5x4mm2 5 Core Flexible Cable Transmission Control PVC Sheathed Stranded Copper Conductor

5x4mm2 5 Core Flexible Cable Transmission Control PVC Sheathed Stranded Copper Conductor

Basic Properties

country of origin
China
brand name
TD
certificate
CE/ISO/CCC
product model
RVV-5*4.0mm²

Trading Properties

moq
100 meters
payment method
L/C,T/T
supply capacity
100000 meters per month

Product Summary

Premium RVV-5*4mm² Flexible Transmission Control Cable Stranded Copper PVC Insulated and Outer Sheathed RVV 5×4 mm² Copper Conductor PVC Insulated & Sheathed Flexible Cord Type:​ 60227 IEC 53 (RVV) · Voltage:​ 300/500 V · Standard:​ GB/T 5023.5-2008 / IEC 60227-5:2003 · Certification:​ CCC · Origin:...

Product Details

Highlight:

5x4mm2 5 Core Flexible Cable

,

Transmission Control 5 Core Flexible Cable

,

PVC stranded copper conductor

Conductor:
Stranded Copper
Copper:
99.99% Oxygen-free Copper
Insulation:
PVC
Outer Sheath:
PVC
Voltage:
300-500V
Temperature:
70℃
Filler:
PP
Model Type:
Flexible
Package:
As Requirements

Product Description

Premium RVV-5*4mm² Flexible Transmission Control Cable Stranded Copper PVC Insulated and Outer Sheathed

 

RVV 5×4 mm² Copper Conductor PVC Insulated & Sheathed Flexible Cord

Type:​ 60227 IEC 53 (RVV) · Voltage:​ 300/500 V · Standard:​ GB/T 5023.5-2008 / IEC 60227-5:2003 · Certification:​ CCC · Origin:​ Anhui, China

 

1. Electrical & Structural Parameters

 

Category

Parameter

Value / Description

Identification​

Type / Model

60227 IEC 53 (RVV) — copper-core PVC-insulated PVC-sheathed flexible cord, 5-core

 

Common Name

Medium-duty PVC sheathed 5-core flexible power cable

 

Number of Cores × Nominal CSA

5 × 4 mm²​ (3 Phase + Neutral + Protective Earth, or 5 independent circuits)

Conductor​

Conductor Material

Annealed bare copper (Class 5 flexible, per GB/T 3956 / IEC 60228)

 

Conductor Construction (each core)

56 / 0.30 mm​ (56 fine strands of 0.30 mm diameter)

 

Conductor Shape

Circular, stranded flexible

 

Max. DC Resistance @ 20 °C (each core)

≤ 4.95 Ω/km​

Insulation​

Insulation Material

PVC/D type polyvinyl chloride compound

 

Insulation Nominal Thickness (each core)

0.8 mm​

 

Insulation Min. Thickness (thin point)

≥ 0.62 mm

 

Finished Core Outer Diameter (each)

≈ 3.7 ± 0.2 mm

Sheath​

Sheath Material

PVC/ST5 type polyvinyl chloride compound

 

Sheath Nominal Thickness

1.2 mm​

 

Sheath Min. Thickness (thin point)

≥ 0.96 mm

Dimensions​

Avg. Overall Diameter (round, 5-core bundled)

13.5 mm (lower) ~ 16.5 mm (upper)​

 

Reference Overall Diameter

≈ 14.8 mm (round, typical)

 

Approx. Weight

340 ~ 420 kg/km​ (typical ≈ 380 kg/km)

Electrical​

Rated Voltage (U₀/U)

300/500 V​ (AC)

 

Dielectric Withstand Test

2000 V AC, 5 min, no breakdown​

 

Min. Insulation Resistance @ 70 °C

≥ 0.009 MΩ·km​

 

Min. Insulation Resistance @ 20 °C

≥ 10 MΩ·km

 

Earth Continuity Resistance

≤ 4.95 Ω/km (same as phase conductors)

Temperature​

Max. Continuous Conductor Temp.

