logo
Anhui Tongdu International Trade Co., Ltd.
Online Service

Online Service

Contact Person
+86 19056002718
WeChat QR Code
Follow Us

ZR-YJV Single Core Cable 1 X 300mm2 Flame Retardant 0.6/1kV Solid Copper XLPE Insulation

ZR-YJV Single Core Cable 1 X 300mm2 Flame Retardant 0.6/1kV Solid Copper XLPE Insulation

Basic Properties

country of origin
China
brand name
TD
certificate
CE/ISO/CCC
product model
ZR-YJV 1*300mm²

Trading Properties

moq
1 Meter
payment method
L/C,T/T
supply capacity
10000 meters per month

Product Summary

ZR-YJV 1*300mm² Flame Retardant Single Core Cable, 0.6/1kV Solid Copper, XLPE Insulation PVC Jacket for Construction Power Code Mean:ZR-Flame Retardant,YJ-XLPE Insulation,V-PVC Outer Sheathed ZR-YJV 1×300 mm² — Cable Profile 1. Identity. The ZR-YJV 1×300 is the 300 mm² class of the flame-retardant ...

Product Details

Highlight:

ZR-YJV Single Core Cable

,

Single Core Cable 1 x 300mm2

,

1kV Low Voltage Power Cable

Conductor​:
Bare Annealed Copper, Class 2 Stranded Circular, 61×∅2.52 Mm​ (typical), Conductor Ø ≈ 22.4 Mm
Conductor nominal area:
300 Mm²
Conductor construction:
Class 2, 61×∅2.52 Mm​ Min. 61 Wires Per GB/T 3956 (>240 Mm²)
Conductor diameter (approx.):
22.4mm
Insulation:
XLPE Compound, Extruded
Insulation thickness (nominal):
1.4 Mm​ (GB/T 12706.1, 300 Mm² Class)
Diameter over insulation (approx.):
25.2 Mm (22.4 + 2×1.4)
Filler / binder:
Flame-retardant (FR) Non-hygroscopic Tape / PP Mesh​ (single-core: Thin FR Binder, No Filler Body)
Outer sheath:
Flame-retardant PVC Compound (ZR Grade)​ — Contains Halogen, Not Low-smoke
Sheath thickness (nominal)​:
1.4 Mm​ (single-core; Some Makers Use 1.5 Mm For 300 Mm² — Verify Per Factory)
Overall cable diameter:
31.5 – 32.5 Mm​,PVC Density; Use 32.0 Mm For Design
Approx. weight:
2,350 – 2,500 Kg/km​,PVC Heavier Than PO; Use ≈ 2,420 Kg/km
Long-term service temperature:
90 °C
Short-circuit temperature (≤5 s):
250 °C
Emergency overload:
105–130 °C (limited Duration)
Routine test:
3.5 KV AC / 5 Min; Type Test 4.0 KV
Volume resistivity @90 °C:
≥ 10¹² Ω·cm

Product Description

ZR-YJV 1*300mm² Flame Retardant Single Core Cable, 0.6/1kV Solid Copper, XLPE Insulation PVC Jacket for Construction Power

 

Code Mean:ZR-Flame Retardant,YJ-XLPE Insulation,V-PVC Outer Sheathed

 

ZR-YJV 1×300 mm² — Cable Profile

1. Identity. The ZR-YJV 1×300 is the 300 mm² class of the flame-retardant YJV line: a single copper core under XLPE insulation and a PVC jacket, rated 0.6/1 kV (Um = 1.2 kV), 50 Hz. Certification path: GB/T 12706.1 / IEC 60502-1 (cable), GB/T 3956 / IEC 60228 (core), GB/T 19666 / GB/T 18380 (fire, default ZC).

 

2. Physical Build. Layer-by-layer nominal data:

 

Layer Build Wall Diameter
Core Annealed copper, Class 2, 61 × 2.5 mm (61/2.5, 1+6+12+18+24), 300 mm² — ≈ 18.7 mm (compacted; up to ≈ 19.2 mm)
Dielectric Cross-linked polyethylene 1.8 mm ≈ 22.3 mm over insulation
Jacket Flame-retarded PVC, ST2, black 2.5 mm ≈ 27.3 mm overall

Weight ≈ 3076 kg/km (2960–3076 across makers; copper alone ≈ 2667 kg/km); OD 27.3–28.4 mm.

