0.6/1kV ZC-YJV 3x70+1x35mm²‌ Copper XLPE PVC Flame-Retardant Power Cable for Transformer Room LV Outgoing Circuits

0.6/1kV ZC-YJV 3x70+1x35mm²‌ Copper XLPE PVC Flame-Retardant Power Cable for Transformer Room LV Outgoing Circuits

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
ZC-YJV 3x70+1x35mm²‌

Trading Properties

moq
100 meters
payment method
L/C,T/T
supply capacity
100000 meters per month

Product Summary

0.6/1kV ZC-YJV 3x70+1x35mm²‌ Copper XLPE PVC Flame-Retardant Power Cable for Transformer Room LV Outgoing Circuits Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 3×70 mm² + 1×35 mm² Three phase ...

Product Details

Highlight:

1kv 4 cores cable

,

1kv 25 sq mm 4 core cable

,

copper 4 cores cable

Phase conductors (×3):
Bare Annealed Copper, Class 2 Stranded Compacted Circular, 19×∅2.14 Mm​
Neutral conductor (×1)​:
Bare Annealed Copper, Class 2 Stranded, 7×∅2.52 Mm​
Conductor screen:
Not Required For 0.6/1 KV; Omitted
Insulation (×4)​:
XLPE Compound
Phase cores (70 mm²):
Nominal Thickness 1.4 Mm​ (GB/T 12706, 70–95 Mm² Class)
Neutral core (35 mm²):
Nominal Thickness 1.0 Mm​ (GB/T 12706, 35–50 Mm² Class)
Filler:
Flame-retardant Non-hygroscopic PP/PE Filler​ (ZC Grade) To Form Round Assembly
Binder:
Flame-retardant Glass-fibre / FR Tape​ (ZC Grade) Over Laid-up Cores
Outer sheath:
Flame-retardant PVC​ Compound (ZC Grade)
Sheath thickness:
1.9 Mm​ (multi-core, 35 Mm² And Above, 2–5 Cores)
Conductor construction (70 mm²):
19×∅2.14 Mm
Conductor construction (35 mm²):
7×∅2.52 Mm
Diameter over phase core (approx.):
12.8 Mm
Diameter over neutral core (approx.):
9.0 Mm
Sheath nominal thickness:
1.9 Mm
Overall cable diameter:
35.2 – 38.0 Mm
Approx. weight:
3009 – 3520 Kg/km

Product Description

0.6/1kV ZC-YJV 3x70+1x35mm²‌ Copper XLPE PVC Flame-Retardant Power Cable for Transformer Room LV Outgoing Circuits

Cable Designation & Meaning

Code

Meaning

ZC

Flame retardant Class C

YJ

Cross-linked polyethylene (XLPE) insulation 

V

Polyvinyl chloride (PVC) sheath 

3×70 mm² + 1×35 mm²

Three phase cores of 70 mm² + one neutral core of 35 mm² copper conductor


Construction: Three 70 mm² copper conductors (phase) + one 35 mm² copper conductor (neutral), XLPE insulation, PVC outer sheath. No metallic screen/armour as standard (can be added on request).

0.6/1kV ZC-YJV 3x70+1x35mm²‌ Copper XLPE PVC Flame-Retardant Power Cable for Transformer Room LV Outgoing Circuits

ZC-YJV 3×70+1×35 mm² — LV Flame-Retardant 3+1 Power Cable — Specification

1. Overview & Ratings. ZC-YJV 3×70+1×35 is a 3+1 LV distribution cable rated 0.6/1 kV (Um 1.2), 90 °C working, ZC class C PVC sheath: three 70 mm² compacted copper phase cores plus one 35 mm² reduced neutral, dry-cured XLPE, unarmored. OD ≈ 23 mm, ≈ 2900 kg/km (est.), ≈ 175 A per phase free air at 30 °C (est.). Scope: 380/400 V medium motors, compressors and workshop sub-feeders — not 950°C fire duty.


