ZR-YJV 1*240mm² Fire Retardant Single Conductor Cable, 0.6/1kV Pure Copper, XLPE PVC Sheath for Indoor Power Wiring

ZR-YJV 1*240mm² Fire Retardant Single Conductor Cable, 0.6/1kV Pure Copper, XLPE PVC Sheath for Indoor Power Wiring

Basic Properties

country of origin
China
brand name
TD
certificate
CE/ISO/CCC
product model
ZR-YJV 1*240mm²

Trading Properties

moq
1 Meter
payment method
L/C,T/T
supply capacity
10000 meters per month

Product Summary

ZR-YJV 1*240mm² Fire Retardant Single Conductor Cable, 0.6/1kV Pure Copper, XLPE PVC Sheath for Indoor Power Wiring Code Mean:ZR-Flame Retardant,YJ-XLPE Insulation,V-PVC Outer Sheathed ZR-YJV 1×240 mm² — Product Briefing 1. What It Is. The ZR-YJV 1×240 is the heavy feeder class of the flame...

Product Details

Conductor:
Bare Annealed Copper, Class 2 Stranded Circular, 37×∅2.87 Mm​ (typical), Conductor Ø ≈ 20.1 Mm
Conductor nominal area:
240 Mm²
Conductor construction:
Class 2, 37×∅2.87 Mm​ Min. 37 Wires Per GB/T 3956 (>95 Mm²)
Conductor diameter (approx.):
20.1mm
Insulation:
XLPE Compound, Extruded
Insulation thickness (nominal)​:
1.2 Mm​ (GB/T 12706.1, 150–240 Mm² Class)
Diameter over insulation (approx.):
22.5 Mm (20.1 + 2×1.2)
Filler / binder:
Flame-retardant (FR) Non-hygroscopic Tape / PP Mesh
Outer sheath:
Flame-retardant PVC Compound (ZR Grade)​ — Contains Halogen, Not Low-smoke
Sheath thickness (nominal):
1.4mm
Overall cable diameter:
28.5 – 29.5 Mm
Approx. weight:
1,920 – 2,050 Kg/km
Long-term service temperature:
90 °C
Short-circuit temperature (≤5 s):
250°C
Emergency overload:
105–130 °C (limited Duration)
Routine test:
3.5 KV AC / 5 Min; Type Test 4.0 KV
Volume resistivity @90 °C:
≥ 10¹² Ω·cm

Product Description

ZR-YJV 1*240mm² Fire Retardant Single Conductor Cable, 0.6/1kV Pure Copper, XLPE PVC Sheath for Indoor Power Wiring


Code Mean:ZR-Flame Retardant,YJ-XLPE Insulation,V-PVC Outer Sheathed

ZR-YJV 1×240 mm² — Product Briefing

1. What It Is. The ZR-YJV 1×240 is the heavy feeder class of the flame-retardant CU/XLPE/PVC family — a single core rated 0.6/1 kV (Um = 1.2 kV), 50 Hz, built to GB/T 12706.1 / IEC 60502-1, conductor per GB/T 3956 / IEC 60228, fire performance per GB/T 19666 / GB/T 18380 (default ZC).

2. Construction, Core to Jacket. Layer stack with nominal figures:


Layer Build Wall Diameter
Core Annealed copper, Class 2, 61 × 2.25 mm (61/2.25, 1+6+12+18+24), 240 mm² — ≈ 17.5 mm (compacted; up to ≈ 19.5 mm round-lay)
Dielectric Cross-linked polyethylene 1.7 mm ≈ 20.9 mm over insulation
Jacket Flame-retarded PVC, ST2, black 2.0 mm ≈ 24.9 mm overall

Weight ≈ 2410 kg/km (2400–2500 across makers; copper alone ≈ 2134 kg/km); OD 24.9–26.4 mm.


