RVV 4 Core Flexible Control Cable 4x0.75mm2 Stranded Copper Conductor PVC Insulated

RVV 4 Core Flexible Control Cable 4x0.75mm2 Stranded Copper Conductor PVC Insulated

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
RVV-4*0.75mm²

Trading Properties

moq
100 meters
payment method
L/C,T/T
supply capacity
100000 meters per month

Product Summary

RVV-4*0.75mm² Premium RVV 4 Core Control Cable Stranded Copper Conductor PVC Insulated,Outer Sheathed Cable Designation & Meaning Code Meaning R Flexible conductor V PVC insulation V PVC sheath 4×0.75 mm² Four cores of 0.75 mm² copper conductor Construction: Four 0.75 mm² fine-stranded copper ...

Product Details

Highlight:

RVV 4 Core Flexible Cable

,

4 Core Flexible Cable 4x0.75mm2

,

PVC Insulated 4 core control cable

Conductor:
Stranded Copper
Copper:
99.99% Oxygen-free Copper
Insulated:
PVC
Outer Sheath:
PVC
Voltage:
300/500V
Temperature:
70℃
Filler:
PP
Package:
As Requirements
Model Type:
Flexible

Product Description

RVV-4*0.75mm² Premium RVV 4 Core Control Cable Stranded Copper Conductor PVC Insulated,Outer Sheathed

Cable Designation & Meaning

Code

Meaning

R

Flexible conductor 

V

PVC insulation 

V

PVC sheath 

4×0.75 mm²

Four cores of 0.75 mm² copper conductor


Construction: Four 0.75 mm² fine-stranded copper conductors, PVC insulation on each core, PVC outer sheath over twisted cores with filler. No metallic screen/armour as standard (can be added on request as RVVP).

Applicable Standards

  • GB/T 5023.5-2008 / IEC 60227-5 — Polyvinyl chloride insulated flexible cables (cords) — Part 5: Flexible cables
  • GB/T 3956-2008 / IEC 60228 — Conductors of insulated cables (Class 5 flexible)
  • GB/T 18380.12 / IEC 60332-1-2 — Flame propagation test for a single vertical insulated wire
  • GB/T 2951-2008 / IEC 60811 — Common test methods for insulating and sheathing materials

RVV 4 Core Flexible Control Cable 4x0.75mm2 Stranded Copper Conductor PVC Insulated

RVV 4×0.75 mm² — Flexible PVC Insulated PVC Sheathed Multi-Core Control Cord — Specification

1. Overview & Ratings. RVV 4×0.75 is a flexible four-core control cord rated 300/500 V, 70 °C working: four 0.75 mm² fine-strand soft copper cores (Class 5/6) with PVC insulation inside a flexible round PVC sheath. OD ≈ 8.5 mm, ≈ 95 kg/km (est.), ≈ 8 A per core in a four-core bundle at 30 °C (est.). Scope: multi-core control circuits, instrument signal, sensor wiring and relay logic — not a 0.6/1 kV XLPE power feeder.


2. Construction Stack (Inner → Outer, expanded).


Layer / Feature Build Function
Conductors 1–4 4×0.75 soft Cu, Class 5/6, ≈24/0.20 strands R ≤24.5 Ω/km; flexible
Fine-strand stranding Many fine strands bunched & twisted Repeated-bend flexibility
PVC insulation Extruded, ≈0.6 mm, 70°C grade Light 300/500 V dielectric
Four-core cabling Insulated cores cabled 2×2 Compact round cord
Flexible PVC sheath ≈0.9 mm overall Binds cores, abrasion jacket
Optional screen Braid/foil (RVVP variant) EMI signal immunity


3. Electrical Characteristics. R ≤ 24.5 Ω/km @20 °C. Test 2.0 kV AC / 5 min; ≈ 8 A per core in a bundle (est., air 30 °C); 300/500 V; 50/60 Hz; unscreened as standard, RVVP screened variant available.

Insulation & Sheath Data

Property

Value

Insulation material

PVC (Type TI2)

Outer sheath material

PVC (Type ST5)

Long-term service temp.

70 °C (continuous)

Max. conductor temp. (normal)

70 °C

Short-circuit temp. (≤5 s)

160 °C

Emergency overload temp.

