"bs 5467 single core electrical cable"
Please try a different search term or browse our product categories.
RVVP 5x2.5mm² Multi-core Shielded Cable Heavy Load Flexible Copper Control Wire for Industrial Equipment
RVVP 5x2.5mm² Multi-core Shielded Cable Heavy Load Flexible Copper Control Wire for Industrial Equipment Cable Designation & Meaning Code Meaning R Flexible cord V PVC insulation V PVC sheath P Copper braid shield 5×2.5 mm² Five cores of 2.5 mm² copper conductor Construction : Five 1.5 mm² fine...
Heavy Duty 4+1 Core Cable ZR-YJV 4x120mm²+1x70mm² XLPE Copper Flame Retardant
Heavy Duty 4+1 Core Cable ZR-YJV 4x120mm²+1x70mm² XLPE Copper Flame Retardant Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×120 mm² + 1×70 mm² Four cores of 120 mm² (3 phase + 1 neutral) + one ...
High Rise Building Main Cable ZR-YJV 4x95mm²+1x50mm² XLPE Copper Flame Retardant
High Rise Building Main Cable ZR-YJV 4x95mm²+1x50mm² XLPE Copper Flame Retardant Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×95 mm² + 1×50 mm² Four cores of 95 mm² (3 phase + 1 neutral) + one ...
5x16mm2 5 Cores Cable Copper Xlpe Insulated Armoured For Building MEP Works
5*16mm² Flame Retardant Power Cable ZR-YJV Copper Conductor for Building MEP Works Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 5×16 mm² Five equal cores of 16 mm² copper conductor Construction : ...
Shopping Mall Main Power Cable ZR-YJV 4x150mm²+1x70mm² XLPE Copper Flame Retardant
Shopping Mall Main Power Cable ZR-YJV 4x150mm²+1x70mm² XLPE Copper Flame Retardant Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×150 mm² + 1×70 mm² Four cores of 150 mm² (3 phase + 1 neutral) + ...
RVVP 2x0.75mm² Shielded Signal Cable Braided Copper Low Noise Communication Wire 300/500V
RVVP 2x0.75mm² Shielded Signal Cable Braided Copper Low Noise Communication Wire 300/500V Cable Designation & Meaning Code Meaning R Flexible conductor (Class 5 fine-stranded) V PVC insulation V PVC sheath P Copper wire shield (braid or braid+aluminium foil) 2×0.75 mm² Two cores, each 0.75 mm² ...
ZR-YJV 1*185mm² Flame Retardant Copper Cable,0.6/1kV XLPE Insulation PVC Sheath for Building Wiring
ZR-YJV 1*185mm² Flame Retardant Copper Cable,0.6/1kV XLPE Insulation PVC Sheath for Building Wiring Code Mean:ZR-Flame Retardant,YJ-XLPE Insulation,V-PVC Outer Sheathed. ZR-YJV 1×185 mm² — Specification Sheet 1. General Description. The ZR-YJV 1×185 is a single-core, flame-retardant cable of CU/XLPE...
2X1.5mm2 Flat Sheathed Wires PVC ST4 Copper Electrical Wire
300/500V White BVVB-2*1.5mm² Twin Solid Copper Core Electrical Wire PVC Insulation Household Wire BVVB 2×1.5 mm² Copper Core PVC Insulated PVC Sheathed Flat Cable Model decode (GB/T 5023 / JB/T 8734 / IEC 60227): B = Building wire (fixed wiring) · V = PVC insulation · V = PVC sheath · B = Flat ...