2 Core 0.75mm2 Flexible PVC Cable RVV 2x0.75mm2 For Equipment Internal Wiring

2 Core 0.75mm2 Flexible PVC Cable RVV 2x0.75mm2 For Equipment Internal Wiring

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
RVV-2*0.75mm²

Trading Properties

moq
1 Meter
payment method
L/C,T/T
supply capacity
100000 meters per month

Product Summary

2 Core 0.75mm² Flexible PVC Cable RVV-2*0.75mm² for Equipment Internal Wiring Cable Designation & Meaning Code Meaning RVV R = Flexible copper conductor (Class 5), V = PVC insulation, V = PVC sheath 300/500 V Rated voltage U₀/U = 300/500 V; Uₘ = 500 V 2×0.75 mm² Two flexible cores, each 0.75 mm² ...

Product Details

Highlight:

0.75mm2 flexible pvc cable

,

flexible pvc cable rvv

,

0.75mm2 flexible power cable

Conductor (×2):
Bare Annealed Copper, Class 5 Fine-stranded Flexible, 24×∅0.20 Mm (typical), Conductor Ø ≈ 1.2–1.4 Mm
Conductor nominal area:
0.75 Mm²
Number of cores:
2
Conductor class:
Class 5 Flexible
Conductor construction:
24×∅0.20 Mm (typical)
Conductor diameter (approx.):
1.2–1.4 Mm
Insulation (×2):
PVC (Type TI2 Or Equivalent), Colours: Brown (L) + Blue (N) For Single-phase AC, Or Brown + Blue (DC Polarity Optional)
Insulation thickness:
0.6 Mm (nominal, Per GB/T 5023 For 0.75 Mm²)
Assembly:
Two Insulated Cores Laid Up Side-by-side (flat/oval) Or Twisted (round)
Diameter over insulated core:
2.4–2.8 Mm
Outer sheath:
PVC (Type TM2 Or Equivalent), Light Grade
Sheath thickness:
0.8 Mm (nominal, GB/T 5023 For 2-core ≤0.75 Mm²)
Sheath color:
White, Black, Or Grey (standard); Custom Colours Available
Overall cable dimensions:
Flat: ≈ 3.6–4.2 × 5.8–6.8 Mm; Round: Ø ≈ 5.8–6.8 Mm
Design outer diameter (round equivalent):
≈ 6.2 Mm
Approx. weight:
45 – 65 G/m (45–65 Kg/km)
Design weight:
≈ 52 Kg/km
Cable shape:
Flat (oval) Or Round

Product Description

2 Core 0.75mm² Flexible PVC Cable RVV-2*0.75mm² for Equipment Internal Wiring


Cable Designation & Meaning

Code

Meaning

RVV

R = Flexible copper conductor (Class 5), V = PVC insulation, V = PVC sheath

300/500 V

Rated voltage U₀/U = 300/500 V; Uₘ = 500 V

2×0.75 mm²

Two flexible cores, each 0.75 mm² copper conductor


Construction: Light PVC sheathed flexible cord, flat/oval or round profile (2-core)

Note: RVV is a light PVC sheathed flexible cord per GB/T 5023 / IEC 60227. It is NOT a power cable (unlike YJV series). Conductor is Class 5 fine-stranded flexible copper. Common profiles: flat (oval) for 2-core, round for 3+ core. This 2×0.75 variant is widely used for low-power portable appliances, control circuits, and internal wiring.


2 Core 0.75mm2 Flexible PVC Cable RVV 2x0.75mm2 For Equipment Internal Wiring


RVV 2×0.75 mm² — Cable Specification & Engineering Data 

1. Product Overview & Rating Summary. RVV 2×0.75 is a compact two-core flexible PVC-insulated PVC-sheathed cord designed for light-duty power and signal interconnection: two 0.75 mm² annealed copper Class 5 flexible conductors, each insulated in PVC and collectively enclosed in one PVC overjacket for 300/500 V, 50 Hz service. It is manufactured and type-tested to GB/T 5023.5 (60227 IEC 52) / IEC 60227-5, with flexible stranded conductors conforming to GB/T 3956. The finished outer diameter is about 6.1 mm and the nominal mass is roughly 55 kg per kilometre (≈ 5.5 kg per 100 m), supplied on 100 m reels or cartons.