2. Construction Stack (Inner → Outer, expanded).


Layer / Feature Build Function
Phase conductors L1/L2/L3 3×70 compacted Cu, Class 2, ≈19 strands R ≤0.268 Ω/km
Neutral conductor N 1×35 compacted Cu, Class 2, ≈7 strands R ≤0.524 Ω/km
Strand compaction Concentric layers rolled compact per core Compact bundle, clean lugs
XLPE insulation (phase / neutral) Dry-cured PE, ≈1.8 / ≈1.6 mm Matched 90°C dielectric
3+1 core laying 3 phases around 1 reduced neutral Stable round bundle
PVC ZC sheath Class C, ≈1.6 mm overall Self-extinguishes, prints clear
Jacket print Continuous type/size/voltage/length On-site readable spec


3. Electrical Characteristics. Phase R ≤ 0.268 Ω/km; neutral R ≤ 0.524 Ω/km @20 °C. Test 3.5 kV AC / 5 min; ≈ 175 A per phase (est., air 30 °C); short-circuit ≈ 7.0 kA / 1 s (est.); 50/60 Hz; unscreened; low-loss XLPE; high stable insulation resistance.

Insulation & Sheath Data

Property

Value

Insulation material

XLPE (cross-linked polyethylene)

Outer sheath material

PVC (ST₂)

Long-term service temp.

90 °C (continuous)

Max. conductor temp. (normal)

90 °C

Short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Test voltage AC (5 min)

3.5 kV

Dielectric strength

≥ 20 kV/mm

Volume resistivity @20 °C

≥ 1×10¹⁴ Ω·cm

Shield

None as standard (can be added)

Electrical Parameters

Parameter

Value

Note

Rated voltage U₀/U

0.6 / 1 kV

GB/T 12706.1 / IEC 60502-1

Max. system voltage

1.2 kV AC

—

Test voltage AC (5 min)

3.5 kV

Routine test

DC resistance @20 °C (phase)

≤ 0.268 Ω/km per core

GB/T 3956 Class 2 Cu max (70 mm²)

DC resistance @20 °C (neutral)

≤ 0.524 Ω/km per core

GB/T 3956 Class 2 Cu max (35 mm²)

AC resistance @90 °C (est., phase)

≈ 0.343 Ω/km per core

—

AC resistance @90 °C (est., neutral)

≈ 0.671 Ω/km per core

—

Current rating in air (30 °C)

3-phase: 210 A​

3×70+1×35, touching, in free air

Current rating in tray (30 °C)

3-phase: 230 A​

3×70+1×35, spaced 2×OD

Current rating buried in ground (20 °C, thermal resistivity 1.2 K·m/W)

3-phase: 215 A​

direct buried

Current rating in conduit (30 °C)

3-phase: 185 A​

—

Short-circuit current (1 s, Cu, 250 °C, phase)

≈ 7.7 kA (7,700 A) per core

—

Short-circuit current (1 s, Cu, 250 °C, neutral)

≈ 3.9 kA (3,900 A) per core

—

Capacitance (core-to-sheath, approx.)

≈ 0.20 µF/km

XLPE

Inductive reactance (approx.)

≈ 0.08 Ω/km

at 50 Hz

Frequency

50/60 Hz AC

—


Reference values: 3×70+1×35 at 210 A three-phase, 400 V → max load ≈ 126 kW​ (cos φ = 0.8). Suitable for large-medium three-phase distribution with reduced neutral, industrial motors, and building sub-main feeders.


4. Thermal & Flame. 90 °C continuous, 250 °C short-time; ZC class C self-extinguishing — flame retardancy, not 950°C integrity; survives motor start-stop and feeder switching cycles; indoor preferred, UV-grade jacket optional.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

90 °C (continuous)

Max. short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Min. installation ambient temp.

