RVVP 4x2.5mm² Shielded Control Cable High Load Anti-Interference Cable for Industrial Actuator and Motor Control
Product Summary
Product Details
RVVP shielded control cable
,4x2.5mm² anti-interference cable
,4 core flexible motor cable
Product Description
RVVP 4x2.5mm² Shielded Control Cable High Load Anti-Interference Cable for Industrial Actuator and Motor Control
Cable Designation & Meaning
|
Code |
Meaning |
|---|---|
|
R |
Flexible cord |
|
V |
PVC insulation |
|
V |
PVC sheath |
|
P |
Copper braid shield |
|
4×2.5 mm² |
Four cores of 2.5 mm² copper conductor |
Construction: Four 2.5 mm² fine-stranded copper conductors, PVC insulation on each core, laid up together, tinned copper braid shield (≥80% coverage) over the laid-up cores, PVC outer sheath.
Applicable Standards
- GB/T 5023.5-2008 / IEC 60227-5 — Polyvinyl chloride insulated cables — Flexible cables (cords)
- GB/T 3956-2008 / IEC 60228 — Conductors of insulated cables (Class 5 flexible)
- GB/T 18380.3 / IEC 60332-3 — Flame retardant (Category A/B/C as specified)
- GB/T 5023.2-2008 / IEC 60227-2 — Test methods
RVVP 4×2.5 mm² — Flexible Shielded Power+Control Cable — Specification
1. Overview & Ratings
RVVP 4×2.5 is a 4-core shielded power+control cable rated 300/500 V. It uses pure annealed bare copper (not tinned) for both the conductor and braid, maximizing conductivity. The four 2.5 mm² cores are laid up in a quad formation and handle motor power circuits, small transformer supply, and power distribution with control. The braid suppresses EMI/RFI from nearby VFDs and motors. OD ≈ 13.5 mm, ≈ 175 kg/km (est.), ≈ 16–22 A. Max conductor temperature 70 °C, -15 to +70 °C. Intended for dry indoor power and control circuits; for damp or outdoor duty, specify tinned copper variant.
2. Construction Stack (Inner → Outer, expanded)
| Layer / Feature | Build | Function |
|---|---|---|
| Conductor (×4) | Pure annealed Cu, Class 5, 50×0.25 mm per core | R ≤ 7.41 Ω/km, power + control |
| Insulation | PVC ≈ 0.8 mm per core | 300/500 V dielectric, power/control coding |
| Inner sheath | PVC + filler ≈ 0.8 mm | Round bedding for quad core lay |
| Braid shield | Pure Cu, ≈ 85% coverage | Low transfer impedance for power + control |
| Outer jacket | PVC ≈ 1.1 mm | Robust oil/abrasion protection |
3. Electrical Characteristics
DC resistance ≤ 7.41 Ω/km at 20 °C per GB/T 3956 Class 5 pure copper — roughly 44% lower than 1.5 mm², making it suitable for motor power and transformer supply. Rated voltage 300/500 V. Estimated ampacity ≈ 16–22 A in free air at 30 °C. Insulation resistance ≥ 20 MΩ·km. Routine AC withstand test at 2000 V for 5 minutes. Typical capacitance ≈ 180 pF/m at 1 kHz. The pure copper braid provides ≈ 60–70 dB shielding at 30–1000 MHz. Voltage drop ≈ 1.48 V per 100 m at 20 A — suitable for motor power runs up to 40 m.