2. Layer-by-Layer Construction (Conductor to Jacket).

Layer Construction Wall Diameter
Conductor (Cu) × 2 Annealed Cu, Class 5 flexible stranded, 26 × 0.19 mm (1+6+19) each — ≈ 1.5 mm
Insulation (PVC) × 2 PVC compound, PVC/C (TI1) 0.50 mm ≈ 2.5 mm
Core assembly Two insulated cores laid parallel; interstices filled by sheath extrusion — ≈ 5.0 mm (derived)
Outer sheath (PVC) PVC compound, PVC/ST5, black or custom 0.55 mm ≈ 6.1 mm (finished)


3. Electrical Characteristics. Each 0.75 mm² conductor is held to a maximum DC resistance of 26 Ω/km at 20 °C, rising to around 33 Ω/km at the 70 °C operating point. Every length survives the routine 2.0 kV AC power-frequency proof held for five minutes. Finished-cable insulation resistance remains above 0.010 MΩ·km at 70 °C, and typical figures include capacitance ≈ 100 nF/km and 50 Hz AC impedance ≈ 26 Ω/km (resistance-dominant). With both cores energised, reference loading is about 6 A in free air at 25 °C (engineering estimate), and the loop voltage drop at 6 A is about 0.16 V per metre.

Insulation & Sheath Data

Property

Value

Insulation material

PVC (Type TI2)

Outer sheath material

PVC (Type ST5)

Long-term service temp.

70 °C (continuous)

Max. conductor temp. (normal)

70 °C

Short-circuit temp. (≤5 s)

160 °C

Emergency overload temp.

100 °C (≤1 h)

Test voltage AC (5 min)

2.0 kV

Dielectric strength

≥ 20 kV/mm

Volume resistivity @20 °C

≥ 1×10¹³ Ω·cm

Shield

None as standard (RVVP available)


Electrical Parameters


Parameter

Value

Note

Rated voltage U₀/U

300 / 500 V

Uₘ = 500 V

Test voltage AC (5 min)

2.0 kV

Routine

Type-test voltage

2.5 kV

IEC 60227

DC resistance @20 °C (per core)

≤ 26.0 Ω/km

GB/T 3956 Class 5 max, 0.75 mm²

AC resistance @70 °C (est.)

≈ 33.2 Ω/km

per core

Current rating in air (single-phase, 30 °C)

≈ 6 – 10 A

depends on installation method

Current rating (design)

≈ 7 A

conservative, per GB/T 16895

Direct buried

Not applicable

light cord, not for direct burial

Short-circuit current (1 s, Cu, 160 °C)

≈ 0.075 kA (75 A)

0.75 mm² reference

Frequency

50/60 Hz AC or DC

—


4. Thermal Response & Flame Behaviour. PVC insulation sustains a 70 °C continuous conductor temperature. The cord is rated for service ambients between −15 and +70 °C, must not be uncoiled below 0 °C without pre-conditioning, and uses 25 °C as the reference ambient for ampacity. Flame behaviour meets the single-cable vertical test GB/T 18380.12 (IEC 60332-1), meaning the cord self-extinguishes when the flame source is removed. Because both insulation and sheath are halogenated PVC, the cord emits smoke and hydrogen chloride in a fire; low-smoke zero-halogen projects must specify an LSZH variant.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

70 °C (continuous)

Max. short-circuit temp. (≤5 s)

160 °C

Emergency overload temp.

100 °C (≤1 h)

Min. installation ambient temp.

−15 °C

Service ambient range

−15 °C to +70 °C

Flexing temp. range

−5 °C to +70 °C

Fire Performance (RVV — Standard, Non-Flame-Retardant)

Property

Value / Requirement

Flame retardant

GB/T 18380.12 / IEC 60332-1-2​ (single cable, self-extinguishing)

Flame retardant class

None​ as standard (use ZC-RVV for Class C)

Halogen content

Contains halogen (PVC)

Smoke density

Not low-smoke

Corrosivity

Corrosive (PVC)

Toxicity

Toxic fumes when burned

EMI shielding

None (use RVVP for shielded version)

