ZR-YJV 4×70mm² 0.6/1kV Flame Retardant Copper Cable, XLPE Insulation for Building Power Distribution
Product Summary
Product Details
zr-yjv 4 cores cable
,zr-yjv 25 sq mm 4 core cable
,1kv 4 cores cable
Product Description
ZR-YJV 4×70mm² 0.6/1kV Flame Retardant Copper Cable, XLPE Insulation for Building Power Distribution
Cable Designation & Meaning
|
Code |
Meaning |
|---|---|
|
ZC |
Flame retardant Class C |
|
YJ |
Cross-linked polyethylene (XLPE) insulation |
|
V |
Polyvinyl chloride (PVC) sheath |
|
4×70 mm² |
Four equal cores of 70 mm² copper conductor |
Construction: Four 70 mm² copper conductors (3 phase + 1 neutral), XLPE insulation, PVC outer sheath. No metallic screen/armour as standard (can be added on request).
ZC-YJV 4×70 mm² — LV Flame-Retardant Four-Core Power Cable — Specification
1. Overview & Ratings. ZC-YJV 4×70 is a heavy four-core LV main-feeder cable rated 0.6/1 kV (Um 1.2), 90 °C working, ZC class C PVC sheath: four equal 70 mm² compacted copper cores (L1/L2/L3 phases plus a full neutral), dry-cured XLPE, unarmored. OD ≈ 26 mm, ≈ 3300 kg/km (est.), ≈ 175 A per core free air at 30 °C (est.). Scope: heavy power distribution, workshop main feeders, large motors and pump groups — not 950°C fire duty.
2. Construction Stack (Inner → Outer, expanded).
| Layer / Feature | Build | Function |
|---|---|---|
| Conductors L1/L2/L3/N | 4×70 compacted Cu, Class 2, ≈18 strands | R ≤0.268 Ω/km |
| Strand compaction | Concentric layers rolled compact per core | Compact heavy bundle, clean lugs |
| XLPE insulation (all cores) | Dry-cured PE, ≈1.6 mm | Uniform 90°C dielectric |
| 2+2 core laying | Four equal cores in two rows | Round heavy finished bundle |
| PVC ZC sheath | Class C, ≈1.6 mm overall | Self-extinguishes, prints clear |
| Jacket print | Continuous type/size/voltage/length | On-site readable spec |
3. Electrical Characteristics. All four cores R ≤ 0.268 Ω/km @20 °C. Test 3.5 kV AC / 5 min; ≈ 175 A per core (est., air 30 °C); short-circuit ≈ 8.0 kA / 1 s (est.); 50/60 Hz; unscreened; low-loss XLPE; high stable insulation resistance.
Insulation & Sheath Data
|
Property |
Value |
|---|---|
|
Insulation material |
XLPE (cross-linked polyethylene) |
|
Outer sheath material |
PVC (ST₂) |
|
Long-term service temp. |
90 °C (continuous) |
|
Max. conductor temp. (normal) |
90 °C |
|
Short-circuit temp. (≤5 s) |
250 °C |
|
Emergency overload temp. |
130 °C (≤1 h) |
|
Test voltage AC (5 min) |
3.5 kV |
|
Dielectric strength |
≥ 20 kV/mm |
|
Volume resistivity @20 °C |
≥ 1×10¹⁴ Ω·cm |
|
Shield |
None as standard (can be added) |
Electrical Parameters
|
Parameter |
Value |
Note |
|---|---|---|
|
Rated voltage U₀/U |
0.6 / 1 kV |
GB/T 12706.1 / IEC 60502-1 |
|
Max. system voltage |
1.2 kV AC |
— |
|
Test voltage AC (5 min) |
3.5 kV |
Routine test |
|
DC resistance @20 °C |
≤ 0.268 Ω/km per core |
GB/T 3956 Class 2 Cu max (70 mm²) |
|
AC resistance @90 °C (est.) |
≈ 0.343 Ω/km per core |
— |
|
Current rating in air (30 °C) |
3-phase: 210 A |
4×70, touching, in free air |
|
Current rating in tray (30 °C) |
3-phase: 230 A |
4×70, spaced 2×OD |
|
Current rating buried in ground (20 °C, thermal resistivity 1.2 K·m/W) |
3-phase: 215 A |
direct buried |
|
Current rating in conduit (30 °C) |
3-phase: 185 A |
— |
|
Short-circuit current (1 s, Cu, 250 °C) |
≈ 7.7 kA (7,700 A) per core |
— |
|
Capacitance (core-to-sheath, approx.) |
≈ 0.20 µF/km |
XLPE |
|
Inductive reactance (approx.) |
≈ 0.08 Ω/km |
at 50 Hz |
|
Frequency |
50/60 Hz AC |
— |
Reference values: 4×70 at 210 A three-phase, 400 V → max load ≈ 126 kW (cos φ = 0.8). Suitable for large-medium three-phase distribution with full-size neutral, large industrial motors, and main building sub-main feeders.
