"bs 5467 single core electrical cable pvc"
Please try a different search term or browse our product categories.
4.0mm2 Solid Copper Conductor 450V 750V Single Stranded Copper Wire
BV 4.0mm² Solid Copper PVC Insulated Building Wire 450/750V Easy Pull Electrical Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 4.0 mm² Nominal cross-sectional area of conductor Construction: Plain copper conductor ...
Yellow PVC Copper Single Core Switch Wire 450v 750V Lighting Control Cable
Yellow BV 2.5mm² PVC Copper Single Core Switch Wire 450/750V Lighting Control Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain copper conductor ...
H1Z2Z2-K 4.0mm2 Photovoltaic Solar Cable TUV 1500V XLPE Copper Cable
H1Z2Z2-K 4.0mm² TUV 1500V DC Solar Cable UV Resistant Halogen Free XLPE Copper Cable Designation & Meaning Code Meaning H Harmonized cable (H) 1 Rated voltage 1 kV AC (U₀/U = 1/1 kV reference) Z Halogen-free compound (Z = halogen-free) 2 Insulation layer — cross-linked halogen-free compound (XLPO) Z ...
1500V Solar Pv Cable Halogen Free Class 5 Flexible PV Photovoltaic Wire
H1Z2Z2-K 6.0mm² TUV 1500V DC Solar Main Cable UV Resistant PV Photovoltaic Wire Cable Designation & Meaning Code Meaning H Harmonized cable (H) 1 Rated voltage 1 kV AC (U₀/U = 1/1 kV reference) Z Halogen-free compound (Z = halogen-free) 2 Insulation layer — cross-linked halogen-free compound (XLPO) ...
UV Resistant Solar Panel Pv Cable PV1-F XLPO Solar Array Cable
Solar Array Cable PV1-F 6.0mm² TUV 1500V DC UV Resistant PV String Wire Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 6.0 mm² Nominal cross-sectional area of conductor Construction: Tinned copper conductor, ...
YJV22 Medium Voltage Power Cable 3x150mm2 Copper Mv Armoured Cable 15kV
YJV22 3x150mm² Copper XLPE Armored MV Cable 8.7/15kV Reliable Underground Power Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath 22 Steel tape armoured (double steel tape) 3×150 mm² Three cores, each 150 mm² copper Construction: Copper ...
3x120mm2 Medium Voltage Power Cable 8.7kV 15kV Aluminum Mc Cable
Industrial Main Aluminum Cable YJLV22 3x120mm² 8.7/15kV Armored MV Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated ...
BTTRZ Flame Retardant Cable 4x150mm2+1x120mm2 Mineral Insulated Cable
Ultra Fire Cable BTTRZ 4x150mm²+1x120mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...