3×120mm2+1×70mm2 4 Cores Cable Power Distribution Flame Retardant XLPE Insulated Copper
Product Summary
Product Details
IEC 60228 4 Cores Cable
,annealed copper 4 Cores Cable
,Power Distribution Cable Insulated
Product Description
Power Distribution Cable ZR-YJV 3×120mm²+1×70mm², Flame Retardant XLPE Insulated Copper Wire
Cable Designation & Meaning
|
Code |
Meaning |
|---|---|
|
ZR |
Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). |
|
YJ |
XLPE (cross-linked polyethylene) insulation |
|
V |
PVC outer sheath — flame-retardant grade, contains halogen (Cl) |
|
0.6/1 kV |
Rated voltage U₀/U = 600/1000 V; Uₘ = 1.2 kV |
|
3×120+1×70 mm² |
Three phase cores of 120 mm² copper + one reduced neutral core of 70 mm² copper |

ZC-YJV 3×120+1×70 mm² — LV Flame-Retardant 3+1 Power Cable — Specification
1. Overview & Ratings. ZC-YJV 3×120+1×70 is a heavy 3+1 LV power cable rated 0.6/1 kV (Um 1.2), 90 °C working, ZC class C flame-retardant heavy PVC sheath: three 120 mm² compacted copper phase cores plus one 70 mm² compacted neutral, thick dry-cured XLPE, unarmored (armor optional). OD ≈ 32 mm, ≈ 5200 kg/km (est.), ≈ 300 A per phase free air at 30 °C (est.). Scope: 380/400 V main risers, plant feeders and high-current distribution — not 950°C fire duty.
2. Construction Stack (Inner → Outer, expanded).
| Layer / Feature | Build | Function |
|---|---|---|
| Conductor L1/L2/L3 | 3×120 compacted Cu, Class 2, ≈37 strands | Phases, R ≤0.253 Ω/km |
| Conductor N | 1×70 compacted Cu, Class 2, ≈19 strands | Large neutral, R ≤0.268 Ω/km |
| Strand compaction | Concentric layers rolled compact per core | Round heavy bundles, clean lug entry |
| XLPE insulation (phases) | Dry-cured PE, ≈2.2 mm | Thick 90°C phase dielectric |
| XLPE insulation (neutral) | Dry-cured PE, ≈1.8 mm | Thick neutral dielectric |
| Core identification | L1/L2/L3/N color code | Phase sequence + neutral |
| 3+1 core laying | 3 large phases around neutral | Stable heavy round bundle |
| Heavy PVC ZC sheath | Class C, ≈2.2 mm overall | Binds bundle, self-extinguishes |
| Jacket print | Continuous type/size/voltage/length | On-site readable spec |
3. Electrical Characteristics. Phase R ≤ 0.253 Ω/km, neutral R ≤ 0.268 Ω/km @20 °C. Test 3.5 kV AC / 5 min; ≈ 300 A per phase (est., air 30 °C); short-circuit ≈ 12 kA / 1 s (est.); 50/60 Hz; unscreened; low-loss XLPE; high stable insulation resistance.
Insulation & Sheath Data
|
Property |
Value |
|---|---|
|
Insulation material |
XLPE (cross-linked polyethylene) |
|
Outer sheath material |
PVC (ST₂) |
|
Long-term service temp. |
90 °C (continuous) |
|
Max. conductor temp. (normal) |
90 °C |
|
Short-circuit temp. (≤5 s) |
250 °C |
|
Emergency overload temp. |
130 °C (≤1 h) |
|
Test voltage AC (5 min) |
3.5 kV |
|
Dielectric strength |
≥ 20 kV/mm |
|
Volume resistivity @20 °C |
≥ 1×10¹⁴ Ω·cm |
|
Shield |
None as standard (can be added) |
Electrical Parameters
|
Parameter |
Value |
Note |
|---|---|---|
|
Rated voltage U₀/U |
0.6 / 1 kV |
GB/T 12706.1 / IEC 60502-1 |
|
Max. system voltage |
1.2 kV AC |
— |
|
Test voltage AC (5 min) |
3.5 kV |
Routine test |
|
DC resistance @20 °C (phase) |
≤ 0.153 Ω/km per core |
GB/T 3956 Class 2 Cu max (120 mm²) |
|
DC resistance @20 °C (neutral) |
≤ 0.268 Ω/km per core |
GB/T 3956 Class 2 Cu max (70 mm²) |
|
AC resistance @90 °C (est., phase) |
≈ 0.196 Ω/km per core |
— |
|
AC resistance @90 °C (est., neutral) |
≈ 0.344 Ω/km per core |
— |
|
Current rating in air (30 °C) |
3-phase: 290 A |
3×120+1×70, touching, in free air |
|
Current rating in tray (30 °C) |
3-phase: 320 A |
3×120+1×70, spaced 2×OD |
|
Current rating buried in ground (20 °C, thermal resistivity 1.2 K·m/W) |
3-phase: 305 A |
direct buried |
|
Current rating in conduit (30 °C) |
3-phase: 260 A |
— |
|
Short-circuit current (1 s, Cu, 250 °C, phase) |
≈ 13.3 kA (13,300 A) per core |
— |
|
Short-circuit current (1 s, Cu, 250 °C, neutral) |
≈ 7.8 kA (7,800 A) per core |
— |
|
Capacitance (core-to-sheath, approx.) |
≈ 0.21 µF/km |
XLPE |
|
Inductive reactance (approx.) |
≈ 0.09 Ω/km |
at 50 Hz |
|
Frequency |
50/60 Hz AC |
— |
Reference values: 3×120+1×70 at 290 A three-phase, 400 V → max load ≈ 174 kW (cos φ = 0.8). Suitable for large three-phase distribution with reduced neutral, heavy motors, and main building feeders.