4. Thermal & Flame. 90 °C continuous, 250 °C short-time; ZC class C self-extinguishing — flame retardancy, not 950°C integrity; survives large-unit start-stop and feeder cycling; indoor preferred, UV jacket optional.
Temperature Characteristics
|
Property |
Value |
|---|---|
|
Max. conductor operating temp. |
90 °C (continuous) |
|
Max. short-circuit temp. (≤5 s) |
250 °C |
|
Emergency overload temp. |
130 °C (≤1 h) |
|
Min. installation ambient temp. |
0 °C (below 0 °C requires preheating) |
|
Service ambient range |
−20 °C to +90 °C |
|
Flexing temp. range |
0 °C to +90 °C |
Fire Performance (ZC-YJV — Flame Retardant C)
|
Property |
Value / Requirement |
|---|---|
|
Flame retardant |
GB/T 18380.12 / IEC 60332-1-2 (single cable, self-extinguishing) |
|
Flame retardant class |
Class C (ZC) per GB/T 19666 |
|
Halogen content |
Contains halogen (PVC sheath) |
|
Smoke density |
Not low-smoke (PVC) |
|
Corrosivity |
Corrosive (PVC) |
|
Toxicity |
Toxic fumes when burned (PVC) |
|
EMI shielding |
None (no metallic screen/armour) |
5. Installation Practice & Handling. 70 mm² lugs on all four cores, heavy glands to ≈26 mm OD, hydraulic crimp/torque per table; bend ≥ 15×OD ≈ 390 mm; apply duct/tray derating; keep the bundle tidy; verify four-core continuity, phase sequence, neutral and insulation before energizing.
Mechanical & Installation Parameters
|
Parameter |
Value |
Remarks |
|---|---|---|
|
Minimum bending radius |
≥ 15 × OD → ≈ 435 mm at Ø29.0 mm |
four-core unarmoured |
|
Max. pulling tension |
1,050 N per core (70 mm² × 15 N/mm²) |
Cu conductor limit |
|
Direct burial |
Suitable (with sand bedding) |
— |
|
Surface mounting |
Heavy-duty cable tray, ladder, cleats |
— |
|
Conduit ID |
≥ 55 mm |
— |
|
Fixing |
heavy-duty cleats, cable ties |
— |
|
Impact resistance |
Moderate |
— |
|
Water resistance |
Good (PVC sheath) |
— |
|
UV resistance |
Fair (PVC degrades outdoors, use UV-resistant PVC or conduit) |
— |
|
Flex life |
Good (Class 2 stranded) |
fixed installation |
|
Termination note |
Standard compression lugs or mechanical connectors |
— |
6. Typical Service Applications. Heavy three-phase main feeders, large motors, pump groups, plant trunk circuits, sub-distribution boards and vertical riser branches.

7. Testing & QA Regime (16 items). Routine: DC resistance on all four 70 cores, 3.5 kV withstand, insulation resistance, four-core continuity, insulation thickness, sheath thickness, dimensional check, strand construction, eccentricity, core color identification, print legibility, mass, jacket finish, packing inspection. Type: ZC flame test, short-circuit rating, sheath mechanical.
