1 X 70mm2 Single Core Cable Solid Copper XLPE Insulation PVC Jacket For Building Power

1 X 70mm2 Single Core Cable Solid Copper XLPE Insulation PVC Jacket For Building Power

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
ZR-YJV 1*70mm²

Trading Properties

moq
100 meters
payment method
L/C,T/T
supply capacity
100000 meters per month

Product Summary

ZR-YJV 1*70mm² Single Conductor , 0.6/1kV Solid Copper, XLPE Insulation PVC Jacket for Building Power Cable Designation & Meaning Code Meaning ZC Flame retardant C— IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 1×70 mm² Single core, 70 mm² copper conductor ...

Product Details

Highlight:

1 x 70mm2 Single Core Cable

,

Single Core Cable non hygroscopic

,

Building Powerpvc jacket cable

Conductor:
Bare Annealed Copper, Class 2 Stranded Circular, 19×∅2.22 Mm​ (typical), Conductor Ø ≈ 11.0 Mm
Conductor nominal area:
70 Mm²
Conductor construction:
Class 2, 19×∅2.22 Mm​ Min. 19 Wires Per GB/T 3956 (>35 Mm²)
Conductor diameter (approx.):
11.0 Mm
Insulation:
XLPE Compound, Extruded
Insulation thickness:
1.1 Mm​ (GB/T 12706.1, 70 Mm² Class)
Diameter over insulation (approx.):
13.2 Mm(11.0 + 2×1.1)
Filler / binder:
Flame-retardant (FR) Non-hygroscopic Tape / PP Mesh
Outer sheath:
Flame-retardant PVC Compound (ZR Grade)​
Sheath thickness:
1.4 Mm​ (single-core; Some Makers Use 1.5 Mm For 70 Mm² — Verify Per Factory)
Overall cable diameter:
17.3 – 18.5 Mm​ PVC Density; Use 17.8 Mm For Design
Approx. weight:
700 – 750 Kg/km
Long-term service temperature:
90 °C
Short-circuit temperature (≤5 s):
250 °C
Emergency overload:
105–130 °C (limited Duration)
Routine test:
3.5 KV AC / 5 Min; Type Test 4.0 KV
Volume resistivity @90 °C:
≥ 10¹² Ω·cm

Product Description

ZR-YJV 1*70mm² Single Conductor , 0.6/1kV Solid Copper, XLPE Insulation PVC Jacket for Building Power


Cable Designation & Meaning

Code

Meaning

ZC

Flame retardant C— IEC 60332-3-24, Category C

YJ

Cross-linked polyethylene (XLPE) insulation

V

PVC sheath

1×70 mm²

Single core, 70 mm² copper conductor


Construction: Single Class 2 stranded copper conductor, XLPE insulation, PVC outer sheath (no armour, no shield).

1 X 70mm2 Single Core Cable Solid Copper XLPE Insulation PVC Jacket For Building Power

ZC-YJV 1×70 mm² — LV Flame-Retardant Power Cable — Specification

1. Overview & Ratings. ZC-YJV 1×70 is a single-core LV power cable rated 0.6/1 kV (Um 1.2), 90 °C working, with a ZC class C flame-retardant PVC sheath. One compacted 70 mm² copper core, XLPE insulation, unscreened. OD ≈ 16.5 mm, ≈ 870 kg/km, ≈ 195 A (air, 30 °C) — a sub-main, branch-power and motor-short-lead cable; ZC self-extinguishes but is not a 950°C fire-rated circuit.


2. Construction Stack (Inner → Outer).

Layer Build Function
Conductor 1×70 compacted Cu, Class 2, ≈19 strands Power core
XLPE insulation Cross-linked PE, ≈1.4 mm 90 °C dielectric
PVC ZC sheath Flame-retardant class C, ≈1.7 mm Protection, self-extinguish


3. Electrical Characteristics. Core R ≤ 0.268 Ω/km @20 °C. Test 3.5 kV AC / 5 min; nominal ≈ 195 A (air, 30 °C); short-circuit ≈ 6.2 kA / 1 s; 50/60 Hz; unscreened; insulation resistance high and stable.

Insulation & Sheath Data

Property

Value

Insulation material

XLPE (cross-linked polyethylene)

Outer sheath material

PVC (ST₂)

Long-term service temp.

