1*150mm2 Single Core Copper Wire XLPE Insulation PVC Sheath For Construction Wiring

1*150mm2 Single Core Copper Wire XLPE Insulation PVC Sheath For Construction Wiring

Basic Properties

country of origin
China
brand name
TD
certificate
CE/ISO/CCC
product model
ZR-YJV 1*150mm²

Trading Properties

moq
1 Meter
payment method
L/C,T/T
supply capacity
10000 meters per month

Product Summary

ZR-YJV 1*150mm² Flame Retardant Copper Cable,0.6/1kV XLPE Insulation PVC Sheath for Construction Wiring Code Mean:ZR-Flame Retardant,YJ-XLPE Insulation,V-PVC Outer Sheathed. 1. Identity & Standards. The ZR-YJV 1×150 is a single-conductor, flame-retarded power cable with a CU/XLPE/PVC make-up, rated ...

Product Details

Highlight:

1*150mm2 single core copper wire

,

single core copper wire XLPE Insulation

,

Construction single core thin wall cable

Conductor​:
Bare Annealed Copper, Class 2 Stranded Circular, 37×∅2.27 Mm​ (typical), Conductor Ø ≈ 15.9 Mm
Conductor nominal area:
150 Mm²
Conductor construction:
Class 2, 37×∅2.27 Mm​ Min. 37 Wires Per GB/T 3956 (>95 Mm²)
Conductor diameter (approx.):
15.9 Mm
Insulation:
XLPE Compound, Extruded
Insulation thickness:
1.2 Mm​ (GB/T 12706.1, 150 Mm² Class)
Diameter over insulation (approx.):
18.3 Mm(15.9 + 2×1.2)
Sheath nominal thickness:
1.4 Mm​(single-core PVC)
Overall cable diameter:
23.5 – 24.5 Mm​,PVC Density; Use 24.0 Mm For Design
Approx. weight:
1,320 – 1,400 Kg/km​,PVC Heavier Than PO; Use ≈ 1,360 Kg/km
Long-term service temperature:
90 °C
Short-circuit temperature (≤5 s):
250 °C
Emergency overload:
105–130 °C (limited Duration)
Routine test:
3.5 KV AC / 5 Min; Type Test 4.0 KV
Volume resistivity @90 °C:
≥ 10¹² Ω·cm

Product Description

ZR-YJV 1*150mm² Flame Retardant Copper Cable,0.6/1kV XLPE Insulation PVC Sheath for Construction Wiring

 

Code Mean:ZR-Flame Retardant,YJ-XLPE Insulation,V-PVC Outer Sheathed.

 

1. Identity & Standards. The ZR-YJV 1×150 is a single-conductor, flame-retarded power cable with a CU/XLPE/PVC make-up, rated 0.6/1 kV (Um = 1.2 kV) at 50 Hz. It is manufactured and type-tested to GB/T 12706.1 / IEC 60502-1; the conductor complies with GB/T 3956 / IEC 60228; the "ZR" fire-retardant property follows GB/T 19666 and GB/T 18380. Default fire class is ZC unless ZA/ZB is ordered.

 

1*150mm2 Single Core Copper Wire XLPE Insulation PVC Sheath For Construction Wiring

 

2. Construction Detail. Cross-section, inside out:

Layer Composition Thickness Diameter
Conductor Annealed copper, Class 2, 30 × 2.52 mm (30/2.52) stranded, 150 mm² — ≈ 13.8 mm (compacted; up to ≈ 15.3 mm round-lay)
Insulation Cross-linked polyethylene (XLPE) 1.4 mm ≈ 16.6 mm over insulation
Sheath Flame-retarded PVC, ST2, black 2.0 mm ≈ 20.6 mm overall

Mass ≈ 1590 kg/km (copper alone ≈ 1333 kg/km); overall diameter 20.6–21 mm (some makers quote up to 23 mm including tolerance).

 

1*150mm2 Single Core Copper Wire XLPE Insulation PVC Sheath For Construction Wiring

 

3. Electrical Characteristics. Max DC resistance ≤ 0.124 Ω/km at 20 °C; routine withstand 3.5 kV AC / 5 min; XLPE volume resistivity ≥ 1×10¹² Ω·cm; finished-cable insulation resistance typically ≥ 36.7 MΩ·km; capacitance ≤ 0.45 μF/km. Reference ampacity ≈ 460 A in air (30 °C, single core) and ≈ 425 A direct-buried — derate for grouping, ambient and method (GB/T 16895 / IEC 60364).

