logo
Anhui Tongdu International Trade Co., Ltd.
Online Service

Online Service

Contact Person
+86 19056002718
WeChat QR Code
Follow Us

ZR-YJV Single Core Cable 1 X 300mm2 Flame Retardant 0.6/1kV Solid Copper XLPE Insulation

ZR-YJV Single Core Cable 1 X 300mm2 Flame Retardant 0.6/1kV Solid Copper XLPE Insulation

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
ZR-YJV 1*300mm²

Trading Properties

moq
1 Meter
payment method
L/C,T/T
supply capacity
10000 meters per month

Product Summary

ZR-YJV 1*300mm² Flame Retardant Single Core Cable, 0.6/1kV Solid Copper, XLPE Insulation PVC Jacket for Construction Power Cable Designation & Meaning Code Meaning ZC Flame retardant C — IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 1×300 mm² Single core, 300 ...

Product Details

Highlight:

ZR-YJV Single Core Cable

,

Single Core Cable 1 x 300mm2

,

1kV Low Voltage Power Cable

Conductor​:
Bare Annealed Copper, Class 2 Stranded Circular, 61×∅2.52 Mm​ (typical), Conductor Ø ≈ 22.4 Mm
Conductor nominal area:
300 Mm²
Conductor construction:
Class 2, 61×∅2.52 Mm​ Min. 61 Wires Per GB/T 3956 (>240 Mm²)
Conductor diameter (approx.):
22.4mm
Insulation:
XLPE Compound, Extruded
Insulation thickness (nominal):
1.4 Mm​ (GB/T 12706.1, 300 Mm² Class)
Diameter over insulation (approx.):
25.2 Mm (22.4 + 2×1.4)
Filler / binder:
Flame-retardant (FR) Non-hygroscopic Tape / PP Mesh​ (single-core: Thin FR Binder, No Filler Body)
Outer sheath:
Flame-retardant PVC Compound (ZR Grade)​ — Contains Halogen, Not Low-smoke
Sheath thickness (nominal)​:
1.4 Mm​ (single-core; Some Makers Use 1.5 Mm For 300 Mm² — Verify Per Factory)
Overall cable diameter:
31.5 – 32.5 Mm​,PVC Density; Use 32.0 Mm For Design
Approx. weight:
2,350 – 2,500 Kg/km​,PVC Heavier Than PO; Use ≈ 2,420 Kg/km
Long-term service temperature:
90 °C
Short-circuit temperature (≤5 s):
250 °C
Emergency overload:
105–130 °C (limited Duration)
Routine test:
3.5 KV AC / 5 Min; Type Test 4.0 KV
Volume resistivity @90 °C:
≥ 10¹² Ω·cm

Product Description

ZR-YJV 1*300mm² Flame Retardant Single Core Cable, 0.6/1kV Solid Copper, XLPE Insulation PVC Jacket for Construction Power

Cable Designation & Meaning

Code

Meaning

ZC

Flame retardant C — IEC 60332-3-24, Category C

YJ

Cross-linked polyethylene (XLPE) insulation

V

PVC sheath

1×300 mm²

Single core, 300 mm² copper conductor


Construction: Single Class 2 stranded copper conductor, XLPE insulation, PVC outer sheath (no armour, no shield).



ZR-YJV Single Core Cable 1 X 300mm2 Flame Retardant 0.6/1kV Solid Copper XLPE Insulation


ZC-YJV 1×300 mm² v2 — LV Large Single-Core Power Cable — Specification & Engineering Data

1. Overview & Ratings. ZC-YJV 1×300 v2 is a large single-core LV power cable rated 0.6/1 kV (Um = 1.2 kV), 90 °C continuous. Built per GB/T 12706.1 / IEC 60502-1, ZC C-class flame retardant per GB/T 19666. A single 300 mm² compacted stranded copper conductor (Class 2) enclosed in light blue-gray XLPE insulation and dark navy teal PVC outer sheath. Finished OD ≈ 25.0 mm, ≈ 2850 kg/km, 300 m reinforced wooden drums.


2. Construction Stack (Conductor → Outer).

Layer Build Wall Diameter
Conductor Compacted stranded Cu, Class 2, 300 mm² — ≈ 20.5 mm
XLPE insulation Cross-linked polyethylene, light blue-gray ≈ 1.8 mm ≈ 24.1 mm
PVC outer sheath PVC, ZC flame retardant, dark navy teal ≈ 2.2 mm ≈ 25.0 mm (finished)


3. Electrical Characteristics. DC resistance ≤ 0.124 Ω/km at 20 °C (compact Cu 300 mm²); test voltage 3.5 kV AC / 5 min; insulation resistance ≥ 36.7 MΩ·km. Nominal ampacity ≈ 540 A (air, 30 °C). Short-circuit rating ≈ 25.5 kA / 1 s.

