RVVP 2x1.5mm² Shielded Control Panel Wire Braided Copper Relay Circuit EMI Protection 300/500V

RVVP 2x1.5mm² Shielded Control Panel Wire Braided Copper Relay Circuit EMI Protection 300/500V

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
RVVP 2x1.5mm²

Trading Properties

moq
1 Meter
payment method
L/C,T/T
supply capacity
100000 meters per month

Product Summary

RVVP 2x1.5mm² Shielded Control Panel Wire Braided Copper Relay Circuit EMI Protection 300/500V Cable Designation & Meaning Code Meaning R Flexible conductor (Class 5 fine-stranded) V PVC insulation V PVC sheath P Copper wire shield (braid or braid+tape) 2×1.5 mm² Two cores, each 1.5 mm² copper ...

Product Details

Conductor (×2):
Copper, Class 5 Fine-stranded Flexible, Nominal 30×∅0.25 Mm (1.5 Mm² Per Core), Conductor Ø ≈ 1.7–2.0 Mm
Insulation (per core):
PVC (polyvinyl Chloride)​ Compound, Nominal Thickness 0.7 Mm, Colour: Red​ (signal/power +) And Black​ (signal/power −) Or As Specified
Lay-up:
Two Cores Twisted Together With PVC Filler To Form Round Core Bundle
Shield:
Copper Wire Braid, Coverage 80% (typical), Or Copper Braid + Aluminium Polyester Tape (optional)
Outer sheath:
PVC (polyvinyl Chloride)​ Compound, Nominal Thickness 1.0 Mm (typical), Colour: Grey​ Or Black​ (round Profile)
Conductor nominal area:
1.5 Mm² (Cu)
Number of cores:
2
Conductor material:
Copper (Cu)
Conductor class:
Class 5 Fine-stranded Flexible
Conductor construction:
32×∅0.25 Mm (typical)
Conductor diameter (approx.):
1.7–2.0 Mm
Insulation thickness (per core):
0.7 Mm
Shield coverage:
80%
Outer sheath thickness:
1.0 Mm
Overall cable diameter:
7.5 – 9.0 Mm
Design outer diameter:
≈ 8.2 Mm
Approx. weight:
0.090 – 0.115 Kg/m (90–115 Kg/km)
Design weight:
≈ 102 Kg/km
Cable shape:
Round

Product Description

RVVP 2x1.5mm² Shielded Control Panel Wire Braided Copper Relay Circuit EMI Protection 300/500V

Cable Designation & Meaning

Code

Meaning

R

Flexible conductor (Class 5 fine-stranded)

V

PVC insulation

V

PVC sheath

P

Copper wire shield (braid or braid+tape)

2×1.5 mm²

Two cores, each 1.5 mm² copper


Construction: Two fine-stranded flexible copper conductors, each PVC insulated, laid up with fillers to form a round core assembly, wrapped with copper braid shield (typically 85%–90% coverage), and extruded with a common round PVC outer sheath.

Applicable Standards

  • JB/T 8734.5-2016 — Rated voltages up to and including 450/750 V PVC insulated cables and cords for fixed wiring and flexible applications — Part 5: Shielded flexible cables
  • GB/T 5023.5-2008 / IEC 60227-5 — Polyvinyl chloride insulated cables — Flexible cables (cords)
  • GB/T 3956 / IEC 60228 — Conductors (Class 5 flexible copper)
  • GB/T 2951 / IEC 60811 — Insulating and sheathing materials — Common test methods
  • GB/T 18380 / IEC 60332-1 — Flame retardant (single cable, passes)
  • GB/T 5441 — Communication cable test methods (shielding effectiveness reference)

RVVP 2x1.5mm² Shielded Control Panel Wire Braided Copper Relay Circuit EMI Protection 300/500V


RVVP 2×1.5 mm² — Shielded Flexible PVC Control Cable — Specification & Engineering Data 

1. Overview & Ratings. RVVP 2×1.5 is a shielded flexible PVC control cable rated 300/500 V, 70 °C continuous. Built per GB/T 9330 / IEC 60227. Two 1.5 mm² fine-stranded copper conductors (~30×0.25 mm) enclosed in a copper wire braid shield (≥ 80% coverage) and PVC outer sheath. Designed for medium industrial control circuits. Finished OD ≈ 7.6 mm, ≈ 115 kg/km, 100 m coils.


