ZR-YJV 4×50mm² 0.6/1kV Flame Retardant Copper Cable, XLPE Insulation for Building Power Distribution

ZR-YJV 4×50mm² 0.6/1kV Flame Retardant Copper Cable, XLPE Insulation for Building Power Distribution

Basic Properties

country of origin
China
brand name
TD
certificate
CE/ISO/CCC
product model
ZR-YJV 4×50mm²

Trading Properties

moq
1 Meter
payment method
L/C,T/T
supply capacity
10000 meters per month

Product Summary

ZR-YJV 4×50mm² 0.6/1kV Flame Retardant Copper Cable, XLPE Insulation for Building Power Distribution Technical Datasheet — ZR-YJV 0.6/1 kV 4×50 mm² Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ ...

Product Details

Highlight:

zr-yjv 4 cores cable

,

zr-yjv 25 sq mm 4 core cable

,

1kv 4 cores cable

Conductor (×4):
Bare Annealed Copper, Class 2 Stranded, 19×∅1.78 Mm, Conductor Ø ≈ 9.0 Mm
Conductor nominal area (per core):
50 Mm²
Number of cores:
4
Conductor construction:
Class 2, 19×∅1.78 Mm,min. 19 Wires
Conductor diameter (approx.):
9.0mm
Insulation (×4):
XLPE
Insulation thickness:
1.0 Mm (50 Mm² Class)
Diameter over insulated core:
11.0 Mm,9.0 + 2×1.0
Filler / binder:
FR PP Filler + FR Tape
Outer sheath:
Flame-retardant PVC (ZR Grade)
Sheath thickness:
1.8 Mm (multi-core Rule, ≥1.8 Mm)
Overall cable diameter:
26.0 – 27.5 Mm
Approx. weight:
1080 – 1200 Kg/km
Long-term service temp.:
90 °C
Short-circuit temp. (≤5 s):
250 °C
Emergency overload:
105–130 °C
Routine test:
3.5 KV AC / 5 Min; Type Test 4.0 KV
Volume resistivity @90 °C:
≥ 10¹² Ω·cm

Product Description

ZR-YJV 4×50mm² 0.6/1kV Flame Retardant Copper Cable, XLPE Insulation for Building Power Distribution


Technical Datasheet — ZR-YJV 0.6/1 kV 4×50 mm²


ZR-YJV 4×50mm² 0.6/1kV Flame Retardant Copper Cable, XLPE Insulation for Building Power Distribution

  1. Cable Designation & Meaning

Code

Meaning

ZR

Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC).

YJ

XLPE (cross-linked polyethylene) insulation

V

PVC outer sheath — flame-retardant grade, contains halogen (Cl)

0.6/1 kV

Rated voltage U₀/U = 600/1000 V; Uₘ = 1.2 kV

4×50 mm²

Four cores, nominal copper conductor area 50 mm² per core


Construction: Unarmoured, non-screened, round multi-core

Note: Four-core = three-phase AC with neutral (L1+L2+L3+N) or (L1+L2+L3+PE) with equal conductor sizes. All cores are 50 mm² copper.

  1. Applicable Standards
  • GB/T 12706.1-2020 (equiv. IEC 60502-1)
  • GB/T 3956 / IEC 60228 — Conductors (Class 2)
  • GB/T 19666-2019 — Flame retardant (ZR = Class C)
  • GB/T 18380.3 — Bunched flame test, Class C (char ≤ 2.5 m)
  • GB/T 17651 / IEC 61034 — Smoke density (PVC → heavy smoke, not low-smoke)
  • GB/T 17650 / IEC 60754 — Halogen content (PVC contains Cl)