 

Parameter

Value

Note

Rated voltage U₀/U

0.6 / 1 kV

Uₘ = 1.2 kV

Test voltage AC (5 min)

3.5 kV​

Routine

Type-test voltage

4.0 kV

IEC 60502

DC resistance @20 °C (Class 2 Cu)​

≤ 0.124 Ω/km​

GB/T 3956 / IEC 60228 max

AC resistance @90 °C (est.)

≈ 0.161 Ω/km

copper temp. coefficient

Current rating in air (30–40 °C, single circuit, single-core)

≈ 440 – 455 A​

PVC sheath; design ≈ 440 A​

Direct buried (20 °C, soil 1.0 K·m/W, 0.7 m)

≈ 400 – 415 A​

design ≈ 400 A​

Short-circuit current (1 s adiabatic, Cu, 250 °C)

≈ 17.32 kA

reference

Frequency

50/60 Hz AC (DC usable)

—

 

4. Thermal & Physical Data. Continuous conductor rating 90 °C; short-circuit ceiling 250 °C (≤ 5 s); ambient −20 to +45 °C; installation not below 0 °C without pre-warming; minimum bending radius 20 × OD for single-core runs.

 

ZR-YJV 1×150 mm² Flame-Retardant Copper-Conductor XLPE-Insulated PVC-Sheathed Power Cable — Product Parameters (0.6/1 kV)
Construction: CU / XLPE / PVC  •  Standards: GB/T 12706.1, IEC 60502-1 (cable), GB/T 3956 (conductor), GB/T 19666 & GB/T 18380 (flame retardance)  •  Nominal values for reference — confirm against factory test certificate
No. Category Parameter Value Unit Notes / Standard Reference
A. Product Identification
1 Identification Product name Flame-retardant copper-conductor XLPE-insulated PVC-sheathed power cable — Designation ZR-YJV; "ZR" = flame-retardant (halogen-containing)
2 Identification Model designation ZR-YJV 1×150 — Cu / XLPE / PVC
3 Identification Design standards GB/T 12706.1; IEC 60502-1 — Conductor: GB/T 3956 / IEC 60228; flame retardance: GB/T 19666, GB/T 18380; safety: CCC / production licence
4 Identification Rated voltage U0/U 0.6/1 kV Max system voltage Um = 1.2 kV
5 Identification Rated frequency 50 Hz AC power distribution
6 Identification Number of cores 1 — Single-core cable
7 Identification Nominal cross-sectional area 150 mm² Nominal conductor cross-section per GB/T 3956
B. Cable Construction (from conductor to outer sheath)
8 Conductor Material Plain annealed copper (Cu) — High-conductivity electrolytic / oxygen-free copper
9 Conductor Conductor class Class 1 or Class 2 (typical: Class 2, stranded) — GB/T 3956 / IEC 60228
10 Conductor Typical stranding construction 30 wires × 2.52 mm (30/2.52) — Class 2 round stranded; nominal section ≈ 150 mm²
11 Conductor Conductor diameter ≈ 13.8 mm ≈ 13.8 mm compact (13.8–15.3 mm across stranding practice)
12 Conductor Max. DC resistance of conductor at 20 °C 0.124 Ω/km GB/T 3956, Class 2 copper; acceptance criterion for 150 mm²
13 Insulation Material Cross-linked polyethylene (XLPE) — Thermally cross-linked; natural/transparent colour
14 Insulation Nominal insulation thickness 1.4 mm GB/T 12706.1 / IEC 60502-1 (0.6/1 kV, 150 mm²)
15 Insulation Diameter over insulation ≈ 16.6 mm ≈ 13.8 + 2 × 1.4 (calculated, compact conductor)
16 Sheath Material Flame-retardant polyvinyl chloride (PVC, ST2 type) — Colour: black (or as ordered)
17 Sheath Nominal sheath thickness 2.0 mm GB/T 12706.1 / IEC 60502-1 (cabhr & Hongqi tables)