ZR-YJV Single Core Cable 1 X 300mm2 Flame Retardant 0.6/1kV Solid Copper XLPE Insulation

3. Electrical Character. DC resistance ≤ 0.0601 Ω/km @ 20 °C; routine AC withstand 3.5 kV / 5 min; XLPE volume resistivity ≥ 1×10¹² Ω·cm; insulation resistance typically ≥ 36.7 MΩ·km; capacitance ≤ 0.45 μF/km. Reference ampacity ≈ 720 A in air (30 °C) and ≈ 630 A direct-buried — derate per GB/T 16895 / IEC 60364.

 

Parameter

Value

Note

Rated voltage U₀/U

0.6 / 1 kV

Uₘ = 1.2 kV

Test voltage AC (5 min)

3.5 kV​

Routine

Type-test voltage

4.0 kV

IEC 60502

DC resistance @20 °C (Class 2 Cu)​

≤ 0.0601 Ω/km​

GB/T 3956 / IEC 60228 max

AC resistance @90 °C (est.)

≈ 0.078 Ω/km

copper temp. coefficient

Current rating in air (30–40 °C, single circuit, single-core)

≈ 685 – 705 A​

PVC sheath; design ≈ 685 A​

Direct buried (20 °C, soil 1.0 K·m/W, 0.7 m)

≈ 620 – 640 A​

design ≈ 620 A​

Short-circuit current (1 s adiabatic, Cu, 250 °C)

≈ 34.68 kA

reference

Frequency

50/60 Hz AC (DC usable)

—

 

4. Thermal Boundaries. Continuous 90 °C; short-circuit 250 °C (≤ 5 s); ambient −20 to +45 °C; laying ≥ 0 °C; minimum bend radius 20 × OD (single core).

 