Insulation & Sheath Data
|
Property |
Value |
|---|---|
|
Insulation material |
PVC (Type TI2) |
|
Outer sheath material |
PVC (Type TM2) |
|
Shield material |
Tinned copper braid |
|
Long-term service temp. |
70 °C (continuous) |
|
Max. conductor temp. (normal) |
70 °C |
|
Short-circuit temp. (≤5 s) |
160 °C |
|
Emergency overload temp. |
100 °C (≤1 h) |
|
Test voltage AC (5 min) |
2.0 kV |
|
Dielectric strength |
≥ 20 kV/mm |
|
Volume resistivity @20 °C |
≥ 1×10¹² Ω·cm |
|
Shield |
Pure copper braid, ≥ 80% coverage (EMI/RFI protection) |
Electrical Parameters
|
Parameter |
Value |
Note |
|---|---|---|
|
Rated voltage U₀/U |
300 / 300 V |
GB/T 5023.5 (control/signal) |
|
Max. system voltage |
350 V AC / 500 V DC |
— |
|
Test voltage AC (5 min) |
2.0 kV |
Routine test |
|
DC resistance @20 °C |
≤ 7.98 Ω/km per core |
GB/T 3956 Class 5 Cu max (2.5 mm²) |
|
AC resistance @70 °C (est.) |
≈ 10.0 Ω/km per core |
— |
|
Current rating in air (30 °C) |
Control/low-power: 16 A per core (recommended max.) |
conservative control rating |
|
Current rating in tray (30 °C) |
Control/low-power: 18 A per core |
— |
|
DC current capacity |
16 A per core |
— |
|
Short-circuit current (1 s, Cu, 160 °C) |
≈ 275 A per core |
— |
|
Capacitance (core-to-core, approx.) |
≈ 0.15 µF/km |
PVC |
|
Capacitance (core-to-shield, approx.) |
≈ 0.24 µF/km |
PVC |
|
Inductive reactance (approx.) |
≈ 0.08 Ω/km |
at 50 Hz |
|
Frequency |
DC / up to 100 MHz (signal) |
— |
|
Characteristic impedance (approx.) |
50 – 70 Ω |
signal reference |
|
Attenuation (at 1 MHz, approx.) |
≈ 0.42 dB/100 m |
— |
Reference values: RVVP 4×2.5 at 16 A per core, 24 V DC → max load ≈ 384 W per core (low-power device supply). At 230 V AC → max load ≈ 3,680 VA per core (not recommended for power).
4. Thermal & Flame Behaviour
Operating range -15 to +70 °C continuous. Short-circuit withstand up to 160 °C for ≤ 5 seconds. PVC insulation and jacket are flame-retardant per IEC 60332-1. The cable is halogen-containing (PVC), emitting HCl gas on burning — avoid in enclosed switchrooms. For public or enclosed spaces, specify LSZH alternatives. The 1.1 mm Type ST jacket is oil- and abrasion-resistant for machine and panel wiring. Note: bare pure copper oxidizes in humid environments — install in dry indoor or conduit-protected locations. UV resistance is limited.
Temperature Characteristics
|
Property |
Value |
|---|---|
|
Max. conductor operating temp. |
70 °C (continuous) |
|
Max. short-circuit temp. (≤5 s) |
160 °C |
|
Emergency overload temp. |
100 °C (≤1 h) |
|
Min. installation ambient temp. |
−15 °C |
|
Service ambient range |
−15 °C to +70 °C |
|
Flexing temp. range |
−5 °C to +70 °C |
Fire Performance (RVVP — PVC, Non-Low-Smoke)
|
Property |
Value / Requirement |
|---|---|
|
Flame retardant |
GB/T 18380.3 / IEC 60332-3 (Category A/B/C as specified) |
|
Halogen content |
Contains halogen (PVC) |
|
Smoke density |
Not low-smoke (IEC 61034-2 not applicable) |
|
Corrosivity |
Corrosive (HCl emission from PVC) |
|
Toxicity |
Toxic fumes when burned (CO, HCl) |
|
EMI shielding |
Excellent (tinned copper braid, ≥85% coverage) |
|
UV resistance |
Poor (PVC degrades outdoors, use conduit or UV-resistant) |
|
Water resistance |
Limited (PVC sheath) |
5. Installation Practice & Handling
Minimum bending radius ≥ 6×OD ≈ 81 mm for fixed installation; 12×OD ≈ 162 mm for drag-chain applications. The 13.5 mm OD and 175 kg/km make the cable robust yet flexible for routing in control panels, through conduits and along machine frames. When terminating, connect the braid shield to earth at one end (or both ends per system design) using a shield gland or drain wire. Use ferrules on the 50-strand conductors. Route the cable away from high-power motor cables by at least 300 mm. After installation, verify insulation resistance, shield continuity and 4-wire polarity before energizing.
