1x120mm2 Single Core Cable Full Gauge Pure Copper Anti Aging Flame Retardant Power

1x120mm2 Single Core Cable Full Gauge Pure Copper Anti Aging Flame Retardant Power

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
ZR-YJV 1*120mm²

Trading Properties

moq
1 Meter
payment method
L/C,T/T
supply capacity
10000 meters per month

Product Summary

ZR-YJV 1*120mm² Single Core Cable Full Gauge Pure Copper Anti Aging Flame Retardant Powe Cable Designation & Meaning Code Meaning ZC Flame retardant C— IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 1×120 mm² Single core, 120 mm² copper conductor Construction: ...

Product Details

Highlight:

Single Core Cable

,

Single Core Cable Pure Copper

,

Anti Aging Flame Retardant Power Cable

Conductor:
Bare Annealed Copper, Class 2 Stranded Circular, 37×∅2.03 Mm​ (typical), Conductor Ø ≈ 14.2 Mm
Conductor nominal area:
120 Mm²
Conductor construction:
Class 2, 37×∅2.03 Mm​ Min. 37 Wires Per GB/T 3956 (>95 Mm²)
Conductor diameter (approx.):
14.2 Mm
Insulation:
XLPE Compound, Extruded
Insulation thickness:
1.1 Mm​ (GB/T 12706.1, 70–120 Mm² Class)
Diameter over insulation (approx.):
16.4 Mm(14.2 + 2×1.1)
Sheath nominal thickness:
1.4 Mm​(single-core PVC)
Overall cable diameter:
21.5 – 22.5 Mm
Approx. weight:
1,100 – 1,180 Kg/km
Long-term service temperature:
90 °C
Short-circuit temperature (≤5 s):
250 °C
Emergency overload:
105–130 °C (limited Duration)
Routine test:
3.5 KV AC / 5 Min; Type Test 4.0 KV
Volume resistivity @90 °C:
≥ 10¹² Ω·cm

Product Description

ZR-YJV 1*120mm² Single Core Cable Full Gauge Pure Copper Anti Aging Flame Retardant Powe

Cable Designation & Meaning

Code

Meaning

ZC

Flame retardant C— IEC 60332-3-24, Category C

YJ

Cross-linked polyethylene (XLPE) insulation

V

PVC sheath

1×120 mm²

Single core, 120 mm² copper conductor


Construction: Single Class 2 stranded copper conductor, XLPE insulation, PVC outer sheath (no armour, no shield).

1x120mm2 Single Core Cable Full Gauge Pure Copper Anti Aging Flame Retardant Power


ZC-YJV 1×120 mm² — LV Single-Core Power Cable — Specification & Engineering Data

1. Overview & Ratings. ZC-YJV 1×120 is a single-core LV power cable rated 0.6/1 kV (Um = 1.2 kV), 90 °C continuous, ZC C-class flame retardant. A single 120 mm² compacted stranded copper conductor (Class 2) enclosed in cream-buff XLPE insulation and dark bronze brown PVC outer sheath. Finished OD ≈ 17.8 mm, ≈ 1180 kg/km, 500 m wooden drums.


2. Construction Stack (Conductor → Outer).

Layer Build Wall Diameter
Conductor Compacted stranded Cu, Class 2, 120 mm² — ≈ 13.6 mm
XLPE insulation Cross-linked polyethylene, cream-buff ≈ 1.5 mm ≈ 16.6 mm
PVC outer sheath PVC, ZC flame retardant, dark bronze ≈ 1.9 mm ≈ 17.8 mm (finished)


3. Electrical Characteristics. DC resistance ≤ 0.253 Ω/km at 20 °C (compact Cu 120 mm²); test voltage 3.5 kV AC / 5 min; insulation resistance ≥ 36.7 MΩ·km. Nominal ampacity ≈ 270 A (air, 30 °C). Short-circuit rating ≈ 10.6 kA / 1 s.

Insulation & Sheath Data

Property

Value

Insulation material

XLPE (cross-linked polyethylene), Type TR-XLPE

Outer sheath material

PVC (polyvinyl chloride), Type ST₂

Long-term service temp.

