RVVP 2x4.0mm² Heavy Duty Shielded Motor Drive Cable Braided Copper EMI Protection 300/500V

RVVP 2x4.0mm² Heavy Duty Shielded Motor Drive Cable Braided Copper EMI Protection 300/500V

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
RVVP 2x4.0mm²

Trading Properties

moq
1 Meter
payment method
L/C,T/T
supply capacity
100000 meters per month

Product Summary

RVVP 2x4.0mm² Heavy Duty Shielded Motor Drive Cable Braided Copper EMI Protection 300/500V Cable Designation & Meaning Code Meaning R Flexible conductor (Class 5 fine-stranded) V PVC insulation V PVC sheath P Copper wire shield (braid or braid+tape) 2×4.0 mm² Two cores, each 4.0 mm² copper ...

Product Details

Conductor (×2):
Copper, Class 5 Fine-stranded Flexible, Nominal 56×∅0.30 Mm (4.0 Mm² Per Core), Conductor Ø ≈ 2.8–3.2 Mm
Insulation (per core):
PVC (polyvinyl Chloride)​ Compound, Nominal Thickness 0.8 Mm, Colour: Red​ (signal/power +) And Black​ (signal/power −) Or As Specified
Lay-up:
Two Cores Twisted Together With PVC Filler To Form Round Core Bundle
Shield:
Copper Wire Braid, Coverage 80% (typical), Or Copper Braid + Aluminium Polyester Tape (optional)
Outer sheath:
PVC (polyvinyl Chloride)​ Compound, Nominal Thickness 1.2 Mm (typical), Colour: Grey​ Or Black​ (round Profile)
Conductor nominal area:
4.0 Mm² (Cu)
Number of cores:
2
Conductor material:
Copper (Cu)
Conductor class:
Class 5 Fine-stranded Flexible
Conductor construction:
56×∅0.30 Mm (typical)
Conductor diameter (approx.):
2.8–3.2 Mm
Insulation thickness (per core):
0.8 Mm
Shield coverage:
80%
Outer sheath thickness:
1.2 Mm
Overall cable diameter:
10.0 – 12.5 Mm
Design outer diameter:
≈ 11.2 Mm
Approx. weight:
0.155 – 0.195 Kg/m (155–195 Kg/km)
Design weight:
≈ 175 Kg/km
Cable shape:
Round

Product Description

RVVP 2x4.0mm² Heavy Duty Shielded Motor Drive Cable Braided Copper EMI Protection 300/500V

Cable Designation & Meaning


Code

Meaning

R

Flexible conductor (Class 5 fine-stranded)

V

PVC insulation

V

PVC sheath

P

Copper wire shield (braid or braid+tape)

2×4.0 mm²

Two cores, each 4.0 mm² copper


Construction: Two fine-stranded flexible copper conductors, each PVC insulated, laid up with fillers to form a round core assembly, wrapped with copper braid shield (typically 85%–90% coverage), and extruded with a common round PVC outer sheath.

Applicable Standards

  • JB/T 8734.5-2016 — Rated voltages up to and including 450/750 V PVC insulated cables and cords for fixed wiring and flexible applications — Part 5: Shielded flexible cables
  • GB/T 5023.5-2008 / IEC 60227-5 — Polyvinyl chloride insulated cables — Flexible cables (cords)
  • GB/T 3956 / IEC 60228 — Conductors (Class 5 flexible copper)
  • GB/T 2951 / IEC 60811 — Insulating and sheathing materials — Common test methods
  • GB/T 18380 / IEC 60332-1 — Flame retardant (single cable, passes)
  • GB/T 5441 — Communication cable test methods (shielding effectiveness reference)

RVVP 2x4.0mm² Heavy Duty Shielded Motor Drive Cable Braided Copper EMI Protection 300/500V

RVVP 2×4.0 mm² — Heavy Shielded Flexible PVC Control Cable — Specification & Engineering Data

1. Overview & Ratings. RVVP 2×4.0 is a heavy shielded flexible PVC control cable rated 300/500 V, 70 °C continuous. Built per GB/T 9330 / IEC 60227. Two 4.0 mm² large flexible copper conductors (~56×0.30 mm) enclosed in a heavy copper wire braid shield (≥ 80% coverage) and PVC outer sheath. Designed for motor power and heavy control circuits. Finished OD ≈ 10.0 mm, ≈ 190 kg/km, 100 m coils.