18 Dimensions Approx. overall diameter 20.6 mm ≈ 20.6 mm (20.6–21 mm; some makers list up to 23 mm incl. tolerance)
19 Dimensions Approx. cable weight ≈ 1590 kg/km cabhr / Hongqi / Lvbao agree at 1590 kg/km (copper core alone ≈ 1333 kg/km)
C. Electrical Performance
20 Electrical Max. DC conductor resistance at 20 °C 0.124 Ω/km GB/T 3956; routine measurement
21 Electrical Power-frequency withstand voltage (routine test) 3.5 kV / 5 min, no breakdown — AC 50 Hz; per GB/T 12706.1 / IEC 60502-1
22 Electrical Insulation resistance (finished cable, 20 °C) ≥ 36.7 MΩ·km Typical finished-cable reference for 0.6/1 kV XLPE cables; varies with geometry and manufacturer test method
23 Electrical XLPE volume resistivity at 20 °C ≥ 1 × 10¹² Ω·cm Material-level requirement (manufacturer reference)
24 Electrical Capacitance (single-core, approx.) ≤ 0.45 μF/km Manufacturer reference value
25 Electrical Reference ampacity — in air, 30 °C, single core ≈ 460 A cabhr table (460 A); depends on laying, grouping, ambient — apply correction factors per GB/T 16895 / IEC 60364
26 Electrical Reference ampacity — direct burial, 25 °C ≈ 425 A cabhr table; depends on soil thermal resistivity and depth
D. Thermal Performance
27 Thermal Max. continuous conductor temperature 90 °C XLPE insulation temperature class
28 Thermal Max. conductor temperature under short-circuit (≤ 5 s) 250 °C Per GB/T 12706.1 / IEC 60502-1
29 Thermal Ambient service temperature range -20 to +45 °C Per Qifan datasheet family; check project specification
30 Thermal Min. installation (laying) temperature 0 °C Pre-heat the cable if ambient is below 0 °C
E. Flame Retardance (ZR)
31 Flame retardance Flame-retardant class ZC (class C) by default for "ZR" — GB/T 19666; ZA / ZB available on request; halogen-containing PVC (not LSZH)
32 Flame retardance Single-cable vertical flame-spread test Pass — GB/T 18380.12
33 Flame retardance Bunched flame-spread test (class C) Char extent ≤ 2.5 m above burner bottom edge — GB/T 18380.35: non-metallic volume ≥ 1.5 L/m; flame application 20 min
34 Flame retardance Halogen content Halogen-containing (PVC) — For low-smoke, zero-halogen requirement select WDZ-YJY (LSZH) type
F. Installation
35 Installation Min. bending radius — single-core cable 20 × OD — Qifan & Huaneng datasheets; OD = actual cable diameter
36 Installation Laying methods Conduit, tray, cable trench, tunnel, duct, supported/suspended aerial — Also direct burial with mechanical protection where permitted
37 Installation Site withstand test after installation DC 4U0 = 2.4 kV, 15 min (recommended) — Per utility procurement standard Q/GDW 13244.1-2018; practice may vary by project
G. Packing & Delivery
38 Packing Standard delivery length 100 m per coil/drum (or as ordered) — Typical industry practice; custom lengths available
39 Packing Cable marking Model, rated voltage, manufacturer, year of manufacture, sequential length marks — Per GB/T 6995 / project specification
40 Packing Packing form Wooden drum / coil / export packing — As per customer requirement

