2 Core 0.75mm2 Flexible PVC Cable RVV 2x0.75mm2 For Equipment Internal Wiring
Product Summary
Product Details
0.75mm2 flexible pvc cable
,flexible pvc cable rvv
,0.75mm2 flexible power cable
Product Description
2 Core 0.75mm² Flexible PVC Cable RVV-2*0.75mm² for Equipment Internal Wiring
Cable Designation & Meaning
|
Code |
Meaning |
|---|---|
|
RVV |
R = Flexible copper conductor (Class 5), V = PVC insulation, V = PVC sheath |
|
300/500 V |
Rated voltage U₀/U = 300/500 V; Uₘ = 500 V |
|
2×0.75 mm² |
Two flexible cores, each 0.75 mm² copper conductor |
Construction: Light PVC sheathed flexible cord, flat/oval or round profile (2-core)
Note: RVV is a light PVC sheathed flexible cord per GB/T 5023 / IEC 60227. It is NOT a power cable (unlike YJV series). Conductor is Class 5 fine-stranded flexible copper. Common profiles: flat (oval) for 2-core, round for 3+ core. This 2×0.75 variant is widely used for low-power portable appliances, control circuits, and internal wiring.

RVV 2×0.75 mm² — Cable Specification & Engineering Data
1. Product Overview & Rating Summary. RVV 2×0.75 is a compact two-core flexible PVC-insulated PVC-sheathed cord designed for light-duty power and signal interconnection: two 0.75 mm² annealed copper Class 5 flexible conductors, each insulated in PVC and collectively enclosed in one PVC overjacket for 300/500 V, 50 Hz service. It is manufactured and type-tested to GB/T 5023.5 (60227 IEC 52) / IEC 60227-5, with flexible stranded conductors conforming to GB/T 3956. The finished outer diameter is about 6.1 mm and the nominal mass is roughly 55 kg per kilometre (≈ 5.5 kg per 100 m), supplied on 100 m reels or cartons.
2. Layer-by-Layer Construction (Conductor to Jacket).
| Layer | Construction | Wall | Diameter |
|---|---|---|---|
| Conductor (Cu) × 2 | Annealed Cu, Class 5 flexible stranded, 26 × 0.19 mm (1+6+19) each | — | ≈ 1.5 mm |
| Insulation (PVC) × 2 | PVC compound, PVC/C (TI1) | 0.50 mm | ≈ 2.5 mm |
| Core assembly | Two insulated cores laid parallel; interstices filled by sheath extrusion | — | ≈ 5.0 mm (derived) |
| Outer sheath (PVC) | PVC compound, PVC/ST5, black or custom | 0.55 mm | ≈ 6.1 mm (finished) |
3. Electrical Characteristics. Each 0.75 mm² conductor is held to a maximum DC resistance of 26 Ω/km at 20 °C, rising to around 33 Ω/km at the 70 °C operating point. Every length survives the routine 2.0 kV AC power-frequency proof held for five minutes. Finished-cable insulation resistance remains above 0.010 MΩ·km at 70 °C, and typical figures include capacitance ≈ 100 nF/km and 50 Hz AC impedance ≈ 26 Ω/km (resistance-dominant). With both cores energised, reference loading is about 6 A in free air at 25 °C (engineering estimate), and the loop voltage drop at 6 A is about 0.16 V per metre.