4. Thermal & Flame. 90 °C continuous, 250 °C short-time; ZC class C self-extinguishing — flame retardancy, not 950°C integrity; withstands repeated 0~90°C cycles; indoor; UV-grade jacket optional.
Temperature Characteristics
|
Property |
Value |
|---|---|
|
Max. conductor operating temp. |
90 °C (continuous) |
|
Max. short-circuit temp. (≤5 s) |
250 °C |
|
Emergency overload temp. |
130 °C (≤1 h) |
|
Min. installation ambient temp. |
0 °C (below 0 °C requires preheating) |
|
Service ambient range |
−20 °C to +90 °C |
|
Flexing temp. range |
0 °C to +90 °C |
Fire Performance (ZC-YJV — Flame Retardant C)
|
Property |
Value / Requirement |
|---|---|
|
Flame retardant |
GB/T 18380.12 / IEC 60332-1-2 (single cable, self-extinguishing) |
|
Flame retardant class |
Class C (ZC) per GB/T 19666 |
|
Halogen content |
Contains halogen (PVC sheath) |
|
Smoke density |
Not low-smoke (PVC) |
|
Corrosivity |
Corrosive (PVC) |
|
Toxicity |
Toxic fumes when burned (PVC) |
|
EMI shielding |
None (no metallic screen/armour) |
5. Installation Practice & Handling. 120 mm² phase lugs, 70 mm² neutral lug, large glands to 32 mm OD, hydraulic crimp/torque per table; bend ≥ 15×OD ≈ 480 mm with rollers; strong derating in bundles/ducts; keep the 3+1 bundle round; continuity, phase sequence, neutral + insulation after pulling.
Mechanical & Installation Parameters
|
Parameter |
Value |
Remarks |
|---|---|---|
|
Minimum bending radius |
≥ 15 × OD → ≈ 600 mm at Ø40.0 mm |
four-core unarmoured |
|
Max. pulling tension (phase) |
1,800 N per core (120 mm² × 15 N/mm²) |
Cu conductor limit |
|
Max. pulling tension (neutral) |
1,050 N per core (70 mm² × 15 N/mm²) |
Cu conductor limit |
|
Direct burial |
Suitable (with sand bedding) |
— |
|
Surface mounting |
Heavy-duty cable tray, ladder, cleats |
— |
|
Conduit ID |
≥ 80 mm |
— |
|
Fixing |
heavy-duty cleats, cable ties |
— |
|
Impact resistance |
Moderate |
— |
|
Water resistance |
Good (PVC sheath) |
— |
|
UV resistance |
Fair (PVC degrades outdoors, use UV-resistant PVC or conduit) |
— |
|
Flex life |
Fair (Class 2 stranded, large conductor) |
fixed installation |
|
Termination note |
Heavy-duty compression lugs or mechanical connectors |
— |
6. Typical Service Applications. 380/400 V incoming-to-main-board risers and horizontal plant feeders, large motor group supplies, high-current distribution mains in factories, substations and large commercial buildings.

7. Testing & QA Regime (16 items). Routine: phase DC resistance (120), neutral DC resistance (70), 3.5 kV withstand, insulation resistance, continuity, thick sheath/phase/neutral insulation thickness, dimensional check, strand construction, eccentricity, print legibility, mass. Type: ZC flame test, short-circuit rating, sheath mechanical.
