High Capacity 5 Core Flex ZR-YJV 4x300mm2+1x150mm2 XLPE Copper Flame Retardant

High Capacity 5 Core Flex ZR-YJV 4x300mm2+1x150mm2 XLPE Copper Flame Retardant

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
ZR-YJV 4x300mm²+1x150mm²

Trading Properties

moq
1 Meter
payment method
L/C,T/T
supply capacity
10000 meters per month

Product Summary

High Capacity 4+1 Core Cable ZR-YJV 4x300mm²+1x150mm² XLPE Copper Flame Retardant Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — ...

Product Details

Highlight:

High Capacity 5 core flex

,

5 core flex 4x300mm2

,

Flame Retardant pvc outer jacket

Phase/Neutral conductor (×4):
Bare Annealed Copper, Class 2 Stranded, 61×∅2.52 Mm, Conductor Ø ≈ 22.7–24.1 Mm Depending On Compaction
PE conductor (×1):
Bare Annealed Copper, Class 2 Stranded, 37×∅2.27 Mm, Conductor Ø ≈ 15.9–16.9 Mm Depending On Compaction
Phase/Neutral conductor nominal area:
300 Mm²
PE conductor nominal area:
150 Mm²
Number of cores:
5 (4+1)
Phase/Neutral conductor construction:
Class 2, 61×∅2.52 Mm
PE conductor construction:
Class 2, 37×∅2.27 Mm
Phase/Neutral conductor diameter (approx.):
22.7–24.1 Mm
PE conductor diameter (approx.):
15.9–16.9 Mm
Insulation (×5):
XLPE, Colours: Brown/black/grey (L1/L2/L3), Blue (N), Yellow/green Striped (PE)
Phase/Neutral insulation thickness:
1.8 Mm (300 Mm² Class)
PE insulation thickness:
1.4 Mm (150 Mm² Class)
Diameter over phase/neutral insulated core:
26.3–27.7 Mm
Diameter over PE insulated core:
18.7–19.7 Mm
Filler / binder:
FR PP Filler + FR Tape
Outer sheath:
Flame-retardant PVC (ZR Grade)
Sheath thickness:
2.4 Mm (GB/T 12706 Multi-core ≥240 Mm² Range)
Overall cable diameter:
58.0 – 68.0 Mm
Design outer diameter:
≈ 61.5 Mm
Approx. weight:
6600 – 7900 Kg/km
Design weight:
≈ 7200 Kg/km
Cable shape:
Round

Product Description

High Capacity 4+1 Core Cable ZR-YJV 4x300mm²+1x150mm² XLPE Copper Flame Retardant


Cable Designation & Meaning


Code

Meaning

ZR

Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC).

YJ

XLPE (cross-linked polyethylene) insulation

V

PVC outer sheath — flame-retardant grade, contains halogen (Cl)

0.6/1 kV

Rated voltage U₀/U = 600/1000 V; Uₘ = 1.2 kV

4×300+1×150 mm²

Four equal phase/neutral cores of 300 mm² copper + one reduced protective earth (PE) core of 150 mm² copper


High Capacity 5 Core Flex ZR-YJV 4x300mm2+1x150mm2 XLPE Copper Flame Retardant


ZC-YJV 4×300+1×150 mm² — Heavy LV Flame-Retardant 4+1 Main-Inlet Cable — Specification

1. Overview & Ratings. ZC-YJV 4×300+1×150 is a heavy five-core (4+1) LV main-inlet cable rated 0.6/1 kV (Um 1.2), 90 °C working, ZC class C PVC sheath: four 300 mm² compacted copper cores (L1/L2/L3 plus a PE/spare core) and a reduced 150 mm² neutral, dry-cured XLPE, unarmored. OD ≈ 62 mm, ≈ 13500 kg/km (est.), ≈ 500 A per core free air at 30 °C (est.). Scope: main inlet lines, switchgear main bus, transformer LV secondary ties, large motor banks and vertical risers — not 950°C fire duty.


