RVVP 2x6.0mm² High Current Shielded Power Signal Cable Braided Copper EMI 300/500V

RVVP 2x6.0mm² High Current Shielded Power Signal Cable Braided Copper EMI 300/500V

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
RVVP 2x6.0mm²

Trading Properties

moq
1 Meter
payment method
L/C,T/T
supply capacity
100000 meters per month

Product Summary

RVVP 2x6.0mm² High Current Shielded Power Signal Cable Braided Copper EMI 300/500V Cable Designation & Meaning Code Meaning R Flexible conductor (Class 5 fine-stranded) V PVC insulation V PVC sheath P Copper wire shield (braid or braid+tape) 2×6.0 mm² Two cores, each 6.0 mm² copper Construction: Two ...

Product Details

Conductor (×2):
Copper, Class 5 Fine-stranded Flexible, Nominal 84×∅0.30 Mm (6.0 Mm² Per Core), Conductor Ø ≈ 3.5–4.0 Mm
Insulation (per core):
PVC (polyvinyl Chloride)​ Compound, Nominal Thickness 0.8 Mm, Colour: Red​ (signal/power +) And Black​ (signal/power −) Or As Specified
Lay-up:
Two Cores Twisted Together With PVC Filler To Form Round Core Bundle
Shield:
Copper Wire Braid, Coverage 80% (typical), Or Copper Braid + Aluminium Polyester Tape (optional)
Outer sheath:
PVC (polyvinyl Chloride)​ Compound, Nominal Thickness 1.2 Mm (typical), Colour: Grey​ Or Black​ (round Profile)
Conductor nominal area:
6.0 Mm² (Cu)
Number of cores:
2
Conductor material:
Copper (Cu)
Conductor class:
Class 5 Fine-stranded Flexible
Conductor construction:
84×∅0.30 Mm (typical)
Conductor diameter (approx.):
3.5–4.0 Mm
Insulation thickness (per core):
0.8 Mm
Shield coverage:
80%
Outer sheath thickness:
1.2 Mm
Overall cable diameter:
12.0 – 14.5 Mm
Design outer diameter:
≈ 13.2 Mm
Approx. weight:
0.220 – 0.280 Kg/m (220–280 Kg/km)
Design weight:
≈ 248 Kg/km
Cable shape:
Round

Product Description

RVVP 2x6.0mm² High Current Shielded Power Signal Cable Braided Copper EMI 300/500V

Cable Designation & Meaning



Code

Meaning

R

Flexible conductor (Class 5 fine-stranded)

V

PVC insulation

V

PVC sheath

P

Copper wire shield (braid or braid+tape)

2×6.0 mm²

Two cores, each 6.0 mm² copper


Construction: Two fine-stranded flexible copper conductors, each PVC insulated, laid up with fillers to form a round core assembly, wrapped with copper braid shield (typically 85%–90% coverage), and extruded with a common round PVC outer sheath.

Applicable Standards

  • JB/T 8734.5-2016 — Rated voltages up to and including 450/750 V PVC insulated cables and cords for fixed wiring and flexible applications — Part 5: Shielded flexible cables
  • GB/T 5023.5-2008 / IEC 60227-5 — Polyvinyl chloride insulated cables — Flexible cables (cords)
  • GB/T 3956 / IEC 60228 — Conductors (Class 5 flexible copper)
  • GB/T 2951 / IEC 60811 — Insulating and sheathing materials — Common test methods
  • GB/T 18380 / IEC 60332-1 — Flame retardant (single cable, passes)
  • GB/T 5441 — Communication cable test methods (shielding effectiveness reference)

RVVP 2x6.0mm² High Current Shielded Power Signal Cable Braided Copper EMI 300/500V

RVVP 2×6.0 mm² — Extra-Heavy Shielded Flexible PVC Control Cable — Specification & Engineering Data 

1. Overview & Ratings. RVVP 2×6.0 is an extra-heavy shielded flexible PVC control cable rated 300/500 V, 70 °C continuous. Built per GB/T 9330 / IEC 60227. Two 6.0 mm² large flexible copper conductors (~84×0.30 mm) enclosed in a heavy copper wire braid shield (≥ 80% coverage) and PVC outer sheath. This is the largest shielded control cable in the series, for motor drive power. Finished OD ≈ 12.0 mm, ≈ 270 kg/km, 50 m coils.


2. Construction Stack (Conductor → Outer).


Layer Build Wall Diameter
Conductors (×2) Large flexible Cu, Class 5, 2×6.0 mm² — ≈ 2.9 mm each
PVC insulation Polyvinyl chloride, per core ≈ 0.8 mm ≈ 4.5 mm each
Heavy copper braid shield Tinned copper wire braid, ≥ 80% coverage ≈ 0.7 mm ≈ 10.0 mm
PVC outer sheath PVC, dark purple-brown ≈ 1.5 mm ≈ 12.0 mm (finished)


3. Electrical Characteristics. DC resistance ≤ 3.08 Ω/km at 20 °C (flexible Cu 6.0 mm²); test voltage 2.0 kV AC / 5 min; insulation resistance ≥ 20 MΩ·km. Shield resistance ≤ 12 Ω/km. Nominal ampacity ≈ 30 A (motor drive). Mutual capacitance ≤ 200 pF/m.