Cable Parameters
| ZR-YJV 4×70 mm² Flame-Retardant Copper-Conductor XLPE-Insulated PVC-Sheathed Power Cable — Product Parameters (0.6/1 kV, Four-Core) | |||||
| Construction: CU / XLPE / PVC, 4 cores • Standards: GB/T 12706.1, IEC 60502-1 (cable), GB/T 3956 (conductor), GB/T 19666 & GB/T 18380 (flame retardance) • Nominal values for reference — confirm against factory test certificate | |||||
| No. | Category | Parameter | Value | Unit | Notes / Standard Reference |
| A. Product Identification | |||||
| 1 | Identification | Product name | Flame-retardant copper-conductor XLPE-insulated PVC-sheathed power cable (four-core) | — | Designation ZR-YJV; "ZR" = flame-retardant, halogen-containing |
| 2 | Identification | Model designation | ZR-YJV 4×70 | — | 4 cores × 70 mm²; Cu / XLPE / PVC |
| 3 | Identification | Design standards | GB/T 12706.1; IEC 60502-1 | — | Conductor: GB/T 3956 / IEC 60228; fire rating: GB/T 19666, GB/T 18380 |
| 4 | Identification | Rated voltage U0/U | 0.6/1 | kV | Max system voltage Um = 1.2 kV |
| 5 | Identification | Rated frequency | 50 | Hz | AC power distribution |
| 6 | Identification | Number of cores | 4 | — | Three phases (L1/L2/L3) + neutral (N) |
| 7 | Identification | Nominal cross-sectional area | 70 | mm² | Per core; nominal section per GB/T 3956 |
| B. Cable Construction (from conductor to outer sheath) | |||||
| 8 | Conductor | Material | Plain annealed copper (Cu) | — | High-conductivity copper |
| 9 | Conductor | Conductor class | Class 1 or Class 2 (typical: Class 2, stranded) | — | GB/T 3956 / IEC 60228 |
| 10 | Conductor | Typical stranding construction (per core) | 19 wires × 2.14 mm (19/2.14) | — | Class 2 round stranded (1+6+12 concentric); 14 × 2.52 also used; nominal 70 mm² per core |
| 11 | Conductor | Conductor diameter (per core) | ≈ 10.70 | mm | Ø of the 19/2.14 stranded core (5 × 2.14) |
| 12 | Conductor | Max. DC resistance of conductor at 20 °C | 0.268 | Ω/km | GB/T 3956, Class 2 copper |
| 13 | Insulation | Material | Cross-linked polyethylene (XLPE) | — | Thermally cross-linked; natural/transparent |
| 14 | Insulation | Nominal insulation thickness | 1.1 | mm | GB/T 12706.1 / IEC 60502-1 (0.6/1 kV, 70 mm²) |
| 15 | Insulation | Diameter over insulation (per core) | ≈ 12.90 | mm | ≈ 10.70 + 2 × 1.1 (calculated) |
| 16 | Lay-up | Core assembly | Four insulated cores laid up around a central non-hygroscopic filler; binder tape over the bundle | — | Round construction; classic 4-core geometry |
| 17 | Sheath | Material | Flame-retardant polyvinyl chloride (PVC, ST2 type) | — | Colour: black (or as ordered) |
| 18 | Sheath | Nominal sheath thickness | 1.9 | mm | GB/T 12706.1 / IEC 60502-1 (Mingda four-core table) |
| 19 | Dimensions | Approx. overall diameter | ≈ 36.4 | mm | Mingda 36.4 (four-core unarmored) |
| 20 | Dimensions | Approx. cable weight | ≈ 3080 | kg/km | Mingda 3080 (aluminium version ≈ 1331 kg/km) |
| C. Electrical Performance | |||||
| 21 | Electrical | Max. DC conductor resistance at 20 °C | 0.268 | Ω/km | GB/T 3956; routine measurement (per core) |
| 22 | Electrical | Power-frequency withstand voltage (routine test) | 3.5 kV / 5 min, no breakdown | — | AC 50 Hz; per GB/T 12706.1 / IEC 60502-1 |
| 23 | Electrical | Insulation resistance (finished cable, 20 °C) | ≥ 36.7 | MΩ·km | Typical finished-cable reference for 0.6/1 kV XLPE cables |
| 24 | Electrical | XLPE volume resistivity at 20 °C | ≥ 1 × 10¹² | Ω·cm | Material-level requirement (manufacturer reference) |
| 25 | Electrical | Capacitance (approx., per core) | ≤ 0.45 | μF/km | Manufacturer reference value |
