logo
Anhui Tongdu International Trade Co., Ltd.
Online Service

Online Service

Contact Person
+86 19056002718
WeChat QR Code
Follow Us

Class 2 x 25mm2 2 Cores Cable Flame Retardant Copper Cable Xlpe Insulation Pvc Sheath

Class 2 x 25mm2 2 Cores Cable Flame Retardant Copper Cable Xlpe Insulation Pvc Sheath

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
ZR-YJV 2*25mm²

Trading Properties

moq
1 Meter
payment method
L/C,T/T
supply capacity
10000 meters per month

Product Summary

ZR-YJV 2*25mm² Flame Retardant Copper Cable,0.6/1kV XLPE Insulation PVC Sheath for Power Distribution Cable Designation & Meaning Code Meaning ZC Flame retardant C— IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 2×25 mm² Two cores, 25 mm² copper conductor each ...

Product Details

Highlight:

Class 2 2 Core Cable

,

25mm 2 core cable Flame Retardant

,

Power Distribution pvc cable sheath

Conductor (×2):
Bare Annealed Copper, Class 2 Stranded, 7×∅2.14 Mm, Conductor Ø ≈ 6.4 Mm
Conductor nominal area:
25 Mm²
Number of cores:
2
Conductor construction:
Class 2, 7×∅2.14 Mm,min. 7 Wires
Conductor diameter (approx.):
6.4mm
Insulation (×2):
XLPE,
Insulation thickness:
0.9 Mm (25 Mm² Class)
Diameter over insulated core:
8.2 Mm (6.4 + 2×0.9)
Filler:
Flame-retardant PP/PE To Form Round Assembly
Binder:
Flame-retardant Tape Over Laid-up Cores
Outer sheath:
Flame-retardant PVC (ZR Grade)
Sheath thickness:
1.8 Mm (multi-core Rule, ≥1.8 Mm)
Overall cable diameter:
19.0 – 19.8 Mm Use 19.4 Mm For Design
Approx. weight:
480 – 540 Kg/km Use ≈ 510 Kg/km
Long-term service temp.:
90 °C
Short-circuit temp. (≤5 s):
250°C
Emergency overload:
105–130 °C
Routine test:
3.5 KV AC / 5 Min; Type Test 4.0 KV
Volume resistivity @90 °C:
≥ 10¹² Ω·cm

Product Description

ZR-YJV 2*25mm² Flame Retardant Copper Cable,0.6/1kV XLPE Insulation PVC Sheath for Power Distribution

Cable Designation & Meaning

Code

Meaning

ZC

Flame retardant C— IEC 60332-3-24, Category C

YJ

Cross-linked polyethylene (XLPE) insulation

V

PVC sheath

2×25 mm²

Two cores, 25 mm² copper conductor each


Construction: Two Class 2 stranded copper conductors, XLPE insulation, PVC outer sheath (no armour, no shield, circular or flat formation).


Class 2 x 25mm2 2 Cores Cable Flame Retardant Copper Cable Xlpe Insulation Pvc Sheath

ZC-YJV 2×25 mm² — LV Flame-Retardant Twin-Core Power Cable — Specification

1. Overview & Ratings. ZC-YJV 2×25 is a twin-core (L + N) LV power cable rated 0.6/1 kV (Um 1.2), 90 °C working, ZC class C flame-retardant PVC sheath. Two matched compacted 25 mm² copper cores, dry-cured XLPE, unarmored. OD ≈ 13.0 mm, ≈ 560 kg/km (est.), ≈ 101 A per core free air at 30 °C (est.). Scope: 230 V sub-branches, socket ring mains, lighting/small motor feeds — not 950°C fire duty.


