Product Description
0.6/1kV ZC-YJV 3x16mm² Stranded Copper Conductor XLPE Insulation PVC Outer Sheath Low Voltage Power Cable
Technical Datasheet — ZC-YJV 0.6/1 kV 1×16 mm²
1. Cable Designation & Meaning
|
Code |
Meaning |
|---|---|
|
ZC |
Flame retardant, Class C (bundled combustion test) |
|
YJ |
XLPE (cross-linked polyethylene) insulation |
|
V |
PVC (polyvinyl chloride) outer sheath |
|
0.6/1 kV |
Rated voltage U₀/U = 600/1000 V; max. system voltage Uₘ = 1.2 kV |
|
1×16 mm² |
Single core, nominal copper conductor area 16 mm² |
|
Construction |
Unarmoured, non-screened, round cable |
2. Applicable Standards
- GB/T 12706.1-2020 (equivalent to IEC 60502-1) — Extruded insulation power cables ≤ 1 kV
- GB/T 3956 / IEC 60228 — Conductors (Class 2)
- GB/T 19666-2019 — Flame retardant & fire resistant cables
- GB/T 18380.3 — Bundled flame propagation test (Class C)
关键参数已核实,16mm² 有几个重要差异点必须先说明(与前面 120/185 大截面不同):
- 绝缘标称厚度 = 0.7 mm(GB/T 12706.1,10/16 mm² 档)——这是正确值.注:部分招标文件把 PVC/XLPE 分开规定,XLPE 16mm² 为 0.7 mm
- 护套标称厚度 = 1.4 mm(单芯 16mm²,1.5–35 mm² 档均取 1.4)
- 导体 = Class 2 绞合铜,7×∅1.70 mm(16mm² ≤35mm² 可实心/绞合,GB/T 3956 最少 7 根)
- 导体直流电阻 ≤1.15 Ω/km(20℃,GB/T 3956 Class 2)
- 外径 ≈ 9.3 mm,重量 ≈ 201–221 kg/km(多家样本一致,ZC-YJV 约 214)
- 载流量:空气中 ≈ 100–115 A(30℃单根单芯),直埋 ≈ 125 A(20℃)——注意:单芯 16mm² 直埋反而高于空气中(典型样本表值 125/99 铜)
下面交付完整英文数据表.
Technical Datasheet — ZC-YJV 0.6/1 kV 1×16 mm²
1. Cable Designation & Meaning
|
Code |
Meaning |
|---|---|
|
ZC |
Flame retardant, Class C (bundled combustion test) |
|
YJ |
XLPE (cross-linked polyethylene) insulation |
|
V |
PVC (polyvinyl chloride) outer sheath |
|
0.6/1 kV |
Rated voltage U₀/U = 600/1000 V; max. system voltage Uₘ = 1.2 kV |
|
1×16 mm² |
Single core, nominal copper conductor area 16 mm² |
|
Construction |
Unarmoured, non-screened, round cable |
2. Applicable Standards
- GB/T 12706.1-2020 (equivalent to IEC 60502-1) — Extruded insulation power cables ≤ 1 kV
- GB/T 3956 / IEC 60228 — Conductors (Class 2)
- GB/T 19666-2019 — Flame retardant & fire resistant cables
- GB/T 18380.3 — Bundled flame propagation test (Class C)
3. Product Components / Construction (inside → outside)
- Conductor — Bare annealed copper, Class 2 stranded (7×∅1.70 mm typical); compacted circular for single core
- Conductor screen — Not required for 0.6/1 kV Class 2; normally omitted
- Insulation — XLPE compound, extruded (black / red / blue etc. on request)
- Insulation thickness (nominal) — 0.7 mm (GB/T 12706.1, 10/16 mm² class)
- Filler / binder — Generally none for single-core; thin non-hygroscopic binder tape optional
- Outer sheath — Flame-retardant PVC compound (ZC grade)
- Sheath thickness (nominal) — 1.4 mm
- Sheath colour — Black (standard); other colours available
- Armour — None
- Metallic screen — None
4. Dimensional Data
|
Item |
Typical value |
Remarks |
|---|---|---|
|
Conductor nominal area |
16 mm² |
— |
|
Conductor construction |
Class 2, 7×∅1.70 mm (typical) |
min. 7 wires per GB/T 3956 |
|
Conductor diameter (approx.) |
5.0 mm |
|
|
Insulation nominal thickness |
0.7 mm |
|
|
Diameter over insulation (approx.) |
6.4 mm |
5.0 + 2×0.7 |
|
Sheath nominal thickness |
1.4 mm |
|
|
Overall cable diameter |
8.7 – 9.9 mm |
Typical 9.3 mm; range 8.7–9.9 across makers |
|
Approx. weight |
201 – 221 kg/km |
201 (EVER), 202 (gbt12706), 204 (Walsin), 210 (ZC-YJV structure table), 214 (ZC-YJV), 221.6 (JCCC) |
|
Cable shape |
Round |
— |