ZR-YJV 1*240mm² Fire Retardant Single Conductor Cable, 0.6/1kV Pure Copper, XLPE PVC Sheath for Indoor Power Wiring


3. Electrical Performance. DC resistance ≤ 0.0754 Ω/km @ 20 °C; routine withstand 3.5 kV AC / 5 min; XLPE volume resistivity ≥ 1×10¹² Ω·cm; typical insulation resistance ≥ 36.7 MΩ·km; capacitance ≤ 0.45 μF/km. Reference ampacity ≈ 625 A in air (30 °C) and ≈ 555 A direct-buried — derate per GB/T 16895 / IEC 60364.


Parameter

Value

Note

Rated voltage U₀/U

0.6 / 1 kV

Uₘ = 1.2 kV

Test voltage AC (5 min)

3.5 kV​

Routine

Type-test voltage

4.0 kV

IEC 60502

DC resistance @20 °C (Class 2 Cu)​

≤ 0.0754 Ω/km​

GB/T 3956 / IEC 60228 max

AC resistance @90 °C (est.)

≈ 0.098 Ω/km

copper temp. coefficient

Current rating in air (30–40 °C, single circuit, single-core)

≈ 590 – 610 A​

PVC sheath; design ≈ 590 A​

Direct buried (20 °C, soil 1.0 K·m/W, 0.7 m)

≈ 535 – 550 A​

design ≈ 535 A​

Short-circuit current (1 s adiabatic, Cu, 250 °C)

≈ 27.75 kA

reference

Frequency

50/60 Hz AC (DC usable)

—


4. Thermal & Mechanical Envelope. Continuous 90 °C; short-circuit 250 °C (≤ 5 s); ambient −20 to +45 °C; laying ≥ 0 °C; minimum bend radius 20 × OD (single core).


