logo
Anhui Tongdu International Trade Co., Ltd.
Online Service

Online Service

Contact Person
+86 19056002718
WeChat QR Code
Follow Us

1 X 70mm2 Single Core Cable Solid Copper XLPE Insulation PVC Jacket For Building Power

1 X 70mm2 Single Core Cable Solid Copper XLPE Insulation PVC Jacket For Building Power

Basic Properties

country of origin
China
brand name
TD
certificate
CE/ISO/CCC
product model
ZR-YJV 1*70mm²

Trading Properties

moq
100 meters
payment method
L/C,T/T
supply capacity
100000 meters per month

Product Summary

ZR-YJV 1*70mm² Single Conductor , 0.6/1kV Solid Copper, XLPE Insulation PVC Jacket for Building Power Code Mean:ZR-Flame Retardant, YJ-XLPE Insulation, V-PVC Outer Sheathed ZR-YJV 1×70 mm² — Detailed Product Introduction ZR-YJV 1×70 is a flame-retardant, copper-conductor, XLPE-insulated, PVC...

Product Details

Highlight:

1 x 70mm2 Single Core Cable

,

Single Core Cable non hygroscopic

,

Building Powerpvc jacket cable

Conductor:
Bare Annealed Copper, Class 2 Stranded Circular, 19×∅2.22 Mm​ (typical), Conductor Ø ≈ 11.0 Mm
Conductor nominal area:
70 Mm²
Conductor construction:
Class 2, 19×∅2.22 Mm​ Min. 19 Wires Per GB/T 3956 (>35 Mm²)
Conductor diameter (approx.):
11.0 Mm
Insulation:
XLPE Compound, Extruded
Insulation thickness:
1.1 Mm​ (GB/T 12706.1, 70 Mm² Class)
Diameter over insulation (approx.):
13.2 Mm(11.0 + 2×1.1)
Filler / binder:
Flame-retardant (FR) Non-hygroscopic Tape / PP Mesh
Outer sheath:
Flame-retardant PVC Compound (ZR Grade)​
Sheath thickness:
1.4 Mm​ (single-core; Some Makers Use 1.5 Mm For 70 Mm² — Verify Per Factory)
Overall cable diameter:
17.3 – 18.5 Mm​ PVC Density; Use 17.8 Mm For Design
Approx. weight:
700 – 750 Kg/km
Long-term service temperature:
90 °C
Short-circuit temperature (≤5 s):
250 °C
Emergency overload:
105–130 °C (limited Duration)
Routine test:
3.5 KV AC / 5 Min; Type Test 4.0 KV
Volume resistivity @90 °C:
≥ 10¹² Ω·cm

Product Description

ZR-YJV 1*70mm² Single Conductor , 0.6/1kV Solid Copper, XLPE Insulation PVC Jacket for Building Power

 

Code Mean:ZR-Flame Retardant, YJ-XLPE Insulation, V-PVC Outer Sheathed

 

ZR-YJV 1×70 mm² — Detailed Product Introduction

ZR-YJV 1×70 is a flame-retardant, copper-conductor, XLPE-insulated, PVC-sheathed power cable for 0.6/1 kV distribution, designed and tested to GB/T 12706.1 and IEC 60502-1.

1. Product Structure (from conductor to outer sheath)

 

No. Layer Material / Construction Key data
1 Conductor (Cu) Plain annealed copper, Class 1/2 (typical Class 2 stranded), nominal 70 mm² Typical stranding 19 × 2.14 mm (19/2.14, lay-up 1+6+12); Ø ≈ 9.6 mm (9.6–10.7 mm); max. DC resistance ≤ 0.268 Ω/km @ 20 °C (GB/T 3956)
2 Insulation (XLPE) Cross-linked polyethylene (thermoset) Nominal thickness 1.1 mm; Ø over insulation ≈ 11.8 mm; 90 °C continuous rating
3 Outer sheath (PVC) Flame-retardant PVC, ST2 type, black Nominal thickness 1.5 mm; overall Ø ≈ 15.3–15.6 mm; flame retardance ZC (ZR)

Overall diameter ≈ 15.6 mm (15.3–15.6 mm) and weight ≈ 609 kg/km (600–609 kg/km).