2. Construction Stack (Inner → Outer, expanded).


Layer / Feature Build Function
Large cores L1/L2/L3/PE 4×300 compacted Cu, Class 2, ≈61 strands each R ≤0.0601 Ω/km
Neutral N 1×150 compacted Cu, Class 2, ≈37 strands R ≤0.124 Ω/km
Strand compaction Concentric layers rolled compact per core Compact heavy bundle, clean lugs
XLPE large-core insulation Dry-cured PE, ≈2.8 mm Uniform 90°C dielectric
XLPE neutral insulation Dry-cured PE, ≈2.5 mm Matched to neutral voltage class
4+1 core laying Four large cores arranged around the neutral Heavy round five-core bundle
PVC ZC sheath Class C, ≈2.8 mm overall Self-extinguishes, prints clear


3. Electrical Characteristics. Large-core R ≤ 0.0601 Ω/km, neutral R ≤ 0.124 Ω/km @20 °C. Test 3.5 kV AC / 5 min; ≈ 500 A per core (est., air 30 °C); short-circuit ≈ 33 kA / 1 s (est.); 50/60 Hz; unscreened; low-loss XLPE; high stable insulation resistance.

Insulation & Sheath Data

Property

Value

Insulation material

XLPE (cross-linked polyethylene)

Outer sheath material

PVC (ST₂)

Long-term service temp.

90 °C (continuous)

Max. conductor temp. (normal)

90 °C

Short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Test voltage AC (5 min)

3.5 kV

Dielectric strength

≥ 20 kV/mm

Volume resistivity @20 °C

≥ 1×10¹⁴ Ω·cm

Shield

None as standard (can be added)

Electrical Parameters

Parameter

Value

Note

Rated voltage U₀/U

0.6 / 1 kV

GB/T 12706.1 / IEC 60502-1

Max. system voltage

1.2 kV AC

—

Test voltage AC (5 min)

3.5 kV

Routine test

DC resistance @20 °C (phase/neutral)

≤ 0.0601 Ω/km per core

GB/T 3956 Class 2 Cu max (300 mm²)

DC resistance @20 °C (earth)

≤ 0.124 Ω/km per core

GB/T 3956 Class 2 Cu max (150 mm²)

AC resistance @90 °C (est., phase/neutral)

≈ 0.077 Ω/km per core

—

AC resistance @90 °C (est., earth)

≈ 0.159 Ω/km per core

—

Current rating in air (30 °C)

3-phase: 525 A​

4×300+1×150, touching, in free air

Current rating in tray (30 °C)

3-phase: 570 A​

4×300+1×150, spaced 2×OD

Current rating buried in ground (20 °C, thermal resistivity 1.2 K·m/W)

3-phase: 545 A​

direct buried

Current rating in conduit (30 °C)

3-phase: 470 A​

—

Short-circuit current (1 s, Cu, 250 °C, phase/neutral)

≈ 33.0 kA (33,000 A) per core

—

Short-circuit current (1 s, Cu, 250 °C, earth)

≈ 16.5 kA (16,500 A) per core

—

Capacitance (core-to-sheath, approx.)

≈ 0.32 µF/km

XLPE

Inductive reactance (approx.)

≈ 0.08 Ω/km

at 50 Hz

Frequency

50/60 Hz AC

—


Reference values: 4×300+1×150 at 525 A three-phase, 400 V → max load ≈ 315 kW​ (cos φ = 0.8). Suitable for ultra-heavy three-phase distribution with full-size neutral and separate earth (TN-S), heavy industrial plants, and main incoming feeders.


4. Thermal & Flame. 90 °C continuous, 250 °C short-time; ZC class C self-extinguishing — flame retardancy, not 950°C integrity; withstands heavy load cycling; indoor switchgear preferred, UV jacket optional for exposed risers.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

90 °C (continuous)

Max. short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Min. installation ambient temp.

