Stranded Copper Wire 5 Core Cable RVV 5x6.0mm² PVC Flexible 300/500V
Product Summary
Product Details
rvv multi core cable
,rvv 5 core flexible cable
,pvc multi core cable
Product Description
Stranded Copper Wire 5 Core Cable RVV 5x6.0mm² PVC Flexible 300/500V
Cable Designation & Meaning
|
Code |
Meaning |
|---|---|
|
RVV |
R = Flexible copper conductor (Class 5), V = PVC insulation, V = PVC sheath |
|
300/500 V |
Rated voltage U₀/U = 300/500 V; Uₘ = 500 V |
|
5×6.0 mm² |
Five flexible cores, each 6.0 mm² copper conductor (custom size) |
Construction: Five 6.0 mm² fine-stranded copper conductors, PVC insulation on each core, PVC outer sheath over twisted cores with filler. No metallic screen/armour as standard (can be added on request as RVVP).
Applicable Standards
- GB/T 5023.5-2008 / IEC 60227-5 — Polyvinyl chloride insulated flexible cables (cords) — Part 5: Flexible cables
- GB/T 3956-2008 / IEC 60228 — Conductors of insulated cables (Class 5 flexible)
- GB/T 18380.12 / IEC 60332-1-2 — Flame propagation test for a single vertical insulated wire
- GB/T 2951-2008 / IEC 60811 — Common test methods for insulating and sheathing materials

RVV 5×6.0 mm² — Cable Specification & Engineering Data
1. Product Overview & Rating Summary. RVV 5×6.0 is a five-core heavy-gauge flexible PVC-insulated PVC-sheathed cord rated at 300/500 V AC (50 Hz) and 70 °C conductor temperature, built around five equal 6.0 mm² annealed copper Class 5 flexible conductors — each PVC-insulated and collectively jacketed in a second PVC oversheath. Manufactured and type-tested to GB/T 5023.5 (60227 IEC 53) / IEC 60227-5, with flexible conductors per GB/T 3956. Finished diameter is about 25.6 mm and nominal mass about 640 kg/km (≈ 64 kg per 100 m), supplied on 100 m reels or cartons. With all five cores energised, the cord carries about 41 A in free air at 25 °C (engineering estimate) — the heaviest flexible cord in the RVV 300/50 V family, intended for industrial main-incoming leads, three-phase small-power motor supply and multi-conductor sub-main distribution where five conductors must share a single flexible jacket.
2. Layer-by-Layer Construction (Conductor to Jacket).
| Layer | Construction | Wall | Diameter |
|---|---|---|---|
| Conductor (Cu) ×5 | Annealed Cu, Class 5 flexible, 84 × 0.30 mm (1+6+12+18+24+23) each | — | ≈ 5.2 mm |
| Insulation (PVC) ×5 | PVC compound, PVC/C (TI1) | 1.00 mm | ≈ 7.2 mm per core |
| Core assembly | One central core + four outer cores cabled round; interstices filled by extrusion | — | ≈ 22.6 mm (derived) |
| Outer sheath (PVC) | PVC compound, PVC/ST5, black or custom | 1.50 mm | ≈ 25.6 mm (finished) |
3. Electrical Characteristics. Each 6.0 mm² conductor is held to a maximum DC resistance of 3.08 Ω/km at 20 °C, rising to around 3.90 Ω/km at the 70 °C operating point. Every length survives the routine 2.0 kV AC power-frequency proof held for five minutes. Finished-cable insulation resistance remains above 0.0070 MΩ·km at 70 °C, and typical figures include per-core capacitance ≈ 210 nF/km and 50 Hz AC impedance ≈ 3.08 Ω/km (R-dominant, reactance negligible at this small cross-section). With all five cores energised, reference loading is about 41 A in free air at 25 °C, and the loop voltage drop at 41 A is about 0.25 V per metre.