Insulation & Sheath Data

Property

Value

Insulation material

XLPE (cross-linked polyethylene), Type TR-XLPE

Outer sheath material

PVC (polyvinyl chloride), Type ST₂

Long-term service temp.

90 °C (continuous, XLPE insulation)

Short-circuit temp. (≤5 s)

250 °C (Cu conductor limit for XLPE)

Emergency overload temp.

130 °C (short term, ≤1 h)

Test voltage AC (5 min)

3.5 kV (routine test, 0.6/1 kV class)

Dielectric strength

≥ 20 kV/mm (room temp.)

Volume resistivity @20 °C

≥ 1×10¹⁴ Ω·cm

Shield

None​ (unshielded design)

Electrical Parameters

Parameter

Value

Note

Rated voltage U₀/U

0.6 / 1 kV

GB/T 12706.1 / IEC 60502-1

Max. system voltage

1.2 kV AC

—

Test voltage AC (5 min)

3.5 kV

Routine test (conductor-to-sheath)

DC resistance @20 °C

≤ 0.0601 Ω/km

GB/T 3956 Class 2 Cu max, 300 mm²

AC resistance @90 °C (est.)

≈ 0.077 Ω/km

—

Current rating in air (30 °C)

530 A​

single-core, touching, in free air

Current rating in tray (30 °C)

505 A​

spaced 2×OD

Current rating buried in ground (20 °C, thermal resistivity 1.2 K·m/W)

470 A​

direct buried

Current rating in conduit (30 °C)

450 A​

—

Short-circuit current (1 s, Cu, 250 °C)

≈ 33.0 kA (33,000 A)

300 mm² Cu

Capacitance (core-to-sheath, approx.)

≈ 0.28 µF/km

XLPE insulation

Inductive reactance (approx.)

≈ 0.11 Ω/km

at 50 Hz

Frequency

50/60 Hz AC

—


Reference values: 1×300 mm² at 530 A, single-core used as phase in three-phase 400 V system → max load per phase ≈ 212 kW​ (cos φ = 0.8); as single-phase 230 V → max load ≈ 122 kW. Suitable for main distribution, transformer connections, and high-current single-core circuits.


4. Thermal & Mechanical. 90 °C continuous; 250 °C short-circuit (≤ 5 s); ambient −40~+90 °C. Bend ≥ 15 × OD ≈ 375 mm. Non-armored, very rigid.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

90 °C (continuous)

Max. short-circuit temp. (≤5 s)

250 °C (Cu conductor, XLPE limit)

Emergency overload temp.

130 °C (≤1 h, not recommended for continuous)

Min. installation ambient temp.

0 °C (PVC sheath); below 0 °C pre-heating required

Service ambient range

−20 °C to +90 °C (XLPE insulation, PVC sheath)

Flexing temp. range

0 °C to +90 °C

Fire survival

Standard (flame retardant C, single cable)

Fire Performance (ZC-YJV — Flame Retardant C)

Property

Value / Requirement

Flame retardant

IEC 60332-3-24 Category C​ (bundled, 3.5 L/m cable volume, self-extinguishing)

Halogen content

Contains halogen (PVC sheath)

Smoke density

Standard (non-low-smoke)

Corrosivity

Corrosive (PVC sheath)

Fire survival (circuit integrity)

Not applicable (standard version)

EMI shielding

None​ (unshielded)



