RVV 4 Core Flexible Control Cable 4x0.75mm2 Stranded Copper Conductor PVC Insulated
Basic Properties
Trading Properties
Product Summary
Product Details
RVV 4 Core Flexible Cable
,4 Core Flexible Cable 4x0.75mm2
,PVC Insulated 4 core control cable
Product Description
RVV-4*0.75mm² Premium RVV 4 Core Control Cable Stranded Copper Conductor PVC Insulated,Outer Sheathed
Cable Designation & Meaning
|
Code |
Meaning |
|---|---|
|
R |
Flexible conductor |
|
V |
PVC insulation |
|
V |
PVC sheath |
|
4×0.75 mm² |
Four cores of 0.75 mm² copper conductor |
Construction: Four 0.75 mm² fine-stranded copper conductors, PVC insulation on each core, PVC outer sheath over twisted cores with filler. No metallic screen/armour as standard (can be added on request as RVVP).
Applicable Standards
- GB/T 5023.5-2008 / IEC 60227-5 — Polyvinyl chloride insulated flexible cables (cords) — Part 5: Flexible cables
- GB/T 3956-2008 / IEC 60228 — Conductors of insulated cables (Class 5 flexible)
- GB/T 18380.12 / IEC 60332-1-2 — Flame propagation test for a single vertical insulated wire
- GB/T 2951-2008 / IEC 60811 — Common test methods for insulating and sheathing materials

RVV 4×0.75 mm² — Flexible PVC Insulated PVC Sheathed Multi-Core Control Cord — Specification
1. Overview & Ratings. RVV 4×0.75 is a flexible four-core control cord rated 300/500 V, 70 °C working: four 0.75 mm² fine-strand soft copper cores (Class 5/6) with PVC insulation inside a flexible round PVC sheath. OD ≈ 8.5 mm, ≈ 95 kg/km (est.), ≈ 8 A per core in a four-core bundle at 30 °C (est.). Scope: multi-core control circuits, instrument signal, sensor wiring and relay logic — not a 0.6/1 kV XLPE power feeder.
2. Construction Stack (Inner → Outer, expanded).
| Layer / Feature | Build | Function |
|---|---|---|
| Conductors 1–4 | 4×0.75 soft Cu, Class 5/6, ≈24/0.20 strands | R ≤24.5 Ω/km; flexible |
| Fine-strand stranding | Many fine strands bunched & twisted | Repeated-bend flexibility |
| PVC insulation | Extruded, ≈0.6 mm, 70°C grade | Light 300/500 V dielectric |
| Four-core cabling | Insulated cores cabled 2×2 | Compact round cord |
| Flexible PVC sheath | ≈0.9 mm overall | Binds cores, abrasion jacket |
| Optional screen | Braid/foil (RVVP variant) | EMI signal immunity |
3. Electrical Characteristics. R ≤ 24.5 Ω/km @20 °C. Test 2.0 kV AC / 5 min; ≈ 8 A per core in a bundle (est., air 30 °C); 300/500 V; 50/60 Hz; unscreened as standard, RVVP screened variant available.