ZR-YJV 1×300 mm² Flame-Retardant Copper-Conductor XLPE-Insulated PVC-Sheathed Power Cable — Product Parameters (0.6/1 kV)
Construction: CU / XLPE / PVC  •  Standards: GB/T 12706.1, IEC 60502-1 (cable), GB/T 3956 (conductor), GB/T 19666 & GB/T 18380 (flame retardance)  •  Nominal values for reference — confirm against factory test certificate
No. Category Parameter Value Unit Notes / Standard Reference
A. Product Identification
1 Identification Product name Flame-retardant copper-conductor XLPE-insulated PVC-sheathed power cable — Designation ZR-YJV; "ZR" = flame-retardant (halogen-containing)
2 Identification Model designation ZR-YJV 1×300 — Cu / XLPE / PVC
3 Identification Design standards GB/T 12706.1; IEC 60502-1 — Conductor: GB/T 3956 / IEC 60228; flame retardance: GB/T 19666, GB/T 18380; safety: CCC / production licence
4 Identification Rated voltage U0/U 0.6/1 kV Max system voltage Um = 1.2 kV
5 Identification Rated frequency 50 Hz AC power distribution
6 Identification Number of cores 1 — Single-core cable
7 Identification Nominal cross-sectional area 300 mm² Nominal conductor cross-section per GB/T 3956
B. Cable Construction (from conductor to outer sheath)
8 Conductor Material Plain annealed copper (Cu) — High-conductivity electrolytic / oxygen-free copper
9 Conductor Conductor class Class 1 or Class 2 (typical: Class 2, stranded) — GB/T 3956 / IEC 60228
10 Conductor Typical stranding construction 61 wires × 2.5 mm (61/2.5, lay-up 1+6+12+18+24) — Class 2 round stranded; nominal section ≈ 300 mm²
11 Conductor Conductor diameter ≈ 18.7 mm ≈ 18.7 mm compact (18.7–19.2 mm across stranding practice)
12 Conductor Max. DC resistance of conductor at 20 °C 0.0601 Ω/km GB/T 3956, Class 2 copper; acceptance criterion for 300 mm²
13 Insulation Material Cross-linked polyethylene (XLPE) — Thermally cross-linked; natural/transparent colour
14 Insulation Nominal insulation thickness 1.8 mm GB/T 12706.1 / IEC 60502-1 (0.6/1 kV, 300 mm²)
15 Insulation Diameter over insulation ≈ 22.3 mm ≈ 18.7 + 2 × 1.8 (calculated, compact conductor)
16 Sheath Material Flame-retardant polyvinyl chloride (PVC, ST2 type) — Colour: black (or as ordered)
17 Sheath Nominal sheath thickness 2.5 mm GB/T 12706.1 / IEC 60502-1 (cabhr table; ahtk lists 1.9)
18 Dimensions Approx. overall diameter 27.3 mm ≈ 27.3 mm (27.3–28.4 mm across sources: cabhr 27.3; ahtk 28.4; Meihe 28.24)
19 Dimensions Approx. cable weight ≈ 3076 kg/km cabhr 3076; ahtk 3056; Meihe 2960 (copper core alone ≈ 2667 kg/km)
C. Electrical Performance
20 Electrical Max. DC conductor resistance at 20 °C 0.0601 Ω/km GB/T 3956; routine measurement
21 Electrical Power-frequency withstand voltage (routine test) 3.5 kV / 5 min, no breakdown — AC 50 Hz; per GB/T 12706.1 / IEC 60502-1
22 Electrical Insulation resistance (finished cable, 20 °C) ≥ 36.7 MΩ·km Typical finished-cable reference for 0.6/1 kV XLPE cables; varies with geometry and manufacturer test method
23 Electrical XLPE volume resistivity at 20 °C ≥ 1 × 10¹² Ω·cm Material-level requirement (manufacturer reference)
24 Electrical Capacitance (single-core, approx.) ≤ 0.45 μF/km Manufacturer reference value
25 Electrical Reference ampacity — in air, 30 °C, single core ≈ 720 A cabhr table (720 A); depends on laying, grouping, ambient — apply correction factors per GB/T 16895 / IEC 60364
26 Electrical Reference ampacity — direct burial, 25 °C ≈ 630 A cabhr table; depends on soil thermal resistivity and depth
D. Thermal Performance
27 Thermal Max. continuous conductor temperature 90 °C XLPE insulation temperature class
28 Thermal Max. conductor temperature under short-circuit (≤ 5 s) 250 °C Per GB/T 12706.1 / IEC 60502-1
29 Thermal Ambient service temperature range -20 to +45 °C Per Qifan datasheet family; check project specification
30 Thermal Min. installation (laying) temperature 0 °C Pre-heat the cable if ambient is below 0 °C
E. Flame Retardance (ZR)
31 Flame retardance Flame-retardant class ZC (class C) by default for "ZR" — GB/T 19666; ZA / ZB available on request; halogen-containing PVC (not LSZH)
32 Flame retardance Single-cable vertical flame-spread test Pass — GB/T 18380.12
33 Flame retardance Bunched flame-spread test (class C) Char extent ≤ 2.5 m above burner bottom edge — GB/T 18380.35: non-metallic volume ≥ 1.5 L/m; flame application 20 min
34 Flame retardance Halogen content Halogen-containing (PVC) — For low-smoke, zero-halogen requirement select WDZ-YJY (LSZH) type
F. Installation
35 Installation Min. bending radius — single-core cable 20 × OD — Qifan & Huaneng datasheets; OD = actual cable diameter
36 Installation Laying methods Conduit, tray, cable trench, tunnel, duct, supported/suspended aerial — Also direct burial with mechanical protection where permitted
37 Installation Site withstand test after installation DC 4U0 = 2.4 kV, 15 min (recommended) — Per utility procurement standard Q/GDW 13244.1-2018; practice may vary by project
G. Packing & Delivery
38 Packing Standard delivery length 100 m per coil/drum (or as ordered) — Typical industry practice; custom lengths available
39 Packing Cable marking Model, rated voltage, manufacturer, year of manufacture, sequential length marks — Per GB/T 6995 / project specification
40 Packing Packing form Wooden drum / coil / export packing — As per customer requirement

 

5. Flame Resistance. Passes GB/T 18380.12 single burn and class-C bunched burn GB/T 18380.35 (char ≤ 2.5 m) → ZC per GB/T 19666. PVC carries halogen — choose WDZ-YJY for LSZH specs.