| 26 | Electrical | Reference ampacity — in air, 25 °C, four cores loaded | ≈ 200 | A | Mingda 200 A; Lvbao 4×70+1×35 also 200 A @25 °C |
| 27 | Electrical | Reference ampacity — direct burial, 25 °C | ≈ 225 | A | Mingda 225 A; Lvbao 4×70+1×35 225 A; soil thermal resistivity dependent |
| D. Thermal Performance | |||||
| 28 | Thermal | Max. continuous conductor temperature | 90 | °C | XLPE insulation temperature class |
| 29 | Thermal | Max. conductor temperature under short-circuit (≤ 5 s) | 250 | °C | Per GB/T 12706.1 / IEC 60502-1 |
| 30 | Thermal | Ambient service temperature range | -20 to +45 | °C | Per manufacturer datasheet family; check project specification |
| 31 | Thermal | Min. installation (laying) temperature | 0 | °C | Pre-heat the cable if ambient is below 0 °C |
| E. Flame Retardance (ZR) | |||||
| 32 | Flame retardance | Flame-retardant class | ZC (class C) by default for "ZR" | — | GB/T 19666; ZA / ZB available on request; halogen-containing PVC (not LSZH) |
| 33 | Flame retardance | Single-cable vertical flame-spread test | Pass | — | GB/T 18380.12 |
| 34 | Flame retardance | Bunched flame-spread test (class C) | Char extent ≤ 2.5 m above burner bottom edge | — | GB/T 18380.35: non-metallic volume ≥ 1.5 L/m; flame application 20 min |
| 35 | Flame retardance | Halogen content | Halogen-containing (PVC) | — | For low-smoke, zero-halogen requirement select WDZ-YJY (LSZH) type |
| F. Installation | |||||
| 36 | Installation | Min. bending radius — multi-core cable | ≥ 15 × OD | — | GB 50168 practice for multi-core XLPE cables |
| 37 | Installation | Laying methods | Conduit, tray, cable trench, duct, building trunking, supported/suspended aerial | — | Direct burial with mechanical protection where permitted |
| 38 | Installation | Site withstand test after installation | DC 4U0 = 2.4 kV, 15 min (recommended) | — | Per utility procurement standard Q/GDW 13244.1-2018 |
| G. Packing & Delivery | |||||
| 39 | Packing | Standard delivery length | 100 m per coil/drum (or as ordered) | — | Typical industry practice; custom lengths available |
| 40 | Packing | Cable marking | Model, rated voltage, manufacturer, year of manufacture, sequential length marks | — | Per GB/T 6995 / project specification |
| 41 | Packing | Packing form | Coil (carton drum) / wooden drum / export packing | — | As per customer requirement |
Cable Test Parameters
| ZR-YJV 4×70 mm² — Test / Verification Parameters (per GB/T 12706.1 & IEC 60502-1) | ||||
| Test Stage | Test Item | Method / Standard | Requirement / Acceptance Criterion | Notes |
| Routine test | Conductor DC resistance measurement | GB/T 3956 (IEC 60228) | ≤ 0.268 Ω/km at 20 °C (per core) | Measured on every production length |
| Routine test | Power-frequency withstand voltage | GB/T 12706.1 / IEC 60502-1 | 3.5 kV AC, 5 min, no breakdown | Applied between each conductor and earth/water; 50 Hz |
| Routine test | Construction check — insulation & sheath thickness, outer diameter | GB/T 2951 | Within GB/T 12706.1 tolerances | Insulation ≥ 1.1 mm nominal; sheath ≥ 1.9 mm nominal |
| Sample test | Hot set (thermal elongation) test — XLPE insulation | GB/T 12706.1 §16.3.13 / GB/T 2951.11 | 200 ± 3 °C, 15 min, stress 0.2 MPa: elongation under load ≤ 175 %; permanent elongation after cooling ≤ 15 % | Verifies degree of cross-linking |
| Sample test | Conductor construction & diameter check | GB/T 3956 | Class 2; 19 × 2.14 mm; Ø ≈ 10.70 mm | Sampled per batch |
| Type test | Single-cable vertical flame-spread test (flame retardance) | GB/T 18380.12 | No flame spread; charring does not reach top reference point | ZR / ZC flame-retardant property |