0 °C (below 0 °C requires preheating)

Service ambient range

−20 °C to +90 °C

Flexing temp. range

0 °C to +90 °C

Fire Performance (ZC-YJV — Flame Retardant C)

Property

Value / Requirement

Flame retardant

GB/T 18380.12 / IEC 60332-1-2​ (single cable, self-extinguishing)

Flame retardant class

Class C​ (ZC) per GB/T 19666

Halogen content

Contains halogen (PVC sheath)

Smoke density

Not low-smoke (PVC)

Corrosivity

Corrosive (PVC)

Toxicity

Toxic fumes when burned (PVC)

EMI shielding

None (no metallic screen/armour)


5. Installation Practice & Handling. 70 mm² phase lugs, 35 mm² neutral lug, heavy glands to ≈23 mm OD, hydraulic crimp/torque per table; bend ≥ 15×OD ≈ 345 mm; apply duct/bundle derating; keep the 3+1 bundle round; verify three-phase continuity, phase sequence, neutral and insulation after pulling.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 15 × OD → ≈ 435 mm at Ø29.0 mm

four-core unarmoured

Max. pulling tension (phase)

1,050 N per core (70 mm² × 15 N/mm²)

Cu conductor limit

Max. pulling tension (neutral)

525 N per core (35 mm² × 15 N/mm²)

Cu conductor limit

Direct burial

Suitable (with sand bedding)

—

Surface mounting

Heavy-duty cable tray, ladder, cleats

—

Conduit ID

≥ 55 mm

—

Fixing

heavy-duty cleats, cable ties

—

Impact resistance

Moderate

—

Water resistance

Good (PVC sheath)

—

UV resistance

Fair (PVC degrades outdoors, use UV-resistant PVC or conduit)

—

Flex life

Good (Class 2 stranded)

fixed installation

Termination note

Standard compression lugs or mechanical connectors

—


6. Typical Service Applications. Medium three-phase motors and compressors, workshop sub-distribution feeders, MCC-to-equipment supplies, machine feeder circuits and balanced power branches.

0.6/1kV ZC-YJV 3x70+1x35mm²‌ Copper XLPE PVC Flame-Retardant Power Cable for Transformer Room LV Outgoing Circuits


7. Testing & QA Regime (16 items). Routine: phase DC resistance (70), neutral DC resistance (35), 3.5 kV withstand, insulation resistance, 3-phase+neutral continuity, phase/neutral insulation thickness, sheath thickness, dimensional check, strand construction, eccentricity, print legibility, mass, packing inspection. Type: ZC flame test, short-circuit rating, sheath mechanical.