90 °C (continuous)

Max. conductor temp. (normal)

90 °C

Short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Test voltage AC (5 min)

3.5 kV

Dielectric strength

≥ 20 kV/mm

Volume resistivity @20 °C

≥ 1×10¹⁴ Ω·cm

Shield

None as standard (can be added)


Electrical Parameters

Parameter

Value

Note

Rated voltage U₀/U

0.6 / 1 kV

GB/T 12706.1 / IEC 60502-1

Max. system voltage

1.2 kV AC

—

Test voltage AC (5 min)

3.5 kV

Routine test

DC resistance @20 °C

≤ 0.268 Ω/km

GB/T 3956 Class 2 Cu max

AC resistance @90 °C (est.)

≈ 0.344 Ω/km

—

Current rating in air (30 °C)

Phase: 230 A​

single-core, touching, in free air

Current rating in tray (30 °C)

Phase: 255 A​

single-core, spaced 2×OD

Current rating buried in ground (20 °C, thermal resistivity 1.2 K·m/W)

Phase: 240 A​

direct buried

Current rating in conduit (30 °C)

Phase: 205 A​

—

Short-circuit current (1 s, Cu, 250 °C)

≈ 7.7 kA (7,700 A)

—

Capacitance (core-to-sheath, approx.)

≈ 0.18 µF/km

XLPE

Inductive reactance (approx.)

≈ 0.08 Ω/km

at 50 Hz

Frequency

50/60 Hz AC

—


Reference values: 1×70 at 230 A, single-phase 230 V → max load ≈ 53 kW​ (cos φ = 0.8). Suitable for power distribution, transformer connections, and panel feeders.


4. Thermal & Flame. 90 °C continuous, 250 °C short-time; ZC class C self-extinguishing on removal of flame — flame retardancy, not 950°C circuit-integrity; ambient 0~+40 °C indoor/tray; use UV grade if exposed.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

90 °C (continuous)

Max. short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Min. installation ambient temp.

0 °C (below 0 °C requires preheating)

Service ambient range

−20 °C to +90 °C

Flexing temp. range

0 °C to +90 °C

Fire Performance (ZC-YJV — Flame Retardant C)

Property

Value / Requirement

Flame retardant

GB/T 18380.12 / IEC 60332-1-2​ (single cable, self-extinguishing)

Flame retardant class

Class C​ (ZC) per GB/T 19666

Halogen content

Contains halogen (PVC sheath)

Smoke density

Not low-smoke (PVC)

Corrosivity

Corrosive (PVC)

Toxicity

Toxic fumes when burned (PVC)

EMI shielding

None (no metallic screen/armour)


5. Installation Practice & Handling. Standard Cu lugs and glands; bend ≥ 15×OD ≈ 248 mm; derate when bundled in parallel; indoor/tray/conduit/riser; continuity and insulation after laying; cold bending not below 0 °C.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 15 × OD → ≈ 248 mm at Ø16.5 mm

single-core unarmoured

Max. pulling tension

1,050 N (70 mm² × 15 N/mm²)

Cu conductor limit

Direct burial

Suitable (with sand bedding)

—

Surface mounting

Excellent (cable tray, ladder, cleats)

—

Conduit ID

≥ 25 mm

—

Fixing

cable ties, cleats

—

Impact resistance

Moderate

—

Water resistance

Good (PVC sheath)

—

UV resistance

Fair (PVC degrades outdoors, use UV-resistant PVC or conduit)

—

Flex life

Good (Class 2 stranded)

fixed installation

Termination note

Standard compression lugs or mechanical connectors

—


6. Typical Service Applications. Sub-main feeders, branch power, motor short leads, panel feeders, lighting trunk, general LV distribution inside buildings.

1 X 70mm2 Single Core Cable Solid Copper XLPE Insulation PVC Jacket For Building Power


7. Testing & QA Regime (14 items). Routine: DC resistance, 3.5 kV withstand, insulation resistance, continuity, sheath/insulation thickness, dimensional check, conductor construction, insulation eccentricity, sheath appearance, printing legibility, mass per unit length. Type: ZC class C flame test, short-circuit rating.