ZR-YJV 1×300 mm² Flame-Retardant Copper-Conductor XLPE-Insulated PVC-Sheathed Power Cable — Product Parameters (0.6/1 kV)
Construction: CU / XLPE / PVC  •  Standards: GB/T 12706.1, IEC 60502-1 (cable), GB/T 3956 (conductor), GB/T 19666 & GB/T 18380 (flame retardance)  •  Nominal values for reference — confirm against factory test certificate
No. Category Parameter Value Unit Notes / Standard Reference
A. Product Identification
1 Identification Product name Flame-retardant copper-conductor XLPE-insulated PVC-sheathed power cable — Designation ZR-YJV; "ZR" = flame-retardant (halogen-containing)
2 Identification Model designation ZR-YJV 1×300 — Cu / XLPE / PVC
3 Identification Design standards GB/T 12706.1; IEC 60502-1 — Conductor: GB/T 3956 / IEC 60228; flame retardance: GB/T 19666, GB/T 18380; safety: CCC / production licence
4 Identification Rated voltage U0/U 0.6/1 kV Max system voltage Um = 1.2 kV
5 Identification Rated frequency 50 Hz AC power distribution
6 Identification Number of cores 1 — Single-core cable
7 Identification Nominal cross-sectional area 300 mm² Nominal conductor cross-section per GB/T 3956
B. Cable Construction (from conductor to outer sheath)
8 Conductor Material Plain annealed copper (Cu) — High-conductivity electrolytic / oxygen-free copper
9 Conductor Conductor class Class 1 or Class 2 (typical: Class 2, stranded) — GB/T 3956 / IEC 60228
10 Conductor Typical stranding construction 61 wires × 2.5 mm (61/2.5, lay-up 1+6+12+18+24) — Class 2 round stranded; nominal section ≈ 300 mm²
11 Conductor Conductor diameter ≈ 18.7 mm ≈ 18.7 mm compact (18.7–19.2 mm across stranding practice)
12 Conductor Max. DC resistance of conductor at 20 °C 0.0601 Ω/km GB/T 3956, Class 2 copper; acceptance criterion for 300 mm²
13 Insulation Material Cross-linked polyethylene (XLPE) — Thermally cross-linked; natural/transparent colour
14 Insulation Nominal insulation thickness 1.8 mm GB/T 12706.1 / IEC 60502-1 (0.6/1 kV, 300 mm²)
15 Insulation Diameter over insulation ≈ 22.3 mm ≈ 18.7 + 2 × 1.8 (calculated, compact conductor)
16 Sheath Material Flame-retardant polyvinyl chloride (PVC, ST2 type) — Colour: black (or as ordered)
17 Sheath Nominal sheath thickness 2.5 mm GB/T 12706.1 / IEC 60502-1 (cabhr table; ahtk lists 1.9)
18 Dimensions Approx. overall diameter 27.3 mm ≈ 27.3 mm (27.3–28.4 mm across sources: cabhr 27.3; ahtk 28.4; Meihe 28.24)
19 Dimensions Approx. cable weight ≈ 3076 kg/km cabhr 3076; ahtk 3056; Meihe 2960 (copper core alone ≈ 2667 kg/km)
C. Electrical Performance
20 Electrical Max. DC conductor resistance at 20 °C 0.0601 Ω/km GB/T 3956; routine measurement
21 Electrical Power-frequency withstand voltage (routine test) 3.5 kV / 5 min, no breakdown — AC 50 Hz; per GB/T 12706.1 / IEC 60502-1
22 Electrical Insulation resistance (finished cable, 20 °C) ≥ 36.7 MΩ·km Typical finished-cable reference for 0.6/1 kV XLPE cables; varies with geometry and manufacturer test method
23 Electrical XLPE volume resistivity at 20 °C ≥ 1 × 10¹² Ω·cm Material-level requirement (manufacturer reference)
24 Electrical Capacitance (single-core, approx.) ≤ 0.45 μF/km Manufacturer reference value
25 Electrical Reference ampacity — in air, 30 °C, single core ≈ 720 A cabhr table (720 A); depends on laying, grouping, ambient — apply correction factors per GB/T 16895 / IEC 60364
26 Electrical Reference ampacity — direct burial, 25 °C ≈ 630 A cabhr table; depends on soil thermal resistivity and depth
D. Thermal Performance
27 Thermal Max. continuous conductor temperature 90 °C XLPE insulation temperature class
28 Thermal Max. conductor temperature under short-circuit (≤ 5 s) 250 °C Per GB/T 12706.1 / IEC 60502-1
29 Thermal Ambient service temperature range -20 to +45 °C Per Qifan datasheet family; check project specification
30 Thermal Min. installation (laying) temperature 0 °C Pre-heat the cable if ambient is below 0 °C
E. Flame Retardance (ZR)
31 Flame retardance Flame-retardant class ZC (class C) by default for "ZR" — GB/T 19666; ZA / ZB available on request; halogen-containing PVC (not LSZH)
32 Flame retardance Single-cable vertical flame-spread test Pass — GB/T 18380.12
33 Flame retardance Bunched flame-spread test (class C) Char extent ≤ 2.5 m above burner bottom edge — GB/T 18380.35: non-metallic volume ≥ 1.5 L/m; flame application 20 min
34 Flame retardance Halogen content Halogen-containing (PVC) — For low-smoke, zero-halogen requirement select WDZ-YJY (LSZH) type
F. Installation
35 Installation Min. bending radius — single-core cable 20 × OD — Qifan & Huaneng datasheets; OD = actual cable diameter
36 Installation Laying methods Conduit, tray, cable trench, tunnel, duct, supported/suspended aerial — Also direct burial with mechanical protection where permitted
37 Installation Site withstand test after installation DC 4U0 = 2.4 kV, 15 min (recommended) — Per utility procurement standard Q/GDW 13244.1-2018; practice may vary by project
G. Packing & Delivery
38 Packing Standard delivery length 100 m per coil/drum (or as ordered) — Typical industry practice; custom lengths available
39 Packing Cable marking Model, rated voltage, manufacturer, year of manufacture, sequential length marks — Per GB/T 6995 / project specification
40 Packing Packing form Wooden drum / coil / export packing — As per customer requirement