Mechanical & Installation Parameters
|
Parameter |
Value |
Remarks |
|---|---|---|
|
Minimum bending radius |
≥ 6 × OD → ≈ 73 mm at Ø12.2 mm |
flexible cable |
|
Max. pulling tension |
37.5 N per core (2.5 mm² × 15 N/mm²) |
Cu conductor limit |
|
Direct burial |
Not recommended (PVC, non-UV, water ingress) |
— |
|
Surface mounting |
Cable tray, conduit, trunking, DIN rail |
— |
|
Conduit ID |
≥ 40 mm |
— |
|
Fixing |
cable ties, clamps, clips |
— |
|
Impact resistance |
Low (PVC) |
— |
|
Water resistance |
Limited (PVC sheath) |
— |
|
UV resistance |
Poor (indoor/conduit only) |
— |
|
Flex life |
Excellent (Class 5 fine-stranded) |
flexible routing |
|
Termination note |
Compression lugs (2.5 mm²), crimp terminals, screw terminals |
— |
6. Typical Service Applications
Motor power circuits for small 0.5–2.2 kW motors, small transformer supply for control panels, power distribution with control (L/N/PE/control), 4-wire power + control + signal for machines, and interconnection between control panels and field devices. The 2.5 mm² cross-section carries enough current for small motor power while the braid shield suppresses EMI from nearby VFDs and servo drives. Particularly suitable for packaging machines, textile machinery, and production lines where motor power and control circuits share the same cable. Not for: mains AC power distribution above 500 V, high-speed fieldbus, direct burial, or outdoor UV-exposed runs.

7. Testing & Quality Assurance Regime
Routine tests (100% production): DC resistance, AC voltage withstand (2000 V/5 min), insulation resistance, conductor construction, wall thickness, dimensional check, print legibility, mass per length, visual appearance, and packing. Type tests (per batch / material change): shield coverage, heat aging (100 °C/7 days), cold bend (-15 °C), jacket tensile, flame retardancy, and shielding effectiveness. Every coil ships with mill test certificate, ROHS and REACH declarations. The 300/500 V rating uses a 2000 V withstand test.
Cable Parameters
| RVVP 4×2.5 mm² — Full Parameter Sheet | ||||
| Shielded flexible power+control cable · 300/500 V · pure annealed Cu Class 5 · PVC insulation/jacket · pure Cu braid ≈ 85% · 4-core quad formation · GB/T 9330 / IEC 60227 | ||||
| Section | Parameter | Value | Unit | Remarks / Standard |
| 01 · Identification | ||||
| Cable type | RVVP | — | Flexible pure Cu, PVC ins., PVC jacket, braid shield | |
| Rated voltage (U0/U) | 300/500 | V | Power / control / signal | |
| Number of cores | 4 | — | 4 cores, quad formation, colour-coded | |
| Nominal cross-section | 2.5 | mm² | Per core, Class 5 flexible | |
| Conductor material | Pure annealed copper (bare) | — | Class 5 per GB/T 3956, not tinned | |
| Insulation material | PVC (Type SP) | — | 70 °C rated, 0.8 mm wall | |
| Shield | Pure copper braid | — | ≈ 85% coverage, low transfer impedance | |
| Outer jacket material | PVC (Type ST) | — | Oil/abrasion resistant, 1.1 mm | |
| Standard reference | GB/T 9330 / IEC 60227 / UL 2464 | — | Harmonized control cable | |
| 02 · Conductor | ||||
| Stranding | 50 × 0.25 mm | — | Class 5 pure copper per core | |
| Conductor diameter | ≈ 2.0 | mm | Per core, strand-lay | |
| DC resistance @ 20 °C | ≤ 7.41 | Ω/km | Maximum per GB/T 3956 (pure Cu) | |
| Conductor surface | Bare pure copper | — | Not tinned; for dry indoor use | |
| 03 · Insulation | ||||
| Insulation type | PVC (Type SP) | — | Soft PVC, 70 °C | |
| Insulation thickness | ≈ 0.8 | mm | Nominal | |
| Insulated core Ø | ≈ 3.6 | mm | Per core | |
| Insulation resistance | ≥ 20 | MΩ·km | At 20 °C | |
| 04 · Shield & Inner Sheath | ||||
| Inner sheath material | PVC + polyester filler | — | Bedding over quad core lay | |
| Inner sheath thickness | ≈ 0.8 | mm | Nominal | |
| Shield type | Pure Cu braid | — | Woven over inner sheath | |