2. Construction Stack (Conductor → Outer).

Layer Build Wall Diameter
Conductors (×2) Fine-stranded annealed Cu, Class 5, 2×1.5 mm² — ≈ 1.6 mm each
PVC insulation Polyvinyl chloride, per core ≈ 0.7 mm ≈ 3.0 mm each
Copper braid shield Tinned copper wire braid, ≥ 80% coverage ≈ 0.5 mm ≈ 6.5 mm
PVC outer sheath PVC, dark green ≈ 1.2 mm ≈ 7.6 mm (finished)


3. Electrical Characteristics. DC resistance ≤ 13.3 Ω/km at 20 °C (flexible Cu 1.5 mm²); test voltage 2.0 kV AC / 5 min; insulation resistance ≥ 20 MΩ·km. Shield resistance ≤ 20 Ω/km. Nominal ampacity ≈ 13 A (medium control). Mutual capacitance ≤ 200 pF/m.

Insulation & Sheath Data

Property

Value

Insulation material

PVC (polyvinyl chloride), Type TI1/TI2

Outer sheath material

PVC (polyvinyl chloride), Type TM1/TM2

Long-term service temp.

70 °C (continuous, both insulation & sheath)

Short-circuit temp. (≤5 s)

160 °C (Cu conductor limit for PVC)

Emergency overload temp.

105 °C (short term)

Test voltage AC (5 min)

2.0 kV (routine test, 300/500 V class)

Dielectric strength

≥ 15 kV/mm (room temp.)

Shielding effectiveness

≥ 60 dB at 30 MHz – 100 MHz (typical copper braid)

Transfer impedance

≤ 100 mΩ/m at 10 MHz (typical)


Electrical Parameters


Parameter

Value

Note

Rated voltage U₀/U

300 / 500 V

JB/T 8734.5 / GB/T 5023.5

Max. system voltage

500 V AC

—

Test voltage AC (5 min)

2.0 kV

Routine test (core-to-core, core-to-shield)

DC resistance @20 °C

≤ 13.3 Ω/km

GB/T 3956 Class 5 Cu max, 1.5 mm²

AC resistance @70 °C (est.)

≈ 16.9 Ω/km

per core

Current rating in air (30 °C)

13 A​

2-core, open air, reference value

Current rating in tray (30 °C)

11 A​

bundled with other cables

Current rating in conduit (30 °C)

10 A​

enclosed

Short-circuit current (1 s, Cu, 160 °C)

≈ 0.17 kA (170 A)

1.5 mm² Cu

Capacitance (core-to-core, approx.)

≈ 120 pF/m

PVC insulation

Capacitance (core-to-shield, approx.)

≈ 175 pF/m

collective shield

Inductive reactance (approx.)

≈ 0.08 Ω/km

at 50 Hz

Frequency

50/60 Hz AC (signal up to ~10 MHz)

—


Reference values: 2×1.5 mm² at 10–13 A, single-phase 230 V → max load ≈ 2.3–3.0 kW. Suitable for signal + moderate power​ applications (control signals plus actuator/relay coil currents up to ~3 A per core).

Reference values: 2×1.0 mm² at 7–10 A, single-phase 230 V → max load ≈ 1.6–2.3 kW. Primarily intended for signal and low-to-medium 



4. Thermal & Mechanical. 70 °C continuous; 160 °C short-circuit (≤ 5 s); ambient −15~+70 °C. Bend ≥ 6 × OD ≈ 46 mm. Handles up to ~13 A for PLC I/O and relay circuits.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

70 °C (continuous)

Max. short-circuit temp. (≤5 s)

160 °C (Cu conductor, PVC limit)

Emergency overload temp.

105 °C (not recommended for continuous)

Min. installation ambient temp.

0 °C (PVC); below 0 °C pre-heating required

Service ambient range

−15 °C to +70 °C (PVC insulation & sheath)

Flexing temp. range

+5 °C to +70 °C (recommended for repeated bending)

Fire survival

Standard (flame retardant single cable)


Fire Performance (RVVP — Standard)

Property

Value / Requirement

Flame retardant

IEC 60332-1 (single cable, passes)

Halogen content

Contains halogen (PVC insulation & sheath)

Smoke density

Standard (non-low-smoke)

Corrosivity

Corrosive (PVC)

Fire survival (circuit integrity)

Not applicable (standard version)

EMI shielding

Yes​ (copper braid, 85%–90% coverage)


RVVP 2x1.5mm² Shielded Control Panel Wire Braided Copper Relay Circuit EMI Protection 300/500V

Shielding Performance

Parameter

Value

Note

Shield type

Copper wire braid (bare or tinned)

—

Coverage

85%–90% (typical)

