RVV 2x0.75mm2 2 Core Flexible Cable Stranded Copper Conductor PVC Sheathed
Basic Properties
Trading Properties
Product Summary
Product Details
RVV2 Core Flexible Cable
,2x0.75mm2 2 Core Flexible Cable
,ISO sheathed flexible cable
Product Description
RVV-2*0.75mm² Flexible Control Cable 2 Core Stranded Copper Conductor PVC Insulated PVC Outer Sheathed
Cable Designation & Meaning
|
Code |
Meaning |
|---|---|
|
R |
Flexible conductor |
|
V |
PVC insulation |
|
V |
PVC sheath |
|
2×0.75 mm² |
Two cores of 0.75 mm² copper conductor |
Construction: Two 0.75 mm² fine-stranded copper conductors, PVC insulation on each core, PVC outer sheath over twisted cores with filler. No metallic screen/armour as standard (can be added on request as RVVP).


RVV 2×0.75 mm² — Flexible PVC Insulated PVC Sheathed Control Cord — Specification
1. Overview & Ratings. RVV 2×0.75 is a flexible two-core control cord rated 300/500 V, 70 °C working: two 0.75 mm² fine-strand soft copper cores (Class 5/6) with PVC insulation inside a flexible round PVC sheath. OD ≈ 5.5 mm, ≈ 65 kg/km (est.), ≈ 10 A per core free air at 30 °C (est.). Scope: instrument signal wiring, control-panel circuits and appliance leads — not a 0.6/1 kV XLPE power feeder.
2. Construction Stack (Inner → Outer, expanded).
| Layer / Feature | Build | Function |
|---|---|---|
| Conductors L & N | 2×0.75 soft Cu, Class 5/6, ≈24/0.20 strands | R ≤24.5 Ω/km; flexible |
| Fine-strand stranding | Many fine strands bunched & twisted | Repeated-bend flexibility |
| PVC insulation | Extruded, ≈0.6 mm, 70°C grade | Light 300/500 V dielectric |
| Two-core laying | Two cores laid parallel | Compact round cord |
| Flexible PVC sheath | ≈0.8 mm overall | Binds cores, abrasion jacket |
| Optional screen | Braid/foil (RVVP variant) | EMI signal immunity |
3. Electrical Characteristics. R ≤ 24.5 Ω/km @20 °C. Test 2.0 kV AC / 5 min; ≈ 10 A per core (est., air 30 °C); 300/500 V; 50/60 Hz; unscreened as standard, RVVP screened variant available.
Insulation & Sheath Data
|
Property |
Value |
|---|---|
|
Insulation material |
PVC (Type TI2) |
|
Outer sheath material |
PVC (Type ST5) |
|
Long-term service temp. |
70 °C (continuous) |
|
Max. conductor temp. (normal) |
70 °C |
|
Short-circuit temp. (≤5 s) |
160 °C |
|
Emergency overload temp. |
100 °C (≤1 h) |
|
Test voltage AC (5 min) |
2.0 kV |
|
Dielectric strength |
≥ 20 kV/mm |
|
Volume resistivity @20 °C |
≥ 1×10¹³ Ω·cm |
|
Shield |
None as standard (RVVP available) |
Electrical Parameters
|
Parameter |
Value |
Note |
|---|---|---|
|
Rated voltage U₀/U |
300 / 500 V |
GB/T 5023.5 / IEC 60227-5 |
|
Max. system voltage |
500 V AC / 700 V DC |
— |
|
Test voltage AC (5 min) |
2.0 kV |
Routine test |
|
DC resistance @20 °C |
≤ 26.0 Ω/km per core |
GB/T 3956 Class 5 Cu max (0.75 mm²) |
|
AC resistance @70 °C (est.) |
≈ 32.0 Ω/km per core |
— |
|
Current rating in air (30 °C) |
Single-phase AC: 13 A |
2×0.75, touching, in free air |
|
Current rating in tray (30 °C) |
Single-phase AC: 15 A |
2×0.75, spaced |
|
Current rating in conduit (30 °C) |
Single-phase AC: 10 A |
— |
|
Short-circuit current (1 s, Cu, 160 °C) |
≈ 82 A per core |
— |
|
Capacitance (core-to-core, approx.) |
≈ 0.09 µF/km |
PVC |
|
Inductive reactance (approx.) |
≈ 0.11 Ω/km |
at 50 Hz |
|
Frequency |
50/60 Hz AC |
— |
Reference values: RVV 2×0.75 at 13 A single-phase, 230 V → max load ≈ 3.0 kW (cos φ = 1.0). Suitable for signal wiring, low-current control circuits, sensors, and very light-duty portable equipment.