 

Flame Retardant Performance Data Sheet — ZR-YJV 0.6/1 kV 1×300 mm²
ZR = Legacy flame-retardant mark; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC)
1. GENERAL INFORMATION
1 Cable designation ZR-YJV 1×300 mm² Cu / XLPE / PVC (FR) GB/T 12706.1
2 Rated voltage U₀/U 0.6 / 1 kV Uₘ = 1.2 kV IEC 60502-1
3 Flame retardant class Class C (default for ZR) Bundled combustion, char ≤ 2.5 m GB/T 19666-2019
4 Conductor Cu, Class 2, 61×∅2.52 mm Ø ≈ 22.4 mm GB/T 3956
5 Insulation / Sheath XLPE 1.4 mm / PVC (FR) 1.4 mm Black GB/T 12706.1
2. FLAME RETARDANT CLASSIFICATION (ZR = Class C)
Level Designation example Non-metallic volume (L/m) Flame application Char length (max)
A  ZA-YJV / WDZA ≥ 7.0 40 min ≤ 2.0 m
B ZB-YJV / WDZB 3.5 40 min ≤ 2.5 m
C  ZC-YJV / ZR-YJV 1.5 20 min ≤ 2.5 m
D  ZD-YJV 0.5 20 min ≤ 2.5 m
3. FLAME RETARDANT TEST ITEMS & TECHNICAL LIMITS (this product = Class C)
No. Test item Standard / Method Requirement / Limit (Class C) Result
1 Bunched flame propagation (vertical) GB/T 18380.3 / IEC 60332-3-24 (Cat. C) Char length ≤ 2.5 m above top of burner; self-extinguishing within 1 h Pass
2 Single-cable flame (vertical) GB/T 18380.1 / IEC 60332-1-2 No sustained burning after removal of flame; char ≤ 50 mm × 50 mm Pass
3 Non-metallic material volume (test specimen) GB/T 18380.3 (Cat. C) 1.5 L/m of cable length 1.5 L/m
4 Flame source duration (Cat. C) GB/T 18380.3 20 min (supply air 5000 L/min, propane 600 mm³/h) 20 min
5 pH value of combustion gases GB/T 17650.2 / IEC 60754-2 ≥ 4.3 (informative for ZR; certified for WDZ) ≥ 4.3*
6 Conductivity of acid gases GB/T 17650.2 / IEC 60754-2 ≤ 10 µS/mm (informative for ZR; certified for WDZ) ≤ 10*
7 Halogen acid gas emission (HCI) GB/T 17650.1 / IEC 60754-1 ≤ 5 % (informative for ZR; PVC sheath contains Cl) Contains Cl*
8 Smoke density (transmittance, min.) GB/T 17651 / IEC 61034-2 ≥ 60 % (informative for ZR; certified for WDZ) Not certified*
9 Oxygen index (LOI, min.) GB/T 2406 / IEC 60754 ref. ≥ 30 % (typical for FR-PVC ≥ 32 %) ≥ 32 %
10 Flame retardant in insulation & sheath FR-PVC + FR-XLPE compound Sb₂O₃ / Al(OH)₃ based FR system Compliant
4. NOTES
* Items 5–8 marked with * are INFORMATIVE for plain ZR (Class C) cable. ZR-YJV uses flame-retardant PVC which contains halogen; pH / conductivity / smoke / halogen are NOT certified limits.
** For certified halogen-free + low-smoke performance, use WDZ-YJY. For circuit-integrity (fire-survival), use NH-ZR-YJV.
*** ZR is a legacy GB prefix; modern specifications use ZC (Class C). ZR-YJV ≈ ZC-YJV in flame-retardant performance.

 

Flame Retardant Class Comparison — ZR (Class C) vs WDZ vs Z (A/B)
Property ZR-YJV (this, C) WDZ-YJV WDZA-YJY (A) NH-ZR-YJV Ordinary YJV
Flame retardant Class C Class C Class A (最高) Class C None
Halogen-free (W) No (PVC含Cl) Yes Yes No (Include Mica Tape) No
Low smoke (D) No Yes (≥60%) Yes (≥60%) Yes No
Fire-survival (NH) No No No Yes (90 min, 830℃) No
Smoke corrosivity Corrosive HCI Non-corrosive Non-corrosive Low corrosivity Corrosive
Typical use General, cost-saving Metro/Hospital Tunnel/Underground Emergency circuits General
Relative price 1.0 (base) ~1.15× ~1.30× ~1.40× 1.0 (base)

 

6. Test Regime. Routine: DC resistance, 3.5 kV/5 min, dimensional audit (ins. ≥ 1.8 mm, sheath ≥ 2.5 mm). Sample: XLPE hot-set (200 ± 3 °C / 15 min / 0.2 MPa). Type: flame + bending. Site: DC 4U0 = 2.4 kV / 15 min (Q/GDW 13244.1-2018 practice).

