ZR-YJV 4*16mm² Fire Retardant Four Conductor Cable, 0.6/1kV, XLPE PVC Sheath for Indoor Power Wiring
ZR-YJV 4*16mm² Fire Retardant Four Conductor Cable, 0.6/1kV, XLPE PVC Sheath for Indoor Power Wiring Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×16 mm² Four equal cores of 16 mm² copper ...
Low Voltage 4 Cores Cable ZR-YJV 3×35mm2+1×16mm2 XLPE Cable
Low Voltage Flame Retardant ZR-YJV 3×35mm²+1×16mm² XLPE Cable for Mobile Power Distribution Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer ...
Armored XLPE High Voltage Power Cable 3 Core 25mm2 YJV22 Underground Power Cable
Armored XLPE Cable 3 Core 25mm² YJV22 8.7/10kV Underground Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...
Underground Distribution High Voltage Power Cable 3 Core 35mm2 YJV22 XLPE
Underground Distribution Cable 3 Core 35mm² YJV22 8.7/15kV Armored XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...
Primary Distribution Cable 3 Core 70mm² YJV22 8.7/10kV Armored XLPE
Primary Distribution Cable 3 Core 70mm² YJV22 8.7/10kV Armored XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV; ...
High Capacity MV Cable YJV22 3x95mm² 8.7/15kV Armored XLPE Power Cable
High Capacity MV Cable YJV22 3x95mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...
Ultra Heavy MV Cable YJV22 3x185mm² 8.7/15kV Armored XLPE Power Cable
Ultra Heavy MV Cable YJV22 3x185mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV...
Transport Hub Main Power Cable YJV22 3x240mm² 8.7/15kV Armored MV XLPE
Transport Hub Main Power Cable YJV22 3x240mm² 8.7/15kV Armored MV XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...
Super Heavy MV Cable YJV22 3x300mm² 8.7/15kV Armored XLPE Power Cable
Super Heavy MV Cable YJV22 3x300mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV...