High Capacity 5 Core Flex ZR-YJV 4x300mm2+1x150mm2 XLPE Copper Flame Retardant
Product Summary
Product Details
High Capacity 5 core flex
,5 core flex 4x300mm2
,Flame Retardant pvc outer jacket
Product Description
High Capacity 4+1 Core Cable ZR-YJV 4x300mm²+1x150mm² XLPE Copper Flame Retardant
Cable Designation & Meaning
|
Code |
Meaning |
|---|---|
|
ZR |
Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). |
|
YJ |
XLPE (cross-linked polyethylene) insulation |
|
V |
PVC outer sheath — flame-retardant grade, contains halogen (Cl) |
|
0.6/1 kV |
Rated voltage U₀/U = 600/1000 V; Uₘ = 1.2 kV |
|
4×300+1×150 mm² |
Four equal phase/neutral cores of 300 mm² copper + one reduced protective earth (PE) core of 150 mm² copper |

ZC-YJV 4×300+1×150 mm² — Heavy LV Flame-Retardant 4+1 Main-Inlet Cable — Specification
1. Overview & Ratings. ZC-YJV 4×300+1×150 is a heavy five-core (4+1) LV main-inlet cable rated 0.6/1 kV (Um 1.2), 90 °C working, ZC class C PVC sheath: four 300 mm² compacted copper cores (L1/L2/L3 plus a PE/spare core) and a reduced 150 mm² neutral, dry-cured XLPE, unarmored. OD ≈ 62 mm, ≈ 13500 kg/km (est.), ≈ 500 A per core free air at 30 °C (est.). Scope: main inlet lines, switchgear main bus, transformer LV secondary ties, large motor banks and vertical risers — not 950°C fire duty.
2. Construction Stack (Inner → Outer, expanded).
| Layer / Feature | Build | Function |
|---|---|---|
| Large cores L1/L2/L3/PE | 4×300 compacted Cu, Class 2, ≈61 strands each | R ≤0.0601 Ω/km |
| Neutral N | 1×150 compacted Cu, Class 2, ≈37 strands | R ≤0.124 Ω/km |
| Strand compaction | Concentric layers rolled compact per core | Compact heavy bundle, clean lugs |
| XLPE large-core insulation | Dry-cured PE, ≈2.8 mm | Uniform 90°C dielectric |
| XLPE neutral insulation | Dry-cured PE, ≈2.5 mm | Matched to neutral voltage class |
| 4+1 core laying | Four large cores arranged around the neutral | Heavy round five-core bundle |
| PVC ZC sheath | Class C, ≈2.8 mm overall | Self-extinguishes, prints clear |
3. Electrical Characteristics. Large-core R ≤ 0.0601 Ω/km, neutral R ≤ 0.124 Ω/km @20 °C. Test 3.5 kV AC / 5 min; ≈ 500 A per core (est., air 30 °C); short-circuit ≈ 33 kA / 1 s (est.); 50/60 Hz; unscreened; low-loss XLPE; high stable insulation resistance.