Insulation & Sheath Data
|
Property |
Value |
|---|---|
|
Insulation material |
PVC (Type TI2) |
|
Outer sheath material |
PVC (Type ST5) |
|
Long-term service temp. |
70 °C (continuous) |
|
Max. conductor temp. (normal) |
70 °C |
|
Short-circuit temp. (≤5 s) |
160 °C |
|
Emergency overload temp. |
100 °C (≤1 h) |
|
Test voltage AC (5 min) |
2.0 kV |
|
Dielectric strength |
≥ 20 kV/mm |
|
Volume resistivity @20 °C |
≥ 1×10¹³ Ω·cm |
|
Shield |
None as standard (RVVP available) |
Electrical Parameters
|
Parameter |
Value |
Note |
|---|---|---|
|
Rated voltage U₀/U |
300 / 500 V |
Uₘ = 500 V |
|
Test voltage AC (5 min) |
2.0 kV |
Routine (reference) |
|
Type-test voltage |
2.5 kV |
IEC 60227 reference |
|
DC resistance @20 °C (per core) |
≤ 3.30 Ω/km |
GB/T 3956 Class 5 max, 6 mm² |
|
AC resistance @70 °C (est.) |
≈ 4.21 Ω/km |
per core |
|
Current rating in air (single-phase, 30 °C, 2-core used) |
≈ 28 – 40 A |
per core |
|
Current rating (design, per core) |
≈ 34 A |
conservative, per GB/T 16895 extrapolation |
|
Current rating (5-core bundled, all loaded) |
≈ 18 – 28 A per core |
derated due to bundling |
|
Direct buried |
Not applicable |
light cord, not for direct burial |
|
Short-circuit current (1 s, Cu, 160 °C) |
≈ 0.60 kA (600 A) |
6 mm² reference |
|
Frequency |
50/60 Hz AC or DC |
— |
Reference values: 6 mm² flexible cord — typical current carrying capacity 28–40 A per core. For 3-phase+N+PE at 400 V, max balanced load ≈ 23.6 kW (34 A per phase). At 34 A, voltage drop ≈ 4.0 V/km per core (≈1.0% per 100 m at 400 V line-to-line).
4. Thermal Response & Flame Behaviour. PVC insulation sustains a 70 °C continuous conductor temperature. The cord is rated for service ambients between −15 and +70 °C, must not be uncoiled below 0 °C without pre-conditioning, and uses 25 °C as the reference ambient for ampacity. Flame behaviour meets the single-cable vertical test GB/T 18380.12 (IEC 60332-1), meaning the cord self-extinguishes when the flame source is removed. Because both insulation and sheath are halogenated PVC, the cord emits smoke and hydrogen chloride in a fire; low-smoke zero-halogen projects must specify an LSZH variant.
Temperature Characteristics
|
Property |
Value |
|---|---|
|
Max. conductor operating temp. |
70 °C (continuous) |
|
Max. short-circuit temp. (≤5 s) |
160 °C |
|
Emergency overload temp. |
100 °C (≤1 h) |
|
Min. installation ambient temp. |
−15 °C |
|
Service ambient range |
−15 °C to +70 °C |
|
Flexing temp. range |
−5 °C to +70 °C |
Fire Performance (RVV 5×6 mm² custom)
|
Property |
Value / Requirement |
|---|---|
|
Flame retardant |
Single flame test (GB/T 18380.12) |
|
Halogen content |
Contains Cl (PVC), produces HCl |
|
Smoke density |
Heavy dark smoke |
|
Corrosivity |
Corrosive HCl gas |
5. Installation Practice & Handling. Bends must not fall below 6 times the actual outer diameter — about 154 mm for this size. Termination requires stripping 20–25 mm and always using a ferrule on the flexible Class 5 strands to prevent wire fraying. Reels held below 0 °C in storage must be warmed indoors before uncoiling; pulling tension should stay within 450 N, and the cord must never be used as a pulling rope. The 41 A reference requires derating whenever ambient temperature or bundling deviates from reference conditions. This cord is not for direct burial, outdoor UV exposure or continuous repetitive flexing — for those duties choose an armoured cable, a UV-stabilised jacket or a continuous-flex (trunking) cable respectively.