ZR-YJV 4×50 mm² Flame-Retardant Copper-Conductor XLPE-Insulated PVC-Sheathed Power Cable — Product Parameters (0.6/1 kV, Four-Core)
Construction: CU / XLPE / PVC, 4 cores  •  Standards: GB/T 12706.1, IEC 60502-1 (cable), GB/T 3956 (conductor), GB/T 19666 & GB/T 18380 (flame retardance)  •  Nominal values for reference — confirm against factory test certificate
No. Category Parameter Value Unit Notes / Standard Reference
A. Product Identification
1 Identification Product name Flame-retardant copper-conductor XLPE-insulated PVC-sheathed power cable (four-core) — Designation ZR-YJV; "ZR" = flame-retardant, halogen-containing
2 Identification Model designation ZR-YJV 4×50 — 4 cores × 50 mm²; Cu / XLPE / PVC
3 Identification Design standards GB/T 12706.1; IEC 60502-1 — Conductor: GB/T 3956 / IEC 60228; fire rating: GB/T 19666, GB/T 18380
4 Identification Rated voltage U0/U 0.6/1 kV Max system voltage Um = 1.2 kV
5 Identification Rated frequency 50 Hz AC power distribution
6 Identification Number of cores 4 — Three phases (L1/L2/L3) + neutral (N)
7 Identification Nominal cross-sectional area 50 mm² Per core; nominal section per GB/T 3956
B. Cable Construction (from conductor to outer sheath)
8 Conductor Material Plain annealed copper (Cu) — High-conductivity copper
9 Conductor Conductor class Class 1 or Class 2 (typical: Class 2, stranded) — GB/T 3956 / IEC 60228
10 Conductor Typical stranding construction (per core) 10 wires × 2.52 mm (10/2.52) — Class 2 round stranded; nominal section 50 mm² per core (10-wire construction)
11 Conductor Conductor diameter (per core) ≈ 8.40 mm Ø of the 10/2.52 stranded core
12 Conductor Max. DC resistance of conductor at 20 °C 0.387 Ω/km GB/T 3956, Class 2 copper
13 Insulation Material Cross-linked polyethylene (XLPE) — Thermally cross-linked; natural/transparent
14 Insulation Nominal insulation thickness 1.0 mm GB/T 12706.1 / IEC 60502-1 (0.6/1 kV, 50 mm²; steps up from 0.9 at 35 mm²)
15 Insulation Diameter over insulation (per core) ≈ 10.40 mm ≈ 8.40 + 2 × 1.0 (calculated)
16 Lay-up Core assembly Four insulated cores laid up around a central non-hygroscopic filler; binder tape over the bundle — Round construction; classic 4-core geometry
17 Sheath Material Flame-retardant polyvinyl chloride (PVC, ST2 type) — Colour: black (or as ordered)
18 Sheath Nominal sheath thickness 1.8 mm GB/T 12706.1 / IEC 60502-1 (Mingda four-core table)
19 Dimensions Approx. overall diameter ≈ 31.0 mm Mingda 31.0 (four-core unarmored)
20 Dimensions Approx. cable weight ≈ 2172 kg/km Mingda 2172 (aluminium version ≈ 961.1 kg/km)
C. Electrical Performance
21 Electrical Max. DC conductor resistance at 20 °C 0.387 Ω/km GB/T 3956; routine measurement (per core)
22 Electrical Power-frequency withstand voltage (routine test) 3.5 kV / 5 min, no breakdown — AC 50 Hz; per GB/T 12706.1 / IEC 60502-1
23 Electrical Insulation resistance (finished cable, 20 °C) ≥ 36.7 MΩ·km Typical finished-cable reference for 0.6/1 kV XLPE cables
24 Electrical XLPE volume resistivity at 20 °C ≥ 1 × 10¹² Ω·cm Material-level requirement (manufacturer reference)
25 Electrical Capacitance (approx., per core) ≤ 0.45 μF/km Manufacturer reference value
26 Electrical Reference ampacity — in air, 25 °C, four cores loaded ≈ 160 A Mingda 160 A; Lvbao 4×50+1×25 also 160 A @25 °C
27 Electrical Reference ampacity — direct burial, 25 °C ≈ 185 A Mingda 185 A; Lvbao 4×50+1×25 185 A; soil thermal resistivity dependent
D. Thermal Performance
28 Thermal Max. continuous conductor temperature 90 °C XLPE insulation temperature class
29 Thermal Max. conductor temperature under short-circuit (≤ 5 s) 250 °C Per GB/T 12706.1 / IEC 60502-1
30 Thermal Ambient service temperature range -20 to +45 °C Per manufacturer datasheet family; check project specification
31 Thermal Min. installation (laying) temperature 0 °C Pre-heat the cable if ambient is below 0 °C
E. Flame Retardance (ZR)
32 Flame retardance Flame-retardant class ZC (class C) by default for "ZR" — GB/T 19666; ZA / ZB available on request; halogen-containing PVC (not LSZH)
33 Flame retardance Single-cable vertical flame-spread test Pass — GB/T 18380.12
34 Flame retardance Bunched flame-spread test (class C) Char extent ≤ 2.5 m above burner bottom edge — GB/T 18380.35: non-metallic volume ≥ 1.5 L/m; flame application 20 min
35 Flame retardance Halogen content Halogen-containing (PVC) — For low-smoke, zero-halogen requirement select WDZ-YJY (LSZH) type
F. Installation
36 Installation Min. bending radius — multi-core cable ≥ 15 × OD — GB 50168 practice for multi-core XLPE cables
37 Installation Laying methods Conduit, tray, cable trench, duct, building trunking, supported/suspended aerial — Direct burial with mechanical protection where permitted
38 Installation Site withstand test after installation DC 4U0 = 2.4 kV, 15 min (recommended) — Per utility procurement standard Q/GDW 13244.1-2018
G. Packing & Delivery
39 Packing Standard delivery length 100 m per coil/drum (or as ordered) — Typical industry practice; custom lengths available
40 Packing Cable marking Model, rated voltage, manufacturer, year of manufacture, sequential length marks — Per GB/T 6995 / project specification
41 Packing Packing form Coil (carton drum) / wooden drum / export packing — As per customer requirement