 

ZR-YJV 1×300 mm² — Test / Verification Parameters (per GB/T 12706.1 & IEC 60502-1)
Test Stage Test Item Method / Standard Requirement / Acceptance Criterion Notes
Routine test Conductor DC resistance measurement GB/T 3956 (IEC 60228) ≤ 0.0601 Ω/km at 20 °C Measured on every production length
Routine test Power-frequency withstand voltage GB/T 12706.1 / IEC 60502-1 3.5 kV AC, 5 min, no breakdown Applied between conductor and water/earth; 50 Hz
Routine test Construction check — insulation & sheath thickness, outer diameter GB/T 2951 Within GB/T 12706.1 tolerances Insulation ≥ 1.8 mm nominal; sheath ≥ 2.5 mm nominal
Sample test Hot set (thermal elongation) test — XLPE insulation GB/T 12706.1 §16.3.13 / GB/T 2951.11 200 ± 3 °C, 15 min, stress 0.2 MPa: elongation under load ≤ 175 %; permanent elongation after cooling ≤ 15 % Verifies degree of cross-linking
Sample test Conductor construction & diameter check GB/T 3956 Class 2; 61 × 2.5 mm; Ø ≈ 18.7 mm Sampled per batch
Type test Single-cable vertical flame-spread test (flame retardance) GB/T 18380.12 No flame spread; charring does not reach top reference point ZR / ZC flame-retardant property
Type test Bunched flame-spread test, class C GB/T 18380.35 Char extent ≤ 2.5 m above burner bottom edge; flame application 20 min; non-metallic volume ≥ 1.5 L/m Class ZC per GB/T 19666
Type test Bending test (mechanical) GB/T 12706.1 Bend around specified mandrel without insulation/sheath damage Mandrel diameter related to cable OD
Post-installation DC withstand test after installation Q/GDW 13244.1-2018 (recommended practice) 4U0 = 2.4 kV DC, 15 min, no breakdown For new installations; verify project specification
Optional Insulation resistance measurement at 20 °C Manufacturer test method ≥ 36.7 MΩ·km (typical finished-cable value) Not a routine item in GB/T 12706.1; confirm with factory
Optional XLPE volume resistivity at 20 °C Manufacturer / material test ≥ 1 × 10¹² Ω·cm Material-level reference

 

7. Installation Do's & Don'ts. Do keep bends ≥ 20 × OD, use rollers and smooth radii, protect from UV; don't drag over sharp metal, flex continuously, or energise before the site DC test. Verify the actual core Ø before connector selection.

 

Size

Insulation

Sheath

OD (mm)

Weight (kg/km)

R₂₀ (Ω/km)

Ampacity (A) air / buried

1×16

0.7

1.4

9.4

~215

≤1.15

105 / 95

1×25

0.9

1.4

11.2

~310

≤0.727

140 / 130

1×35

0.9

1.4

13.2

~410

≤0.524

175 / 160

1×50

1.0

1.4

15.6

~545

≤0.387

210 / 190

1×70

1.1

1.4

17.8

~720

≤0.268

270 / 245

1×95

1.1

1.4

20.0

~950

≤0.193

330 / 300

1×120

1.1

1.4

22.0

~1,140

≤0.153

385 / 350

1×150

1.2

1.4

24.0

~1,360

≤0.124

440 / 400

1×185

1.2

1.4

26.0

~1,600

≤0.0991

505 / 460

1×240

1.2

1.4

29.0

~1,980

≤0.0754

590 / 535

1×300​

1.4​

1.4​

32.0​

~2,420​

≤0.0601​

685 / 620

 

8.Cross Section Structure

 

ZR-YJV Single Core Cable 1 X 300mm2 Flame Retardant 0.6/1kV Solid Copper XLPE Insulation

 

ZR-YJV 1×300 mm² — Cable Cross-Section Structure (Schematic)
Layers from conductor to outer sheath · nominal values per GB/T 12706.1 / IEC 60502-1 · not to exact scale
           