Insulation & Sheath Data
|
Property |
Value |
|---|---|
|
Insulation material |
PVC (Type TI2) |
|
Outer sheath material |
PVC (Type ST5) |
|
Long-term service temp. |
70 °C (continuous) |
|
Max. conductor temp. (normal) |
70 °C |
|
Short-circuit temp. (≤5 s) |
160 °C |
|
Emergency overload temp. |
100 °C (≤1 h) |
|
Test voltage AC (5 min) |
2.0 kV |
|
Dielectric strength |
≥ 20 kV/mm |
|
Volume resistivity @20 °C |
≥ 1×10¹³ Ω·cm |
|
Shield |
None as standard (RVVP available) |
Electrical Parameters
|
Parameter |
Value |
Note |
|---|---|---|
|
Rated voltage U₀/U |
300 / 500 V |
Uₘ = 500 V |
|
Test voltage AC (5 min) |
2.0 kV |
Routine |
|
Type-test voltage |
2.5 kV |
IEC 60227 |
|
DC resistance @20 °C (per core) |
≤ 26.0 Ω/km |
GB/T 3956 Class 5 max, 0.75 mm² |
|
AC resistance @70 °C (est.) |
≈ 33.2 Ω/km |
per core |
|
Current rating in air (single-phase, 30 °C) |
≈ 6 – 10 A |
depends on installation method |
|
Current rating (design) |
≈ 7 A |
conservative, per GB/T 16895 |
|
Direct buried |
Not applicable |
light cord, not for direct burial |
|
Short-circuit current (1 s, Cu, 160 °C) |
≈ 0.075 kA (75 A) |
0.75 mm² reference |
|
Frequency |
50/60 Hz AC or DC |
— |
4. Thermal Response & Flame Behaviour. PVC insulation sustains a 70 °C continuous conductor temperature. The cord is rated for service ambients between −15 and +70 °C, must not be uncoiled below 0 °C without pre-conditioning, and uses 25 °C as the reference ambient for ampacity. Flame behaviour meets the single-cable vertical test GB/T 18380.12 (IEC 60332-1), meaning the cord self-extinguishes when the flame source is removed. Because both insulation and sheath are halogenated PVC, the cord emits smoke and hydrogen chloride in a fire; low-smoke zero-halogen projects must specify an LSZH variant.
Temperature Characteristics
|
Property |
Value |
|---|---|
|
Max. conductor operating temp. |
70 °C (continuous) |
|
Max. short-circuit temp. (≤5 s) |
160 °C |
|
Emergency overload temp. |
100 °C (≤1 h) |
|
Min. installation ambient temp. |
−15 °C |
|
Service ambient range |
−15 °C to +70 °C |
|
Flexing temp. range |
−5 °C to +70 °C |
Fire Performance (RVV — Standard, Non-Flame-Retardant)
|
Property |
Value / Requirement |
|---|---|
|
Flame retardant |
GB/T 18380.12 / IEC 60332-1-2 (single cable, self-extinguishing) |
|
Flame retardant class |
None as standard (use ZC-RVV for Class C) |
|
Halogen content |
Contains halogen (PVC) |
|
Smoke density |
Not low-smoke |
|
Corrosivity |
Corrosive (PVC) |
|
Toxicity |
Toxic fumes when burned |
|
EMI shielding |
None (use RVVP for shielded version) |
5. Installation Practice & Handling. Bends must not fall below 6 times the actual outer diameter — about 37 mm for this size. Termination requires stripping 8–10 mm and always using a ferrule on the flexible Class 5 strands to prevent wire fraying. Reels held below 0 °C in storage must be warmed indoors before uncoiling; pulling tension should stay within 30 N, and the cord must never be used as a pulling rope. The 6 A reference requires derating whenever ambient temperature or bundling deviates from reference conditions. This cord is not for direct burial, outdoor UV exposure or continuous repetitive flexing — for those duties choose an armoured cable, a UV-stabilised jacket or a continuous-flex (trunking) cable respectively.
Mechanical & Installation Parameters
|
Parameter |
Value |
Remarks |
|---|---|---|
|
Minimum bending radius |
≥ 6 × OD → ≈ 43 mm at Ø7.2 mm |
flexible cable |
|
Max. pulling tension |
11.25 N per core (0.75 mm² × 15 N/mm²) |
Cu conductor limit |
|
Direct burial |
Not recommended (use buried conduit) |
— |
|
Surface mounting |
Cable tray, conduit, trunking, cable clips |
— |
|
Conduit ID |
≥ 16 mm |
— |
|
Fixing |
cable ties, clips |
— |
|
Impact resistance |
Low (light-duty) |
— |
|
Water resistance |
Limited (PVC sheath) |
— |
|
UV resistance |
Poor (PVC degrades outdoors, use UV-resistant or conduit) |
— |
|
Flex life |
Excellent (Class 5 fine-stranded) |
flexible / portable |
|
Termination note |
Screw terminals, compression lugs, or direct crimp (ferrule recommended) |
— |
6. Typical Service Applications. This cord serves light-duty power and signal connections: mains leads for household appliances, lamp and luminaire internal wiring, instrument and electronic equipment interconnection, low-current control circuits in cabinets, audio and signal leads, office equipment power cords, and small appliance internal wiring. Approved installation methods include fixed wiring inside appliances, cable trunking and indoor ducting in dry locations, both indoors and in covered sheltered spaces.