0 °C (below 0 °C requires preheating)

Service ambient range

−20 °C to +90 °C

Flexing temp. range

0 °C to +90 °C

Fire Performance (ZC-YJV — Flame Retardant C)

Property

Value / Requirement

Flame retardant

GB/T 18380.12 / IEC 60332-1-2​ (single cable, self-extinguishing)

Flame retardant class

Class C​ (ZC) per GB/T 19666

Halogen content

Contains halogen (PVC sheath)

Smoke density

Not low-smoke (PVC)

Corrosivity

Corrosive (PVC)

Toxicity

Toxic fumes when burned (PVC)

EMI shielding

None (no metallic screen/armour)


5. Installation Practice & Handling. Hydraulic crimp four 300 mm² lugs and a 150 mm² neutral lug, heavy glands to ≈62 mm OD, torque per table; bend ≥ 15×OD ≈ 930 mm on large sheaves; apply bus-duct/tray derating; keep the heavy bundle round; verify continuity of all cores, phase sequence, neutral and insulation at the switchgear before energizing.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 15 × OD → ≈ 795 mm at Ø53.0 mm

five-core unarmoured

Max. pulling tension (phase/neutral)

4,500 N per core (300 mm² × 15 N/mm²)

Cu conductor limit

Max. pulling tension (earth)

2,250 N per core (150 mm² × 15 N/mm²)

Cu conductor limit

Direct burial

Suitable (with sand bedding)

—

Surface mounting

Heavy-duty cable tray, ladder, cleats

—

Conduit ID

≥ 110 mm

—

Fixing

heavy-duty cleats, cable ties

—

Impact resistance

Moderate

—

Water resistance

Good (PVC sheath)

—

UV resistance

Fair (PVC degrades outdoors, use UV-resistant PVC or conduit)

—

Flex life

Good (Class 2 stranded)

fixed installation

Termination note

Standard compression lugs or mechanical connectors

—


6. Typical Service Applications. LV main inlets, switchgear main buses, transformer LV secondary ties, large motor banks, and vertical plant risers.


High Capacity 5 Core Flex ZR-YJV 4x300mm2+1x150mm2 XLPE Copper Flame Retardant


7. Testing & QA Regime (16 items). Routine: large-core and neutral DC resistance, 3.5 kV withstand, insulation resistance, continuity of all cores, large-core/neutral insulation thickness, sheath thickness, dimensional check, strand construction, eccentricity, print legibility, mass, packing inspection. Type: ZC flame test, short-circuit rating, sheath mechanical.


Cable Parameters


ZR-YJV 4×300+1×150 mm² — Full Parameter Sheet 
Flame-retardant 4+1-core CU/XLPE/PVC power cable · 0.6/1 kV · GB/T 12706.1 / IEC 60502-1 · finished Ø ≈ 74 mm · ≈ 14800 kg/km (Cu) — cross-referenced industry sample data
Section Parameter Value Unit Remarks / Standard
01 · Identification

Cable type ZR-YJV — Flame-retardant, Cu conductor, XLPE insulation, PVC sheath

Rated voltage (U0/U) 0.6/1 kV AC 50 Hz; maximum system voltage Um = 1.2 kV

Rated cross-sectional areas 4 × 300 (phase) + 1 × 150 (neutral) mm² 4+1 five-core configuration, reduced neutral/PE

Conductor material Annealed copper (Cu) — Class 2 stranded per GB/T 3956 / IEC 60228

Insulation material Cross-linked polyethylene (XLPE) — 90 °C continuous rating

Sheath material Flame-retardant PVC, ST2 compound — Black; halogen-bearing

Flame-retardant class ZC (ZR) — Per GB/T 19666; ZA/ZB available on request

Standard reference GB/T 12706.1 / IEC 60502-1 — 0.6/1 kV extruded-insulation power cables
02 · Conductor

Phase stranding (×4) 61 × 2.52 mm (1+6+12+18+24) — Stranded lay-up; 300 mm² each

Neutral stranding (×1) 37 × 2.25 mm (1+6+12+18) — Stranded lay-up; 150 mm²

Phase conductor diameter ≈ 22.4 mm Strand-lay diameter (est.)