Insulation & Sheath Data
|
Property |
Value |
|---|---|
|
Insulation material |
XLPE (cross-linked polyethylene) |
|
Outer sheath material |
PVC (ST₂) |
|
Long-term service temp. |
90 °C (continuous) |
|
Max. conductor temp. (normal) |
90 °C |
|
Short-circuit temp. (≤5 s) |
250 °C |
|
Emergency overload temp. |
130 °C (≤1 h) |
|
Test voltage AC (5 min) |
3.5 kV |
|
Dielectric strength |
≥ 20 kV/mm |
|
Volume resistivity @20 °C |
≥ 1×10¹⁴ Ω·cm |
|
Shield |
None as standard (can be added) |
Electrical Parameters
|
Parameter |
Value |
Note |
|---|---|---|
|
Rated voltage U₀/U |
0.6 / 1 kV |
GB/T 12706.1 / IEC 60502-1 |
|
Max. system voltage |
1.2 kV AC |
— |
|
Test voltage AC (5 min) |
3.5 kV |
Routine test |
|
DC resistance @20 °C (phase/neutral) |
≤ 0.0601 Ω/km per core |
GB/T 3956 Class 2 Cu max (300 mm²) |
|
DC resistance @20 °C (earth) |
≤ 0.124 Ω/km per core |
GB/T 3956 Class 2 Cu max (150 mm²) |
|
AC resistance @90 °C (est., phase/neutral) |
≈ 0.077 Ω/km per core |
— |
|
AC resistance @90 °C (est., earth) |
≈ 0.159 Ω/km per core |
— |
|
Current rating in air (30 °C) |
3-phase: 525 A |
4×300+1×150, touching, in free air |
|
Current rating in tray (30 °C) |
3-phase: 570 A |
4×300+1×150, spaced 2×OD |
|
Current rating buried in ground (20 °C, thermal resistivity 1.2 K·m/W) |
3-phase: 545 A |
direct buried |
|
Current rating in conduit (30 °C) |
3-phase: 470 A |
— |
|
Short-circuit current (1 s, Cu, 250 °C, phase/neutral) |
≈ 33.0 kA (33,000 A) per core |
— |
|
Short-circuit current (1 s, Cu, 250 °C, earth) |
≈ 16.5 kA (16,500 A) per core |
— |
|
Capacitance (core-to-sheath, approx.) |
≈ 0.32 µF/km |
XLPE |
|
Inductive reactance (approx.) |
≈ 0.08 Ω/km |
at 50 Hz |
|
Frequency |
50/60 Hz AC |
— |
Reference values: 4×300+1×150 at 525 A three-phase, 400 V → max load ≈ 315 kW (cos φ = 0.8). Suitable for ultra-heavy three-phase distribution with full-size neutral and separate earth (TN-S), heavy industrial plants, and main incoming feeders.
4. Thermal & Flame. 90 °C continuous, 250 °C short-time; ZC class C self-extinguishing — flame retardancy, not 950°C integrity; withstands heavy load cycling; indoor switchgear preferred, UV jacket optional for exposed risers.
Temperature Characteristics
|
Property |
Value |
|---|---|
|
Max. conductor operating temp. |
90 °C (continuous) |
|
Max. short-circuit temp. (≤5 s) |
250 °C |
|
Emergency overload temp. |
130 °C (≤1 h) |
|
Min. installation ambient temp. |
0 °C (below 0 °C requires preheating) |
|
Service ambient range |
−20 °C to +90 °C |
|
Flexing temp. range |
0 °C to +90 °C |
Fire Performance (ZC-YJV — Flame Retardant C)
|
Property |
Value / Requirement |
|---|---|
|
Flame retardant |
GB/T 18380.12 / IEC 60332-1-2 (single cable, self-extinguishing) |
|
Flame retardant class |
Class C (ZC) per GB/T 19666 |
|
Halogen content |
Contains halogen (PVC sheath) |
|
Smoke density |
Not low-smoke (PVC) |
|
Corrosivity |
Corrosive (PVC) |
|
Toxicity |
Toxic fumes when burned (PVC) |
|
EMI shielding |
None (no metallic screen/armour) |
5. Installation Practice & Handling. Hydraulic crimp four 300 mm² lugs and a 150 mm² neutral lug, heavy glands to ≈62 mm OD, torque per table; bend ≥ 15×OD ≈ 930 mm on large sheaves; apply bus-duct/tray derating; keep the heavy bundle round; verify continuity of all cores, phase sequence, neutral and insulation at the switchgear before energizing.