7. Testing & Quality Assurance Regime. Routine tests on every length include conductor DC resistance verification (≤ 26 Ω/km at 20 °C), the 2.0 kV AC / 5 min withstand, conductor continuity across both cores, and dimensional inspection covering insulation ≥ 0.50 mm, sheath ≥ 0.55 mm and overall diameter ≈ 6.1 mm. Sample and type tests comprise PVC insulation and sheath tensile strength (≥ 10 MPa) with elongation (≥ 100 % insulation / ≥ 125 % sheath), PVC heat deformation at 80 °C, PVC shrinkage at 150 °C, the single-cable vertical flame test, bending and cold-bend tests at −15 °C, and the voltage test after flexing. A factory test certificate accompanies each reel.
Cable Parameters
| RVV 2×0.75 mm² — Full Parameter Sheet | ||||
| Copper-core PVC-insulated PVC-sheathed flexible cord · 300/500 V · GB/T 5023.5 / IEC 60227-5 (60227 IEC 52) · finished Ø ≈ 6.1 mm · ≈ 55 kg/km — cross-referenced industry sample data | ||||
| Section | Parameter | Value | Unit | Remarks / Standard |
| 01 · Identification | ||||
| Cable type | RVV | — | Copper conductor, PVC insulation, PVC sheath, flexible round cord (60227 IEC 52) | |
| Rated voltage (U0/U) | 300/500 | V | AC 50 Hz; maximum system voltage Um = 500 V | |
| Number of cores | 2 | — | Two-core round flexible cord | |
| Nominal cross-sectional area | 0.75 × 2 | mm² | Per conductor | |
| Conductor material | Annealed copper (Cu) | — | Class 5 flexible stranded per GB/T 3956 / IEC 60228 | |
| Insulation material | PVC, PVC/C (TI1) compound | — | 70 °C rated | |
| Sheath material | PVC, PVC/ST5 compound | — | Black or custom colour | |
| Standard reference | GB/T 5023.5 / IEC 60227-5 | — | 60227 IEC 52 RVV flexible cords | |
| 02 · Conductor | ||||
| Stranding (per core) | 26 × 0.19 mm | — | Class 5 flexible lay-up | |
| Conductor diameter | ≈ 1.5 | mm | Strand-lay diameter (est.) | |
| DC resistance @ 20 °C | ≤ 26 | Ω/km | Maximum per GB/T 3956 Class 5 | |
| DC resistance @ 70 °C | ≈ 33 | Ω/km | Temperature-corrected (est.) | |
| Copper mass (both cores) | ≈ 13.4 | kg/km | 2 × 0.75 × 8.89 g/cm³ | |
| Conductor flexibility | Class 5 (flexible) | — | Suitable for repeated bending / appliance leads | |
| 03 · Insulation | ||||
| Insulation thickness (per core) | 0.5 | mm | GB/T 5023.5 specified for 0.75 mm² | |
| Core Ø over insulation | ≈ 2.5 | mm | 1.5 + 2 × 0.5 | |
| Insulation material | PVC, PVC/C (TI1) | — | Thermoplastic, 70 °C rated | |
| Insulation resistance @ 70 °C | ≥ 0.010 | MΩ·km | Finished cable, minimum | |
| PVC insulation tensile strength | ≥ 10 | MPa | Type test | |
| PVC insulation elongation at break | ≥ 100 | % | Type test | |
| Insulation colour | Black / red / blue / yellow-green | — | Standard; custom colour combinations available | |
| 04 · Assembly | ||||
| Core arrangement | Two cores laid parallel and cabled | — | Round 2-core lay-up | |
| Filler | None (interstices filled by extrusion) | — | Compact round shape | |
| Binder tape | Not required | — | Sheath extrudes over the pair | |
| Assembled core Ø | ≈ 5.0 | mm | Derived: 6.1 − 2 × 0.55 sheath | |
| Lay-up direction | Right-hand (S) | — | Standard convention | |
| 05 · Sheath | ||||
| Sheath material | PVC, PVC/ST5 compound | — | Black or custom colour | |
| Sheath thickness | 0.55 | mm | Per GB/T 5023.5 for ≈ 5.0 mm assembled Ø | |
| Overall finished diameter | ≈ 6.1 | mm | Cross-referenced industry 2-core sample | |
| Approximate cable mass | ≈ 55 | kg/km | Cross-referenced industry data | |
| PVC sheath tensile strength | ≥ 10 | MPa | Type test | |
| PVC sheath elongation at break | ≥ 125 | % | Type test | |
| Mass per 100 m | ≈ 5.5 | kg/100 m | For reel / carton loading estimation | |