Neutral conductor diameter ≈ 15.8 mm Strand-lay diameter (est.)

Phase DC resistance @ 20 °C 0.0601 Ω/km Maximum per GB/T 3956 Class 2

Neutral DC resistance @ 20 °C 0.124 Ω/km Maximum per GB/T 3956 Class 2

Phase DC resistance @ 90 °C ≈ 0.076 Ω/km Temperature-corrected (est.)

Copper mass — phase (per core) ≈ 2667 kg/km 300 mm² × 8.89 g/cm³

Copper mass — neutral ≈ 1334 kg/km 150 mm² × 8.89 g/cm³

Total copper mass ≈ 12002 kg/km 4 × 2667 + 1334
03 · Insulation

Phase insulation thickness 1.8 mm GB/T 12706.1 specified for 300 mm²

Neutral insulation thickness 1.8 mm GB/T 12706.1 specified for 150 mm²

Phase core Ø over insulation ≈ 26.0 mm 22.4 + 2 × 1.8

Neutral core Ø over insulation ≈ 19.4 mm 15.8 + 2 × 1.8

Insulation material XLPE — Cross-linked polyethylene

XLPE volume resistivity ≥ 1×10¹² Ω·cm At 20 °C

XLPE tensile strength ≥ 12.5 MPa Type test

XLPE elongation at break ≥ 200 % Type test

XLPE hot-set (200 °C, 15 min, 0.2 MPa) ≤ 175 / ≤ 15 % / % Load elongation / permanent set

Total XLPE mass ≈ 520 kg/km 4 phase + 1 neutral (est.)
04 · Assembly

Core arrangement Neutral at centre + 4 phase cores around — 4+1 five-core lay-up

Filler material Polypropylene (PP) rope — Fills interstices between cores

Binder tape Polyester non-woven tape — Holds assembled cores

Assembled core Ø ≈ 70.4 mm Derived: 74 − 2 × 1.8 sheath

Lay-up direction Right-hand (S) — Standard multi-core convention
05 · Sheath

Sheath material Flame-retardant PVC, ST2 — Black, halogen-bearing

Sheath thickness 1.8 mm Per GB/T 12706.1 for ≈ 70.4 mm assembled Ø

Overall finished diameter ≈ 74.0 mm Cross-referenced industry 4+1 sample

Approximate cable mass (Cu) ≈ 14800 kg/km Cross-referenced industry data

Approximate cable mass (Al) ≈ 6600 kg/km YJLV equivalent (est.)

PVC tensile strength ≥ 10 MPa Type test

PVC elongation at break ≥ 125 % Type test

PVC thermal stability ≥ 200 min @ 200 °C (HCl evolution)

Mass per 100 m (Cu) ≈ 1480 kg/100 m For drum loading estimation
06 · Electrical

Rated voltage U0/U 0.6/1 kV AC 50 Hz

Maximum system voltage Um 1.2 kV —

Phase DC resistance @ 20 °C ≤ 0.0601 Ω/km GB/T 3956 Class 2

Neutral DC resistance @ 20 °C ≤ 0.124 Ω/km GB/T 3956 Class 2

AC impedance @ 50 Hz ≈ 0.07 Ω/km √(R² + X²); R-dominant (est.)

Capacitance (typical) ≤ 0.55 μF/km Per phase core (est.)

Inductance (typical) ≈ 0.26 mH/km Multi-core cable (est.)

Insulation resistance @ 90 °C ≥ 36.7 MΩ·km Finished cable, minimum

Routine test voltage 3.5 kV AC / 5 min — Power-frequency withstand, no breakdown

Site commissioning test DC 2.4 kV / 15 min — 4U0 per Q/GDW 13244.1-2018

Air ampacity @ 25 °C ≈ 500 A 4 phase cores loaded, Cu (est.)

