3×120mm2+1×70mm2 4 Cores Cable Power Distribution Flame Retardant XLPE Insulated Copper

3×120mm2+1×70mm2 4 Cores Cable Power Distribution Flame Retardant XLPE Insulated Copper

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
ZR-YJV 3×120mm²+1×70mm²

Trading Properties

moq
1 Meter
payment method
L/C,T/T
supply capacity
10000 meters per month

Product Summary

Power Distribution Cable ZR-YJV 3×120mm²+1×70mm², Flame Retardant XLPE Insulated Copper Wire Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer ...

Product Details

Highlight:

IEC 60228 4 Cores Cable

,

annealed copper 4 Cores Cable

,

Power Distribution Cable Insulated

Phase conductor (×3):
Bare Annealed Copper, Class 2 Stranded, 37×∅2.03 Mm, Conductor Ø ≈ 14.2–15.0 Mm Depending On Compaction
Neutral conductor (×1):
Bare Annealed Copper, Class 2 Stranded, 19×∅2.14 Mm, Conductor Ø ≈ 10.7–11.2 Mm Depending On Compaction
Phase conductor nominal area:
120 Mm²
Neutral conductor nominal area:
70 Mm²
Number of cores:
4 (3+1)
Phase conductor construction:
Class 2, 37×∅2.03 Mm,IEC 60228 / GB/T 3956
Neutral conductor construction:
Class 2, 19×∅2.14 Mm,IEC 60228 / GB/T 3956
Phase conductor diameter (approx.):
14.2–15.0 Mm
Neutral conductor diameter (approx.):
10.7–11.2 Mm
Insulation (×4):
XLPE
Phase insulation thickness:
1.2 Mm (120 Mm² Class)
Neutral insulation thickness:
1.1 Mm (70 Mm² Class)
Diameter over phase insulated core:
16.6–17.4 Mm
Diameter over neutral insulated core:
12.9–13.4 Mm
Filler / binder:
FR PP Filler + FR Tape
Outer sheath:
Flame-retardant PVC (ZR Grade)
Sheath thickness:
1.8 Mm (GB/T 12706 Multi-core 95–150 Mm² Range)
Overall cable diameter:
31.0 – 37.0 Mm
Design outer diameter:
≈ 33.5 Mm
Approx. weight:
1550 – 1950 Kg/km
Design weight:
≈ 1710 Kg/km
Cable shape:
Round

Product Description

Power Distribution Cable ZR-YJV 3×120mm²+1×70mm², Flame Retardant XLPE Insulated Copper Wire


Cable Designation & Meaning


Code

Meaning

ZR

Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC).

YJ

XLPE (cross-linked polyethylene) insulation

V

PVC outer sheath — flame-retardant grade, contains halogen (Cl)

0.6/1 kV

Rated voltage U₀/U = 600/1000 V; Uₘ = 1.2 kV

3×120+1×70 mm²

Three phase cores of 120 mm² copper + one reduced neutral core of 70 mm² copper


3×120mm2+1×70mm2 4 Cores Cable Power Distribution Flame Retardant XLPE Insulated Copper

ZC-YJV 3×120+1×70 mm² — LV Flame-Retardant 3+1 Power Cable — Specification

1. Overview & Ratings. ZC-YJV 3×120+1×70 is a heavy 3+1 LV power cable rated 0.6/1 kV (Um 1.2), 90 °C working, ZC class C flame-retardant heavy PVC sheath: three 120 mm² compacted copper phase cores plus one 70 mm² compacted neutral, thick dry-cured XLPE, unarmored (armor optional). OD ≈ 32 mm, ≈ 5200 kg/km (est.), ≈ 300 A per phase free air at 30 °C (est.). Scope: 380/400 V main risers, plant feeders and high-current distribution — not 950°C fire duty.