Mechanical & Installation Parameters
|
Parameter |
Value |
Remarks |
|---|---|---|
|
Minimum bending radius |
≥ 6 × OD → ≈ 107 mm at Ø17.8 mm |
flexible cable |
|
Max. pulling tension |
90 N per core (6.0 mm² × 15 N/mm²) |
Cu conductor limit |
|
Direct burial |
Not recommended (use buried conduit) |
— |
|
Surface mounting |
Cable tray, conduit, trunking, cable clips |
— |
|
Conduit ID |
≥ 50 mm |
— |
|
Fixing |
heavy-duty cable ties, clips |
— |
|
Impact resistance |
Low (light-duty) |
— |
|
Water resistance |
Limited (PVC sheath) |
— |
|
UV resistance |
Poor (PVC degrades outdoors, use UV-resistant or conduit) |
— |
|
Flex life |
Excellent (Class 5 fine-stranded) |
flexible / portable |
|
Termination note |
Compression lugs required (ferrule recommended for control use) |
— |
6. Typical Service Applications. This five-core 6.0 mm² cord is the heavy multi-conductor lead for industrial main-incoming and three-phase small-power circuits: small three-phase motor feeds up to about 7.5 kW (pump, compressor, fan, conveyor), commercial VRF and multi-split air-conditioner main leads up to about 10 kW, electric cooker and oven supply leads up to about 9 kW, electric storage-heater and boiler main feeds, workshop and garage distribution board main incomings up to 40 A, machinery control panel main supply leads, welding-machine and battery-charger heavy-duty supply cords, commercial kitchen combi-oven and extraction main feeds, agricultural irrigation and greenhouse three-phase control power, EV charger main power and control wiring up to 32 A, stage and exhibition temporary three-phase distribution up to 40 A, light industrial conveyor main supply, laboratory instrument and bench main supply, and light commercial multi-conductor main feeds. Approved installation methods include fixed wiring inside equipment, cable trunking and indoor ducting in dry locations, both indoors and in covered sheltered spaces.

7. Testing & Quality Assurance Regime. Routine tests on every length include conductor DC resistance verification (≤ 3.08 Ω/km) at 20 °C, the 2.0 kV AC / 5 min withstand, insulation resistance ≥ 0.0070 MΩ·km at 70 °C, conductor continuity across all five cores, and dimensional inspection covering insulation ≥ 1.00 mm, sheath ≥ 1.50 mm and overall diameter ≈ 25.6 mm. Sample and type tests comprise PVC insulation and sheath tensile strength (≥ 10 MPa) with elongation (≥ 100 % insulation / ≥ 125 % sheath), PVC heat deformation at 80 °C, PVC shrinkage at 150 °C, the single-cable vertical flame test, bending and cold-bend tests at −15 °C, and the voltage test after flexing. A factory test certificate accompanies each reel.
Cable Parameters
| RVV 5×6.0 mm² — Full Parameter Sheet | ||||
| Copper-core PVC-insulated PVC-sheathed flexible cord · 300/500 V · GB/T 5023.5 / IEC 60227-5 (60227 IEC 53) · 5-core round arrangement · finished Ø ≈ 25.6 mm · ≈ 640 kg/km — cross-referenced industry sample data | ||||
| Section | Parameter | Value | Unit | Remarks / Standard |
| 01 · Identification | ||||
| Cable type | RVV | — | Copper conductor, PVC insulation, PVC sheath, flexible round cord (60227 IEC 53) | |
| Rated voltage (U0/U) | 300/500 | V | AC 50 Hz; maximum system voltage Um = 500 V | |
| Number of cores | 5 | — | Five-core round flexible cord | |
| Nominal cross-sectional area | 6.0 × 5 | mm² | Per conductor | |
| Conductor material | Annealed copper (Cu) | — | Class 5 flexible stranded per GB/T 3956 / IEC 60228 | |