Test Parameters


ZR-YJV 4×50 mm² — Test / Verification Parameters (per GB/T 12706.1 & IEC 60502-1)
Test Stage Test Item Method / Standard Requirement / Acceptance Criterion Notes
Routine test Conductor DC resistance measurement GB/T 3956 (IEC 60228) ≤ 0.387 Ω/km at 20 °C (per core) Measured on every production length
Routine test Power-frequency withstand voltage GB/T 12706.1 / IEC 60502-1 3.5 kV AC, 5 min, no breakdown Applied between each conductor and earth/water; 50 Hz
Routine test Construction check — insulation & sheath thickness, outer diameter GB/T 2951 Within GB/T 12706.1 tolerances Insulation ≥ 1.0 mm nominal; sheath ≥ 1.8 mm nominal
Sample test Hot set (thermal elongation) test — XLPE insulation GB/T 12706.1 §16.3.13 / GB/T 2951.11 200 ± 3 °C, 15 min, stress 0.2 MPa: elongation under load ≤ 175 %; permanent elongation after cooling ≤ 15 % Verifies degree of cross-linking
Sample test Conductor construction & diameter check GB/T 3956 Class 2; 10 × 2.52 mm; Ø ≈ 8.40 mm Sampled per batch
Type test Single-cable vertical flame-spread test (flame retardance) GB/T 18380.12 No flame spread; charring does not reach top reference point ZR / ZC flame-retardant property
Type test Bunched flame-spread test, class C GB/T 18380.35 Char extent ≤ 2.5 m above burner bottom edge; flame application 20 min; non-metallic volume ≥ 1.5 L/m Class ZC per GB/T 19666
Type test Bending test (mechanical) GB/T 12706.1 Bend around specified mandrel without insulation/sheath damage Mandrel diameter related to cable OD (multi-core)
Post-installation DC withstand test after installation Q/GDW 13244.1-2018 (recommended practice) 4U0 = 2.4 kV DC, 15 min, no breakdown For new installations; verify project specification
Optional Insulation resistance measurement at 20 °C Manufacturer test method ≥ 36.7 MΩ·km (typical finished-cable value) Not a routine item in GB/T 12706.1; confirm with factory
Optional XLPE volume resistivity at 20 °C Manufacturer / material test ≥ 1 × 10¹² Ω·cm Material-level reference


  1. Product Components / Construction (inside → outside)

Layer

Description

Conductor (×4)

Bare annealed copper, Class 2 stranded, 19×∅1.78 mm, conductor Ø ≈ 9.0 mm

Conductor screen

Omitted (not required for 0.6/1 kV)

Insulation (×4)

XLPE, colours: brown/black/grey/blue or red/yellow/blue/green-yellow etc.

Insulation thickness

1.0 mm (50 mm² class)

Filler

Flame-retardant PP/PE to form round assembly

Binder

Flame-retardant tape over laid-up cores

Outer sheath

Flame-retardant PVC (ZR grade)

Sheath thickness

1.8 mm (multi-core rule, ≥1.8 mm)

Sheath colour

Black (standard)

Armour

None

Metallic screen

None

  1. Dimensional Data

Item

Typical value

Remarks

Conductor nominal area (per core)

50 mm²

—

Number of cores

4

—

Conductor construction

Class 2, 19×∅1.78 mm

min. 19 wires

Conductor diameter (approx.)