Cable Parameters
| ZC-YJV 3×120+1×70 mm² — LV Flame-Retardant 3+1 Power Cable — Full Parameter Sheet | |||
| 3×120 Cu phase / 1×70 Cu neutral · XLPE / PVC ZC · 0.6/1 kV · ≈32 mm · 3-phase + neutral for 380/400 V main riser, plant feeder and high-current distribution | |||
| Parameter | Value | Unit | Remarks / Standard |
| 01 · Identification | |||
| Cable type | ZC-YJV — Cu/XLPE/PVC, flame-retardant class C | — | ZC-YJV denotes a copper conductor with cross-linked polyethylene insulation and a PVC outer sheath; ZC marks a class C flame-retardant PVC compound that self-extinguishes after the ignition source is removed. |
| Rated voltage (U0/U) | 0.6/1 | kV | 0.6 kV phase-to-earth (U0) and 1 kV phase-to-phase (U) rating defines a general low-voltage cable suited to 380/400 V heavy distribution. |
| Maximum operating voltage (Um) | 1.2 | kV | The 1.2 kV maximum system voltage is the continuous upper phase-to-earth limit the XLPE insulation may withstand in normal service. |
| Core configuration | 3×120 phase + 1×70 neutral (3+1) | — | Three 120 mm² compacted copper phase cores around one 70 mm² compacted neutral core, laid 3+1 for main three-phase loads with a large proportioned neutral. |
| Conductor material | Compacted stranded annealed copper | — | Soft annealed copper strands are layer-compacted into round bundles: 120 mm² on phases, 70 mm² on the neutral, for heavy lug entry. |
| Insulation | XLPE cross-linked polyethylene | — | Chemically cross-linked polyethylene bonds into a heat-resistant dielectric retaining properties at the 90 °C operating temperature. |
| Sheath | PVC, flame-retardant class C (ZC) | — | A heavy overall PVC jacket binds the 3+1 bundle and carries the class C flame-retardant formulation; deep forest emerald finish. |
| Flame retardancy | ZC class C (self-extinguishing, not fire-rated) | — | On removal of a flame the cable stops propagating fire; this is flame retardancy, not 950 °C/180 min circuit-integrity fire resistance. |
| Suitable for | Fixed indoor tray, riser, duct, 3-phase+N main | — | Designed for fixed three-phase-plus-neutral main risers and plant feeders serving large distribution boards. |
| Application | 380V main riser / plant heavy feeder | — | Typically runs three phases plus neutral from the incoming panel to main distribution boards and large motor groups. |
| Application note | Not for 950°C circuit-integrity fire duty | — | Do not substitute this ZC cable for a mineral-insulated or fire-resistant circuit; it cannot maintain live integrity under sustained fire. |
| 02 · Conductors | |||
| Phase cores count / area | 3 × 120 | mm² | Three 120 mm² phase conductors carry the three phases of a heavy 400 V main or plant feeder load. |
| Neutral core count / area | 1 × 70 | mm² | One 70 mm² large proportioned neutral returns unbalanced and harmonic current on mixed and non-linear main loads. |
| Conductor type | Compacted stranded Cu, Class 2 | — | Class 2 stranded compacted construction gives fixed-wiring conductors that round into stable bundles for heavy lug termination. |
| DC resistance (120 phase) @ 20°C | ≤ 0.253 | Ω/km | Maximum permitted DC resistance of a 120 mm² phase copper conductor at 20 °C. |
| DC resistance (70 neutral) @ 20°C | ≤ 0.268 | Ω/km | Maximum permitted DC resistance of a 70 mm² neutral copper conductor at 20 °C; neutral drop on long risers. |
| Stranding | Layer-compacted concentric bundle | — | Concentric layers of strands are compacted radially per core to reduce gaps, tighten the bundle and present a clean round heavy-lug entry. |
| Strands (nom., est.) | 120 ≈37 / 70 ≈19 | — | Approximate strand counts: about 37 compacted strands in a 120 mm² core and about 19 in the 70 mm² core; exact count follows the standard. |
| Surface | Bare copper; tinned optional | — | Bare copper suits most indoor use; optional tinned plating improves corrosion resistance in damp or chemically mild sites. |
| Core identification | L1/L2/L3 phase + N neutral by color | — | Phases and neutral are color-coded so phase sequence and neutral match at the main board or large motor terminal. |