| 06 · Electrical | ||||
| Rated voltage U0/U | 300/500 | V | AC 50 Hz | |
| Maximum system voltage Um | 500 | V | — | |
| DC resistance @ 20 °C | ≤ 26 | Ω/km | GB/T 3956 Class 5 | |
| AC impedance @ 50 Hz | ≈ 26 | Ω/km | R-dominant; negligible reactance | |
| Capacitance (typical) | ≈ 100 | nF/km | Per core (est.) | |
| Insulation resistance @ 70 °C | ≥ 0.010 | MΩ·km | Finished cable, minimum | |
| Routine test voltage | 2.0 kV AC / 5 min | — | Power-frequency withstand, no breakdown | |
| Air ampacity @ 25 °C | ≈ 6 | A | Two cores loaded, Cu (est.) | |
| Voltage drop @ 6 A | ≈ 0.16 | V/m | 2 × 26 × 6 / 1000 (est.) | |
| 07 · Thermal | ||||
| Max continuous conductor temp. | 70 | °C | PVC rated | |
| Max ambient temp. (service) | +70 | °C | Conductor-limited | |
| Min ambient temp. (service) | −15 | °C | PVC flexibility limit | |
| Min laying temperature | 0 | °C | Warm reels below 0 °C | |
| Thermal coefficient of resistance (Cu) | 0.00393 | 1/°C | At 20 °C reference | |
| 08 · Flame (flammability) | ||||
| Flame-retardant behaviour | Non-flame-spreading | — | Per GB/T 18380.12 (IEC 60332-1) | |
| Halogen content | Halogen-bearing (PVC) | — | Emits HCl under fire | |
| Smoke emission | Emits smoke under fire | — | PVC insulation and sheath | |
| Special LSZH version | Not standard | — | Specify LSZH variant for public areas | |
| 09 · Installation | ||||
| Min bending radius (flexible cord) | ≥ 6 × OD ≈ 37 | mm | OD = actual finished diameter | |
| Max pulling tension | ≤ 30 | N | ≈ 20 N/mm² of total copper area (est.) | |
| Laying methods | Fixed wiring inside appliances, ducting, trunking | — | Indoor dry locations | |
| Outdoor / burial note | Not for direct burial or outdoor UV exposure | — | Use UV-stabilised or armoured cable if required | |
| Termination | Solder, crimp ferrule or screw terminal | — | Strip 8–10 mm for flexible Class 5 conductors | |
| Flexing / flexible use | Suitable for occasional movement | — | Not for continuous repetitive flexing (use H05VV5-F if so) | |
| 10 · Packing | ||||
| Standard supply length | 100 | m/reel or carton | Custom lengths available | |
| Reel / packing type | Plastic reel or carton | — | Sealed until installation | |
| Surface marking | Type, voltage, supplier, year, metre marks | — | Per GB/T 6995 | |
| Storage conditions | Dry, covered, −15 to +40 °C | — | Away from sunlight, moisture, oils, sharp objects | |
| Transport | Reels secured against rolling | — | Do not drag cable over rough ground | |
Cable Test Parameters
| Test Parameters — RVV 2×0.75 mm² | ||||
| No. | Test Item | Test Condition / Method | Requirement | Type |
| 1 | Conductor DC resistance | GB/T 3048.4, 20 °C | ≤ 26 Ω/km per conductor | Routine |
| 2 | Power-frequency withstand | 2.0 kV AC, 5 min | No breakdown | Routine |
| 3 | Insulation resistance @ 70 °C | GB/T 3048.5, 70 °C | ≥ 0.010 MΩ·km | Routine |
| 4 | Conductor continuity | Visual + electrical | Both cores continuous | Routine |
| 5 | Dimensional check | Micrometer | Insulation ≥ 0.5 mm; sheath ≥ 0.55 mm; OD ≈ 6.1 mm | Routine |
| 6 | PVC insulation tensile & elongation | GB/T 2951.11 | Tensile ≥ 10 MPa; elongation ≥ 100 % | Type |
| 7 | PVC sheath tensile & elongation | GB/T 2951.11 | Tensile ≥ 10 MPa; elongation ≥ 125 % | Type |
| 8 | PVC heat deformation | 80 °C, 4 h, load | Deformation ≤ 50 % | Type |
| 9 | PVC shrinkage test | 150 °C, 1 h | Shrinkage ≤ 4 % | Type |
| 10 | Single-cable vertical flame | GB/T 18380.12 | Self-extinguishing; char ≤ 50 mm above burner | Type |
| 11 | Bending / flexing test | ≥ 6 × OD mandrel | No crack in insulation or sheath | Type |
| 12 | Cold bend test | −15 °C, 4 h | No cracking after mandrel bend | Type |