9.0 mm

—

Insulation thickness

1.0 mm

—

Diameter over insulated core

11.0 mm

9.0 + 2×1.0

Filler / binder

FR PP filler + FR tape

round assembly

Sheath thickness

1.8 mm

multi-core

Overall cable diameter

26.0 – 27.5 mm

use 26.8 mm for design

Approx. weight

1080 – 1200 kg/km

use ≈ 1140 kg/km

Cable shape

Round

—

  1. Insulation Data
  • Material: XLPE
  • Nominal thickness: 1.0 mm
  • Long-term service temp.: 90 °C
  • Short-circuit temp. (≤5 s): 250 °C
  • Emergency overload: 105–130 °C
  • Routine test: 3.5 kV AC / 5 min; type test 4.0 kV
  • Volume resistivity @90 °C: ≥ 10¹² Ω·cm
Insulation Test Data
ZR-YJV  0.6/1 kV  4 × 50 mm²  (Cu / XLPE / FR-PVC)
1.  Cable Identification
Item Description Standard / Note
Designation ZR-YJV 0.6/1 kV 4×50 mm² GB/T 12706.1-2020
Conductor Bare annealed copper, Class 2 stranded, 19×∅1.78 mm GB/T 3956 / IEC 60228
Insulation XLPE (cross-linked polyethylene), 1.0 mm nominal GB/T 12706.1-2020
Outer sheath Flame-retardant PVC (ZR grade), 1.8 mm nominal, black GB/T 19666-2019
Rated voltage U₀/U 0.6 / 1 kV (Uₘ = 1.2 kV) IEC 60502-1
Number of cores 4 (three-phase L1+L2+L3+N or L1+L2+L3+PE, equal sizes) —
2.  Insulation Design Data  (CORE)
Parameter Value Remarks
Insulation material XLPE (cross-linked polyethylene) —
Nominal thickness (eₙ) 1.0 mm 50 mm² class
Minimum allowable thickness (e_min) 0.80 mm eₙ − 0.20 mm (GB/T 12706.1-2020, Table 3)
Insulator colours Brown/black/grey/blue or red/yellow/blue/green-yellow (or as specified) IEC 60446
Volume resistivity @ 90 °C ≥ 10¹² Ω·cm —
Dielectric loss factor (tan δ) @ 20 °C ≤ 1 × 10⁻³ reference
Relative permittivity (εᵣ) ≈ 2.3 – 2.5 reference
Long-term service temp. 90 °C GB/T 12706.1-2020
Short-circuit temp. (≤ 5 s) 250 °C IEC 60502-1
Emergency overload temp. 105 – 130 °C transient
Diameter over insulated core 11.0 mm conductor 9.0 + 2×1.0
3.  Thermal Characteristics
Property Value Remarks
Max. conductor operating temp. (normal) 90 °C long-term
Max. conductor temp. — short-circuit (≤ 5 s) 250 °C IEC 60502-1
Emergency overload temp. 105 °C (up to 130 °C transient) —
Min. installation ambient temp. 0 °C (pre-heat below 0 °C) —
Service ambient range (PVC sheath) −15 °C to +90 °C —
Flame retardant class (sheath) Class C (ZR per GB/T 19666) —
4.  Insulation Test Schedule
Test Item Test Value / Condition Result
Routine withstand test (AC) 3.5 kV AC, 5 min — no breakdown PASS
Type test voltage 4.0 kV AC PASS (IEC 60502-1)
Partial discharge test ≤ 10 pC @ 1.73 U₀ (1.73 kV) PASS (XLPE)
Insulation resistance (IR) ≥ 10⁴ MΩ·km @ 20 °C (reference) PASS
Hot-set test (XLPE cross-linking) 200 °C, 15 min, load 0.2 N/mm² — elongation ≤ 175 %, permanent set ≤ 15 % PASS (IEC 60811-507)
Aging test (air oven) 135 °C, 168 h — tensile strength / elongation retained ≥ 80 % PASS
Tensile strength (insulation) ≥ 12.5 MPa (XLPE, before aging) PASS
Elongation at break (insulation) ≥ 200 % (XLPE, before aging) PASS
Cold bend test −15 °C, 4 h — no cracking PASS
Water absorption ≤ 1 mg/cm² (85 °C, 336 h, reference) PASS
Breakdown voltage (insulation) ≥ 20 kV/mm (reference) PASS
DC resistance of conductor @ 20 °C ≤ 0.387 Ω/km (Class 2 Cu, per core) PASS (GB/T 3956)
Dielectric loss (tan δ) measurement ≤ 1 × 10⁻³ @ 20 °C PASS (reference)
Spark test (during production) 6 – 10 kV (online), pinhole detection PASS
Thickness measurement (microscopic) eₙ = 1.0 mm; e_min ≥ 0.80 mm PASS
5.  Electrical Parameters
Parameter Value Note
Rated voltage U₀/U 0.6 / 1 kV Uₘ = 1.2 kV
Test voltage AC (5 min, routine) 3.5 kV IEC 60502-1
Type-test voltage 4.0 kV IEC 60502-1
DC resistance @ 20 °C (per core) ≤ 0.387 Ω/km GB/T 3956 / IEC 60228, Class 2 max
AC resistance @ 90 °C (est.) ≈ 0.503 Ω/km per core
Current rating — in air (30 °C, single circuit) ≈ 120–135 A (design ≈ 128 A) 4-core
Current rating — direct buried (20 °C, soil 1.0 K·m/W, 0.7 m) ≈ 148–165 A (design ≈ 156 A) 4-core
Short-circuit current (1 s, Cu, 250 °C, per core) ≈ 5.00 kA reference
Frequency 50/60 Hz AC —
6.  Dimensional / Inspection Result
Item Design / Limit Measured (example)
Conductor construction Class 2, 19×∅1.78 mm 19×1.78 mm
Conductor diameter ≈ 9.0 mm 8.9 mm
Insulation thickness (each core) 1.0 mm (min. 0.80 mm) 1.02 / 1.01 / 1.00 / 0.99 mm
Diameter over insulated core 11.0 mm 10.9 mm
Sheath thickness 1.8 mm (min. 1.5 mm) 1.82 mm
Overall cable diameter 26.0 – 27.5 mm (design 26.8) 26.7 mm
DC resistance @ 20 °C (per core) ≤ 0.387 Ω/km 0.382 Ω/km
Approx. weight 1080 – 1200 kg/km (≈ 1140) 1138 kg/km
Footnotes
1. All tests performed at ambient 20 ± 5 °C and 45–75 % RH unless otherwise stated.
2. Routine tests: withstand (3.5 kV / 5 min), conductor resistance, dimensional check. Type tests: 4.0 kV, partial discharge, hot-set, aging, mechanical (per IEC 60502-1).
3. Test values marked “reference” are typical design values — confirm against manufacturer test report / GB/T 12706.1-2020.
4. Insulation thickness for 50 mm² class = 1.0 mm nominal (GB/T 12706.1-2020, Table 3); minimum = 1.0 − 0.20 = 0.80 mm.
5. For low-smoke halogen-free → use WDZ-YJY 4×50; for fire-survival → NH-ZR-YJV 4×50; for armoured → ZR-YJV22 4×50.


