Low Voltage Power Cable

Quality 1x16mm2 Single Core Electrical Cable Oxygen Free Self Extinguishing 1 Core 16mm Cable factory

1x16mm2 Single Core Electrical Cable Oxygen Free Self Extinguishing 1 Core 16mm Cable

ZR-YJV 1*16mm² Flame Retardant Single Core Power Cable, 0.6/1kV, Oxygen-Free Copper, XLPE Insulation, PVC Sheath, Self-extinguishing, for Indoor Building Power Distribution. Code Mean: ZR-Flame Retardant YJ-XLPE Insulation V-PVC Outer Sheathed Flame-retardant copper-conductor, XLPE-insulated, PVC...

Quality 0.6/1kV ZC-YJV 5x16mm²‌ Copper XLPE PVC Flame-Retardant Power Cable for Residential Main Distribution factory

0.6/1kV ZC-YJV 5x16mm²‌ Copper XLPE PVC Flame-Retardant Power Cable for Residential Main Distribution

0.6/1kV ZC-YJV 5x16mm²‌ Copper XLPE PVC Flame-Retardant Power Cable for Residential Main Distribution Technical Datasheet — ZC-YJV 0.6/1 kV 5×16 mm² 1. Cable Designation & Meaning Code Meaning ZC ​ Flame retardant, Class C ​ (bundled combustion test per GB/T 18380.3 / GB/T 19666) YJ ​ XLPE (cross...

Quality 0.6/1kV ZC-YJV 3x70+1x35mm²‌ Copper XLPE PVC Flame-Retardant Power Cable for Transformer Room LV Outgoing Circuits factory

0.6/1kV ZC-YJV 3x70+1x35mm²‌ Copper XLPE PVC Flame-Retardant Power Cable for Transformer Room LV Outgoing Circuits

0.6/1kV ZC-YJV 3x70+1x35mm²‌ Copper XLPE PVC Flame-Retardant Power Cable for Transformer Room LV Outgoing Circuits Technical Datasheet — ZC-YJV 0.6/1 kV 3×70+1×35 mm² 1. Cable Designation & Meaning Code Meaning ZC ​ Flame retardant, Class C ​ (bundled combustion test per GB/T 18380.3 / GB/T 19666) ...

Quality Low Voltage 2 Cores Cable 2 X 10mm2 Stranded Copper Fire Resistant PVC Insulated Sheathed factory

Low Voltage 2 Cores Cable 2 X 10mm2 Stranded Copper Fire Resistant PVC Insulated Sheathed

Low Voltage Power Cable 0.6/1kv YJV-2*10mm² Stranded Copper XLPE Insulation Fire-Resistant PVC Outer Sheath Technical Datasheet — ZC-YJV 0.6/1 kV 2×10 mm² 1. Cable Designation & Meaning Code Meaning ZC​ Flame retardant, Class C​ (bundled combustion test per GB/T 18380.3 / GB/T 19666) YJ​ XLPE (cross...

Quality 0.6/1kV 3 Cores Cable 3x16mm2 Stranded Copper Conductor XLPE Insulation PVC Outer Sheath factory

0.6/1kV 3 Cores Cable 3x16mm2 Stranded Copper Conductor XLPE Insulation PVC Outer Sheath

0.6/1kV ZC-YJV 3x16mm² Stranded Copper Conductor XLPE Insulation PVC Outer Sheath Low Voltage Power Cable Technical Datasheet — ZC-YJV 0.6/1 kV 1×16 mm² 1. Cable Designation & Meaning Code Meaning ZC​ Flame retardant, Class C (bundled combustion test) YJ​ XLPE (cross-linked polyethylene) insulation ...

Quality 1x185mm2 Single Core Cable Stranded Copper Conductor Pvc Sheath Fire Resistant C Level factory

1x185mm2 Single Core Cable Stranded Copper Conductor Pvc Sheath Fire Resistant C Level

0.6/1kV ZC-YJV 1x185mm² Stranded Copper Conductor XLPE Insulation PVC Outer Sheath Fire Resistant C Level Technical Datasheet — ZC-YJV 0.6/1 kV 1×185 mm² 1. Cable Designation & Meaning Code Meaning ZC​ Flame retardant, Class C (bundled combustion test) YJ​ XLPE (cross-linked polyethylene) insulation ...

Quality WDZBN-YJY 5 Core 3x50mm²+2x25mm² Low Smoke Halogen Free Fire Resistant XLPE Cable 0.6/1kV factory

WDZBN-YJY 5 Core 3x50mm²+2x25mm² Low Smoke Halogen Free Fire Resistant XLPE Cable 0.6/1kV

WDZBN-YJY 5 Core 3x50mm²+2x25mm² Low Smoke Halogen Free Fire Resistant XLPE Cable 0.6/1kV Cable Designation & Meaning Code Meaning 0.6/1 kV Rated voltage: U₀ = 0.6 kV (phase-to-earth), U = 1 kV (phase-to-phase) WD Low-smoke, zero-halogen (LSZH) ZB Flame retardant Category B (IEC 60332-3-23, Class B) ...

Quality ZC-YJV 4x50mm² Class C Flame Retardant XLPE Copper Power Cable for Building Distribution factory

ZC-YJV 4x50mm² Class C Flame Retardant XLPE Copper Power Cable for Building Distribution

ZC-YJV 4x50mm² Class C Flame Retardant XLPE Copper Power Cable for Building Distribution Cable Designation & Meaning Code Meaning ZC Flame retardant Category C​ (GB/T 18380.3) YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath 4×50 mm² Four cores, each 50 mm² copper (3 phases + 1 ...

Quality Heavy Gauge 4+1 Core Cable ZR-YJV 4x240mm²+1x120mm² XLPE Copper Flame Retardant factory

Heavy Gauge 4+1 Core Cable ZR-YJV 4x240mm²+1x120mm² XLPE Copper Flame Retardant

Heavy Gauge 4+1 Core Cable ZR-YJV 4x240mm²+1x120mm² XLPE Copper Flame Retardant Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath — ...

Prev 4 5 6 7 8 Next