logo
Anhui Tongdu International Trade Co., Ltd.
Online Service

Online Service

Contact Person
+86 19056002718
WeChat QR Code
Follow Us

Flame Retardant 5 Cores Cable ZR-YJV 35mm2 Xlpe Copper Armoured For Main Power Feeds

Flame Retardant 5 Cores Cable ZR-YJV 35mm2 Xlpe Copper Armoured For Main Power Feeds

Basic Properties

country of origin
China
brand name
TD
certificate
CE/ISO/CCC
product model
ZR-YJV 5*35mm²

Trading Properties

moq
1 Meter
payment method
L/C,T/T
supply capacity
10000 meters per month

Product Summary

Flame Retardant ZR-YJV 5 Core 35mm² Copper Cable for Building Main Power Feeds Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 5×35 mm² Five equal cores of 35 mm² copper conductor Construction: Five ...

Product Details

Highlight:

Flame Retardant 5 Core Cable

,

5 Core Cable IEC 60228

,

Power Feeds xlpe copper armoured cable

Conductor (×5):
Bare Annealed Copper, Class 2 Stranded, 7×∅2.52 Mm (also 19×∅1.53 Mm Compact), Conductor Ø ≈ 7.6–8.0 Mm Depending On Compaction
Conductor nominal area (per core):
35 Mm²
Number of cores:
5
Conductor construction:
Class 2, 7×∅2.52 Mm,IEC 60228 / GB/T 3956, Min. 7 Wires
Conductor diameter (approx.):
7.6–8.0 Mm
Insulation (×5):
XLPE
Insulation thickness:
0.9 Mm (35 Mm² Class)
Diameter over insulated core:
9.4–9.8 Mm,conductor + 2×0.9
Filler / binder:
FR PP Filler + FR Tape
Outer sheath:
Flame-retardant PVC (ZR Grade)
Sheath thickness:
1.5 Mm (GB/T 12706 Multi-core 5-core 16–35 Mm² Range)
Overall cable diameter:
19.5 – 23.5 Mm
Design outer diameter:
≈ 21.0 Mm
Approx. weight:
680 – 860 Kg/km
Design weight:
≈ 750 Kg/km
Cable shape:
Round

Product Description

Flame Retardant ZR-YJV 5 Core 35mm² Copper Cable for Building Main Power Feeds

Cable Designation & Meaning

Code

Meaning

ZC

Flame retardant Class C 

YJ

Cross-linked polyethylene (XLPE) insulation 

V

Polyvinyl chloride (PVC) sheath

5×35 mm²

Five equal cores of 35 mm² copper conductor


Construction: Five 35 mm² copper conductors (3 phase + 1 neutral + 1 earth), XLPE insulation, PVC outer sheath. No metallic screen/armour as standard (can be added on request).

Applicable Standards

  • GB/T 12706.1-2020 / IEC 60502-1 — Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1.2 kV) up to 30 kV (Um = 36 kV) — Part 1: Cables for rated voltages of 1 kV (Um = 1.2 kV) and 3 kV (Um = 3.6 kV)
  • GB/T 19666-2019 — Flame retardant and fire resistant wires and cables 
  • GB/T 18380.12 / IEC 60332-1-2 — Flame propagation test for a single vertical insulated wire
  • GB/T 3956-2008 / IEC 60228 — Conductors of insulated cables
  • GB/T 2951-2008 / IEC 60811 — Common test methods for insulating and sheathing materials


Flame Retardant 5 Cores Cable ZR-YJV 35mm2 Xlpe Copper Armoured For Main Power Feeds

ZC-YJV 5×35 mm² — LV Flame-Retardant Five-Core TN-S Medium Feeder Cable — Specification

1. Overview & Ratings. ZC-YJV 5×35 is a five-core LV medium feeder rated 0.6/1 kV (Um 1.2), 90 °C working, ZC class C PVC sheath: five equal 35 mm² compacted copper cores (L1/L2/L3 plus neutral N and separate protective PE), dry-cured XLPE, unarmored. OD ≈ 23 mm, ≈ 2100 kg/km (est.), ≈ 110 A per core free air at 30 °C (est.). Scope: workshop equipment feeders, power socket groups and HVAC unit supplies — not 950°C fire duty.