2. Construction Stack (Inner → Outer, expanded).


Layer / Feature Build Function
Conductor L 1×25 compacted Cu, Class 2, ≈7 strands Phase, R ≤0.741 Ω/km
Conductor N 1×25 compacted Cu, Class 2, ≈7 strands Matched neutral
Strand compaction Concentric layers rolled compact Round bundle, clean lug entry
XLPE insulation (L/N) Dry-cured PE, ≈1.2 mm per core 90°C dielectric
Core identification Color band / printed L/N Prevents crossed wiring
Twin-core laying Two cores twisted compact Stable ≈11.8 mm sub-bundle
PVC ZC sheath Class C, ≈1.3 mm overall Binds pair, self-extinguishes
Jacket print Continuous type/size/voltage/length On-site readable spec


3. Electrical Characteristics. Per-core R ≤ 0.741 Ω/km @20 °C. Test 3.5 kV AC / 5 min; ≈ 101 A per core (est., air 30 °C); short-circuit ≈ 2.4 kA / 1 s (est.); 50/60 Hz; unscreened; low-loss XLPE; high stable insulation resistance.

Insulation & Sheath Data

Property

Value

Insulation material

XLPE (cross-linked polyethylene)

Outer sheath material

PVC (ST₂)

Long-term service temp.

90 °C (continuous)

Max. conductor temp. (normal)

90 °C

Short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Test voltage AC (5 min)

3.5 kV

Dielectric strength

≥ 20 kV/mm

Volume resistivity @20 °C

≥ 1×10¹⁴ Ω·cm

Shield

None as standard (can be added)

Electrical Parameters

Parameter

Value

Note

Rated voltage U₀/U

0.6 / 1 kV

GB/T 12706.1 / IEC 60502-1

Max. system voltage

1.2 kV AC

—

Test voltage AC (5 min)

3.5 kV

Routine test

DC resistance @20 °C

≤ 0.727 Ω/km per core

GB/T 3956 Class 2 Cu max

AC resistance @90 °C (est.)

≈ 0.933 Ω/km per core

—

Current rating in air (30 °C)

Phase: 120 A​

two-core, touching, in free air

Current rating in tray (30 °C)

Phase: 135 A​

two-core, spaced 2×OD

Current rating buried in ground (20 °C, thermal resistivity 1.2 K·m/W)

Phase: 125 A​

direct buried

Current rating in conduit (30 °C)

Phase: 110 A​

—

Short-circuit current (1 s, Cu, 250 °C)

≈ 2.8 kA (2,800 A) per core

—

Capacitance (core-to-core, approx.)

≈ 0.14 µF/km

XLPE

Capacitance (core-to-sheath, approx.)

≈ 0.15 µF/km

XLPE

Inductive reactance (approx.)

≈ 0.08 Ω/km

at 50 Hz

Frequency

50/60 Hz AC

—


Reference values: 2×25 at 120 A single-phase, 230 V → max load ≈ 27 kW​ (cos φ = 0.8). Suitable for single-phase distribution, control circuits, and small equipment connections.


4. Thermal & Flame. 90 °C continuous, 250 °C short-time; ZC class C self-extinguishing — flame retardancy, not 950°C integrity; withstands repeated 0~90°C cycles; indoor; UV-grade jacket optional.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

90 °C (continuous)

Max. short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Min. installation ambient temp.

0 °C (below 0 °C requires preheating)

Service ambient range

−20 °C to +90 °C

Flexing temp. range

0 °C to +90 °C

Fire Performance (ZC-YJV — Flame Retardant C)

Property

Value / Requirement

Flame retardant

GB/T 18380.12 / IEC 60332-1-2​ (single cable, self-extinguishing)

Flame retardant class

Class C​ (ZC) per GB/T 19666

Halogen content

Contains halogen (PVC sheath)

Smoke density

Not low-smoke (PVC)

Corrosivity

Corrosive (PVC)

Toxicity

Toxic fumes when burned (PVC)

EMI shielding

None (no metallic screen/armour)


5. Installation Practice & Handling. 25 mm² Cu lugs, small glands, crimp/torque per table; bend ≥ 15×OD ≈ 195 mm; derate bundled/conduit runs; avoid pinching the twin bundle; continuity + insulation per core after pulling.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 15 × OD → ≈ 233 mm at Ø15.5 mm

two-core unarmoured

Max. pulling tension

375 N per core (25 mm² × 15 N/mm²)

Cu conductor limit

Direct burial

Suitable (with sand bedding)

—

Surface mounting

Excellent (cable tray, ladder, cleats)

—

Conduit ID

≥ 20 mm

—

Fixing

cable ties, cleats

—

Impact resistance

Moderate

—

Water resistance

Good (PVC sheath)

—

UV resistance

Fair (PVC degrades outdoors, use UV-resistant PVC or conduit)

—

Flex life

Good (Class 2 stranded)

fixed installation

Termination note

Standard compression lugs or mechanical connectors

—


6. Typical Service Applications. 230 V socket outlet ring mains, lighting sub-branches and luminaire circuits, small motor and auxiliary power leads, distribution to local load groups, light commercial branch wiring.