| Shield coverage | ≈ 85 | % | Typical | |
| Shielding effectiveness | ≈ 60–70 | dB | At 30–1000 MHz | |
| 05 · Outer Jacket | ||||
| Jacket material | PVC (Type ST) | — | Oil/abrasion resistant | |
| Jacket thickness | ≈ 1.1 | mm | Nominal | |
| Overall finished diameter | ≈ 13.5 | mm | 4-core shielded power+control cable | |
| Approximate cable mass | ≈ 175 | kg/km | Pure Cu + PVC + braid | |
| Mass per 100 m | ≈ 17.5 | kg/100 m | For drum loading | |
| 06 · Electrical | ||||
| Rated voltage | 300/500 | V | Power / control | |
| Test voltage (AC) | 2000 | V AC | 5 min routine | |
| DC resistance @ 20 °C | ≤ 7.41 | Ω/km | Per GB/T 3956 (pure Cu) | |
| Ampacity (free air) | ≈ 16–22 | A | 2.5 mm², 70 °C | |
| Voltage drop @ 20 A / 100 m | ≈ 1.48 | V | I × R | |
| Capacitance (core-core) | ≈ 180 | pF/m | At 1 kHz | |
| 07 · Thermal & Mechanical | ||||
| Max continuous conductor temp. | 70 | °C | Normal service | |
| Short-circuit temp. (≤5 s) | 160 | °C | Copper limit | |
| Min. ambient temp. | -15 | °C | Fixed installation | |
| Min. bending radius | ≥ 6 × OD ≈ 81 | mm | Fixed; 12× for moving | |
| Halogen content | Halogen-containing | — | PVC compound | |
| 08 · Flame & Environment | ||||
| Flame retardancy | IEC 60332-1 | — | Single vertical flame | |
| Oil resistance | Good | — | Type ST PVC | |
| UV resistance | Limited | — | Indoor / conduit use | |
| Corrosion resistance | Limited (bare Cu) | — | Dry indoor only; use tinned for damp/outdoor | |
| ROHS / REACH | Compliant | — | EU 2011/65/EU | |
Cable Test Parameters
| Test Parameters — RVVP 4×2.5 mm² | ||||
| No. | Test Item | Test Condition / Method | Requirement | Type |
| 1 | Conductor DC resistance | GB/T 3956, 20 °C | ≤ 7.41 Ω/km | Routine |
| 2 | AC voltage withstand | 2000 V AC, 5 min | No breakdown | Routine |
| 3 | Insulation resistance | 500 V megohmmeter | ≥ 20 MΩ·km | Routine |
| 4 | Conductor construction | Visual + strand count | 50 × 0.25 mm pure Cu per core | Routine |
| 5 | Wall thickness | Micrometer cross-section | Ins. ≈ 0.8 mm; jacket ≈ 1.1 mm | Routine |
| 6 | Dimensional check | Caliper | OD ≈ 13.5 mm | Routine |
| 7 | Print legibility | Visual + rubbing | Marks legible | Routine |
| 8 | Mass per unit length | Weighing | ≈ 175 kg/km | Routine |
| 9 | Appearance | Visual | Smooth, no blisters | Routine |
| 10 | Packing | Visual | Coil, sealed ends, labelled | Routine |
| 11 | Shield coverage | Unwrap + count | ≥ 80% (≈ 85%) | Type |
| 12 | Heat aging test | 7 days at 100 °C | Retention ≥ 70% | Type |
| 13 | Cold bend test | -15 °C, 4 h mandrel | No cracking | Type |
| 14 | Jacket tensile test | Universal tester | Meets GB/T 9330 min. | Type |
| 15 | Flame retardancy | IEC 60332-1 | Self-extinguish | Type |
| 16 | Shielding effectiveness | Triaxial / open-field | ≥ 60 dB at 30–1000 MHz | Type |
Cable Cross Section Structure

| RVVP 4×2.5 mm² — Cross-Section Construction Diagram (Schematic) | |||||
| Layered build-up: pure copper Class 5 conductors (4 cores) → PVC insulation → inner PVC sheath → pure copper braid shield → PVC outer jacket · 300/500 V shielded power+control cable · motor power circuits / small transformer supply / power distribution + control · EMI/RFI protection · -15~+70 °C | |||||
| No. | Layer | Material / Construction | Nominal Thickness (mm) | Diameter (mm) | Function / Remarks |
| 1 | Conductor (×4) | Pure annealed copper, Class 5 flexible — 50 × 0.25 mm strands per core | — | ≈ 2.0 (per core) | Power + control; R ≤ 7.41 Ω/km; bare pure copper for high conductivity |
| 2 | Insulation (per core) | PVC compound (Type SP), extruded over each conductor, colour-coded | ≈ 0.8 | ≈ 3.6 (per insulated core) | Electrical insulation; 300/500 V rated; colour-coded for power/control identification |