Cable Parameters


ZC-YJV 1×70 mm² — LV Flame-Retardant Power Cable — Full Parameter Sheet 
Cu conductor / XLPE insulation / PVC sheath · ZC flame-retardant class C · 0.6/1 kV · ≈ 16.5 mm · single-core feeder, sub-main & branch power
Parameter Value Unit Remarks / Standard
01 · Identification
Cable type ZC-YJV — Cu / XLPE / PVC, flame-retardant class C — LV power
Rated voltage (U0/U) 0.6/1 kV Low voltage
Maximum operating voltage (Um) 1.2 kV Phase-to-earth
Core configuration 1×70 — Single core
Conductor material Compacted stranded annealed copper — Class 2
Insulation XLPE cross-linked polyethylene — 90°C
Sheath PVC, flame-retardant class C (ZC) — Slate indigo
Flame retardancy ZC class C (self-extinguishing, not fire-rated) — Flame retardant
Suitable for Fixed indoor wiring, tray, conduit, riser — Power
Application Sub-main feeder, branch power, motor short lead — General
02 · Conductors
Power core 1 × 70 mm² Single
Conductor type Compacted stranded Cu, Class 2 — Round
DC resistance (70) @ 20°C ≤ 0.268 Ω/km Cu 70
Stranding Layer-compacted, concentric — Stable OD
Strands (nom., est.) ≈ 19 compacted — Class 2
Surface Bare copper, tinned optional — Contact
03 · Insulation
Insulation material XLPE (cross-linked PE) — 90°C rated
Insulation thickness (nom.) ≈ 1.4 mm Single-core
Working conductor temp. 90 °C Normal
Short-circuit temp. 250 °C Max, short time
Insulation resistance High and stable MΩ·km XLPE
Color Natural / phase color on request — Identification
04 · Sheath & Flame Retardancy
Sheath material PVC, flame-retardant ZC — Class C
Sheath thickness (nom.) ≈ 1.7 mm Overall
Finished outer diameter ≈ 16.5 mm Single core
Flame behavior Self-extinguishing, class C — Not 950°C fire-rated
Sheath color Slate indigo (other on request) — Marking
05 · Electrical
Rated voltage (U0/U) 0.6/1 kV LV
Max voltage (Um) 1.2 kV Phase-to-earth
Nominal current (70 core) ≈ 195 A Air, 30°C
Test voltage (AC) 3.5 kV / 5 min — Routine
Insulation resistance High, XLPE MΩ·km Stable
Short-circuit current (70, 1s) ≈ 6.2 kA Copper
Frequency 50 / 60 Hz General
06 · Thermal & Environment
Normal conductor temp. 90 °C Continuous
Installed ambient 0 ~ +40 °C Indoor/tray
Min install temp. 0 °C Cold bending
Burning Self-extinguishing, ZC class C — Flame retardant
Outdoor / UV Indoor preferred; use UV grade if exposed — PVC limit
Oil / chemicals Resistant to common oils; check aggressive media — General
07 · Mechanical & Construction
Min bending radius (fixed) ≥ 15 × OD ≈ 248 mm Single-core
Flexibility Flexible stranded, single-core — Easy pull
Shielding None (unscreened power) — General
Cable weight per km ≈ 870 kg/km Copper core
Circularity Compacted round, stable OD — Conduit fit
08 · Factory Advantages
Compacted round core Press-lay keeps OD tight for clean conduit fit and smooth pull — Easy route
Controlled XLPE cure Even cross-linking line, stable 90°C dielectric lot to lot — Consistent insulation
Dosed ZC compound Flame-retardant PVC dosed to class C self-extinguish — Safety margin
Length-on-demand Cut to exact meter, sealed ends, minimal offcut — No waste
Batch resistance log Per-core DC R recorded against lot number — Traceable
Continuous print line Voltage, size, ZC, meter length marked along jacket — Clear ID
Phase-color option Insulation or jacket color matched to phase code — Fast wiring
Light drum handling Reels load with standard equipment for fast dispatch — Fast delivery
09 · Installation
Laying Tray, conduit, riser, sub-main branch — Power
Connectors Cu lugs, standard glands — General
Bend radius ≥ 15×OD ≈ 248 mm — Single-core
Parallel runs Observe phase spacing / derating when bundled — Load
Site test Continuity + insulation post-laying — Commissioning
10 · Packing & Applications
Supply length Custom / wooden drum m Single-core
Reel type Standard wooden drum — Light
Surface marking ZC-YJV, 1×70, 0.6/1kV, ZC, length — Marking
Typical use Sub-main, branch power, motor short lead, panel feed — Power