Cable Parameters


ZR-YJV 3×70+1×35 mm² — Flame-Retardant 3+1-Core Power Cable (0.6/1 kV) · Expanded Parameter Datasheet
Copper conductor · XLPE insulation · PVC sheath · 3 phase cores @ 70 mm² + 1 neutral core @ 35 mm² · complies with GB/T 12706.1, IEC 60502-1, GB/T 3956, GB/T 19666 · figures marked (est.) are engineering estimates; verify against factory certificate
Code Parameter Value Unit Remarks
01 · Identification
Ref: GB/T 12706.1 / IEC 60502-1; flame class GB/T 19666; Um = 1.2 kV; 50 Hz
1-A Catalogue description Copper-conductor XLPE-insulated PVC-sheathed flame-retardant power cable, 3+1 core configuration — ZR-YJV series; PVC sheath contains halogen
1-B Model code ZR-YJV 3×70+1×35 — Three 70 mm² phase cores + one 35 mm² neutral core
1-C Governing specifications GB/T 12706.1; IEC 60502-1 — Conductor construction per GB/T 3956
1-D Nominal system voltage 0.6/1 kV Highest voltage for equipment Um = 1.2 kV; AC 50 Hz
1-E Conductor arrangement Three phase cores (L1/L2/L3) cabled around a central neutral core (N) — Standard three-phase four-wire (TN-C) arrangement
1-F Rated cross-sectional areas 3 × 70 (phase) + 1 × 35 (neutral) mm² Phase cores carry line current; neutral sized per GB/T 12706.1
1-G Flame-retardant category Class C (ZC) — standard for "ZR" marking — Upgradable to ZA/ZB on request
1-H Insulation system XLPE (cross-linked polyethylene) / PVC (polyvinyl chloride) sheath — 90 °C XLPE class; ST2 PVC jacket
02 · Conductor
Ref: GB/T 3956 / IEC 60228 Class 2 — phase 70 mm² = 19 wires; neutral 35 mm² = 7 wires
2-A Conductor material Annealed electrolytic copper (high conductivity) — Minimum 97% IACS conductivity
2-B Stranding class Class 2 (compact stranded) — GB/T 3956 / IEC 60228
2-C Phase stranding (×3) 19 × 2.14 mm (19/2.14) each — 1+6+12 concentric rings; nominal 70 mm²
2-D Neutral stranding (×1) 7 × 2.52 mm (7/2.52) — 1+6 concentric rings; nominal 35 mm²
2-E Phase conductor diameter ≈ 10.7 mm Per phase core (19 × 2.14)
2-F Neutral conductor diameter ≈ 7.56 mm Neutral core (7 × 2.52)
2-G Phase DC resistance @ 20 °C 0.268 Ω/km GB/T 3956 Class 2 Cu (70 mm²)
2-H Neutral DC resistance @ 20 °C 0.524 Ω/km GB/T 3956 Class 2 Cu (35 mm²)
2-I Phase conductor mass ≈ 622 kg/km per core 70 mm² × 8.89 g/cm³ (est.)
2-J Neutral conductor mass ≈ 311 kg/km 35 mm² × 8.89 g/cm³ (est.)
03 · Insulation
Ref: GB/T 12706.1 — phase 1.1 mm (70 mm²); neutral 0.9 mm (35 mm²)
3-A Dielectric material Cross-linked polyethylene (XLPE) — Chemically cross-linked during extrusion
3-B Phase insulation thickness 1.1 mm GB/T 12706.1 for 70 mm²
3-C Neutral insulation thickness 0.9 mm GB/T 12706.1 for 35 mm²
3-D Diameter over phase insulation ≈ 12.9 mm Per phase core (calculated)
3-E Diameter over neutral insulation ≈ 9.36 mm Neutral core (calculated)
3-F Insulation mass (total) ≈ 195 kg/km 3 phase + 1 neutral, density 0.92 g/cm³ (est.)
3-G XLPE tensile strength ≥ 12.5 MPa GB/T 12706.1 / GB/T 2951
3-H XLPE elongation at break ≥ 200 % GB/T 12706.1 / GB/T 2951
04 · Assembly
Ref: 3+1 cabling — neutral at centre, three phase cores around; round bundle
4-A Lay-up arrangement Central neutral core + three phase cores in triangular ring + non-hygroscopic filler + binder tape — Produces round, stable cable
4-B Filler material Polypropylene (PP) rope / non-hygroscopic filler — Keeps cable round; absorbs no water
4-C Binder tape Polyester tape, single wrap — Holds cores together during sheathing
4-D Lay ratio (approx.) 12 : 1 to 16 : 1 — Cabling pitch / assembly diameter
4-E Diameter over cabled assembly ≈ 35.2 mm Derived: Ø 39.6 − 2 × 2.2 sheath (est.)
05 · Sheath
Ref: GB/T 12706.1 ST2; dimensions engineering-estimated (not in Zhongce 3+1 table)