100 °C (≤1 h)

Test voltage AC (5 min)

2.0 kV

Dielectric strength

≥ 20 kV/mm

Volume resistivity @20 °C

≥ 1×10¹³ Ω·cm

Shield

None as standard (RVVP available)

Electrical Parameters

Parameter

Value

Note

Rated voltage U₀/U

300 / 500 V

GB/T 5023.5 / IEC 60227-5

Max. system voltage

500 V AC / 700 V DC

—

Test voltage AC (5 min)

2.0 kV

Routine test

DC resistance @20 °C

≤ 26.0 Ω/km per core

GB/T 3956 Class 5 Cu max (0.75 mm²)

AC resistance @70 °C (est.)

≈ 32.0 Ω/km per core

—

Current rating in air (30 °C)

Three-phase AC: 13 A​ (per phase core, 3×L + PE)

4×0.75, touching, in free air

Current rating in tray (30 °C)

Three-phase AC: 15 A​ (per phase core)

4×0.75, spaced

Current rating in conduit (30 °C)

Three-phase AC: 10 A​ (per phase core)

—

Single-phase current capacity

Single-phase AC: 13 A​ (L+N, with 2 cores spare)

—

DC current capacity

13 A​ per core

—

Short-circuit current (1 s, Cu, 160 °C)

≈ 82 A per core

—

Capacitance (core-to-core, approx.)

≈ 0.09 µF/km

PVC

Inductive reactance (approx.)

≈ 0.11 Ω/km

at 50 Hz

Frequency

50/60 Hz AC

—


Reference values: RVV 4×0.75 at 13 A three-phase, 400 V → max load ≈ 9.0 kW​ (cos φ = 1.0). As single-phase at 13 A, 230 V → max load ≈ 3.0 kW​ (cos φ = 1.0). Suitable for three-phase low-current control with earth, multi-core signal wiring, sensor arrays, and instrumentation.


4. Thermal & Flame. 70 °C continuous; standard PVC — specify flame-retardant grade where wiring rules require; indoor control use preferred, not a fire-rated circuit.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

70 °C (continuous)

Max. short-circuit temp. (≤5 s)

160 °C

Emergency overload temp.

100 °C (≤1 h)

Min. installation ambient temp.

−15 °C

Service ambient range

−15 °C to +70 °C

Flexing temp. range

−5 °C to +70 °C

Fire Performance (RVV — Standard, Non-Flame-Retardant)

Property

Value / Requirement

Flame retardant

GB/T 18380.12 / IEC 60332-1-2​ (single cable, self-extinguishing)

Flame retardant class

None​ as standard (use ZC-RVV for Class C)

Halogen content

Contains halogen (PVC)

Smoke density

Not low-smoke

Corrosivity

Corrosive (PVC)

Toxicity

Toxic fumes when burned

EMI shielding

None (use RVVP for shielded version)


5. Installation Practice & Handling. Crimp cord-end ferrules or pins on the fine strands before screw terminals; bend ≥ 6×OD ≈ 51 mm; avoid sharp edges and kinking; verify continuity of all four cores and insulation after dressing.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 6 × OD → ≈ 49 mm at Ø8.2 mm

flexible cable

Max. pulling tension

11.25 N per core (0.75 mm² × 15 N/mm²)

Cu conductor limit

Direct burial

Not recommended (use buried conduit)

—

Surface mounting

Cable tray, conduit, trunking, cable clips

—

Conduit ID

≥ 20 mm

—

Fixing

cable ties, clips

—

Impact resistance

Low (light-duty)

—

Water resistance

Limited (PVC sheath)

—

UV resistance

Poor (PVC degrades outdoors, use UV-resistant or conduit)

—

Flex life

Excellent (Class 5 fine-stranded)

flexible / portable

Termination note

Screw terminals, compression lugs, or direct crimp (ferrule recommended)

—


6. Typical Service Applications. Multi-core control circuits, instrument signal, sensor wiring, relay logic and 4-wire device connections.


RVV 4 Core Flexible Control Cable 4x0.75mm2 Stranded Copper Conductor PVC Insulated


7. Testing & QA Regime (16 items). Routine: DC resistance, 2.0 kV withstand, insulation resistance, continuity, conductor construction, sheath/insulation thickness, dimensional check, core color coding, print legibility, mass, appearance, packing. Type: flame (if grade ordered), flexibility/bending, sheath tensile/elongation.