 

2. Product Performance

  • Electrical: Conductor DC resistance ≤ 0.268 Ω/km @ 20 °C; routine AC withstand test 3.5 kV / 5 min without breakdown; finished-cable insulation resistance ≥ 36.7 MΩ·km @ 20 °C (typical reference); XLPE volume resistivity ≥ 1×10¹² Ω·cm; capacitance ≤ 0.45 μF/km.
  • Thermal: Max. continuous conductor temperature 90 °C; short-circuit (≤ 5 s) 250 °C; ambient service −20 to +45 °C; laying temperature not below 0 °C.
  • Flame retardance: "ZR" = flame-retardant, default class ZC per GB/T 19666; passes single-cable vertical flame test (GB/T 18380.12) and class-C bunched test (GB/T 18380.35: ≥ 1.5 L/m non-metallic volume, 20 min flame, char extent ≤ 2.5 m).
  • Ampacity (reference): ≈ 285 A in air (single core, 30 °C); direct burial ≈ 250–285 A depending on soil thermal resistivity — always apply correction factors per GB/T 16895 / IEC 60364.
  • Mechanical/installation: min. bending radius 20 × OD (single-core); site DC withstand test after installation 4U0 = 2.4 kV / 15 min (per Q/GDW 13244.1-2018 practice).