70 °C​

 

Short-Circuit Temp. (≤ 5 s)

160 °C

 

Min. Installation / Laying Temp.

0 °C​ (warm cable if below; some compounds allow −15 °C)

Mechanical​

Min. Bending Radius

6 × overall diameter​ (cable OD ≥ 12 mm) ≈ 81 ~ 99 mm

 

Flame Retardant

Passes GB/T 18380.12-2020 (IEC 60332-1), self-extinguishing

 

IP Level

IP44 (dust-protected + splash-resistant when properly terminated)

 

Physical Properties (PVC, before aging)

Tensile strength ≥ 12.5 N/mm²; elongation at break ≥ 150%

 

Aging (80±2 °C × 168 h)

Tensile / elongation change rate within ±20%

Color​

Core Colors (standard IEC, 3P+N+E)

Brown + Black + Grey + Blue + Green/Yellow

 

Alternative Core Colors

Red/Yellow/Blue/White/Green-Yellow; custom coding available

 

Sheath Color

Black (standard); Grey on request

Packing​

Standard Length

100 m / 200 m per drum (custom lengths available)

 

Drum Type

Wooden or plywood reel for 200 m; coil for 100 m

 

5x4mm2 5 Core Flexible Cable Transmission Control PVC Sheathed Stranded Copper Conductor

 

5x4mm2 5 Core Flexible Cable Transmission Control PVC Sheathed Stranded Copper Conductor

 

2. Current-Carrying Capacity Reference

 

Installation Condition

Reference Ampacity*

Notes

5-core, single cable in free air (25 °C ambient)

22 ~ 28 A​ (typical ≈ 26 A)

Per IEC 60227-5 tabulated value ≈ 26 A (single, 20 °C conductor)

5-core, bundled / in conduit (25 °C)

≈ 20 A

Apply ~23% derating for 5-core grouping in enclosed spaces

With ambient 30 °C

≈ 23.7 A

×0.91 temperature correction

With ambient 40 °C

≈ 21.3 A

×0.82 temperature correction

With ambient 50 °C

≈ 18.5 A

×0.71 temperature correction

Direct burial (single, in soil @ 20 °C)

≈ 29 A

Not standard RVV application; reference only if modified compound used

* Reference values for PVC-insulated copper conductor at 70 °C temp. class; actual ampacity must be corrected for ambient temperature, grouping/bundling, conduit fill, and local wiring regulations. Do not​ use the uncorrected free-air value for enclosed/conduit installations.

Derived electrical reference (5×4 mm², 30 m five-wire run — 3-phase 400 V or single-phase 220 V)

 

Quantity

Calculated Value

Interpretation

Voltage drop @ 26 A, 3-phase 400 V, 30 m (L-L loop)

≈ 10.4 V (2.6% of 400 V)​

Within 3% statutory limit for distribution

Voltage drop @ 26 A, single-phase 220 V, 30 m (L+N loop)

≈ 10.4 V (4.7% of 220 V)​

Within typical building wiring tolerance

Usable 3-phase power @ 26 A, 400 V

≈ 18.1 kVA (≈ 16.3 kW at pf=0.9)​

Suitable for 3-phase motors up to ~15 kW

Usable single-phase power @ 20 A, 220 V

≈ 4.4 kW​

Adequate for heavy socket groups, workshop feeds

PE conductor continuity check

≤ 4.95 Ω/km

Confirms very low earth-fault loop impedance for fast MCB/RCD trip

 

5x4mm2 5 Core Flexible Cable Transmission Control PVC Sheathed Stranded Copper Conductor

 

3. Product Performance Introduction

The RVV 5×4 mm²​ occupies a distinct position in the RVV family — it is the first size in the series where the conductor cross-section (4 mm²) and strand diameter (0.30 mm) step up to a heavier gauge, transforming the cable from a light-duty control wire into a medium-duty flexible power distribution cable. Each of the five cores uses a 56/0.30 mm Class 5 annealed copper stranding, delivering a conductor with substantially lower resistance (≤ 4.95 Ω/km vs. ≤ 26.0 Ω/km at 0.75 mm²) while retaining the flexibility needed for panel dress-in and equipment connection.