Buried ampacity @ 25 °C ≈ 420 A 4 phase cores loaded, Cu (est.)

Short-circuit current (1 s) ≈ 34.5 kA Phase: I = k·A/√t, k=115 for Cu/XLPE
07 · Thermal

Max continuous conductor temp. 90 °C XLPE rated

Max short-circuit temp. (≤ 5 s) 250 °C XLPE limit

Min ambient temp. (service) −20 °C —

Max ambient temp. (service) +45 °C —

Min laying temperature 0 °C Warm drums below 0 °C

Max burial soil temp. 25 °C Reference for ampacity

Thermal coefficient of resistance (Cu) 0.00393 1/°C At 20 °C reference
08 · Fire (ZR)

Flame-retardant class ZC — GB/T 19666 default for ZR marking

Single-cable flame test GB/T 18380.12 — Equivalent IEC 60332-1-2

Bunched flame test GB/T 18380.35 category C — Char height ≤ 2.5 m

Halogen content Halogen-bearing (PVC) — Specify WDZ-YJY for LSZH

Smoke emission Emits smoke under fire — PVC jacket; LSZH alternative available
09 · Installation

Min bending radius (multi-core) ≥ 15 × OD ≈ 1110 mm OD = actual finished diameter

Max pulling tension ≤ 48000 N 40 N/mm² of main phase core area (est.)

Recommended drum flange Ø ≥ 2000 mm For this section

Laying methods Conduit, tray, trunking, indoor ducting — Indoor or sheltered outdoor

Direct burial note Use armoured ZR-YJV22 for burial — Unarmoured YJV needs conduit/protection

Termination Crimp lugs + heat-shrink or screw terminals — Size for 22.4 mm phase / 15.8 mm neutral core
10 · Packing

Standard supply length 100 m/coil or drum Custom lengths available

Drum type Wooden drum (≥ Ø 2000 mm flange) — Sealed until installation

Surface marking Type, voltage, supplier, year, metre marks — Per GB/T 6995

Storage conditions Dry, covered, −20 to +45 °C — Away from sunlight, moisture, oils, sharp objects

Transport Coils/drums secured against rolling — Do not drag cable over rough ground


Cable Test Parameters


Test Parameters — ZR-YJV 4×300+1×150 mm²
No. Test Item Test Condition / Method Requirement Type
1 Conductor DC resistance GB/T 3048.4, 20 °C Phase ≤ 0.0601 Ω/km; Neutral ≤ 0.124 Ω/km Routine
2 Power-frequency withstand 3.5 kV AC, 5 min No breakdown Routine
3 Insulation resistance GB/T 3048.5, 90 °C ≥ 36.7 MΩ·km Routine
4 Conductor continuity Visual + electrical All 5 cores continuous Routine
5 Dimensional check Micrometer Phase ins. ≥ 1.8 mm; neutral ≥ 1.8 mm; sheath ≥ 1.8 mm; OD ≈ 74 mm Routine
6 XLPE hot-set test 200 ± 3 °C, 15 min, 0.2 MPa Load elongation ≤ 175 %; permanent set ≤ 15 % Type
7 XLPE tensile & elongation GB/T 2951.11 Tensile ≥ 12.5 MPa; elongation ≥ 200 % Type
8 PVC sheath tensile & elongation GB/T 2951.11 Tensile ≥ 10 MPa; elongation ≥ 125 % Type
9 PVC thermal stability 200 °C, HCl evolution ≥ 200 min Type
10 Single-cable vertical flame GB/T 18380.12 Self-extinguishing; char ≤ 50 mm above burner Type
11 Bunched cable flame (cat. C) GB/T 18380.35 Char height ≤ 2.5 m Type
12 Bending test ≥ 15 × OD mandrel No crack in insulation or sheath Type
13 Heat deformation (PVC) 80 °C, 4 h, load Deformation ≤ 50 % Type
14 XLPE shrinkage test 130 °C, 1 h Shrinkage ≤ 4 % Type
15 Site DC withstand 4U0 = 2.4 kV DC, 15 min No breakdown (Q/GDW 13244.1-2018) Site
16 Core identification Visual + continuity Correct L1/L2/L3/N/PE identification Site