2. Construction Stack (Inner → Outer, expanded).


Layer / Feature Build Function
Phase cores L1/L2/L3 3×35 compacted Cu, Class 2, ≈12 strands Phases; R ≤0.524
Neutral N 1×35 compacted Cu, equal Separate return; distinct from PE
Protective PE 1×35 compacted Cu, dedicated TN-S safety earth
Strand compaction Concentric layers rolled compact per core Compact round bundle, clean lugs
XLPE insulation Dry-cured PE, ≈1.4 mm on each core Uniform 90°C dielectric
Five-core laying Equal cores into round bundle Compact round cable
PVC ZC sheath Class C, ≈1.8 mm overall Self-extinguishes, prints clear


3. Electrical Characteristics. All five cores R ≤ 0.524 Ω/km @20 °C. Test 3.5 kV AC / 5 min; ≈ 110 A per core (est., air 30 °C); short-circuit ≈ 4.6 kA / 1 s (est.); 50/60 Hz; unscreened; separate N and PE; low-loss XLPE; high stable insulation resistance.

Insulation & Sheath Data

Property

Value

Insulation material

XLPE (cross-linked polyethylene)

Outer sheath material

PVC (ST₂)

Long-term service temp.

90 °C (continuous)

Max. conductor temp. (normal)

90 °C

Short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Test voltage AC (5 min)

3.5 kV

Dielectric strength

≥ 20 kV/mm

Volume resistivity @20 °C

≥ 1×10¹⁴ Ω·cm

Shield

None as standard (can be added)

Electrical Parameters

Parameter

Value

Note

Rated voltage U₀/U

0.6 / 1 kV

GB/T 12706.1 / IEC 60502-1

Max. system voltage

1.2 kV AC

—

Test voltage AC (5 min)

3.5 kV

Routine test

DC resistance @20 °C

≤ 0.524 Ω/km per core

GB/T 3956 Class 2 Cu max (35 mm²)

AC resistance @90 °C (est.)

≈ 0.672 Ω/km per core

—

Current rating in air (30 °C)

3-phase: 115 A​

5×35, touching, in free air

Current rating in tray (30 °C)

3-phase: 128 A​

5×35, spaced 2×OD

Current rating buried in ground (20 °C, thermal resistivity 1.2 K·m/W)

3-phase: 120 A​

direct buried

Current rating in conduit (30 °C)

3-phase: 105 A​

—

Short-circuit current (1 s, Cu, 250 °C)

≈ 3.85 kA (3,850 A) per core

—

Capacitance (core-to-sheath, approx.)

≈ 0.19 µF/km

XLPE

Inductive reactance (approx.)

≈ 0.08 Ω/km

at 50 Hz

Frequency

50/60 Hz AC

—


Reference values: 5×35 at 115 A three-phase, 400 V → max load ≈ 69 kW​ (cos φ = 0.8). Suitable for light-to-medium three-phase distribution with full neutral and earth (TN-S), small-to-medium industrial panels, and building sub-branch circuits.


4. Thermal & Flame. 90 °C continuous, 250 °C short-time; ZC class C self-extinguishing — flame retardancy, not 950°C integrity; withstands feeder cycling; indoor preferred, UV jacket optional for exposed runs.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

90 °C (continuous)

Max. short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Min. installation ambient temp.