4. Thermal & Flame. 70 °C continuous; standard PVC — specify flame-retardant grade where wiring rules require; indoor control use preferred, not a fire-rated circuit.
Temperature Characteristics
|
Property |
Value |
|---|---|
|
Max. conductor operating temp. |
70 °C (continuous) |
|
Max. short-circuit temp. (≤5 s) |
160 °C |
|
Emergency overload temp. |
100 °C (≤1 h) |
|
Min. installation ambient temp. |
−15 °C |
|
Service ambient range |
−15 °C to +70 °C |
|
Flexing temp. range |
−5 °C to +70 °C |
Fire Performance (RVV — Standard, Non-Flame-Retardant)
|
Property |
Value / Requirement |
|---|---|
|
Flame retardant |
GB/T 18380.12 / IEC 60332-1-2 (single cable, self-extinguishing) |
|
Flame retardant class |
None as standard (use ZC-RVV for Class C) |
|
Halogen content |
Contains halogen (PVC) |
|
Smoke density |
Not low-smoke |
|
Corrosivity |
Corrosive (PVC) |
|
Toxicity |
Toxic fumes when burned |
|
EMI shielding |
None (use RVVP for shielded version) |
5. Installation Practice & Handling. Crimp cord-end ferrules or pins on the fine strands before screw terminals; bend ≥ 6×OD ≈ 33 mm; avoid sharp edges and kinking; verify continuity of both cores and insulation after dressing.
Mechanical & Installation Parameters
|
Parameter |
Value |
Remarks |
|---|---|---|
|
Minimum bending radius |
≥ 6 × OD → ≈ 43 mm at Ø7.2 mm |
flexible cable |
|
Max. pulling tension |
11.25 N per core (0.75 mm² × 15 N/mm²) |
Cu conductor limit |
|
Direct burial |
Not recommended (use buried conduit) |
— |
|
Surface mounting |
Cable tray, conduit, trunking, cable clips |
— |
|
Conduit ID |
≥ 16 mm |
— |
|
Fixing |
cable ties, clips |
— |
|
Impact resistance |
Low (light-duty) |
— |
|
Water resistance |
Limited (PVC sheath) |
— |
|
UV resistance |
Poor (PVC degrades outdoors, use UV-resistant or conduit) |
— |
|
Flex life |
Excellent (Class 5 fine-stranded) |
flexible / portable |
|
Termination note |
Screw terminals, compression lugs, or direct crimp (ferrule recommended) |
— |
6. Typical Service Applications. Instrument signal wiring, control-panel circuits, lighting and appliance leads, and security/building weak-current connections.

7. Testing & QA Regime (16 items). Routine: DC resistance, 2.0 kV withstand, insulation resistance, continuity, conductor construction, sheath/insulation thickness, dimensional check, core color coding, print legibility, mass, appearance, packing. Type: flame (if grade ordered), flexibility/bending, sheath tensile/elongation.