2. Construction Stack (Conductor → Outer).

Layer Build Wall Diameter
Conductors (×2) Large flexible Cu, Class 5, 2×4.0 mm² — ≈ 2.5 mm each
PVC insulation Polyvinyl chloride, per core ≈ 0.8 mm ≈ 4.2 mm each
Heavy copper braid shield Tinned copper wire braid, ≥ 80% coverage ≈ 0.6 mm ≈ 8.5 mm
PVC outer sheath PVC, dark brown ≈ 1.4 mm ≈ 10.0 mm (finished)


3. Electrical Characteristics. DC resistance ≤ 4.61 Ω/km at 20 °C (flexible Cu 4.0 mm²); test voltage 2.0 kV AC / 5 min; insulation resistance ≥ 20 MΩ·km. Shield resistance ≤ 15 Ω/km. Nominal ampacity ≈ 23 A (heavy control). Mutual capacitance ≤ 200 pF/m.

Insulation & Sheath Data

Property

Value

Insulation material

PVC (polyvinyl chloride), Type TI1/TI2

Outer sheath material

PVC (polyvinyl chloride), Type TM1/TM2

Long-term service temp.

70 °C (continuous, both insulation & sheath)

Short-circuit temp. (≤5 s)

160 °C (Cu conductor limit for PVC)

Emergency overload temp.

105 °C (short term)

Test voltage AC (5 min)

2.0 kV (routine test, 300/500 V class)

Dielectric strength

≥ 15 kV/mm (room temp.)

Shielding effectiveness

≥ 60 dB at 30 MHz – 100 MHz (typical copper braid)

Transfer impedance

≤ 100 mΩ/m at 10 MHz (typical)

Electrical Parameters



Parameter

Value

Note

Rated voltage U₀/U

300 / 500 V

JB/T 8734.5 / GB/T 5023.5

Max. system voltage

500 V AC

—

Test voltage AC (5 min)

2.0 kV

Routine test (core-to-core, core-to-shield)

DC resistance @20 °C

≤ 4.95 Ω/km

GB/T 3956 Class 5 Cu max, 4.0 mm²

AC resistance @70 °C (est.)

≈ 6.3 Ω/km

per core

Current rating in air (30 °C)

25 A​

2-core, open air, reference value

Current rating in tray (30 °C)

22 A​

bundled with other cables

Current rating in conduit (30 °C)

19 A​

enclosed

Short-circuit current (1 s, Cu, 160 °C)

≈ 0.44 kA (440 A)

4.0 mm² Cu

Capacitance (core-to-core, approx.)

≈ 125 pF/m

PVC insulation

Capacitance (core-to-shield, approx.)

≈ 185 pF/m

collective shield

Inductive reactance (approx.)

≈ 0.08 Ω/km

at 50 Hz

Frequency

50/60 Hz AC (signal up to ~10 MHz)

—


Reference values: 2×4.0 mm² at 19–25 A, single-phase 230 V → max load ≈ 4.4–5.8 kW. Suitable for signal + substantial power​ applications (control signals plus motor, solenoid, or heater loads up to ~5 A per core continuously).


4. Thermal & Mechanical. 70 °C continuous; 160 °C short-circuit (≤ 5 s); ambient −15~+70 °C. Bend ≥ 6 × OD ≈ 60 mm. Handles up to ~23 A for motor power and drive interconnection.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

70 °C (continuous)

Max. short-circuit temp. (≤5 s)

160 °C (Cu conductor, PVC limit)

Emergency overload temp.

105 °C (not recommended for continuous)

Min. installation ambient temp.

0 °C (PVC); below 0 °C pre-heating required

Service ambient range

−15 °C to +70 °C (PVC insulation & sheath)

Flexing temp. range

+5 °C to +70 °C (recommended for repeated bending)

Fire survival

Standard (flame retardant single cable)

Fire Performance (RVVP — Standard)

Property

Value / Requirement

Flame retardant

IEC 60332-1 (single cable, passes)

Halogen content

Contains halogen (PVC insulation & sheath)

Smoke density

Standard (non-low-smoke)

Corrosivity

Corrosive (PVC)

Fire survival (circuit integrity)

Not applicable (standard version)

EMI shielding

Yes​ (copper braid, 85%–90% coverage)

RVVP 2x4.0mm² Heavy Duty Shielded Motor Drive Cable Braided Copper EMI Protection 300/500V

Shielding Performance

Parameter

Value

Note

Shield type

Copper wire braid (bare or tinned)

—

Coverage

85%–90% (typical)

>90% available on request

Optional

Copper braid + aluminium polyester tape (dual shield)

for high EMI environments

Drain wire

Not required (braid is continuous)