2. Construction Stack (Inner → Outer, expanded).


Layer / Feature Build Function
Conductor L1/L2/L3 3×120 compacted Cu, Class 2, ≈37 strands Phases, R ≤0.253 Ω/km
Conductor N 1×70 compacted Cu, Class 2, ≈19 strands Large neutral, R ≤0.268 Ω/km
Strand compaction Concentric layers rolled compact per core Round heavy bundles, clean lug entry
XLPE insulation (phases) Dry-cured PE, ≈2.2 mm Thick 90°C phase dielectric
XLPE insulation (neutral) Dry-cured PE, ≈1.8 mm Thick neutral dielectric
Core identification L1/L2/L3/N color code Phase sequence + neutral
3+1 core laying 3 large phases around neutral Stable heavy round bundle
Heavy PVC ZC sheath Class C, ≈2.2 mm overall Binds bundle, self-extinguishes
Jacket print Continuous type/size/voltage/length On-site readable spec


3. Electrical Characteristics. Phase R ≤ 0.253 Ω/km, neutral R ≤ 0.268 Ω/km @20 °C. Test 3.5 kV AC / 5 min; ≈ 300 A per phase (est., air 30 °C); short-circuit ≈ 12 kA / 1 s (est.); 50/60 Hz; unscreened; low-loss XLPE; high stable insulation resistance.

Insulation & Sheath Data

Property

Value

Insulation material

XLPE (cross-linked polyethylene)

Outer sheath material

PVC (ST₂)

Long-term service temp.

90 °C (continuous)

Max. conductor temp. (normal)

90 °C

Short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Test voltage AC (5 min)

3.5 kV

Dielectric strength

≥ 20 kV/mm

Volume resistivity @20 °C

≥ 1×10¹⁴ Ω·cm

Shield

None as standard (can be added)

Electrical Parameters

Parameter

Value

Note

Rated voltage U₀/U

0.6 / 1 kV

GB/T 12706.1 / IEC 60502-1

Max. system voltage

1.2 kV AC

—

Test voltage AC (5 min)

3.5 kV

Routine test

DC resistance @20 °C (phase)

≤ 0.153 Ω/km per core

GB/T 3956 Class 2 Cu max (120 mm²)

DC resistance @20 °C (neutral)

≤ 0.268 Ω/km per core

GB/T 3956 Class 2 Cu max (70 mm²)

AC resistance @90 °C (est., phase)

≈ 0.196 Ω/km per core

—

AC resistance @90 °C (est., neutral)

≈ 0.344 Ω/km per core

—

Current rating in air (30 °C)

3-phase: 290 A​

3×120+1×70, touching, in free air

Current rating in tray (30 °C)

3-phase: 320 A​

3×120+1×70, spaced 2×OD

Current rating buried in ground (20 °C, thermal resistivity 1.2 K·m/W)

3-phase: 305 A​

direct buried

Current rating in conduit (30 °C)

3-phase: 260 A​

—

Short-circuit current (1 s, Cu, 250 °C, phase)

≈ 13.3 kA (13,300 A) per core

—

Short-circuit current (1 s, Cu, 250 °C, neutral)

≈ 7.8 kA (7,800 A) per core

—

Capacitance (core-to-sheath, approx.)

≈ 0.21 µF/km

XLPE

Inductive reactance (approx.)

≈ 0.09 Ω/km

at 50 Hz

Frequency

50/60 Hz AC

—


Reference values: 3×120+1×70 at 290 A three-phase, 400 V → max load ≈ 174 kW​ (cos φ = 0.8). Suitable for large three-phase distribution with reduced neutral, heavy motors, and main building feeders.


4. Thermal & Flame. 90 °C continuous, 250 °C short-time; ZC class C self-extinguishing — flame retardancy, not 950°C integrity; withstands repeated 0~90°C cycles; indoor; UV-grade jacket optional.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

90 °C (continuous)

Max. short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Min. installation ambient temp.

0 °C (below 0 °C requires preheating)

Service ambient range

−20 °C to +90 °C

Flexing temp. range

0 °C to +90 °C

Fire Performance (ZC-YJV — Flame Retardant C)

Property

Value / Requirement

Flame retardant

GB/T 18380.12 / IEC 60332-1-2​ (single cable, self-extinguishing)

Flame retardant class

Class C​ (ZC) per GB/T 19666

Halogen content

Contains halogen (PVC sheath)

Smoke density

Not low-smoke (PVC)

Corrosivity

Corrosive (PVC)

Toxicity

Toxic fumes when burned (PVC)

EMI shielding

None (no metallic screen/armour)


5. Installation Practice & Handling. 120 mm² phase lugs, 70 mm² neutral lug, large glands to 32 mm OD, hydraulic crimp/torque per table; bend ≥ 15×OD ≈ 480 mm with rollers; strong derating in bundles/ducts; keep the 3+1 bundle round; continuity, phase sequence, neutral + insulation after pulling.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 15 × OD → ≈ 600 mm at Ø40.0 mm

four-core unarmoured

Max. pulling tension (phase)

1,800 N per core (120 mm² × 15 N/mm²)