0 °C (below 0 °C requires preheating)

Service ambient range

−20 °C to +90 °C

Flexing temp. range

0 °C to +90 °C

Fire Performance (ZC-YJV — Flame Retardant C)

Property

Value / Requirement

Flame retardant

GB/T 18380.12 / IEC 60332-1-2​ (single cable, self-extinguishing)

Flame retardant class

Class C​ (ZC) per GB/T 19666

Halogen content

Contains halogen (PVC sheath)

Smoke density

Not low-smoke (PVC)

Corrosivity

Corrosive (PVC)

Toxicity

Toxic fumes when burned (PVC)

EMI shielding

None (no metallic screen/armour)


5. Installation Practice & Handling. Hydraulic crimp 35 mm² lugs on all five cores, glands to ≈23 mm OD, torque per table; bend ≥ 15×OD ≈ 345 mm; keep N and PE distinct; apply tray derating; verify continuity of all cores, phase sequence, N/PE separation and insulation before energizing.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 15 × OD → ≈ 338 mm at Ø22.5 mm

five-core unarmoured

Max. pulling tension

525 N per core (35 mm² × 15 N/mm²)

Cu conductor limit

Direct burial

Suitable (with sand bedding)

—

Surface mounting

Cable tray, ladder, cleats

—

Conduit ID

≥ 40 mm

—

Fixing

cleats, cable ties

—

Impact resistance

Moderate

—

Water resistance

Good (PVC sheath)

—

UV resistance

Fair (PVC degrades outdoors, use UV-resistant PVC or conduit)

—

Flex life

Good (Class 2 stranded)

fixed installation

Termination note

Standard compression lugs or mechanical connectors

—


6. Typical Service Applications. Workshop machine feeders, power socket groups, HVAC unit supplies, and balanced three-phase TN-S distribution boards.


Flame Retardant 5 Cores Cable ZR-YJV 35mm2 Xlpe Copper Armoured For Main Power Feeds


7. Testing & QA Regime (16 items). Routine: DC resistance all cores, 3.5 kV withstand, insulation resistance, continuity, insulation thickness, sheath thickness, dimensional check, strand construction, core color coding, N/PE separation check, print legibility, mass, packing inspection. Type: ZC flame test, short-circuit rating, sheath mechanical.