Mechanical & Installation Parameters
|
Parameter |
Value |
Remarks |
|---|---|---|
|
Minimum bending radius |
≥ 15 × OD → ≈ 795 mm at Ø53.0 mm |
five-core unarmoured |
|
Max. pulling tension (phase/neutral) |
4,500 N per core (300 mm² × 15 N/mm²) |
Cu conductor limit |
|
Max. pulling tension (earth) |
2,250 N per core (150 mm² × 15 N/mm²) |
Cu conductor limit |
|
Direct burial |
Suitable (with sand bedding) |
— |
|
Surface mounting |
Heavy-duty cable tray, ladder, cleats |
— |
|
Conduit ID |
≥ 110 mm |
— |
|
Fixing |
heavy-duty cleats, cable ties |
— |
|
Impact resistance |
Moderate |
— |
|
Water resistance |
Good (PVC sheath) |
— |
|
UV resistance |
Fair (PVC degrades outdoors, use UV-resistant PVC or conduit) |
— |
|
Flex life |
Good (Class 2 stranded) |
fixed installation |
|
Termination note |
Standard compression lugs or mechanical connectors |
— |
6. Typical Service Applications. LV main inlets, switchgear main buses, transformer LV secondary ties, large motor banks, and vertical plant risers.

7. Testing & QA Regime (16 items). Routine: large-core and neutral DC resistance, 3.5 kV withstand, insulation resistance, continuity of all cores, large-core/neutral insulation thickness, sheath thickness, dimensional check, strand construction, eccentricity, print legibility, mass, packing inspection. Type: ZC flame test, short-circuit rating, sheath mechanical.
Cable Parameters
| ZR-YJV 4×300+1×150 mm² — Full Parameter Sheet | ||||
| Flame-retardant 4+1-core CU/XLPE/PVC power cable · 0.6/1 kV · GB/T 12706.1 / IEC 60502-1 · finished Ø ≈ 74 mm · ≈ 14800 kg/km (Cu) — cross-referenced industry sample data | ||||
| Section | Parameter | Value | Unit | Remarks / Standard |
| 01 · Identification | ||||
| Cable type | ZR-YJV | — | Flame-retardant, Cu conductor, XLPE insulation, PVC sheath | |
| Rated voltage (U0/U) | 0.6/1 | kV | AC 50 Hz; maximum system voltage Um = 1.2 kV | |
| Rated cross-sectional areas | 4 × 300 (phase) + 1 × 150 (neutral) | mm² | 4+1 five-core configuration, reduced neutral/PE | |
| Conductor material | Annealed copper (Cu) | — | Class 2 stranded per GB/T 3956 / IEC 60228 | |
| Insulation material | Cross-linked polyethylene (XLPE) | — | 90 °C continuous rating | |
| Sheath material | Flame-retardant PVC, ST2 compound | — | Black; halogen-bearing | |
| Flame-retardant class | ZC (ZR) | — | Per GB/T 19666; ZA/ZB available on request | |
| Standard reference | GB/T 12706.1 / IEC 60502-1 | — | 0.6/1 kV extruded-insulation power cables | |
| 02 · Conductor | ||||
| Phase stranding (×4) | 61 × 2.52 mm (1+6+12+18+24) | — | Stranded lay-up; 300 mm² each | |
| Neutral stranding (×1) | 37 × 2.25 mm (1+6+12+18) | — | Stranded lay-up; 150 mm² | |
| Phase conductor diameter | ≈ 22.4 | mm | Strand-lay diameter (est.) | |
| Neutral conductor diameter | ≈ 15.8 | mm | Strand-lay diameter (est.) | |
| Phase DC resistance @ 20 °C | 0.0601 | Ω/km | Maximum per GB/T 3956 Class 2 | |
| Neutral DC resistance @ 20 °C | 0.124 | Ω/km | Maximum per GB/T 3956 Class 2 | |
| Phase DC resistance @ 90 °C | ≈ 0.076 | Ω/km | Temperature-corrected (est.) | |
| Copper mass — phase (per core) | ≈ 2667 | kg/km | 300 mm² × 8.89 g/cm³ | |
| Copper mass — neutral | ≈ 1334 | kg/km | 150 mm² × 8.89 g/cm³ | |
| Total copper mass | ≈ 12002 | kg/km | 4 × 2667 + 1334 | |
| 03 · Insulation | ||||
| Phase insulation thickness | 1.8 | mm | GB/T 12706.1 specified for 300 mm² | |