| Type test | Bunched flame-spread test, class C | GB/T 18380.35 | Char extent ≤ 2.5 m above burner bottom edge; flame application 20 min; non-metallic volume ≥ 1.5 L/m | Class ZC per GB/T 19666 |
| Type test | Bending test (mechanical) | GB/T 12706.1 | Bend around specified mandrel without insulation/sheath damage | Mandrel diameter related to cable OD (multi-core) |
| Post-installation | DC withstand test after installation | Q/GDW 13244.1-2018 (recommended practice) | 4U0 = 2.4 kV DC, 15 min, no breakdown | For new installations; verify project specification |
| Optional | Insulation resistance measurement at 20 °C | Manufacturer test method | ≥ 36.7 MΩ·km (typical finished-cable value) | Not a routine item in GB/T 12706.1; confirm with factory |
| Optional | XLPE volume resistivity at 20 °C | Manufacturer / material test | ≥ 1 × 10¹² Ω·cm | Material-level reference |
Cable Cross Section Structure

| ZR-YJV 4×70 mm² — Cable Cross-Section Structure (Schematic) | |||||
| Four-core construction from conductor to outer sheath · nominal values per GB/T 12706.1 / IEC 60502-1 · not to exact scale | |||||
| No. | Layer | Material / Construction | Nominal Thickness (mm) | Diameter (mm) | Function / Remarks |
| 1 | Conductor (Cu) × 4 | Annealed copper, Class 2 stranded — 19 × 2.14 mm per core (19/2.14, 1+6+12), nominal 70 mm² per core | — | ≈ 10.70 (Ø per core) | Current-carrying element; max DC resistance ≤ 0.268 Ω/km @ 20 °C (per core) |
| 2 | Insulation (XLPE) × 4 | Cross-linked polyethylene | 1.1 | ≈ 12.90 (Ø per core, over insulation) | Dielectric barrier; rated 90 °C continuous; withstands 3.5 kV / 5 min |
| 3 | Core lay-up | Four insulated cores laid up around central non-hygroscopic filler; binder tape | — | ≈ 31.1 (Ø over lay-up, calc.) | Forms a round assembly for sheathing |
| 4 | Outer sheath (PVC) | Flame-retardant PVC, ST2 type, black | 1.9 | ≈ 36.4 (Ø overall) | Mechanical & moisture protection; flame retardance ZC (ZR) per GB/T 19666 |
| Key Dimensions & Properties | |||||
| Overall diameter | ≈ 36.4 | mm | Mingda four-core unarmored table | ||
| Approx. cable weight | ≈ 3080 | kg/km | Mingda 3080 (Al ≈ 1331) | ||
| Rated voltage | 0.6/1 | kV | AC 50 Hz; max system voltage Um = 1.2 kV | ||
| Max conductor temperature | 90 / 250 | °C | Continuous / short-circuit (≤ 5 s) | ||
| Min. bending radius (multi-core) | ≥ 15 × OD | — | OD = actual cable diameter | ||
| Flame-retardant class | ZC (ZR) | — | GB/T 19666 | ||
| Schematic — not to exact scale. Nominal values for reference; confirm against factory test certificate. | |||||
Product Structure Introduction
| Product Structure Introduction — ZR-YJV 4×70 mm² | |||
| Four-core layered construction description, from conductor to outer sheath · per GB/T 12706.1 & IEC 60502-1 · CU / XLPE / PVC · 0.6/1 kV | |||
| 1. Product Introduction | |||
| ZR-YJV 4×70 is a flame-retarded four-core power cable rated 0.6/1 kV AC, following the copper / XLPE / PVC platform and the requirements of GB/T 12706.1 / IEC 60502-1, with stranding in accordance with GB/T 3956 / IEC 60228 and fire classification under GB/T 19666 (ZC default). Approx. outside diameter 36.4 mm, weight 3080 kg/km; standard delivery on 100 m coils or drums. | |||
| Four equal 70 mm² cores give the cable a high continuous current of 200 A in air while keeping the neutral full-sized for unbalanced three-phase loads. | |||
| 2. Conductor Structure | |||
| The 70 mm² core is stranded concentrically from nineteen 2.14 mm annealed copper wires — 19/2.14 in a 1+6+12 arrangement, Class 2 — forming ≈ 10.70 mm diameter. Maximum DC resistance is 0.268 Ω/km at 20 °C. Where the manufacturer prefers, 14 × 2.52 is an equivalent alternative stranding of the same class. | |||
