logo
Anhui Tongdu International Trade Co., Ltd.
Online Service

Online Service

Contact Person
+86 19056002718
WeChat QR Code
Follow Us
Search Results For:

"power distribution pvc cable sheath"

- 90 Items Found
Quality Class 2 x 25mm2 2 Cores Cable Flame Retardant Copper Cable Xlpe Insulation Pvc Sheath factory

Class 2 x 25mm2 2 Cores Cable Flame Retardant Copper Cable Xlpe Insulation Pvc Sheath

ZR-YJV 2*25mm² Flame Retardant Copper Cable,0.6/1kV XLPE Insulation PVC Sheath for Power Distribution Cable Designation & Meaning Code Meaning ZC Flame retardant C— IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 2×25 mm² Two cores, 25 mm² copper conductor each ...

Quality 8.2 – 8.6mm 25mm2 5 core armoured cable sheathed flexible  For Indoor Power Distribution Systems factory

8.2 – 8.6mm 25mm2 5 core armoured cable sheathed flexible For Indoor Power Distribution Systems

5 Core 25mm² ZR-YJV Flame Retardant Copper Cable for Indoor Power Distribution Systems Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer ...

Quality 3×120mm2+1×70mm2 4 Cores Cable Power Distribution Flame Retardant XLPE Insulated Copper factory

3×120mm2+1×70mm2 4 Cores Cable Power Distribution Flame Retardant XLPE Insulated Copper

Power Distribution Cable ZR-YJV 3×120mm²+1×70mm², Flame Retardant XLPE Insulated Copper Wire Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer ...

Quality Building Power Distribution 2 Core Power Cable Braided Flex Oxygen Free Copper factory

Building Power Distribution 2 Core Power Cable Braided Flex Oxygen Free Copper

ZR-YJV 2*10mm² Flame Retardant 2 Core Power Cable,0.6/1kV Oxygen-Free Copper,XLPE Insulation PVC Sheath for Building Power Distribution Code Mean:ZR-Flame Retardant,YJ-XLPE Insulation,V-PVC Outer Sheathed. ZR-YJV 2×10 mm² — Technical Description 1. Product Class. The ZR-YJV 2×10 is a two-core flame...

Quality 2 Core 0.75mm2 Flexible PVC Cable RVV 2x0.75mm2 For Equipment Internal Wiring factory

2 Core 0.75mm2 Flexible PVC Cable RVV 2x0.75mm2 For Equipment Internal Wiring

2 Core 0.75mm² Flexible PVC Cable RVV-2*0.75mm² for Equipment Internal Wiring Cable Designation & Meaning Code Meaning RVV R = Flexible copper conductor (Class 5), V = PVC insulation, V = PVC sheath 300/500 V Rated voltage U₀/U = 300/500 V; Uₘ = 500 V 2×0.75 mm² Two flexible cores, each 0.75 mm² ...

Quality Low Voltage 2 Cores Cable 2 X 10mm2 Stranded Copper Fire Resistant PVC Insulated Sheathed factory

Low Voltage 2 Cores Cable 2 X 10mm2 Stranded Copper Fire Resistant PVC Insulated Sheathed

Low Voltage Power Cable 0.6/1kv YJV-2*10mm² Stranded Copper XLPE Insulation Fire-Resistant PVC Outer Sheath Cable Designation & Meaning Code Meaning ZC Flame retardant C — IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 2×10 mm² Two cores, 10 mm² copper ...

Quality 0.6/1kV 3 Cores Cable 3x16mm2 Stranded Copper Conductor XLPE Insulation PVC Outer Sheath factory

0.6/1kV 3 Cores Cable 3x16mm2 Stranded Copper Conductor XLPE Insulation PVC Outer Sheath

0.6/1kV ZC-YJV 3x16mm² Stranded Copper Conductor XLPE Insulation PVC Outer Sheath Low Voltage Power Cable Technical Datasheet — ZC-YJV 0.6/1 kV 1×16 mm² 1. Cable Designation & Meaning Code Meaning ZC​ Flame retardant, Class C (bundled combustion test) YJ​ XLPE (cross-linked polyethylene) insulation ...

Quality ZR-YJV 4 Core Electrical Cable 4x185mm2 Flame Retardant Copper Power Distribution factory

ZR-YJV 4 Core Electrical Cable 4x185mm2 Flame Retardant Copper Power Distribution

ZR-YJV 4*185mm² Flame Retardant 4 Core Copper Power Distribution Cable Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×185 mm² Four cores of 185 mm² copper conductor each (3 phase + 1 neutral, ...

Quality ZR-YJV 4×50mm² 0.6/1kV Flame Retardant Copper Cable, XLPE Insulation for Building Power Distribution factory

ZR-YJV 4×50mm² 0.6/1kV Flame Retardant Copper Cable, XLPE Insulation for Building Power Distribution

ZR-YJV 4×50mm² 0.6/1kV Flame Retardant Copper Cable, XLPE Insulation for Building Power Distribution Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×50 mm² Four equal cores of 50 mm² copper ...

Prev 1 2 3 4 5 Next