1 X 70mm2 Single Core Cable Solid Copper XLPE Insulation PVC Jacket For Building Power

3. Key Parameters

  • Rated voltage 0.6/1 kV (Um = 1.2 kV); 50 Hz; single core; 70 mm²
  • Conductor: Cu Class 2, 19 × 2.14 mm, Ø ≈ 9.6 mm; DC R ≤ 0.268 Ω/km
  • Insulation: XLPE, 1.1 mm; Sheath: flame-retardant PVC ST2, 1.5 mm
  • Weight ≈ 609 kg/km; OD ≈ 15.6 mm; length 100 m per coil/drum
ZR-YJV 1×70 mm² Flame-Retardant Copper-Conductor XLPE-Insulated PVC-Sheathed Power Cable — Product Parameters (0.6/1 kV)
Construction: CU / XLPE / PVC  •  Standards: GB/T 12706.1, IEC 60502-1 (cable), GB/T 3956 (conductor), GB/T 19666 & GB/T 18380 (flame retardance)  •  Nominal values for reference — confirm against factory test certificate
No. Category Parameter Value Unit Notes / Standard Reference
A. Product Identification
1 Identification Product name Flame-retardant copper-conductor XLPE-insulated PVC-sheathed power cable — Designation ZR-YJV; "ZR" = flame-retardant (halogen-containing)
2 Identification Model designation ZR-YJV 1×70 — Cu / XLPE / PVC
3 Identification Design standards GB/T 12706.1; IEC 60502-1 — Conductor: GB/T 3956 / IEC 60228; flame retardance: GB/T 19666, GB/T 18380; safety: CCC / production licence
4 Identification Rated voltage U0/U 0.6/1 kV Max system voltage Um = 1.2 kV
5 Identification Rated frequency 50 Hz AC power distribution
6 Identification Number of cores 1 — Single-core cable
7 Identification Nominal cross-sectional area 70 mm² Nominal conductor cross-section per GB/T 3956
B. Cable Construction (from conductor to outer sheath)
8 Conductor Material Plain annealed copper (Cu) — High-conductivity electrolytic / oxygen-free copper
9 Conductor Conductor class Class 1 or Class 2 (typical: Class 2, stranded) — GB/T 3956 / IEC 60228
10 Conductor Typical stranding construction 19 wires × 2.14 mm (19/2.14) — Class 2 round stranded; nominal section ≈ 70 mm²
11 Conductor Conductor diameter ≈ 9.6 mm 9.6–10.7 mm per manufacturer tables (Qifan 9.6 mm; 19/2.14 → ≈ 10.7 mm)
12 Conductor Max. DC resistance of conductor at 20 °C 0.268 Ω/km GB/T 3956, Class 2 copper; acceptance criterion for 70 mm²
13 Insulation Material Cross-linked polyethylene (XLPE) — Thermally cross-linked; natural/transparent colour
14 Insulation Nominal insulation thickness 1.1 mm GB/T 12706.1 / IEC 60502-1 (0.6/1 kV, 70 mm²)
15 Insulation Diameter over insulation ≈ 11.8 mm ≈ 9.6 + 2 × 1.1 (calculated)
16 Sheath Material Flame-retardant polyvinyl chloride (PVC, ST2 type) — Colour: black (or as ordered)
17 Sheath Nominal sheath thickness 1.5 mm GB/T 12706.1 / IEC 60502-1
18 Dimensions Approx. overall diameter 15.3–15.6 mm Qifan 15.6 mm; Weiguang 15.3 mm
19 Dimensions Approx. cable weight ≈ 609 kg/km Range 600–609 kg/km across manufacturers (Qifan 609; Weiguang 600)
C. Electrical Performance
20 Electrical Max. DC conductor resistance at 20 °C 0.268 Ω/km GB/T 3956; routine measurement
21 Electrical Power-frequency withstand voltage (routine test) 3.5 kV / 5 min, no breakdown — AC 50 Hz; per GB/T 12706.1 / IEC 60502-1
22 Electrical Insulation resistance (finished cable, 20 °C) ≥ 36.7 MΩ·km Typical finished-cable requirement for 0.6/1 kV XLPE cables; varies with geometry and manufacturer test method
23 Electrical XLPE volume resistivity at 20 °C ≥ 1 × 10¹² Ω·cm Material-level requirement (manufacturer reference)
24 Electrical Capacitance (single-core, approx.) ≤ 0.45 μF/km Manufacturer reference value
25 Electrical Reference ampacity — in air, 30 °C, single core ≈ 285 A Reference value (Guangheng); depends on laying, grouping, ambient — apply correction factors per GB/T 16895 / IEC 60364
26 Electrical Reference ampacity — direct burial, 25 °C ≈ 250–285 A Reference value; depends on soil thermal resistivity and depth (reference range)
D. Thermal Performance
27 Thermal Max. continuous conductor temperature 90 °C XLPE insulation temperature class
28 Thermal Max. conductor temperature under short-circuit (≤ 5 s) 250 °C Per GB/T 12706.1 / IEC 60502-1
29 Thermal Ambient service temperature range -20 to +45 °C Per Qifan datasheet; check project specification
30 Thermal Min. installation (laying) temperature 0 °C Pre-heat the cable if ambient is below 0 °C
E. Flame Retardance (ZR)
31 Flame retardance Flame-retardant class ZC (class C) by default for "ZR" — GB/T 19666; ZA / ZB available on request; halogen-containing PVC (not LSZH)
32 Flame retardance Single-cable vertical flame-spread test Pass — GB/T 18380.12
33 Flame retardance Bunched flame-spread test (class C) Char extent ≤ 2.5 m above burner bottom edge — GB/T 18380.35: non-metallic volume ≥ 1.5 L/m; flame application 20 min
34 Flame retardance Halogen content Halogen-containing (PVC) — For low-smoke, zero-halogen requirement select WDZ-YJY (LSZH) type
F. Installation
35 Installation Min. bending radius — single-core cable 20 × OD — Qifan & Huaneng datasheets; some manufacturers specify 15 × OD; OD = actual cable diameter
36 Installation Laying methods Conduit, tray, cable trench, tunnel, duct, supported/suspended aerial — Also direct burial with mechanical protection where permitted
37 Installation Site withstand test after installation DC 4U0 = 2.4 kV, 15 min (recommended) — Per utility procurement standard Q/GDW 13244.1-2018; practice may vary by project
G. Packing & Delivery
38 Packing Standard delivery length 100 m per coil/drum (or as ordered) — Typical industry practice; custom lengths available
39 Packing Cable marking Model, rated voltage, manufacturer, year of manufacture, sequential length marks — Per GB/T 6995 / project specification
40 Packing Packing form Wooden drum / coil / export packing — As per customer requirement

 

4. Test Parameters

Routine: DC resistance ≤ 0.268 Ω/km; AC 3.5 kV/5 min; construction check. Sample: hot-set test on XLPE (200 ± 3 °C, 15 min, 0.2 MPa — elongation under load ≤ 175 %, permanent ≤ 15 %); conductor construction check (19 × 2.14 mm). Type: flame tests (GB/T 18380.12 / .35); bending test. Post-installation: DC 4U0 = 2.4 kV / 15 min.