Cu conductor limit

Max. pulling tension (neutral)

1,050 N per core (70 mm² × 15 N/mm²)

Cu conductor limit

Direct burial

Suitable (with sand bedding)

—

Surface mounting

Heavy-duty cable tray, ladder, cleats

—

Conduit ID

≥ 80 mm

—

Fixing

heavy-duty cleats, cable ties

—

Impact resistance

Moderate

—

Water resistance

Good (PVC sheath)

—

UV resistance

Fair (PVC degrades outdoors, use UV-resistant PVC or conduit)

—

Flex life

Fair (Class 2 stranded, large conductor)

fixed installation

Termination note

Heavy-duty compression lugs or mechanical connectors

—


6. Typical Service Applications. 380/400 V incoming-to-main-board risers and horizontal plant feeders, large motor group supplies, high-current distribution mains in factories, substations and large commercial buildings.

3×120mm2+1×70mm2 4 Cores Cable Power Distribution Flame Retardant XLPE Insulated Copper


7. Testing & QA Regime (16 items). Routine: phase DC resistance (120), neutral DC resistance (70), 3.5 kV withstand, insulation resistance, continuity, thick sheath/phase/neutral insulation thickness, dimensional check, strand construction, eccentricity, print legibility, mass. Type: ZC flame test, short-circuit rating, sheath mechanical.