Cable Parameters
| RVV 2×0.75 mm² — Full Parameter Sheet | ||||
| Copper-core PVC-insulated PVC-sheathed flexible cord · 300/500 V · GB/T 5023.5 / IEC 60227-5 (60227 IEC 52) · finished Ø ≈ 6.1 mm · ≈ 55 kg/km — cross-referenced industry sample data | ||||
| Section | Parameter | Value | Unit | Remarks / Standard |
| 01 · Identification | ||||
| Cable type | RVV | — | Copper conductor, PVC insulation, PVC sheath, flexible round cord (60227 IEC 52) | |
| Rated voltage (U0/U) | 300/500 | V | AC 50 Hz; maximum system voltage Um = 500 V | |
| Number of cores | 2 | — | Two-core round flexible cord | |
| Nominal cross-sectional area | 0.75 × 2 | mm² | Per conductor | |
| Conductor material | Annealed copper (Cu) | — | Class 5 flexible stranded per GB/T 3956 / IEC 60228 | |
| Insulation material | PVC, PVC/C (TI1) compound | — | 70 °C rated | |
| Sheath material | PVC, PVC/ST5 compound | — | Black or custom colour | |
| Standard reference | GB/T 5023.5 / IEC 60227-5 | — | 60227 IEC 52 RVV flexible cords | |
| 02 · Conductor | ||||
| Stranding (per core) | 26 × 0.19 mm | — | Class 5 flexible lay-up | |
| Conductor diameter | ≈ 1.5 | mm | Strand-lay diameter (est.) | |
| DC resistance @ 20 °C | ≤ 26 | Ω/km | Maximum per GB/T 3956 Class 5 | |
| DC resistance @ 70 °C | ≈ 33 | Ω/km | Temperature-corrected (est.) | |
| Copper mass (both cores) | ≈ 13.4 | kg/km | 2 × 0.75 × 8.89 g/cm³ | |
| Conductor flexibility | Class 5 (flexible) | — | Suitable for repeated bending / appliance leads | |
| 03 · Insulation | ||||
| Insulation thickness (per core) | 0.5 | mm | GB/T 5023.5 specified for 0.75 mm² | |
| Core Ø over insulation | ≈ 2.5 | mm | 1.5 + 2 × 0.5 | |
| Insulation material | PVC, PVC/C (TI1) | — | Thermoplastic, 70 °C rated | |
| Insulation resistance @ 70 °C | ≥ 0.010 | MΩ·km | Finished cable, minimum | |
| PVC insulation tensile strength | ≥ 10 | MPa | Type test | |
| PVC insulation elongation at break | ≥ 100 | % | Type test | |
| Insulation colour | Black / red / blue / yellow-green | — | Standard; custom colour combinations available | |
| 04 · Assembly | ||||
| Core arrangement | Two cores laid parallel and cabled | — | Round 2-core lay-up | |
| Filler | None (interstices filled by extrusion) | — | Compact round shape | |
| Binder tape | Not required | — | Sheath extrudes over the pair | |
| Assembled core Ø | ≈ 5.0 | mm | Derived: 6.1 − 2 × 0.55 sheath | |
| Lay-up direction | Right-hand (S) | — | Standard convention | |
| 05 · Sheath | ||||
| Sheath material | PVC, PVC/ST5 compound | — | Black or custom colour | |
| Sheath thickness | 0.55 | mm | Per GB/T 5023.5 for ≈ 5.0 mm assembled Ø | |
| Overall finished diameter | ≈ 6.1 | mm | Cross-referenced industry 2-core sample | |
| Approximate cable mass | ≈ 55 | kg/km | Cross-referenced industry data | |
| PVC sheath tensile strength | ≥ 10 | MPa | Type test | |
| PVC sheath elongation at break | ≥ 125 | % | Type test | |
| Mass per 100 m | ≈ 5.5 | kg/100 m | For reel / carton loading estimation | |
| 06 · Electrical | ||||
| Rated voltage U0/U | 300/500 | V | AC 50 Hz | |
| Maximum system voltage Um | 500 | V | — | |
| DC resistance @ 20 °C | ≤ 26 | Ω/km | GB/T 3956 Class 5 | |
| AC impedance @ 50 Hz | ≈ 26 | Ω/km | R-dominant; negligible reactance | |
| Capacitance (typical) | ≈ 100 | nF/km | Per core (est.) | |
| Insulation resistance @ 70 °C | ≥ 0.010 | MΩ·km | Finished cable, minimum | |
| Routine test voltage | 2.0 kV AC / 5 min | — | Power-frequency withstand, no breakdown | |
| Air ampacity @ 25 °C | ≈ 6 | A | Two cores loaded, Cu (est.) | |
| Voltage drop @ 6 A | ≈ 0.16 | V/m | 2 × 26 × 6 / 1000 (est.) | |
| 07 · Thermal | ||||
| Max continuous conductor temp. | 70 | °C | PVC rated | |
| Max ambient temp. (service) | +70 | °C | Conductor-limited | |
| Min ambient temp. (service) | −15 | °C | PVC flexibility limit | |
| Min laying temperature | 0 | °C | Warm reels below 0 °C | |
| Thermal coefficient of resistance (Cu) | 0.00393 | 1/°C | At 20 °C reference | |