90 °C (continuous, XLPE insulation)

Short-circuit temp. (≤5 s)

250 °C (Cu conductor limit for XLPE)

Emergency overload temp.

130 °C (short term, ≤1 h)

Test voltage AC (5 min)

3.5 kV (routine test, 0.6/1 kV class)

Dielectric strength

≥ 20 kV/mm (room temp.)

Volume resistivity @20 °C

≥ 1×10¹⁴ Ω·cm

Shield

None​ (unshielded design)

Electrical Parameters

Parameter

Value

Note

Rated voltage U₀/U

0.6 / 1 kV

GB/T 12706.1 / IEC 60502-1

Max. system voltage

1.2 kV AC

—

Test voltage AC (5 min)

3.5 kV

Routine test (conductor-to-sheath)

DC resistance @20 °C

≤ 0.153 Ω/km

GB/T 3956 Class 2 Cu max, 120 mm²

AC resistance @90 °C (est.)

≈ 0.196 Ω/km

per core

Current rating in air (30 °C)

310 A​

single-core, touching, in free air

Current rating in tray (30 °C)

295 A​

single-core, spaced 2×OD

Current rating buried in ground (20 °C, thermal resistivity 1.2 K·m/W)

270 A​

single-core, direct buried

Current rating in conduit (30 °C)

255 A​

single-core in conduit

Short-circuit current (1 s, Cu, 250 °C)

≈ 13.20 kA (13,200 A)

120 mm² Cu

Capacitance (core-to-sheath, approx.)

≈ 0.25 µF/km

XLPE insulation

Inductive reactance (approx.)

≈ 0.10 Ω/km

at 50 Hz, single-core

Frequency

50/60 Hz AC

—


Reference values: 1×120 mm² at 310 A, single-phase 230 V → max load ≈ 71.3 kW; three-phase 400 V → max load ≈ 215 kW. Suitable for main distribution feeders, large-capacity equipment, and three-phase primary circuits.


4. Thermal & Mechanical. 90 °C continuous; 250 °C short-circuit (≤ 5 s); ambient −40~+90 °C. Bend ≥ 15 × OD ≈ 267 mm. Non-armored, moderately rigid.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

90 °C (continuous)

Max. short-circuit temp. (≤5 s)

250 °C (Cu conductor, XLPE limit)

Emergency overload temp.

130 °C (≤1 h, not recommended for continuous)

Min. installation ambient temp.

0 °C (PVC sheath); below 0 °C pre-heating required

Service ambient range

−20 °C to +90 °C (XLPE insulation, PVC sheath)

Flexing temp. range

0 °C to +90 °C

Fire survival

Standard (flame retardant C, single cable)

Fire Performance (ZC-YJV — Flame Retardant C)

Property

Value / Requirement

Flame retardant

IEC 60332-3-24 Category C​ (bundled, 3.5 L/m cable volume, self-extinguishing)

Halogen content

Contains halogen (PVC sheath)

Smoke density

Standard (non-low-smoke)

Corrosivity

Corrosive (PVC sheath)

Fire survival (circuit integrity)

Not applicable (standard version)

EMI shielding

None​ (unshielded)


5. Installation Practice & Handling. Use 120 mm² Cu compression lugs. Single core — avoid ferrous conduit (eddy current heating). Site test 2.4 kV DC / 15 min before energizing.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 12 × OD → ≈ 240 mm at Ø20.0 mm

unarmoured single-core

Max. pulling tension

1,800 N (120 mm² × 15 N/mm²)

Cu conductor limit

Direct burial

Suitable​ (with sand bedding and warning tape)

unarmoured — protect from mechanical damage

Surface mounting

Good (cable tray, ladder, cleats)

—

Conduit ID

≥ 25 mm (1 inch)

—

Fixing

cable ties, clips, cleats

—

Impact resistance

Low (PVC sheath only)

protect with conduit in exposed areas

Water resistance

Moisture-resistant (XLPE + PVC)

not waterproof

UV resistance

Poor (PVC degrades in sunlight)

indoor or buried use; for outdoor aerial use UV-stabilised sheath or conduit

Flex life

Low​ (Class 2 stranded, not for repeated flexing)

fixed installation only

Termination note

Crimp lug or compression terminal; no ferrules needed (Class 2 stranded)

—


6. Typical Service Applications. Terminal panel feeders, small submain, equipment mains — where medium-current single-phase or DC power runs from a distribution panel to end equipment.