  1. Electrical Parameters

Parameter

Value

Note

Rated voltage U₀/U

0.6 / 1 kV

Uₘ = 1.2 kV

Test voltage AC (5 min)

3.5 kV

Routine

Type-test voltage

4.0 kV

IEC 60502

DC resistance @20 °C (Class 2 Cu, per core)

≤ 0.387 Ω/km

GB/T 3956 max

AC resistance @90 °C (est.)

≈ 0.503 Ω/km

per core

Current rating in air (30 °C, single circuit, 4-core)

≈ 120 – 135 A

design ≈ 128 A

Direct buried (20 °C, soil 1.0 K·m/W, 0.7 m)

≈ 148 – 165 A

design ≈ 156 A

Short-circuit current (1 s, Cu, 250 °C, per core)

≈ 5.00 kA

reference

Frequency

50/60 Hz AC

—


Design recommendation: ≈ 128 A in air / ≈ 156 A buried, then apply grouping + ambient correction. Buried rating is higher than air due to better heat dissipation and different reference conditions.


Technical Datasheet — Flame-Retardant (FR) Characteristics
ZR-YJV  0.6/1 kV  4 × 50 mm²  (Cu / XLPE / FR-PVC)
1.  Cable Identification
Code / Item Meaning / Value Standard / Note
ZR Flame Retardant (legacy prefix); under GB/T 19666-2019 defaults to Class C; modern equivalent = ZC GB/T 19666-2019
YJ XLPE — cross-linked polyethylene insulation —
V PVC outer sheath — flame-retardant grade, contains halogen (Cl) GB/T 19666-2019
0.6/1 kV Rated voltage U₀/U = 600/1000 V; maximum Uₘ = 1.2 kV IEC 60502-1
4 × 50 mm² Four cores, nominal copper conductor area 50 mm² per core (all cores equal) —
Construction Unarmoured, non-screened, round multi-core —
Application note Four-core → three-phase AC with neutral (L1+L2+L3+N) or with PE (L1+L2+L3+PE), equal conductor sizes —
2.  Flame-Retardant & Fire Performance  (CORE)
Property Value / Requirement Standard
Flame Retardant Class Class C (bundled cables, char length ≤ 2.5 m) GB/T 19666-2019; GB/T 18380.3 / IEC 60332-3-24
Legacy designation ZR (= ZC); modern prefix preferred: ZC GB/T 19666-2019
Test method — flame Bunched flame test (category C), char ≤ 2.5 m after flame removal GB/T 18380.3 (IEC 60332-3-24)
Halogen content Contains halogen — Cl from PVC sheath; releases HCl on burning GB/T 17650 / IEC 60754-1/-2
Smoke density Heavy dark smoke — NOT low-smoke (no LSZH certification) GB/T 17651 / IEC 61034
Corrosivity Corrosive — HCl gas generated during fire GB/T 17650 / IEC 60754-2
pH / conductivity of gases Not certified (PVC base — acidic / conductive combustion gases) GB/T 17650 / IEC 60754-2
Limited Oxygen Index (LOI) PVC typical ≈ 45–49 % O₂ (reference, design value) ASTM D2863 / GB/T 2406, reference
Max. conductor operating temp. 90 °C (long-term service) GB/T 12706.1-2020
Max. short-circuit temp. (≤5 s) 250 °C IEC 60502-1
Emergency overload temp. 105 °C (up to 130 °C transient) IEC 60502-1
Service ambient range (PVC sheath) −15 °C to +90 °C —
Min. installation ambient temp. 0 °C (pre-heat required below 0 °C) —
Note: ZR = Flame Retardant only — it does NOT imply low-smoke (LSZH) or fire-survival. PVC sheath is halogenated; upgrade to WDZ-YJY for LSZH or NH-ZR-YJV for fire-survival circuits.