| 08 · Flame (flammability) | ||||
| Flame-retardant behaviour | Non-flame-spreading | — | Per GB/T 18380.12 (IEC 60332-1) | |
| Halogen content | Halogen-bearing (PVC) | — | Emits HCl under fire | |
| Smoke emission | Emits smoke under fire | — | PVC insulation and sheath | |
| Special LSZH version | Not standard | — | Specify LSZH variant for public areas | |
| 09 · Installation | ||||
| Min bending radius (flexible cord) | ≥ 6 × OD ≈ 37 | mm | OD = actual finished diameter | |
| Max pulling tension | ≤ 30 | N | ≈ 20 N/mm² of total copper area (est.) | |
| Laying methods | Fixed wiring inside appliances, ducting, trunking | — | Indoor dry locations | |
| Outdoor / burial note | Not for direct burial or outdoor UV exposure | — | Use UV-stabilised or armoured cable if required | |
| Termination | Solder, crimp ferrule or screw terminal | — | Strip 8–10 mm for flexible Class 5 conductors | |
| Flexing / flexible use | Suitable for occasional movement | — | Not for continuous repetitive flexing (use H05VV5-F if so) | |
| 10 · Packing | ||||
| Standard supply length | 100 | m/reel or carton | Custom lengths available | |
| Reel / packing type | Plastic reel or carton | — | Sealed until installation | |
| Surface marking | Type, voltage, supplier, year, metre marks | — | Per GB/T 6995 | |
| Storage conditions | Dry, covered, −15 to +40 °C | — | Away from sunlight, moisture, oils, sharp objects | |
| Transport | Reels secured against rolling | — | Do not drag cable over rough ground | |
Cable Test Parameters
| Test Parameters — RVV 2×0.75 mm² | ||||
| No. | Test Item | Test Condition / Method | Requirement | Type |
| 1 | Conductor DC resistance | GB/T 3048.4, 20 °C | ≤ 26 Ω/km per conductor | Routine |
| 2 | Power-frequency withstand | 2.0 kV AC, 5 min | No breakdown | Routine |
| 3 | Insulation resistance @ 70 °C | GB/T 3048.5, 70 °C | ≥ 0.010 MΩ·km | Routine |
| 4 | Conductor continuity | Visual + electrical | Both cores continuous | Routine |
| 5 | Dimensional check | Micrometer | Insulation ≥ 0.5 mm; sheath ≥ 0.55 mm; OD ≈ 6.1 mm | Routine |
| 6 | PVC insulation tensile & elongation | GB/T 2951.11 | Tensile ≥ 10 MPa; elongation ≥ 100 % | Type |
| 7 | PVC sheath tensile & elongation | GB/T 2951.11 | Tensile ≥ 10 MPa; elongation ≥ 125 % | Type |
| 8 | PVC heat deformation | 80 °C, 4 h, load | Deformation ≤ 50 % | Type |
| 9 | PVC shrinkage test | 150 °C, 1 h | Shrinkage ≤ 4 % | Type |
| 10 | Single-cable vertical flame | GB/T 18380.12 | Self-extinguishing; char ≤ 50 mm above burner | Type |
| 11 | Bending / flexing test | ≥ 6 × OD mandrel | No crack in insulation or sheath | Type |
| 12 | Cold bend test | −15 °C, 4 h | No cracking after mandrel bend | Type |
| 13 | Ozone / weathering (outdoor variant) | As required | Per customer specification | Optional |
| 14 | Voltage test after bending | 2.0 kV AC, 5 min | No breakdown after flexing | Type |
| 15 | Marking legibility | Visual + rubbing | Type/voltage/supplier/metre marks legible | Routine |
| 16 | Core identification | Visual + continuity | Correct colour-coded conductors identified | Routine |
Cable Cross Section Structure

| RVV 2×0.75 mm² — Cross-Section Construction Diagram (Schematic) | |||||
| Layered 2-core flexible build-up from fine copper strands to PVC jacket · nominal dimensions per GB/T 5023.5 / IEC 60227-5 · finished Ø ≈ 6.1 mm per cross-referenced industry sample | |||||
| No. | Layer | Material / Construction | Nominal Thickness (mm) | Diameter (mm) | Function / Remarks |
| 1 | Conductor (Cu) × 2 | Annealed copper, Class 5 flexible stranded — 26 wires of 0.19 mm per core (1+6+19 layout), nominal area 0.75 mm² each | — | ≈ 1.5 (Ø each conductor) | Flexible line conductors; DC resistance capped at 26 Ω/km at 20 °C |
| 2 | Insulation (PVC) × 2 | PVC compound, PVC/C (TI1) | 0.5 | ≈ 2.5 (Ø each insulated core) | Electrical isolation; 70 °C continuous rating; withstands 2.0 kV for 5 min |