 

5. Flame-Retardance & Environment. The ST2 PVC jacket passes the single vertical burn (GB/T 18380.12) and the class-C bunched burn (GB/T 18380.35: ≥ 1.5 L/m non-metallic content, 20 min, char ≤ 2.5 m), earning class ZC per GB/T 19666. PVC releases halogen under fire — select WDZ-YJY where low-smoke zero-halogen is specified.

 

6. Test Regime. Routine: DC resistance ≤ 0.124 Ω/km; 3.5 kV/5 min; construction audit (insulation ≥ 1.4 mm, sheath ≥ 2.0 mm). Sample: hot-set on XLPE (200 ± 3 °C, 15 min, 0.2 MPa — elongation ≤ 175 %, permanent set ≤ 15 %); stranding/diameter check. Type: flame and bending tests. Post-install: DC 4U0 = 2.4 kV / 15 min (Q/GDW 13244.1-2018 practice).

 

ZR-YJV 1×150 mm² — Test / Verification Parameters (per GB/T 12706.1 & IEC 60502-1)
Test Stage Test Item Method / Standard Requirement / Acceptance Criterion Notes
Routine test Conductor DC resistance measurement GB/T 3956 (IEC 60228) ≤ 0.124 Ω/km at 20 °C Measured on every production length
Routine test Power-frequency withstand voltage GB/T 12706.1 / IEC 60502-1 3.5 kV AC, 5 min, no breakdown Applied between conductor and water/earth; 50 Hz
Routine test Construction check — insulation & sheath thickness, outer diameter GB/T 2951 Within GB/T 12706.1 tolerances Insulation ≥ 1.4 mm nominal; sheath ≥ 2.0 mm nominal
Sample test Hot set (thermal elongation) test — XLPE insulation GB/T 12706.1 §16.3.13 / GB/T 2951.11 200 ± 3 °C, 15 min, stress 0.2 MPa: elongation under load ≤ 175 %; permanent elongation after cooling ≤ 15 % Verifies degree of cross-linking
Sample test Conductor construction & diameter check GB/T 3956 Class 2; 30 × 2.52 mm; Ø ≈ 13.8 mm Sampled per batch
Type test Single-cable vertical flame-spread test (flame retardance) GB/T 18380.12 No flame spread; charring does not reach top reference point ZR / ZC flame-retardant property
Type test Bunched flame-spread test, class C GB/T 18380.35 Char extent ≤ 2.5 m above burner bottom edge; flame application 20 min; non-metallic volume ≥ 1.5 L/m Class ZC per GB/T 19666
Type test Bending test (mechanical) GB/T 12706.1 Bend around specified mandrel without insulation/sheath damage Mandrel diameter related to cable OD
Post-installation DC withstand test after installation Q/GDW 13244.1-2018 (recommended practice) 4U0 = 2.4 kV DC, 15 min, no breakdown For new installations; verify project specification
Optional Insulation resistance measurement at 20 °C Manufacturer test method ≥ 36.7 MΩ·km (typical finished-cable value) Not a routine item in GB/T 12706.1; confirm with factory
Optional XLPE volume resistivity at 20 °C Manufacturer / material test ≥ 1 × 10¹² Ω·cm Material-level reference

 

7.Cross Section Structure

1*150mm2 Single Core Copper Wire XLPE Insulation PVC Sheath For Construction Wiring

 

ZR-YJV 1×150 mm² — Cable Cross-Section Structure (Schematic)
Layers from conductor to outer sheath · nominal values per GB/T 12706.1 / IEC 60502-1 · not to exact scale
           
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductor (Cu) Annealed copper, Class 2 stranded — 30 × 2.52 mm (30/2.52), nominal 150 mm² — ≈ 13.8 (Ø) Current-carrying element; max DC resistance ≤ 0.124 Ω/km @ 20 °C
2 Insulation (XLPE) Cross-linked polyethylene 1.4 ≈ 16.6 (Ø over insulation) Dielectric barrier; rated 90 °C continuous; withstands 3.5 kV / 5 min
3 Outer sheath (PVC) Flame-retardant PVC, ST2 type, black 2 ≈ 20.6 (Ø overall) Mechanical & moisture protection; flame retardance ZC (ZR) per GB/T 19666
Key Dimensions & Properties
Overall diameter 20.6 mm 20.6–21 mm (up to 23 mm incl. tolerance); cabhr 20.6; Hongqi 21    
Approx. cable weight ≈ 1590 kg/km cabhr / Hongqi / Lvbao agree; Cu core alone ≈ 1333 kg/km    
Rated voltage 0.6/1 kV AC 50 Hz; max system voltage Um = 1.2 kV    
Max conductor temperature 90 / 250 °C Continuous / short-circuit (≤ 5 s)    
Min. bending radius (single-core) 20 × OD — OD = actual cable diameter    
Flame-retardant class ZC (ZR) — GB/T 19666    

 

8. Handling & Safety Notes. Unroll from the drum without twisting the single core; avoid kinking at terminations; protect the sheath from UV and sharp edges during and after laying; run the site DC test and verify insulation integrity before energising; never exceed the 3.5 kV/5 min level for site checks unless the project allows otherwise.

 

9. Applications. Heavy low-voltage feeders, large motor and pump circuits, transformer secondary connections, main switchboard tails and industrial distribution risers — in trays, conduits, trenches, tunnels and ducts, indoors or in sheltered outdoor positions.

 

1*150mm2 Single Core Copper Wire XLPE Insulation PVC Sheath For Construction Wiring

 

10. Packing & Ordering. Normally delivered 100 m per drum/coil, with standard marking (model, voltage, maker, year, length marks). Order: ZR-YJV 0.6/1 kV 1×150, with length and drum type. Reconcile all data against the factory certificate and GB/T 12706.1 / IEC 60502-1 test report before installation.