Cable Parameters


RVV 4×0.75 mm² — Full Parameter Sheet
Copper-core PVC-insulated PVC-sheathed flexible cord · 300/500 V · GB/T 5023.5 / IEC 60227-5 (60227 IEC 52) · finished Ø ≈ 7.6 mm · ≈ 105 kg/km — cross-referenced industry sample data
Section Parameter Value Unit Remarks / Standard
01 · Identification

Cable type RVV — Copper conductor, PVC insulation, PVC sheath, flexible round cord (60227 IEC 52)

Rated voltage (U0/U) 300/500 V AC 50 Hz; maximum system voltage Um = 500 V

Number of cores 4 — Four-core round flexible cord (3P+N)

Nominal cross-sectional area 0.75 × 4 mm² Per conductor

Conductor material Annealed copper (Cu) — Class 5 flexible stranded per GB/T 3956 / IEC 60228

Insulation material PVC, PVC/C (TI1) compound — 70 °C rated

Sheath material PVC, PVC/ST5 compound — Black or custom colour

Standard reference GB/T 5023.5 / IEC 60227-5 — 60227 IEC 52 RVV flexible cords
02 · Conductor

Stranding (per core) 24 × 0.20 mm — Class 5 flexible lay-up

Conductor diameter ≈ 1.1 mm Strand-lay diameter (est.)

DC resistance @ 20 °C ≤ 26.0 Ω/km Maximum per GB/T 3956 Class 5

DC resistance @ 70 °C ≈ 33.0 Ω/km Temperature-corrected (est.)

Copper mass (all cores) ≈ 26.7 kg/km 4 × 0.75 × 8.89 g/cm³

Conductor flexibility Class 5 (flexible) — Suitable for repeated bending / appliance leads
03 · Insulation

Insulation thickness (per core) 0.6 mm GB/T 5023.5 specified for 0.75 mm²

Core Ø over insulation ≈ 2.3 mm 1.1 + 2 × 0.6

Insulation material PVC, PVC/C (TI1) — Thermoplastic, 70 °C rated

Insulation resistance @ 70 °C ≥ 0.012 MΩ·km Finished cable, minimum

PVC insulation tensile strength ≥ 10 MPa Type test

PVC insulation elongation at break ≥ 100 % Type test

Insulation colour Black / red / blue / yellow-green — Standard; custom colour combinations available
04 · Assembly

Core arrangement Four cores cabled in square / flat lay-up — Round 4-core lay-up (3P+N)

Filler None (interstices filled by extrusion) — Compact round shape

Binder tape Not required — Sheath extrudes over the quad

Assembled core Ø ≈ 6.0 mm Derived: 7.6 − 2 × 0.8 sheath

Lay-up direction Right-hand (S) — Standard convention
05 · Sheath

Sheath material PVC, PVC/ST5 compound — Black or custom colour

Sheath thickness 0.8 mm Per GB/T 5023.5 for ≈ 6.0 mm assembled Ø

Overall finished diameter ≈ 7.6 mm Cross-referenced industry 4-core sample

Approximate cable mass ≈ 105 kg/km Cross-referenced industry data

PVC sheath tensile strength ≥ 10 MPa Type test

PVC sheath elongation at break ≥ 125 % Type test

Mass per 100 m ≈ 10.5 kg/100 m For reel / carton loading estimation
06 · Electrical

Rated voltage U0/U 300/500 V AC 50 Hz

Maximum system voltage Um 500 V —

DC resistance @ 20 °C ≤ 26.0 Ω/km GB/T 3956 Class 5

AC impedance @ 50 Hz ≈ 26.0 Ω/km R-dominant; negligible reactance

Capacitance (typical) ≈ 95 nF/km Per core (est.)

Insulation resistance @ 70 °C ≥ 0.012 MΩ·km Finished cable, minimum

Routine test voltage 2.0 kV AC / 5 min — Power-frequency withstand, no breakdown

Air ampacity @ 25 °C ≈ 6 A Four cores loaded, Cu (est.)