| Insulation material | PVC, PVC/C (TI1) compound | — | 70 °C rated | |
| Sheath material | PVC, PVC/ST5 compound | — | Black or custom colour | |
| Standard reference | GB/T 5023.5 / IEC 60227-5 | — | 60227 IEC 53 RVV flexible cords | |
| 02 · Conductor | ||||
| Stranding (per core) | 84 × 0.30 mm | — | Class 5 flexible lay-up (1+6+12+18+24+23) | |
| Conductor diameter | ≈ 5.2 | mm | Strand-lay diameter (est.) | |
| DC resistance @ 20 °C | ≤ 3.08 | Ω/km | Maximum per GB/T 3956 Class 5 | |
| DC resistance @ 70 °C | ≈ 3.90 | Ω/km | Temperature-corrected (est.) | |
| Copper mass (all cores) | ≈ 266.7 | kg/km | 5 × 6.0 × 8.89 g/cm³ | |
| Conductor flexibility | Class 5 (flexible) | — | Suitable for repeated bending / appliance leads | |
| 03 · Insulation | ||||
| Insulation thickness (per core) | 1 | mm | GB/T 5023.5 specified for 6.0 mm² | |
| Core Ø over insulation | ≈ 7.2 | mm | 5.2 + 2 × 1.0 | |
| Insulation material | PVC, PVC/C (TI1) | — | Thermoplastic, 70 °C rated | |
| Insulation resistance @ 70 °C | ≥ 0.0070 | MΩ·km | Finished cable, minimum | |
| PVC insulation tensile strength | ≥ 10 | MPa | Type test | |
| PVC insulation elongation at break | ≥ 100 | % | Type test | |
| Insulation colour | Black / red / blue / yellow / yellow-green | — | Standard 5-core colour-coding; custom available | |
| 04 · Assembly | ||||
| Core arrangement | 1 central core + 4 outer cores cabled round | — | Round 5-core lay-up | |
| Filler | None (interstices filled by extrusion) | — | Compact round shape | |
| Binder tape | Not required | — | Sheath extrudes over the core bundle | |
| Assembled core Ø | ≈ 22.6 | mm | Derived: 25.6 − 2 × 1.5 sheath | |
| Lay-up direction | Right-hand (S) | — | Standard convention | |
| 05 · Sheath | ||||
| Sheath material | PVC, PVC/ST5 compound | — | Black or custom colour | |
| Sheath thickness | 1.5 | mm | Per GB/T 5023.5 for ≈ 22.6 mm assembled Ø | |
| Overall finished diameter | ≈ 25.6 | mm | Cross-referenced industry 5-core sample | |
| Approximate cable mass | ≈ 640 | kg/km | Cross-referenced industry data | |
| PVC sheath tensile strength | ≥ 10 | MPa | Type test | |
| PVC sheath elongation at break | ≥ 125 | % | Type test | |
| Mass per 100 m | ≈ 64.0 | kg/100 m | For reel / carton loading estimation | |
| 06 · Electrical | ||||
| Rated voltage U0/U | 300/500 | V | AC 50 Hz | |
| Maximum system voltage Um | 500 | V | — | |
| DC resistance @ 20 °C | ≤ 3.08 | Ω/km | GB/T 3956 Class 5 | |
| AC impedance @ 50 Hz | ≈ 3.08 | Ω/km | R-dominant; negligible reactance | |
| Capacitance (typical) | ≈ 210 | nF/km | Per core (est.) | |
| Insulation resistance @ 70 °C | ≥ 0.0070 | MΩ·km | Finished cable, minimum | |
| Routine test voltage | 2.0 kV AC / 5 min | — | Power-frequency withstand, no breakdown | |
| Air ampacity @ 25 °C | ≈ 41 | A | Five cores loaded, Cu (est.) | |
| Voltage drop @ 41 A | ≈ 0.25 | V/m | 2 × 3.08 × 41 / 1000 (est.) | |
| 07 · Thermal | ||||
| Max continuous conductor temp. | 70 | °C | PVC rated | |
| Max ambient temp. (service) | +70 | °C | Conductor-limited | |
| Min ambient temp. (service) | −15 | °C | PVC flexibility limit | |
| Min laying temperature | 0 | °C | Warm reels below 0 °C | |
| Thermal coefficient of resistance (Cu) | 0.00393 | 1/°C | At 20 °C reference | |
| 08 · Flame (flammability) | ||||
| Flame-retardant behaviour | Non-flame-spreading | — | Per GB/T 18380.12 (IEC 60332-1) | |
| Halogen content | Halogen-bearing (PVC) | — | Emits HCl under fire | |