>90% available on request

Optional

Copper braid + aluminium polyester tape (dual shield)

for high EMI environments

Drain wire

Not required (braid is continuous)

—

Shielding effectiveness

≥ 60 dB @ 30–100 MHz

typical braid

Transfer impedance

≤ 100 mΩ/m @ 10 MHz

—

Application

EMI/RFI protection for signal and control circuits

—



RVVP 2x1.5mm² Shielded Control Panel Wire Braided Copper Relay Circuit EMI Protection 300/500V


5. Installation Practice & Handling. Use crimp lugs and terminal blocks. Ground shield at one or both ends. At 115 kg/km, moderate weight — 35% heavier than RVVP 2×1.0. Indoor use.

Mechanical & Installation Parameters


Parameter

Value

Remarks

Minimum bending radius

≥ 6 × OD → ≈ 49 mm at Ø8.2 mm

flexible conductor, shielded

Max. pulling tension

120 N

fine-stranded Cu (handle gently)

Direct burial

Not recommended​ (no mechanical protection; use conduit)

—

Surface mounting

Good (round profile, cable ties or clips)

—

Conduit ID

≥ 16 mm

—

Fixing

cable ties, clamps, trunking

—

Impact resistance

Low (PVC sheath only)

protect with conduit in exposed areas

Water resistance

Moisture-resistant (PVC)

not waterproof

UV resistance

Poor (PVC degrades in sunlight)

indoor use only

Flex life

High​ (Class 5 fine-stranded, designed for occasional flexing)

—

Termination note

Strip sheath, fold braid back over outer sheath, use heat-shrink or copper strap for shield termination; ferrules recommended for fine-stranded conductors

shield must be grounded at one end (or both, depending on application)


6. Typical Service Applications. PLC I/O modules, relay control panels, sensor power wiring, alarm circuits, motor control interconnection — medium-current control circuits in industrial environments.


RVVP 2x1.5mm² Shielded Control Panel Wire Braided Copper Relay Circuit EMI Protection 300/500V


7. Testing & QA Regime. Routine: conductor DC resistance, 2.0 kV AC withstand, insulation resistance, shield coverage check, dimensional check. Type: heating test, bending test, flame retardancy, mutual capacitance measurement.


Cable Parameters


RVVP 2×1.5 mm² — Shielded Flexible PVC Control Cable — Full Parameter Sheet 
Shielded control · 2× flexible Cu / PVC insulation / copper braid shield / PVC sheath · 300/500 V · 70 °C · ≈ 7.6 mm · medium control signal
Section Parameter Value Unit Remarks / Standard
01 · Identification

Cable type RVVP — shielded flexible PVC control cable — Medium control

Rated voltage (U0/U) 300/500 V Signal / control

Number of cores 2 × 1.5 — 2-core

Conductor material Annealed copper, fine-stranded — Class 5 flexible

Insulation material PVC (polyvinyl chloride) — Per core

Shield type Copper wire braid (P) — ≥ 80% coverage

Sheath material PVC (outer, dark green) — Flexible

Standard GB/T 9330 / IEC 60227 — Control cable

Application Medium control circuits, PLC IO, relay wiring, sensor power — Control
02 · Conductor (Flexible Cu)