1x120mm2 Single Core Cable Full Gauge Pure Copper Anti Aging Flame Retardant Power


7. Testing & QA Regime. Routine: conductor DC resistance per length, 3.5 kV AC withstand, insulation resistance, insulation/sheath thickness, dimensional check. Type: XLPE heating test, ZC self-extinguishing, bending test, short-circuit rating.


Cable Parameters


ZC-YJV 1×120 mm² — LV Single-Core Power Cable — Full Parameter Sheet 
ZC flame retardant · compacted Cu / XLPE insulation / PVC sheath · 0.6/1 kV · 90 °C · ≈ 17.8 mm · terminal panel feeders
Parameter Value Unit Remarks / Standard
01 · Identification
Cable type ZC-YJV — single-core LV power cable — Power
Rated voltage (U0/U) 0.6/1 kV LV power
Number of cores 1 × 120 — Single core
Conductor material Compacted annealed copper — Class 2
Insulation material XLPE (cross-linked polyethylene) — 90°C rated
Flame retardant class ZC — Class C — Flame retardant
Sheath material PVC (outer, dark bronze brown) — Power cable
Application Terminal panel feeders, small submain, equipment mains — LV power
02 · Conductor (Compacted Cu)
Conductor type Compacted stranded annealed copper — Class 2
Conductor area 120 mm² Single core
Stranding construction Compacted circular, ~43 wires — Class 2
DC resistance @ 20 °C ≤ 0.253 Ω/km Cu 120 mm²
Conductor weight per km ≈ 1060 kg/km 120 Cu
Conductor diameter ≈ 13.6 mm Compacted
03 · Insulation
Insulation type XLPE (cross-linked PE) — 90°C rated
Insulation thickness ≈ 1.5 mm 0.6/1 kV
Insulated core OD ≈ 16.6 mm Single core
Insulation color Light cream-buff — XLPE
04 · Sheath
Sheath type PVC outer sheath — ZC flame retardant
Sheath thickness ≈ 1.9 mm Power cable
Finished outer diameter ≈ 17.8 mm Overall
Sheath color Dark bronze brown — ZC
05 · Electrical
Rated voltage (U0/U) 0.6/1 kV LV power
Max voltage (Um) 1.2 kV Phase-to-earth
DC resistance @ 20 °C ≤ 0.253 Ω/km Compacted Cu 120
Test voltage (AC) 3.5 kV / 5 min — Routine
Insulation resistance ≥ 36.7 MΩ·km XLPE
Nominal current (ampacity) ≈ 270 A Air, 30°C
Short-circuit current (1s) ≈ 10.6 kA 120 mm² Cu
06 · Thermal
Max conductor temp. 90 °C XLPE rated
Short-circuit temp. 250 °C Max 5 s
Ambient range -40 ~ +90 °C XLPE wide range
Laying temperature ≥ 0 °C XLPE
07 · Mechanical & Construction
Min bending radius (fixed) ≥ 15 × OD ≈ 267 mm Single core
Flexibility Moderately rigid — Single core
Armored No — Non-armored
Cable weight per km ≈ 1180 kg/km Moderate
08 · Factory Advantages
Raw copper sourcing Grade-A electrolytic copper, low oxygen, traceable batch — Consistent resistance
Compacted stranding Precision compaction reduces OD and improves fill factor — Better lug fit
XLPE cross-linking Continuous vulcanized XLPE, uniform wall thickness — Stable dielectric
Flame-retardant compound ZC Class C PVC compound, self-extinguishing — Fire safety
Routine 100% test Conductor resistance, voltage withstand, insulation checked per length — Quality assurance
Custom length Cut to project requirement, custom drum marking available — Flexible supply
Consistent batch Closed production line, stable color and dimension — Repeatable quality
09 · Installation
Laying methods Tray, conduit, terminal panel feeders, equipment mains — Power
Connectors Cu compression lugs, 120 mm² — Power
Site test voltage 2.4 kV DC / 15 min — Before energizing
Bend radius ≥ 15 × OD ≈ 267 mm — Single core
10 · Packing & Applications
Standard supply length 500 m / drum m Power cable
Reel / packing type Wooden drum — Moderate
Surface marking ZC-YJV, 1×120, 0.6/1kV, continuous printing — Marking
Typical use Terminal panel feeders, small submain, equipment mains — LV power