Insulation & Sheath Data
|
Property |
Value |
|---|---|
|
Insulation material |
PVC (Type TI2) |
|
Outer sheath material |
PVC (Type ST5) |
|
Long-term service temp. |
70 °C (continuous) |
|
Max. conductor temp. (normal) |
70 °C |
|
Short-circuit temp. (≤5 s) |
160 °C |
|
Emergency overload temp. |
100 °C (≤1 h) |
|
Test voltage AC (5 min) |
2.0 kV |
|
Dielectric strength |
≥ 20 kV/mm |
|
Volume resistivity @20 °C |
≥ 1×10¹³ Ω·cm |
|
Shield |
None as standard (RVVP available) |
Electrical Parameters
|
Parameter |
Value |
Note |
|---|---|---|
|
Rated voltage U₀/U |
300 / 500 V |
GB/T 5023.5 / IEC 60227-5 |
|
Max. system voltage |
500 V AC / 700 V DC |
— |
|
Test voltage AC (5 min) |
2.0 kV |
Routine test |
|
DC resistance @20 °C |
≤ 26.0 Ω/km per core |
GB/T 3956 Class 5 Cu max (0.75 mm²) |
|
AC resistance @70 °C (est.) |
≈ 32.0 Ω/km per core |
— |
|
Current rating in air (30 °C) |
Three-phase AC: 13 A (per phase core, 3×L + PE) |
4×0.75, touching, in free air |
|
Current rating in tray (30 °C) |
Three-phase AC: 15 A (per phase core) |
4×0.75, spaced |
|
Current rating in conduit (30 °C) |
Three-phase AC: 10 A (per phase core) |
— |
|
Single-phase current capacity |
Single-phase AC: 13 A (L+N, with 2 cores spare) |
— |
|
DC current capacity |
13 A per core |
— |
|
Short-circuit current (1 s, Cu, 160 °C) |
≈ 82 A per core |
— |
|
Capacitance (core-to-core, approx.) |
≈ 0.09 µF/km |
PVC |
|
Inductive reactance (approx.) |
≈ 0.11 Ω/km |
at 50 Hz |
|
Frequency |
50/60 Hz AC |
— |
Reference values: RVV 4×0.75 at 13 A three-phase, 400 V → max load ≈ 9.0 kW (cos φ = 1.0). As single-phase at 13 A, 230 V → max load ≈ 3.0 kW (cos φ = 1.0). Suitable for three-phase low-current control with earth, multi-core signal wiring, sensor arrays, and instrumentation.
4. Thermal & Flame. 70 °C continuous; standard PVC — specify flame-retardant grade where wiring rules require; indoor control use preferred, not a fire-rated circuit.
Temperature Characteristics
|
Property |
Value |
|---|---|
|
Max. conductor operating temp. |
70 °C (continuous) |
|
Max. short-circuit temp. (≤5 s) |
160 °C |
|
Emergency overload temp. |
100 °C (≤1 h) |
|
Min. installation ambient temp. |
−15 °C |
|
Service ambient range |
−15 °C to +70 °C |
|
Flexing temp. range |
−5 °C to +70 °C |
Fire Performance (RVV — Standard, Non-Flame-Retardant)
|
Property |
Value / Requirement |
|---|---|
|
Flame retardant |
GB/T 18380.12 / IEC 60332-1-2 (single cable, self-extinguishing) |
|
Flame retardant class |
None as standard (use ZC-RVV for Class C) |
|
Halogen content |
Contains halogen (PVC) |
|
Smoke density |
Not low-smoke |
|
Corrosivity |
Corrosive (PVC) |
|
Toxicity |
Toxic fumes when burned |
|
EMI shielding |
None (use RVVP for shielded version) |
5. Installation Practice & Handling. Crimp cord-end ferrules or pins on the fine strands before screw terminals; bend ≥ 6×OD ≈ 51 mm; avoid sharp edges and kinking; verify continuity of all four cores and insulation after dressing.
Mechanical & Installation Parameters
|
Parameter |
Value |
Remarks |
|---|---|---|
|
Minimum bending radius |
≥ 6 × OD → ≈ 49 mm at Ø8.2 mm |
flexible cable |
|
Max. pulling tension |
11.25 N per core (0.75 mm² × 15 N/mm²) |
Cu conductor limit |
|
Direct burial |
Not recommended (use buried conduit) |
— |
|
Surface mounting |
Cable tray, conduit, trunking, cable clips |
— |
|
Conduit ID |
≥ 20 mm |
— |
|
Fixing |
cable ties, clips |
— |
|
Impact resistance |
Low (light-duty) |
— |
|
Water resistance |
Limited (PVC sheath) |
— |
|
UV resistance |
Poor (PVC degrades outdoors, use UV-resistant or conduit) |
— |
|
Flex life |
Excellent (Class 5 fine-stranded) |
flexible / portable |
|
Termination note |
Screw terminals, compression lugs, or direct crimp (ferrule recommended) |
— |
6. Typical Service Applications. Multi-core control circuits, instrument signal, sensor wiring, relay logic and 4-wire device connections.