5-A Jacket material Flame-retardant PVC, ST2 compound — Black standard; other colours on request
5-B Nominal sheath thickness 2.2 mm Interpolated between 50 mm² (2.0) and 95 mm² (2.5) (est.)
5-C Overall finished diameter ≈ 39.6 mm Calculated from assembly + sheath (est.)
5-D Approximate cable mass ≈ 2800 kg/km Cu + XLPE + PVC + filler (est.)
5-E Sheath colour Black (standard) — Custom colours available
5-F PVC tensile strength ≥ 10.0 MPa GB/T 12706.1 / GB/T 2951
5-G PVC elongation at break ≥ 125 % GB/T 12706.1 / GB/T 2951
5-H PVC thermal stability ≥ 200 min 200 °C Congo-red test (GB/T 2951)
06 · Electrical
Ref: GB/T 12706.1; ampacity engineering-estimated (70 mm² three-core basis)
6-A Phase conductor DC resistance 0.268 Ω/km GB/T 3956 @ 20 °C, each phase
6-B Neutral conductor DC resistance 0.524 Ω/km GB/T 3956 @ 20 °C, neutral
6-C Routine voltage proof 3.5 kV AC / 5 min — No breakdown; 50 Hz sine wave
6-D Insulation resistance (finished) ≥ 36.7 MΩ·km @ 20 °C on completed cable
6-E XLPE volume resistivity ≥ 1 × 10¹² Ω·cm Material-level property
6-F Capacitance (typical) ≤ 0.40 μF/km Per phase core to earth/neutral (est.)
6-G Inductance (typical) ≈ 0.27 mH/km Three-core cable, 50 Hz (est.)
6-H AC impedance @ 50 Hz ≈ 0.27 Ω/km √(R² + X²); R-dominant (est.)
6-I Short-circuit current (1 s) ≈ 8.05 kA I = k·A/√t, k=115 for Cu/XLPE (est.)
6-J Buried ampacity @ 25 °C ≈ 255 A Engineering estimate; Cu, 3 phase loaded
6-K Air ampacity @ 30 °C ≈ 245 A Engineering estimate; Cu, 3 phase loaded
6-L Earth-fault loop impedance Per project calculation — Depends on length & upstream system
07 · Thermal
Ref: XLPE class per GB/T 12706.1 / IEC 60502-1
7-A Continuous conductor temperature 90 °C XLPE insulation class rating
7-B Short-circuit temperature (≤ 5 s) 250 °C GB/T 12706.1 / IEC 60502-1
7-C Ambient operating range -20 to +45 °C Per manufacturer datasheet family
7-D Minimum installation temperature 0 °C Pre-heat drums if colder than 0 °C
7-E Maximum soil temperature (direct burial) 25 °C Reference for buried ampacity
7-F Thermal resistance (insulation+sheath) ≈ 3.5 K·m/W Typical for XLPE/PVC 0.6/1 kV (est.)
08 · Fire (ZR)
Ref: GB/T 19666; GB/T 18380.12; GB/T 18380.35 (20 min, ≥ 1.5 L/m)
8-A Flame-retardant grade Class C (ZC) — default for "ZR" — PVC sheath is halogen-containing
8-B Single-cable vertical flame test Compliant — Method per GB/T 18380.12
8-C Bunched-cable flame test — C Char height ≤ 2.5 m — Method per GB/T 18380.35
8-D Halogen status Halogenated (not LSZH) — Use WDZ-YJY for low-smoke zero-halogen
8-E Smoke density (PVC) Higher than LSZH — PVC emits smoke under fire
8-F Oxygen index (FR-PVC) ≥ 28 % Typical flame-retardant PVC compound (est.)
09 · Installation
Ref: Q/GDW 13244.1-2018; GB 50168
9-A Minimum bending radius (multi-core) ≥ 15 × actual OD — ≈ 594 mm for Ø 39.6 mm
9-B Approved laying methods Conduit, tray, trench, duct, trunking, direct burial — Mechanical protection required for direct burial
9-C Post-install commissioning test DC 4U0 = 2.4 kV / 15 min — Per Q/GDW 13244.1-2018
9-D Maximum pulling tension ≤ 3000 N Rule of thumb: 40 N/mm² of conductor area (est.)
9-E Storage conditions Dry, covered, −20 to +45 °C — Avoid direct sunlight and moisture
9-F Cold-weather pre-heating Warm to ≥ 0 °C before pulling — Prevents jacket cracking
10 · Packing
Ref: custom lengths; marking per GB/T 6995 / project spec
10-A Standard supply length 100 m per coil or wooden drum — Custom lengths available on request
10-B Cable surface marking Type, voltage, manufacturer, year, metre marks — Per GB/T 6995 and project requirements
10-C Recommended drum size ≥ Ø 1200 mm flange — For 100 m of Ø 39.6 mm cable (est.)
10-D Approx. net weight per 100 m drum ≈ 280 kg 100 m × 2800 kg/km (est.)