Cable Parameters


ZC-YJV 3×120+1×70 mm² — LV Flame-Retardant 3+1 Power Cable — Full Parameter Sheet 
3×120 Cu phase / 1×70 Cu neutral · XLPE / PVC ZC · 0.6/1 kV · ≈32 mm · 3-phase + neutral for 380/400 V main riser, plant feeder and high-current distribution
Parameter Value Unit Remarks / Standard
01 · Identification
Cable type ZC-YJV — Cu/XLPE/PVC, flame-retardant class C — ZC-YJV denotes a copper conductor with cross-linked polyethylene insulation and a PVC outer sheath; ZC marks a class C flame-retardant PVC compound that self-extinguishes after the ignition source is removed.
Rated voltage (U0/U) 0.6/1 kV 0.6 kV phase-to-earth (U0) and 1 kV phase-to-phase (U) rating defines a general low-voltage cable suited to 380/400 V heavy distribution.
Maximum operating voltage (Um) 1.2 kV The 1.2 kV maximum system voltage is the continuous upper phase-to-earth limit the XLPE insulation may withstand in normal service.
Core configuration 3×120 phase + 1×70 neutral (3+1) — Three 120 mm² compacted copper phase cores around one 70 mm² compacted neutral core, laid 3+1 for main three-phase loads with a large proportioned neutral.
Conductor material Compacted stranded annealed copper — Soft annealed copper strands are layer-compacted into round bundles: 120 mm² on phases, 70 mm² on the neutral, for heavy lug entry.
Insulation XLPE cross-linked polyethylene — Chemically cross-linked polyethylene bonds into a heat-resistant dielectric retaining properties at the 90 °C operating temperature.
Sheath PVC, flame-retardant class C (ZC) — A heavy overall PVC jacket binds the 3+1 bundle and carries the class C flame-retardant formulation; deep forest emerald finish.
Flame retardancy ZC class C (self-extinguishing, not fire-rated) — On removal of a flame the cable stops propagating fire; this is flame retardancy, not 950 °C/180 min circuit-integrity fire resistance.
Suitable for Fixed indoor tray, riser, duct, 3-phase+N main — Designed for fixed three-phase-plus-neutral main risers and plant feeders serving large distribution boards.
Application 380V main riser / plant heavy feeder — Typically runs three phases plus neutral from the incoming panel to main distribution boards and large motor groups.
Application note Not for 950°C circuit-integrity fire duty — Do not substitute this ZC cable for a mineral-insulated or fire-resistant circuit; it cannot maintain live integrity under sustained fire.
02 · Conductors
Phase cores count / area 3 × 120 mm² Three 120 mm² phase conductors carry the three phases of a heavy 400 V main or plant feeder load.
Neutral core count / area 1 × 70 mm² One 70 mm² large proportioned neutral returns unbalanced and harmonic current on mixed and non-linear main loads.
Conductor type Compacted stranded Cu, Class 2 — Class 2 stranded compacted construction gives fixed-wiring conductors that round into stable bundles for heavy lug termination.
DC resistance (120 phase) @ 20°C ≤ 0.253 Ω/km Maximum permitted DC resistance of a 120 mm² phase copper conductor at 20 °C.
DC resistance (70 neutral) @ 20°C ≤ 0.268 Ω/km Maximum permitted DC resistance of a 70 mm² neutral copper conductor at 20 °C; neutral drop on long risers.
Stranding Layer-compacted concentric bundle — Concentric layers of strands are compacted radially per core to reduce gaps, tighten the bundle and present a clean round heavy-lug entry.
Strands (nom., est.) 120 ≈37 / 70 ≈19 — Approximate strand counts: about 37 compacted strands in a 120 mm² core and about 19 in the 70 mm² core; exact count follows the standard.
Surface Bare copper; tinned optional — Bare copper suits most indoor use; optional tinned plating improves corrosion resistance in damp or chemically mild sites.
Core identification L1/L2/L3 phase + N neutral by color — Phases and neutral are color-coded so phase sequence and neutral match at the main board or large motor terminal.
Nominal area tolerance Within conductor class 2 band — Actual cross-sectional area and strand geometry stay inside the class 2 tolerance band rather than a solid bare count.
03 · Insulation
Insulation material XLPE (cross-linked polyethylene) — Cross-linked PE delivers a higher continuous temperature rating and lower dielectric loss than PVC insulation for the same size.
Insulation thickness (phase 120, nom.) ≈ 2.2 mm Thick nominal radial insulation wall on each 120 mm² phase core; gauged to withstand the 3.5 kV routine test.
Insulation thickness (neutral 70, nom.) ≈ 1.8 mm Thick wall on the 70 mm² neutral core, gauged for the routine withstand test.
Working conductor temp. 90 °C Maximum continuous conductor temperature under rated current without shortening insulation life.
Short-circuit temp. 250 °C Peak conductor temperature the insulation may survive for a short fault duration (seconds) before damage occurs.
Insulation resistance High and stable MΩ·km XLPE keeps a high, stable insulation resistance over life, supporting reliable earth-fault detection on main feeders.
Color L1/L2/L3/N color on request — Insulation colors are matched to local 3-phase convention or supplied natural with printed marking.
Cure type Chemical / dry-cured XLPE — A controlled cross-linking cure locks the polymer network so the insulation stays elastic rather than melting under heat.
04 · Sheath & Flame Retardancy
Sheath material PVC, flame-retardant ZC — The heavy class C PVC outer jacket blends a flame-suppressing formulation while keeping a smooth, printable surface.
Sheath thickness (nom.) ≈ 2.2 mm Thick nominal overall jacket wall sized to shield the four large cores from abrasion, mechanical handling and duct damage.
Finished outer diameter ≈ 32 mm Overall 3+1 heavy finished diameter used to size large ducts, trunking and glands.
Flame behavior Self-extinguishing, class C — After the test flame is removed the sample extinguishes without propagating; it is not 950°C fire-rated.
Sheath color Deep forest emerald (black/gray on request) — Standard deep forest emerald; black or dark gray jackets are supplied for industrial aesthetics on request.
Surface finish Smooth, continuous print — A smooth heavy jacket carries a continuous printed line of type, size, voltage, ZC class and meter length along its length.