—

Shielding effectiveness

≥ 60 dB @ 30–100 MHz

typical braid

Transfer impedance

≤ 100 mΩ/m @ 10 MHz

—

Application

EMI/RFI protection for signal and control circuits

—


RVVP 2x4.0mm² Heavy Duty Shielded Motor Drive Cable Braided Copper EMI Protection 300/500V


5. Installation Practice & Handling. Use crimp lugs and heavy terminal blocks. Ground shield at both ends for high-frequency VFD noise. At 190 kg/km, heavy — 46% heavier than RVVP 2×2.5. Indoor use.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 6 × OD → ≈ 67 mm at Ø11.2 mm

flexible conductor, shielded

Max. pulling tension

320 N

fine-stranded Cu (handle gently)

Direct burial

Not recommended​ (no mechanical protection; use conduit)

—

Surface mounting

Good (round profile, cable ties or clips)

—

Conduit ID

≥ 20 mm

—

Fixing

cable ties, clamps, trunking

—

Impact resistance

Low (PVC sheath only)

protect with conduit in exposed areas

Water resistance

Moisture-resistant (PVC)

not waterproof

UV resistance

Poor (PVC degrades in sunlight)

indoor use only

Flex life

High​ (Class 5 fine-stranded, designed for occasional flexing)

—

Termination note

Strip sheath, fold braid back over outer sheath, use heat-shrink or copper strap for shield termination; ferrules recommended for fine-stranded conductors

shield must be grounded at one end (or both, depending on application)


6. Typical Service Applications. Motor power leads, VFD drive interconnection, heavy control circuits, equipment power distribution, shielded power runs in noisy industrial environments.


RVVP 2x4.0mm² Heavy Duty Shielded Motor Drive Cable Braided Copper EMI Protection 300/500V


7. Testing & QA Regime. Routine: conductor DC resistance, 2.0 kV AC withstand, insulation resistance, shield coverage check, dimensional check. Type: heating test, bending test, flame retardancy, mutual capacitance measurement.


Cable Parameters


RVVP 2×4.0 mm² — Heavy Shielded Flexible PVC Control Cable — Full Parameter Sheet 
Heavy shielded control · 2× large flexible Cu / PVC insulation / copper braid shield / PVC sheath · 300/500 V · 70 °C · ≈ 10.0 mm · heavy control / power
Section Parameter Value Unit Remarks / Standard
01 · Identification

Cable type RVVP — heavy shielded flexible PVC control cable — Heavy control

Rated voltage (U0/U) 300/500 V Signal / control

Number of cores 2 × 4.0 — 2-core

Conductor material Annealed copper, fine-stranded — Class 5 flexible

Insulation material PVC (polyvinyl chloride) — Per core

Shield type Copper wire braid (P) — ≥ 80% coverage

Sheath material PVC (outer, dark brown) — Flexible

Standard GB/T 9330 / IEC 60227 — Control cable

Application Heavy control, motor power, drive interconnection, power control — Heavy
02 · Conductor (Flexible Cu)

Conductor type Fine-stranded annealed copper — Class 5 flexible

Conductor area 2 × 4.0 mm² 2-core heavy

Stranding construction ≈ 56 × 0.30 mm (approx.) — Large strands

DC resistance @ 20 °C ≤ 4.61 Ω/km Cu 4.0 mm² flexible

Conductor weight per km ≈ 76 kg/km 2×4.0 Cu

Conductor diameter ≈ 2.5 mm Flexible stranded
03 · Insulation & Shield

Insulation type PVC (per core) — General-purpose

Insulation thickness ≈ 0.8 mm 300/500 V

Insulated core OD ≈ 4.2 mm Per core

Shield type Copper wire braid — P = shield

Shield coverage ≥ 80 % EMI protection

Shield diameter ≈ 8.5 mm Over cores
04 · Sheath

Sheath type PVC outer sheath — Flexible

Sheath thickness ≈ 1.4 mm Heavy control

Finished outer diameter ≈ 10.0 mm Overall

Sheath color Dark brown — Standard
05 · Electrical

Rated voltage (U0/U) 300/500 V Signal / control

Max voltage 500 V Phase-to-phase

DC resistance @ 20 °C ≤ 4.61 Ω/km Flexible Cu 4.0

Test voltage (AC) 2.0 kV / 5 min — Routine

Insulation resistance ≥ 20 MΩ·km PVC

Nominal current (ampacity) ≈ 23 A Heavy control

Shield resistance ≤ 15 Ω/km Heavy braid
06 · Thermal

Max conductor temp. 70 °C PVC rated

Short-circuit temp. 160 °C Max 5 s

Ambient range -15 ~ +70 °C Indoor

Laying temperature ≥ -10 °C Flexible
07 · Mechanical & Shield

Min bending radius (fixed) ≥ 6 × OD ≈ 60 mm Heavy shielded

Flexibility Moderate — Large flexible

Shield attenuation EMI/RFI protected — Copper braid

Cable weight per km ≈ 190 kg/km Heavy
08 · Installation

Laying methods Motor power, drive interconnection, heavy control, equipment power — Heavy