| Nominal area tolerance | Within conductor class 2 band | — | Actual cross-sectional area and strand geometry stay inside the class 2 tolerance band rather than a solid bare count. |
| 03 · Insulation | |||
| Insulation material | XLPE (cross-linked polyethylene) | — | Cross-linked PE delivers a higher continuous temperature rating and lower dielectric loss than PVC insulation for the same size. |
| Insulation thickness (phase 120, nom.) | ≈ 2.2 | mm | Thick nominal radial insulation wall on each 120 mm² phase core; gauged to withstand the 3.5 kV routine test. |
| Insulation thickness (neutral 70, nom.) | ≈ 1.8 | mm | Thick wall on the 70 mm² neutral core, gauged for the routine withstand test. |
| Working conductor temp. | 90 | °C | Maximum continuous conductor temperature under rated current without shortening insulation life. |
| Short-circuit temp. | 250 | °C | Peak conductor temperature the insulation may survive for a short fault duration (seconds) before damage occurs. |
| Insulation resistance | High and stable | MΩ·km | XLPE keeps a high, stable insulation resistance over life, supporting reliable earth-fault detection on main feeders. |
| Color | L1/L2/L3/N color on request | — | Insulation colors are matched to local 3-phase convention or supplied natural with printed marking. |
| Cure type | Chemical / dry-cured XLPE | — | A controlled cross-linking cure locks the polymer network so the insulation stays elastic rather than melting under heat. |
| 04 · Sheath & Flame Retardancy | |||
| Sheath material | PVC, flame-retardant ZC | — | The heavy class C PVC outer jacket blends a flame-suppressing formulation while keeping a smooth, printable surface. |
| Sheath thickness (nom.) | ≈ 2.2 | mm | Thick nominal overall jacket wall sized to shield the four large cores from abrasion, mechanical handling and duct damage. |
| Finished outer diameter | ≈ 32 | mm | Overall 3+1 heavy finished diameter used to size large ducts, trunking and glands. |
| Flame behavior | Self-extinguishing, class C | — | After the test flame is removed the sample extinguishes without propagating; it is not 950°C fire-rated. |
| Sheath color | Deep forest emerald (black/gray on request) | — | Standard deep forest emerald; black or dark gray jackets are supplied for industrial aesthetics on request. |
| Surface finish | Smooth, continuous print | — | A smooth heavy jacket carries a continuous printed line of type, size, voltage, ZC class and meter length along its length. |
| 05 · Electrical | |||
| Rated voltage (U0/U) | 0.6/1 | kV | Low-voltage rating matching 380/400 V heavy distribution systems. |
| Max voltage (Um) | 1.2 | kV | Continuous upper system voltage for phase-to-earth insulation stress. |
| Nominal current (per 120 phase, est.) | ≈ 300 | A | Approximate ampacity of a single 120 mm² phase core in free air at 30 °C; reduce strongly for bundling, duct fill and high ambient. |
| Test voltage (AC) | 3.5 kV / 5 min | — | Routine dielectric withstand applied between each conductor and sheath for five minutes without breakdown. |
| Insulation resistance | High, XLPE | MΩ·km | Measured after conditioning; confirms no void, crack or contamination in the thick cured insulation. |
| Short-circuit current (120 phase, 1s, est.) | ≈ 12 | kA | Approximate 1-second copper short-time withstand on the 120 mm² phase core; main feeder fault duty. |
| Frequency | 50 / 60 | Hz | Compatible with both 50 Hz and 60 Hz three-phase power systems. |
| Dielectric | XLPE, low loss | — | Low dielectric loss keeps heating down under continuous main feeder and large motor load. |
| 06 · Thermal & Environment | |||
| Normal conductor temp. | 90 | °C | Sustained operating temperature the thick XLPE insulation is rated for under full load. |
| Installed ambient | 0 ~ +40 | °C | Recommended continuous ambient around the cable; high rooms and crowded trays require ampacity derating. |
| Min install temp. | 0 | °C | Avoid cold bending below 0 °C where the thick PVC jacket and insulation may stiffen and crack. |
| Burning | Self-extinguishing, ZC class C | — | Class C vertical flame test behavior: flame stops once the external burner is removed. |