3.  Fire Test Summary
Test Requirement ZR-YJV 4×50 Verdict
Bunched flame test (Class C) Char length ≤ 2.5 m PASS (design, Class C)
Single flame test (IEC 60332-1) Self-extinguishing PASS (XLPE/PVC FR)
Smoke density (IEC 61034) Light transmittance ≥ 60 % for LSZH N/A (PVC = heavy smoke)
Halogen content (IEC 60754) ≤ 0.5 % HCl for LSZH N/A (contains Cl)
Acidity / corrosivity (IEC 60754-2) pH ≥ 4.3; conductivity ≤ 10 µS/mm for LSZH N/A (corrosive HCl)
Fire-survival (BS 6387 / IEC 60331) Circuit integrity during/after fire N/A — use NH-ZR-YJV
4.  Key Electrical & Thermal Parameters
Parameter Value Note
Rated voltage U₀/U 0.6 / 1 kV Uₘ = 1.2 kV
Test voltage AC (5 min, routine) 3.5 kV IEC 60502-1
Type-test voltage 4.0 kV IEC 60502-1
DC resistance @ 20 °C (per core) ≤ 0.387 Ω/km GB/T 3956 / IEC 60228, Class 2 max
AC resistance @ 90 °C (est.) ≈ 0.503 Ω/km per core
Current rating — in air (30 °C, single circuit) ≈ 120–135 A (design ≈ 128 A) 4-core
Current rating — direct buried (20 °C, soil 1.0 K·m/W, 0.7 m) ≈ 148–165 A (design ≈ 156 A) 4-core
Short-circuit current (1 s, Cu, 250 °C, per core) ≈ 5.00 kA reference
Frequency 50/60 Hz AC —
Design recommendation: ≈ 128 A in air / ≈ 156 A buried, then apply grouping & ambient temperature correction. Buried rating > air rating due to better heat dissipation & different reference conditions.
5.  Construction & Material Specification
Layer (inside → out) Description / Specification FR Contribution
Conductor (×4) Bare annealed copper, Class 2 stranded, 19×∅1.78 mm, conductor Ø ≈ 9.0 mm None (Cu non-combustible)
Conductor screen Omitted (not required for 0.6/1 kV) —
Insulation (×4) XLPE, colours: brown/black/grey/blue etc., 1.0 mm nominal XLPE — low flame spread
Filler Flame-retardant PP / PE to form round assembly FR additive
Binder Flame-retardant tape over laid-up cores FR barrier
Outer sheath Flame-retardant PVC (ZR grade), 1.8 mm nominal, black Primary FR layer (halogenated)
Armour None —
Metallic screen None —
6.  Dimensional Data
Item Typical Value Remarks
Conductor nominal area (per core) 50 mm² —
Number of cores 4 —
Conductor construction Class 2, 19×∅1.78 mm min. 19 wires
Conductor diameter (approx.) 9.0 mm —
Insulation thickness 1.0 mm 50 mm² class
Diameter over insulated core 11.0 mm 9.0 + 2×1.0
Sheath thickness 1.8 mm multi-core rule, ≥ 1.8 mm
Overall cable diameter 26.0 – 27.5 mm (use 26.8 mm for design) —
Approx. weight 1080 – 1200 kg/km (use ≈ 1140 kg/km) —
Cable shape Round —
7.  Mechanical & Installation Parameters
Parameter Value Note
Minimum bending radius (unarmoured multi-core) ≥ 15 × OD ≈ 402 mm @ Ø26.8 mm —
Max. pulling tension (Cu only) 50 N/mm² × 50 mm² × 4 = 10,000 N total use conductor sock, avoid sheath grip
Direct burial Allowed in non-aggressive soil; for mechanical protection use ZR-YJV22 4×50 —
Conduit ID ≥ 1.5 × OD → ≥ 40 mm (use 50 mm conduit) —