Conductor type Fine-stranded annealed copper — Class 5 flexible

Conductor area 2 × 1.5 mm² 2-core

Stranding construction ≈ 30 × 0.25 mm (approx.) — Fine strands

DC resistance @ 20 °C ≤ 13.3 Ω/km Cu 1.5 mm² flexible

Conductor weight per km ≈ 28 kg/km 2×1.5 Cu

Conductor diameter ≈ 1.6 mm Flexible stranded
03 · Insulation & Shield

Insulation type PVC (per core) — General-purpose

Insulation thickness ≈ 0.7 mm 300/500 V

Insulated core OD ≈ 3.0 mm Per core

Shield type Copper wire braid — P = shield

Shield coverage ≥ 80 % EMI protection

Shield diameter ≈ 6.5 mm Over cores
04 · Sheath

Sheath type PVC outer sheath — Flexible

Sheath thickness ≈ 1.2 mm Control cable

Finished outer diameter ≈ 7.6 mm Overall

Sheath color Dark green — Standard
05 · Electrical

Rated voltage (U0/U) 300/500 V Signal / control

Max voltage 500 V Phase-to-phase

DC resistance @ 20 °C ≤ 13.3 Ω/km Flexible Cu 1.5

Test voltage (AC) 2.0 kV / 5 min — Routine

Insulation resistance ≥ 20 MΩ·km PVC

Nominal current (ampacity) ≈ 13 A Medium control

Shield resistance ≤ 20 Ω/km Braid shield
06 · Thermal

Max conductor temp. 70 °C PVC rated

Short-circuit temp. 160 °C Max 5 s

Ambient range -15 ~ +70 °C Indoor

Laying temperature ≥ -10 °C Flexible
07 · Mechanical & Shield

Min bending radius (fixed) ≥ 6 × OD ≈ 46 mm Shielded

Flexibility Good — Flexible

Shield attenuation EMI/RFI protected — Copper braid

Cable weight per km ≈ 115 kg/km Moderate
08 · Installation

Laying methods PLC IO, relay panels, sensor power, control circuits — Control

Connectors Crimp lugs / ferrules / terminal blocks — Shielded

Shield termination Ground at one or both ends — Per system

Bend radius ≥ 6 × OD ≈ 46 mm — Shielded
09 · Packing

Standard supply length 100 m / coil m Control cable

Reel / packing type Coil, wrapped — Plastic bag

Surface marking RVVP, 2×1.5, 300/500V, GB/T 9330 — Continuous printing

Approx. cable weight ≈ 115 kg/km 2-core shielded
10 · Applications

Typical use PLC I/O, relay control, sensor power, alarm circuits, medium control — Control

Max system voltage 500 V 300/500 V

Application level Control / signal — Medium


Cable Test Parameters


Test Parameters — RVVP 2×1.5 mm² Shielded Control Cable
No. Test Item Test Condition / Method Requirement Type
1 Conductor DC resistance GB/T 3956, 20 °C ≤ 13.3 Ω/km (flexible Cu 1.5) Routine
2 Voltage test (AC) 2.0 kV AC, 5 min No breakdown Routine
3 Insulation resistance 500 V DC ≥ 20 MΩ·km Routine
4 Insulation thickness Micrometer ≥ 0.7 mm Routine
5 Shield coverage Visual / microscopic ≥ 80% braid coverage Routine
6 Shield continuity Per GB/T 9330 Shield electrically continuous Routine
7 Heating test 70 °C conductor, 2 h No damage Type
8 Flexibility / bending test 6× OD, cycles No damage Type
9 Flame retardancy IEC 60332-1 Self-extinguishing Type
10 Dimensional check Caliper OD ≈ 7.6 mm Routine
11 Mutual capacitance Per GB/T 9330 ≤ 200 pF/m Type
12 Printing legibility Visual Marking readable Routine


Cable Cross Section Structure

RVVP 2x1.5mm² Shielded Control Panel Wire Braided Copper Relay Circuit EMI Protection 300/500V


RVVP 2×1.5 mm² — Cross-Section Construction Diagram (Schematic)
Shielded control: 2×flexible Cu → PVC insulation → copper braid shield → PVC sheath · 300/500 V · ≈ 7.6 mm
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductors (×2) Fine-stranded annealed Cu, Class 5, 2×1.5 mm² — ≈ 1.6 each R ≤ 13.3 Ω/km
2 PVC insulation Polyvinyl chloride, per core ≈ 0.7 ≈ 3.0 each 300/500 V rated
3 Copper braid shield Tinned copper wire braid, ≥ 80% coverage ≈ 0.5 ≈ 6.5 EMI/RFI protection
4 PVC outer sheath PVC, dark green ≈ 1.2 ≈ 7.6 Outer protection
Key Dimensions & Properties (expanded)
Finished cable diameter ≈ 7.6 mm Overall

Approx. cable mass ≈ 115 kg/km Moderate

Nominal voltage rating 300/500 V Signal / control

Max conductor temp. 70 °C PVC rated

Short-circuit temp. 160 °C Max 5 s

Min bending radius (fixed) ≥ 6 × OD ≈ 46 mm Shielded

DC resistance @ 20 °C ≤ 13.3 Ω/km Flexible Cu 1.5

Test voltage (AC) 2.0 kV / 5 min — Routine

Nominal current (ampacity) ≈ 13 A Medium control

Shield coverage ≥ 80 % Copper braid

Shield resistance ≤ 20 Ω/km Braid

Number of cores 2 — Signal pair

Standard GB/T 9330 / IEC 60227 — Control cable

Application PLC / relay / sensor power — Medium control

Schematic — not to exact scale. Finished OD ≈ 7.6 mm and weight ≈ 115 kg/km from cross-referenced industry samples. RVVP 2×1.5 is a shielded flexible control cable for medium control circuits. Values marked (est.) require confirmation against the factory test certificate.