Cable Test Parameters


ZR-YJV 3×70+1×35 mm² — Test & Verification Schedule (GB/T 12706.1 & IEC 60502-1)
Stage Test Item Method / Standard Acceptance Criterion Notes
Routine Phase conductor DC resistance GB/T 3956 (IEC 60228) ≤ 0.268 Ω/km @ 20 °C (70 mm²) Every production length
Routine Neutral conductor DC resistance GB/T 3956 (IEC 60228) ≤ 0.524 Ω/km @ 20 °C (35 mm²) Every production length
Routine Power-frequency withstand GB/T 12706.1 / IEC 60502-1 3.5 kV AC / 5 min, no breakdown Conductor to earth/water bath
Routine Dimensional inspection GB/T 2951 Phase ins. ≥ 1.1 mm; neutral ins. ≥ 0.9 mm; sheath ≥ 2.2 mm; OD within tolerance Wall & diameter check
Routine Conductor continuity Visual / electrical All cores continuous, no break Every length
Sample XLPE hot-set test GB/T 12706.1 §16.3.13 / GB/T 2951.11 200 ± 3 °C, 15 min, 0.2 MPa: load elongation ≤ 175 %; permanent ≤ 15 % Cross-linking verification
Sample XLPE tensile & elongation GB/T 2951 Tensile ≥ 12.5 MPa; elongation ≥ 200 % Aged and unaged
Sample PVC sheath tensile & elongation GB/T 2951 Tensile ≥ 10.0 MPa; elongation ≥ 125 % Aged and unaged
Sample PVC thermal stability GB/T 2951 (Congo-red) ≥ 200 min @ 200 °C HCI evolution test
Sample Conductor geometry GB/T 3956 Phase: 19 × 2.14 mm Ø ≈ 10.7; neutral: 7 × 2.52 mm Ø ≈ 7.56 Per batch
Type Single-cable flame test GB/T 18380.12 No flame to upper reference mark ZR property
Type Bunched flame test — C GB/T 18380.35 Char ≤ 2.5 m; 20 min; ≥ 1.5 L/m Class C compliance
Type Bending test GB/T 12706.1 No damage on specified mandrel Multi-core bending rule
Type Insulation resistance Factory method ≥ 36.7 MΩ·km @ 20 °C Not routine under GB/T 12706.1
Post-install DC withstand commissioning Q/GDW 13244.1-2018 2.4 kV DC / 15 min, no breakdown Required for new installations
Post-install Phase identification Visual / continuity L1/L2/L3/N correctly labelled at both ends Before energisation


Cable Cross Section Structure


0.6/1kV ZC-YJV 3x70+1x35mm²‌ Copper XLPE PVC Flame-Retardant Power Cable for Transformer Room LV Outgoing Circuits

ZR-YJV 3×70+1×35 mm² — Cross-Section Construction Diagram (Schematic)
Layered 3+1 conductor build-up from copper strand to PVC jacket · nominal dimensions per GB/T 12706.1 / IEC 60502-1 · dimensions marked (est.) are engineering estimates — confirm with factory certificate
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Phase conductor (Cu) × 3 Annealed copper, Class 2 compact strand — 19 wires of 2.14 mm per core (19/2.14, 1+6+12 layout), nominal area 70 mm² each — ≈ 10.7 (Ø each phase core) Line-current carrying phase conductors; DC resistance capped at 0.268 Ω/km at 20 °C
2 Neutral conductor (Cu) × 1 Annealed copper, Class 2 compact strand — 7 wires of 2.52 mm (7/2.52, 1+6 layout), nominal area 35 mm² — ≈ 7.56 (Ø neutral core) Return / neutral path; DC resistance capped at 0.524 Ω/km at 20 °C
3 Phase insulation (XLPE) × 3 Cross-linked polyethylene dielectric 1.1 ≈ 12.9 (Ø each phase core, incl. insulation) Electrical isolation; 90 °C continuous rating; withstands 3.5 kV for 5 min
4 Neutral insulation (XLPE) × 1 Cross-linked polyethylene dielectric 0.9 ≈ 9.36 (Ø neutral core, incl. insulation) Electrical isolation for the neutral conductor
5 Core assembly Neutral core at centre + three phase cores cabled around + PP filler + polyester binder tape — ≈ 35.2 (Ø over assembled cores, est.) 3+1 configuration; forms a round, stable bundle
6 Outer jacket (PVC) Flame-retardant PVC, ST2 compound, black 2.2 ≈ 39.6 (Ø finished cable, est.) Mechanical and moisture protection; ZC flame retardance per GB/T 19666
Key Dimensions & Properties (expanded)
Finished cable diameter ≈ 39.6 mm Engineering estimate (not in Zhongce table)

Approximate cable mass ≈ 2800 kg/km Cu + XLPE + PVC + filler (est.)