05 · Electrical
Rated voltage (U0/U) 0.6/1 kV Low-voltage rating matching 380/400 V heavy distribution systems.
Max voltage (Um) 1.2 kV Continuous upper system voltage for phase-to-earth insulation stress.
Nominal current (per 120 phase, est.) ≈ 300 A Approximate ampacity of a single 120 mm² phase core in free air at 30 °C; reduce strongly for bundling, duct fill and high ambient.
Test voltage (AC) 3.5 kV / 5 min — Routine dielectric withstand applied between each conductor and sheath for five minutes without breakdown.
Insulation resistance High, XLPE MΩ·km Measured after conditioning; confirms no void, crack or contamination in the thick cured insulation.
Short-circuit current (120 phase, 1s, est.) ≈ 12 kA Approximate 1-second copper short-time withstand on the 120 mm² phase core; main feeder fault duty.
Frequency 50 / 60 Hz Compatible with both 50 Hz and 60 Hz three-phase power systems.
Dielectric XLPE, low loss — Low dielectric loss keeps heating down under continuous main feeder and large motor load.
06 · Thermal & Environment
Normal conductor temp. 90 °C Sustained operating temperature the thick XLPE insulation is rated for under full load.
Installed ambient 0 ~ +40 °C Recommended continuous ambient around the cable; high rooms and crowded trays require ampacity derating.
Min install temp. 0 °C Avoid cold bending below 0 °C where the thick PVC jacket and insulation may stiffen and crack.
Burning Self-extinguishing, ZC class C — Class C vertical flame test behavior: flame stops once the external burner is removed.
Outdoor / UV Indoor preferred; UV-grade jacket optional — Standard PVC degrades under prolonged direct sun; specify UV-stabilized jacket for exposed outdoor risers.
Oil / chemicals Resistant to common oils; check aggressive media — Withstands typical machine oils; verify against specific solvents or acid fumes before use.
Temperature cycle Withstands repeated 0~90°C duty — The thick insulation and jacket survive repeated heating/cooling cycles without cracking or delamination.
07 · Mechanical & Construction
Min bending radius (fixed) ≥ 15 × OD ≈ 480 mm Fixed-installation minimum bend radius for the heavy 3+1 cable; tight bends risk insulation and jacket damage.
Flexibility Stranded, handled with rollers — Compacted strands remain manageable but large cores require rollers, supports and lifting equipment on site.
Shielding / Armor None / unarmored (armor optional) — No copper braid screen and no armor as standard; add steel-tape or wire armor where ground crushing or EMI exists.
Cable weight per km (est.) ≈ 5200 kg/km Heavy mass per kilometer used for structural tray loading and large drum sizing.
Circularity 3+1 core bundle, stable heavy OD — Three large phase cores plus one neutral lay into a round bundle so the finished OD stays consistent.
Tensile / elongation Heavy jacket meets PVC grade — Thick sheath tensile strength and elongation satisfy the PVC compound grade for rugged pulling.
08 · Factory Advantages
High-current 3+1 build 3×120 phases with 1×70 neutral for main feed — Large phase and neutral handle heavy balanced and non-linear main currents.
Thick stable XLPE cure Even cross-linking on thick insulation keeps the 90°C dielectric consistent — Controlled cure prevents soft spots in thick insulation under sustained main load.
Heavy dosed ZC compound Thick flame-retardant PVC self-extinguishes to class C — Dosed flame inhibitors protect cable rooms and main wiring spaces.
Length-on-demand Cut to exact riser/feeder meter, sealed ends — Custom cut lengths match the measured vertical riser and horizontal feeder route.
Batch resistance log Phase R (120) and neutral R (70) logged against lot — Both phase and neutral resistances are recorded against batch ID for full traceability.
Continuous print line Type, size, ZC, voltage and length along heavy jacket — Clear continuous marking lets installers read the spec on thick, long cables.
Phase-color option L1/L2/L3/N insulation colors matched to convention — Pre-colored phases and neutral remove wiring guesswork at main board terminals.
Heavy drum pack Large wooden drum with sealed ends and lifting cleats — Heavy main cable wound on industrial drums suitable for winch pulling.
Certified QA pack Routine + type test record shipped per batch — A complete QA packet supports buyer audit, inspection and commissioning sign-off.
09 · Installation
Laying Main tray, riser, duct, 3-phase+N — Route on rated heavy trays or vertical risers; keep the 3+1 bundle round and bending above 15×OD.
Connectors 120 mm² phase lugs, 70 mm² neutral lug — Crimp matched heavy 120 mm² lugs on phases and a 70 mm² lug on the neutral; select large glands sized to 32 mm OD.
Bend radius ≥ 15×OD ≈ 480 mm — Maintain the large minimum radius around riser bends to prevent insulation cold-working.
Parallel runs Strong derating in bundles and ducts — Adjacent heavy cores share heat; apply bundle derating before sizing the main breaker.
Site test Continuity + insulation post-laying — After pulling, verify three-phase continuity, neutral, phase sequence and insulation resistance.
Termination Strip, hydraulic crimp lug, torque per table — Strip thick insulation without nicking strands, use a hydraulic press on each lug, and torque per the lug table.
10 · Packing & Applications
Supply length Custom / heavy wooden drum m Cut to the measured main riser/feeder length on a heavy drum.
Length tolerance Per trade standard for cut lengths — Cut-length tolerance follows the applicable trade standard rather than a fixed meter promise.
Reel type Large wooden drum — Industrial drum for heavy main lengths; sealed ends prevent moisture ingress.
Surface marking ZC-YJV, 3×120+1×70, 0.6/1kV, ZC, length — Heavy jacket prints type, 3+1 core size, voltage, flame class and cumulative meter length.
Typical use Main riser, plant feeder, large motor group — Runs three phases plus neutral to main distribution boards and heavy motor groups.
Storage Dry indoor on drum supports, avoid UV — Store the drum horizontally on timber supports, dry and shaded, avoiding direct sunlight.