| 3. Insulation Structure | |||
| Insulation thickness rises to 1.1 mm at this section, putting the over-insulation diameter at ≈ 12.90 mm per core. XLPE provides a continuous rating of 90 °C, a five-second short-circuit capability at 250 °C, volume resistivity of at least 1×10¹² Ω·cm, and clearance of the routine 3.5 kV AC, five-minute proof test. | |||
| 4. Assembly, Sheath & Fire | |||
| The four insulated cores are cabled around a dry central filler into a round assembly of about 31.1 mm and bound with tape, then covered by a 1.9 mm flame-retarded ST2 PVC jacket to finish at ≈ 36.4 mm. ZC flame behaviour is demonstrated under GB/T 18380.12 and GB/T 18380.35; PVC being halogen-bearing, LSZH applications call for WDZ-YJY instead. | |||
| 5. Site & Handling Notes | |||
| • Respect a minimum bending radius of 15 × OD. • Run the DC 4U0 = 2.4 kV / 15 min site test before energising. • Ambient −20 to +45 °C; warm drums when pulling below 0 °C. • Derate the quoted ampacity for ambient, grouping and burial. • Fit lugs and glands for the ≈ 10.70 mm core. |
8. Factory Advantages.
- Equal-size four-core build — full neutral handles large-unit unbalance and harmonic return without extra selection.
- Stable XLPE cure — even cross-linking keeps the 90°C dielectric consistent on long main feeders.
- Dosed ZC compound — self-extinguishing jacket protects switchrooms and plant rooms from flame spread.
- Length-on-demand — cut to exact main feeder meter with sealed ends.
- Uniform resistance log — all four 70 cores' R recorded to lot for balanced performance.
- Continuous print line — type, size, ZC, voltage and length readable along the feeder run.
- Phase-color option — L1/L2/L3/N colors reduce wiring errors at main switchboards.
- Heavy drum pack — heavy section on a rated wooden drum, both ends moisture-sealed.
- Certified QA pack — routine + type test record shipped per batch for commissioning.

9. Packaging, Storage & Logistics. Cut to measured main feeder length on a heavy wooden drum with sealed ends; continuous marking; store dry indoor on drum supports, shaded, avoid direct UV.

10. Procurement Specification. State "ZC-YJV 4×70", length, class C, phase colors; note the full neutral for large-unit unbalance and not fire-rated; request the four-core resistance log and 16-item QA record. Est. values confirmed against the factory certificate.
11. Cable Industry FAQ.
- Q1: How does 4×70 differ from 4×16? A size up: cores 70 vs 16 mm²; OD 26 vs 14 mm, mass 3300 vs 950 kg/km, current 175 vs 65 A, resistance 0.268 vs 1.15 Ω/km; built for heavy workshop main feeders rather than small lighting branches.
- Q2: Why a full-size neutral? Large units and drives draw neutral current and harmonics; an equal 70 neutral prevents overheating.
- Q3: Is ZC fire-resistant? No. Class C self-extinguishes; it does not hold live at 950°C/180min.
- Q4: DC resistance values? All four 70 mm² cores ≤0.268 Ω/km at 20°C.
- Q5: Screen or armor? Unscreened standard; add braid near VFD EMI; steel-tape armor for buried ground-crushing duty.
- Q6: Current per core? ≈175 A (est.) free air 30°C; derate in crowded ducts.
- Q7: Bending? ≈390 mm (15×OD); use bending tools and sheaves.
- Q8: Connectors? 70 mm² lugs on L1/L2/L3/N; gland to ≈26 mm OD.
- Q9: Indoor or outdoor? Indoor preferred; specify UV-stabilized jacket for exposed runs.
- Q10: Packing? Heavy wooden drum with moisture-sealed ends.
- Q11: What proof ships? Four-core resistance log + 16-test record; est. values confirmed against certificate.