| Smoke emission | Emits smoke under fire | — | PVC insulation and sheath | |
| Special LSZH version | Not standard | — | Specify LSZH variant for public areas | |
| 09 · Installation | ||||
| Min bending radius (flexible cord) | ≥ 6 × OD ≈ 154 | mm | OD = actual finished diameter | |
| Max pulling tension | ≤ 450 | N | ≈ 15 N/mm² of total copper area (est.) | |
| Laying methods | Fixed wiring inside appliances, ducting, trunking | — | Indoor dry locations | |
| Outdoor / burial note | Not for direct burial or outdoor UV exposure | — | Use UV-stabilised or armoured cable if required | |
| Termination | Solder, crimp ferrule or screw terminal | — | Strip 20–25 mm for flexible Class 5 conductors | |
| Flexing / flexible use | Suitable for occasional movement | — | Not for continuous repetitive flexing (use H05VV5-F if so) | |
| 10 · Packing | ||||
| Standard supply length | 100 | m/reel or carton | Custom lengths available | |
| Reel / packing type | Plastic reel or carton | — | Sealed until installation | |
| Surface marking | Type, voltage, supplier, year, metre marks | — | Per GB/T 6995 | |
| Storage conditions | Dry, covered, −15 to +40 °C | — | Away from sunlight, moisture, oils, sharp objects | |
| Transport | Reels secured against rolling | — | Do not drag cable over rough ground | |
Cable Test Parameters
| Test Parameters — RVV 5×6.0 mm² | ||||
| No. | Test Item | Test Condition / Method | Requirement | Type |
| 1 | Conductor DC resistance | GB/T 3048.4, 20 °C | ≤ 3.08 Ω/km per conductor | Routine |
| 2 | Power-frequency withstand | 2.0 kV AC, 5 min | No breakdown | Routine |
| 3 | Insulation resistance @ 70 °C | GB/T 3048.5, 70 °C | ≥ 0.0070 MΩ·km | Routine |
| 4 | Conductor continuity | Visual + electrical | All five cores continuous | Routine |
| 5 | Dimensional check | Micrometer | Insulation ≥ 1.0 mm; sheath ≥ 1.5 mm; OD ≈ 25.6 mm | Routine |
| 6 | PVC insulation tensile & elongation | GB/T 2951.11 | Tensile ≥ 10 MPa; elongation ≥ 100 % | Type |
| 7 | PVC sheath tensile & elongation | GB/T 2951.11 | Tensile ≥ 10 MPa; elongation ≥ 125 % | Type |
| 8 | PVC heat deformation | 80 °C, 4 h, load | Deformation ≤ 50 % | Type |
| 9 | PVC shrinkage test | 150 °C, 1 h | Shrinkage ≤ 4 % | Type |
| 10 | Single-cable vertical flame | GB/T 18380.12 | Self-extinguishing; char ≤ 50 mm above burner | Type |
| 11 | Bending / flexing test | ≥ 6 × OD mandrel | No crack in insulation or sheath | Type |
| 12 | Cold bend test | −15 °C, 4 h | No cracking after mandrel bend | Type |
| 13 | Ozone / weathering (outdoor variant) | As required | Per customer specification | Optional |
| 14 | Voltage test after bending | 2.0 kV AC, 5 min | No breakdown after flexing | Type |
| 15 | Marking legibility | Visual + rubbing | Type/voltage/supplier/metre marks legible | Routine |
| 16 | Core identification | Visual + continuity | Correct colour-coded conductors identified | Routine |
Cable Cross Section Structure

| RVV 5×6.0 mm² — Cross-Section Construction Diagram (Schematic) | |||||
| Layered 5-core flexible build-up from fine copper strands to PVC jacket · nominal dimensions per GB/T 5023.5 / IEC 60227-5 · finished Ø ≈ 25.6 mm per cross-referenced industry sample | |||||
| No. | Layer | Material / Construction | Nominal Thickness (mm) | Diameter (mm) | Function / Remarks |
| 1 | Conductor (Cu) × 5 | Annealed copper, Class 5 flexible stranded — 84 wires of 0.30 mm per core (1+6+12+18+24+23 layout), nominal area 6.0 mm² each | — | ≈ 5.2 (Ø each conductor) | Flexible power conductors; DC resistance capped at 3.08 Ω/km at 20 °C |