Cable Parameters


ZR-YJV 5×35 mm² — Flame-Retardant Five-Core Power Cable (0.6/1 kV) · Product Parameters
CU / XLPE / PVC · 5 × 35 mm² · GB/T 12706.1, IEC 60502-1, GB/T 3956, GB/T 19666 · nominal values for reference
Code Parameter Value Unit Remarks
01 · Identification
Std: GB/T 12706.1 / IEC 60502-1; fire GB/T 19666; Um = 1.2 kV; 50 Hz
1-A Product name Flame-retardant copper-conductor XLPE-insulated PVC-sheathed power cable (five-core) — ZR-YJV; halogen-containing flame-retardant
1-B Model ZR-YJV 5×35 — 5 cores × 35 mm²; CU / XLPE / PVC
1-C Design standards GB/T 12706.1; IEC 60502-1 — Conductor GB/T 3956
1-D Rated voltage U0/U 0.6/1 kV Um = 1.2 kV; AC 50 Hz
1-E Core arrangement 5 cores (L1/L2/L3/N/PE) — Three phases + neutral + earth
1-F Nominal cross-section 35 mm² Per core, GB/T 3956
02 · Conductor
Std: GB/T 3956 / IEC 60228 Class 2 — 35 mm² = 7 wires (round)
2-A Material Plain annealed copper — High conductivity
2-B Class Class 2 (stranded) — GB/T 3956 / IEC 60228
2-C Stranding (per core) 7 × 2.52 mm (7/2.52) — 1+6 concentric rings
2-D Conductor diameter ≈ 7.6 mm Per core (7 × 2.52)
2-E Max. DC resistance @ 20 °C 0.524 Ω/km GB/T 3956 Class 2 Cu
03 · Insulation
Std: Mingda five-core unarmored table — 1.2 mm wall at 35 mm²
3-A Material Cross-linked polyethylene (XLPE) — Thermally cross-linked
3-B Nominal thickness 1.2 mm Mingda five-core table
3-C Diameter over insulation ≈ 10.0 mm Per core (calculated)
04 · Assembly
Std: pentagonal ring lay-up; filler takes the residual gap
4-A Core lay-up Five cores in a pentagonal ring + dry filler + binder tape — Round bundle
4-B Diameter over lay-up ≈ 26.1 mm Calculated (Ø 29.7 − 2 × 1.8)
05 · Sheath
Std: Mingda five-core unarmored table (Ø 29.7; 2004 / 887.1 kg/km)
5-A Material Flame-retardant PVC, ST2 — Black (or as ordered)
5-B Nominal thickness 1.8 mm Mingda five-core table
5-C Overall diameter ≈ 29.7 mm Mingda five-core unarmored
5-D Approx. cable weight ≈ 2004 kg/km Mingda 2004 (YJLV ≈ 887.1)
06 · Electrical
Std: Mingda five-core unarmored table (soil 155 / air 125 A Cu @ 25 °C)
6-A DC conductor resistance 0.524 Ω/km GB/T 3956 @ 20 °C, per core
6-B Routine voltage test 3.5 kV / 5 min — No breakdown; 50 Hz AC
6-C Insulation resistance ≥ 36.7 MΩ·km Finished cable @ 20 °C
6-D XLPE volume resistivity ≥ 1 × 10¹² Ω·cm Material level
6-E Capacitance (approx.) ≤ 0.45 μF/km Per core
6-F Ampacity — buried @ 25 °C (5 cores) ≈ 155 A Mingda basis (Cu)
6-G Ampacity — air @ 25 °C (5 cores) ≈ 125 A Mingda basis (Cu)
07 · Thermal
Std: XLPE class per GB/T 12706.1 / IEC 60502-1
7-A Continuous conductor temperature 90 °C XLPE class
7-B Short-circuit temperature (≤ 5 s) 250 °C GB/T 12706.1 / IEC 60502-1
7-C Ambient service range -20 to +45 °C Per datasheet family
7-D Min. laying temperature 0 °C Pre-heat below 0 °C
08 · Fire (ZR)
Std: GB/T 19666; GB/T 18380.12; GB/T 18380.35 (20 min, ≥ 1.5 L/m)
8-A Flame-retardant class ZC by default ("ZR") — Halogen-containing PVC
8-B Single-cable flame test Pass — GB/T 18380.12
8-C Bunched flame test — class C Char ≤ 2.5 m — GB/T 18380.35
8-D Halogen content Halogen-containing — LSZH needs WDZ-YJY
09 · Installation
Std: Q/GDW 13244.1-2018 for site test
9-A Min. bending radius (multi-core) ≥ 15 × OD — GB 50168 practice
9-B Laying methods Conduit, tray, trench, duct, trunking — Mechanical protection where buried
9-C Site test after installation DC 4U0 = 2.4 kV / 15 min — Q/GDW 13244.1-2018
10 · Packing
Std: custom lengths available; GB/T 6995 / project spec
10-A Standard delivery length 100 m per coil/drum — Custom lengths available
10-B Marking Model, voltage, maker, year, length marks — GB/T 6995 / project spec