| Neutral insulation thickness | 1.8 | mm | GB/T 12706.1 specified for 150 mm² | |
| Phase core Ø over insulation | ≈ 26.0 | mm | 22.4 + 2 × 1.8 | |
| Neutral core Ø over insulation | ≈ 19.4 | mm | 15.8 + 2 × 1.8 | |
| Insulation material | XLPE | — | Cross-linked polyethylene | |
| XLPE volume resistivity | ≥ 1×10¹² | Ω·cm | At 20 °C | |
| XLPE tensile strength | ≥ 12.5 | MPa | Type test | |
| XLPE elongation at break | ≥ 200 | % | Type test | |
| XLPE hot-set (200 °C, 15 min, 0.2 MPa) | ≤ 175 / ≤ 15 | % / % | Load elongation / permanent set | |
| Total XLPE mass | ≈ 520 | kg/km | 4 phase + 1 neutral (est.) | |
| 04 · Assembly | ||||
| Core arrangement | Neutral at centre + 4 phase cores around | — | 4+1 five-core lay-up | |
| Filler material | Polypropylene (PP) rope | — | Fills interstices between cores | |
| Binder tape | Polyester non-woven tape | — | Holds assembled cores | |
| Assembled core Ø | ≈ 70.4 | mm | Derived: 74 − 2 × 1.8 sheath | |
| Lay-up direction | Right-hand (S) | — | Standard multi-core convention | |
| 05 · Sheath | ||||
| Sheath material | Flame-retardant PVC, ST2 | — | Black, halogen-bearing | |
| Sheath thickness | 1.8 | mm | Per GB/T 12706.1 for ≈ 70.4 mm assembled Ø | |
| Overall finished diameter | ≈ 74.0 | mm | Cross-referenced industry 4+1 sample | |
| Approximate cable mass (Cu) | ≈ 14800 | kg/km | Cross-referenced industry data | |
| Approximate cable mass (Al) | ≈ 6600 | kg/km | YJLV equivalent (est.) | |
| PVC tensile strength | ≥ 10 | MPa | Type test | |
| PVC elongation at break | ≥ 125 | % | Type test | |
| PVC thermal stability | ≥ 200 | min | @ 200 °C (HCl evolution) | |
| Mass per 100 m (Cu) | ≈ 1480 | kg/100 m | For drum loading estimation | |
| 06 · Electrical | ||||
| Rated voltage U0/U | 0.6/1 | kV | AC 50 Hz | |
| Maximum system voltage Um | 1.2 | kV | — | |
| Phase DC resistance @ 20 °C | ≤ 0.0601 | Ω/km | GB/T 3956 Class 2 | |
| Neutral DC resistance @ 20 °C | ≤ 0.124 | Ω/km | GB/T 3956 Class 2 | |
| AC impedance @ 50 Hz | ≈ 0.07 | Ω/km | √(R² + X²); R-dominant (est.) | |
| Capacitance (typical) | ≤ 0.55 | μF/km | Per phase core (est.) | |
| Inductance (typical) | ≈ 0.26 | mH/km | Multi-core cable (est.) | |
| Insulation resistance @ 90 °C | ≥ 36.7 | MΩ·km | Finished cable, minimum | |
| Routine test voltage | 3.5 kV AC / 5 min | — | Power-frequency withstand, no breakdown | |
| Site commissioning test | DC 2.4 kV / 15 min | — | 4U0 per Q/GDW 13244.1-2018 | |
| Air ampacity @ 25 °C | ≈ 500 | A | 4 phase cores loaded, Cu (est.) | |
| Buried ampacity @ 25 °C | ≈ 420 | A | 4 phase cores loaded, Cu (est.) | |
| Short-circuit current (1 s) | ≈ 34.5 | kA | Phase: I = k·A/√t, k=115 for Cu/XLPE | |
| 07 · Thermal | ||||
| Max continuous conductor temp. | 90 | °C | XLPE rated | |
| Max short-circuit temp. (≤ 5 s) | 250 | °C | XLPE limit | |
| Min ambient temp. (service) | −20 | °C | — | |
| Max ambient temp. (service) | +45 | °C | — | |
| Min laying temperature | 0 | °C | Warm drums below 0 °C | |
| Max burial soil temp. | 25 | °C | Reference for ampacity | |
| Thermal coefficient of resistance (Cu) | 0.00393 | 1/°C | At 20 °C reference | |
| 08 · Fire (ZR) | ||||
| Flame-retardant class | ZC | — | GB/T 19666 default for ZR marking | |
| Single-cable flame test | GB/T 18380.12 | — | Equivalent IEC 60332-1-2 | |
| Bunched flame test | GB/T 18380.35 category C | — | Char height ≤ 2.5 m | |
| Halogen content | Halogen-bearing (PVC) | — | Specify WDZ-YJY for LSZH | |