Class 2 x 25mm2 2 Cores Cable Flame Retardant Copper Cable Xlpe Insulation Pvc Sheath


7. Testing & QA Regime (16 items). Routine: DC resistance L/N, 3.5 kV withstand, insulation resistance, continuity, sheath/insulation thickness, dimensional check, strand construction, eccentricity, appearance, print legibility, mass. Type: ZC flame test, short-circuit rating, sheath mechanical, 0~90°C cycle.


Cable Parameters


ZC-YJV 2×25 mm² — LV Flame-Retardant Twin-Core Power Cable — Full Parameter Sheet 
2×Cu / XLPE / PVC · ZC class C · 0.6/1 kV · ≈13.0 mm · phase + neutral twin-core for 230V sub-branches, socket ring mains, lighting feeds & small motor circuits
Parameter Value Unit Remarks / Standard
01 · Identification
Cable type ZC-YJV — Cu/XLPE/PVC, flame-retardant class C — ZC-YJV denotes a copper-conductor cable with cross-linked polyethylene insulation and a PVC outer sheath; the leading ZC marks a Chinese flame-retardant class C compound that self-extinguishes after the ignition source is removed.
Rated voltage (U0/U) 0.6/1 kV 0.6 kV phase-to-earth (U0) and 1 kV phase-to-phase (U) rating defines this as a general low-voltage power cable suited to 230/400 V building distribution.
Maximum operating voltage (Um) 1.2 kV The 1.2 kV maximum system voltage is the continuous upper phase-to-earth limit the XLPE insulation may withstand in normal service.
Core configuration 2×25 (L + N) — Two equal 25 mm² compacted copper cores twisted together — one phase (L) and one neutral (N) — for single-phase 230 V sub-branches, socket rings and small motor/lighting feeds.
Conductor material Compacted stranded annealed copper — Soft annealed copper strands are layer-compacted into a round bundle to lower skin effect, reduce diameter and give a clean entry into a 25 mm² lug.
Insulation XLPE cross-linked polyethylene — Chemically cross-linked polyethylene bonds into a heat-resistant dielectric that keeps its properties at the 90 °C operating temperature.
Sheath PVC, flame-retardant class C (ZC) — An overall PVC jacket protects the twisted cores from abrasion and dust and carries the class C flame-retardant formulation; deep slate blue-gray finish.
Flame retardancy ZC class C (self-extinguishing, not fire-rated) — On removal of a flame the cable stops propagating fire; this is flame-retardancy, not 950 °C/180 min circuit-integrity fire resistance.
Suitable for Fixed indoor tray, conduit, trunking, sub-branch — Designed for fixed mid-light single-phase wiring: socket ring mains, lighting sub-branches and small motor circuits.
Application 230V sub-branch, socket ring, lighting feed — Typically runs a phase-and-neutral feed from a sub-board to socket rings, lighting points or a small motor.
Application note Not for 950°C circuit-integrity fire duty — Do not substitute this ZC cable for a mineral-insulated or fire-resistant circuit; it cannot maintain live integrity under sustained fire.
02 · Conductors
Power core count / area 2 × 25 mm² Two identical 25 mm² conductors provide balanced phase and neutral paths for single-phase sub-branch power.
Conductor type Compacted stranded Cu, Class 2 — Class 2 stranded compacted construction gives a fixed-wiring conductor that rounds into a stable bundle for clean lug termination.
DC resistance (25) @ 20°C ≤ 0.741 Ω/km Maximum permitted DC resistance of a 25 mm² copper conductor at 20 °C; watch voltage drop on longer socket-ring branches.
Stranding Layer-compacted concentric bundle — Concentric layers of strands are compacted radially to reduce gaps, tighten the bundle and present a clean round entry into the lug.
Strands (nom., est.) ≈ 7 compacted — Approximate number of compacted strands in a 25 mm² Class 2 bundle; exact count follows the conductor standard and factory drawing.
Surface Bare copper; tinned optional — Bare copper suits most indoor use; optional tinned plating improves corrosion resistance in damp sites.
Core identification L phase / N neutral by color or marking — Cores are distinguished by insulation color or printed marking so phase and neutral are wired consistently at both ends.