5. Installation Practice & Handling. Bends must not fall below 6 times the actual outer diameter — about 37 mm for this size. Termination requires stripping 8–10 mm and always using a ferrule on the flexible Class 5 strands to prevent wire fraying. Reels held below 0 °C in storage must be warmed indoors before uncoiling; pulling tension should stay within 30 N, and the cord must never be used as a pulling rope. The 6 A reference requires derating whenever ambient temperature or bundling deviates from reference conditions. This cord is not for direct burial, outdoor UV exposure or continuous repetitive flexing — for those duties choose an armoured cable, a UV-stabilised jacket or a continuous-flex (trunking) cable respectively.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 6 × OD → ≈ 43 mm at Ø7.2 mm

flexible cable

Max. pulling tension

11.25 N per core (0.75 mm² × 15 N/mm²)

Cu conductor limit

Direct burial

Not recommended (use buried conduit)

—

Surface mounting

Cable tray, conduit, trunking, cable clips

—

Conduit ID

≥ 16 mm

—

Fixing

cable ties, clips

—

Impact resistance

Low (light-duty)

—

Water resistance

Limited (PVC sheath)

—

UV resistance

Poor (PVC degrades outdoors, use UV-resistant or conduit)

—

Flex life

Excellent (Class 5 fine-stranded)

flexible / portable

Termination note

Screw terminals, compression lugs, or direct crimp (ferrule recommended)

—


6. Typical Service Applications. This cord serves light-duty power and signal connections: mains leads for household appliances, lamp and luminaire internal wiring, instrument and electronic equipment interconnection, low-current control circuits in cabinets, audio and signal leads, office equipment power cords, and small appliance internal wiring. Approved installation methods include fixed wiring inside appliances, cable trunking and indoor ducting in dry locations, both indoors and in covered sheltered spaces.


2 Core 0.75mm2 Flexible PVC Cable RVV 2x0.75mm2 For Equipment Internal Wiring


7. Testing & Quality Assurance Regime. Routine tests on every length include conductor DC resistance verification (≤ 26 Ω/km at 20 °C), the 2.0 kV AC / 5 min withstand, conductor continuity across both cores, and dimensional inspection covering insulation ≥ 0.50 mm, sheath ≥ 0.55 mm and overall diameter ≈ 6.1 mm. Sample and type tests comprise PVC insulation and sheath tensile strength (≥ 10 MPa) with elongation (≥ 100 % insulation / ≥ 125 % sheath), PVC heat deformation at 80 °C, PVC shrinkage at 150 °C, the single-cable vertical flame test, bending and cold-bend tests at −15 °C, and the voltage test after flexing. A factory test certificate accompanies each reel.


Cable Parameters


RVV 2×0.75 mm² — Full Parameter Sheet
Copper-core PVC-insulated PVC-sheathed flexible cord · 300/500 V · GB/T 5023.5 / IEC 60227-5 (60227 IEC 52) · finished Ø ≈ 6.1 mm · ≈ 55 kg/km — cross-referenced industry sample data
Section Parameter Value Unit Remarks / Standard
01 · Identification

Cable type RVV — Copper conductor, PVC insulation, PVC sheath, flexible round cord (60227 IEC 52)

Rated voltage (U0/U) 300/500 V AC 50 Hz; maximum system voltage Um = 500 V

Number of cores 2 — Two-core round flexible cord

Nominal cross-sectional area 0.75 × 2 mm² Per conductor

Conductor material Annealed copper (Cu) — Class 5 flexible stranded per GB/T 3956 / IEC 60228

Insulation material PVC, PVC/C (TI1) compound — 70 °C rated

Sheath material PVC, PVC/ST5 compound — Black or custom colour

Standard reference GB/T 5023.5 / IEC 60227-5 — 60227 IEC 52 RVV flexible cords
02 · Conductor

Stranding (per core) 26 × 0.19 mm — Class 5 flexible lay-up

Conductor diameter ≈ 1.5 mm Strand-lay diameter (est.)

DC resistance @ 20 °C ≤ 26 Ω/km Maximum per GB/T 3956 Class 5

DC resistance @ 70 °C ≈ 33 Ω/km Temperature-corrected (est.)