ZR-YJV 1×240 mm² Flame-Retardant Copper-Conductor XLPE-Insulated PVC-Sheathed Power Cable — Product Parameters (0.6/1 kV)
Construction: CU / XLPE / PVC  •  Standards: GB/T 12706.1, IEC 60502-1 (cable), GB/T 3956 (conductor), GB/T 19666 & GB/T 18380 (flame retardance)  •  Nominal values for reference — confirm against factory test certificate
No. Category Parameter Value Unit Notes / Standard Reference
A. Product Identification
1 Identification Product name Flame-retardant copper-conductor XLPE-insulated PVC-sheathed power cable — Designation ZR-YJV; "ZR" = flame-retardant (halogen-containing)
2 Identification Model designation ZR-YJV 1×240 — Cu / XLPE / PVC
3 Identification Design standards GB/T 12706.1; IEC 60502-1 — Conductor: GB/T 3956 / IEC 60228; flame retardance: GB/T 19666, GB/T 18380; safety: CCC / production licence
4 Identification Rated voltage U0/U 0.6/1 kV Max system voltage Um = 1.2 kV
5 Identification Rated frequency 50 Hz AC power distribution
6 Identification Number of cores 1 — Single-core cable
7 Identification Nominal cross-sectional area 240 mm² Nominal conductor cross-section per GB/T 3956
B. Cable Construction (from conductor to outer sheath)
8 Conductor Material Plain annealed copper (Cu) — High-conductivity electrolytic / oxygen-free copper
9 Conductor Conductor class Class 1 or Class 2 (typical: Class 2, stranded) — GB/T 3956 / IEC 60228
10 Conductor Typical stranding construction 61 wires × 2.25 mm (61/2.25, lay-up 1+6+12+18+24) — Class 2 round stranded; nominal section ≈ 240 mm²
11 Conductor Conductor diameter ≈ 17.5 mm ≈ 17.5 mm compact (17.5–19.5 mm across stranding practice)
12 Conductor Max. DC resistance of conductor at 20 °C 0.0754 Ω/km GB/T 3956, Class 2 copper; acceptance criterion for 240 mm²
13 Insulation Material Cross-linked polyethylene (XLPE) — Thermally cross-linked; natural/transparent colour
14 Insulation Nominal insulation thickness 1.7 mm GB/T 12706.1 / IEC 60502-1 (0.6/1 kV, 240 mm²)
15 Insulation Diameter over insulation ≈ 20.9 mm ≈ 17.5 + 2 × 1.7 (calculated, compact conductor)
16 Sheath Material Flame-retardant polyvinyl chloride (PVC, ST2 type) — Colour: black (or as ordered)
17 Sheath Nominal sheath thickness 2.0 mm GB/T 12706.1 / IEC 60502-1 (cabhr table)
18 Dimensions Approx. overall diameter 24.9 mm ≈ 24.9 mm (24.9–26.4 mm across sources: cabhr 24.9; ahtk 26.0; Meihe 26.4)
19 Dimensions Approx. cable weight ≈ 2410 kg/km cabhr 2410; Meihe 2400; ahtk 2500 (copper core alone ≈ 2134 kg/km)
C. Electrical Performance
20 Electrical Max. DC conductor resistance at 20 °C 0.0754 Ω/km GB/T 3956; routine measurement
21 Electrical Power-frequency withstand voltage (routine test) 3.5 kV / 5 min, no breakdown — AC 50 Hz; per GB/T 12706.1 / IEC 60502-1
22 Electrical Insulation resistance (finished cable, 20 °C) ≥ 36.7 MΩ·km Typical finished-cable reference for 0.6/1 kV XLPE cables; varies with geometry and manufacturer test method
23 Electrical XLPE volume resistivity at 20 °C ≥ 1 × 10¹² Ω·cm Material-level requirement (manufacturer reference)
24 Electrical Capacitance (single-core, approx.) ≤ 0.45 μF/km Manufacturer reference value
25 Electrical Reference ampacity — in air, 30 °C, single core ≈ 625 A cabhr table (625 A); depends on laying, grouping, ambient — apply correction factors per GB/T 16895 / IEC 60364
26 Electrical Reference ampacity — direct burial, 25 °C ≈ 555 A cabhr table; depends on soil thermal resistivity and depth
D. Thermal Performance
27 Thermal Max. continuous conductor temperature 90 °C XLPE insulation temperature class
28 Thermal Max. conductor temperature under short-circuit (≤ 5 s) 250 °C Per GB/T 12706.1 / IEC 60502-1
29 Thermal Ambient service temperature range -20 to +45 °C Per Qifan datasheet family; check project specification
30 Thermal Min. installation (laying) temperature 0 °C Pre-heat the cable if ambient is below 0 °C
E. Flame Retardance (ZR)
31 Flame retardance Flame-retardant class ZC (class C) by default for "ZR" — GB/T 19666; ZA / ZB available on request; halogen-containing PVC (not LSZH)
32 Flame retardance Single-cable vertical flame-spread test Pass — GB/T 18380.12
33 Flame retardance Bunched flame-spread test (class C) Char extent ≤ 2.5 m above burner bottom edge — GB/T 18380.35: non-metallic volume ≥ 1.5 L/m; flame application 20 min
34 Flame retardance Halogen content Halogen-containing (PVC) — For low-smoke, zero-halogen requirement select WDZ-YJY (LSZH) type
F. Installation
35 Installation Min. bending radius — single-core cable 20 × OD — Qifan & Huaneng datasheets; OD = actual cable diameter
36 Installation Laying methods Conduit, tray, cable trench, tunnel, duct, supported/suspended aerial — Also direct burial with mechanical protection where permitted
37 Installation Site withstand test after installation DC 4U0 = 2.4 kV, 15 min (recommended) — Per utility procurement standard Q/GDW 13244.1-2018; practice may vary by project
G. Packing & Delivery
38 Packing Standard delivery length 100 m per coil/drum (or as ordered) — Typical industry practice; custom lengths available
39 Packing Cable marking Model, rated voltage, manufacturer, year of manufacture, sequential length marks — Per GB/T 6995 / project specification
40 Packing Packing form Wooden drum / coil / export packing — As per customer requirement


5. Fire-Retardancy Credentials. Passes GB/T 18380.12 single burn and class-C bunched burn GB/T 18380.35 (char ≤ 2.5 m) → ZC per GB/T 19666. PVC contains halogen — spec WDZ-YJY for LSZH duty.