Nominal area tolerance Within conductor class 2 band — Actual cross-sectional area and strand geometry stay inside the class 2 tolerance band rather than a solid bare count.
03 · Insulation
Insulation material XLPE (cross-linked polyethylene) — Cross-linked PE delivers a higher continuous temperature rating and lower dielectric loss than ordinary PVC insulation for the same size.
Insulation thickness (nom.) ≈ 1.2 mm Nominal radial insulation wall on each core; gauged to withstand the 3.5 kV routine test and the 90 °C heat load.
Working conductor temp. 90 °C Maximum continuous conductor temperature under rated current without shortening insulation life.
Short-circuit temp. 250 °C Peak conductor temperature the insulation may survive for a short fault duration (seconds) before damage occurs.
Insulation resistance High and stable MΩ·km XLPE keeps a high, stable insulation resistance over life, supporting reliable earth-fault detection on branch circuits.
Color Phase / neutral color on request — Insulation colors are matched to local wiring convention (e.g. brown/blue) or supplied natural with printed marking.
Cure type Chemical / dry-cured XLPE — A controlled cross-linking cure locks the polymer network so the insulation stays elastic rather than melting under heat.
04 · Sheath & Flame Retardancy
Sheath material PVC, flame-retardant ZC — The class C PVC outer jacket blends a flame-suppressing formulation while keeping a smooth, printable surface.
Sheath thickness (nom.) ≈ 1.3 mm Nominal overall jacket wall sized to shield the two twisted cores from abrasion, dust and occasional moisture.
Finished outer diameter ≈ 13.0 mm Overall twin-core finished diameter used to size trunking fill, conduit and gland entry.
Flame behavior Self-extinguishing, class C — After the test flame is removed the sample extinguishes without propagating along the cable; it is not 950°C fire-rated.
Sheath color Deep slate blue-gray (black/gray on request) — Standard deep slate blue-gray; black or dark gray jackets are supplied for outdoor and industrial aesthetics on request.
Surface finish Smooth, continuous print — A smooth jacket carries a continuous printed line of type, size, voltage, ZC class and meter length along its length.
05 · Electrical
Rated voltage (U0/U) 0.6/1 kV Low-voltage rating matching 230/400 V distribution systems.
Max voltage (Um) 1.2 kV Continuous upper system voltage for phase-to-earth insulation stress.
Nominal current (per 25 core, est.) ≈ 101 A Approximate ampacity of a single 25 mm² core in free air at 30 °C; reduce for bundling, duct fill and high ambient.
Test voltage (AC) 3.5 kV / 5 min — Routine dielectric withstand applied between conductor and sheath for five minutes without breakdown.
Insulation resistance High, XLPE MΩ·km Measured after conditioning; confirms no void, crack or contamination in the cured insulation.
Short-circuit current (25, 1s, est.) ≈ 2.4 kA Approximate 1-second copper short-time withstand; the branch core trips under a moderate fault.
Frequency 50 / 60 Hz Compatible with both 50 Hz and 60 Hz low-voltage power systems.
Dielectric XLPE, low loss — Low dielectric loss keeps heating down under continuous branch load.
06 · Thermal & Environment
Normal conductor temp. 90 °C Sustained operating temperature the XLPE insulation is rated for under full load.
Installed ambient 0 ~ +40 °C Recommended continuous ambient around the cable; higher rooms require ampacity derating.
Min install temp. 0 °C Avoid cold bending below 0 °C where the PVC jacket and insulation may stiffen and crack.
Burning Self-extinguishing, ZC class C — Class C vertical flame test behavior: flame stops once the external burner is removed.
Outdoor / UV Indoor preferred; UV-grade jacket optional — Standard PVC degrades under prolonged direct sun; specify UV-stabilized jacket for exposed outdoor runs.