Cable Test Parameters


Test Parameters — ZC-YJV 1×120 mm² LV Power Cable
No. Test Item Test Condition / Method Requirement Type
1 Conductor DC resistance 20 °C, per conductor ≤ 0.253 Ω/km (Cu 120) Routine
2 Voltage test (AC) 3.5 kV AC, 5 min No breakdown Routine
3 Insulation resistance 5000 V DC ≥ 36.7 MΩ·km Routine
4 Insulation thickness Micrometer ≥ 1.5 mm Routine
5 Sheath thickness Micrometer ≥ 1.9 mm Routine
6 Conductor construction Visual / dimensional Compacted Class 2 Routine
7 XLPE heating test 250°C / 10 min No cracks Type
8 Flame retardancy (ZC) Self-extinguishing Class C Passes Type
9 Bending test 15× OD, cycles No damage Type
10 Dimensional check Caliper OD ≈ 17.8 mm Routine
11 Short-circuit rating Calculated / type tested 10.6 kA / 1 s Type
12 Printing legibility Visual Marking readable Routine


Cable Cross Section Structure


1x120mm2 Single Core Cable Full Gauge Pure Copper Anti Aging Flame Retardant Power




Product Structure Introduction — ZR-YJV 1×120 mm²
Layered construction description, from conductor to outer sheath · per GB/T 12706.1 & IEC 60502-1 · CU / XLPE / PVC · 0.6/1 kV

1. Cable Architecture at a Glance
This is a one-conductor, fire-retardant feeder cable for 0.6/1 kV AC systems (Um = 1.2 kV, 50 Hz). The physical layout is strictly concentric: a round stranded copper core sits at the centre, wrapped by a cross-linked polyethylene dielectric, and finished with a halogen-bearing flame-retardant PVC jacket. Design and tests follow GB/T 12706.1 / IEC 60502-1; conductor sizing follows GB/T 3956 / IEC 60228; fire behaviour is governed by GB/T 19666.
Representative envelope: 17.8 mm overall diameter (17.8–19.1 mm per source) and ≈ 1290 kg/km unit weight. The cable is shipped on 100 m drums or coils and suits fixed industrial and utility runs.

2. The Copper Core
Plain annealed copper, normally drawn as Class 2, is stranded into twenty-four 2.52 mm wires (24/2.52) — a classic concentric construction — to realise the nominal 120 mm² section. The multi-wire bundle provides the flexibility required for site handling while capping DC resistance at 0.153 Ω/km at 20 °C. Core diameter lands near 12.4 mm for compact stranding, rising to about 12.6 mm when fully round-lay.

3. The XLPE Dielectric
Over the core, a 1.2 mm layer of cross-linked polyethylene is extruded, bringing the diameter over insulation to ≈ 15.0 mm. Chemical cross-linking converts the thermoplastic into a thermoset network, which lifts the continuous operating limit to 90 °C and the short-circuit limit to 250 °C (max 5 s). This layer provides the primary electrical barrier — volume resistivity ≥ 1×10¹² Ω·cm at 20 °C and a pass at 3.5 kV AC for 5 minutes on the finished length.

4. The PVC Jacket
The outermost 1.5 mm shell is a black, flame-retarded PVC compound (ST2). It absorbs mechanical abuse, resists moisture ingress and delivers the “ZR” fire rating — class ZC per GB/T 19666, demonstrated through the single vertical burn (GB/T 18380.12) and the category-C bunched burn (GB/T 18380.35, char limit 2.5 m). Because the jacket is PVC, the cable releases halogen under fire; projects that demand low smoke and zero halogen should call for WDZ-YJY instead.