7. Testing & QA Regime (16 items). Routine: DC resistance, 2.0 kV withstand, insulation resistance, continuity, conductor construction, sheath/insulation thickness, dimensional check, core color coding, print legibility, mass, appearance, packing. Type: flame (if grade ordered), flexibility/bending, sheath tensile/elongation.
Cable Parameters
| RVV 4×0.75 mm² — Full Parameter Sheet | ||||
| Copper-core PVC-insulated PVC-sheathed flexible cord · 300/500 V · GB/T 5023.5 / IEC 60227-5 (60227 IEC 52) · finished Ø ≈ 7.6 mm · ≈ 105 kg/km — cross-referenced industry sample data | ||||
| Section | Parameter | Value | Unit | Remarks / Standard |
| 01 · Identification | ||||
| Cable type | RVV | — | Copper conductor, PVC insulation, PVC sheath, flexible round cord (60227 IEC 52) | |
| Rated voltage (U0/U) | 300/500 | V | AC 50 Hz; maximum system voltage Um = 500 V | |
| Number of cores | 4 | — | Four-core round flexible cord (3P+N) | |
| Nominal cross-sectional area | 0.75 × 4 | mm² | Per conductor | |
| Conductor material | Annealed copper (Cu) | — | Class 5 flexible stranded per GB/T 3956 / IEC 60228 | |
| Insulation material | PVC, PVC/C (TI1) compound | — | 70 °C rated | |
| Sheath material | PVC, PVC/ST5 compound | — | Black or custom colour | |
| Standard reference | GB/T 5023.5 / IEC 60227-5 | — | 60227 IEC 52 RVV flexible cords | |
| 02 · Conductor | ||||
| Stranding (per core) | 24 × 0.20 mm | — | Class 5 flexible lay-up | |
| Conductor diameter | ≈ 1.1 | mm | Strand-lay diameter (est.) | |
| DC resistance @ 20 °C | ≤ 26.0 | Ω/km | Maximum per GB/T 3956 Class 5 | |
| DC resistance @ 70 °C | ≈ 33.0 | Ω/km | Temperature-corrected (est.) | |
| Copper mass (all cores) | ≈ 26.7 | kg/km | 4 × 0.75 × 8.89 g/cm³ | |
| Conductor flexibility | Class 5 (flexible) | — | Suitable for repeated bending / appliance leads | |
| 03 · Insulation | ||||
| Insulation thickness (per core) | 0.6 | mm | GB/T 5023.5 specified for 0.75 mm² | |
| Core Ø over insulation | ≈ 2.3 | mm | 1.1 + 2 × 0.6 | |
| Insulation material | PVC, PVC/C (TI1) | — | Thermoplastic, 70 °C rated | |
| Insulation resistance @ 70 °C | ≥ 0.012 | MΩ·km | Finished cable, minimum | |
| PVC insulation tensile strength | ≥ 10 | MPa | Type test | |
| PVC insulation elongation at break | ≥ 100 | % | Type test | |
| Insulation colour | Black / red / blue / yellow-green | — | Standard; custom colour combinations available | |
| 04 · Assembly | ||||
| Core arrangement | Four cores cabled in square / flat lay-up | — | Round 4-core lay-up (3P+N) | |
| Filler | None (interstices filled by extrusion) | — | Compact round shape | |
| Binder tape | Not required | — | Sheath extrudes over the quad | |
| Assembled core Ø | ≈ 6.0 | mm | Derived: 7.6 − 2 × 0.8 sheath | |
| Lay-up direction | Right-hand (S) | — | Standard convention | |
| 05 · Sheath | ||||
| Sheath material | PVC, PVC/ST5 compound | — | Black or custom colour | |
| Sheath thickness | 0.8 | mm | Per GB/T 5023.5 for ≈ 6.0 mm assembled Ø | |
| Overall finished diameter | ≈ 7.6 | mm | Cross-referenced industry 4-core sample | |
| Approximate cable mass | ≈ 105 | kg/km | Cross-referenced industry data | |
| PVC sheath tensile strength | ≥ 10 | MPa | Type test | |