5. Insulation Data
- Material: XLPE (cross-linked polyethylene)
- Nominal thickness: 0.7 mm (GB/T 12706.1, 16 mm² at 0.6/1 kV)
- Long-term service temperature rating: 90 °C
- Short-circuit temperature rating (≤5 s): 250 °C
- Emergency overload temperature: 105–130 °C (limited duration, general XLPE practice)
- Dielectric strength: Pass 3.5 kV AC / 5 min routine test; 4.0 kV type test
- Volume resistivity @90 °C: ≥ 10¹² Ω·cm (typical XLPE)
- Insulation resistance: ≥ 100 MΩ·km @20 °C (500 V megger); constant R₀·L ≈ 3.67 MΩ·km @90 °C
6. Electrical Parameters
|
Parameter |
Value |
Source / Note |
|---|---|---|
|
Rated voltage U₀/U |
0.6 / 1 kV |
Uₘ = 1.2 kV |
|
Test voltage AC (5 min) |
3.5 kV |
Routine test (some makers 4.0 kV) |
|
Type-test voltage |
4.0 kV |
IEC 60502 practice |
|
DC resistance @20 °C (Class 2 Cu) |
≤ 1.15 Ω/km |
GB/T 3956 / IEC 60228 max |
|
AC resistance @90 °C (est.) |
≈ 1.50 Ω/km |
Copper temp. coefficient |
|
Recommended current rating — in air (30 °C, single circuit, single-core, 25 ℃ ref.) |
≈ 100–115 A |
100 (河南太平洋), 115 (金环宇单芯); typical design ≈ 105–115 A |
|
In air — per common sample table (25 ℃) |
125 A |
copper |
|
In air (40 ℃) |
≈ 105 A |
|
|
Direct buried / in soil (20 ℃) |
≈ 125 A |
125 (JCCC/河南太平洋); 99 (玖开 Al/Cu mixed note) |
|
Trefoil (air / ground) |
84 / 98 A |
reference, NYY type |
|
Flat (air / ground) |
87 / 101 A |
reference |
|
Short-circuit current capacity (1 s adiabatic, Cu, 250 °C) |
≈ 1.84 kA |
reference |
|
Inductance |
Trefoil ≈ 0.327 mH/km; Flat ≈ 0.374 mH/km |
reference |
|
Frequency |
50/60 Hz AC (DC usable) |
— |

7. Temperature Characteristics
- Max. conductor operating temperature (continuous): 90 °C
- Max. conductor temperature during short circuit (≤5 s): 250 °C
- Emergency overload temperature: 105 °C (limited duration)
- Min. ambient temperature during installation: 0 °C (below 0 °C requires pre-heating)
- Service ambient temperature range: −20 °C to +90 °C (sheath/environment)
- Flame retardant class: Category C, bundled flame test, self-extinguishing, limited flame spread per GB/T 19666
8. Mechanical & Installation Parameters
- Minimum bending radius (single-core unarmoured): ≥ 15 × overall diameter (single-core; some sources state 20D for GB/T 12706) → ≈ 140–150 mm at Ø9.3 mm
- Maximum pulling tension (copper conductor only): 50 N/mm² × 16 mm² = 800 N
- PVC sheath pulling limit: significantly lower — avoid direct sheath grip; use conductor pulling eye
- Direct burial: Allowed in non-aggressive soil; recommended sand bed + warning tape, depth ≥ 0.7 m, conduit under roads
- Magnetic conduit warning (AC single-core): Avoid magnetic steel pipe/conduit in AC circuits; use non-magnetic conduit or trefoil arrangement to prevent eddy-current heating
- Conduit fill: Conduit ID ≥ 1.5 × cable OD
- Elevation difference: No limitation for XLPE insulated cable
9. Material Specification Summary
- Conductor: Cu ≥ 99.9 % annealed, Class 2, 7×∅1.70 mm (typical), IEC 60228 / GB/T 3956
- Insulation: XLPE, 0.7 mm nom., rated 90 °C
- Sheath: PVC (black, flame-retardant ZC type), 1.4 mm nom.
- No armour, no metallic screen, no separate earth core
10. Scope of Application / Usage Range
The ZC-YJV 0.6/1 kV 1×16 mm² cable is intended for fixed installation in low-voltage power distribution & transmission systems up to 1.2 kV system voltage, where basic flame-retardant (Class C) performance is required but fire-survival (fire-resistant) function is not mandated.
Typical applicable locations:
- Indoor power distribution rooms, switchboards, distribution boxes, and final sub-circuits
- Cable trays, cable ducts, cable trenches & shafts in residential, commercial and public buildings
- Lighting branch circuits and small-to-medium power equipment feeders (16 mm² is a standard size for lighting/utility circuits)
- Fixed wiring in industrial plants, warehouses, and machinery feeders
- Direct buried routes in non-aggressive soil with low mechanical impact
- Street lighting, small PV/combiner and EV charger branch circuits (DC side requires polarity check)
- High-rise buildings, metro/station auxiliary power, general civil projects requiring ZC flame-retardant grade
Not suitable for:
- Heavy tensile / armour-protected routes → use YJV22 / ZC-YJV22
- Fire-survival emergency circuits → use NH-ZC-YJV
- Highly corrosive / hydrocarbon-rich environments without extra barrier
- Magnetic conduit AC single-core runs (eddy-current risk)
- Long high-current feeders where voltage drop / 105 A limit governs (upsize to 25 mm²+)

11. Packing
- Drum: Steel-wooden drum; common length 100–1000 m per drum (16 mm² flexible, long continuous lengths typical)
- HS code (China): 8544 4921 (LV power cable, PVC sheath)
Key engineering notes for 16 mm²
- Insulation is only 0.7 mm — the same as 1.5 mm². This is correct per GB/T 12706.1 (the 10/16 mm² class). Do not apply the 1.2/1.6 mm values from 120/185 mm².
- Sheath is 1.4 mm (not 1.5/1.7 mm) — single-core 1.5–35 mm² share this value .
- Conductor is 7×1.70 mm for stranded (Class 2); solid Class 1 is also permitted for 16 mm² ≤ 35 mm² .
- Design current: ≈ 100 A (air) / ≈ 115–125 A (buried) — always apply correction for grouping, ambient temperature, and conduit fill; for a 30 kW motor (≈54 A) at 200 m, 16 mm² gives voltage drop ≈ 2.4 V (well within 19 V limit) .
- ZC ≠ NH: ZC is flame-retardant only, not fire-survival. For emergency/life-safety circuits, use NH-ZC-YJV.