Building Power Distribution 2 Core Power Cable Braided Flex Oxygen Free Copper

Building Power Distribution 2 Core Power Cable Braided Flex Oxygen Free Copper

Basic Properties

country of origin
China
brand name
TD
certificate
CE/ISO/CCC
product model
ZR-YJV 2*10mm²

Trading Properties

moq
100 meters
payment method
L/C,T/T
supply capacity
100000 meters per month

Product Summary

ZR-YJV 2*10mm² Flame Retardant 2 Core Power Cable,0.6/1kV Oxygen-Free Copper,XLPE Insulation PVC Sheath for Building Power Distribution Code Mean:ZR-Flame Retardant,YJ-XLPE Insulation,V-PVC Outer Sheathed. ZR-YJV 2×10 mm² — Technical Description 1. Product Class. The ZR-YJV 2×10 is a two-core flame...

Product Details

Highlight:

Power Distribution 2 core power cable

,

2 core power cable Oxygen Free

,

Copper 2 core braided flex

Conductor (×2):
Bare Annealed Copper, Class 2 Stranded, 7×∅1.35 Mm, Conductor Ø ≈ 4.0 Mm
Conductor nominal area (per core):
10 Mm²
Number of cores:
2
Conductor construction:
Class 2, 7×∅1.35 Mm​,min. 7 Wires
Conductor diameter (approx.):
4.0mm
Insulation (×2):
XLPE, Colours: Red/black/blue Etc.
Insulation thickness​:
0.7 Mm​ (10/16 Mm² Class)
Diameter over insulated core:
5.4 Mm(4.0 + 2×0.7)
Filler:
Flame-retardant PP/PE​ To Form Round Assembly
Binder​:
Flame-retardant Tape​ Over Laid-up Cores
Outer sheath:
Flame-retardant PVC (ZR Grade)
Sheath thickness:
1.8 Mm​ (multi-core Rule, ≥1.8 Mm)
Overall cable diameter:
15.0 – 15.5 Mm
Approx. weight:
280 – 320 Kg/km
Long-term service temp.:
90 °C
Short-circuit temp. (≤5 s):
250 °C
Emergency overload:
105–130 °C
Routine test:
3.5 KV AC / 5 Min; Type Test 4.0 KV
Volume resistivity @90 °C:
≥ 10¹² Ω·cm

Product Description

ZR-YJV 2*10mm² Flame Retardant 2 Core Power Cable,0.6/1kV Oxygen-Free Copper,XLPE Insulation PVC Sheath for Building Power Distribution

 

Code Mean:ZR-Flame Retardant,YJ-XLPE Insulation,V-PVC Outer Sheathed.

ZR-YJV 2×10 mm² — Technical Description

1. Product Class. The ZR-YJV 2×10 is a two-core flame-retardant power cable — two identical 10 mm² copper cores, XLPE-insulated, PVC-sheathed, rated 0.6/1 kV (Um = 1.2 kV), 50 Hz. Standards: GB/T 12706.1 / IEC 60502-1, conductor GB/T 3956 / IEC 60228, fire rating GB/T 19666 / GB/T 18380 (default ZC).

 

Building Power Distribution 2 Core Power Cable Braided Flex Oxygen Free Copper

 

2. Construction, Core to Jacket. Two parallel sub-assemblies under one jacket:

Layer Build Wall Diameter
Conductor (×2) Annealed copper, Class 2, 7 × 1.35 mm (7/1.35) each, 10 mm² per core — ≈ 4.05 mm per core
Insulation (×2) Cross-linked polyethylene 0.7 mm ≈ 5.45 mm per core (over ins.)
Lay-up Two cores + non-hygroscopic filler, optional binder tape — ≈ 10.9 mm
Sheath Flame-retarded PVC, ST2, black 1.8 mm ≈ 15.2 mm overall

Weight ≈ 328 kg/km (324–328; Al version ≈ 190–196).

 

3. Electrical Data. DC resistance ≤ 1.83 Ω/km per core @ 20 °C; routine 3.5 kV / 5 min; XLPE volume resistivity ≥ 1×10¹² Ω·cm; insulation resistance typically ≥ 36.7 MΩ·km; capacitance ≤ 0.45 μF/km per core. Reference ampacity (both cores loaded) ≈ 70 A in air and ≈ 90 A direct-buried @ 25 °C — per-cable values; derate per GB/T 16895 / IEC 60364.