Copper mass (both cores) ≈ 13.4 kg/km 2 × 0.75 × 8.89 g/cm³

Conductor flexibility Class 5 (flexible) — Suitable for repeated bending / appliance leads
03 · Insulation

Insulation thickness (per core) 0.5 mm GB/T 5023.5 specified for 0.75 mm²

Core Ø over insulation ≈ 2.5 mm 1.5 + 2 × 0.5

Insulation material PVC, PVC/C (TI1) — Thermoplastic, 70 °C rated

Insulation resistance @ 70 °C ≥ 0.010 MΩ·km Finished cable, minimum

PVC insulation tensile strength ≥ 10 MPa Type test

PVC insulation elongation at break ≥ 100 % Type test

Insulation colour Black / red / blue / yellow-green — Standard; custom colour combinations available
04 · Assembly

Core arrangement Two cores laid parallel and cabled — Round 2-core lay-up

Filler None (interstices filled by extrusion) — Compact round shape

Binder tape Not required — Sheath extrudes over the pair

Assembled core Ø ≈ 5.0 mm Derived: 6.1 − 2 × 0.55 sheath

Lay-up direction Right-hand (S) — Standard convention
05 · Sheath

Sheath material PVC, PVC/ST5 compound — Black or custom colour

Sheath thickness 0.55 mm Per GB/T 5023.5 for ≈ 5.0 mm assembled Ø

Overall finished diameter ≈ 6.1 mm Cross-referenced industry 2-core sample

Approximate cable mass ≈ 55 kg/km Cross-referenced industry data

PVC sheath tensile strength ≥ 10 MPa Type test

PVC sheath elongation at break ≥ 125 % Type test

Mass per 100 m ≈ 5.5 kg/100 m For reel / carton loading estimation
06 · Electrical

Rated voltage U0/U 300/500 V AC 50 Hz

Maximum system voltage Um 500 V —

DC resistance @ 20 °C ≤ 26 Ω/km GB/T 3956 Class 5

AC impedance @ 50 Hz ≈ 26 Ω/km R-dominant; negligible reactance

Capacitance (typical) ≈ 100 nF/km Per core (est.)

Insulation resistance @ 70 °C ≥ 0.010 MΩ·km Finished cable, minimum

Routine test voltage 2.0 kV AC / 5 min — Power-frequency withstand, no breakdown

Air ampacity @ 25 °C ≈ 6 A Two cores loaded, Cu (est.)

Voltage drop @ 6 A ≈ 0.16 V/m 2 × 26 × 6 / 1000 (est.)
07 · Thermal

Max continuous conductor temp. 70 °C PVC rated

Max ambient temp. (service) +70 °C Conductor-limited

Min ambient temp. (service) −15 °C PVC flexibility limit

Min laying temperature 0 °C Warm reels below 0 °C

Thermal coefficient of resistance (Cu) 0.00393 1/°C At 20 °C reference
08 · Flame (flammability)

Flame-retardant behaviour Non-flame-spreading — Per GB/T 18380.12 (IEC 60332-1)

Halogen content Halogen-bearing (PVC) — Emits HCl under fire

Smoke emission Emits smoke under fire — PVC insulation and sheath

Special LSZH version Not standard — Specify LSZH variant for public areas
09 · Installation

Min bending radius (flexible cord) ≥ 6 × OD ≈ 37 mm OD = actual finished diameter

Max pulling tension ≤ 30 N ≈ 20 N/mm² of total copper area (est.)

Laying methods Fixed wiring inside appliances, ducting, trunking — Indoor dry locations

Outdoor / burial note Not for direct burial or outdoor UV exposure — Use UV-stabilised or armoured cable if required

Termination Solder, crimp ferrule or screw terminal — Strip 8–10 mm for flexible Class 5 conductors

Flexing / flexible use Suitable for occasional movement — Not for continuous repetitive flexing (use H05VV5-F if so)
10 · Packing

Standard supply length 100 m/reel or carton Custom lengths available

Reel / packing type Plastic reel or carton — Sealed until installation

Surface marking Type, voltage, supplier, year, metre marks — Per GB/T 6995

Storage conditions Dry, covered, −15 to +40 °C — Away from sunlight, moisture, oils, sharp objects