Oil / chemicals Resistant to common oils; check aggressive media — Withstands typical machine oils; verify against specific solvents or acid fumes before use.
Temperature cycle Withstands repeated 0~90°C duty — The insulation and jacket survive repeated heating/cooling cycles without cracking or delamination.
07 · Mechanical & Construction
Min bending radius (fixed) ≥ 15 × OD ≈ 195 mm Fixed-installation minimum bend radius for the twin-core cable; tighter bends strain insulation and jacket.
Flexibility Stranded, easy to pull on site — Compacted strands keep the cable flexible enough to route through trunking and conduit.
Shielding / Armor None / unarmored — No copper braid screen and no armor; add screening or armor where EMI or mechanical protection is required.
Cable weight per km (est.) ≈ 560 kg/km Approximate mass per kilometer used for tray loading and drum/coil sizing.
Circularity Compacted twin bundle, stable OD — The two cores lay into a compact bundle so the finished OD stays consistent along the length.
Tensile / elongation Jacket meets PVC grade — Sheath tensile strength and elongation satisfy the PVC compound grade for durable handling.
08 · Factory Advantages
Matched twin cores L and N built to the same 25 mm² spec for balanced sub-branches — Both cores match in size and resistance so phase and neutral drop equally along a socket ring.
Stable XLPE cure Even cross-linking keeps the 90°C dielectric consistent lot to lot — Controlled cure removes soft spots in insulation that would age faster under branch load.
Dosed ZC compound Flame-retardant PVC self-extinguishes to class C — Dosed flame inhibitors give a safety margin against incidental ignition in wiring spaces.
Length-on-demand Cut to exact meter, sealed ends, minimal offcut — Custom cut lengths match the measured branch run and reduce waste.
Batch resistance log Per-core DC R recorded against the lot number — Each core's resistance is logged against batch ID for procurement traceability.
Continuous print line Type, size, ZC, voltage and meter length along jacket — Clear continuous marking lets installers read the spec without a certificate on site.
Phase-color option L/N insulation colors matched to local convention — Pre-colored phase and neutral remove guesswork at termination and inspection.
Drum or coil pack Supplied on drum or coil to match the branch — Choose a coil for shorter runs or a drum for longer branch pulls.
Certified QA pack Routine + type test record shipped per batch — A complete QA packet supports buyer audit and commissioning sign-off.
09 · Installation
Laying Tray, conduit, trunking, sub-branch — Route in fixed supports; avoid pinching the twin bundle and keep bending above 15×OD.
Connectors 25 mm² Cu lugs, small glands — Crimp matched 25 mm² copper lugs on each core; select a gland sized to the 13.0 mm OD.
Bend radius ≥ 15×OD ≈ 195 mm — Maintain the minimum radius around corners to prevent insulation cold-working.
Parallel runs Derate when bundled in conduit/tray — Adjacent heating cores share heat; apply bundle derating before sizing the branch breaker.
Site test Continuity + insulation post-laying — After pulling, verify L and N continuity and insulation resistance before energizing.
Termination Strip, crimp lug, torque per table — Strip insulation without nicking strands, crimp the lug fully, and torque per the lug table.
10 · Packing & Applications
Supply length Custom / drum or coil m Cut to the measured branch length; drum or coil packing.
Length tolerance Per trade standard for cut lengths — Cut-length tolerance follows the applicable trade standard rather than a fixed meter promise.
Reel type Wooden drum / coil — Drum for long pulls; coil for shorter branches.
Surface marking ZC-YJV, 2×25, 0.6/1kV, ZC, length — Jacket prints type, two-core size, voltage, flame class and cumulative meter length.
Typical use Sub-branch, socket ring, lighting feed — Runs phase+neutral to socket rings, lighting points and small motors.
Storage Dry indoor, avoid direct UV — Store on a pallet, dry and shaded, to keep the jacket intact.