Nominal voltage rating 0.6/1 kV AC 50 Hz; maximum system voltage Um = 1.2 kV

Conductor temperature limits 90 / 250 °C Continuous service / short-circuit (≤ 5 s)

Minimum bend radius (multi-core) ≥ 15 × OD ≈ 594 mm OD = actual finished cable diameter

Flame-retardant classification ZC (ZR) — Per GB/T 19666

Short-circuit current (1 s) ≈ 8.05 kA I = k·A/√t, k=115 for Cu/XLPE (est.)

AC impedance @ 50 Hz ≈ 0.27 Ω/km √(R² + X²); R-dominant (est.)

Capacitance (typical) ≤ 0.40 μF/km Per phase core (est.)

Inductance (typical) ≈ 0.27 mH/km Three-core cable (est.)

Air ampacity @ 30 °C ≈ 245 A Engineering estimate; Cu, 3 phase loaded

Buried ampacity @ 25 °C ≈ 255 A Engineering estimate; Cu, 3 phase loaded

Schematic — not to exact scale. Values marked (est.) are engineering estimates interpolated between 3×50+1×25 and 3×95+1×50; confirm against factory test certificate.


Cable Construction Description


Construction Description — ZR-YJV 3×70+1×35 mm² 
Layer-by-layer build-up narrative, conductor through outer jacket · per GB/T 12706.1 & IEC 60502-1 · CU / XLPE / PVC · 0.6/1 kV class · dimensions marked (est.) are engineering estimates
1. Product Identity & Ratings
ZR-YJV 3×70+1×35 belongs to the flame-retardant 3+1-core family: it combines three 70 mm² copper phase conductors with a single 35 mm² copper neutral conductor, all insulated in XLPE and enclosed in one ST2 PVC jacket, for 0.6/1 kV service. Manufacturing and type testing follow GB/T 12706.1 / IEC 60502-1, conductor stranding follows GB/T 3956, and the ZR marking corresponds to class ZC under GB/T 19666. The finished cable measures roughly 39.6 mm across (engineering estimate) and weighs about 2800 kg per kilometre; supply is in 100 m coils or wooden drums.
This 3+1 build is the conventional three-phase four-wire format: the reduced neutral core sits in the middle while the three phase cores are laid up around it. With all three phase cores energised, the cable supports roughly 245 A in free air at 30 °C and roughly 255 A when directly buried at 25 °C (engineering estimates based on 70 mm² three-core references) — suited to heavy distribution feeders, transformer secondaries and large industrial mains.
2. Copper Stranded Conductors
Each 70 mm² phase core is formed from nineteen 2.14 mm annealed wires in the 1+6+12 compact arrangement (19/2.14) — the Class 2 standard for this cross-section — yielding an outside diameter of about 10.7 mm and a DC resistance ceiling of 0.268 Ω/km at 20 °C. The 35 mm² neutral core uses seven 2.52 mm wires (7/2.52) to about 7.56 mm Ø, with resistance capped at 0.524 Ω/km. Both are compact Class 2 strands that deliver clean circular profiles and dependable crimp terminations; the 19-wire phase construction provides greater flexibility than the 7-wire smaller sections.
3. XLPE Dielectric Insulation
XLPE is extruded at 1.1 mm onto the phase cores (the wall GB/T 12706.1 assigns to 70 mm² conductors) and at 0.9 mm onto the 35 mm² neutral core — producing approximately 12.9 mm per phase core and 9.36 mm for the neutral core over the insulation. The dielectric is rated for 90 °C continuous duty and 250 °C for five seconds, maintains volume resistivity above 1×10¹² Ω·cm, passes the routine 3.5 kV AC five-minute voltage proof, and offers tensile strength ≥ 12.5 MPa with elongation ≥ 200 %.
4. Cabling & PVC Outer Jacket
After insulation, the neutral core is placed at the centre and the three phase cores are cabled around it in a triangular ring with polypropylene filler and a polyester binder tape, forming a bundle of about 35.2 mm diameter. A 2.2 mm layer of flame-retarded ST2 PVC is then extruded over the assembly to the estimated 39.6 mm finish. The jacket provides ZC behaviour through GB/T 18380.12 and GB/T 18380.35, offers tensile strength ≥ 10 MPa and elongation ≥ 125 %; because PVC is halogenated, low-smoke zero-halogen projects should specify WDZ-YJY instead.
5. Site Handling & Operational Notes
• Observe the 15 × OD minimum bending radius (≈ 594 mm).  • Perform the DC 4U0 = 2.4 kV / 15 min commissioning test before first energisation.  • Service ambient spans −20 to +45 °C; warm drums below 0 °C before pulling.  • Derate the 245 A (air) / 255 A (buried) references for ambient temperature, grouping and soil conditions.  • Maximum pulling tension ≤ 3000 N; use appropriate pulling grips and lubricant.  • Select lugs and glands matched to the 10.7 mm phase core, 7.56 mm neutral core and 39.6 mm jacket diameter.  • Short-circuit rating ≈ 8.05 kA for 1 second — verify against protective device settings.