5. Installation Practice & Handling. Use 300 mm² Cu compression lugs. Single core — do NOT run in ferrous conduit (eddy currents). Site test 2.4 kV DC / 15 min before energizing. At 2850 kg/km, very heavy — requires drum jacks and lifting equipment.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 12 × OD → ≈ 362 mm at Ø30.2 mm

unarmoured single-core

Max. pulling tension

4,500 N (300 mm² × 15 N/mm²)

Cu conductor limit

Direct burial

Suitable​ (with sand bedding and warning tape)

unarmoured — protect from mechanical damage

Surface mounting

Good (cable tray, ladder, cleats)

—

Conduit ID

≥ 40 mm

—

Fixing

cable ties, clips, cleats

—

Impact resistance

Low (PVC sheath only)

protect with conduit in exposed areas

Water resistance

Moisture-resistant (XLPE + PVC)

not waterproof

UV resistance

Poor (PVC degrades in sunlight)

indoor or buried use; for outdoor aerial use UV-stabilised sheath or conduit

Flex life

Low​ (Class 2 stranded, not for repeated flexing)

fixed installation only

Termination note

Crimp lug or compression terminal; no ferrules needed (Class 2 stranded)

—


6. Flame Resistance. Passes GB/T 18380.12 single burn and class-C bunched burn GB/T 18380.35 (char ≤ 2.5 m) → ZC per GB/T 19666. PVC carries halogen — choose WDZ-YJY for LSZH specs.


Flame Retardant Performance Data Sheet — ZR-YJV 0.6/1 kV 1×300 mm²
ZR = Legacy flame-retardant mark; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC)
1. GENERAL INFORMATION
1 Cable designation ZR-YJV 1×300 mm² Cu / XLPE / PVC (FR) GB/T 12706.1
2 Rated voltage U₀/U 0.6 / 1 kV Uₘ = 1.2 kV IEC 60502-1
3 Flame retardant class Class C (default for ZR) Bundled combustion, char ≤ 2.5 m GB/T 19666-2019
4 Conductor Cu, Class 2, 61×∅2.52 mm Ø ≈ 22.4 mm GB/T 3956
5 Insulation / Sheath XLPE 1.4 mm / PVC (FR) 1.4 mm Black GB/T 12706.1
2. FLAME RETARDANT CLASSIFICATION (ZR = Class C)
Level Designation example Non-metallic volume (L/m) Flame application Char length (max)
A  ZA-YJV / WDZA ≥ 7.0 40 min ≤ 2.0 m
B ZB-YJV / WDZB 3.5 40 min ≤ 2.5 m
C  ZC-YJV / ZR-YJV 1.5 20 min ≤ 2.5 m
D  ZD-YJV 0.5 20 min ≤ 2.5 m
3. FLAME RETARDANT TEST ITEMS & TECHNICAL LIMITS (this product = Class C)
No. Test item Standard / Method Requirement / Limit (Class C) Result
1 Bunched flame propagation (vertical) GB/T 18380.3 / IEC 60332-3-24 (Cat. C) Char length ≤ 2.5 m above top of burner; self-extinguishing within 1 h Pass
2 Single-cable flame (vertical) GB/T 18380.1 / IEC 60332-1-2 No sustained burning after removal of flame; char ≤ 50 mm × 50 mm Pass
3 Non-metallic material volume (test specimen) GB/T 18380.3 (Cat. C) 1.5 L/m of cable length 1.5 L/m
4 Flame source duration (Cat. C) GB/T 18380.3 20 min (supply air 5000 L/min, propane 600 mm³/h) 20 min
5 pH value of combustion gases GB/T 17650.2 / IEC 60754-2 ≥ 4.3 (informative for ZR; certified for WDZ) ≥ 4.3*
6 Conductivity of acid gases GB/T 17650.2 / IEC 60754-2 ≤ 10 µS/mm (informative for ZR; certified for WDZ) ≤ 10*
7 Halogen acid gas emission (HCI) GB/T 17650.1 / IEC 60754-1 ≤ 5 % (informative for ZR; PVC sheath contains Cl) Contains Cl*
8 Smoke density (transmittance, min.) GB/T 17651 / IEC 61034-2 ≥ 60 % (informative for ZR; certified for WDZ) Not certified*
9 Oxygen index (LOI, min.) GB/T 2406 / IEC 60754 ref. ≥ 30 % (typical for FR-PVC ≥ 32 %) ≥ 32 %
10 Flame retardant in insulation & sheath FR-PVC + FR-XLPE compound Sb₂O₃ / Al(OH)₃ based FR system Compliant
4. NOTES
* Items 5–8 marked with * are INFORMATIVE for plain ZR (Class C) cable. ZR-YJV uses flame-retardant PVC which contains halogen; pH / conductivity / smoke / halogen are NOT certified limits.
** For certified halogen-free + low-smoke performance, use WDZ-YJY. For circuit-integrity (fire-survival), use NH-ZR-YJV.
*** ZR is a legacy GB prefix; modern specifications use ZC (Class C). ZR-YJV ≈ ZC-YJV in flame-retardant performance.