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductor (Cu) Annealed copper, Class 2 stranded — 61 × 2.5 mm (61/2.5, 1+6+12+18+24), nominal 300 mm² — ≈ 18.7 (Ø) Current-carrying element; max DC resistance ≤ 0.0601 Ω/km @ 20 °C
2 Insulation (XLPE) Cross-linked polyethylene 1.8 ≈ 22.3 (Ø over insulation) Dielectric barrier; rated 90 °C continuous; withstands 3.5 kV / 5 min
3 Outer sheath (PVC) Flame-retardant PVC, ST2 type, black 2.5 ≈ 27.3 (Ø overall) Mechanical & moisture protection; flame retardance ZC (ZR) per GB/T 19666
Key Dimensions & Properties
Overall diameter 27.3 mm 27.3–28.4 mm across sources (cabhr 27.3; ahtk 28.4; Meihe 28.24)    
Approx. cable weight ≈ 3076 kg/km cabhr 3076; ahtk 3056; Meihe 2960; Cu core alone ≈ 2667 kg/km    
Rated voltage 0.6/1 kV AC 50 Hz; max system voltage Um = 1.2 kV    
Max conductor temperature 90 / 250 °C Continuous / short-circuit (≤ 5 s)    
Min. bending radius (single-core) 20 × OD — OD = actual cable diameter    
Flame-retardant class ZC (ZR) — GB/T 19666    

 

Product Structure Introduction — ZR-YJV 1×300 mm² (English)
Layered construction description, from conductor to outer sheath · per GB/T 12706.1 & IEC 60502-1 · CU / XLPE / PVC · 0.6/1 kV
 
1. Product Perspective
The ZR-YJV 1×300 is the next step up in the flame-retardant YJV range, engineered for 0.6/1 kV AC duty with a 300 mm² copper path. It observes GB/T 12706.1 / IEC 60502-1 for the finished cable, GB/T 3956 / IEC 60228 for the core and GB/T 19666 for the ZR (default ZC) rating. Externally it measures about 27.3 mm and masses ≈ 3076 kg/km; coils and drums are supplied in 100 m standard lengths.
As a fixed-installation cable it is not meant for trailing or continuous flexing; mechanical planning should assume rigid handling.
 
2. The Conductor Layer
Sixty-one copper wires, each 2.5 mm in diameter (61/2.5, concentric order 1+6+12+18+24), are stranded to Class 2 for a nominal 300 mm². The finer multi-wire arrangement improves bending response and eases pulling through risers, while DC resistance at 20 °C is bounded at 0.0601 Ω/km. Compacted, the core measures ≈ 18.7 mm; a relaxed round-lay construction can reach ≈ 19.2 mm.
 
3. The Insulation Layer
XLPE is extruded over the core at 1.8 mm, moving the diameter over insulation to ≈ 22.3 mm. Thermoset behaviour after cross-linking allows 90 °C continuous service and 250 °C for five seconds under short-circuit. The dielectric also delivers volume resistivity ≥ 1×10¹² Ω·cm and survives the mandatory 3.5 kV AC, 5-minute routine test on every production run.
 
4. The Sheath Layer
A heavier 2.5 mm flame-retardant PVC (ST2) jacket closes the cable at ≈ 27.3 mm. The thicker wall reflects the larger diameter and adds abrasion and impact margin, and it is the layer that earns the ZC fire rating via GB/T 18380.12 (single burn) and GB/T 18380.35 (class C, char ≤ 2.5 m). Halogen is inherent to PVC; WDZ-YJY is the zero-halogen substitute where smoke and toxicity limits apply.
 
5. Handling & Application Notes
• Respect the 20 × OD minimum bend for single cores.  • Run the DC 4U0 = 2.4 kV / 15 min site test before energising.  • Keep service ambient within −20 to +45 °C; warm drums when below 0 °C.  • Recalculate ampacity for grouping, tray fill and soil conditions.  • Verify the actual core diameter against the certificate before selecting connectors.

 

9. Field of Use. Transformer LV tails, large motor and pump feeders, switchgear risers, industrial sub-mains, data-centre and plant distribution at 0.6/1 kV — trays, ducts, trenches, tunnels; indoor or sheltered outdoor.

 

ZR-YJV Single Core Cable 1 X 300mm2 Flame Retardant 0.6/1kV Solid Copper XLPE Insulation

 

10. Purchase Notes. Order as ZR-YJV 0.6/1 kV 1×300, with length, drum type and marking. Standard 100 m drums; confirm all figures against the factory certificate.

 

ZR-YJV Single Core Cable 1 X 300mm2 Flame Retardant 0.6/1kV Solid Copper XLPE Insulation

 

ZR-YJV Single Core Cable 1 X 300mm2 Flame Retardant 0.6/1kV Solid Copper XLPE Insulation