≥ 200 %. | |||
| 4. Cabling & PVC Outer Jacket | |||
| After insulation, the neutral core is placed at the centre and the three phase cores are cabled around it in a triangular ring with polypropylene filler and a polyester binder tape, forming a bundle of about 29.8 mm diameter (derived from the finished OD). A 2.5 mm layer of flame-retarded ST2 PVC is then extruded over the assembly to the Zhongce 34.8 mm finish. The jacket provides ZC behaviour through GB/T 18380.12 and GB/T 18380.35, offers tensile strength ≥ 10 MPa and elongation ≥ 125 %; because PVC is halogenated, low-smoke zero-halogen projects should specify WDZ-YJY instead. | |||
| 5. Site Handling & Operational Notes | |||
| • Observe the 15 × OD minimum bending radius (≈ 522 mm). • Perform the DC 4U0 = 2.4 kV / 15 min commissioning test before first energisation. • Service ambient spans −20 to +45 °C; warm drums below 0 °C before pulling. • Derate the 320 A (air) / 315 A (buried) references for ambient temperature, grouping and soil conditions. • Maximum pulling tension ≤ 4000 N; use appropriate pulling grips and lubricant. • Select lugs and glands matched to the 12.6 mm phase core, 9.0 mm neutral core and 34.8 mm jacket diameter. • Short-circuit rating ≈ 10.9 kA for 1 second — verify against protective device settings. |
8. Factory Advantages.
- Balanced 3+1 feeder sizing — reduced 50 neutral avoids excess copper cost on balanced equipment loads.
- Stable XLPE cure — even cross-linking keeps the 90°C dielectric consistent under feeder load.
- Dosed ZC compound — self-extinguishing jacket protects distribution rooms and wiring spaces.
- Length-on-demand — cut to exact feeder meter with sealed ends.
- Dual-section resistance log — phase 95 and neutral 50 R recorded to lot for traceability.
- Continuous print line — type, size, ZC, voltage and length readable along feeder runs.
- Phase-color option — L1/L2/L3/N colors reduce wiring errors at distribution boards.
- Drum pack — wound on a rated drum with moisture-sealed ends.
- Certified QA pack — routine + type test record shipped per batch for commissioning.

9. Packaging, Storage & Logistics. Cut to measured feeder length on a wooden drum with sealed ends; continuous marking; store dry indoor on drum supports, shaded, avoid direct UV.

10. Procurement Specification. State "ZC-YJV 3×95+1×50", length, class C, phase colors; note the reduced neutral suits balanced loads (enlarge for high harmonics) and not fire-rated; request the dual-section resistance log and 16-item QA record. Est. values confirmed against the factory certificate.
11. Cable Industry FAQ.
- Q1: How does 3×95+1×50 differ from 4×70? Different architecture: a 3+1 变截面 (reduced-neutral) build rather than four equal cores — phases 95 vs 70 mm², neutral 50 vs 70; phase R 0.206 vs 0.268 Ω/km, phase current ≈200 vs 175 A; aimed at building sub-mains and equipment feeders rather than a balanced four-core branch.
- Q2: Why a 50 mm² neutral here? Balanced motor/equipment loads draw little neutral current; a reduced neutral saves copper. Enlarge it where VFD/rectifier harmonics are high.
- Q3: Is ZC fire-resistant? No. Class C self-extinguishes; it does not hold live at 950°C/180min.
- Q4: DC resistance values? 95 phases ≤0.206; 50 neutral ≤0.387 Ω/km at 20°C.
- Q5: Screen or armor? Unscreened standard; add braid near VFD EMI; steel-tape armor for buried ground-crushing duty.
- Q6: Current per phase? ≈200 A (est.) free air 30°C; derate in crowded conduit and trays.
- Q7: Bending? ≈420 mm (15×OD); standard pulling tools suffice on this section.
- Q8: Connectors? 95 mm² phase lugs and a 50 mm² neutral lug; gland to ≈28 mm OD.
- Q9: Indoor or outdoor? Indoor preferred; specify UV-stabilized jacket for exposed runs.
- Q10: Packing? Wooden drum with moisture-sealed ends.
- Q11: What proof ships? Dual-section resistance log + 16-test record; est. values confirmed against certificate.