| Smoke emission | Emits smoke under fire | — | PVC jacket; LSZH alternative available | |
| 09 · Installation | ||||
| Min bending radius (multi-core) | ≥ 15 × OD ≈ 1110 | mm | OD = actual finished diameter | |
| Max pulling tension | ≤ 48000 | N | 40 N/mm² of main phase core area (est.) | |
| Recommended drum flange Ø | ≥ 2000 | mm | For this section | |
| Laying methods | Conduit, tray, trunking, indoor ducting | — | Indoor or sheltered outdoor | |
| Direct burial note | Use armoured ZR-YJV22 for burial | — | Unarmoured YJV needs conduit/protection | |
| Termination | Crimp lugs + heat-shrink or screw terminals | — | Size for 22.4 mm phase / 15.8 mm neutral core | |
| 10 · Packing | ||||
| Standard supply length | 100 | m/coil or drum | Custom lengths available | |
| Drum type | Wooden drum (≥ Ø 2000 mm flange) | — | Sealed until installation | |
| Surface marking | Type, voltage, supplier, year, metre marks | — | Per GB/T 6995 | |
| Storage conditions | Dry, covered, −20 to +45 °C | — | Away from sunlight, moisture, oils, sharp objects | |
| Transport | Coils/drums secured against rolling | — | Do not drag cable over rough ground | |
Cable Test Parameters
| Test Parameters — ZR-YJV 4×300+1×150 mm² | ||||
| No. | Test Item | Test Condition / Method | Requirement | Type |
| 1 | Conductor DC resistance | GB/T 3048.4, 20 °C | Phase ≤ 0.0601 Ω/km; Neutral ≤ 0.124 Ω/km | Routine |
| 2 | Power-frequency withstand | 3.5 kV AC, 5 min | No breakdown | Routine |
| 3 | Insulation resistance | GB/T 3048.5, 90 °C | ≥ 36.7 MΩ·km | Routine |
| 4 | Conductor continuity | Visual + electrical | All 5 cores continuous | Routine |
| 5 | Dimensional check | Micrometer | Phase ins. ≥ 1.8 mm; neutral ≥ 1.8 mm; sheath ≥ 1.8 mm; OD ≈ 74 mm | Routine |
| 6 | XLPE hot-set test | 200 ± 3 °C, 15 min, 0.2 MPa | Load elongation ≤ 175 %; permanent set ≤ 15 % | Type |
| 7 | XLPE tensile & elongation | GB/T 2951.11 | Tensile ≥ 12.5 MPa; elongation ≥ 200 % | Type |
| 8 | PVC sheath tensile & elongation | GB/T 2951.11 | Tensile ≥ 10 MPa; elongation ≥ 125 % | Type |
| 9 | PVC thermal stability | 200 °C, HCl evolution | ≥ 200 min | Type |
| 10 | Single-cable vertical flame | GB/T 18380.12 | Self-extinguishing; char ≤ 50 mm above burner | Type |
| 11 | Bunched cable flame (cat. C) | GB/T 18380.35 | Char height ≤ 2.5 m | Type |
| 12 | Bending test | ≥ 15 × OD mandrel | No crack in insulation or sheath | Type |
| 13 | Heat deformation (PVC) | 80 °C, 4 h, load | Deformation ≤ 50 % | Type |
| 14 | XLPE shrinkage test | 130 °C, 1 h | Shrinkage ≤ 4 % | Type |
| 15 | Site DC withstand | 4U0 = 2.4 kV DC, 15 min | No breakdown (Q/GDW 13244.1-2018) | Site |
| 16 | Core identification | Visual + continuity | Correct L1/L2/L3/N/PE identification | Site |
Cable Cross Section Structure

| ZR-YJV 4×300+1×150 mm² — Cross-Section Construction Diagram (Schematic) | |||||
| Layered 4+1 conductor build-up from copper strand to PVC jacket · nominal dimensions per GB/T 12706.1 / IEC 60502-1 · finished Ø ≈ 74 mm per cross-referenced industry sample | |||||
| No. | Layer | Material / Construction | Nominal Thickness (mm) | Diameter (mm) | Function / Remarks |
| 1 | Phase conductor (Cu) × 4 | Annealed copper, Class 2 stranded — 61 wires of 2.52 mm per core (1+6+12+18+24 layout), nominal area 300 mm² each | — | ≈ 22.4 (Ø each phase core) | Line-current carrying phase conductors; DC resistance capped at 0.0601 Ω/km at 20 °C |