| PVC sheath elongation at break | ≥ 125 | % | Type test | |
| Mass per 100 m | ≈ 10.5 | kg/100 m | For reel / carton loading estimation | |
| 06 · Electrical | ||||
| Rated voltage U0/U | 300/500 | V | AC 50 Hz | |
| Maximum system voltage Um | 500 | V | — | |
| DC resistance @ 20 °C | ≤ 26.0 | Ω/km | GB/T 3956 Class 5 | |
| AC impedance @ 50 Hz | ≈ 26.0 | Ω/km | R-dominant; negligible reactance | |
| Capacitance (typical) | ≈ 95 | nF/km | Per core (est.) | |
| Insulation resistance @ 70 °C | ≥ 0.012 | MΩ·km | Finished cable, minimum | |
| Routine test voltage | 2.0 kV AC / 5 min | — | Power-frequency withstand, no breakdown | |
| Air ampacity @ 25 °C | ≈ 6 | A | Four cores loaded, Cu (est.) | |
| Voltage drop @ 6 A | ≈ 0.31 | V/m | 2 × 26.0 × 6 / 1000 (est.) | |
| 07 · Thermal | ||||
| Max continuous conductor temp. | 70 | °C | PVC rated | |
| Max ambient temp. (service) | +70 | °C | Conductor-limited | |
| Min ambient temp. (service) | −15 | °C | PVC flexibility limit | |
| Min laying temperature | 0 | °C | Warm reels below 0 °C | |
| Thermal coefficient of resistance (Cu) | 0.00393 | 1/°C | At 20 °C reference | |
| 08 · Flame (flammability) | ||||
| Flame-retardant behaviour | Non-flame-spreading | — | Per GB/T 18380.12 (IEC 60332-1) | |
| Halogen content | Halogen-bearing (PVC) | — | Emits HCl under fire | |
| Smoke emission | Emits smoke under fire | — | PVC insulation and sheath | |
| Special LSZH version | Not standard | — | Specify LSZH variant for public areas | |
| 09 · Installation | ||||
| Min bending radius (flexible cord) | ≥ 6 × OD ≈ 46 | mm | OD = actual finished diameter | |
| Max pulling tension | ≤ 45 | N | ≈ 20 N/mm² of total copper area (est.) | |
| Laying methods | Fixed wiring inside appliances, ducting, trunking | — | Indoor dry locations | |
| Outdoor / burial note | Not for direct burial or outdoor UV exposure | — | Use UV-stabilised or armoured cable if required | |
| Termination | Solder, crimp ferrule or screw terminal | — | Strip 8–10 mm for flexible Class 5 conductors | |
| Flexing / flexible use | Suitable for occasional movement | — | Not for continuous repetitive flexing (use H05VV5-F if so) | |
| 10 · Packing | ||||
| Standard supply length | 100 | m/reel or carton | Custom lengths available | |
| Reel / packing type | Plastic reel or carton | — | Sealed until installation | |
| Surface marking | Type, voltage, supplier, year, metre marks | — | Per GB/T 6995 | |
| Storage conditions | Dry, covered, −15 to +40 °C | — | Away from sunlight, moisture, oils, sharp objects | |
| Transport | Reels secured against rolling | — | Do not drag cable over rough ground | |
Cable Test Parameters
| Test Parameters — RVV 4×0.75 mm² | ||||
| No. | Test Item | Test Condition / Method | Requirement | Type |
| 1 | Conductor DC resistance | GB/T 3048.4, 20 °C | ≤ 26.0 Ω/km per conductor | Routine |
| 2 | Power-frequency withstand | 2.0 kV AC, 5 min | No breakdown | Routine |
| 3 | Insulation resistance @ 70 °C | GB/T 3048.5, 70 °C | ≥ 0.012 MΩ·km | Routine |
| 4 | Conductor continuity | Visual + electrical | All four cores continuous | Routine |
| 5 | Dimensional check | Micrometer | Insulation ≥ 0.6 mm; sheath ≥ 0.8 mm; OD ≈ 7.6 mm | Routine |