Cable Test Parameters


Test Parameters — ZC-YJV 1×70 LV Flame-Retardant Cable (Rich Set)
No. Test Item Test Condition / Method Requirement Type
1 Conductor DC resistance 20 °C, core 70 ≤0.268 Ω/km Routine
2 Voltage test (AC) 3.5 kV AC, 5 min No breakdown Routine
3 Insulation resistance XLPE, 20°C High & stable Routine
4 Continuity Core Continuous Routine
5 Flame retardancy Class C vertical test Self-extinguish Type
6 Sheath thickness Micrometer Nominal ≥1.7 mm Routine
7 Insulation thickness Micrometer Nominal ≥1.4 mm Routine
8 Dimensional check Caliper OD ≈ 16.5 mm Routine
9 Conductor construction Visual / strand count Class 2 compacted Routine
10 Short-circuit rating Calculated / type 6.2 kA / 1 s Type
11 Insulation eccentric test Cross-section measure Within tolerance Routine
12 Sheath appearance Visual Smooth, no flaw Routine
13 Printing legibility Visual Marking readable Routine
14 Mass per unit length Weigh / calculate ≈ 870 kg/km Routine


Cable Cross Section Structure


1 X 70mm2 Single Core Cable Solid Copper XLPE Insulation PVC Jacket For Building Power


ZC-YJV 1×70 — Cross-Section Construction Diagram (Schematic)
Cu core / XLPE insulation / PVC ZC sheath · 0.6/1 kV · ZC class C flame retardant · ≈ 16.5 mm · sub-main & branch power
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductor 1×70 compacted Cu, Class 2, ≈19 strands — ≈ 11 Power core
2 XLPE insulation Cross-linked PE ≈ 1.4 ≈ 13.7 90°C dielectric
3 PVC sheath ZC flame-retardant ≈ 1.7 ≈ 16.5 Protection
Key Dimensions & Properties (expanded)
Finished cable diameter ≈ 16.5 mm Single core
Approx. cable mass ≈ 870 kg/km Cu core
Nominal voltage rating 0.6/1 kV LV
Max voltage (Um) 1.2 kV Phase-earth
Normal conductor temp. 90 °C Continuous
Short-circuit temp. 250 °C Short time
Flame retardancy ZC class C, self-extinguishing — Not fire-rated
Min bending radius (fixed) ≥ 15 × OD ≈ 248 mm Single-core
DC resistance (70) ≤ 0.268 Ω/km Cu 70
Nominal current (70 core) ≈ 195 A Air, 30°C
Short-circuit rating (1s) ≈ 6.2 kA 70 Cu
Frequency 50 / 60 Hz General
Core configuration 1×70 — Single
Application Sub-main, branch, motor lead — Power
Schematic — not to exact scale. OD ≈16.5 mm and weight ≈870 kg/km from cross-referenced industry samples. ZC-YJV 1×70 is a general LV flame-retardant power cable for sub-main, branch power and motor short leads; ZC class C self-extinguishes but is not 950°C fire-rated. Values marked (est.) require confirmation against the factory test certificate.


Cable Construction Description


Construction Description — ZC-YJV 1×70 LV flame-retardant power cable (rich)
Cu core / XLPE insulation / PVC ZC sheath · 0.6/1 kV · ZC class C · 90°C · ≈16.5 mm · sub-main & branch




1. Product Identity & Ratings
ZC-YJV 1×70 rated 0.6/1 kV (Um 1.2), 90°C working, ZC class C flame retardant. OD ≈16.5 mm, ≈870 kg/km, ≈195 A, standard wooden drum.




2. Copper Conductor (1×70)
Single 70 mm² compacted Class 2 Cu core, ≈19 concentric strands; DC R ≤0.268 Ω/km @20°C; tinned optional.




3. XLPE Insulation
Cross-linked PE ≈1.4 mm gives a stable 90°C dielectric; short-circuit limit 250°C; phase color on request.




4. PVC ZC Sheath
Flame-retardant PVC ≈1.7 mm, self-extinguishing class C; slate indigo finish; indoor/tray use.




5. Factory Advantages
• Compacted round core, clean conduit fit.  • Controlled XLPE cure.  • Dosed ZC self-extinguish compound.  • Cut to exact meter.  • Per-batch resistance log.  • Continuous clear print.  • Phase-color option.  • Light drum, standard handling.




6. Site Handling Notes
• Bend 15×OD (≈248 mm).  • Cu lugs, standard glands.  • Derate when bundled.  • Indoor; UV grade if exposed.  • Continuity + insulation after laying.