Connectors Crimp lugs / ferrules / terminal blocks — Shielded

Shield termination Ground at one or both ends — Per system

Bend radius ≥ 6 × OD ≈ 60 mm — Heavy
09 · Packing

Standard supply length 100 m / coil m Control cable

Reel / packing type Coil, wrapped — Plastic bag

Surface marking RVVP, 2×4.0, 300/500V, GB/T 9330 — Continuous printing

Approx. cable weight ≈ 190 kg/km 2-core heavy shielded
10 · Applications

Typical use Motor power, drive interconnection, heavy control, equipment power, shielded power — Heavy

Max system voltage 500 V 300/500 V

Application level Heavy control / power — High current


Cable Test Parameters


Test Parameters — RVVP 2×4.0 mm² Heavy Shielded Control Cable
No. Test Item Test Condition / Method Requirement Type
1 Conductor DC resistance GB/T 3956, 20 °C ≤ 4.61 Ω/km (flexible Cu 4.0) Routine
2 Voltage test (AC) 2.0 kV AC, 5 min No breakdown Routine
3 Insulation resistance 500 V DC ≥ 20 MΩ·km Routine
4 Insulation thickness Micrometer ≥ 0.8 mm Routine
5 Shield coverage Visual / microscopic ≥ 80% braid coverage Routine
6 Shield continuity Per GB/T 9330 Shield electrically continuous Routine
7 Heating test 70 °C conductor, 2 h No damage Type
8 Flexibility / bending test 6× OD, cycles No damage Type
9 Flame retardancy IEC 60332-1 Self-extinguishing Type
10 Dimensional check Caliper OD ≈ 10.0 mm Routine
11 Mutual capacitance Per GB/T 9330 ≤ 200 pF/m Type
12 Printing legibility Visual Marking readable Routine


Cable Cross Section Structure

RVVP 2x4.0mm² Heavy Duty Shielded Motor Drive Cable Braided Copper EMI Protection 300/500V

RVVP 2×4.0 mm² — Cross-Section Construction Diagram (Schematic)
Heavy shielded control: 2×large flexible Cu → PVC insulation → copper braid shield → PVC sheath · 300/500 V · ≈ 10.0 mm
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductors (×2) Fine-stranded annealed Cu, Class 5, 2×4.0 mm² — ≈ 2.5 each R ≤ 4.61 Ω/km
2 PVC insulation Polyvinyl chloride, per core ≈ 0.8 ≈ 4.2 each 300/500 V rated
3 Copper braid shield Tinned copper wire braid, ≥ 80% coverage ≈ 0.6 ≈ 8.5 EMI/RFI protection
4 PVC outer sheath PVC, dark brown ≈ 1.4 ≈ 10.0 Outer protection
Key Dimensions & Properties (expanded)
Finished cable diameter ≈ 10.0 mm Overall

Approx. cable mass ≈ 190 kg/km Heavy

Nominal voltage rating 300/500 V Signal / control

Max conductor temp. 70 °C PVC rated

Short-circuit temp. 160 °C Max 5 s

Min bending radius (fixed) ≥ 6 × OD ≈ 60 mm Heavy shielded

DC resistance @ 20 °C ≤ 4.61 Ω/km Flexible Cu 4.0

Test voltage (AC) 2.0 kV / 5 min — Routine

Nominal current (ampacity) ≈ 23 A Heavy control

Shield coverage ≥ 80 % Copper braid

Shield resistance ≤ 15 Ω/km Heavy braid

Number of cores 2 — Power pair

Standard GB/T 9330 / IEC 60227 — Control cable

Application Motor power / heavy control — High current

Schematic — not to exact scale. Finished OD ≈ 10.0 mm and weight ≈ 190 kg/km from cross-referenced industry samples. RVVP 2×4.0 is a heavy shielded flexible control cable for motor power and heavy control circuits. Values marked (est.) require confirmation against the factory test certificate.