Cable Test Parameters


ZR-YJV 5×35 mm² — Test / Verification Parameters (per GB/T 12706.1 & IEC 60502-1)
Stage Test Item Method / Standard Acceptance Criterion Notes
Routine Conductor DC resistance GB/T 3956 (IEC 60228) ≤ 0.524 Ω/km @ 20 °C (per core) Every production length
Routine Power-frequency withstand voltage GB/T 12706.1 / IEC 60502-1 3.5 kV AC / 5 min, no breakdown Conductor-to-earth/water
Routine Construction check GB/T 2951 Ins. ≥ 1.2 mm; sheath ≥ 1.8 mm; OD within tolerance Thickness & diameter
Sample Hot set test — XLPE GB/T 12706.1 §16.3.13 / GB/T 2951.11 200 ± 3 °C, 15 min, 0.2 MPa: load elongation ≤ 175 %; permanent ≤ 15 % Cross-linking degree
Sample Conductor construction & diameter GB/T 3956 Class 2; 7 × 2.52 mm; Ø ≈ 7.6 mm Per batch
Type Single-cable flame test GB/T 18380.12 No flame spread to top reference ZR property
Type Bunched flame test — class C GB/T 18380.35 Char ≤ 2.5 m; 20 min; ≥ 1.5 L/m ZC class
Type Bending test GB/T 12706.1 No damage on specified mandrel Multi-core rule
Post-install DC withstand test Q/GDW 13244.1-2018 2.4 kV DC / 15 min, no breakdown New installations
Optional Insulation resistance @ 20 °C Factory method ≥ 36.7 MΩ·km Not routine in GB/T 12706.1
Optional XLPE volume resistivity Material test ≥ 1 × 10¹² Ω·cm Material reference


Cable Cross Section Structure

Flame Retardant 5 Cores Cable ZR-YJV 35mm2 Xlpe Copper Armoured For Main Power Feeds


ZR-YJV 5×35 mm² — Cable Cross-Section Structure (Schematic)
Five-core construction from conductor to outer sheath · nominal values per GB/T 12706.1 / IEC 60502-1 · not to exact scale
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductor (Cu) × 5 Annealed copper, Class 2 stranded — 7 × 2.52 mm per core (7/2.52, 1+6), nominal 35 mm² per core — ≈ 7.6 (Ø per core) Current-carrying element; max DC resistance ≤ 0.524 Ω/km @ 20 °C (per core)
2 Insulation (XLPE) × 5 Cross-linked polyethylene 1.2 ≈ 10.0 (Ø per core, over insulation) Dielectric barrier; rated 90 °C continuous; withstands 3.5 kV / 5 min
3 Core lay-up Five insulated cores laid up in a pentagonal ring around dry filler; binder tape — ≈ 26.1 (Ø over lay-up, calc.) Round assembly; the 5th core is the PE (earthing) core
4 Outer sheath (PVC) Flame-retardant PVC, ST2 type, black 1.8 ≈ 29.7 (Ø overall, Mingda five-core) Mechanical & moisture protection; flame retardance ZC (ZR) per GB/T 19666
Key Dimensions & Properties
Overall diameter ≈ 29.7 mm Mingda five-core unarmored table

Approx. cable weight ≈ 2004 kg/km Mingda 2004 (Al ≈ 887.1)

Rated voltage 0.6/1 kV AC 50 Hz; max system voltage Um = 1.2 kV

Max conductor temperature 90 / 250 °C Continuous / short-circuit (≤ 5 s)

Min. bending radius (multi-core) ≥ 15 × OD — OD = actual cable diameter

Flame-retardant class ZC (ZR) — GB/T 19666

Schematic — not to exact scale. Nominal values for reference; confirm against factory test certificate.