Transport Reels secured against rolling — Do not drag cable over rough ground


Cable Test Parameters


Test Parameters — RVV 2×0.75 mm²
No. Test Item Test Condition / Method Requirement Type
1 Conductor DC resistance GB/T 3048.4, 20 °C ≤ 26 Ω/km per conductor Routine
2 Power-frequency withstand 2.0 kV AC, 5 min No breakdown Routine
3 Insulation resistance @ 70 °C GB/T 3048.5, 70 °C ≥ 0.010 MΩ·km Routine
4 Conductor continuity Visual + electrical Both cores continuous Routine
5 Dimensional check Micrometer Insulation ≥ 0.5 mm; sheath ≥ 0.55 mm; OD ≈ 6.1 mm Routine
6 PVC insulation tensile & elongation GB/T 2951.11 Tensile ≥ 10 MPa; elongation ≥ 100 % Type
7 PVC sheath tensile & elongation GB/T 2951.11 Tensile ≥ 10 MPa; elongation ≥ 125 % Type
8 PVC heat deformation 80 °C, 4 h, load Deformation ≤ 50 % Type
9 PVC shrinkage test 150 °C, 1 h Shrinkage ≤ 4 % Type
10 Single-cable vertical flame GB/T 18380.12 Self-extinguishing; char ≤ 50 mm above burner Type
11 Bending / flexing test ≥ 6 × OD mandrel No crack in insulation or sheath Type
12 Cold bend test −15 °C, 4 h No cracking after mandrel bend Type
13 Ozone / weathering (outdoor variant) As required Per customer specification Optional
14 Voltage test after bending 2.0 kV AC, 5 min No breakdown after flexing Type
15 Marking legibility Visual + rubbing Type/voltage/supplier/metre marks legible Routine
16 Core identification Visual + continuity Correct colour-coded conductors identified Routine


Cable Cross Section Structure 


2 Core 0.75mm2 Flexible PVC Cable RVV 2x0.75mm2 For Equipment Internal Wiring

RVV 2×0.75 mm² — Cross-Section Construction Diagram (Schematic)
Layered 2-core flexible build-up from fine copper strands to PVC jacket · nominal dimensions per GB/T 5023.5 / IEC 60227-5 · finished Ø ≈ 6.1 mm per cross-referenced industry sample
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductor (Cu) × 2 Annealed copper, Class 5 flexible stranded — 26 wires of 0.19 mm per core (1+6+19 layout), nominal area 0.75 mm² each — ≈ 1.5 (Ø each conductor) Flexible line conductors; DC resistance capped at 26 Ω/km at 20 °C
2 Insulation (PVC) × 2 PVC compound, PVC/C (TI1) 0.5 ≈ 2.5 (Ø each insulated core) Electrical isolation; 70 °C continuous rating; withstands 2.0 kV for 5 min
3 Core assembly Two insulated cores laid parallel and cabled; interstices filled by sheath extrusion — ≈ 5.0 (Ø over assembled cores) Round 2-core lay-up; derived from finished Ø 6.1 − 2×0.55 sheath
4 Outer sheath (PVC) PVC compound, PVC/ST5, black or custom 0.55 ≈ 6.1 (Ø finished cable) Mechanical protection and abrasion resistance; non-flame-spreading per GB/T 18380.12
Key Dimensions & Properties (expanded)
Finished cable diameter ≈ 6.1 mm Cross-referenced industry 2-core sample

Approximate cable mass ≈ 55 kg/km Cu build-up (cross-referenced industry data)

Nominal voltage rating 300/500 V AC 50 Hz; maximum system voltage Um = 500 V

Conductor temperature limit 70 °C Continuous service

Minimum bend radius (flexible) ≥ 6 × OD ≈ 37 mm OD = actual finished cable diameter

Flame behaviour Non-flame-spreading — Per GB/T 18380.12

Conductor DC resistance ≤ 26 Ω/km At 20 °C, per GB/T 3956 Class 5

Insulation resistance @ 70 °C ≥ 0.010 MΩ·km Finished cable, minimum

Routine test voltage 2.0 kV AC / 5 min — Power-frequency withstand

AC impedance @ 50 Hz ≈ 26 Ω/km R-dominant (est.)

Capacitance (typical) ≈ 100 nF/km Per core (est.)

Air ampacity @ 25 °C ≈ 6 A Two cores loaded, Cu (est.)

Voltage drop @ 6 A ≈ 0.16 V/m Loop drop (est.)

Maximum pulling tension ≤ 30 N ≈ 20 N/mm² of total copper area (est.)

Mass per 100 m ≈ 5.5 kg/100 m For reel / carton loading

Schematic — not to exact scale. Finished Ø ≈ 6.1 mm and weight ≈ 55 kg/km from cross-referenced industry samples; conductor/insulation diameters calculated from GB/T 3956 and GB/T 5023.5; ampacity 6 A is an engineering estimate for 2-core flexible cords. Values marked (est.) require confirmation against the factory test certificate.