Voltage drop @ 6 A ≈ 0.31 V/m 2 × 26.0 × 6 / 1000 (est.)
07 · Thermal

Max continuous conductor temp. 70 °C PVC rated

Max ambient temp. (service) +70 °C Conductor-limited

Min ambient temp. (service) −15 °C PVC flexibility limit

Min laying temperature 0 °C Warm reels below 0 °C

Thermal coefficient of resistance (Cu) 0.00393 1/°C At 20 °C reference
08 · Flame (flammability)

Flame-retardant behaviour Non-flame-spreading — Per GB/T 18380.12 (IEC 60332-1)

Halogen content Halogen-bearing (PVC) — Emits HCl under fire

Smoke emission Emits smoke under fire — PVC insulation and sheath

Special LSZH version Not standard — Specify LSZH variant for public areas
09 · Installation

Min bending radius (flexible cord) ≥ 6 × OD ≈ 46 mm OD = actual finished diameter

Max pulling tension ≤ 45 N ≈ 20 N/mm² of total copper area (est.)

Laying methods Fixed wiring inside appliances, ducting, trunking — Indoor dry locations

Outdoor / burial note Not for direct burial or outdoor UV exposure — Use UV-stabilised or armoured cable if required

Termination Solder, crimp ferrule or screw terminal — Strip 8–10 mm for flexible Class 5 conductors

Flexing / flexible use Suitable for occasional movement — Not for continuous repetitive flexing (use H05VV5-F if so)
10 · Packing

Standard supply length 100 m/reel or carton Custom lengths available

Reel / packing type Plastic reel or carton — Sealed until installation

Surface marking Type, voltage, supplier, year, metre marks — Per GB/T 6995

Storage conditions Dry, covered, −15 to +40 °C — Away from sunlight, moisture, oils, sharp objects

Transport Reels secured against rolling — Do not drag cable over rough ground


Cable Test Parameters


Test Parameters — RVV 4×0.75 mm²
No. Test Item Test Condition / Method Requirement Type
1 Conductor DC resistance GB/T 3048.4, 20 °C ≤ 26.0 Ω/km per conductor Routine
2 Power-frequency withstand 2.0 kV AC, 5 min No breakdown Routine
3 Insulation resistance @ 70 °C GB/T 3048.5, 70 °C ≥ 0.012 MΩ·km Routine
4 Conductor continuity Visual + electrical All four cores continuous Routine
5 Dimensional check Micrometer Insulation ≥ 0.6 mm; sheath ≥ 0.8 mm; OD ≈ 7.6 mm Routine
6 PVC insulation tensile & elongation GB/T 2951.11 Tensile ≥ 10 MPa; elongation ≥ 100 % Type
7 PVC sheath tensile & elongation GB/T 2951.11 Tensile ≥ 10 MPa; elongation ≥ 125 % Type
8 PVC heat deformation 80 °C, 4 h, load Deformation ≤ 50 % Type
9 PVC shrinkage test 150 °C, 1 h Shrinkage ≤ 4 % Type
10 Single-cable vertical flame GB/T 18380.12 Self-extinguishing; char ≤ 50 mm above burner Type
11 Bending / flexing test ≥ 6 × OD mandrel No crack in insulation or sheath Type
12 Cold bend test −15 °C, 4 h No cracking after mandrel bend Type
13 Ozone / weathering (outdoor variant) As required Per customer specification Optional
14 Voltage test after bending 2.0 kV AC, 5 min No breakdown after flexing Type
15 Marking legibility Visual + rubbing Type/voltage/supplier/metre marks legible Routine
16 Core identification Visual + continuity Correct colour-coded conductors identified Routine


Cable Cross Section Structure


RVV 4 Core Flexible Control Cable 4x0.75mm2 Stranded Copper Conductor PVC Insulated

RVV 4×0.75 mm² — Cross-Section Construction Diagram (Schematic)
Layered 4-core flexible build-up from fine copper strands to PVC jacket · nominal dimensions per GB/T 5023.5 / IEC 60227-5 · finished Ø ≈ 7.6 mm per cross-referenced industry sample
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductor (Cu) × 4 Annealed copper, Class 5 flexible stranded — 24 wires of 0.20 mm per core (1+6+12+5 layout), nominal area 0.75 mm² each — ≈ 1.1 (Ø each conductor) Flexive line conductors; DC resistance capped at 26.0 Ω/km at 20 °C
2 Insulation (PVC) × 4 PVC compound, PVC/C (TI1) 0.6 ≈ 2.3 (Ø each insulated core) Electrical isolation; 70 °C continuous rating; withstands 2.0 kV for 5 min
3 Core assembly Four insulated cores cabled in square lay-up; interstices filled by sheath extrusion — ≈ 6.0 (Ø over assembled cores) Round 4-core lay-up (3P+N); derived from finished Ø 7.6 − 2×0.8 sheath
4 Outer sheath (PVC) PVC compound, PVC/ST5, black or custom 0.8 ≈ 7.6 (Ø finished cable) Mechanical protection and abrasion resistance; non-flame-spreading per GB/T 18380.12
Key Dimensions & Properties (expanded)
Finished cable diameter ≈ 7.6 mm Cross-referenced industry 4-core sample