| 2 | Neutral conductor (Cu) × 1 | Annealed copper, Class 2 stranded — 37 wires of 2.25 mm (1+6+12+18 layout), nominal area 150 mm² | — | ≈ 15.8 (Ø neutral core) | Return / PE path; DC resistance capped at 0.124 Ω/km at 20 °C |
| 3 | Phase insulation (XLPE) × 4 | Cross-linked polyethylene dielectric | 1.8 | ≈ 26.0 (Ø each phase core, incl. insulation) | Electrical isolation; 90 °C continuous rating; withstands 3.5 kV for 5 min |
| 4 | Neutral insulation (XLPE) × 1 | Cross-linked polyethylene dielectric | 1.8 | ≈ 19.4 (Ø neutral core, incl. insulation) | Electrical isolation for the neutral/PE conductor |
| 5 | Core assembly | Neutral core at centre + four phase cores cabled around + PP filler + polyester binder tape | — | ≈ 70.4 (Ø over assembled cores) | 4+1 configuration; derived from finished Ø 74 − 2×1.8 sheath |
| 6 | Outer jacket (PVC) | Flame-retardant PVC, ST2 compound, black | 1.8 | ≈ 74.0 (Ø finished cable) | Mechanical and moisture protection; ZC flame retardance per GB/T 19666 |
| Key Dimensions & Properties (expanded) | |||||
| Finished cable diameter | ≈ 74.0 | mm | Cross-referenced industry 4+1 sample | ||
| Approximate cable mass | ≈ 14800 | kg/km | Cu build-up (cross-referenced industry data) | ||
| Approximate mass, aluminium build | ≈ 6600 | kg/km | YJLV equivalent (est.) | ||
| Nominal voltage rating | 0.6/1 | kV | AC 50 Hz; maximum system voltage Um = 1.2 kV | ||
| Conductor temperature limits | 90 / 250 | °C | Continuous service / short-circuit (≤ 5 s) | ||
| Minimum bend radius (multi-core) | ≥ 15 × OD ≈ 1110 | mm | OD = actual finished cable diameter | ||
| Flame-retardant classification | ZC (ZR) | — | Per GB/T 19666 | ||
| Short-circuit current, phase (1 s) | ≈ 34.5 | kA | I = k·A/√t, k=115 for Cu/XLPE | ||
| Short-circuit current, neutral (1 s) | ≈ 17.3 | kA | 150 mm² neutral, same k factor | ||
| AC impedance @ 50 Hz | ≈ 0.07 | Ω/km | √(R² + X²); R-dominant (est.) | ||
| Capacitance (typical) | ≤ 0.55 | μF/km | Per phase core (est.) | ||
| Inductance (typical) | ≈ 0.26 | mH/km | Multi-core cable (est.) | ||
| Air ampacity @ 25 °C | ≈ 500 | A | 4 phase cores loaded, Cu (est.) | ||
| Buried ampacity @ 25 °C | ≈ 420 | A | 4 phase cores loaded, Cu (est.) | ||
| Maximum pulling tension | ≤ 48000 | N | 40 N/mm² of main phase core area (est.) | ||
| Schematic — not to exact scale. Finished Ø ≈ 74 mm and weight ≈ 14800 kg/km from cross-referenced industry samples; conductor/insulation diameters calculated from GB/T 3956 and GB/T 12706.1; ampacity 500/420 A is an engineering estimate for 4+1 cables. Values marked (est.) require confirmation against the factory test certificate. | |||||
Construction Description
| Construction Description — ZR-YJV 4×300+1×150 mm² | |||
| Layer-by-layer build-up narrative, conductor through outer jacket · per GB/T 12706.1 & IEC 60502-1 · CU / XLPE / PVC · 0.6/1 kV class · finished Ø ≈ 74 mm (cross-referenced industry sample) | |||
| 1. Product Identity & Ratings | |||
| ZR-YJV 4×300+1×150 represents the largest 4+1-core flame-retardant cable in this standard low-voltage series, engineered for the heaviest distribution loads: four 300 mm² annealed copper phase conductors surround a central 150 mm² copper neutral/PE core, each insulated in XLPE and collectively enclosed in a single ST2 PVC jacket for 0.6/1 kV service. It is manufactured and type-tested to GB/T 12706.1 / IEC 60502-1, stranded to GB/T 3956, and marked ZR for class ZC flame retardance under GB/T 19666. The finished diameter is about 74 mm (cross-referenced industry sample) and the nominal mass is roughly 14800 kg per kilometre in copper (6600 kg/km for the aluminium YJLV equivalent); standard supply is 100 m coils or wooden drums with ≥ Ø 2000 mm flanges (≈ 1480 kg per 100 m). | |||