Product Structure Introduction


Product Structure Introduction — ZR-YJV 5×35 mm² 
Five-core layered construction description, from conductor to outer sheath · per GB/T 12706.1 & IEC 60502-1 · CU / XLPE / PVC · 0.6/1 kV
1. Overview & Ratings
ZR-YJV 5×35 is the fourth size of the flame-retarding five-core family: five 35 mm² copper conductors, XLPE insulation and one ST2 PVC jacket, rated 0.6/1 kV. Production and testing follow GB/T 12706.1 / IEC 60502-1, stranding follows GB/T 3956, and the ZR (ZC) fire class of GB/T 19666 is standard. Finished diameter ≈ 29.7 mm (Mingda five-core row), weight ≈ 2004 kg/km; 100 m coils or drums.
Five cores loaded, the cable is rated ≈ 125 A in air at 25 °C on the Mingda basis — sized for main distribution feeders, motor circuits and installations where a separate PE core is required.
2. Copper Stranded Conductor
Each 35 mm² core strands seven 2.52 mm annealed wires (7/2.52) in the 1+6 pack — the Class 2 pack for this section — to ≈ 7.6 mm Ø. DC resistance is capped at 0.524 Ω/km at 20 °C; the tight 1+6 arrangement yields a clean circular profile for the 1.2 mm insulation wall and compact terminations.
3. XLPE Dielectric Layer
XLPE is extruded at 1.2 mm — the wall Mingda's five-core table assigns to 35 mm², holding the same 1.2 mm as the 25 mm² five-core size — giving ≈ 10.0 mm per core over the insulation. The dielectric is rated 90 °C continuously and 250 °C for five seconds, holds volume resistivity ≥ 1×10¹² Ω·cm and passes the 3.5 kV AC five-minute routine proof.
4. Cabling & PVC Sheath
Five insulated cores are cabled in a pentagonal ring with dry filler and binder tape into a ≈ 26.1 mm bundle, then sheathed in 1.8 mm of flame-retarded ST2 PVC to the published 29.7 mm finish. The jacket delivers ZC behaviour via GB/T 18380.12 and GB/T 18380.35; since PVC contains halogen, low-smoke orders move to WDZ-YJY.
5. Field Handling & Usage
• Respect the 15 × OD bending floor.  • Apply the DC 4U0 = 2.4 kV / 15 min site test before first energisation.  • Service ambient −20 to +45 °C; warm drums below 0 °C before pulling.  • Derate the 125 A (air) / 155 A (buried) reference for ambient, grouping and soil.  • Use lugs and glands sized for the 7.6 mm core and 29.7 mm sheath.


8. Factory Advantages.

  • Dedicated TN-S safety — separate N and PE cores for compliant earthing.
  • Stable XLPE cure — even cross-linking keeps the 90°C dielectric consistent.
  • Dosed ZC compound — self-extinguishing jacket protects workshop feeders and distribution rooms.
  • Length-on-demand — cut to exact feeder meter with sealed ends.
  • Uniform resistance log — all five equal cores R recorded to lot.
  • Continuous print line — type, size, ZC, voltage and length readable along tray runs.
  • Color-coded cores — phase, neutral and PE distinguished at terminals.
  • Sturdy rated drum — medium section wound on a structurally rated drum.
  • Certified QA pack — routine + type test record shipped per batch.

Flame Retardant 5 Cores Cable ZR-YJV 35mm2 Xlpe Copper Armoured For Main Power Feeds


10. Procurement Specification. State "ZC-YJV 5×35", length, class C and the TN-S requirement; request resistance log and 16-item QA record. Est. values confirmed against the factory certificate.


11. Cable Industry FAQ.

  • Q1: How does 5×35 differ from 4×70? A five-wire TN-S feeder rather than a four-core power cable: five 35 mm² equal cores vs four 70; R 0.524 vs 0.268 Ω/km, current ≈110 vs 175 A; aimed at equipment feeders and socket groups with a dedicated PE rather than a heavy four-wire branch.
  • Q2: Why a separate PE core? TN-S keeps neutral and protective earth distinct; required where safety earth must remain separate from the neutral conductor.
  • Q3: Is ZC fire-resistant? No. Class C self-extinguishes; it does not hold live at 950°C/180min.
  • Q4: DC resistance? ≤0.524 Ω/km at 20°C on every 35 mm² core.
  • Q5: Screen or armor? Unscreened standard; add braid near VFD EMI; steel-tape armor for buried ducts.
  • Q6: Current per core? ≈110 A (est.) free air 30°C; derate in crowded trays.
  • Q7: Bending? ≈345 mm (15×OD); use large sheaves on this feeder section.
  • Q8: Connectors? 35 mm² lugs on all five cores; gland to ≈23 mm OD.
  • Q9: Indoor or outdoor? Indoor preferred; specify UV-stabilized jacket for exposed runs.
  • Q10: Packing? Rated wooden drum with moisture-sealed ends.
  • Q11: What proof ships? Resistance log + 16-test record; est. values confirmed against certificate.