Cable Test Parameters

Test Parameters — ZC-YJV 3×120+1×70 LV Flame-Retardant 3+1 Cable
No. Test Item Test Condition / Method Requirement Type
1 Phase DC resistance 20 °C, each L1/L2/L3 (120 mm²) 120 ≤0.253 Ω/km Routine
2 Neutral DC resistance 20 °C, N (70 mm²) 70 ≤0.268 Ω/km Routine
3 Voltage test (AC) 3.5 kV AC, 5 min, core-to-sheath No breakdown Routine
4 Insulation resistance XLPE, 20°C, per core High & stable Routine
5 Continuity Each core L1/L2/L3/N Continuous Routine
6 Flame retardancy Class C vertical test Self-extinguish Type
7 Sheath thickness Micrometer, cross-section Nominal ≥2.2 mm Routine
8 Phase insulation thickness Micrometer, 120 mm² cores Nominal ≥2.2 mm Routine
9 Neutral insulation thickness Micrometer, 70 mm² core Nominal ≥1.8 mm Routine
10 Dimensional check Caliper, overall OD OD ≈ 32 mm Routine
11 Conductor construction Visual / strand count per core Class 2 compacted Routine
12 Short-circuit rating Calculated / type 12 kA / 1 s (phase) Type
13 Insulation eccentric test Cross-section measure per core Within tolerance Routine
14 Printing legibility Visual Marking readable Routine
15 Mass per unit length Weigh / calculate ≈ 5200 kg/km Routine
16 Sheath mechanical Tensile / elongation check Meets PVC grade Type


Cable Cross Section Structure


3×120mm2+1×70mm2 4 Cores Cable Power Distribution Flame Retardant XLPE Insulated Copper

ZC-YJV 3×120+1×70 — 3+1 Cross-Section Construction Diagram 
3×120 phase Cu + 1×70 neutral Cu / XLPE insulation / PVC ZC sheath · 0.6/1 kV · ZC class C · ≈32 mm · main riser, plant feeder & high-current distribution
No. Layer / Feature Material / Construction Nominal Thickness (mm) Diameter (mm) Detailed Function / Remarks
1 Conductor L1 — phase 1×120 compacted Cu, Class 2, ≈37 strands — ≈ 13.4 Phase 1 core, DC R ≤0.253 Ω/km @20°C; main feeder current.
2 Conductor L2 — phase 1×120 compacted Cu, Class 2, ≈37 strands — ≈ 13.4 Phase 2 core, same size/resistance for balanced impedance.
3 Conductor L3 — phase 1×120 compacted Cu, Class 2, ≈37 strands — ≈ 13.4 Phase 3 core, same spec; color-coded for phase sequence.
4 Conductor N — neutral 1×70 compacted Cu, Class 2, ≈19 strands — ≈ 10.2 Large neutral, DC R ≤0.268 Ω/km; returns unbalanced/harmonic current.
5 Strand compaction Concentric layers rolled compact per core — — Radial compaction closes gaps for round heavy bundles and clean lug entry.
6 XLPE insulation (phases) Dry-cured cross-linked PE, ≈2.2 mm ≈ 2.2 ≈ 17.8 90°C thick dielectric on each 120 mm² phase core, low loss.
7 XLPE insulation (neutral) Dry-cured cross-linked PE, ≈1.8 mm ≈ 1.8 ≈ 13.8 Thick neutral insulation; N distinguished by color from phases.
8 3+1 laying & PVC ZC sheath 3 phases + 1 neutral, heavy class C jacket ≈ 2.2 ≈ 32 Three large phases around the neutral; heavy jacket binds bundle and self-extinguishes.
9 Jacket print Continuous type/size/voltage/length line — — Marking: ZC-YJV, 3×120+1×70, 0.6/1kV, ZC, cumulative length.
Key Dimensions, Electrical & Mechanical Properties (expanded)
Finished cable diameter ≈ 32 mm Heavy 3+1 overall OD for large ducts and glands.
Approx. cable mass (est.) ≈ 5200 kg/km Heavy main feeder cable; drum-loaded.
Nominal voltage rating 0.6/1 kV Matches 380/400 V systems.
Max voltage (Um) 1.2 kV Phase-to-earth continuous upper limit.
Normal conductor temp. 90 °C Continuous load temperature of XLPE.
Short-circuit temp. 250 °C Short-time fault peak before insulation damage.
DC resistance (120 phase) ≤ 0.253 Ω/km Per phase core @20°C.
DC resistance (70 neutral) ≤ 0.268 Ω/km Neutral core @20°C.
Nominal phase current (est.) ≈ 300 A Per 120 phase core, free air 30°C; strong derating bundled.
Short-circuit rating (1s, est.) ≈ 12 kA 120 phase, main feeder fault duty.
Flame retardancy ZC class C, self-extinguishing — Not 950°C fire-rated.
Min bending radius (fixed) ≥ 15 × OD ≈ 480 mm Heavy 3+1 riser/feeder bend radius.
Frequency 50 / 60 Hz Compatible with both power systems.
Insulation resistance High & stable MΩ·km XLPE; supports earth-fault detection.
Dielectric loss Low — XLPE keeps heating down on main load.
Temperature cycle 0~90°C repeated — Survives heating/cooling without cracking.
Sheath mechanical Heavy jacket meets PVC grade — Tensile/elongation checked at type test.
Pack choice Large wooden drum — Industrial drum with lifting cleats.
Core configuration 3×120 + 1×70 (3+1) — Three large phases + large neutral.
Application Main riser, plant feeder, large motor group — 380/400 V heavy 3-phase+N power.
Schematic — not to exact scale. OD ≈32 mm, weight ≈5200 kg/km, phase ampacity ≈300 A free air at 30°C and ≈12 kA/1s are (est.) from cross-referenced industry samples. ZC-YJV 3×120+1×70 serves 380/400 V main risers, plant feeders and large motor groups; ZC class C self-extinguishes but is not 950°C fire-rated. Estimated values require confirmation against the factory test certificate for the specific batch.


