logo
Anhui Tongdu International Trade Co., Ltd.
Online Service

Online Service

Contact Person
+86 19056002718
WeChat QR Code
Follow Us
Search Results For:

"1 electrical building wires pvc or lszh low smoke zero halogen"

- 70 Items Found
Quality BTTRZ X50mm2+1x25mm2 Fire Resistant Cable Mineral Emergency Power Copper Sheathed Cable factory

BTTRZ X50mm2+1x25mm2 Fire Resistant Cable Mineral Emergency Power Copper Sheathed Cable

BTTRZ x50mm²+1x25mm² Mineral Insulated Fire Resistant Copper Sheathed Cable for Emergency Power Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire/power cable) T Copper conductor (Tong = copper) T Copper sheath (Tong = copper) R Flexible (Rou = flexible) Z Heavy ...

Quality BTTRZ 0.6/1kV 4x50mm²+1x25mm² Fire-resistant Cable for Industrial Emergency Feeders factory

BTTRZ 0.6/1kV 4x50mm²+1x25mm² Fire-resistant Cable for Industrial Emergency Feeders

BTTRZ 0.6/1kV 4x50mm²+1x25mm² Fire-resistant Cable for Industrial Emergency Feeders Cable Designation & Meaning Code Meaning B Fixed wiring T Copper conductor T Copper sheath R Flexible Z Heavy duty 4×50 mm² Four cores of 50 mm² copper conductor (phases) +1×25 mm² One core of 25 mm² copper conductor ...

Quality 4x70mm2+1x35mm2 Fire Resistant Cable 1KV 1.2KV Bare Copper Mineral Insulated Cable factory

4x70mm2+1x35mm2 Fire Resistant Cable 1KV 1.2KV Bare Copper Mineral Insulated Cable

Heavy Duty Fire Cable BTTRZ 4x70mm²+1x35mm² Mineral Insulated 0.6/1kV Cable Designation & Meaning Code Meaning BTTRZ Flexible mineral-insulated copper-sheathed fire-resistant cable 4×70 mm² Four cores of 70 mm² copper conductor (3 phase + 1 neutral) +1×35 mm² One core of 35 mm² copper conductor ...

Quality 4x185mm2+1x195mm2 Fire Resistant Cable 0.6KV 1KV Mineral Insulated Copper Cable factory

4x185mm2+1x195mm2 Fire Resistant Cable 0.6KV 1KV Mineral Insulated Copper Cable

Super Fire Cable BTTRZ 4x185mm²+1x95mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ Flexible mineral-insulated copper-sheathed fire-resistant cable 4×185 mm² Four cores of 185 mm² copper conductor (3 phase + 1 neutral) +1×95 mm² One core of 95 mm² copper ...

Quality 4+1 Core Fire Resistant Cable 120mm2+1x70mm2 BTTRZ Fire Substation Cable factory

4+1 Core Fire Resistant Cable 120mm2+1x70mm2 BTTRZ Fire Substation Cable

Fire Substation Cable 4+1 Core 120mm²+1x70mm² BTTRZ Fire Resistant Mineral Insulated Cable Designation & Meaning Code Meaning BTTRZ Flexible mineral-insulated copper-sheathed fire-resistant cable 4×120 mm² Four cores of 120 mm² copper conductor (3 phase + 1 neutral) +1×70 mm² One core of 70 mm² ...

Quality Fire Resistant Cable BTTRZ 4x50mm²+1x25mm² Mineral Insulated 0.6/1kV factory

Fire Resistant Cable BTTRZ 4x50mm²+1x25mm² Mineral Insulated 0.6/1kV

Fire Resistant Cable BTTRZ 4x50mm²+1x25mm² Mineral Insulated 0.6/1kV Technical Datasheet — BTTRZ 0.6/1 kV 4×50 mm² + 1×25 mm² Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = ...

Quality 4+1 Core BTTRZ 4x16mm²+1x10mm² Mineral Insulated Fire Resistant Cable 0.6/1kV factory

4+1 Core BTTRZ 4x16mm²+1x10mm² Mineral Insulated Fire Resistant Cable 0.6/1kV

4+1 Core BTTRZ 4x16mm²+1x10mm² Mineral Insulated Fire Resistant Cable 0.6/1kV Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV ...

Quality 25 Mm2 Fire Resistant Cable 4x25mm2+1x16mm2 Mineral Insulated Copper factory

25 Mm2 Fire Resistant Cable 4x25mm2+1x16mm2 Mineral Insulated Copper

0.6/1kV Mineral Insulated Cable BTTRZ 4x25mm²+1x16mm² Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV Rated ...

Quality Hospital Critical Fire Proof Cable BTTRZ 4x35mm²+1x16mm² Mineral Mi Heating Cable factory

Hospital Critical Fire Proof Cable BTTRZ 4x35mm²+1x16mm² Mineral Mi Heating Cable

Hospital Critical Fire Proof Cable BTTRZ 4x35mm²+1x16mm² Mineral Mi Heating Cable Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...

Prev 4 5 6 7 8 Next