Cable Test Parameters


Test Parameters — ZC-YJV 2×25 LV Flame-Retardant Twin-Core Cable
No. Test Item Test Condition / Method Requirement Type
1 Conductor DC resistance 20 °C, each core L and N 25 ≤0.741 Ω/km Routine
2 Voltage test (AC) 3.5 kV AC, 5 min, core-to-sheath No breakdown Routine
3 Insulation resistance XLPE, 20°C, per core High & stable Routine
4 Continuity Each core L and N Continuous Routine
5 Flame retardancy Class C vertical test Self-extinguish Type
6 Sheath thickness Micrometer, cross-section Nominal ≥1.3 mm Routine
7 Insulation thickness Micrometer, per core Nominal ≥1.2 mm Routine
8 Dimensional check Caliper, overall OD OD ≈ 13.0 mm Routine
9 Conductor construction Visual / strand count Class 2 compacted Routine
10 Short-circuit rating Calculated / type 2.4 kA / 1 s Type
11 Insulation eccentric test Cross-section measure per core Within tolerance Routine
12 Sheath appearance Visual along length Smooth, no flaw Routine
13 Printing legibility Visual Marking readable Routine
14 Mass per unit length Weigh / calculate ≈ 560 kg/km Routine
15 Sheath mechanical Tensile / elongation check Meets PVC grade Type
16 Temperature cycle Repeated 0~90°C duty No cracking Type


Cable Cross Section Structure


Class 2 x 25mm2 2 Cores Cable Flame Retardant Copper Cable Xlpe Insulation Pvc Sheath

ZC-YJV 2×25 — Twin-Core Cross-Section Construction Diagram (Schematic, Expanded)
2×Cu core / XLPE insulation / PVC ZC sheath · 0.6/1 kV · ZC class C · ≈13.0 mm · L+N sub-branches, socket ring mains & small motor/lighting feeds
No. Layer / Feature Material / Construction Nominal Thickness (mm) Diameter (mm) Detailed Function / Remarks
1 Conductor (L) — phase 1×25 compacted Cu, Class 2, ≈7 strands — ≈ 7.1 Phase core, DC R ≤0.741 Ω/km @20°C; watch drop on long ring runs.
2 Conductor (N) — neutral 1×25 compacted Cu, Class 2, ≈7 strands — ≈ 7.1 Matched neutral core, same size/resistance to balance single-phase drop.
3 Strand compaction Concentric layers rolled compact — — Radial compaction closes strand gaps for a round bundle and clean lug entry.
4 XLPE insulation (L) Dry-cured cross-linked PE ≈ 1.2 ≈ 9.5 90°C dielectric on the phase core, low loss, high stable insulation resistance.
5 XLPE insulation (N) Dry-cured cross-linked PE ≈ 1.2 ≈ 9.5 Matching neutral insulation; L/N distinguished by color or print.
6 Core identification Color band or printed L/N marking — — Phase and neutral readable at both ends to prevent crossed wiring.
7 Twin-core laying Two cores twisted into a compact bundle — ≈ 11.8 Controlled lay keeps the pair stable and reduces OD for trunking fill.
8 PVC ZC sheath Flame-retardant class C, smooth, overall ≈ 1.3 ≈ 13.0 Binds the pair, shields from abrasion/dust, self-extinguishes to class C.
9 Jacket print Continuous type/size/voltage/length line — — Marking along the jacket: ZC-YJV, 2×25, 0.6/1kV, ZC, cumulative length.
Key Dimensions, Electrical & Mechanical Properties (expanded)
Finished cable diameter ≈ 13.0 mm Twin-core overall OD for trunking and small gland sizing.
Approx. cable mass (est.) ≈ 560 kg/km Light bundle, easy to pull and coil.
Nominal voltage rating 0.6/1 kV Matches 230/400 V distribution systems.
Max voltage (Um) 1.2 kV Phase-to-earth continuous upper limit.
Normal conductor temp. 90 °C Continuous load temperature of XLPE.
Short-circuit temp. 250 °C Short-time fault peak before insulation damage.
DC resistance (25) ≤ 0.741 Ω/km Per core @20°C; watch drop on long rings.
Nominal current (est.) ≈ 101 A Per core, free air 30°C; derate bundled.
Short-circuit rating (1s, est.) ≈ 2.4 kA 25 Cu, branch fault duty.
Flame retardancy ZC class C, self-extinguishing — Not 950°C fire-rated.
Min bending radius (fixed) ≥ 15 × OD ≈ 195 mm Fixed twin-core install corner radius.
Frequency 50 / 60 Hz Compatible with both power systems.
Insulation resistance High & stable MΩ·km XLPE; supports earth-fault detection.
Dielectric loss Low — XLPE keeps heating down on continuous load.
Temperature cycle 0~90°C repeated — Survives heating/cooling without cracking.
Sheath mechanical Meets PVC grade — Tensile/elongation checked at type test.
Pack choice Drum or coil — Coil for branches, drum for long pulls.
Core configuration 2×25 (L+N) — Balanced twin single-phase.
Application Sub-branch, socket ring, lighting feed — 230 V branch power.
UV / outdoor UV-grade optional — Indoor preferred; specify stabilized jacket outside.
Schematic — not to exact scale. OD ≈13.0 mm, weight ≈560 kg/km, ≈101 A per core free air at 30°C and ≈2.4 kA/1s are (est.) from cross-referenced industry samples. ZC-YJV 2×25 serves 230 V sub-branches, socket ring mains and small motor/lighting feeds; ZC class C self-extinguishes but is not 950°C fire-rated. Estimated values require confirmation against the factory test certificate for the specific batch.