| 2 | Insulation (PVC) × 5 | PVC compound, PVC/C (TI1) | 1 | ≈ 7.2 (Ø each insulated core) | Electrical isolation; 70 °C continuous rating; withstands 2.0 kV for 5 min |
| 3 | Core assembly | One central core + four outer cores cabled round; interstices filled by sheath extrusion | — | ≈ 22.6 (Ø over assembled cores) | Round 5-core lay-up; derived from finished Ø 25.6 − 2×1.5 sheath |
| 4 | Outer sheath (PVC) | PVC compound, PVC/ST5, black or custom | 1.5 | ≈ 25.6 (Ø finished cable) | Mechanical protection and abrasion resistance; non-flame-spreading per GB/T 18380.12 |
| Key Dimensions & Properties (expanded) | |||||
| Finished cable diameter | ≈ 25.6 | mm | Cross-referenced industry 5-core sample | ||
| Approximate cable mass | ≈ 640 | kg/km | Cu build-up (cross-referenced industry data) | ||
| Nominal voltage rating | 300/500 | V | AC 50 Hz; maximum system voltage Um = 500 V | ||
| Conductor temperature limit | 70 | °C | Continuous service | ||
| Minimum bend radius (flexible) | ≥ 6 × OD ≈ 154 | mm | OD = actual finished cable diameter | ||
| Flame behaviour | Non-flame-spreading | — | Per GB/T 18380.12 | ||
| Conductor DC resistance | ≤ 3.08 | Ω/km | At 20 °C, per GB/T 3956 Class 5 | ||
| Insulation resistance @ 70 °C | ≥ 0.0070 | MΩ·km | Finished cable, minimum | ||
| Routine test voltage | 2.0 kV AC / 5 min | — | Power-frequency withstand | ||
| AC impedance @ 50 Hz | ≈ 3.08 | Ω/km | R-dominant (est.) | ||
| Capacitance (typical) | ≈ 210 | nF/km | Per core (est.) | ||
| Air ampacity @ 25 °C | ≈ 41 | A | Five cores loaded, Cu (est.) | ||
| Voltage drop @ 41 A | ≈ 0.25 | V/m | Loop drop (est.) | ||
| Maximum pulling tension | ≤ 450 | N | ≈ 15 N/mm² of total copper area (est.) | ||
| Mass per 100 m | ≈ 64.0 | kg/100 m | For reel / carton loading | ||
| Schematic — not to exact scale. Finished Ø ≈ 25.6 mm and weight ≈ 640 kg/km from cross-referenced industry samples; conductor/insulation diameters calculated from GB/T 3956 and GB/T 5023.5; ampacity 41 A is an engineering estimate for 5-core flexible cords. Values marked (est.) require confirmation against the factory test certificate. | |||||
Cable Construction Description
| Construction Description — RVV 5×6.0 mm² | |||
| Layer-by-layer build-up narrative, conductor through outer jacket · per GB/T 5023.5 & IEC 60227-5 · CU / PVC / PVC · 300/500 V class · 5-core round arrangement · finished Ø ≈ 25.6 mm (cross-referenced industry sample) | |||
| 1. Product Identity & Ratings | |||
| RVV 5×6.0 is a five-core heavy-gauge flexible PVC-insulated PVC-sheathed cord rated at 300/500 V AC (50 Hz) and 70 °C conductor temperature, built around five equal 6.0 mm² annealed copper Class 5 flexible conductors — each PVC-insulated and collectively jacketed in a second PVC oversheath. Manufactured and type-tested to GB/T 5023.5 (60227 IEC 53) / IEC 60227-5, with flexible conductors per GB/T 3956. Finished diameter is about 25.6 mm and nominal mass about 640 kg/km (≈ 64 kg per 100 m), supplied on 100 m reels or cartons. With all five cores energised, the cord carries about 41 A in free air at 25 °C (engineering estimate) — the heaviest flexible cord in the RVV 300/50 V family, intended for industrial main-incoming leads, three-phase small-power motor supply and multi-conductor sub-main distribution where five conductors must share a single flexible jacket. | |||