Construction Description


Construction Description — RVVP 2×4.0 mm² heavy shielded control cable
Layer-by-layer heavy shielded control cable: 2×large flexible Cu / PVC insulation / copper braid shield / PVC sheath · 300/500 V · 70 °C · ≈ 10.0 mm
1. Product Identity & Ratings
RVVP 2×4.0 is a heavy shielded flexible PVC control cable rated 300/500 V, 70 °C continuous. Built per GB/T 9330 / IEC 60227. Two 4.0 mm² large flexible copper conductors enclosed in a copper wire braid shield (≥ 80% coverage) and PVC outer sheath. Designed for motor power and heavy control circuits. Finished OD ≈ 10.0 mm, mass ≈ 190 kg/km, 100 m coils.
2. Two Large Flexible Copper Conductors
Two 4.0 mm² fine-stranded annealed copper conductors (Class 5, ~56×0.30 mm). DC resistance ≤ 4.61 Ω/km at 20 °C. The large flexible construction handles up to ~23 A for motor power and drive interconnection.
3. Heavy Copper Braid Shield
Tinned copper wire braid woven over the insulated cores with ≥ 80% coverage. The heavier braid shield blocks EMI/RFI from VFDs, motors, and power cables — critical when carrying both power and signal in noisy industrial environments.
4. PVC Outer Sheath
PVC outer sheath ≈ 1.4 mm thick, dark brown. Provides heavy-duty mechanical protection. The flexible sheath bends for equipment interconnection but requires a generous 6×OD bend radius.
5. Site Handling & Operational Notes
• Bend radius 6×OD (≈ 60 mm).  • Use crimp lugs and heavy terminal blocks.  • Ground shield at both ends.  • At 190 kg/km, heavy.  • Indoor use.  • Heavy control / power (≈ 23 A max).


8. Standards & Conformity. GB/T 9330 (plastic insulated control cables); IEC 60227 (international); GB/T 3956 (Class 5 flexible conductors). Rated 300/500 V.


9. Packaging, Storage & Logistics. 100 m per coil, plastic wrapped. Continuous marking: RVVP, 2×4.0, 300/500V, GB/T 9330. Store dry, indoor.


RVVP 2x4.0mm² Heavy Duty Shielded Motor Drive Cable Braided Copper EMI Protection 300/500V


10. Procurement Specification. State "RVVP 2×4.0" + length. Specify shield coverage requirement (≥ 80%). Confirm against factory test certificate.


11. Cable Industry FAQ.

  • Q1: What is the difference between RVVP 2×4.0 and RVVP 2×2.5? The 4.0 mm² version has 60% more copper cross-section, is 25% thicker (10.0 vs 8.0 mm), 46% heavier (190 vs 130 kg/km), and carries 44% more current (23 vs 16 A). It is for motor power; the 2.5 mm² version is for general control.
  • Q2: Why choose 4.0 mm²? When you need to carry up to ~23 A while maintaining EMI shielding — e.g., powering small motors, solenoids, or drives — 4.0 mm² provides the current capacity. The 2.5 mm² version is limited to ~16 A.
  • Q3: Can it power a small motor? Yes — up to ~23 A at 300/500 V is enough for fractional-horsepower motors and drive inputs. The shield prevents VFD noise from radiating back into the control circuit.
  • Q4: What connectors are used? Heavy crimp lugs, ferrules, or terminal blocks rated for 4 mm² conductors. The 2.5 mm conductor diameter requires larger lugs than the 2.0 mm in RVVP 2×2.5.
  • Q5: Is the shield heavier? Yes — the braid is thicker (0.6 vs 0.5 mm) and shield resistance is lower (≤ 15 vs ≤ 20 Ω/km) because it wraps larger cores. Coverage remains ≥ 80%.
  • Q6: Can it be used as a power cable? It can carry up to 23 A at 300/500 V, but it is not a power cable per se. For true power distribution, use RVV or YJV. RVVP 2×4.0 is for shielded power/control hybrid runs.
  • Q7: What is the bending radius? 6×OD ≈ 60 mm — stiffer than the 48 mm of RVVP 2×2.5 due to the larger conductors.
  • Q8: Can it be used outdoors? No — PVC sheath is not UV-resistant. For outdoor use, use outdoor-rated cable.
  • Q9: How does it compare to RVVP 2×6.0? The 6.0 mm² version carries ~30 A and is for heavier motor power. The 4.0 mm² version carries 23 A and is the sweet spot for small drives and heavy control. If you need more than 23 A, step up to 6.0 mm².
  • Q10: Should the shield be grounded at one or both ends? For VFD and high-frequency noise, ground at both ends. For low-frequency signals, one end only. With 4.0 mm² power/control hybrid, both ends is typical.
  • Q11: What is the standard? GB/T 9330 / IEC 60227 for plastic insulated control cables, rated 300/500 V.