5. Deployment Guidance
• Suitable for main feeders, motor circuits and panel supplies at the 120 mm² copper level; standard drum 100 m.  • Keep the bend radius above 20 × OD when laying a single core.  • Do not install at temperatures below 0 °C without pre-warming; normal service range is −20 to +45 °C.  • Always reconcile nominal values with the factory certificate and the GB/T 12706.1 / IEC 60502-1 test report.


ZC-YJV 1×120 mm² — Cross-Section Construction Diagram (Schematic)
Single-core power cable: compacted Cu → XLPE insulation → PVC sheath (ZC) · 0.6/1 kV · ≈ 17.8 mm
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductor Compacted stranded Cu, Class 2, 120 mm² — ≈ 13.6 R ≤ 0.253 Ω/km
2 XLPE insulation Cross-linked polyethylene, cream-buff ≈ 1.5 ≈ 16.6 0.6/1 kV, 90°C
3 PVC outer sheath PVC, ZC flame retardant, dark bronze ≈ 1.9 ≈ 17.8 Outer protection
Key Dimensions & Properties (expanded)
Finished cable diameter ≈ 17.8 mm Overall
Approx. cable mass ≈ 1180 kg/km Moderate
Nominal voltage rating 0.6/1 kV LV power
Max conductor temp. 90 °C XLPE rated
Short-circuit temp. 250 °C Max 5 s
Min bending radius (fixed) ≥ 15 × OD ≈ 267 mm Single core
DC resistance @ 20 °C ≤ 0.253 Ω/km Compacted Cu 120
Test voltage (AC) 3.5 kV / 5 min — Routine
Nominal current (ampacity) ≈ 270 A Air, 30°C
Flame retardant class ZC — Class C — Self-extinguishing
Short-circuit rating (1s) ≈ 10.6 kA 120 mm² Cu
Number of cores 1 — Single core
Application Terminal panel feeders / equipment mains — Medium current
Schematic — not to exact scale. Finished OD ≈ 17.8 mm and weight ≈ 1180 kg/km from cross-referenced industry samples. ZC-YJV 1×120 is a single-core LV power cable for terminal panel feeders with C-class flame retardancy. Values marked (est.) require confirmation against the factory test certificate.


Cable Construction Description


Construction Description — ZC-YJV 1×120 mm² single-core LV power cable
Layer-by-layer single-core power cable: compacted Cu / XLPE insulation / PVC sheath (ZC) · 0.6/1 kV · 90 °C · ≈ 17.8 mm
1. Product Identity & Ratings
ZC-YJV 1×120 is a single-core LV power cable rated 0.6/1 kV (Um = 1.2 kV), 90 °C continuous, ZC C-class flame retardant. Finished OD ≈ 17.8 mm, mass ≈ 1180 kg/km, 500 m wooden drums.
2. Compacted Copper Conductor
Single 120 mm² compacted stranded annealed copper conductor (Class 2). DC resistance ≤ 0.253 Ω/km at 20 °C. Carries ~270 A at 30°C air.
3. XLPE Insulation
Cross-linked polyethylene insulation ≈ 1.5 mm thick, cream-buff color. Rated 90 °C continuous and 250 °C short-circuit.
4. PVC Outer Sheath (ZC)
PVC outer sheath ≈ 1.9 mm thick, C-class flame retardant, dark bronze brown. Provides mechanical protection and self-extinguishing behavior.
5. Factory Advantages
• Grade-A low-oxygen copper with traceable batch.  • Precision compaction for stable OD.  • Continuous vulcanized XLPE with uniform wall.  • ZC self-extinguishing compound.  • 100% routine resistance/voltage/insulation test.  • Custom length and drum marking.
6. Site Handling Notes
• Bend radius 15×OD (≈ 267 mm).  • Use 120 mm² Cu compression lugs.  • Single core — avoid ferrous conduit.  • Site test 2.4 kV DC before energizing.


8. Factory Advantages.

  • Grade-A low-oxygen copper with traceable batch, consistently meeting DC resistance limits.
  • Precision compaction reduces outer diameter and improves fill factor for cleaner lug fit.
  • Continuous vulcanized XLPE with uniform wall thickness and stable dielectric.
  • ZC self-extinguishing PVC compound that stops burning once the flame source is removed.
  • 100% routine testing of resistance, voltage withstand, and insulation on every length.
  • Custom length cutting and optional custom drum marking to project requirement.
  • Closed production line for stable color, dimension, and repeatable batch quality.