Cable Construction Description


Construction Description — ZC-YJV 2×25 LV flame-retardant twin-core cable 
2×Cu core / XLPE insulation / PVC ZC sheath · 0.6/1 kV · ZC class C · 90°C · ≈13.0 mm · L+N sub-branches, socket ring mains & small motor/lighting feeds
1. Product Identity & Ratings
ZC-YJV 2×25 rated 0.6/1 kV (Um 1.2), 90°C working, ZC class C; twin L+N cores. OD ≈13.0 mm, ≈560 kg/km (est.), ≈101 A per core free air at 30°C (est.), drum or coil. It is a fixed sub-branch / socket-ring cable, not a flexible cord and not a 950°C fire-rated circuit.
2. Copper Conductors (2×25)
Two matched 25 mm² compacted Class 2 Cu cores (L + N), ≈7 strands each; DC R ≤0.741 Ω/km @20°C; balanced branch current; tinned plating optional for damp sites; phase-color insulation supplied on request.
3. Strand Compaction & Bundle
Concentric strands are rolled compact to close gaps, round the bundle and give a clean entry into a 25 mm² lug; the two cores are twisted at a controlled lay to hold a stable ≈11.8 mm sub-bundle before sheathing.
4. XLPE Insulation
Dry-cured cross-linked PE ≈1.2 mm on each core, stable 90°C dielectric, low dielectric loss, high and stable insulation resistance; short-circuit peak 250°C; L/N distinguished by color or printed marking.
5. Core Identification
Phase (L) and neutral (N) are identified by insulation color band or printed marking so wiring matches at both ends; brown/blue colors can be supplied to local convention instead of natural insulation.
6. PVC ZC Sheath
Flame-retardant PVC ≈1.3 mm overall, self-extinguishing class C; deep slate blue-gray standard (black/gray on request); smooth printable surface; binds the pair and shields from abrasion, dust and occasional moisture.
7. Electrical Characteristics
0.6/1 kV, Um 1.2; per-core R ≤0.741 Ω/km; routine 3.5 kV AC/5 min; ≈101 A per core (est., air 30°C); short-circuit ≈2.4 kA/1s (est.); 50/60 Hz; unscreened; low-loss XLPE.
8. Factory Advantages
• Matched twin cores for balanced sub-branches.  • Stable XLPE cure lot to lot.  • Dosed ZC self-extinguish.  • Length-on-demand.  • Per-batch resistance log.  • Continuous clear print.  • Phase-color option.  • Drum or coil pack.  • Certified QA pack.
9. Site Handling & Installation
• Bend 15×OD (≈195 mm).  • 25 Cu lugs, small glands, torque per table.  • Derate bundled/conduit runs.  • Avoid pinching the twin bundle.  • Continuity + insulation per core after pulling.  • Indoor; UV grade if exposed.
10. Typical Service Applications
230 V socket outlet ring mains, lighting sub-branches and luminaire circuits, small motor and auxiliary power leads, distribution to local load groups, light commercial branch wiring.
11. Testing & QA
16-item regime: routine DC resistance L/N, 3.5 kV withstand, insulation resistance, continuity, sheath/insulation thickness, dimensional check, strand construction, eccentricity, appearance, print legibility, mass; type ZC flame, short-circuit, sheath mechanical, 0~90°C cycle.
12. Packaging, Storage & Notes
Cut to measured length on drum or coil; continuous marking; store dry indoor on a pallet, shaded, avoid direct UV. Est. OD/weight/ampacity/short-circuit confirmed against the factory certificate; ZC is flame retardant, not 950°C fire-rated.