| 3 | Core assembly | Two insulated cores laid parallel and cabled; interstices filled by sheath extrusion | — | ≈ 5.0 (Ø over assembled cores) | Round 2-core lay-up; derived from finished Ø 6.1 − 2×0.55 sheath |
| 4 | Outer sheath (PVC) | PVC compound, PVC/ST5, black or custom | 0.55 | ≈ 6.1 (Ø finished cable) | Mechanical protection and abrasion resistance; non-flame-spreading per GB/T 18380.12 |
| Key Dimensions & Properties (expanded) | |||||
| Finished cable diameter | ≈ 6.1 | mm | Cross-referenced industry 2-core sample | ||
| Approximate cable mass | ≈ 55 | kg/km | Cu build-up (cross-referenced industry data) | ||
| Nominal voltage rating | 300/500 | V | AC 50 Hz; maximum system voltage Um = 500 V | ||
| Conductor temperature limit | 70 | °C | Continuous service | ||
| Minimum bend radius (flexible) | ≥ 6 × OD ≈ 37 | mm | OD = actual finished cable diameter | ||
| Flame behaviour | Non-flame-spreading | — | Per GB/T 18380.12 | ||
| Conductor DC resistance | ≤ 26 | Ω/km | At 20 °C, per GB/T 3956 Class 5 | ||
| Insulation resistance @ 70 °C | ≥ 0.010 | MΩ·km | Finished cable, minimum | ||
| Routine test voltage | 2.0 kV AC / 5 min | — | Power-frequency withstand | ||
| AC impedance @ 50 Hz | ≈ 26 | Ω/km | R-dominant (est.) | ||
| Capacitance (typical) | ≈ 100 | nF/km | Per core (est.) | ||
| Air ampacity @ 25 °C | ≈ 6 | A | Two cores loaded, Cu (est.) | ||
| Voltage drop @ 6 A | ≈ 0.16 | V/m | Loop drop (est.) | ||
| Maximum pulling tension | ≤ 30 | N | ≈ 20 N/mm² of total copper area (est.) | ||
| Mass per 100 m | ≈ 5.5 | kg/100 m | For reel / carton loading | ||
| Schematic — not to exact scale. Finished Ø ≈ 6.1 mm and weight ≈ 55 kg/km from cross-referenced industry samples; conductor/insulation diameters calculated from GB/T 3956 and GB/T 5023.5; ampacity 6 A is an engineering estimate for 2-core flexible cords. Values marked (est.) require confirmation against the factory test certificate. | |||||
Construction Description
| Construction Description — RVV 2×0.75 mm² | |||
| Layer-by-layer build-up narrative, conductor through outer jacket · per GB/T 5023.5 & IEC 60227-5 · CU / PVC / PVC · 300/500 V class · finished Ø ≈ 6.1 mm (cross-referenced industry sample) | |||
| 1. Product Identity & Ratings | |||
| RVV 2×0.75 is a compact two-core flexible PVC cord designed for light-duty power and signal interconnection: two 0.75 mm² annealed copper conductors, each insulated in PVC and collectively sheathed in a second PVC overjacket, rated for 300/500 V AC at 50 Hz and a 70 °C conductor temperature. It is manufactured and type-tested to GB/T 5023.5 (60227 IEC 52) / IEC 60227-5, with Class 5 flexible conductors per GB/T 3956. The finished diameter is about 6.1 mm (cross-referenced industry sample) and the nominal mass is roughly 55 kg per kilometre (≈ 5.5 kg per 100 m), supplied on 100 m reels or cartons. | |||
| With both cores energised, the cord carries about 6 A in free air at 25 °C (engineering estimate), suited to appliance leads, lamp connections, instrument wiring and low-current control circuits rather than heavy distribution feeders. | |||
| 2. Flexible Copper Conductors | |||
| Each 0.75 mm² conductor is stranded from twenty-six 0.19 mm annealed wires in the 1+6+19 arrangement — the Class 5 flexible standard at this cross-section — giving a strand-lay diameter of about 1.5 mm and a DC resistance ceiling of 26 Ω/km at 20 °C (about 33 Ω/km at the 70 °C operating point). The many fine wires give the cord its flexibility and bending endurance, which is why it is preferred for appliance connections and equipment leads rather than fixed building wiring. Copper mass is about 6.7 kg/km per core, 13.4 kg/km in total. | |||
| 3. PVC Insulation | |||
| PVC is extruded at 0.50 mm onto each 0.75 mm² conductor, producing approximately 2.5 mm per insulated core. The insulation is rated for 70 °C continuous duty, passes the routine 2.0 kV AC five-minute voltage proof, and maintains insulation resistance above 0.010 MΩ·km at 70 °C. Insulation colours are standardised (commonly brown/blue for 230 V mains, or red/black for DC and signal circuits) and may be specified to order. | |||