| With all four phase cores energised, the cable supports about 500 A in free air at 25 °C and 420 A directly buried at 25 °C (engineering estimate) — the highest current rating in the 4+1 range. The 4+1 arrangement places the reduced 150 mm² core at the centre and lays the four 300 mm² phase cores around it. | |||
| 2. Copper Stranded Conductors | |||
| Each 300 mm² phase core is stranded from sixty-one 2.52 mm annealed wires in the 1+6+12+18+24 arrangement — the Class 2 standard at this cross-section — giving a strand-lay diameter of about 22.4 mm and a DC resistance ceiling of 0.0601 Ω/km at 20 °C (about 0.076 Ω/km at the 90 °C operating point). The 150 mm² neutral/PE core uses thirty-seven 2.25 mm wires (1+6+12+18) to about 15.8 mm strand-lay Ø, with resistance capped at 0.124 Ω/km. Copper mass alone is about 2667 kg/km per phase core and 1334 kg/km for the neutral; the sixty-one-wire phase lay-up is the most rigid in the 4+1 range and should be handled with the largest bending radii and powered pulling equipment. | |||
| 3. XLPE Dielectric Insulation | |||
| XLPE is extruded at 1.8 mm onto each 300 mm² phase core and 1.8 mm onto the 150 mm² neutral core — producing approximately 26.0 mm per phase core and 19.4 mm for the neutral core over the insulation. The dielectric is rated for 90 °C continuous duty and 250 °C for five seconds, maintains volume resistivity above 1×10¹² Ω·cm, passes the routine 3.5 kV AC five-minute voltage proof, and offers tensile strength ≥ 12.5 MPa with elongation ≥ 200 %. Total XLPE mass is about 520 kg/km. | |||
| 4. Cabling & PVC Outer Jacket | |||
| After insulation, the 150 mm² neutral core is placed at the centre and the four 300 mm² phase cores are cabled around it in a square arrangement with polypropylene filler and a polyester binder tape, forming a bundle of about 70.4 mm diameter (derived from the finished size). A 1.8 mm layer of flame-retarded ST2 PVC is then extruded over the assembly to the ≈ 74 mm finish. The jacket provides ZC behaviour through GB/T 18380.12 and GB/T 18380.35, offers tensile strength ≥ 10 MPa and elongation ≥ 125 %; because PVC is halogenated, low-smoke zero-halogen projects should specify WDZ-YJY, and direct-burial projects without added protection should specify steel-tape armoured ZR-YJV22. | |||
| 5. Site Handling & Operational Notes | |||
| • Observe the 15 × OD minimum bending radius (≈ 1110 mm). • Perform the DC 4U0 = 2.4 kV / 15 min commissioning test before first energisation. • Service ambient spans −20 to +45 °C; warm drums below 0 °C before pulling. • Derate the 500 A (air) / 420 A (buried) references for ambient temperature, grouping and soil conditions. • Maximum pulling tension ≤ 48000 N; use suitable pulling grips and a winch for longer runs. • Select lugs and terminals matched to the 22.4 mm phase core, 15.8 mm neutral core and ≈ 74 mm jacket. • Short-circuit rating ≈ 34.5 kA for 1 s on the phase (≈ 17.3 kA basis on the neutral) — verify against protective device settings. • Use drums with ≥ Ø 2000 mm flanges (≈ 1480 kg per 100 m). |