| Outdoor / UV | Indoor preferred; UV-grade jacket optional | — | Standard PVC degrades under prolonged direct sun; specify UV-stabilized jacket for exposed outdoor risers. |
| Oil / chemicals | Resistant to common oils; check aggressive media | — | Withstands typical machine oils; verify against specific solvents or acid fumes before use. |
| Temperature cycle | Withstands repeated 0~90°C duty | — | The thick insulation and jacket survive repeated heating/cooling cycles without cracking or delamination. |
| 07 · Mechanical & Construction | |||
| Min bending radius (fixed) | ≥ 15 × OD ≈ 480 | mm | Fixed-installation minimum bend radius for the heavy 3+1 cable; tight bends risk insulation and jacket damage. |
| Flexibility | Stranded, handled with rollers | — | Compacted strands remain manageable but large cores require rollers, supports and lifting equipment on site. |
| Shielding / Armor | None / unarmored (armor optional) | — | No copper braid screen and no armor as standard; add steel-tape or wire armor where ground crushing or EMI exists. |
| Cable weight per km (est.) | ≈ 5200 | kg/km | Heavy mass per kilometer used for structural tray loading and large drum sizing. |
| Circularity | 3+1 core bundle, stable heavy OD | — | Three large phase cores plus one neutral lay into a round bundle so the finished OD stays consistent. |
| Tensile / elongation | Heavy jacket meets PVC grade | — | Thick sheath tensile strength and elongation satisfy the PVC compound grade for rugged pulling. |
| 08 · Factory Advantages | |||
| High-current 3+1 build | 3×120 phases with 1×70 neutral for main feed | — | Large phase and neutral handle heavy balanced and non-linear main currents. |
| Thick stable XLPE cure | Even cross-linking on thick insulation keeps the 90°C dielectric consistent | — | Controlled cure prevents soft spots in thick insulation under sustained main load. |
| Heavy dosed ZC compound | Thick flame-retardant PVC self-extinguishes to class C | — | Dosed flame inhibitors protect cable rooms and main wiring spaces. |
| Length-on-demand | Cut to exact riser/feeder meter, sealed ends | — | Custom cut lengths match the measured vertical riser and horizontal feeder route. |
| Batch resistance log | Phase R (120) and neutral R (70) logged against lot | — | Both phase and neutral resistances are recorded against batch ID for full traceability. |
| Continuous print line | Type, size, ZC, voltage and length along heavy jacket | — | Clear continuous marking lets installers read the spec on thick, long cables. |
| Phase-color option | L1/L2/L3/N insulation colors matched to convention | — | Pre-colored phases and neutral remove wiring guesswork at main board terminals. |
| Heavy drum pack | Large wooden drum with sealed ends and lifting cleats | — | Heavy main cable wound on industrial drums suitable for winch pulling. |
| Certified QA pack | Routine + type test record shipped per batch | — | A complete QA packet supports buyer audit, inspection and commissioning sign-off. |
| 09 · Installation | |||
| Laying | Main tray, riser, duct, 3-phase+N | — | Route on rated heavy trays or vertical risers; keep the 3+1 bundle round and bending above 15×OD. |
| Connectors | 120 mm² phase lugs, 70 mm² neutral lug | — | Crimp matched heavy 120 mm² lugs on phases and a 70 mm² lug on the neutral; select large glands sized to 32 mm OD. |
| Bend radius | ≥ 15×OD ≈ 480 mm | — | Maintain the large minimum radius around riser bends to prevent insulation cold-working. |
| Parallel runs | Strong derating in bundles and ducts | — | Adjacent heavy cores share heat; apply bundle derating before sizing the main breaker. |
| Site test | Continuity + insulation post-laying | — | After pulling, verify three-phase continuity, neutral, phase sequence and insulation resistance. |
| Termination | Strip, hydraulic crimp lug, torque per table | — | Strip thick insulation without nicking strands, use a hydraulic press on each lug, and torque per the lug table. |
| 10 · Packing & Applications | |||
| Supply length | Custom / heavy wooden drum | m | Cut to the measured main riser/feeder length on a heavy drum. |