6. Verification & Testing. Routine: DC resistance, 3.5 kV/5 min, dimension audit (ins. ≥ 1.7 mm, sheath ≥ 2.0 mm). Sample: XLPE hot-set (200 ± 3 °C / 15 min / 0.2 MPa). Type: flame + bending. Site: DC 4U0 = 2.4 kV / 15 min (Q/GDW 13244.1-2018 practice).


ZR-YJV 1×240 mm² — Test / Verification Parameters (per GB/T 12706.1 & IEC 60502-1)
Test Stage Test Item Method / Standard Requirement / Acceptance Criterion Notes
Routine test Conductor DC resistance measurement GB/T 3956 (IEC 60228) ≤ 0.0754 Ω/km at 20 °C Measured on every production length
Routine test Power-frequency withstand voltage GB/T 12706.1 / IEC 60502-1 3.5 kV AC, 5 min, no breakdown Applied between conductor and water/earth; 50 Hz
Routine test Construction check — insulation & sheath thickness, outer diameter GB/T 2951 Within GB/T 12706.1 tolerances Insulation ≥ 1.7 mm nominal; sheath ≥ 2.0 mm nominal
Sample test Hot set (thermal elongation) test — XLPE insulation GB/T 12706.1 §16.3.13 / GB/T 2951.11 200 ± 3 °C, 15 min, stress 0.2 MPa: elongation under load ≤ 175 %; permanent elongation after cooling ≤ 15 % Verifies degree of cross-linking
Sample test Conductor construction & diameter check GB/T 3956 Class 2; 61 × 2.25 mm; Ø ≈ 17.5 mm Sampled per batch
Type test Single-cable vertical flame-spread test (flame retardance) GB/T 18380.12 No flame spread; charring does not reach top reference point ZR / ZC flame-retardant property
Type test Bunched flame-spread test, class C GB/T 18380.35 Char extent ≤ 2.5 m above burner bottom edge; flame application 20 min; non-metallic volume ≥ 1.5 L/m Class ZC per GB/T 19666
Type test Bending test (mechanical) GB/T 12706.1 Bend around specified mandrel without insulation/sheath damage Mandrel diameter related to cable OD
Post-installation DC withstand test after installation Q/GDW 13244.1-2018 (recommended practice) 4U0 = 2.4 kV DC, 15 min, no breakdown For new installations; verify project specification
Optional Insulation resistance measurement at 20 °C Manufacturer test method ≥ 36.7 MΩ·km (typical finished-cable value) Not a routine item in GB/T 12706.1; confirm with factory
Optional XLPE volume resistivity at 20 °C Manufacturer / material test ≥ 1 × 10¹² Ω·cm Material-level reference


7.Cross Section Structure


ZR-YJV 1*240mm² Fire Retardant Single Conductor Cable, 0.6/1kV Pure Copper, XLPE PVC Sheath for Indoor Power Wiring


ZR-YJV 1×240 mm² — Cable Cross-Section Structure (Schematic)
Layers from conductor to outer sheath · nominal values per GB/T 12706.1 / IEC 60502-1 · not to exact scale






No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductor (Cu) Annealed copper, Class 2 stranded — 61 × 2.25 mm (61/2.25, 1+6+12+18+24), nominal 240 mm² — ≈ 17.5 (Ø) Current-carrying element; max DC resistance ≤ 0.0754 Ω/km @ 20 °C
2 Insulation (XLPE) Cross-linked polyethylene 1.7 ≈ 20.9 (Ø over insulation) Dielectric barrier; rated 90 °C continuous; withstands 3.5 kV / 5 min
3 Outer sheath (PVC) Flame-retardant PVC, ST2 type, black 2 ≈ 24.9 (Ø overall) Mechanical & moisture protection; flame retardance ZC (ZR) per GB/T 19666
Key Dimensions & Properties
Overall diameter 24.9 mm 24.9–26.4 mm across sources (cabhr 24.9; ahtk 26.0; Meihe 26.4)