Construction Description


Construction Description — RVV 2×0.75 mm² 
Layer-by-layer build-up narrative, conductor through outer jacket · per GB/T 5023.5 & IEC 60227-5 · CU / PVC / PVC · 300/500 V class · finished Ø ≈ 6.1 mm (cross-referenced industry sample)
1. Product Identity & Ratings
RVV 2×0.75 is a compact two-core flexible PVC cord designed for light-duty power and signal interconnection: two 0.75 mm² annealed copper conductors, each insulated in PVC and collectively sheathed in a second PVC overjacket, rated for 300/500 V AC at 50 Hz and a 70 °C conductor temperature. It is manufactured and type-tested to GB/T 5023.5 (60227 IEC 52) / IEC 60227-5, with Class 5 flexible conductors per GB/T 3956. The finished diameter is about 6.1 mm (cross-referenced industry sample) and the nominal mass is roughly 55 kg per kilometre (≈ 5.5 kg per 100 m), supplied on 100 m reels or cartons.
With both cores energised, the cord carries about 6 A in free air at 25 °C (engineering estimate), suited to appliance leads, lamp connections, instrument wiring and low-current control circuits rather than heavy distribution feeders.
2. Flexible Copper Conductors
Each 0.75 mm² conductor is stranded from twenty-six 0.19 mm annealed wires in the 1+6+19 arrangement — the Class 5 flexible standard at this cross-section — giving a strand-lay diameter of about 1.5 mm and a DC resistance ceiling of 26 Ω/km at 20 °C (about 33 Ω/km at the 70 °C operating point). The many fine wires give the cord its flexibility and bending endurance, which is why it is preferred for appliance connections and equipment leads rather than fixed building wiring. Copper mass is about 6.7 kg/km per core, 13.4 kg/km in total.
3. PVC Insulation
PVC is extruded at 0.50 mm onto each 0.75 mm² conductor, producing approximately 2.5 mm per insulated core. The insulation is rated for 70 °C continuous duty, passes the routine 2.0 kV AC five-minute voltage proof, and maintains insulation resistance above 0.010 MΩ·km at 70 °C. Insulation colours are standardised (commonly brown/blue for 230 V mains, or red/black for DC and signal circuits) and may be specified to order.
4. Cabling & PVC Outer Sheath
After insulation, the two cores are laid parallel and cabled; the interstices are filled by the extruded sheath itself, forming a compact round bundle of about 5.0 mm diameter. A 0.55 mm layer of PVC (ST5 compound) is then extruded over the pair to the ≈ 6.1 mm finish. The jacket provides abrasion resistance and mechanical protection, and the whole cord meets the single-cable vertical flame test GB/T 18380.12. Because both insulation and sheath are halogenated PVC, the cord emits smoke and HCl in a fire; for public or confined spaces, specify a low-smoke zero-halogen variant.
5. Site Handling & Operational Notes
• Observe the 6 × OD minimum bending radius (≈ 37 mm).  • Strip 8–10 mm for termination and always use a ferrule on the flexible Class 5 strands to prevent wire fraying.  • Service ambient spans −15 to +70 °C; warm reels indoors before pulling below 0 °C.  • The 6 A reference requires derating for ambient temperature and bundling.  • Maximum pulling tension ≤ 30 N; do not use the cord as a pulling rope.  • Not for direct burial, outdoor UV exposure or continuous repetitive flexing — for those duties choose an armoured cable, UV-stabilised jacket or a continuous-flex (trunking) cable respectively.  • Use reels with flanges suited to the ≈ 6.1 mm OD.


8. Standards & Conformity. Design and production are governed by GB/T 5023.5 and IEC 60227-5 for 300/500 V flexible cords (60227 IEC 52). Conductors satisfy GB/T 3956 / IEC 60228 Class 5 — the 0.75 mm² conductor as twenty-six wires of 0.19 mm with R ≤ 26 Ω/km. Flame behaviour is proven by GB/T 18380.12. General test methods follow GB 5023.1 / GB 5023.3, while surface marking complies with GB/T 6995. Cables can also be supplied to IEC, BS, DIN, UL or VDE requirements on request. Because the PVC jacket contains halogen, tunnels, metro systems, hospitals and other confined public areas call for an LSZH variant.