8. Factory Advantages.

  • Balanced 3+1 sizing — 3×70 phases with a 1×35 neutral avoids excess copper on balanced medium loads.
  • Stable XLPE cure — even cross-linking keeps the 90°C dielectric consistent under sustained feeder duty.
  • Dosed ZC compound — self-extinguishing jacket protects switchrooms and workshop wiring spaces.
  • Length-on-demand — cut to exact feeder meter with sealed ends.
  • Dual-section resistance log — both 70 phase and 35 neutral R recorded to lot.
  • Continuous print line — type, phase/neutral section, ZC, voltage and length along jacket.
  • Phase-color option — L1/L2/L3/N colors reduce wiring errors at MCC blocks.
  • Rated drum pack — medium-heavy section wound on a rated wooden drum, ends sealed.
  • Certified QA pack — routine + type test record shipped per batch.

0.6/1kV ZC-YJV 3x70+1x35mm²‌ Copper XLPE PVC Flame-Retardant Power Cable for Transformer Room LV Outgoing Circuits


9. Packaging, Storage & Logistics. Cut to measured feeder length on a wooden drum with sealed ends; continuous marking; store dry indoor on drum supports, shaded, avoid direct UV.

0.6/1kV ZC-YJV 3x70+1x35mm²‌ Copper XLPE PVC Flame-Retardant Power Cable for Transformer Room LV Outgoing Circuits


10. Procurement Specification. State "ZC-YJV 3×70+1×35", length, class C, phase colors; note the reduced 35 neutral for balanced loads (enlarge on high VFD harmonics) and not fire-rated; request dual-section resistance log and 16-item QA record. Est. values confirmed against the factory certificate.


11. Cable Industry FAQ.

  • Q1: How does 3×70+1×35 differ from 3×25+1×16? One major size up: phases 70 vs 25, neutral 35 vs 16; OD 23 vs 12 mm, mass 2900 vs 760 kg/km, phase current 175 vs 78 A, resistance 0.268 vs 0.741 Ω/km (phase); aimed at medium motors and feeders rather than small branches.
  • Q2: Why a reduced 35 neutral? Balanced three-phase medium loads draw little neutral current; a 35 neutral controls cost; enlarge it where VFD/rectifier harmonics are high.
  • Q3: Is ZC fire-resistant? No. Class C self-extinguishes; it does not hold live at 950°C/180min.
  • Q4: Resistance values? Phase 70 ≤0.268; neutral 35 ≤0.524 Ω/km at 20°C.
  • Q5: Screen or armor? Unscreened standard; add braid near VFD EMI; steel-tape armor for ground-crushing ducts.
  • Q6: Phase current? ≈175 A (est.) free air 30°C; derate in crowded ducts and trays.
  • Q7: Bending? ≥345 mm (15×OD); use bending tools on this heavier section.
  • Q8: Connectors? 70 mm² lugs on phases, 35 mm² lug on N; gland to ≈23 mm OD.
  • Q9: Indoor or outdoor? Indoor preferred; specify UV-stabilized jacket for exposed runs.
  • Q10: Packing? Rated wooden drum with sealed ends.
  • Q11: What proof ships? Dual-section resistance log + 16-test record; est. values confirmed against certificate.