| 3 | Inner sheath | PVC compound, extruded over the four laid-up cores, round filler | ≈ 0.8 | ≈ 10.6 (before braid) | Round and bed the quad core lay; mechanical protection; bedding for braid |
| 4 | Braid shield | Pure copper wire braid, ≈ 85% coverage, laid over inner sheath | ≈ 0.5 (effective) | ≈ 11.7 | EMI/RFI shielding; low transfer impedance for power + control circuits |
| 5 | Outer jacket | PVC compound (Type ST), black or grey, extruded over braid | ≈ 1.1 | ≈ 13.5 (finished) | Outer mechanical protection; oil-, abrasion-resistant; printed markings |
| Key Dimensions & Properties (expanded) | |||||
| Finished cable diameter | ≈ 13.5 | mm | 4-core shielded power+control cable (est.) | ||
| Approximate cable mass | ≈ 175 | kg/km | Pure Cu + PVC + braid build-up | ||
| Nominal voltage rating | 300/500 | V | Power / control / signal | ||
| Max continuous conductor temp. | 70 | °C | Normal service | ||
| Min. ambient / installation temp. | -15 | °C | Fixed installation | ||
| DC resistance @ 20 °C | ≤ 7.41 | Ω/km | Class 5 pure copper, GB/T 3956 | ||
| Core count × cross-section | 4 × 2.5 | mm² | 4 cores, quad formation | ||
| Shield coverage | ≈ 85 | % | Pure copper braid | ||
| Insulation resistance | ≥ 20 | MΩ·km | PVC at 20 °C | ||
| Test voltage (AC) | 2000 V AC / 5 min | — | Routine withstand test | ||
| Flame retardancy | IEC 60332-1 | — | Single vertical flame | ||
| Shielding effectiveness | ≈ 60–70 | dB | At 30–1000 MHz | ||
| Jacket colour | Black / grey / custom | — | Standard: black | ||
| Mass per 100 m | ≈ 17.5 | kg/100 m | For drum loading | ||
| Reference standard | GB/T 9330 / IEC 60227 / UL 2464 | — | Harmonized control cable | ||
| Schematic — not to exact scale. Finished Ø ≈ 13.5 mm and weight ≈ 175 kg/km from cross-referenced industry samples; conductor stranding 50/0.25 mm per core, 4-core quad formation, and braid coverage ≈ 85%. Pure copper (not tinned) for maximum conductivity. Est. values confirmed against factory type certificate. | |||||
Construction Description
| Construction Description — RVVP 4×2.5 mm² | |||
| Layer-by-layer build-up narrative · 300/500 V shielded power+control cable · GB/T 9330 / IEC 60227 · pure annealed copper / PVC insulation / pure copper braid shield / PVC outer jacket | |||
| 1. Product Identity & Ratings | |||
| RVVP 4×2.5 is a 4-core shielded power+control cable rated 300/500 V. It uses pure annealed copper (not tinned) for both the conductor and braid, maximizing conductivity. The four 2.5 mm² cores are laid up in a quad formation and handle motor power circuits, small transformer supply, and power distribution with control. OD ≈ 13.5 mm, ≈ 175 kg/km. Max 70 °C, -15 to +70 °C. For dry indoor use; specify tinned variant for damp/outdoor. | |||
| 2. Pure Copper Conductor (×4) | |||
| Each 2.5 mm² core is stranded from 50 pure annealed copper wires of 0.25 mm in a Class 5 flexible lay-up. Pure copper (bare, not tinned) delivers the highest conductivity: DC resistance ≤ 7.41 Ω/km at 20 °C — roughly 44% lower than 1.5 mm², making it suitable for motor power and transformer supply. The 50-wire stranding keeps the cable flexible for panel dressing. | |||
| 3. PVC Insulation | |||
| Each conductor receives a 0.8 mm Type SP PVC extrusion, colour-coded for power/control identification — typically red/black/blue/green-yellow. The thicker 0.8 mm wall provides extra dielectric margin for power circuits. Insulation resistance ≥ 20 MΩ·km at 20 °C. | |||
| 4. Inner Sheath + Braid Shield | |||
| The four insulated cores are laid up in a quad formation with round fillers to keep the cable round, then bedded with a 0.8 mm PVC inner sheath. Over this, a pure copper braid is woven at ≈ 85% coverage. The braid provides EMI/RFI shielding for power circuits and sensitive signals, diverting interference to ground through the shield drain. | |||