| 6 | PVC insulation tensile & elongation | GB/T 2951.11 | Tensile ≥ 10 MPa; elongation ≥ 100 % | Type |
| 7 | PVC sheath tensile & elongation | GB/T 2951.11 | Tensile ≥ 10 MPa; elongation ≥ 125 % | Type |
| 8 | PVC heat deformation | 80 °C, 4 h, load | Deformation ≤ 50 % | Type |
| 9 | PVC shrinkage test | 150 °C, 1 h | Shrinkage ≤ 4 % | Type |
| 10 | Single-cable vertical flame | GB/T 18380.12 | Self-extinguishing; char ≤ 50 mm above burner | Type |
| 11 | Bending / flexing test | ≥ 6 × OD mandrel | No crack in insulation or sheath | Type |
| 12 | Cold bend test | −15 °C, 4 h | No cracking after mandrel bend | Type |
| 13 | Ozone / weathering (outdoor variant) | As required | Per customer specification | Optional |
| 14 | Voltage test after bending | 2.0 kV AC, 5 min | No breakdown after flexing | Type |
| 15 | Marking legibility | Visual + rubbing | Type/voltage/supplier/metre marks legible | Routine |
| 16 | Core identification | Visual + continuity | Correct colour-coded conductors identified | Routine |
Cable Cross Section Structure

| RVV 4×0.75 mm² — Cross-Section Construction Diagram (Schematic) | |||||
| Layered 4-core flexible build-up from fine copper strands to PVC jacket · nominal dimensions per GB/T 5023.5 / IEC 60227-5 · finished Ø ≈ 7.6 mm per cross-referenced industry sample | |||||
| No. | Layer | Material / Construction | Nominal Thickness (mm) | Diameter (mm) | Function / Remarks |
| 1 | Conductor (Cu) × 4 | Annealed copper, Class 5 flexible stranded — 24 wires of 0.20 mm per core (1+6+12+5 layout), nominal area 0.75 mm² each | — | ≈ 1.1 (Ø each conductor) | Flexive line conductors; DC resistance capped at 26.0 Ω/km at 20 °C |
| 2 | Insulation (PVC) × 4 | PVC compound, PVC/C (TI1) | 0.6 | ≈ 2.3 (Ø each insulated core) | Electrical isolation; 70 °C continuous rating; withstands 2.0 kV for 5 min |
| 3 | Core assembly | Four insulated cores cabled in square lay-up; interstices filled by sheath extrusion | — | ≈ 6.0 (Ø over assembled cores) | Round 4-core lay-up (3P+N); derived from finished Ø 7.6 − 2×0.8 sheath |
| 4 | Outer sheath (PVC) | PVC compound, PVC/ST5, black or custom | 0.8 | ≈ 7.6 (Ø finished cable) | Mechanical protection and abrasion resistance; non-flame-spreading per GB/T 18380.12 |
| Key Dimensions & Properties (expanded) | |||||
| Finished cable diameter | ≈ 7.6 | mm | Cross-referenced industry 4-core sample | ||
| Approximate cable mass | ≈ 105 | kg/km | Cu build-up (cross-referenced industry data) | ||
| Nominal voltage rating | 300/500 | V | AC 50 Hz; maximum system voltage Um = 500 V | ||
| Conductor temperature limit | 70 | °C | Continuous service | ||
| Minimum bend radius (flexible) | ≥ 6 × OD ≈ 46 | mm | OD = actual finished cable diameter | ||
| Flame behaviour | Non-flame-spreading | — | Per GB/T 18380.12 | ||
| Conductor DC resistance | ≤ 26.0 | Ω/km | At 20 °C, per GB/T 3956 Class 5 | ||
| Insulation resistance @ 70 °C | ≥ 0.012 | MΩ·km | Finished cable, minimum | ||
| Routine test voltage | 2.0 kV AC / 5 min | — | Power-frequency withstand | ||
| AC impedance @ 50 Hz | ≈ 26.0 | Ω/km | R-dominant (est.) | ||
| Capacitance (typical) | ≈ 95 | nF/km | Per core (est.) | ||
| Air ampacity @ 25 °C | ≈ 6 | A | Four cores loaded, Cu (est.) | ||