Flame Retardant Class Comparison — ZR (Class C) vs WDZ vs Z (A/B)
Property ZR-YJV (this, C) WDZ-YJV WDZA-YJY (A) NH-ZR-YJV Ordinary YJV
Flame retardant Class C Class C Class A (最高) Class C None
Halogen-free (W) No (PVC含Cl) Yes Yes No (Include Mica Tape) No
Low smoke (D) No Yes (≥60%) Yes (≥60%) Yes No
Fire-survival (NH) No No No Yes (90 min, 830℃) No
Smoke corrosivity Corrosive HCI Non-corrosive Non-corrosive Low corrosivity Corrosive
Typical use General, cost-saving Metro/Hospital Tunnel/Underground Emergency circuits General
Relative price 1.0 (base) ~1.15× ~1.30× ~1.40× 1.0 (base)


7. Test Regime. Routine: DC resistance, 3.5 kV/5 min, dimensional audit (ins. ≥ 1.8 mm, sheath ≥ 2.5 mm). Sample: XLPE hot-set (200 ± 3 °C / 15 min / 0.2 MPa). Type: flame + bending. Site: DC 4U0 = 2.4 kV / 15 min (Q/GDW 13244.1-2018 practice).


Cable Parameters


ZC-YJV 1×300 mm² — LV Single-Core Power Cable— Full Parameter Sheet
ZC flame retardant · compacted Cu / XLPE insulation / PVC sheath · 0.6/1 kV · 90 °C · ≈ 25.0 mm · large single core power
Parameter Value Unit Remarks / Standard
01 · Identification
Cable type ZC-YJV — large single-core LV power cable — Power
Rated voltage (U0/U) 0.6/1 kV LV power
Number of cores 1 × 300 — Single core
Conductor material Compacted annealed copper — Class 2
Insulation material XLPE (cross-linked polyethylene) — 90°C rated
Flame retardant class ZC — Class C — GB/T 19666
Sheath material PVC (outer, dark navy teal) — Power cable
Standard GB/T 12706.1 / IEC 60502-1 — LV power
Application Main switchgear, transformer bus, large feeders — LV power
02 · Conductor (Compacted Cu)
Conductor type Compacted stranded annealed copper — Class 2
Conductor area 300 mm² Single core
Stranding construction Compacted circular, ~61 wires — Class 2
DC resistance @ 20 °C ≤ 0.124 Ω/km Cu 300 mm²
Conductor weight per km ≈ 2720 kg/km 300 Cu
Conductor diameter ≈ 20.5 mm Compacted
03 · Insulation
Insulation type XLPE (cross-linked PE) — 90°C rated
Insulation thickness ≈ 1.8 mm 0.6/1 kV
Insulated core OD ≈ 24.1 mm Single core
Insulation color Light blue-gray — XLPE
04 · Sheath
Sheath type PVC outer sheath — ZC flame retardant
Sheath thickness ≈ 2.2 mm Power cable
Finished outer diameter ≈ 25.0 mm Overall
Sheath color Dark navy teal — ZC
05 · Electrical
Rated voltage (U0/U) 0.6/1 kV LV power
Max voltage (Um) 1.2 kV Phase-to-earth
DC resistance @ 20 °C ≤ 0.124 Ω/km Compacted Cu 300
Test voltage (AC) 3.5 kV / 5 min — Routine
Insulation resistance ≥ 36.7 MΩ·km XLPE
Nominal current (ampacity) ≈ 540 A Air, 30°C
Short-circuit current (1s) ≈ 25.5 kA 300 mm² Cu
06 · Thermal
Max conductor temp. 90 °C XLPE rated
Short-circuit temp. 250 °C Max 5 s
Ambient range -40 ~ +90 °C XLPE wide range
Laying temperature ≥ 0 °C XLPE
07 · Mechanical & Construction
Min bending radius (fixed) ≥ 15 × OD ≈ 375 mm Large single core
Flexibility Very rigid — Large single core
Armored No — Non-armored
Cable weight per km ≈ 2850 kg/km Very heavy
08 · Installation
Laying methods Main switchgear, transformer bus, indoor tray — Power
Connectors Cu compression lugs, 300 mm² — Power
Site test voltage 2.4 kV DC / 15 min — Before energizing
Bend radius ≥ 15 × OD ≈ 375 mm — Large single core
09 · Packing
Standard supply length 300 m / drum m Heavy power cable
Reel / packing type Wooden drum, reinforced — Very heavy
Surface marking ZC-YJV, 1×300, 0.6/1kV, GB/T 12706.1 — Continuous printing
Approx. cable weight ≈ 2850 kg/km Large single core power
10 · Applications
Typical use Main switchgear bus, transformer secondary, large LV feeders — LV power
Max system voltage 1.2 kV Um
Application level Main LV power distribution — Very high current