Approximate cable mass ≈ 105 kg/km Cu build-up (cross-referenced industry data)

Nominal voltage rating 300/500 V AC 50 Hz; maximum system voltage Um = 500 V

Conductor temperature limit 70 °C Continuous service

Minimum bend radius (flexible) ≥ 6 × OD ≈ 46 mm OD = actual finished cable diameter

Flame behaviour Non-flame-spreading — Per GB/T 18380.12

Conductor DC resistance ≤ 26.0 Ω/km At 20 °C, per GB/T 3956 Class 5

Insulation resistance @ 70 °C ≥ 0.012 MΩ·km Finished cable, minimum

Routine test voltage 2.0 kV AC / 5 min — Power-frequency withstand

AC impedance @ 50 Hz ≈ 26.0 Ω/km R-dominant (est.)

Capacitance (typical) ≈ 95 nF/km Per core (est.)

Air ampacity @ 25 °C ≈ 6 A Four cores loaded, Cu (est.)

Voltage drop @ 6 A ≈ 0.31 V/m Loop drop (est.)

Maximum pulling tension ≤ 45 N ≈ 20 N/mm² of total copper area (est.)

Mass per 100 m ≈ 10.5 kg/100 m For reel / carton loading

Schematic — not to exact scale. Finished Ø ≈ 7.6 mm and weight ≈ 105 kg/km from cross-referenced industry samples; conductor/insulation diameters calculated from GB/T 3956 and GB/T 5023.5; ampacity 6 A is an engineering estimate for 4-core flexible cords. Values marked (est.) require confirmation against the factory test certificate.


Cable Construction Description


Construction Description — RVV 4×0.75 mm² 
Layer-by-layer build-up narrative, conductor through outer jacket · per GB/T 5023.5 & IEC 60227-5 · CU / PVC / PVC · 300/500 V class · finished Ø ≈ 7.6 mm (cross-referenced industry sample)
1. Product Identity & Ratings
RVV 4×0.75 is a four-core flexible PVC-insulated PVC-sheathed cord rated at 300/500 V AC (50 Hz) and 70 °C conductor temperature, built around four 0.75 mm² annealed copper Class 5 flexible conductors — each PVC-insulated and collectively jacketed in a second PVC oversheath. Manufactured and type-tested to GB/T 5023.5 (60227 IEC 52) / IEC 60227-5, with flexible conductors per GB/T 3956. Finished diameter is about 7.6 mm and nominal mass about 105 kg/km (≈ 10.5 kg per 100 m), supplied on 100 m reels or cartons. With all four cores energised, the cord carries about 6 A in free air at 25 °C (engineering estimate) — a compact four-core interconnection for three-phase-plus-neutral or multi-circuit signal duties.
2. Flexible Copper Conductors
Each 0.75 mm² conductor is stranded from twenty-four 0.20 mm annealed wires in the 1+6+12+5 arrangement — the Class 5 flexible standard at this cross-section — giving a strand-lay diameter of about 1.1 mm and a DC resistance ceiling of 26.0 Ω/km at 20 °C (about 33.0 Ω/km at the 70 °C operating point). The fine-wire bundle gives the cord excellent flexibility and bend endurance. Copper mass is about 6.7 kg/km per core, 26.7 kg/km in total.
3. PVC Insulation
PVC is extruded at 0.60 mm onto each 0.75 mm² conductor, producing approximately 2.3 mm per insulated core. The insulation is rated for 70 °C continuous duty, passes the routine 2.0 kV AC five-minute voltage proof, and maintains insulation resistance above 0.012 MΩ·km at 70 °C. Standard colours are black, red, blue and yellow-green (three-phase plus protective earth), and custom colour combinations can be specified to order.
4. Cabling & PVC Outer Jacket
After insulation, the four cores are cabled in a square lay-up; interstices are filled by the extruded sheath itself, forming a compact round bundle of about 6.0 mm diameter. A 0.80 mm layer of PVC (ST5 compound) is then extruded over the quad to the ≈ 7.6 mm finish. The jacket provides abrasion resistance and mechanical protection, and the whole cord meets the single-cable vertical flame test GB/T 18380.12. Because both insulation and sheath are halogenated PVC, the cord emits smoke and HCl in a fire; for public or confined spaces, specify a low-smoke zero-halogen variant.
5. Site Handling & Operational Notes
• Observe the 6 × OD minimum bending radius (≈ 46 mm).  • Strip 8–10 mm for termination and always use a ferrule on the flexible Class 5 strands to prevent wire fraying.  • Service ambient spans −15 to +70 °C; warm reels indoors before pulling below 0 °C.  • The 6 A reference requires derating for ambient temperature and bundling.  • Maximum pulling tension ≤ 45 N; do not use the cord as a pulling rope.  • Not for direct burial, outdoor UV exposure or continuous repetitive flexing — for those duties choose an armoured cable, UV-stabilised jacket or a continuous-flex (trunking) cable respectively.  • Use reels with flanges suited to the ≈ 7.6 mm OD.


