"1 electrical building wires pvc or lszh low smoke zero halogen"
- 70 Items Found
Fire Alarm Multi Core Cable 5 Core 1.5m2 RVV For Emergency System
Fire Alarm Multi Core Cable 5 Core 1.5mm² RVV for Emergency System Cable Designation & Meaning Code Meaning RVV R = Flexible copper conductor (Class 5), V = PVC insulation, V = PVC sheath 300/500 V Rated voltage U₀/U = 300/500 V; Uₘ = 500 V 5×1.5 mm² Five flexible cores, each 1.5 mm² copper ...
OEM 4 Core Flexible Cable 4x10mm2+1x6mm2 RVV For Three Phase Earth Power Supply
4 Core + Earth Cable 4x10mm²+1x6mm² RVV for Three Phase + Earth Supply Cable Designation & Meaning Code Meaning R Flexible conductor V PVC insulation V PVC sheath 4×10 mm² Four cores of 10 mm² copper conductor (typically 3×L + 1×N) +1×6 mm² One core of 6 mm² copper conductor (typically reduced ...
ZR-YJV 3x240mm²+1x120mm² XLPE Copper Cable 0.6/1kV Flame Retardant
ZR-YJV 3x240mm²+1x120mm² XLPE Copper Cable 0.6/1kV Flame Retardant Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 3×240 mm² + 1×120 mm² Three phase cores of 240 mm² + one neutral core of 120 mm² ...
Power 4 Core Flexible Cable 2 Core 6.0mm2 RVV For Water Heater Circuit
Flexible Power Cable 2 Core 6.0mm² RVV-2*6.0mm² for Water Heater Circuit Cable Designation & Meaning Code Meaning R Flexible conductor V PVC insulation V PVC sheath 2×6.0 mm² Two cores of 6.0 mm² copper conductor Construction : Two 6.0 mm² fine-stranded copper conductors, PVC insulation on each core...
4+1 Core 4*16mm² + 1*10mm² Copper Power Cable ZR-YJV XLPE Flame Retardant 0.6/1kV
4+1 Core 4*16mm² + 1*10mm² Copper Power Cable ZR-YJV XLPE Flame Retardant 0.6/1kV Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×16 mm² + 1×10 mm² Four cores of 16 mm² (3 phase + 1 neutral) + one ...
0.6/1kV XLPE Copper Cable ZR-YJV 4x25mm²+1x16mm² Flame Retardant for Power Supply
0.6/1kV XLPE Copper Cable ZR-YJV 4x25mm²+1x16mm² Flame Retardant for Power Supply Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×25 mm² + 1×16 mm² Four cores of 25 mm² (3 phase + 1 neutral) + one ...
Construction Site Power Cable ZR-YJV 4x35mm²+1x16mm² Flame Retardant Copper XLPE
Construction Site Power Cable ZR-YJV 4x35mm²+1x16mm² Flame Retardant Copper XLPE Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×35 mm² + 1×16 mm² Four cores of 35 mm² (3 phase + 1 neutral) + one ...
Copper Core 5 Core Shielded Cable 4x50mm2+1x25mm2 XLPE Flame Retardant 0.6/1kV
Copper Core 4+1 Cable ZR-YJV 4x50mm²+1x25mm² XLPE Flame Retardant 0.6/1kV Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×50 mm² + 1×25 mm² Four cores of 50 mm² (3 phase + 1 neutral) + one earth ...
Earth 5 Cores Cable 4x70mm2+1x35mm2 XLPE Copper Flame Retardant 600 1000V
5 Core + Earth Cable ZR-YJV 4x70mm²+1x35mm² XLPE Copper Flame Retardant 0.6/1kV Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×70 mm² + 1×35 mm² Four cores of 70 mm² (3 phase + 1 neutral) + one ...