 

Parameter

Value

Note

Rated voltage U₀/U

0.6 / 1 kV

Uₘ = 1.2 kV

Test voltage AC (5 min)

3.5 kV​

Routine

Type-test voltage

4.0 kV

IEC 60502

DC resistance @20 °C (Class 2 Cu, per core)​

≤ 1.83 Ω/km​

GB/T 3956 max

AC resistance @90 °C (est.)

≈ 2.38 Ω/km

per core

Current rating in air (30 °C, single circuit, 2-core)

≈ 65 – 72 A​

design ≈ 68 A​

Direct buried (20 °C, soil 1.0 K·m/W, 0.7 m)

≈ 85 – 95 A​

design ≈ 88 A​

Short-circuit current (1 s, Cu, 250 °C, per core)

≈ 1.00 kA

reference

Frequency

50/60 Hz AC (DC usable)

—

 

4. Thermal Limits. Continuous 90 °C; short-circuit 250 °C (≤ 5 s); ambient −20 to +45 °C; laying ≥ 0 °C; minimum bend radius ≥ 15 × OD (multi-core, smaller than the 20 × OD of single cores).

 

ZR-YJV 2×10 mm² Flame-Retardant Copper-Conductor XLPE-Insulated PVC-Sheathed Power Cable — Product Parameters (0.6/1 kV, Two-Core)
Construction: CU / XLPE / PVC, 2 cores  •  Standards: GB/T 12706.1, IEC 60502-1 (cable), GB/T 3956 (conductor), GB/T 19666 & GB/T 18380 (flame retardance)  •  Nominal values for reference — confirm against factory test certificate
No. Category Parameter Value Unit Notes / Standard Reference
A. Product Identification
1 Identification Product name Flame-retardant copper-conductor XLPE-insulated PVC-sheathed power cable (two-core) — Designation ZR-YJV; "ZR" = flame-retardant (halogen-containing)
2 Identification Model designation ZR-YJV 2×10 — 2 cores × 10 mm²; Cu / XLPE / PVC
3 Identification Design standards GB/T 12706.1; IEC 60502-1 — Conductor: GB/T 3956 / IEC 60228; flame retardance: GB/T 19666, GB/T 18380; safety: CCC / production licence
4 Identification Rated voltage U0/U 0.6/1 kV Max system voltage Um = 1.2 kV
5 Identification Rated frequency 50 Hz AC power distribution
6 Identification Number of cores 2 — Two-core cable, both cores live (phase + neutral / L + N applications)
7 Identification Nominal cross-sectional area 10 mm² Per core; nominal cross-section per GB/T 3956
B. Cable Construction (from conductor to outer sheath)
8 Conductor Material Plain annealed copper (Cu) — High-conductivity electrolytic / oxygen-free copper
9 Conductor Conductor class Class 1 or Class 2 (typical: Class 2, stranded) — GB/T 3956 / IEC 60228
10 Conductor Typical stranding construction (per core) 7 wires × 1.35 mm (7/1.35) — Class 2 round stranded; nominal section 10 mm² per core
11 Conductor Conductor diameter (per core) ≈ 4.05 mm Ø of the 7/1.35 stranded core (GB/T 3956 nominal)
12 Conductor Max. DC resistance of conductor at 20 °C 1.83 Ω/km GB/T 3956, Class 2 copper; acceptance criterion for 10 mm²
13 Insulation Material Cross-linked polyethylene (XLPE) — Thermally cross-linked; natural/transparent colour
14 Insulation Nominal insulation thickness 0.7 mm GB/T 12706.1 / IEC 60502-1 (0.6/1 kV, 10 mm²)
15 Insulation Diameter over insulation (per core) ≈ 5.45 mm ≈ 4.05 + 2 × 0.7 (calculated)
16 Lay-up Core assembly Two insulated cores laid up with non-hygroscopic filler; optional binder tape — Round construction, right-hand lay
17 Sheath Material Flame-retardant polyvinyl chloride (PVC, ST2 type) — Colour: black (or as ordered)