Why 5 cores at 4 mm² matters.​ This configuration is the standard 3-phase + Neutral + Earth (3P+N+E)​ layout for small-to-medium 3-phase equipment and distribution sub-feeds. Unlike running separate cables, a single 5-core assembly ensures all five conductors experience identical installation conditions — same bend radius, same pull tension, same thermal environment — which simplifies compliance with earth-loop impedance calculations and eliminates the risk of mixing phases with the wrong neutral or earth.

Thermal and mechanical scaling.​ Moving from 0.75 mm² to 4 mm² requires a thicker insulation wall (0.8 mm vs. 0.6 mm)​ and a substantially heavier sheath (1.2 mm vs. 0.9 mm)​ to contain the larger core bundle. The overall diameter jumps to 13.5–16.5 mm, and the minimum bend radius increases to 6× diameter (≈ 81–99 mm)​ — a direct consequence of the thicker conductors and the need to prevent inner-core buckling during bends. The cable weight increases proportionally to ~380 kg/km, requiring proper drum handling and mechanical assistance for long pulls.

Electrical robustness.​ At 4 mm², the ≤ 4.95 Ω/km resistance​ produces negligible I²R loss: at 26 A over 30 m (3-phase), the total power dissipated in the conductors is only ~40 W per core​ — easily dissipated by the PVC/D insulation without exceeding the 70 °C rating. The 2000 V AC / 5 min withstand​ and ≥ 0.009 MΩ·km @ 70 °C​ insulation resistance ensure long-term dielectric stability even under full-load cycling. Short-circuit withstand rises to 160 °C for 5 s, accommodating typical upstream MCB clearing times for a 4 mm² conductor.

Flexibility retained at larger gauge.​ Despite the heavier build, the 56-strand construction​ maintains a supple hand-feel that solid or Class 2 stranded conductors cannot match. This is critical for connections to vibrating equipment, movable machinery, or panels where periodic re-routing is expected over the installation's lifetime.

 

5x4mm2 5 Core Flexible Cable Transmission Control PVC Sheathed Stranded Copper Conductor

 

4. Specification Range

 

5x4mm2 5 Core Flexible Cable Transmission Control PVC Sheathed Stranded Copper Conductor

 

5. Applications & Scope of Use

Primary applications

  • 3-phase equipment feeds:​ Small-to-medium motors (2.2–15 kW), 3-phase compressors, CNC machines, conveyor drives, pumps with 3-phase input.

  • Distribution sub-boards:​ 3-phase + N + PE feed from main panel to sub-distribution boards in workshops, commercial kitchens, server rooms.

  • Industrial automation:​ Robotic cell power, servo drive feeds, VFD output cables (where VFD-rated cable is not mandated), PLC panel main incomers.

  • HVAC plant rooms:​ Chiller auxiliary circuits, AHU motor feeds, cooling tower pumps, heat pump 3-phase connections.

  • Event & broadcast:​ 3-phase power distro for stage boxes, dimmer racks, video walls, broadcast trucks (indoor/protected use).

  • Construction sites:​ Temporary 3-phase distribution boards, tower crane feeds, site-office power (protected routing).

  • Agricultural:​ 3-phase irrigation pumps, greenhouse climate-control panels, barn ventilation systems.

  • Marine / offshore (protected internal):​ Shipboard internal 3-phase distribution (non-exposed, inside enclosures).

Typical projects:​ industrial workshops and factories · commercial kitchens and laundries · data center auxiliary power · event production and staging · agricultural processing facilities · construction site temporary power · marine internal wiring (protected).

Use limitations:​ not for direct burial · not for prolonged outdoor UV exposure · not for fire-rated emergency circuits (use NH-RVV or WDZ-RVV) · not for VFD applications requiring symmetric grounding/shielding (use VFD-specific cable) · not for voltages above 500 V.