Construction Description


Construction Description — RVVP 2×1.5 mm² shielded control cable
Layer-by-layer shielded control cable: 2×flexible Cu / PVC insulation / copper braid shield / PVC sheath · 300/500 V · 70 °C · ≈ 7.6 mm
1. Product Identity & Ratings
RVVP 2×1.5 is a shielded flexible PVC control cable rated 300/500 V, 70 °C continuous. Built per GB/T 9330 / IEC 60227. Two 1.5 mm² fine-stranded copper conductors enclosed in a copper wire braid shield (≥ 80% coverage) and PVC outer sheath. Designed for medium control circuits. Finished OD ≈ 7.6 mm, mass ≈ 115 kg/km, 100 m coils.
2. Two Fine Flexible Copper Conductors
Two 1.5 mm² fine-stranded annealed copper conductors (Class 5, ~30×0.25 mm). DC resistance ≤ 13.3 Ω/km at 20 °C. The flexible construction handles up to ~13 A for PLC I/O and relay control circuits.
3. Copper Braid Shield
Tinned copper wire braid woven over the insulated cores with ≥ 80% coverage. The shield blocks EMI/RFI from nearby VFDs, motors, and power cables — critical for industrial control environments.
4. PVC Outer Sheath
PVC outer sheath ≈ 1.2 mm thick, dark green. Provides mechanical protection and environmental resistance. The flexible sheath bends easily for panel wiring and equipment interconnection.
5. Site Handling & Operational Notes
• Bend radius 6×OD (≈ 46 mm).  • Use crimp lugs and terminal blocks.  • Ground shield at one or both ends.  • At 115 kg/km, moderate weight.  • Indoor use.  • Medium control (≈ 13 A max).


8. Standards & Conformity. GB/T 9330 (plastic insulated control cables); IEC 60227 (international); GB/T 3956 (Class 5 flexible conductors). Rated 300/500 V.


9. Packaging, Storage & Logistics. 100 m per coil, plastic wrapped. Continuous marking: RVVP, 2×1.5, 300/500V, GB/T 9330. Store dry, indoor.


RVVP 2x1.5mm² Shielded Control Panel Wire Braided Copper Relay Circuit EMI Protection 300/500V


10. Procurement Specification. State "RVVP 2×1.5" + length. Specify shield coverage requirement (≥ 80%). Confirm against factory test certificate.


11. Cable Industry FAQ.

  • Q1: What is the difference between RVVP 2×1.5 and RVVP 2×1.0? The 1.5 mm² version has 50% more copper cross-section, is thicker (7.6 vs 6.8 mm), 35% heavier (115 vs 85 kg/km), and carries 44% more current (13 vs 9 A). It is for industrial control circuits; the 1.0 mm² version is for audio/data.
  • Q2: Why choose 1.5 mm²? When you need to power sensors, solenoids, or relay coils that draw more current (up to ~13 A), 1.5 mm² provides the margin. The 1.0 mm² is limited to ~9 A for audio/data.
  • Q3: Can it drive relay coils? Yes — relay coils typically draw 50–500 mA, well within the 13 A capacity. The shield protects the control signal from nearby VFD noise.
  • Q4: What connectors are used? Crimp lugs, ferrules, or terminal blocks. The 1.6 mm conductor diameter fits standard industrial terminal blocks.
  • Q5: Is the shield the same as 2×1.0? Yes — copper wire braid ≥ 80% coverage. The shield diameter is larger (6.5 vs 5.6 mm) because it wraps larger cores.
  • Q6: Can it be used for sensor power? Yes — 24 VDC sensor power at up to 13 A is well within range. The shield protects the voltage signal from drop and noise.
  • Q7: What is the bending radius? 6×OD ≈ 46 mm — flexible enough for panel wiring.
  • Q8: Can it be used outdoors? No — PVC sheath is not UV-resistant. For outdoor use, use outdoor-rated cable.
  • Q9: How does it compare to RVVP 2×2.5? The 2.5 mm² version carries 16 A and is for heavier control circuits. The 1.5 mm² version carries 13 A and is the sweet spot for PLC I/O and relay control. If you need more than 13 A, step up to 2.5 mm².
  • Q10: What if I run it near VFDs? The copper braid shield helps significantly. Ground the shield at both ends for high-frequency VFD noise. Maintain separation from motor cables.
  • Q11: What is the standard? GB/T 9330 / IEC 60227 for plastic insulated control cables, rated 300/500 V.