ZC-YJV 2×25 mm² Power Cable
Frequently Asked Questions (FAQ)
Flame-Retardant Class C · XLPE Insulated · PVC Sheathed · Copper Conductor · 0.6/1 kV

Product Basics

Q1. What does the model “ZC-YJV” mean?
“Z” stands for flame-retardant, “C” denotes Class C flame-retardant performance, “YJ” means XLPE (cross-linked polyethylene) insulation, and “V” means PVC sheath. ZC-YJV is a copper-core, Class C flame-retardant, XLPE-insulated, PVC-sheathed low-voltage power cable.
Q2. What does “2×25 mm²” indicate?
“2” means the cable has two cores (two insulated conductors within a common sheath). “25 mm²” is the nominal cross-sectional area of each copper conductor. This 2-core size is commonly used for single-phase power supply circuits with moderate current demand, such as building branch feeders and single-phase equipment connections.
Q3. What is the rated voltage?
The rated voltage U₀/U is 0.6/1 kV (0.6 kV phase-to-earth, 1 kV phase-to-phase), designed for low-voltage power distribution systems.
Q4. What materials are used in construction?
Conductor: plain copper, Class 2 stranded. Insulation: cross-linked polyethylene (XLPE) on each core. Filler: non-hygroscopic material. Outer sheath: flame-retardant PVC. Standard ZC-YJV is unarmored. For direct burial, armored variants such as ZC-YJV22 (steel tape armor) are available.

Technical Specifications

Q5. What is the maximum operating temperature?
The maximum continuous conductor temperature is 90 °C. During short-circuit events, the conductor may reach up to 250 °C for no more than 5 seconds. XLPE insulation provides superior thermal performance and higher current-carrying capacity compared with PVC-insulated cables.
Q6. What is the typical current-carrying capacity?
For a 2×25 mm² copper XLPE cable, the ampacity is approximately 95–115 A when installed in free air at 30 °C ambient. Multi-core cables have slightly lower ampacity than equivalent single-core cables due to mutual heating between cores. Lower ratings apply when buried, installed in conduit, grouped, or at higher ambient temperatures. Refer to GB/T 16895 / IEC 60364 and manufacturer ampacity tables for precise engineering values.
Q7. What is the conductor DC resistance?
The maximum DC resistance of a 25 mm² Class 2 copper conductor at 20 °C is approximately 0.741 Φ/km (annealed copper), per GB/T 3956 / IEC 60228. Each core in the 2-core cable has the same resistance. Confirm the exact value from the factory test report for each batch.

Installation & Applications

Q8. What is the minimum bending radius?
For multi-core unarmored cables, the minimum bending radius is 15 times the cable outer diameter (15D) during installation. Multi-core cables are generally more flexible than single-core cables of equivalent conductor cross-section. D = actual outer diameter.
Q9. What are the typical applications?
Common uses include: single-phase power branch circuits in commercial and residential buildings; power supply to small-to-medium motors, water pumps, and HVAC units; distribution board outgoing feeders for single-phase loads; and secondary power distribution in industrial facilities where Class C flame-retardant performance is required.
Q10. Which standards and certifications apply?
Manufactured in accordance with GB/T 12706 (equivalent to IEC 60502), with conductor compliance to GB/T 3956 / IEC 60228 and flame-retardant testing per GB/T 18380 / IEC 60332-3. Common certifications include CCC (China), CE (Europe), ISO 9001, RoHS, and VDE/TUV for specific international markets.