Cable Construction Description


Construction Description — ZC-YJV 3×120+1×70 LV flame-retardant 3+1 cable
3×120 phase Cu + 1×70 neutral Cu / XLPE insulation / PVC ZC sheath · 0.6/1 kV · ZC class C · 90°C · ≈32 mm · main riser, plant feeder & high-current distribution
1. Product Identity & Ratings
ZC-YJV 3×120+1×70 rated 0.6/1 kV (Um 1.2), 90°C working, ZC class C; three 120 mm² phases plus one 70 mm² neutral in 3+1 lay. OD ≈32 mm, ≈5200 kg/km (est.), ≈300 A per phase free air at 30°C (est.), large wooden drum. It is a fixed heavy main feeder cable, not a flexible cord and not a 950°C fire-rated circuit.
2. Copper Conductors (3×120 phases + 1×70 neutral)
Three 120 mm² compacted Class 2 Cu phase cores (L1/L2/L3), R ≤0.253 Ω/km @20°C, plus one 70 mm² compacted Cu neutral, R ≤0.268 Ω/km @20°C; large neutral for non-linear and harmonic main loads; tinned plating optional; phase-color insulation on request.
3. Strand Compaction & 3+1 Bundle
Concentric strands are rolled compact per core to close gaps and give clean heavy-lug entry; the three large phase cores lay around the neutral in a controlled 3+1 arrangement to hold a round heavy bundle before sheathing.
4. XLPE Insulation
Dry-cured cross-linked PE ≈2.2 mm on phases and ≈1.8 mm on the neutral; stable 90°C dielectric, low dielectric loss, high and stable insulation resistance; short-circuit peak 250°C; phases and neutral distinguished by color.
5. Core Identification
L1/L2/L3 phases and the N neutral are identified by insulation color so phase sequence and neutral match at the main board or large motor terminal; colors can be supplied to local 3-phase convention.
6. PVC ZC Sheath
Heavy flame-retardant PVC ≈2.2 mm overall, self-extinguishing class C; deep forest emerald standard (black/gray on request); smooth printable surface; binds the heavy 3+1 bundle and shields from abrasion and duct damage.
7. Electrical Characteristics
0.6/1 kV, Um 1.2; phase R ≤0.253, neutral R ≤0.268 Ω/km; routine 3.5 kV AC/5 min; ≈300 A per phase (est., air 30°C); short-circuit ≈12 kA/1s (est.); 50/60 Hz; unscreened; low-loss XLPE.
8. Factory Advantages
• High-current 3+1 build (3×120 phases + 1×70 neutral).  • Thick stable XLPE cure.  • Heavy dosed ZC self-extinguish.  • Length-on-demand.  • Phase + neutral resistance log.  • Continuous clear print.  • Phase-color option.  • Heavy drum pack.  • Certified QA pack.
9. Site Handling & Installation
• Bend 15×OD (≈480 mm) with rollers.  • 120 mm² phase lugs, 70 mm² neutral lug, large glands, hydraulic crimp, torque per table.  • Strong derating in bundles/ducts.  • Keep 3+1 bundle round.  • Continuity, phase sequence, neutral + insulation after pulling.
10. Typical Service Applications
380/400 V incoming-to-main-board risers and horizontal plant feeders, large motor group supplies, high-current distribution mains in factories, substations and large commercial buildings.
11. Testing & QA
16-item regime: routine phase DC resistance (120), neutral DC resistance (70), 3.5 kV withstand, insulation resistance, continuity, thick sheath/phase/neutral insulation thickness, dimensional check, strand construction, eccentricity, print legibility, mass; type ZC flame, short-circuit, sheath mechanical.
12. Packaging, Storage & Notes
Cut to measured riser/feeder length on a large wooden drum with sealed ends; continuous marking; store dry indoor on drum supports, shaded, avoid direct UV. Est. OD/weight/ampacity/short-circuit confirmed against the factory certificate; ZC is flame retardant, not 950°C fire-rated.