Cable Testing Parameters


Test Parameters — ZC-YJV 1×300 mm² LV Power Cable 
No. Test Item Test Condition / Method Requirement Type
1 Conductor DC resistance GB/T 3956, 20 °C ≤ 0.124 Ω/km (Cu 300) Routine
2 Voltage test (AC) 3.5 kV AC, 5 min No breakdown Routine
3 Insulation resistance 5000 V DC ≥ 36.7 MΩ·km Routine
4 Insulation thickness Micrometer ≥ 1.8 mm Routine
5 Sheath thickness Micrometer ≥ 2.2 mm Routine
6 Conductor construction Visual / dimensional Compacted Class 2 Routine
7 XLPE heating test 250°C / 10 min No cracks Type
8 Flame retardancy (ZC) GB/T 19666, Class C Passes Type
9 Bending test 15× OD, cycles No damage Type
10 Dimensional check Caliper OD ≈ 25.0 mm Routine
11 Short-circuit rating Calculated / type tested 25.5 kA / 1 s Type
12 Printing legibility Visual Marking readable Routine


Cable Cross Section Structure


ZR-YJV Single Core Cable 1 X 300mm2 Flame Retardant 0.6/1kV Solid Copper XLPE Insulation

ZC-YJV 1×300 mm² — Cross-Section Construction Diagram (Schematic) 
Large single-core power cable: compacted Cu → XLPE insulation → PVC sheath (ZC) · 0.6/1 kV · ≈ 25.0 mm
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductor Compacted stranded Cu, Class 2, 300 mm² — ≈ 20.5 R ≤ 0.124 Ω/km
2 XLPE insulation Cross-linked polyethylene, light blue-gray ≈ 1.8 ≈ 24.1 0.6/1 kV, 90°C
3 PVC outer sheath PVC, ZC flame retardant, dark navy teal ≈ 2.2 ≈ 25.0 Outer protection
Key Dimensions & Properties (expanded)
Finished cable diameter ≈ 25.0 mm Overall
Approx. cable mass ≈ 2850 kg/km Very heavy
Nominal voltage rating 0.6/1 kV LV power
Max conductor temp. 90 °C XLPE rated
Short-circuit temp. 250 °C Max 5 s
Min bending radius (fixed) ≥ 15 × OD ≈ 375 mm Large single core
DC resistance @ 20 °C ≤ 0.124 Ω/km Compacted Cu 300
Test voltage (AC) 3.5 kV / 5 min — Routine
Nominal current (ampacity) ≈ 540 A Air, 30°C
Flame retardant class ZC — Class C — GB/T 19666
Short-circuit rating (1s) ≈ 25.5 kA 300 mm² Cu
Number of cores 1 — Single core
Standard GB/T 12706.1 / IEC 60502-1 — LV power
Application Main switchgear / transformer bus — Very high current
Schematic — not to exact scale. Finished OD ≈ 25.0 mm and weight ≈ 2850 kg/km from cross-referenced industry samples. ZC-YJV 1×300 v2 is a large single-core LV power cable for main switchgear and transformer bus with C-class flame retardancy. Values marked (est.) require confirmation against the factory test certificate.