| 13 | Ozone / weathering (outdoor variant) | As required | Per customer specification | Optional |
| 14 | Voltage test after bending | 2.0 kV AC, 5 min | No breakdown after flexing | Type |
| 15 | Marking legibility | Visual + rubbing | Type/voltage/supplier/metre marks legible | Routine |
| 16 | Core identification | Visual + continuity | Correct colour-coded conductors identified | Routine |
Cable Cross Section Structure

| RVV 2×0.75 mm² — Cross-Section Construction Diagram (Schematic) | |||||
| Layered 2-core flexible build-up from fine copper strands to PVC jacket · nominal dimensions per GB/T 5023.5 / IEC 60227-5 · finished Ø ≈ 6.1 mm per cross-referenced industry sample | |||||
| No. | Layer | Material / Construction | Nominal Thickness (mm) | Diameter (mm) | Function / Remarks |
| 1 | Conductor (Cu) × 2 | Annealed copper, Class 5 flexible stranded — 26 wires of 0.19 mm per core (1+6+19 layout), nominal area 0.75 mm² each | — | ≈ 1.5 (Ø each conductor) | Flexible line conductors; DC resistance capped at 26 Ω/km at 20 °C |
| 2 | Insulation (PVC) × 2 | PVC compound, PVC/C (TI1) | 0.5 | ≈ 2.5 (Ø each insulated core) | Electrical isolation; 70 °C continuous rating; withstands 2.0 kV for 5 min |
| 3 | Core assembly | Two insulated cores laid parallel and cabled; interstices filled by sheath extrusion | — | ≈ 5.0 (Ø over assembled cores) | Round 2-core lay-up; derived from finished Ø 6.1 − 2×0.55 sheath |
| 4 | Outer sheath (PVC) | PVC compound, PVC/ST5, black or custom | 0.55 | ≈ 6.1 (Ø finished cable) | Mechanical protection and abrasion resistance; non-flame-spreading per GB/T 18380.12 |
| Key Dimensions & Properties (expanded) | |||||
| Finished cable diameter | ≈ 6.1 | mm | Cross-referenced industry 2-core sample | ||
| Approximate cable mass | ≈ 55 | kg/km | Cu build-up (cross-referenced industry data) | ||
| Nominal voltage rating | 300/500 | V | AC 50 Hz; maximum system voltage Um = 500 V | ||
| Conductor temperature limit | 70 | °C | Continuous service | ||
| Minimum bend radius (flexible) | ≥ 6 × OD ≈ 37 | mm | OD = actual finished cable diameter | ||
| Flame behaviour | Non-flame-spreading | — | Per GB/T 18380.12 | ||
| Conductor DC resistance | ≤ 26 | Ω/km | At 20 °C, per GB/T 3956 Class 5 | ||
| Insulation resistance @ 70 °C | ≥ 0.010 | MΩ·km | Finished cable, minimum | ||
| Routine test voltage | 2.0 kV AC / 5 min | — | Power-frequency withstand | ||
| AC impedance @ 50 Hz | ≈ 26 | Ω/km | R-dominant (est.) | ||
| Capacitance (typical) | ≈ 100 | nF/km | Per core (est.) | ||
| Air ampacity @ 25 °C | ≈ 6 | A | Two cores loaded, Cu (est.) | ||
| Voltage drop @ 6 A | ≈ 0.16 | V/m | Loop drop (est.) | ||
| Maximum pulling tension | ≤ 30 | N | ≈ 20 N/mm² of total copper area (est.) | ||
| Mass per 100 m | ≈ 5.5 | kg/100 m | For reel / carton loading | ||
| Schematic — not to exact scale. Finished Ø ≈ 6.1 mm and weight ≈ 55 kg/km from cross-referenced industry samples; conductor/insulation diameters calculated from GB/T 3956 and GB/T 5023.5; ampacity 6 A is an engineering estimate for 2-core flexible cords. Values marked (est.) require confirmation against the factory test certificate. | |||||
Construction Description
| Construction Description — RVV 2×0.75 mm² | |||
| Layer-by-layer build-up narrative, conductor through outer jacket · per GB/T 5023.5 & IEC 60227-5 · CU / PVC / PVC · 300/500 V class · finished Ø ≈ 6.1 mm (cross-referenced industry sample) | |||
| 1. Product Identity & Ratings | |||