| Voltage drop @ 6 A | ≈ 0.31 | V/m | Loop drop (est.) | ||
| Maximum pulling tension | ≤ 45 | N | ≈ 20 N/mm² of total copper area (est.) | ||
| Mass per 100 m | ≈ 10.5 | kg/100 m | For reel / carton loading | ||
| Schematic — not to exact scale. Finished Ø ≈ 7.6 mm and weight ≈ 105 kg/km from cross-referenced industry samples; conductor/insulation diameters calculated from GB/T 3956 and GB/T 5023.5; ampacity 6 A is an engineering estimate for 4-core flexible cords. Values marked (est.) require confirmation against the factory test certificate. | |||||
Cable Construction Description
| Construction Description — RVV 4×0.75 mm² | |||
| Layer-by-layer build-up narrative, conductor through outer jacket · per GB/T 5023.5 & IEC 60227-5 · CU / PVC / PVC · 300/500 V class · finished Ø ≈ 7.6 mm (cross-referenced industry sample) | |||
| 1. Product Identity & Ratings | |||
| RVV 4×0.75 is a four-core flexible PVC-insulated PVC-sheathed cord rated at 300/500 V AC (50 Hz) and 70 °C conductor temperature, built around four 0.75 mm² annealed copper Class 5 flexible conductors — each PVC-insulated and collectively jacketed in a second PVC oversheath. Manufactured and type-tested to GB/T 5023.5 (60227 IEC 52) / IEC 60227-5, with flexible conductors per GB/T 3956. Finished diameter is about 7.6 mm and nominal mass about 105 kg/km (≈ 10.5 kg per 100 m), supplied on 100 m reels or cartons. With all four cores energised, the cord carries about 6 A in free air at 25 °C (engineering estimate) — a compact four-core interconnection for three-phase-plus-neutral or multi-circuit signal duties. | |||
| 2. Flexible Copper Conductors | |||
| Each 0.75 mm² conductor is stranded from twenty-four 0.20 mm annealed wires in the 1+6+12+5 arrangement — the Class 5 flexible standard at this cross-section — giving a strand-lay diameter of about 1.1 mm and a DC resistance ceiling of 26.0 Ω/km at 20 °C (about 33.0 Ω/km at the 70 °C operating point). The fine-wire bundle gives the cord excellent flexibility and bend endurance. Copper mass is about 6.7 kg/km per core, 26.7 kg/km in total. | |||
| 3. PVC Insulation | |||
| PVC is extruded at 0.60 mm onto each 0.75 mm² conductor, producing approximately 2.3 mm per insulated core. The insulation is rated for 70 °C continuous duty, passes the routine 2.0 kV AC five-minute voltage proof, and maintains insulation resistance above 0.012 MΩ·km at 70 °C. Standard colours are black, red, blue and yellow-green (three-phase plus protective earth), and custom colour combinations can be specified to order. | |||
| 4. Cabling & PVC Outer Jacket | |||
| After insulation, the four cores are cabled in a square lay-up; interstices are filled by the extruded sheath itself, forming a compact round bundle of about 6.0 mm diameter. A 0.80 mm layer of PVC (ST5 compound) is then extruded over the quad to the ≈ 7.6 mm finish. The jacket provides abrasion resistance and mechanical protection, and the whole cord meets the single-cable vertical flame test GB/T 18380.12. Because both insulation and sheath are halogenated PVC, the cord emits smoke and HCl in a fire; for public or confined spaces, specify a low-smoke zero-halogen variant. | |||