18 Sheath Nominal sheath thickness 1.8 mm GB/T 12706.1 / IEC 60502-1 (ahtk & Mingda tables agree)
19 Dimensions Approx. overall diameter 15.2 mm ≈ 15.2 mm (ahtk 15.2; Mingda 15.3)
20 Dimensions Approx. cable weight ≈ 328 kg/km ahtk 328; Mingda 324.2 (aluminium version ≈ 190–196 kg/km)
C. Electrical Performance
21 Electrical Max. DC conductor resistance at 20 °C 1.83 Ω/km GB/T 3956; routine measurement
22 Electrical Power-frequency withstand voltage (routine test) 3.5 kV / 5 min, no breakdown — AC 50 Hz; per GB/T 12706.1 / IEC 60502-1
23 Electrical Insulation resistance (finished cable, 20 °C) ≥ 36.7 MΩ·km Typical finished-cable reference for 0.6/1 kV XLPE cables; varies with geometry and manufacturer test method
24 Electrical XLPE volume resistivity at 20 °C ≥ 1 × 10¹² Ω·cm Material-level requirement (manufacturer reference)
25 Electrical Capacitance (approx., per core) ≤ 0.45 μF/km Manufacturer reference value
26 Electrical Reference ampacity — in air, 25 °C, both cores loaded ≈ 70 A Mingda two-core table (70 A Cu); applies to the cable as a whole; derate per GB/T 16895 / IEC 60364
27 Electrical Reference ampacity — direct burial, 25 °C ≈ 90 A Mingda two-core table (90 A Cu); depends on soil thermal resistivity and depth
D. Thermal Performance
28 Thermal Max. continuous conductor temperature 90 °C XLPE insulation temperature class
29 Thermal Max. conductor temperature under short-circuit (≤ 5 s) 250 °C Per GB/T 12706.1 / IEC 60502-1
30 Thermal Ambient service temperature range -20 to +45 °C Per Qifan datasheet family; check project specification
31 Thermal Min. installation (laying) temperature 0 °C Pre-heat the cable if ambient is below 0 °C
E. Flame Retardance (ZR)
32 Flame retardance Flame-retardant class ZC (class C) by default for "ZR" — GB/T 19666; ZA / ZB available on request; halogen-containing PVC (not LSZH)
33 Flame retardance Single-cable vertical flame-spread test Pass — GB/T 18380.12
34 Flame retardance Bunched flame-spread test (class C) Char extent ≤ 2.5 m above burner bottom edge — GB/T 18380.35: non-metallic volume ≥ 1.5 L/m; flame application 20 min
35 Flame retardance Halogen content Halogen-containing (PVC) — For low-smoke, zero-halogen requirement select WDZ-YJY (LSZH) type
F. Installation
36 Installation Min. bending radius — multi-core cable ≥ 15 × OD — GB 50168 practice for multi-core XLPE cables (Mingda lists 15 × OD); OD = actual cable diameter
37 Installation Laying methods Conduit, tray, cable trench, duct, building trunking, supported/suspended aerial — Also direct burial with mechanical protection where permitted
38 Installation Site withstand test after installation DC 4U0 = 2.4 kV, 15 min (recommended) — Per utility procurement standard Q/GDW 13244.1-2018; practice may vary by project
G. Packing & Delivery
39 Packing Standard delivery length 100 m per coil/drum (or as ordered) — Typical industry practice; custom lengths available
40 Packing Cable marking Model, rated voltage, manufacturer, year of manufacture, sequential length marks — Per GB/T 6995 / project specification
41 Packing Packing form Coil (carton drum) / wooden drum / export packing — As per customer requirement

 

5.Test Parameters

 