Approx. cable weight ≈ 2410 kg/km cabhr 2410; Meihe 2400; ahtk 2500; Cu core alone ≈ 2134 kg/km

Rated voltage 0.6/1 kV AC 50 Hz; max system voltage Um = 1.2 kV

Max conductor temperature 90 / 250 °C Continuous / short-circuit (≤ 5 s)

Min. bending radius (single-core) 20 × OD — OD = actual cable diameter

Flame-retardant class ZC (ZR) — GB/T 19666


Product Structure Introduction — ZR-YJV 1×240 mm² (English)
Layered construction description, from conductor to outer sheath · per GB/T 12706.1 & IEC 60502-1 · CU / XLPE / PVC · 0.6/1 kV

1. What This Cable Is
ZR-YJV 1×240 is the large-format member of the flame-retardant YJV family: one copper core, XLPE insulation and a PVC sheath, rated 0.6/1 kV AC. It is built and verified to GB/T 12706.1 / IEC 60502-1, with the conductor per GB/T 3956 / IEC 60228 and the “ZR” fire-retardant mark per GB/T 19666 (default ZC). Typical package: about 24.9 mm outside diameter, ≈ 2410 kg/km mass, 100 m drums.
This size suits heavy feeders where a 240 mm² copper path is required; it is a fixed-installation product and must not be flexed continuously.

2. Conductor Build (Inner Layer)
Sixty-one annealed copper wires of 2.25 mm (61/2.25, concentric lay-up 1+6+12+18+24) are stranded into a Class 2 conductor of 240 mm² nominal section. The multi-wire architecture gives the bundle enough compliance to be pulled around trays and through ducts, and the 20 °C DC resistance is kept within 0.0754 Ω/km. Compaction yields a core of about 17.5 mm; a round-lay (non-compacted) build may reach up to ≈ 19.5 mm.

3. Dielectric Build (Middle Layer)
The core receives a 1.7 mm extrusion of cross-linked polyethylene, growing the diameter over insulation to ≈ 20.9 mm. Cross-linking upgrades the polymer into a thermoset, permitting 90 °C continuous operation and 250 °C for five seconds in fault conditions. Electrically, the layer guarantees volume resistivity ≥ 1×10¹² Ω·cm and every drum passes 3.5 kV AC for 5 minutes as a routine test.

4. Sheath Build (Outer Layer)
A 2.0 mm black PVC sheath (flame-retardant ST2 compound) closes the cable at ≈ 24.9 mm. Beyond shielding the dielectric from moisture, abrasion and impact, the jacket is what carries the ZC fire rating — proven through GB/T 18380.12 (single burn) and GB/T 18380.35 (class-C bunched, char limit 2.5 m). PVC means halogen: choose WDZ-YJY wherever zero-halogen, low-smoke behaviour is compulsory.

5. User Guidance & Constraints
• Single-core bending limit 20 × OD.  • Commission only after the DC 4U0 = 2.4 kV / 15 min site test.  • Service ambient −20 to +45 °C; warm drums below 0 °C.  • Apply derating for bundling and burial before final sizing.  • Confirm core diameter from the factory certificate before ordering lugs, glands and joints.


8. Precautions in Use. Keep bends ≥ 20 × OD; unreel without twisting; shield from UV and sharp edges; run the site DC test before energising; pick lugs/glands on the actual core diameter; do not flex continuously.


ZR-YJV 1*240mm² Fire Retardant Single Conductor Cable, 0.6/1kV Pure Copper, XLPE PVC Sheath for Indoor Power Wiring


9. Application Scope. Main switchboard tails, transformer LV connections, large motor feeders, risers and industrial sub-mains — trays, conduits, trenches, tunnels, ducts; indoor or sheltered outdoor.


ZR-YJV 1*240mm² Fire Retardant Single Conductor Cable, 0.6/1kV Pure Copper, XLPE PVC Sheath for Indoor Power Wiring


10. How to Order. ZR-YJV 0.6/1 kV 1×240, length, drum type, marking. Standard 100 m drums. Confirm with the factory certificate before installation.