Cable Construction Description


Construction Description — ZC-YJV 1×300 mm²  large single-core LV power cable
Layer-by-layer large single-core power cable: compacted Cu / XLPE insulation / PVC sheath (ZC) · 0.6/1 kV · 90 °C · ≈ 25.0 mm
1. Product Identity & Ratings
ZC-YJV 1×300 v2 is a large single-core LV power cable rated 0.6/1 kV (Um = 1.2 kV), 90 °C continuous. Built per GB/T 12706.1 / IEC 60502-1, ZC C-class flame retardant per GB/T 19666. Finished OD ≈ 25.0 mm, mass ≈ 2850 kg/km, 300 m reinforced wooden drums.
2. Compacted Copper Conductor
Single 300 mm² compacted stranded annealed copper conductor (Class 2). DC resistance ≤ 0.124 Ω/km at 20 °C. Compacted for reduced outer diameter and better lug fit. Carries ~540 A at 30°C air.
3. XLPE Insulation
Cross-linked polyethylene insulation ≈ 1.8 mm thick. Light blue-gray color. Rated 90 °C continuous and 250 °C short-circuit.
4. PVC Outer Sheath (ZC)
PVC outer sheath ≈ 2.2 mm thick, C-class flame retardant (ZC). Dark navy teal color. Provides mechanical protection and flame-retardant properties.
5. Site Handling & Operational Notes
• Bend radius 15×OD (≈ 375 mm).  • Use 300 mm² Cu compression lugs.  • At 2850 kg/km, very heavy — needs drum jacks.  • Single core — do not run in ferrous conduit.  • Site test 2.4 kV DC before energizing.



ZR-YJV 1×300 mm² — Test / Verification Parameters (per GB/T 12706.1 & IEC 60502-1)
Test Stage Test Item Method / Standard Requirement / Acceptance Criterion Notes
Routine test Conductor DC resistance measurement GB/T 3956 (IEC 60228) ≤ 0.0601 Ω/km at 20 °C Measured on every production length
Routine test Power-frequency withstand voltage GB/T 12706.1 / IEC 60502-1 3.5 kV AC, 5 min, no breakdown Applied between conductor and water/earth; 50 Hz
Routine test Construction check — insulation & sheath thickness, outer diameter GB/T 2951 Within GB/T 12706.1 tolerances Insulation ≥ 1.8 mm nominal; sheath ≥ 2.5 mm nominal
Sample test Hot set (thermal elongation) test — XLPE insulation GB/T 12706.1 §16.3.13 / GB/T 2951.11 200 ± 3 °C, 15 min, stress 0.2 MPa: elongation under load ≤ 175 %; permanent elongation after cooling ≤ 15 % Verifies degree of cross-linking
Sample test Conductor construction & diameter check GB/T 3956 Class 2; 61 × 2.5 mm; Ø ≈ 18.7 mm Sampled per batch
Type test Single-cable vertical flame-spread test (flame retardance) GB/T 18380.12 No flame spread; charring does not reach top reference point ZR / ZC flame-retardant property
Type test Bunched flame-spread test, class C GB/T 18380.35 Char extent ≤ 2.5 m above burner bottom edge; flame application 20 min; non-metallic volume ≥ 1.5 L/m Class ZC per GB/T 19666
Type test Bending test (mechanical) GB/T 12706.1 Bend around specified mandrel without insulation/sheath damage Mandrel diameter related to cable OD
Post-installation DC withstand test after installation Q/GDW 13244.1-2018 (recommended practice) 4U0 = 2.4 kV DC, 15 min, no breakdown For new installations; verify project specification
Optional Insulation resistance measurement at 20 °C Manufacturer test method ≥ 36.7 MΩ·km (typical finished-cable value) Not a routine item in GB/T 12706.1; confirm with factory
Optional XLPE volume resistivity at 20 °C Manufacturer / material test ≥ 1 × 10¹² Ω·cm Material-level reference


8. Installation Do's & Don'ts. Do keep bends ≥ 20 × OD, use rollers and smooth radii, protect from UV; don't drag over sharp metal, flex continuously, or energise before the site DC test. Verify the actual core Ø before connector selection.


Size

Insulation

Sheath

OD (mm)

Weight (kg/km)

R₂₀ (Ω/km)

Ampacity (A) air / buried

1×16

0.7

1.4

9.4

~215

≤1.15

105 / 95

1×25

0.9

1.4

11.2

~310

≤0.727

140 / 130

1×35

0.9

1.4

13.2

~410

≤0.524

175 / 160

1×50

1.0

1.4

15.6

~545

≤0.387

210 / 190

1×70

1.1

1.4

17.8

~720

≤0.268

270 / 245

1×95

1.1

1.4

20.0

~950

≤0.193

330 / 300

1×120

1.1

1.4

22.0

~1,140

≤0.153

385 / 350

1×150

1.2

1.4

24.0

~1,360

≤0.124

440 / 400

1×185

1.2

1.4

26.0

~1,600

≤0.0991

505 / 460

1×240

1.2

1.4

29.0

~1,980

≤0.0754

590 / 535

1×300​

1.4​

1.4​

32.0​

~2,420​

≤0.0601​

685 / 620



9. Typical Service Applications. Main switchgear bus, transformer secondary, large LV feeders, main building power distribution — where very high-current single-phase or DC power is required.