Cable Cross Section Structure


High Capacity 5 Core Flex ZR-YJV 4x300mm2+1x150mm2 XLPE Copper Flame Retardant

ZR-YJV 4×300+1×150 mm² — Cross-Section Construction Diagram (Schematic)
Layered 4+1 conductor build-up from copper strand to PVC jacket · nominal dimensions per GB/T 12706.1 / IEC 60502-1 · finished Ø ≈ 74 mm per cross-referenced industry sample
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Phase conductor (Cu) × 4 Annealed copper, Class 2 stranded — 61 wires of 2.52 mm per core (1+6+12+18+24 layout), nominal area 300 mm² each — ≈ 22.4 (Ø each phase core) Line-current carrying phase conductors; DC resistance capped at 0.0601 Ω/km at 20 °C
2 Neutral conductor (Cu) × 1 Annealed copper, Class 2 stranded — 37 wires of 2.25 mm (1+6+12+18 layout), nominal area 150 mm² — ≈ 15.8 (Ø neutral core) Return / PE path; DC resistance capped at 0.124 Ω/km at 20 °C
3 Phase insulation (XLPE) × 4 Cross-linked polyethylene dielectric 1.8 ≈ 26.0 (Ø each phase core, incl. insulation) Electrical isolation; 90 °C continuous rating; withstands 3.5 kV for 5 min
4 Neutral insulation (XLPE) × 1 Cross-linked polyethylene dielectric 1.8 ≈ 19.4 (Ø neutral core, incl. insulation) Electrical isolation for the neutral/PE conductor
5 Core assembly Neutral core at centre + four phase cores cabled around + PP filler + polyester binder tape — ≈ 70.4 (Ø over assembled cores) 4+1 configuration; derived from finished Ø 74 − 2×1.8 sheath
6 Outer jacket (PVC) Flame-retardant PVC, ST2 compound, black 1.8 ≈ 74.0 (Ø finished cable) Mechanical and moisture protection; ZC flame retardance per GB/T 19666
Key Dimensions & Properties (expanded)
Finished cable diameter ≈ 74.0 mm Cross-referenced industry 4+1 sample

Approximate cable mass ≈ 14800 kg/km Cu build-up (cross-referenced industry data)

Approximate mass, aluminium build ≈ 6600 kg/km YJLV equivalent (est.)

Nominal voltage rating 0.6/1 kV AC 50 Hz; maximum system voltage Um = 1.2 kV

Conductor temperature limits 90 / 250 °C Continuous service / short-circuit (≤ 5 s)

Minimum bend radius (multi-core) ≥ 15 × OD ≈ 1110 mm OD = actual finished cable diameter

Flame-retardant classification ZC (ZR) — Per GB/T 19666

Short-circuit current, phase (1 s) ≈ 34.5 kA I = k·A/√t, k=115 for Cu/XLPE

Short-circuit current, neutral (1 s) ≈ 17.3 kA 150 mm² neutral, same k factor

AC impedance @ 50 Hz ≈ 0.07 Ω/km √(R² + X²); R-dominant (est.)

Capacitance (typical) ≤ 0.55 μF/km Per phase core (est.)

Inductance (typical) ≈ 0.26 mH/km Multi-core cable (est.)

Air ampacity @ 25 °C ≈ 500 A 4 phase cores loaded, Cu (est.)

Buried ampacity @ 25 °C ≈ 420 A 4 phase cores loaded, Cu (est.)

Maximum pulling tension ≤ 48000 N 40 N/mm² of main phase core area (est.)

Schematic — not to exact scale. Finished Ø ≈ 74 mm and weight ≈ 14800 kg/km from cross-referenced industry samples; conductor/insulation diameters calculated from GB/T 3956 and GB/T 12706.1; ampacity 500/420 A is an engineering estimate for 4+1 cables. Values marked (est.) require confirmation against the factory test certificate.