1x120mm2 Single Core Cable Full Gauge Pure Copper Anti Aging Flame Retardant Power


9. Packaging, Storage & Logistics. 500 m per wooden drum; continuous surface marking (ZC-YJV, 1×120, 0.6/1kV). Store dry, indoor, away from direct sunlight.


1x120mm2 Single Core Cable Full Gauge Pure Copper Anti Aging Flame Retardant Power


10. Procurement Specification. State "ZC-YJV 1×120" + required length, specify ZC flame retardant, and confirm against the factory test certificate for the batch.


ZC-YJV 1×120 mm² Power Cable
Frequently Asked Questions (FAQ)
Flame-Retardant Class C · XLPE Insulated · PVC Sheathed · Copper Conductor · 0.6/1 kV

Product Basics

Q1. What does the model “ZC-YJV” mean?
“Z” stands for flame-retardant, “C” denotes Class C flame-retardant performance, “YJ” means XLPE (cross-linked polyethylene) insulation, and “V” means PVC sheath. ZC-YJV is a copper-core, Class C flame-retardant, XLPE-insulated, PVC-sheathed low-voltage power cable.
Q2. What does “1×120 mm²” indicate?
“1” means a single-core cable. “120 mm²” is the nominal cross-sectional area of the copper conductor. This size is commonly used for main power feeders, transformer secondary connections, and high-current distribution circuits in large commercial and industrial projects.
Q3. What is the rated voltage?
The rated voltage U₀/U is 0.6/1 kV (0.6 kV phase-to-earth, 1 kV phase-to-phase), designed for low-voltage power transmission and distribution systems.
Q4. What materials are used in construction?
Conductor: plain copper, Class 2 stranded. Insulation: cross-linked polyethylene (XLPE). Outer sheath: flame-retardant PVC. Standard ZC-YJV is unarmored. For direct burial or locations requiring mechanical protection, armored variants such as ZC-YJV22 (double steel tape) or ZC-YJV32 (fine steel wire) are recommended.

Technical Specifications

Q5. What is the maximum operating temperature?
The maximum continuous conductor temperature is 90 °C. During short-circuit events, the conductor may reach up to 250 °C for no more than 5 seconds. XLPE insulation provides excellent thermal stability and high current-carrying capacity for heavy-duty power distribution.
Q6. What is the typical current-carrying capacity?
For a 1×120 mm² copper XLPE cable, the ampacity is approximately 310–390 A when installed in free air at 30 °C ambient. Lower ratings apply when buried, installed in conduit, grouped with other cables, or at elevated ambient temperatures. For precise engineering design, consult the manufacturer's ampacity tables (GB/T 16895 / IEC 60364) and apply appropriate derating factors.
Q7. What is the conductor DC resistance?
The maximum DC resistance of a 120 mm² Class 2 copper conductor at 20 °C is approximately 0.153 Φ/km (annealed copper), per GB/T 3956 / IEC 60228. The exact value should be verified against the factory test report for each production batch.

Installation & Applications

Q8. What is the minimum bending radius?
For single-core unarmored cables of this size, the minimum bending radius is 20 times the cable outer diameter (20D) during installation. Large cross-section cables are stiff and require proper pulling equipment and careful handling to avoid insulation and sheath damage. D = actual outer diameter.
Q9. What are the typical applications?
Common uses include: main incoming feeders in high-rise commercial buildings; connection between low-voltage distribution transformers and main switchgear; supply to large motors, UPS systems, and central HVAC plants; and primary power distribution in industrial facilities and infrastructure projects where Class C flame-retardant performance is required.
Q10. Which standards and certifications apply?
Manufactured in accordance with GB/T 12706 (equivalent to IEC 60502), with conductor compliance to GB/T 3956 / IEC 60228 and flame-retardant testing per GB/T 18380 / IEC 60332-3. Common certifications include CCC (China), CE (Europe), ISO 9001, RoHS, and VDE/TUV for specific international markets.