8. Factory Advantages.

  • High-current 3+1 build — 3×120 phases with 1×70 neutral for main feed.
  • Thick stable XLPE cure — even cross-linking on thick insulation keeps the 90°C dielectric consistent.
  • Heavy dosed ZC compound — thick flame-retardant PVC self-extinguishes to class C.
  • Length-on-demand — exact riser/feeder meter, sealed ends.
  • Phase + neutral resistance log — both recorded against lot number.
  • Continuous print line — type, size, ZC, voltage and length along heavy jacket.
  • Phase-color option — L1/L2/L3/N colors matched to convention.
  • Heavy drum pack — large wooden drum with lifting cleats.
  • Certified QA pack — routine + type test record per batch.

3×120mm2+1×70mm2 4 Cores Cable Power Distribution Flame Retardant XLPE Insulated Copper

9. Packaging, Storage & Logistics. Cut to measured riser/feeder length on a large wooden drum with sealed ends; continuous marking; store dry indoor on drum supports, shaded, avoid direct UV.

3×120mm2+1×70mm2 4 Cores Cable Power Distribution Flame Retardant XLPE Insulated Copper


10. Procurement Specification. State "ZC-YJV 3×120+1×70", length, class C, phase colors, armor if required, heavy drum; note flame retardant not fire-rated; request phase + neutral resistance log and 16-item QA record. Est. values confirmed against the factory certificate.


11. Cable Industry FAQ.

  • Q1: How does 3×120+1×70 differ from 2×10? Three large phases plus a large neutral (3+1) vs a twin L+N pair; vastly larger (120 vs 10 mm²), much thicker (32 vs 10.0 mm), far heavier (5200 vs 320 kg/km), far higher current (300 vs 55 A), far lower resistance (0.253 vs 1.91 Ω/km). It runs 400 V main feeders, not 230 V lighting drops.
  • Q2: Why a 70 mm² neutral? Heavy main loads often carry harmonics and unbalance; the large neutral keeps neutral heating and drop under control.
  • Q3: Is ZC fire-resistant? No. Class C self-extinguishes; it does not hold live at 950°C/180min.
  • Q4: DC resistance values? Phase 120 ≤0.253 Ω/km; neutral 70 ≤0.268 Ω/km at 20°C.
  • Q5: Armor or screen? Unarmored standard; add steel-tape/wire armor for ground-crushing ducts and braid screen for EMI.
  • Q6: Current per phase? ≈ 300 A (est.) free air 30°C; derate strongly in crowded trays and ducts.
  • Q7: Bending? ≥ 480 mm (15×OD); use rollers and winch on this heavy cable.
  • Q8: Connectors? 120 mm² phase lugs, 70 mm² neutral lug, hydraulic press, large gland to 32 mm OD.
  • Q9: Indoor or outdoor? Indoor preferred; UV-grade jacket for exposed risers.
  • Q10: Packing? Large wooden drum with sealed ends and lifting cleats.
  • Q11: What proof ships? Phase + neutral resistance log + 16-test record; est. values confirmed against certificate.