logo
Anhui Tongdu International Trade Co., Ltd.
Online Service

Online Service

Contact Person
+86 19056002718
WeChat QR Code
Follow Us

Medium Voltage Power Cable

Quality YJV22 Medium Voltage Power Cable 3x150mm2 Copper Mv Armoured Cable 15kV factory

YJV22 Medium Voltage Power Cable 3x150mm2 Copper Mv Armoured Cable 15kV

YJV22 3x150mm² Copper XLPE Armored MV Cable 8.7/15kV Reliable Underground Power Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath 22 Steel tape armoured (double steel tape) 3×150 mm² Three cores, each 150 mm² copper Construction: Copper ...

Quality 3x400mm2 Medium Voltage Cable  XLPE Armored  XLPE Wire 26KV 35kV factory

3x400mm2 Medium Voltage Cable XLPE Armored XLPE Wire 26KV 35kV

YJLV22 3x400mm² Aluminum XLPE Armored HV Cable 26/35kV for Urban Power Distribution Cable Designation & Meaning Code Meaning 26/35 kV Rated voltage: U₀ = 26 kV (phase-to-earth), U = 35 kV (phase-to-phase) YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Lü = aluminium) V PVC ...

Quality 3x400mm2 Medium Voltage Power Cable Aluminum XLPE  Armored Mv Cable 8.7kV factory

3x400mm2 Medium Voltage Power Cable Aluminum XLPE Armored Mv Cable 8.7kV

YJLV22 3x400mm² Aluminum XLPE Armored MV Cable 8.7/15kV Cost Effective Underground Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Lü = aluminium) V PVC outer sheath 22 Steel tape armoured (double steel tape) 3×400 mm² Three cores, each ...

Quality 8.7KV 10kV  Mv Power Cable Armored  Skyscraper Main Aluminum Cable factory

8.7KV 10kV Mv Power Cable Armored Skyscraper Main Aluminum Cable

Skyscraper Main Aluminum Cable YJLV22 3x400mm2 8.7/10kV 8.7/15kV Armored MV Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor​ (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 ...

Quality 3x300mm2 Medium Voltage Power Cable Al XLPE Super Heavy Aluminum Cable factory

3x300mm2 Medium Voltage Power Cable Al XLPE Super Heavy Aluminum Cable

Super Heavy Aluminum Cable YJLV22 3x300mm² 8.7/10kV 8.7/15kV Armored XLPE MV Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor​ (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7...

Quality 3x240mm2 Flexible Medium Voltage Cable 8.7kV 15kV 3 Core Cable factory

3x240mm2 Flexible Medium Voltage Cable 8.7kV 15kV 3 Core Cable

XLPE Medium Voltage Aluminum Cable YJLV22 3x240mm2 8.7/15kV Armored 3 Core Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor​ (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 ...

Quality 3 Core Medium Voltage Power Cable Heavy Duty 185mm2 Armored XLPE Cable factory

3 Core Medium Voltage Power Cable Heavy Duty 185mm2 Armored XLPE Cable

Heavy Duty Aluminum Cable 3 Core 185mm² YJLV22 8.7/10kV Armored XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor​ (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...

Quality High Capacity Mv Armoured Cable 150mm2 XLPE 3 Core Aluminum Cable factory

High Capacity Mv Armoured Cable 150mm2 XLPE 3 Core Aluminum Cable

High Capacity Aluminum Cable 3 Core 150mm² YJLV22 8.7/10kV Armored XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor​ (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...

Quality 3x120mm2 Medium Voltage Power Cable 8.7kV 15kV Aluminum Mc Cable factory

3x120mm2 Medium Voltage Power Cable 8.7kV 15kV Aluminum Mc Cable

Industrial Main Aluminum Cable YJLV22 3x120mm² 8.7/15kV Armored MV Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor​ (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated ...

Prev 1 2 3 Next