Construction Description


Construction Description — ZR-YJV 4×300+1×150 mm² 
Layer-by-layer build-up narrative, conductor through outer jacket · per GB/T 12706.1 & IEC 60502-1 · CU / XLPE / PVC · 0.6/1 kV class · finished Ø ≈ 74 mm (cross-referenced industry sample)
1. Product Identity & Ratings
ZR-YJV 4×300+1×150 represents the largest 4+1-core flame-retardant cable in this standard low-voltage series, engineered for the heaviest distribution loads: four 300 mm² annealed copper phase conductors surround a central 150 mm² copper neutral/PE core, each insulated in XLPE and collectively enclosed in a single ST2 PVC jacket for 0.6/1 kV service. It is manufactured and type-tested to GB/T 12706.1 / IEC 60502-1, stranded to GB/T 3956, and marked ZR for class ZC flame retardance under GB/T 19666. The finished diameter is about 74 mm (cross-referenced industry sample) and the nominal mass is roughly 14800 kg per kilometre in copper (6600 kg/km for the aluminium YJLV equivalent); standard supply is 100 m coils or wooden drums with ≥ Ø 2000 mm flanges (≈ 1480 kg per 100 m).
With all four phase cores energised, the cable supports about 500 A in free air at 25 °C and 420 A directly buried at 25 °C (engineering estimate) — the highest current rating in the 4+1 range. The 4+1 arrangement places the reduced 150 mm² core at the centre and lays the four 300 mm² phase cores around it.
2. Copper Stranded Conductors
Each 300 mm² phase core is stranded from sixty-one 2.52 mm annealed wires in the 1+6+12+18+24 arrangement — the Class 2 standard at this cross-section — giving a strand-lay diameter of about 22.4 mm and a DC resistance ceiling of 0.0601 Ω/km at 20 °C (about 0.076 Ω/km at the 90 °C operating point). The 150 mm² neutral/PE core uses thirty-seven 2.25 mm wires (1+6+12+18) to about 15.8 mm strand-lay Ø, with resistance capped at 0.124 Ω/km. Copper mass alone is about 2667 kg/km per phase core and 1334 kg/km for the neutral; the sixty-one-wire phase lay-up is the most rigid in the 4+1 range and should be handled with the largest bending radii and powered pulling equipment.
3. XLPE Dielectric Insulation
XLPE is extruded at 1.8 mm onto each 300 mm² phase core and 1.8 mm onto the 150 mm² neutral core — producing approximately 26.0 mm per phase core and 19.4 mm for the neutral core over the insulation. The dielectric is rated for 90 °C continuous duty and 250 °C for five seconds, maintains volume resistivity above 1×10¹² Ω·cm, passes the routine 3.5 kV AC five-minute voltage proof, and offers tensile strength ≥ 12.5 MPa with elongation ≥ 200 %. Total XLPE mass is about 520 kg/km.
4. Cabling & PVC Outer Jacket
After insulation, the 150 mm² neutral core is placed at the centre and the four 300 mm² phase cores are cabled around it in a square arrangement with polypropylene filler and a polyester binder tape, forming a bundle of about 70.4 mm diameter (derived from the finished size). A 1.8 mm layer of flame-retarded ST2 PVC is then extruded over the assembly to the ≈ 74 mm finish. The jacket provides ZC behaviour through GB/T 18380.12 and GB/T 18380.35, offers tensile strength ≥ 10 MPa and elongation ≥ 125 %; because PVC is halogenated, low-smoke zero-halogen projects should specify WDZ-YJY, and direct-burial projects without added protection should specify steel-tape armoured ZR-YJV22.
5. Site Handling & Operational Notes
• Observe the 15 × OD minimum bending radius (≈ 1110 mm).  • Perform the DC 4U0 = 2.4 kV / 15 min commissioning test before first energisation.  • Service ambient spans −20 to +45 °C; warm drums below 0 °C before pulling.  • Derate the 500 A (air) / 420 A (buried) references for ambient temperature, grouping and soil conditions.  • Maximum pulling tension ≤ 48000 N; use suitable pulling grips and a winch for longer runs.  • Select lugs and terminals matched to the 22.4 mm phase core, 15.8 mm neutral core and ≈ 74 mm jacket.  • Short-circuit rating ≈ 34.5 kA for 1 s on the phase (≈ 17.3 kA basis on the neutral) — verify against protective device settings.  • Use drums with ≥ Ø 2000 mm flanges (≈ 1480 kg per 100 m).