8. Factory Advantages.
- Heavy 4+1 main-inlet sizing — four large cores carry full duty while the reduced 150 neutral avoids excess copper on balanced loads.
- Stable XLPE cure on large cores — even cross-linking keeps the 90°C dielectric consistent under sustained high-current load.
- Dosed ZC compound — self-extinguishing jacket protects switchgear rooms and main cable basements.
- Length-on-demand — cut to exact inlet meter with sealed ends.
- Dual-section resistance log — 300 cores and 150 neutral R recorded to lot for traceability.
- Continuous print line — type, size, ZC, voltage and length readable along heavy runs.
- Core-color option — L1/L2/L3/PE/N colors reduce wiring errors at switchboards.
- Extra-heavy drum pack — structurally rated drum with sealed ends for ocean shipment.
- Certified QA pack — routine + type test record supports witness testing and commissioning.

9. Packaging, Storage & Logistics. Cut to measured main-inlet length on an extra-heavy wooden drum with sealed ends; continuous marking; store dry indoor on strong drum supports, shaded, avoid direct UV.

10. Procurement Specification. State "ZC-YJV 4×300+1×150", length, class C, core colors; define the fourth large core (PE vs spare phase); note the reduced neutral suits balanced loads (enlarge for high harmonics) and not fire-rated; request the dual-section resistance log and 16-item QA record. Est. values confirmed against the factory certificate.
11. Cable Industry FAQ.
- Q1: How does 4×300+1×150 differ from 4×70? A heavy five-core main-inlet build rather than a small four-core branch: four 300 mm² cores vs four 70 mm², plus a 150 neutral; OD 62 vs 26 mm, mass 13500 vs 3300 kg/km, core current 500 vs 175 A, large-core R 0.0601 vs 0.268 Ω/km; built for switchgear inlets and bus ties rather than mid-heavy branches.
- Q2: What are the four 300 cores? Three phases (L1/L2/L3) plus a fourth large core used as protective/PE or a spare phase; the 150 mm² wire is the neutral.
- Q3: Is ZC fire-resistant? No. Class C self-extinguishes; it does not hold live at 950°C/180min.
- Q4: DC resistance values? 300 cores ≤0.0601; 150 neutral ≤0.124 Ω/km at 20°C.
- Q5: Screen or armor? Unscreened standard; add braid near VFD EMI; steel-tape/wire armor for buried heavy-duty ducts.
- Q6: Current per core? ≈500 A (est.) free air 30°C; derate in bus ducts and crowded trays.
- Q7: Bending? ≈930 mm (15×OD); use large sheaves and pulling equipment on this five-core section.
- Q8: Connectors? Four 300 mm² lugs and a 150 mm² neutral lug; heavy gland to ≈62 mm OD.
- Q9: Indoor or outdoor? Indoor switchgear preferred; specify UV-stabilized jacket for exposed risers.
- Q10: Packing? Extra-heavy wooden drum with moisture-sealed ends.
- Q11: What proof ships? Dual-section resistance log + 16-test record; est. values confirmed against certificate.