8. Factory Advantages.

  • Compacted round core — press-lay keeps OD tight for clean conduit fit and a smooth pull.
  • Controlled XLPE cure — even cross-linking line keeps the 90°C dielectric stable lot to lot.
  • Dosed ZC compound — flame-retardant PVC dosed to class C self-extinguish, with a safety margin.
  • Length-on-demand — cut to the exact meter with sealed ends and minimal offcut.
  • Batch resistance log — per-core DC R recorded against the lot number for traceability.
  • Continuous print line — voltage, size, ZC, and meter length marked along the jacket.
  • Phase-color option — insulation or jacket color matched to the phase code for faster wiring.
  • Light drum handling — reels load with standard equipment for fast dispatch.

1 X 70mm2 Single Core Cable Solid Copper XLPE Insulation PVC Jacket For Building Power


9. Packaging, Storage & Logistics. Standard wooden drum; continuous marking (ZC-YJV, 1×70, 0.6/1kV, ZC, length). Store dry, indoor; avoid UV; lighter reels suit standard handling.


1 X 70mm2 Single Core Cable Solid Copper XLPE Insulation PVC Jacket For Building Power


10. Procurement Specification. State "ZC-YJV 1×70", length, class C, and phase-color need; note it is flame retardant, not fire-rated; request the per-batch resistance log.


1 X 70mm2 Single Core Cable Solid Copper XLPE Insulation PVC Jacket For Building Power



ZC-YJV 1×70 mm² Power Cable
Frequently Asked Questions (FAQ)
Flame-Retardant Class C · XLPE Insulated · PVC Sheathed · Copper Conductor · 0.6/1 kV

Product Basics

Q1. What does the model “ZC-YJV” mean?
“Z” stands for flame-retardant, “C” denotes Class C flame-retardant performance, “YJ” means XLPE (cross-linked polyethylene) insulation, and “V” means PVC sheath. ZC-YJV is a copper-core, Class C flame-retardant, XLPE-insulated, PVC-sheathed low-voltage power cable.
Q2. What does “1×70 mm²” indicate?
“1” means a single-core cable. “70 mm²” is the nominal cross-sectional area of the copper conductor. This size is typically used for main incoming feeders, transformer secondary connections, and large load circuits in commercial, industrial, and infrastructure projects.
Q3. What is the rated voltage?
The rated voltage U₀/U is 0.6/1 kV (0.6 kV phase-to-earth, 1 kV phase-to-phase), designed for low-voltage power transmission and distribution systems.
Q4. What materials are used in construction?
Conductor: plain copper, Class 2 stranded. Insulation: cross-linked polyethylene (XLPE). Outer sheath: flame-retardant PVC. Standard ZC-YJV is unarmored. For direct burial or locations requiring mechanical protection, armored variants such as ZC-YJV22 (double steel tape) or ZC-YJV32 (fine steel wire) are recommended.

Technical Specifications

Q5. What is the maximum operating temperature?
The maximum continuous conductor temperature is 90 °C. During short-circuit events, the conductor may reach up to 250 °C for no more than 5 seconds. XLPE insulation provides high thermal stability and excellent current-carrying capacity for heavy-duty applications.
Q6. What is the typical current-carrying capacity?
For a 1×70 mm² copper XLPE cable, the ampacity is approximately 210–260 A when installed in free air at 30 °C ambient. Lower ratings apply when buried, installed in conduit, grouped with other cables, or at elevated ambient temperatures. For precise engineering design, consult the manufacturer's ampacity tables (GB/T 16895 / IEC 60364) and apply appropriate derating factors.
Q7. What is the conductor DC resistance?
The maximum DC resistance of a 70 mm² Class 2 copper conductor at 20 °C is approximately 0.268 Φ/km (annealed copper), per GB/T 3956 / IEC 60228. The exact value should be verified against the factory test report for each production batch.

Installation & Applications

Q8. What is the minimum bending radius?
For single-core unarmored cables of this size, the minimum bending radius is 20 times the cable outer diameter (20D) during installation, with 15D acceptable for static installation. Larger cross-section cables are stiffer and require more careful handling. D = actual outer diameter.
Q9. What are the typical applications?
Common uses include: main incoming power feeders in commercial and industrial buildings; connection between low-voltage distribution transformers and main switchgear; supply to large motors, UPS systems, and HVAC plants; and primary power distribution in infrastructure projects where Class C flame-retardant performance is required.
Q10. Which standards and certifications apply?
Manufactured in accordance with GB/T 12706 (equivalent to IEC 60502), with conductor compliance to GB/T 3956 / IEC 60228 and flame-retardant testing per GB/T 18380 / IEC 60332-3. Common certifications include CCC (China), CE (Europe), ISO 9001, RoHS, and VDE/TUV for specific international markets.