ZR-YJV 2×10 mm² — Test / Verification Parameters (per GB/T 12706.1 & IEC 60502-1)
Test Stage Test Item Method / Standard Requirement / Acceptance Criterion Notes
Routine test Conductor DC resistance measurement GB/T 3956 (IEC 60228) ≤ 1.83 Ω/km at 20 °C (per core) Measured on every production length
Routine test Power-frequency withstand voltage GB/T 12706.1 / IEC 60502-1 3.5 kV AC, 5 min, no breakdown Applied between each conductor and earth/water; 50 Hz
Routine test Construction check — insulation & sheath thickness, outer diameter GB/T 2951 Within GB/T 12706.1 tolerances Insulation ≥ 0.7 mm nominal; sheath ≥ 1.8 mm nominal
Sample test Hot set (thermal elongation) test — XLPE insulation GB/T 12706.1 §16.3.13 / GB/T 2951.11 200 ± 3 °C, 15 min, stress 0.2 MPa: elongation under load ≤ 175 %; permanent elongation after cooling ≤ 15 % Verifies degree of cross-linking
Sample test Conductor construction & diameter check GB/T 3956 Class 2; 7 × 1.35 mm; Ø ≈ 4.05 mm Sampled per batch
Type test Single-cable vertical flame-spread test (flame retardance) GB/T 18380.12 No flame spread; charring does not reach top reference point ZR / ZC flame-retardant property
Type test Bunched flame-spread test, class C GB/T 18380.35 Char extent ≤ 2.5 m above burner bottom edge; flame application 20 min; non-metallic volume ≥ 1.5 L/m Class ZC per GB/T 19666
Type test Bending test (mechanical) GB/T 12706.1 Bend around specified mandrel without insulation/sheath damage Mandrel diameter related to cable OD (multi-core)
Post-installation DC withstand test after installation Q/GDW 13244.1-2018 (recommended practice) 4U0 = 2.4 kV DC, 15 min, no breakdown For new installations; verify project specification
Optional Insulation resistance measurement at 20 °C Manufacturer test method ≥ 36.7 MΩ·km (typical finished-cable value) Not a routine item in GB/T 12706.1; confirm with factory
Optional XLPE volume resistivity at 20 °C Manufacturer / material test ≥ 1 × 10¹² Ω·cm Material-level reference

 

6. Fire Performance. Passes GB/T 18380.12 single burn and class-C bunched burn GB/T 18380.35 (char ≤ 2.5 m) → ZC per GB/T 19666. PVC = halogen-bearing; choose WDZ-YJY for LSZH specs.

 

Flame Retardant Data Sheet — ZR-YJV 0.6/1 kV 2x10 mm²
       
1. General Information
Item Value Remarks  
Cable type ZR-YJV 0.6/1 kV 2x10 mm² Copper conductor, XLPE insulated, flame-retardant PVC sheathed
Rated voltage U₀/U 0.6 / 1 kV Uₘ = 1.2 kV  
Number of cores 2 Single-phase (L+N) or DC (+,-)  
Conductor (per core) Cu, Class 2, 7x⌀1.35 mm OD ≈ 4.0 mm  
Insulation XLPE, 0.7 mm nom. 90 °C service  
Outer sheath Flame-retardant PVC, 1.8 mm nom. Multi-core rule (≥1.8 mm)  
Overall OD / Weight ≈ 15.2 mm / ≈ 300 kg/km Design values  
Flame retardant class Class C (per GB/T 19666) ZR default = Class C; modern equiv. ZC  
       
2. Flame Retardant Classification (GB/T 19666 / IEC 60332-3)
Level Designation example Non-metallic volume (L/m) Char height limit
Class A (highest) ZA- / WDZA- ≥ 7.0 ≤ 2.0 m
Class B ZB- / WDZB- 3.5 ≤ 2.5 m
Class C (this product) ZC- / ZR- 1.5 ≤ 2.5 m
Class D (lowest) ZD- 0.5 ≤ 2.5 m
       
3. Flame Retardant Test Items & Technical Requirements (Class C)
No. Test item / Standard Class C limit Result / Note
1 Bunched flame propagation — GB/T 18380.3 / IEC 60332-3-24, Category C Char height ≤ 2.5 m above burner; 20 min; self-extinguishing Pass (required)
2 Single flame — GB/T 18380.1 / IEC 60332-1-2 Self-extinguishing, no re-ignition Pass (required)
3 Specimen non-metallic volume (bundled test) 1.5 L/m (Class C) Pass (required)
4 Flame duration / after-flame time After-flame ≤ 1 h (60 min) for C category per GB/T 18380 Pass (required)
5 pH value of gas (GB/T 17650.2 / IEC 60754-2) * Not a mandatory ZR(C) certified limit; PVC ≠ halogen-free Reference only (see Notes)
6 Conductivity of aq. extract (GB/T 17650.2) * ≤ 10 µS/mm (WDZ certified); not mandated for plain ZR Reference only (see Notes)
7 Halogen acid gas emission (GB/T 17650.1 / IEC 60754-1) * HCl content ≤ 0.5 % (WDZ); PVC contains Cl Reference only (see Notes)
8 Smoke density — transmittance (GB/T 17651 / IEC 61034) * ≥ 60 % (WDZ certified); PVC = heavy dark smoke Reference only (see Notes)
9 Oxygen index LOI (GB/T 2406 / IEC 4589) LOI ≥ 32 % typical for flame-retardant PVC ≥ 32 %
10 Flame retardant filler / binder (ZR grade) FR PP/PE filler + FR tape present Pass (required)
       