| 5. Outer PVC Jacket | |||
| A 1.1 mm Type ST PVC jacket completes the build, yielding an OD of ≈ 13.5 mm — a substantial step up from the 1.5 mm² version to match the larger power-grade core. The jacket is oil- and abrasion-resistant, flame-retardant per IEC 60332-1, and printed with product type, cross-section, voltage, metre mark and manufacturer. For drag-chain duty, specify RVVSP variant. |
8. Factory Advantages
Pure annealed copper conductor at 50×0.25 mm stranding delivers maximum conductivity with Class 5 flexibility. Lower DC resistance (7.41 vs 13.3 Ω/km) supports motor power and transformer supply. 0.8 mm insulation and 1.1 mm jacket provide robust dielectric and mechanical protection. Pure copper braid at ≈ 85% coverage provides low transfer impedance. 4-core quad formation combines power, control, signal and ground in one cable. Colour-coded cores prevent wiring errors. 100% routine electrical QA on every reel. Cut-to-length on coils with sealed ends. Full traceability with MTC and certification support for industrial machinery tenders.

9. Packaging, Storage & Logistics
Cut to customer-specified length on export-grade drums (for larger cross-sections), with both ends heat-sealed to prevent moisture ingress. Drums wrapped in waterproof film and corrugated cardboard, labelled with product type, core count, cross-section, length, weight, production date and reel number. Standard lengths 100/200/500 m. Store dry indoor, -10 to +40 °C, below 75% RH, away from direct sunlight and chemical solvents. FOB Shanghai/Nanjing/Qingdao; CIF and DAP available. Sample lead time 5–7 days; bulk production 15–25 days.

10. Procurement Specification
State cable designation "RVVP 4×2.5 pure copper", required length per drum, and core colour preference (e.g. red/black/blue/green-yellow for power/control). Request the routine AC withstand test record (2000 V) and shield coverage certificate for the specific batch. Note that this is a pure copper (bare) power+control variant for dry indoor use — for damp or outdoor applications, specify the tinned copper variant. Specify any regional certification requirements (UL 2464, CE, etc.) at order time. Payment: 30% T/T deposit, balance against B/L copy. Documents: MTC, ROHS/REACH, COO, commercial invoice, packing list.
11. Cable Industry FAQ
Q1: Why choose 2.5 mm² over 1.5 mm²? Lower DC resistance (7.41 vs 13.3 Ω/km), higher ampacity (16–22 A vs 10–13 A), and enough current for small motor power and transformer supply.
Q2: Can it power small motors? Yes — the 2.5 mm² core can carry 16–22 A, enough for small 0.5–2.2 kW motors, while the other three cores handle control, signal and ground.
Q3: How long can the motor power run be? At 230 V and 20 A load, voltage drop is ≈ 1.48 V per 100 m — suitable for runs up to 40 m with acceptable voltage loss.
Q4: What is the voltage rating? 300/500 V, suitable for low-voltage power and control circuits.
Q5: Why pure copper instead of tinned? Bare pure copper has higher conductivity than tinned copper, ideal for power and control circuits where every ohm matters.
Q6: Is it suitable for outdoor use? No — limited UV resistance and bare copper oxidize in humidity. Use indoors or in UV-protected conduits.
Q7: How do you ground the shield? Connect braid to earth at one end (or both ends per system design) using a shield gland or drain wire.
Q8: What is the bending radius? ≥ 6×OD ≈ 81 mm for fixed; 12× for moving applications.
Q9: What is the temperature range? -15 to +70 °C continuous.
Q10: What proof ships? Routine AC test record (2000 V) + shield coverage certificate + MTC.
Q11: When should I step up to 4×4.0? For larger motors (3–5 kW), longer runs (50+ m), or higher current loads (25+ A), step up to RVVP 4×4.0 mm².