| RVV 2×0.75 is a compact two-core flexible PVC cord designed for light-duty power and signal interconnection: two 0.75 mm² annealed copper conductors, each insulated in PVC and collectively sheathed in a second PVC overjacket, rated for 300/500 V AC at 50 Hz and a 70 °C conductor temperature. It is manufactured and type-tested to GB/T 5023.5 (60227 IEC 52) / IEC 60227-5, with Class 5 flexible conductors per GB/T 3956. The finished diameter is about 6.1 mm (cross-referenced industry sample) and the nominal mass is roughly 55 kg per kilometre (≈ 5.5 kg per 100 m), supplied on 100 m reels or cartons. | |||
| With both cores energised, the cord carries about 6 A in free air at 25 °C (engineering estimate), suited to appliance leads, lamp connections, instrument wiring and low-current control circuits rather than heavy distribution feeders. | |||
| 2. Flexible Copper Conductors | |||
| Each 0.75 mm² conductor is stranded from twenty-six 0.19 mm annealed wires in the 1+6+19 arrangement — the Class 5 flexible standard at this cross-section — giving a strand-lay diameter of about 1.5 mm and a DC resistance ceiling of 26 Ω/km at 20 °C (about 33 Ω/km at the 70 °C operating point). The many fine wires give the cord its flexibility and bending endurance, which is why it is preferred for appliance connections and equipment leads rather than fixed building wiring. Copper mass is about 6.7 kg/km per core, 13.4 kg/km in total. | |||
| 3. PVC Insulation | |||
| PVC is extruded at 0.50 mm onto each 0.75 mm² conductor, producing approximately 2.5 mm per insulated core. The insulation is rated for 70 °C continuous duty, passes the routine 2.0 kV AC five-minute voltage proof, and maintains insulation resistance above 0.010 MΩ·km at 70 °C. Insulation colours are standardised (commonly brown/blue for 230 V mains, or red/black for DC and signal circuits) and may be specified to order. | |||
| 4. Cabling & PVC Outer Sheath | |||
| After insulation, the two cores are laid parallel and cabled; the interstices are filled by the extruded sheath itself, forming a compact round bundle of about 5.0 mm diameter. A 0.55 mm layer of PVC (ST5 compound) is then extruded over the pair to the ≈ 6.1 mm finish. The jacket provides abrasion resistance and mechanical protection, and the whole cord meets the single-cable vertical flame test GB/T 18380.12. Because both insulation and sheath are halogenated PVC, the cord emits smoke and HCl in a fire; for public or confined spaces, specify a low-smoke zero-halogen variant. | |||
| 5. Site Handling & Operational Notes | |||
| • Observe the 6 × OD minimum bending radius (≈ 37 mm). • Strip 8–10 mm for termination and always use a ferrule on the flexible Class 5 strands to prevent wire fraying. • Service ambient spans −15 to +70 °C; warm reels indoors before pulling below 0 °C. • The 6 A reference requires derating for ambient temperature and bundling. • Maximum pulling tension ≤ 30 N; do not use the cord as a pulling rope. • Not for direct burial, outdoor UV exposure or continuous repetitive flexing — for those duties choose an armoured cable, UV-stabilised jacket or a continuous-flex (trunking) cable respectively. • Use reels with flanges suited to the ≈ 6.1 mm OD. |
8. Standards & Conformity. Design and production are governed by GB/T 5023.5 and IEC 60227-5 for 300/500 V flexible cords (60227 IEC 52). Conductors satisfy GB/T 3956 / IEC 60228 Class 5 — the 0.75 mm² conductor as twenty-six wires of 0.19 mm with R ≤ 26 Ω/km. Flame behaviour is proven by GB/T 18380.12. General test methods follow GB 5023.1 / GB 5023.3, while surface marking complies with GB/T 6995. Cables can also be supplied to IEC, BS, DIN, UL or VDE requirements on request. Because the PVC jacket contains halogen, tunnels, metro systems, hospitals and other confined public areas call for an LSZH variant.