5x4mm2 5 Core Flexible Cable Transmission Control PVC Sheathed Stranded Copper Conductor

6. Installation & Handling

 

Aspect

Recommendation

Installation method

Conduit (min. 25 mm ID), cable tray (covered), trunking, inside distribution boards, equipment incomer

Drum handling

Use drum jack or forklift; never drag drum on its flange. Unreel, do not over-hand feed.

Phase identification

Standard: Brown (L1), Black (L2), Grey (L3), Blue (N), Green/Yellow (PE). Verify before termination.

Earth conductor termination

Connect PE first; verify continuity ≤ 4.95 Ω/km. Use crimp lug (4 mm² bootlace or ring terminal) — do not rely on screw-only.

Termination of fine strands

Mandatory:​ use bootlace ferrules (DIN 46228, 4 mm² / 12 mm barrel) or crimp lugs on all 5 cores. Strand splay at 26 A will cause hot-spot failure.

Pulling tension (max)

≤ 800 N axial pull (approx. 50 N/mm² × 16 mm² total copper CSA). Use cable sock or basket grip for long pulls.

Min. bend radius

≥ 6 × overall diameter (~81–99 mm). Use conduit sweeps, not sharp 90° elbows.

Low-temp handling

Below 0 °C, warm cable to ≥5 °C before bending/pulling. At 4 mm² the PVC sheath is noticeably stiffer than at 0.75 mm².

Conduit fill (5×4 mm²)

Cable cross-section ≈ 172 mm². In 25 mm conduit (ID ≈ 21 mm, area ≈ 346 mm²), single cable fill ≈ 50%. For multiple cables, use 32 mm or larger.

Support spacing

Cable tray: support every 400 mm. Vertical runs in conduit: secure every 600 mm to prevent slippage under weight.

Pre-energization check

Continuity all 5 cores + insulation resistance (≥1 MΩ at 1000 V DC megger) L1-E, L2-E, L3-E, N-E, L1-L2, L1-L3, L2-L3, L1-N, L2-N, L3-N.

Storage

Store drums upright on flat surface; protect from weather; do not stack drums more than 2 high.


5x4mm2 5 Core Flexible Cable Transmission Control PVC Sheathed Stranded Copper Conductor

7. Selection Guide (RVV 5-core family & alternatives)

 

If your project requires…

Recommended alternative

Smaller CSA (lighter, lower current)

RVV 5×1.5 mm²​ (30/0.25 mm, 0.8/1.0 mm insulation/sheath, ~180 kg/km)

Larger CSA (higher current)

RVV 5×6 mm²​ (84/0.30 mm, 0.8/1.2 mm, ~520 kg/km)

4-core only (no neutral)

RVV 4×4 mm²​ (3P+E)

3-core only

RVV 3×4 mm²​

Fire-resistant circuit integrity

NH-RVV 5×4 mm²​ (mica-tape fire barrier)

Low-smoke, zero-halogen (public buildings)

WDZ-RVV 5×4 mm²​ (LSZH sheath)

Shielded (EMC for VFD / sensitive equipment)

RVVP 5×4 mm²​ (foil + braid shield)

90 °C operating temperature

RVV-90 5×4 mm²​ (PVC/E + PVC/ST10)

Outdoor / UV / direct burial

Use YJV 5×4 mm²​ (XLPE insulated, PVC sheathed armored) or UV-rated jacketed type

VFD / inverter duty

Use symmetric grounded VFD cable (not standard RVV)


5x4mm2 5 Core Flexible Cable Transmission Control PVC Sheathed Stranded Copper Conductor

8. Quality Assurance

Every production batch is inspected per GB/T 5023.5-2008 / IEC 60227-5, covering: conductor resistance (4-wire Kelvin, all 5 cores), strand count & lay length verification, insulation & sheath thickness / concentricity (optical micrometer + slice gauge), high-voltage spark test (3000 V AC, 100% length), flame-retardancy sampling (GB/T 18380.12), PVC tensile/elongation and aging verification (80±2 °C × 168 h), plus dimensional and visual inspection including core color verification. Certificate of Compliance (CoC)​ and third-party test reports (e.g., CVC, CQC) are available on request, referenced to batch number and manufacturing date.