| 2. Flexible Copper Conductors | |||
| Each 6.0 mm² conductor is stranded from eighty-four 0.30 mm annealed wires in the 1+6+12+18+24+23 arrangement — the Class 5 flexible standard at this cross-section — giving a strand-lay diameter of about 5.2 mm and a DC resistance ceiling of 3.08 Ω/km at 20 °C (about 3.90 Ω/km at the 70 °C operating point). The dense fine-wire bundle retains acceptable flexibility despite the heavy cross-section. Copper mass is about 53.33 kg/km per core, 266.7 kg/km in total. | |||
| 3. PVC Insulation | |||
| PVC is extruded at 1.00 mm onto each 6.0 mm² conductor, producing approximately 7.2 mm per insulated core. The insulation is rated for 70 °C continuous duty, passes the routine 2.0 kV AC five-minute voltage proof, and maintains insulation resistance above 0.0070 MΩ·km at 70 °C. Standard colours are black, red, blue, yellow and yellow-green (five distinct circuits), and custom colour combinations can be specified to order. | |||
| 4. Cabling & PVC Outer Jacket | |||
| After insulation, one core is placed at the centre and the remaining four are cabled around it in a round lay-up; interstices are filled by the extruded sheath itself, forming a compact round bundle of about 22.6 mm diameter. A 1.50 mm layer of PVC (ST5 compound) is then extruded over the core bundle to the ≈ 25.6 mm finish. The jacket provides abrasion resistance and mechanical protection, and the whole cord meets the single-cable vertical flame test GB/T 18380.12. Because both insulation and sheath are halogenated PVC, the cord emits smoke and HCl in a fire; for public or confined spaces, specify a low-smoke zero-halogen variant. | |||
| 5. Site Handling & Operational Notes | |||
| • Observe the 6 × OD minimum bending radius (≈ 154 mm). • Strip 20–25 mm for termination and always use a ferrule on the flexible Class 5 strands to prevent wire fraying. • Service ambient spans −15 to +70 °C; warm reels indoors before pulling below 0 °C. • The 41 A reference requires derating for ambient temperature and bundling. • Maximum pulling tension ≤ 450 N; do not use the cord as a pulling rope. • Not for direct burial, outdoor UV exposure or continuous repetitive flexing. • Use reels with flanges suited to the ≈ 25.6 mm OD. |
8. Standards & Conformity. Design and production are governed by GB/T 5023.5 and IEC 60227-5 for 300/500 V flexible cords (60227 IEC 53). Conductors satisfy GB/T 3956 / IEC 60228 Class 5 — the 6.0 mm² conductor as 84 wires of 0.30 mm (R ≤ 3.08 Ω/km). Flame behaviour is proven by GB/T 18380.12. General test methods follow GB 5023.1 / GB 5023.3, while surface marking complies with GB/T 6995. Cables can also be supplied to IEC, BS, DIN, UL or VDE requirements on request. Because the PVC jacket contains halogen, tunnels, metro systems, hospitals and other confined public areas call for an LSZH variant.

9. Packaging, Storage & Logistics. Standard delivery is 100 m per reel or carton, with bespoke cut lengths available on request. Each reel carries type, voltage, supplier identity, production year and sequential metre marking per GB/T 6995. Storage should be in dry, covered premises at −15 to +40 °C, shielded from direct sunlight, moisture, oils and sharp objects; reels remain sealed until installation. In cold conditions, condition reels indoors to ≥ 0 °C before uncoiling. During transit, reels must be secured against rolling and impact, and the cord must never be dragged across abrasive ground or sharp edges.