4. Important Notes
1. ZR is a legacy designation; under current GB/T 19666-2019 it defaults to Class C. Modern equivalent: ZC. Thus ZR-YJV ≈ ZC-YJV.
2. Items marked * (pH, conductivity, halogen acid gas, smoke density) are REFERENCE / NON-CERTIFIED for plain ZR (Class C) because the PVC sheath contains chlorine. They are NOT mandatory acceptance limits for this product.
3. For genuine halogen-free + low-smoke, use WDZ-YJY 2x10 (polyolefin sheath). For fire-survival (circuit integrity during fire), use NH-ZR-YJV 2x10 (with mica tape, 830 °C / 90 min).
4. Selection logic: Flame retardant only → ZR-YJV (this product, lowest cost); Flame retardant + halogen-free low-smoke → WDZ-YJY; Flame retardant + fire-resistant → NH-ZR-YJV.

 

Flame Retardant Grade Comparison — ZR(C) vs WDZ vs WDZA(A) vs NH vs Plain YJV
             
Property ZR-YJV (this, C) WDZ-YJY WDZA-YJY (A) NH-ZR-YJV Plain YJV Remarks
Flame retardant level Class C Class C Class A Class C None A > B > C > D
Non-metallic volume (L/m) 1.5 1.5 ≥ 7.0 1.5 — Bundled test
Halogen-free (W) No (PVC, Cl) Yes (PO) Yes (PO) No (PVC, Cl) * No * NH uses mica + PVC
Low smoke (D) No Yes (≥ 60 %) Yes (≥ 60 %) No No Smoke transmittance
Flame retardant (Z) Yes (C) Yes (C) Yes (A) Yes (C) No Z =Fire Resistant
Fire-survival / circuit integrity No No No Yes (830 °C, 90 min) No NH =Flame Retardant (IEC 60331)
Sheath material FR-PVC Polyolefin Polyolefin FR-PVC + mica PVC —
pH / corrosivity Corrosive HCl ≥ 4.3 / non-corrosive ≥ 4.3 Corrosive HCl Corrosive WDZ certified only
Cost tier Lowest Medium High Highest Low —
Typical use General, cost-sensitive Metro/hospital/data centre Critical tunnels Emergency feeders No FR req. —
             
Note: This product (ZR-YJV, Class C) provides flame retardancy only (limits flame spread). It does NOT provide certified halogen-free / low-smoke (that requires WDZ- / polyolefin sheath) nor fire-survival circuit integrity (that requires NH- / mica tape).

 

7.Cross Section Structure

 

Building Power Distribution 2 Core Power Cable Braided Flex Oxygen Free Copper

 

ZR-YJV 2×10 mm² — Cable Cross-Section Structure (Schematic)
Two-core construction from conductor to outer sheath · nominal values per GB/T 12706.1 / IEC 60502-1 · not to exact scale
           
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductor (Cu) × 2 Annealed copper, Class 2 stranded — 7 × 1.35 mm per core (7/1.35), nominal 10 mm² per core — ≈ 4.05 (Ø per core) Current-carrying element; max DC resistance ≤ 1.83 Ω/km @ 20 °C (per core)
2 Insulation (XLPE) × 2 Cross-linked polyethylene 0.7 ≈ 5.45 (Ø per core, over insulation) Dielectric barrier; rated 90 °C continuous; withstands 3.5 kV / 5 min
3 Core lay-up Two insulated cores laid up with non-hygroscopic filler; optional binder tape — ≈ 10.9 (Ø over lay-up) Forms a round assembly for sheathing
4 Outer sheath (PVC) Flame-retardant PVC, ST2 type, black 1.8 ≈ 15.2 (Ø overall) Mechanical & moisture protection; flame retardance ZC (ZR) per GB/T 19666
Key Dimensions & Properties
Overall diameter 15.2 mm 15.2–15.3 mm across sources (ahtk 15.2; Mingda 15.3)    
Approx. cable weight ≈ 328 kg/km ahtk 328; Mingda 324.2; Al version ≈ 190–196 kg/km    
Rated voltage 0.6/1 kV AC 50 Hz; max system voltage Um = 1.2 kV    
Max conductor temperature 90 / 250 °C Continuous / short-circuit (≤ 5 s)    
Min. bending radius (multi-core) ≥ 15 × OD — OD = actual cable diameter    
Flame-retardant class ZC (ZR) — GB/T 19666    