| Length tolerance | Per trade standard for cut lengths | — | Cut-length tolerance follows the applicable trade standard rather than a fixed meter promise. |
| Reel type | Large wooden drum | — | Industrial drum for heavy main lengths; sealed ends prevent moisture ingress. |
| Surface marking | ZC-YJV, 3×120+1×70, 0.6/1kV, ZC, length | — | Heavy jacket prints type, 3+1 core size, voltage, flame class and cumulative meter length. |
| Typical use | Main riser, plant feeder, large motor group | — | Runs three phases plus neutral to main distribution boards and heavy motor groups. |
| Storage | Dry indoor on drum supports, avoid UV | — | Store the drum horizontally on timber supports, dry and shaded, avoiding direct sunlight. |
Cable Test Parameters
| Test Parameters — ZC-YJV 3×120+1×70 LV Flame-Retardant 3+1 Cable | ||||
| No. | Test Item | Test Condition / Method | Requirement | Type |
| 1 | Phase DC resistance | 20 °C, each L1/L2/L3 (120 mm²) | 120 ≤0.253 Ω/km | Routine |
| 2 | Neutral DC resistance | 20 °C, N (70 mm²) | 70 ≤0.268 Ω/km | Routine |
| 3 | Voltage test (AC) | 3.5 kV AC, 5 min, core-to-sheath | No breakdown | Routine |
| 4 | Insulation resistance | XLPE, 20°C, per core | High & stable | Routine |
| 5 | Continuity | Each core L1/L2/L3/N | Continuous | Routine |
| 6 | Flame retardancy | Class C vertical test | Self-extinguish | Type |
| 7 | Sheath thickness | Micrometer, cross-section | Nominal ≥2.2 mm | Routine |
| 8 | Phase insulation thickness | Micrometer, 120 mm² cores | Nominal ≥2.2 mm | Routine |
| 9 | Neutral insulation thickness | Micrometer, 70 mm² core | Nominal ≥1.8 mm | Routine |
| 10 | Dimensional check | Caliper, overall OD | OD ≈ 32 mm | Routine |
| 11 | Conductor construction | Visual / strand count per core | Class 2 compacted | Routine |
| 12 | Short-circuit rating | Calculated / type | 12 kA / 1 s (phase) | Type |
| 13 | Insulation eccentric test | Cross-section measure per core | Within tolerance | Routine |
| 14 | Printing legibility | Visual | Marking readable | Routine |
| 15 | Mass per unit length | Weigh / calculate | ≈ 5200 kg/km | Routine |
| 16 | Sheath mechanical | Tensile / elongation check | Meets PVC grade | Type |
Cable Cross Section Structure

| ZC-YJV 3×120+1×70 — 3+1 Cross-Section Construction Diagram | |||||
| 3×120 phase Cu + 1×70 neutral Cu / XLPE insulation / PVC ZC sheath · 0.6/1 kV · ZC class C · ≈32 mm · main riser, plant feeder & high-current distribution | |||||
| No. | Layer / Feature | Material / Construction | Nominal Thickness (mm) | Diameter (mm) | Detailed Function / Remarks |
| 1 | Conductor L1 — phase | 1×120 compacted Cu, Class 2, ≈37 strands | — | ≈ 13.4 | Phase 1 core, DC R ≤0.253 Ω/km @20°C; main feeder current. |
| 2 | Conductor L2 — phase | 1×120 compacted Cu, Class 2, ≈37 strands | — | ≈ 13.4 | Phase 2 core, same size/resistance for balanced impedance. |
| 3 | Conductor L3 — phase | 1×120 compacted Cu, Class 2, ≈37 strands | — | ≈ 13.4 | Phase 3 core, same spec; color-coded for phase sequence. |
| 4 | Conductor N — neutral | 1×70 compacted Cu, Class 2, ≈19 strands | — | ≈ 10.2 | Large neutral, DC R ≤0.268 Ω/km; returns unbalanced/harmonic current. |
| 5 | Strand compaction | Concentric layers rolled compact per core | — | — | Radial compaction closes gaps for round heavy bundles and clean lug entry. |
| 6 | XLPE insulation (phases) | Dry-cured cross-linked PE, ≈2.2 mm | ≈ 2.2 | ≈ 17.8 | 90°C thick dielectric on each 120 mm² phase core, low loss. |
| 7 | XLPE insulation (neutral) | Dry-cured cross-linked PE, ≈1.8 mm | ≈ 1.8 | ≈ 13.8 | Thick neutral insulation; N distinguished by color from phases. |
| 8 | 3+1 laying & PVC ZC sheath | 3 phases + 1 neutral, heavy class C jacket | ≈ 2.2 | ≈ 32 | Three large phases around the neutral; heavy jacket binds bundle and self-extinguishes. |
| 9 | Jacket print | Continuous type/size/voltage/length line | — | — | Marking: ZC-YJV, 3×120+1×70, 0.6/1kV, ZC, cumulative length. |
| Key Dimensions, Electrical & Mechanical Properties (expanded) | |||||
| Finished cable diameter | ≈ 32 | mm | Heavy 3+1 overall OD for large ducts and glands. | ||
| Approx. cable mass (est.) | ≈ 5200 | kg/km | Heavy main feeder cable; drum-loaded. | ||
| Nominal voltage rating | 0.6/1 | kV | Matches 380/400 V systems. | ||
| Max voltage (Um) | 1.2 | kV | Phase-to-earth continuous upper limit. | ||
| Normal conductor temp. | 90 | °C | Continuous load temperature of XLPE. | ||
| Short-circuit temp. | 250 | °C | Short-time fault peak before insulation damage. | ||
| DC resistance (120 phase) | ≤ 0.253 | Ω/km | Per phase core @20°C. | ||
| DC resistance (70 neutral) | ≤ 0.268 | Ω/km | Neutral core @20°C. | ||
| Nominal phase current (est.) | ≈ 300 | A | Per 120 phase core, free air 30°C; strong derating bundled. | ||
| Short-circuit rating (1s, est.) | ≈ 12 | kA | 120 phase, main feeder fault duty. | ||
| Flame retardancy | ZC class C, self-extinguishing | — | Not 950°C fire-rated. | ||
| Min bending radius (fixed) | ≥ 15 × OD ≈ 480 | mm | Heavy 3+1 riser/feeder bend radius. | ||
| Frequency | 50 / 60 | Hz | Compatible with both power systems. | ||
| Insulation resistance | High & stable | MΩ·km | XLPE; supports earth-fault detection. | ||
| Dielectric loss | Low | — | XLPE keeps heating down on main load. | ||
| Temperature cycle | 0~90°C repeated | — | Survives heating/cooling without cracking. | ||
| Sheath mechanical | Heavy jacket meets PVC grade | — | Tensile/elongation checked at type test. | ||
| Pack choice | Large wooden drum | — | Industrial drum with lifting cleats. | ||
| Core configuration | 3×120 + 1×70 (3+1) | — | Three large phases + large neutral. | ||
| Application | Main riser, plant feeder, large motor group | — | 380/400 V heavy 3-phase+N power. | ||
| Schematic — not to exact scale. OD ≈32 mm, weight ≈5200 kg/km, phase ampacity ≈300 A free air at 30°C and ≈12 kA/1s are (est.) from cross-referenced industry samples. ZC-YJV 3×120+1×70 serves 380/400 V main risers, plant feeders and large motor groups; ZC class C self-extinguishes but is not 950°C fire-rated. Estimated values require confirmation against the factory test certificate for the specific batch. | |||||
Cable Construction Description
| Construction Description — ZC-YJV 3×120+1×70 LV flame-retardant 3+1 cable | |||
| 3×120 phase Cu + 1×70 neutral Cu / XLPE insulation / PVC ZC sheath · 0.6/1 kV · ZC class C · 90°C · ≈32 mm · main riser, plant feeder & high-current distribution | |||
| 1. Product Identity & Ratings | |||
| ZC-YJV 3×120+1×70 rated 0.6/1 kV (Um 1.2), 90°C working, ZC class C; three 120 mm² phases plus one 70 mm² neutral in 3+1 lay. OD ≈32 mm, ≈5200 kg/km (est.), ≈300 A per phase free air at 30°C (est.), large wooden drum. It is a fixed heavy main feeder cable, not a flexible cord and not a 950°C fire-rated circuit. | |||
| 2. Copper Conductors (3×120 phases + 1×70 neutral) | |||
| Three 120 mm² compacted Class 2 Cu phase cores (L1/L2/L3), R ≤0.253 Ω/km @20°C, plus one 70 mm² compacted Cu neutral, R ≤0.268 Ω/km @20°C; large neutral for non-linear and harmonic main loads; tinned plating optional; phase-color insulation on request. | |||
| 3. Strand Compaction & 3+1 Bundle | |||
| Concentric strands are rolled compact per core to close gaps and give clean heavy-lug entry; the three large phase cores lay around the neutral in a controlled 3+1 arrangement to hold a round heavy bundle before sheathing. | |||
| 4. XLPE Insulation | |||
| Dry-cured cross-linked PE ≈2.2 mm on phases and ≈1.8 mm on the neutral; stable 90°C dielectric, low dielectric loss, high and stable insulation resistance; short-circuit peak 250°C; phases and neutral distinguished by color. | |||
| 5. Core Identification | |||
| L1/L2/L3 phases and the N neutral are identified by insulation color so phase sequence and neutral match at the main board or large motor terminal; colors can be supplied to local 3-phase convention. | |||
| 6. PVC ZC Sheath | |||
| Heavy flame-retardant PVC ≈2.2 mm overall, self-extinguishing class C; deep forest emerald standard (black/gray on request); smooth printable surface; binds the heavy 3+1 bundle and shields from abrasion and duct damage. | |||
| 7. Electrical Characteristics | |||