 

ZR-YJV 1×70 mm² — Test / Verification Parameters (per GB/T 12706.1 & IEC 60502-1)
Test Stage Test Item Method / Standard Requirement / Acceptance Criterion Notes
Routine test Conductor DC resistance measurement GB/T 3956 (IEC 60228) ≤ 0.268 Ω/km at 20 °C Measured on every production length
Routine test Power-frequency withstand voltage GB/T 12706.1 / IEC 60502-1 3.5 kV AC, 5 min, no breakdown Applied between conductor and water/earth; 50 Hz
Routine test Construction check — insulation & sheath thickness, outer diameter GB/T 2951 Within GB/T 12706.1 tolerances Insulation ≥ 1.1 mm nominal; sheath ≥ 1.5 mm nominal
Sample test Hot set (thermal elongation) test — XLPE insulation GB/T 12706.1 §16.3.13 / GB/T 2951.11 200 ± 3 °C, 15 min, stress 0.2 MPa: elongation under load ≤ 175 %; permanent elongation after cooling ≤ 15 % Verifies degree of cross-linking
Sample test Conductor construction & diameter check GB/T 3956 Class 2; 19 × 2.14 mm; Ø ≈ 9.6 mm Sampled per batch
Type test Single-cable vertical flame-spread test (flame retardance) GB/T 18380.12 No flame spread; charring does not reach top reference point ZR / ZC flame-retardant property
Type test Bunched flame-spread test, class C GB/T 18380.35 Char extent ≤ 2.5 m above burner bottom edge; flame application 20 min; non-metallic volume ≥ 1.5 L/m Class ZC per GB/T 19666
Type test Bending test (mechanical) GB/T 12706.1 Bend around specified mandrel without insulation/sheath damage Mandrel diameter related to cable OD
Post-installation DC withstand test after installation Q/GDW 13244.1-2018 (recommended practice) 4U0 = 2.4 kV DC, 15 min, no breakdown For new installations; verify project specification
Optional Insulation resistance measurement at 20 °C Manufacturer test method ≥ 36.7 MΩ·km (typical finished-cable value) Not a routine item in GB/T 12706.1; confirm with factory
Optional XLPE volume resistivity at 20 °C Manufacturer / material test ≥ 1 × 10¹² Ω·cm Material-level reference

 

5. Cross Section Structure

 

1 X 70mm2 Single Core Cable Solid Copper XLPE Insulation PVC Jacket For Building Power

 

No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductor (Cu) Annealed copper, Class 2 stranded — 19 × 2.14 mm (19/2.14), nominal 70 mm² — ≈ 9.6 (Ø) Current-carrying element; max DC resistance ≤ 0.268 Ω/km @ 20 °C
2 Insulation (XLPE) Cross-linked polyethylene 1.1 ≈ 11.8 (Ø over insulation) Dielectric barrier; rated 90 °C continuous; withstands 3.5 kV / 5 min
3 Outer sheath (PVC) Flame-retardant PVC, ST2 type, black 1.5 ≈ 15.6 (Ø overall) Mechanical & moisture protection; flame retardance ZC (ZR) per GB/T 19666
     
   
Key Dimensions & Properties
Overall diameter 15.3–15.6 mm Qifan 15.6 mm; Weiguang 15.3 mm    
Approx. cable weight ≈ 609 kg/km Range 600–609 kg/km across manufacturers    
Rated voltage 0.6/1 kV AC 50 Hz; max system voltage Um = 1.2 kV    
Max conductor temperature 90 / 250 °C Continuous / short-circuit (≤ 5 s)    
Min. bending radius (single-core) 20 × OD — OD = actual cable diameter    
Flame-retardant class ZC (ZR) — GB/T 19666    

 

6. Usage Precautions

  1. Install only when ambient ≥ 0 °C; pre-heat the cable if colder.
  2. Min. bending radius 20 × OD — avoid sharp bends and kinking.
  3. ZR-YJV contains halogen (PVC); for LSZH requirements choose WDZ-YJY.
  4. Ampacity must be derated for grouping, ambient temperature and burial conditions.
  5. Perform the site DC test only after verifying insulation integrity; avoid prolonged overvoltage.
  6. Store on drums/coils, away from direct sunlight and mechanical damage.

7. Application Range

Indoor/outdoor distribution and branch circuits at 0.6/1 kV in industrial plants, commercial buildings, residential complexes, substations and similar installations — in conduits, trays, trenches, tunnels and ducts; suitable where flame-retardant performance is required (not for direct sunlight exposure unless UV-protected).

 

1 X 70mm2 Single Core Cable Solid Copper XLPE Insulation PVC Jacket For Building Power

 

8. Package

 

1 X 70mm2 Single Core Cable Solid Copper XLPE Insulation PVC Jacket For Building Power

 

9. Company Overview

 

1 X 70mm2 Single Core Cable Solid Copper XLPE Insulation PVC Jacket For Building Power

1 X 70mm2 Single Core Cable Solid Copper XLPE Insulation PVC Jacket For Building Power