9. Packaging, Storage & Logistics. Standard delivery is 100 m per reel or carton, with bespoke cut lengths available on request. Each reel carries type, voltage, supplier identity, production year and sequential metre marking per GB/T 6995. Storage should be in dry, covered premises at −15 to +40 °C, shielded from direct sunlight, moisture, oils and sharp objects; reels remain sealed until installation. In cold conditions, condition reels indoors to ≥ 0 °C before uncoiling. During transit, reels must be secured against rolling and impact, and the cord must never be dragged across abrasive ground or sharp edges.

10. Procurement Specification. State "RVV 300/500 V 2×0.75" together with the required length or reel arrangement, insulation colour combination and marking preferences. Specify the sheath colour (black is standard) and any special colour-coding (e.g. brown/blue for 230 V mains, red/black for DC). Always request the factory test certificate to confirm the actual diameter (≈ 6.1 mm), weight (≈ 55 kg/km) and conductor resistance for the production batch. Where low-smoke zero-halogen or continuous-flex construction is needed, order the LSZH or H05VV5-F variant respectively.
11. Cable Industry FAQ.
- Q1: How does RVV differ from RVVP or RVVSP? RVV is the plain unshielded round flexible cord. RVVP adds a tinned-copper braid screen for electromagnetic interference rejection, and RVVSP additionally twists the pairs — choose these variants when the circuit carries low-level signals or is routed near noisy equipment.
- Q2: Why a 0.75 mm² cross-section for mains leads? For a 6 A load at 230 V, 0.75 mm² is the standard minimum for appliance supply cords under IEC 60227 and GB/T 5023. Larger loads require 1.0, 1.5 or 2.5 mm² conductors.
- Q3: What does Class 5 flexible conductor mean? Class 5 (GB/T 3956) is made of many thin wires (26 × 0.19 mm at 0.75 mm²), giving the cord its flexibility and bend endurance. Class 2 (used in power cables like YJV) uses fewer thicker wires and is much stiffer — never mix them up when ordering.
- Q4: Can RVV be used outdoors? Not in its standard form: the PVC jacket is not UV-stabilised and will degrade under prolonged sunlight. For outdoor use specify a UV-stabilised jacket or an armoured cable. For burial, use a steel-tape armoured power cable.
- Q5: How is the conductor cross-section chosen for an appliance lead? Selection follows (a) full-load current after derating, (b) permissible voltage drop (typically ≤ 5 % for appliance leads), and (c) coordination with the upstream fuse or circuit breaker. A 0.75 mm² cord supports up to about 6 A; higher loads require 1.0 mm² or larger.
- Q6: Copper or tinned copper conductor? Bare annealed copper (this RVV) is standard for fixed appliance leads and gives the lowest resistance. Tinned copper is preferred where the conductor may be exposed to moisture or where solder termination is used, because it resists oxidation.
- Q7: Why can PVC only run at 70 °C while XLPE runs at 90 °C? PVC is a thermoplastic that softens and deforms at elevated temperature; XLPE is cross-linked into a thermoset network that retains its shape up to 90 °C. This is why RVV (PVC) is limited to 70 °C and YJV (XLPE) to 90 °C.
- Q8: What is the difference between RVV and RVB/RVS? RVV is a round sheathed cable; RVB is a flat parallel unsheathed twin cord, and RVS is a twisted pair unsheathed. The round RVV is preferred where mechanical protection or a clean outer appearance is needed.
- Q9: Why does finished diameter vary between manufacturers for the same nominal size? Standards set minimum insulation and sheath thicknesses plus electrical performance, but not a precise overall diameter. Stranding compaction, filler design and sheath tolerance differ between plants — published 2×0.75 figures cluster around 6.1 mm — so the actual measured diameter must be used when sizing glands and clips.
- Q10: Which tests confirm acceptability on delivery and before energisation? At delivery, verify the factory test certificate (resistance ≤ 26 Ω/km, 2.0 kV/5 min withstand, dimensions ≈ 6.1 mm), jacket legibility and reel integrity. After installation, complete an insulation-resistance test plus a 2.0 kV AC / 5 min withstand, then confirm both conductors identified correctly before energising.
- Q11: What service life can be expected? When installed and operated within the stated temperature and voltage limits, PVC flexible cords are designed for a service life of around 10–15 years in dry indoor conditions; sustained overload, repeated flexing beyond the 6 × OD minimum radius, ultraviolet exposure, or operation above 70 °C will materially shorten that life.