8. Factory Advantages.

  • Fine-strand flexibility — Class 5/6 soft wire dresses easily and resists work-hardening on bends.
  • Clean extruded PVC — even insulation and jacket layers every run.
  • Tight diameter control — ≈8.5 mm fits control glands, connectors and light chains.
  • Length-on-demand — cut to the exact panel-to-device or sensor run.
  • Multi-core color coding — pre-colored/numbered cores match the wiring schedule.
  • Continuous print line — type, size and voltage readable along the cord.
  • Lightweight reel pack — low mass on a coil or small drum with sealed ends.
  • RVVP screened variant — braid/foil shield for EMI-sensitive signal.
  • Certified QA pack — routine resistance, voltage and continuity records per batch.

RVV 4 Core Flexible Control Cable 4x0.75mm2 Stranded Copper Conductor PVC Insulated


9. Packaging, Storage & Logistics. Cut to measured control-run length on a coil or small drum with sealed ends; store dry indoor, shaded, avoid UV.

RVV 4 Core Flexible Control Cable 4x0.75mm2 Stranded Copper Conductor PVC Insulated


10. Procurement Specification. State "RVV 4×0.75", length, core colors/numbers and whether a flame-retardant or screened (RVVP) grade is required; request the routine test record. Ferrules recommended on fine strands. Est. values confirmed against the factory certificate.


11. Cable Industry FAQ.

  • Q1: How does RVV 4×0.75 differ from RVV 2×1.5? Different core count and duty: four small 0.75 cores in one jacket vs two larger 1.5 cores — R 24.5 vs 16.4 Ω/km, OD 8.5 vs 7.5 mm, ≈8 A per core in a bundle vs ≈16 A per core; the 4×0.75 runs several low-energy control/signal circuits, the 2×1.5 carries a small two-wire power/control feed.
  • Q2: Why four cores at 0.75 rather than two at 1.5? Where four separate low-energy circuits (supply + return + two signals) share one jacket, a multi-core cord saves a separate cable per circuit.
  • Q3: Why ferrules on the ends? Fine Class 5/6 strands can stray at screw terminals; a cord-end ferrule gives a solid, reliable termination.
  • Q4: DC resistance? ≤24.5 Ω/km at 20°C for each flexible 0.75 mm² core.
  • Q5: Need shielding? Add RVVP braid/foil near analog signal EMI; standard RVV is unscreened.
  • Q6: Current per core? ≈8 A (est.) in a four-core bundle at 30°C; derate further in enclosed trunking.
  • Q7: Bending? ≈51 mm (6×OD); the flexible cord bends tightly but avoid kinking.
  • Q8: What temperature? 70 °C PVC class — not 90 °C XLPE.
  • Q9: Indoor or outdoor? Indoor panel/sensor preferred; specify UV jacket for exposed runs.
  • Q10: Packing? Coil or small drum with sealed ends.
  • Q11: What proof ships? Routine resistance, voltage and continuity records; est. values confirmed against certificate.