| 5. Site Handling & Operational Notes | |||
| • Observe the 6 × OD minimum bending radius (≈ 46 mm). • Strip 8–10 mm for termination and always use a ferrule on the flexible Class 5 strands to prevent wire fraying. • Service ambient spans −15 to +70 °C; warm reels indoors before pulling below 0 °C. • The 6 A reference requires derating for ambient temperature and bundling. • Maximum pulling tension ≤ 45 N; do not use the cord as a pulling rope. • Not for direct burial, outdoor UV exposure or continuous repetitive flexing — for those duties choose an armoured cable, UV-stabilised jacket or a continuous-flex (trunking) cable respectively. • Use reels with flanges suited to the ≈ 7.6 mm OD. |
8. Factory Advantages.
- Fine-strand flexibility — Class 5/6 soft wire dresses easily and resists work-hardening on bends.
- Clean extruded PVC — even insulation and jacket layers every run.
- Tight diameter control — ≈8.5 mm fits control glands, connectors and light chains.
- Length-on-demand — cut to the exact panel-to-device or sensor run.
- Multi-core color coding — pre-colored/numbered cores match the wiring schedule.
- Continuous print line — type, size and voltage readable along the cord.
- Lightweight reel pack — low mass on a coil or small drum with sealed ends.
- RVVP screened variant — braid/foil shield for EMI-sensitive signal.
- Certified QA pack — routine resistance, voltage and continuity records per batch.

9. Packaging, Storage & Logistics. Cut to measured control-run length on a coil or small drum with sealed ends; store dry indoor, shaded, avoid UV.

10. Procurement Specification. State "RVV 4×0.75", length, core colors/numbers and whether a flame-retardant or screened (RVVP) grade is required; request the routine test record. Ferrules recommended on fine strands. Est. values confirmed against the factory certificate.
11. Cable Industry FAQ.
- Q1: How does RVV 4×0.75 differ from RVV 2×1.5? Different core count and duty: four small 0.75 cores in one jacket vs two larger 1.5 cores — R 24.5 vs 16.4 Ω/km, OD 8.5 vs 7.5 mm, ≈8 A per core in a bundle vs ≈16 A per core; the 4×0.75 runs several low-energy control/signal circuits, the 2×1.5 carries a small two-wire power/control feed.
- Q2: Why four cores at 0.75 rather than two at 1.5? Where four separate low-energy circuits (supply + return + two signals) share one jacket, a multi-core cord saves a separate cable per circuit.
- Q3: Why ferrules on the ends? Fine Class 5/6 strands can stray at screw terminals; a cord-end ferrule gives a solid, reliable termination.
- Q4: DC resistance? ≤24.5 Ω/km at 20°C for each flexible 0.75 mm² core.
- Q5: Need shielding? Add RVVP braid/foil near analog signal EMI; standard RVV is unscreened.
- Q6: Current per core? ≈8 A (est.) in a four-core bundle at 30°C; derate further in enclosed trunking.
- Q7: Bending? ≈51 mm (6×OD); the flexible cord bends tightly but avoid kinking.
- Q8: What temperature? 70 °C PVC class — not 90 °C XLPE.
- Q9: Indoor or outdoor? Indoor panel/sensor preferred; specify UV jacket for exposed runs.
- Q10: Packing? Coil or small drum with sealed ends.
- Q11: What proof ships? Routine resistance, voltage and continuity records; est. values confirmed against certificate.