ZR-YJV Single Core Cable 1 X 300mm2 Flame Retardant 0.6/1kV Solid Copper XLPE Insulation


10. Packaging, Storage & Logistics. 300 m per reinforced wooden drum (shorter due to weight). Continuous marking: ZC-YJV, 1×300, 0.6/1kV, GB/T 12706.1. Store dry, indoor. Very heavy drums — use lifting equipment.


11. Procurement Specification. State "ZC-YJV 1×300" + length. Specify ZC flame retardant requirement. Confirm against factory test certificate.


ZR-YJV Single Core Cable 1 X 300mm2 Flame Retardant 0.6/1kV Solid Copper XLPE Insulation


ZR-YJV Single Core Cable 1 X 300mm2 Flame Retardant 0.6/1kV Solid Copper XLPE Insulation


ZC-YJV 1×300 mm² Power Cable
Frequently Asked Questions (FAQ)
Flame-Retardant Class C · XLPE Insulated · PVC Sheathed · Copper Conductor · 0.6/1 kV

Product Basics

Q1. What does the model “ZC-YJV” mean?
“Z” stands for flame-retardant, “C” denotes Class C flame-retardant performance, “YJ” means XLPE (cross-linked polyethylene) insulation, and “V” means PVC sheath. ZC-YJV is a copper-core, Class C flame-retardant, XLPE-insulated, PVC-sheathed low-voltage power cable.
Q2. What does “1×300 mm²” indicate?
“1” means a single-core cable. “300 mm²” is the nominal cross-sectional area of the copper conductor. This is a large cross-section cable typically used for main low-voltage bus connections, transformer secondary leads, and high-capacity distribution feeders in large industrial plants, commercial complexes, and infrastructure projects.
Q3. What is the rated voltage?
The rated voltage U₀/U is 0.6/1 kV (0.6 kV phase-to-earth, 1 kV phase-to-phase), designed for low-voltage power transmission and distribution systems.
Q4. What materials are used in construction?
Conductor: plain copper, Class 2 stranded (compact segmented conductor for large sizes). Insulation: cross-linked polyethylene (XLPE). Outer sheath: flame-retardant PVC. Standard ZC-YJV is unarmored. For direct burial or locations requiring mechanical protection, armored variants such as ZC-YJV22 (double steel tape) or ZC-YJV32 (fine steel wire) are recommended.

Technical Specifications

Q5. What is the maximum operating temperature?
The maximum continuous conductor temperature is 90 °C. During short-circuit events, the conductor may reach up to 250 °C for no more than 5 seconds. XLPE insulation provides excellent thermal stability and high current-carrying capacity for heavy-duty power distribution.
Q6. What is the typical current-carrying capacity?
For a 1×300 mm² copper XLPE cable, the ampacity is approximately 550–700 A when installed in free air at 30 °C ambient. Lower ratings apply when buried, installed in conduit, grouped with other cables, or at elevated ambient temperatures. For precise engineering design, consult the manufacturer's ampacity tables (GB/T 16895 / IEC 60364) and apply appropriate derating factors.
Q7. What is the conductor DC resistance?
The maximum DC resistance of a 300 mm² Class 2 copper conductor at 20 °C is approximately 0.0601 Φ/km (annealed copper), per GB/T 3956 / IEC 60228. The exact value should be verified against the factory test report for each production batch.

Installation & Applications

Q8. What is the minimum bending radius?
For single-core unarmored cables of this size, the minimum bending radius is 20 times the cable outer diameter (20D) during installation. Large cross-section cables are heavy and stiff, requiring dedicated pulling equipment, sufficient pulling tension control, and careful handling to avoid insulation and sheath damage. D = actual outer diameter.
Q9. What are the typical applications?
Common uses include: main low-voltage busbar connections in substations; transformer secondary leads to main switchgear; high-capacity feeders in large industrial plants and data centers; main incoming power for high-rise commercial complexes; and primary power distribution in infrastructure projects where Class C flame-retardant performance is required.
Q10. Which standards and certifications apply?
Manufactured in accordance with GB/T 12706 (equivalent to IEC 60502), with conductor compliance to GB/T 3956 / IEC 60228 and flame-retardant testing per GB/T 18380 / IEC 60332-3. Common certifications include CCC (China), CE (Europe), ISO 9001, RoHS, and VDE/TUV for specific international markets.