8. Factory Advantages.

  • Heavy 4+1 main-inlet sizing — four large cores carry full duty while the reduced 150 neutral avoids excess copper on balanced loads.
  • Stable XLPE cure on large cores — even cross-linking keeps the 90°C dielectric consistent under sustained high-current load.
  • Dosed ZC compound — self-extinguishing jacket protects switchgear rooms and main cable basements.
  • Length-on-demand — cut to exact inlet meter with sealed ends.
  • Dual-section resistance log — 300 cores and 150 neutral R recorded to lot for traceability.
  • Continuous print line — type, size, ZC, voltage and length readable along heavy runs.
  • Core-color option — L1/L2/L3/PE/N colors reduce wiring errors at switchboards.
  • Extra-heavy drum pack — structurally rated drum with sealed ends for ocean shipment.
  • Certified QA pack — routine + type test record supports witness testing and commissioning.


High Capacity 5 Core Flex ZR-YJV 4x300mm2+1x150mm2 XLPE Copper Flame Retardant


9. Packaging, Storage & Logistics. Cut to measured main-inlet length on an extra-heavy wooden drum with sealed ends; continuous marking; store dry indoor on strong drum supports, shaded, avoid direct UV.


High Capacity 5 Core Flex ZR-YJV 4x300mm2+1x150mm2 XLPE Copper Flame Retardant


10. Procurement Specification. State "ZC-YJV 4×300+1×150", length, class C, core colors; define the fourth large core (PE vs spare phase); note the reduced neutral suits balanced loads (enlarge for high harmonics) and not fire-rated; request the dual-section resistance log and 16-item QA record. Est. values confirmed against the factory certificate.


11. Cable Industry FAQ.

  • Q1: How does 4×300+1×150 differ from 4×70? A heavy five-core main-inlet build rather than a small four-core branch: four 300 mm² cores vs four 70 mm², plus a 150 neutral; OD 62 vs 26 mm, mass 13500 vs 3300 kg/km, core current 500 vs 175 A, large-core R 0.0601 vs 0.268 Ω/km; built for switchgear inlets and bus ties rather than mid-heavy branches.
  • Q2: What are the four 300 cores? Three phases (L1/L2/L3) plus a fourth large core used as protective/PE or a spare phase; the 150 mm² wire is the neutral.
  • Q3: Is ZC fire-resistant? No. Class C self-extinguishes; it does not hold live at 950°C/180min.
  • Q4: DC resistance values? 300 cores ≤0.0601; 150 neutral ≤0.124 Ω/km at 20°C.
  • Q5: Screen or armor? Unscreened standard; add braid near VFD EMI; steel-tape/wire armor for buried heavy-duty ducts.
  • Q6: Current per core? ≈500 A (est.) free air 30°C; derate in bus ducts and crowded trays.
  • Q7: Bending? ≈930 mm (15×OD); use large sheaves and pulling equipment on this five-core section.
  • Q8: Connectors? Four 300 mm² lugs and a 150 mm² neutral lug; heavy gland to ≈62 mm OD.
  • Q9: Indoor or outdoor? Indoor switchgear preferred; specify UV-stabilized jacket for exposed risers.
  • Q10: Packing? Extra-heavy wooden drum with moisture-sealed ends.
  • Q11: What proof ships? Dual-section resistance log + 16-test record; est. values confirmed against certificate.