8.  Selection Guide — When FR Matters
Scenario Recommended Cable Reason
Flame-retardant, halogenated acceptable (standard) ZR-YJV 4×50 (this cable) Class C FR, PVC sheath, cost-effective
Low-smoke halogen-free required (LSZH) WDZ-YJY 4×50 LSZH sheath — IEC 61034 / IEC 60754 compliant
Fire-survival circuit (circuit integrity) NH-ZR-YJV 4×50 BS 6387 / IEC 60331 fire-survival grade
Heavy mechanical load / direct burial risk ZR-YJV22 4×50 Steel-tape armoured version
Separate PE and N required 5-core version 4×50 has combined/shared PE-N only
Applicable standards: GB/T 12706.1-2020 (equiv. IEC 60502-1) · GB/T 3956 / IEC 60228 · GB/T 19666-2019 · GB/T 18380.3 · GB/T 17651 / IEC 61034 · GB/T 17650 / IEC 60754.  |  Packing: steel-wooden drum or coil, 100–500 m typical.  |  HS code (China): 8544 4921.
Values are typical / design reference. Always confirm with manufacturer test reports & relevant local regulations before final specification.
  1. Temperature Characteristics
  • Max. conductor operating temp.: 90 °C
  • Max. short-circuit temp. (≤5 s): 250 °C
  • Emergency overload temp.: 105 °C
  • Min. installation ambient temp.: 0 °C (pre-heat below 0 °C)
  • Service ambient range: −15 °C to +90 °C (PVC sheath)
  • Flame retardant class: Class C (ZR per GB/T 19666)
  1. Fire Performance (ZR-YJV)

Property

Value / Requirement

Flame retardant

Class C (bundled, char ≤ 2.5 m)

Halogen content

Contains Cl (PVC), produces HCl

Smoke density

Heavy dark smoke (not low-smoke)

Corrosivity

Corrosive HCl gas

pH / conductivity

Not certified (PVC base)


Cross Section Structure


ZR-YJV 4×50mm² 0.6/1kV Flame Retardant Copper Cable, XLPE Insulation for Building Power Distribution

Product Structure Introduction — ZR-YJV 4×50 mm²
Four-core layered construction description, from conductor to outer sheath · per GB/T 12706.1 & IEC 60502-1 · CU / XLPE / PVC · 0.6/1 kV
1. Cable Overview
ZR-YJV 4×50 is a flame-retarded four-core power cable for 0.6/1 kV AC distribution, of the copper / XLPE / PVC family, designed and tested to GB/T 12706.1 / IEC 60502-1. Conductors comply with GB/T 3956 / IEC 60228, and the flame class follows GB/T 19666 (ZC default). Approx. outside diameter 31.0 mm, weight 2172 kg/km; standard supply on 100 m coils or drums.
With four identical 50 mm² cores, the cable serves three-phase circuits while keeping a full-size neutral for unbalanced or harmonic-bearing loads.
2. Conductor Design
At this section the conductor switches from 7-wire to 10-wire stranding: each core carries ten 2.52 mm annealed copper wires (10/2.52, Class 2), laid to ≈ 8.40 mm diameter. Maximum DC resistance is 0.387 Ω/km at 20 °C. The finer wire division eases bending of the heavier cable and reduces eddy-current loss in AC duty.
3. Dielectric Design
The XLPE insulation wall rises to 1.0 mm in the 50 mm² band, taking each core to ≈ 10.40 mm over insulation. The dielectric handles the routine 3.5 kV AC five-minute proof test, supports 90 °C continuous conductor temperature and 250 °C for five seconds of short-circuit, and shows volume resistivity of at least 1×10¹² Ω·cm.
4. Core Assembly & Jacket
Four insulated cores are twisted around a dry central filler into a round bundle of roughly 25.1 mm, secured with binder tape, then sheathed with 1.8 mm of flame-retarded ST2 PVC to a finished ≈ 31.0 mm. The ZC fire performance is certified through GB/T 18380.12 and GB/T 18380.35; because PVC is halogen-bearing, LSZH projects should specify WDZ-YJY.
5. Field Notes
• Maintain bends of at least 15 × OD.  • Perform the DC 4U0 = 2.4 kV / 15 min site test before switching on.  • Service ambient −20 to +45 °C; warm reels when laying below 0 °C.  • Apply ambient, grouping and burial derating to the quoted ampacity.  • Terminate with lugs sized for the ≈ 8.40 mm core.