9. Packaging, Storage & Logistics. Standard delivery is 100 m per reel or carton, with bespoke cut lengths available on request. Each reel carries type, voltage, supplier identity, production year and sequential metre marking per GB/T 6995. Storage should be in dry, covered premises at −15 to +40 °C, shielded from direct sunlight, moisture, oils and sharp objects; reels remain sealed until installation. In cold conditions, condition reels indoors to ≥ 0 °C before uncoiling. During transit, reels must be secured against rolling and impact, and the cord must never be dragged across abrasive ground or sharp edges.


2 Core 0.75mm2 Flexible PVC Cable RVV 2x0.75mm2 For Equipment Internal Wiring


10. Procurement Specification. State "RVV 300/500 V 2×0.75" together with the required length or reel arrangement, insulation colour combination and marking preferences. Specify the sheath colour (black is standard) and any special colour-coding (e.g. brown/blue for 230 V mains, red/black for DC). Always request the factory test certificate to confirm the actual diameter (≈ 6.1 mm), weight (≈ 55 kg/km) and conductor resistance for the production batch. Where low-smoke zero-halogen or continuous-flex construction is needed, order the LSZH or H05VV5-F variant respectively.


11. Cable Industry FAQ.

  • Q1: How does RVV differ from RVVP or RVVSP? RVV is the plain unshielded round flexible cord. RVVP adds a tinned-copper braid screen for electromagnetic interference rejection, and RVVSP additionally twists the pairs — choose these variants when the circuit carries low-level signals or is routed near noisy equipment.
  • Q2: Why a 0.75 mm² cross-section for mains leads? For a 6 A load at 230 V, 0.75 mm² is the standard minimum for appliance supply cords under IEC 60227 and GB/T 5023. Larger loads require 1.0, 1.5 or 2.5 mm² conductors.
  • Q3: What does Class 5 flexible conductor mean? Class 5 (GB/T 3956) is made of many thin wires (26 × 0.19 mm at 0.75 mm²), giving the cord its flexibility and bend endurance. Class 2 (used in power cables like YJV) uses fewer thicker wires and is much stiffer — never mix them up when ordering.
  • Q4: Can RVV be used outdoors? Not in its standard form: the PVC jacket is not UV-stabilised and will degrade under prolonged sunlight. For outdoor use specify a UV-stabilised jacket or an armoured cable. For burial, use a steel-tape armoured power cable.
  • Q5: How is the conductor cross-section chosen for an appliance lead? Selection follows (a) full-load current after derating, (b) permissible voltage drop (typically ≤ 5 % for appliance leads), and (c) coordination with the upstream fuse or circuit breaker. A 0.75 mm² cord supports up to about 6 A; higher loads require 1.0 mm² or larger.
  • Q6: Copper or tinned copper conductor? Bare annealed copper (this RVV) is standard for fixed appliance leads and gives the lowest resistance. Tinned copper is preferred where the conductor may be exposed to moisture or where solder termination is used, because it resists oxidation.
  • Q7: Why can PVC only run at 70 °C while XLPE runs at 90 °C? PVC is a thermoplastic that softens and deforms at elevated temperature; XLPE is cross-linked into a thermoset network that retains its shape up to 90 °C. This is why RVV (PVC) is limited to 70 °C and YJV (XLPE) to 90 °C.
  • Q8: What is the difference between RVV and RVB/RVS? RVV is a round sheathed cable; RVB is a flat parallel unsheathed twin cord, and RVS is a twisted pair unsheathed. The round RVV is preferred where mechanical protection or a clean outer appearance is needed.
  • Q9: Why does finished diameter vary between manufacturers for the same nominal size? Standards set minimum insulation and sheath thicknesses plus electrical performance, but not a precise overall diameter. Stranding compaction, filler design and sheath tolerance differ between plants — published 2×0.75 figures cluster around 6.1 mm — so the actual measured diameter must be used when sizing glands and clips.
  • Q10: Which tests confirm acceptability on delivery and before energisation? At delivery, verify the factory test certificate (resistance ≤ 26 Ω/km, 2.0 kV/5 min withstand, dimensions ≈ 6.1 mm), jacket legibility and reel integrity. After installation, complete an insulation-resistance test plus a 2.0 kV AC / 5 min withstand, then confirm both conductors identified correctly before energising.
  • Q11: What service life can be expected? When installed and operated within the stated temperature and voltage limits, PVC flexible cords are designed for a service life of around 10–15 years in dry indoor conditions; sustained overload, repeated flexing beyond the 6 × OD minimum radius, ultraviolet exposure, or operation above 70 °C will materially shorten that life.