| 4. Cabling & PVC Outer Sheath | |||
| After insulation, the two cores are laid parallel and cabled; the interstices are filled by the extruded sheath itself, forming a compact round bundle of about 5.0 mm diameter. A 0.55 mm layer of PVC (ST5 compound) is then extruded over the pair to the ≈ 6.1 mm finish. The jacket provides abrasion resistance and mechanical protection, and the whole cord meets the single-cable vertical flame test GB/T 18380.12. Because both insulation and sheath are halogenated PVC, the cord emits smoke and HCl in a fire; for public or confined spaces, specify a low-smoke zero-halogen variant. | |||
| 5. Site Handling & Operational Notes | |||
| • Observe the 6 × OD minimum bending radius (≈ 37 mm). • Strip 8–10 mm for termination and always use a ferrule on the flexible Class 5 strands to prevent wire fraying. • Service ambient spans −15 to +70 °C; warm reels indoors before pulling below 0 °C. • The 6 A reference requires derating for ambient temperature and bundling. • Maximum pulling tension ≤ 30 N; do not use the cord as a pulling rope. • Not for direct burial, outdoor UV exposure or continuous repetitive flexing — for those duties choose an armoured cable, UV-stabilised jacket or a continuous-flex (trunking) cable respectively. • Use reels with flanges suited to the ≈ 6.1 mm OD. |
8. Factory Advantages.
- Fine-strand flexibility — Class 5/6 soft wire dresses easily and resists work-hardening on bends.
- Clean extruded PVC — even insulation and jacket layers every run.
- Tight diameter control — ≈5.5 mm fits control glands, connectors and light chains.
- Length-on-demand — cut to the exact panel-to-device or appliance lead.
- Color-pair options — pre-colored cores match the wiring schedule.
- Continuous print line — type, size and voltage readable along the cord.
- Lightweight reel pack — low mass on a coil or small drum with sealed ends.
- RVVP screened variant — braid/foil shield for EMI-sensitive signal.
- Certified QA pack — routine resistance, voltage and continuity records per batch.
9. Packaging, Storage & Logistics. Cut to measured lead length on a coil or small drum with sealed ends; store dry indoor, shaded, avoid UV.

10. Procurement Specification. State "RVV 2×0.75", length, core colors and whether a flame-retardant or screened (RVVP) grade is required; request the routine test record. Ferrules recommended on fine strands. Est. values confirmed against the factory certificate.
11. Cable Industry FAQ.
- Q1: How does RVV 2×0.75 differ from a ZC-YJV 4×70+1×35 power cable? Different product classes: a light flexible two-core 300/500 V control cord vs a rigid four-plus-one 0.6/1 kV XLPE power feeder — 0.75 mm² soft PVC/PVC vs 70/35 mm² compacted copper, ≈10 A vs ≈175 A, OD 5.5 vs 31 mm; control/signal use rather than main power distribution.
- Q2: Why ferrules on the ends? Fine Class 5/6 strands can stray at screw terminals; a cord-end ferrule gives a solid, reliable termination.
- Q3: Can it carry 220 V appliances? For light appliance and internal leads, yes within the ≈10 A rating; do not size it for heavy mains feed.
- Q4: DC resistance? ≤24.5 Ω/km at 20°C for the flexible 0.75 mm² conductor.
- Q5: Need shielding? Add RVVP braid/foil near analog signal EMI; standard RVV is unscreened.
- Q6: Current per core? ≈10 A (est.) free air 30°C; derate in bundles and enclosed trunking.
- Q7: Bending? ≈33 mm (6×OD); the flexible cord bends tightly but avoid kinking.
- Q8: What temperature? 70 °C PVC class — not 90 °C XLPE.
- Q9: Indoor or outdoor? Indoor panel/appliance preferred; specify UV jacket for exposed runs.
- Q10: Packing? Coil or small drum with sealed ends.
- Q11: What proof ships? Routine resistance, voltage and continuity records; est. values confirmed against certificate.