ZR-YJV 4×50 mm² — Cable Cross-Section Structure (Schematic)
Four-core construction from conductor to outer sheath · nominal values per GB/T 12706.1 / IEC 60502-1 · not to exact scale






No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductor (Cu) × 4 Annealed copper, Class 2 stranded — 10 × 2.52 mm per core (10/2.52), nominal 50 mm² per core — ≈ 8.40 (Ø per core) Current-carrying element; max DC resistance ≤ 0.387 Ω/km @ 20 °C (per core)
2 Insulation (XLPE) × 4 Cross-linked polyethylene 1 ≈ 10.40 (Ø per core, over insulation) Dielectric barrier; rated 90 °C continuous; withstands 3.5 kV / 5 min
3 Core lay-up Four insulated cores laid up around central non-hygroscopic filler; binder tape — ≈ 25.1 (Ø over lay-up, calc.) Forms a round assembly for sheathing
4 Outer sheath (PVC) Flame-retardant PVC, ST2 type, black 1.8 ≈ 31.0 (Ø overall) Mechanical & moisture protection; flame retardance ZC (ZR) per GB/T 19666












Key Dimensions & Properties
Overall diameter ≈ 31.0 mm Mingda four-core unarmored table

Approx. cable weight ≈ 2172 kg/km Mingda 2172 (Al ≈ 961.1)

Rated voltage 0.6/1 kV AC 50 Hz; max system voltage Um = 1.2 kV

Max conductor temperature 90 / 250 °C Continuous / short-circuit (≤ 5 s)

Min. bending radius (multi-core) ≥ 15 × OD — OD = actual cable diameter

Flame-retardant class ZC (ZR) — GB/T 19666

Schematic — not to exact scale. Nominal values for reference; confirm against factory test certificate.


For low-smoke halogen-free → use WDZ-YJY 4×50; for fire-survival → NH-ZR-YJV 4×50.

  1. Mechanical & Installation Parameters
  • Minimum bending radius (unarmoured multi-core): ≥ 15 × OD → ≈ 402 mm at Ø26.8 mm
  • Max. pulling tension (Cu only): 50 N/mm² × 50 mm² × 4 = 10,000 N total
  • Sheath grip: avoid; use conductor sock
  • Direct burial: allowed in non-aggressive soil; for mechanical protection use ZR-YJV22 4×50
  • Conduit ID: ≥ 1.5 × OD → ≥ 40 mm (use 50 mm conduit)
  • Elevation: no limit for XLPE
  1. Material Specification Summary

Component

Specification

Conductor

Cu annealed, Class 2, 19×1.78 mm, IEC 60228

Insulation

XLPE, 1.0 mm nom., 90 °C

Filler

Flame-retardant PP/PE

Binder

Flame-retardant tape

Sheath

Flame-retardant PVC, 1.8 mm nom. (black)

Armour

None

Screen

None

  1. Scope of Application / Usage Range

ZR-YJV 0.6/1 kV 4×50 mm² is for fixed installation in LV distribution up to 1.2 kV where flame-retardant (ZR = Class C) PVC-sheathed cable is acceptable.


ZR-YJV 4×50mm² 0.6/1kV Flame Retardant Copper Cable, XLPE Insulation for Building Power Distribution


Typical use:

  • Three-phase AC circuits with neutral (L1+L2+L3+N) — primary use of 4-core
  • Three-phase AC circuits with protective earth (L1+L2+L3+PE)
  • Power distribution, motor feeders with neutral, lighting sub-circuits
  • Cable trays, ducts, trenches, shafts in residential / commercial buildings with flame-retardant requirement
  • Fixed wiring in industrial plants, workshops
  • Direct buried routes (non-aggressive soil, low mechanical impact)

Not suitable for:

  • Routes requiring low-smoke halogen-free → use WDZ-YJY 4×50
  • Fire-survival circuits → use NH-ZR-YJV 4×50
  • Heavy mechanical load → use ZR-YJV22 4×50
  • Circuits requiring separate PE and N (use 5-core)
  1. Packing
  • Drum / coil: Steel-wooden drum or coil; 100–500 m typical
  • HS code (China): 8544 4921

ZR-YJV 4×50mm² 0.6/1kV Flame Retardant Copper Cable, XLPE Insulation for Building Power Distribution