 

Product Structure Introduction — ZR-YJV 2×10 mm² (English)
Two-core layered construction description, from conductor to outer sheath · per GB/T 12706.1 & IEC 60502-1 · CU / XLPE / PVC · 0.6/1 kV
 
1. Scope of This Sheet
This sheet describes the physical build of ZR-YJV 2×10, a flame-retardant, two-core low-voltage cable rated 0.6/1 kV AC. It follows GB/T 12706.1 / IEC 60502-1 for manufacture and testing, GB/T 3956 / IEC 60228 for the core, and GB/T 19666 for the ZR (default ZC) class. The finished product is roughly 15.2 mm in diameter, weighs about 328 kg/km and is supplied on 100 m coils or drums.
Both cores are identical live conductors; the cable is intended for fixed wiring rather than trailing service.
 
2. Conductor Sub-Assembly (Per Core)
Each of the two cores is built from seven annealed copper wires of 1.35 mm (7/1.35) stranded to Class 2, giving 10 mm² per core and a core diameter of ≈ 4.05 mm. The 20 °C DC resistance is limited to 1.83 Ω/km per core. Strancing keeps the core flexible enough for conduit pulling despite the compact size.
 
3. Insulation Sub-Assembly (Per Core)
A 0.7 mm layer of XLPE is extruded over each core, bringing the diameter over insulation to ≈ 5.45 mm. The cross-linked material allows continuous service at 90 °C and a five-second fault temperature of 250 °C, with volume resistivity ≥ 1×10¹² Ω·cm. Every production length must hold 3.5 kV AC for five minutes without breakdown.
 
4. Core Assembly & Outer Sheath
The two insulated cores are laid up together with a non-hygroscopic filler (and an optional binder tape) to form a round assembly of ≈ 10.9 mm. A 1.8 mm flame-retardant PVC (ST2) jacket is then extruded over the bundle, closing the cable at ≈ 15.2 mm. The jacket provides the ZC fire rating, verified by GB/T 18380.12 (single burn) and GB/T 18380.35 (class C, char ≤ 2.5 m); PVC is halogen-bearing, so WDZ-YJY remains the zero-halogen option.
 
5. Practical Handling Notes
• Multi-core bend limit: ≥ 15 × OD.  • Run the DC 4U0 = 2.4 kV / 15 min site test before commissioning.  • Service ambient −20 to +45 °C; warm coils below 0 °C.  • Two-core ampacity is per cable — derate for grouping and tray fill.  • Confirm core Ø from the certificate before crimping lugs.

 

8. Verification Regime. Routine: DC resistance, 3.5 kV/5 min, dimensional audit (ins. ≥ 0.7 mm, sheath ≥ 1.8 mm). Sample: XLPE hot-set (200 ± 3 °C / 15 min / 0.2 MPa). Type: flame + bending. Site: DC 4U0 = 2.4 kV / 15 min (Q/GDW 13244.1-2018 practice).

 

9. Handling Precautions. Bend ≥ 15 × OD; unreel without kinking; protect from UV and sharp edges; run the site DC test before energising; both cores are live — do not parallel-load one side only; size lugs to the ≈ 4.05 mm core.

 

Building Power Distribution 2 Core Power Cable Braided Flex Oxygen Free Copper

 

10. Typical Applications. Single-phase lighting and power feeders, L+N circuits, control and instrumentation supplies, small pump and fan circuits, switchboard droppers at 0.6/1 kV — conduits, trays, trunking, trenches; indoor or sheltered outdoor.

 

Building Power Distribution 2 Core Power Cable Braided Flex Oxygen Free Copper

 

11. Ordering Data. ZR-YJV 0.6/1 kV 2×10, length, drum/coil type, marking. Standard 100 m coils/drums; confirm all figures against the factory certificate.

 

Building Power Distribution 2 Core Power Cable Braided Flex Oxygen Free Copper

 

Building Power Distribution 2 Core Power Cable Braided Flex Oxygen Free Copper