10. Procurement Specification. State "RVV 300/500 V 5×6.0" together with the required length or reel arrangement, insulation colour combination and marking preferences. Specify the sheath colour (black is standard) and the five-core colour-coding (black, red, blue, yellow, yellow-green as standard). Always request the factory test certificate to confirm the actual diameter (≈ 25.6 mm), weight (≈ 640 kg/km) and conductor resistance (≤ 3.08 Ω/km) for the production batch. Where low-smoke zero-halogen or continuous-flex construction is needed, order the LSZH or H05VV5-F variant respectively.
11. Cable Industry FAQ.
- Q1: When should I move up from 4.0 mm² to 6.0 mm²? Move to 6.0 mm² when the circuit carries up to about 41 A (vs 32 A for 4.0), when powering three-phase motors up to 7.5 kW, VRF air-conditioners up to 10 kW, or 9 kW cookers, or when voltage drop over long 40–60 m runs becomes marginal on 4.0 mm². It is the standard cross-section for 40 A main incomings and three-phase small-power leads.
- Q2: Can this cord power a 7.5 kW three-phase motor? Yes — 41 A at 230 V supports about 9.4 kW single-phase, and on a 400 V three-phase basis the 6.0 mm² conductors comfortably carry a 7.5 kW motor (about 15 A per phase). Always protect with a 40 A MCB or motor-protective circuit-breaker and confirm the locked-rotor current.
- Q3: Why five cores at 6.0 mm² instead of four? Five cores allow three phases + neutral + earth for balanced or unbalanced three-phase loads, plus additional spare or control cores for thermostat, sensor or communication wiring — essential for VRF heat-pump and three-phase appliance interconnects.
- Q4: What does Class 5 flexible conductor mean at 6.0 mm²? Class 5 (GB/T 3956) uses 84 thin wires of 0.30 mm rather than a single solid 2.76 mm wire. This keeps the heavy cord reasonably flexible and bend-endurable despite the large cross-section — required for appliance leads and machine interconnects that are flexed during installation or servicing.
- Q5: Why is 6.0 mm² rated at about 41 A while power cables carry far more? Cross-section directly determines current-carrying capacity. 6.0 mm² is near the upper end of the RVV 300/50 V flexible cord range; 10 mm² already carries about 57 A and 16 mm² about 76 A. Oversizing unnecessarily increases cost, diameter and copper weight.
- Q6: Can RVV be used outdoors? Not in its standard form: the PVC jacket is not UV-stabilised and will degrade under prolonged sunlight. For outdoor use specify a UV-stabilised jacket or an armoured cable. For burial, use a steel-tape armoured power cable.
- Q7: What is the difference between flexible (Class 5) and solid (Class 1) conductors? Solid Class 1 conductors (single wire) are cheap and rigid, suitable for fixed wall wiring. Flexible Class 5 conductors (many fine wires) bend easily and resist fatigue from repeated movement — essential for appliance leads, patch cords and control cabinet wiring.
- Q8: Why can PVC only run at 70 °C while XLPE runs at 90 °C? PVC is a thermoplastic that softens and deforms at elevated temperature; XLPE is cross-linked into a thermoset network that retains its shape up to 90 °C. This is why RVV (PVC) is limited to 70 °C and YJV (XLPE) to 90 °C.
- Q9: Why does finished diameter vary between manufacturers for the same nominal size? Standards set minimum insulation and sheath thicknesses plus electrical performance, but not a precise overall diameter. Stranding compaction, filler design and sheath tolerance differ between plants — published 5×6.0 figures cluster around 25.6 mm — so the actual measured diameter must be used when sizing glands and clips.
- Q10: Which tests confirm acceptability on delivery and before energisation? At delivery, verify the factory test certificate (conductor resistance ≤ 3.08 Ω/km, 2.0 kV/5 min withstand, dimensions ≈ 25.6 mm), jacket legibility and reel integrity. After installation, complete an insulation-resistance test plus a 2.0 kV AC / 5 min withstand, then confirm all five conductors identified correctly before energising.
- Q11: What service life can be expected? When installed and operated within the stated temperature and voltage limits, PVC flexible cords are designed for a service life of around 10–15 years in dry indoor conditions; sustained overload, repeated flexing beyond the 6 × OD minimum radius, ultraviolet exposure, or operation above 70 °C will materially shorten that life.