| 0.6/1 kV, Um 1.2; phase R ≤0.253, neutral R ≤0.268 Ω/km; routine 3.5 kV AC/5 min; ≈300 A per phase (est., air 30°C); short-circuit ≈12 kA/1s (est.); 50/60 Hz; unscreened; low-loss XLPE. | |||
| 8. Factory Advantages | |||
| • High-current 3+1 build (3×120 phases + 1×70 neutral). • Thick stable XLPE cure. • Heavy dosed ZC self-extinguish. • Length-on-demand. • Phase + neutral resistance log. • Continuous clear print. • Phase-color option. • Heavy drum pack. • Certified QA pack. | |||
| 9. Site Handling & Installation | |||
| • Bend 15×OD (≈480 mm) with rollers. • 120 mm² phase lugs, 70 mm² neutral lug, large glands, hydraulic crimp, torque per table. • Strong derating in bundles/ducts. • Keep 3+1 bundle round. • Continuity, phase sequence, neutral + insulation after pulling. | |||
| 10. Typical Service Applications | |||
| 380/400 V incoming-to-main-board risers and horizontal plant feeders, large motor group supplies, high-current distribution mains in factories, substations and large commercial buildings. | |||
| 11. Testing & QA | |||
| 16-item regime: routine phase DC resistance (120), neutral DC resistance (70), 3.5 kV withstand, insulation resistance, continuity, thick sheath/phase/neutral insulation thickness, dimensional check, strand construction, eccentricity, print legibility, mass; type ZC flame, short-circuit, sheath mechanical. | |||
| 12. Packaging, Storage & Notes | |||
| Cut to measured riser/feeder length on a large wooden drum with sealed ends; continuous marking; store dry indoor on drum supports, shaded, avoid direct UV. Est. OD/weight/ampacity/short-circuit confirmed against the factory certificate; ZC is flame retardant, not 950°C fire-rated. |
8. Factory Advantages.
- High-current 3+1 build — 3×120 phases with 1×70 neutral for main feed.
- Thick stable XLPE cure — even cross-linking on thick insulation keeps the 90°C dielectric consistent.
- Heavy dosed ZC compound — thick flame-retardant PVC self-extinguishes to class C.
- Length-on-demand — exact riser/feeder meter, sealed ends.
- Phase + neutral resistance log — both recorded against lot number.
- Continuous print line — type, size, ZC, voltage and length along heavy jacket.
- Phase-color option — L1/L2/L3/N colors matched to convention.
- Heavy drum pack — large wooden drum with lifting cleats.
- Certified QA pack — routine + type test record per batch.

9. Packaging, Storage & Logistics. Cut to measured riser/feeder length on a large wooden drum with sealed ends; continuous marking; store dry indoor on drum supports, shaded, avoid direct UV.

10. Procurement Specification. State "ZC-YJV 3×120+1×70", length, class C, phase colors, armor if required, heavy drum; note flame retardant not fire-rated; request phase + neutral resistance log and 16-item QA record. Est. values confirmed against the factory certificate.
11. Cable Industry FAQ.
- Q1: How does 3×120+1×70 differ from 2×10? Three large phases plus a large neutral (3+1) vs a twin L+N pair; vastly larger (120 vs 10 mm²), much thicker (32 vs 10.0 mm), far heavier (5200 vs 320 kg/km), far higher current (300 vs 55 A), far lower resistance (0.253 vs 1.91 Ω/km). It runs 400 V main feeders, not 230 V lighting drops.
- Q2: Why a 70 mm² neutral? Heavy main loads often carry harmonics and unbalance; the large neutral keeps neutral heating and drop under control.
- Q3: Is ZC fire-resistant? No. Class C self-extinguishes; it does not hold live at 950°C/180min.
- Q4: DC resistance values? Phase 120 ≤0.253 Ω/km; neutral 70 ≤0.268 Ω/km at 20°C.
- Q5: Armor or screen? Unarmored standard; add steel-tape/wire armor for ground-crushing ducts and braid screen for EMI.
- Q6: Current per phase? ≈ 300 A (est.) free air 30°C; derate strongly in crowded trays and ducts.
- Q7: Bending? ≥ 480 mm (15×OD); use rollers and winch on this heavy cable.
- Q8: Connectors? 120 mm² phase lugs, 70 mm² neutral lug, hydraulic press, large gland to 32 mm OD.
- Q9: Indoor or outdoor? Indoor preferred; UV-grade jacket for exposed risers.
- Q10: Packing? Large wooden drum with sealed ends and lifting cleats.
- Q11: What proof ships? Phase + neutral resistance log + 16-test record; est. values confirmed against certificate.