Insulation & Sheath Data

Property

Value

Insulation material

PVC (polyvinyl chloride), Type TI1/TI2

Outer sheath material

PVC (polyvinyl chloride), Type TM1/TM2

Long-term service temp.

70 °C (continuous, both insulation & sheath)

Short-circuit temp. (≤5 s)

160 °C (Cu conductor limit for PVC)

Emergency overload temp.

105 °C (short term)

Test voltage AC (5 min)

2.0 kV (routine test, 300/500 V class)

Dielectric strength

≥ 15 kV/mm (room temp.)

Shielding effectiveness

≥ 60 dB at 30 MHz – 100 MHz (typical copper braid)

Transfer impedance

≤ 100 mΩ/m at 10 MHz (typical)


Electrical Parameters

Parameter

Value

Note

Rated voltage U₀/U

300 / 500 V

JB/T 8734.5 / GB/T 5023.5

Max. system voltage

500 V AC

—

Test voltage AC (5 min)

2.0 kV

Routine test (core-to-core, core-to-shield)

DC resistance @20 °C

≤ 3.30 Ω/km

GB/T 3956 Class 5 Cu max, 6.0 mm²

AC resistance @70 °C (est.)

≈ 4.2 Ω/km

per core

Current rating in air (30 °C)

32 A​

2-core, open air, reference value

Current rating in tray (30 °C)

28 A​

bundled with other cables

Current rating in conduit (30 °C)

25 A​

enclosed

Short-circuit current (1 s, Cu, 160 °C)

≈ 0.66 kA (660 A)

6.0 mm² Cu

Capacitance (core-to-core, approx.)

≈ 130 pF/m

PVC insulation

Capacitance (core-to-shield, approx.)

≈ 195 pF/m

collective shield

Inductive reactance (approx.)

≈ 0.08 Ω/km

at 50 Hz

Frequency

50/60 Hz AC (signal up to ~10 MHz)

—


Reference values: 2×6.0 mm² at 25–32 A, single-phase 230 V → max load ≈ 5.8–7.4 kW. Suitable for signal + high power​ applications (control signals plus motor, heater, or solenoid loads up to ~7 A per core continuously). This is the maximum power capacity​ available in the RVVP flexible shielded control cable series.


4. Thermal & Mechanical. 70 °C continuous; 160 °C short-circuit (≤ 5 s); ambient −15~+70 °C. Bend ≥ 6 × OD ≈ 72 mm. Handles up to ~30 A for motor drive and VFD interconnection.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

70 °C (continuous)

Max. short-circuit temp. (≤5 s)

160 °C (Cu conductor, PVC limit)

Emergency overload temp.

105 °C (not recommended for continuous)

Min. installation ambient temp.

0 °C (PVC); below 0 °C pre-heating required

Service ambient range

−15 °C to +70 °C (PVC insulation & sheath)

Flexing temp. range

+5 °C to +70 °C (recommended for repeated bending)

Fire survival

Standard (flame retardant single cable)

Fire Performance (RVVP — Standard)

Property

Value / Requirement

Flame retardant

IEC 60332-1 (single cable, passes)

Halogen content

Contains halogen (PVC insulation & sheath)

Smoke density

Standard (non-low-smoke)

Corrosivity

Corrosive (PVC)

Fire survival (circuit integrity)

Not applicable (standard version)

EMI shielding

Yes​ (copper braid, 85%–90% coverage)


RVVP 2x6.0mm² High Current Shielded Power Signal Cable Braided Copper EMI 300/500V

Shielding Performance

Parameter

Value

Note

Shield type

Copper wire braid (bare or tinned)

—

Coverage

85%–90% (typical)

>90% available on request

Optional

Copper braid + aluminium polyester tape (dual shield)

for high EMI environments

Drain wire

Not required (braid is continuous)

—

Shielding effectiveness

≥ 60 dB @ 30–100 MHz

typical braid

Transfer impedance

≤ 100 mΩ/m @ 10 MHz

—

Application

EMI/RFI protection for signal and control circuits

—


RVVP 2x6.0mm² High Current Shielded Power Signal Cable Braided Copper EMI 300/500V


5. Installation Practice & Handling. Use heavy crimp lugs and terminal blocks. Ground shield at both ends for VFD noise. At 270 kg/km, extra heavy — 42% heavier than RVVP 2×4.0. Indoor use.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 6 × OD → ≈ 79 mm at Ø13.2 mm

flexible conductor, shielded

Max. pulling tension

480 N

fine-stranded Cu (handle gently)

Direct burial

Not recommended​ (no mechanical protection; use conduit)

—

Surface mounting

Good (round profile, heavy-duty cable ties or clamps)

—

Conduit ID

≥ 25 mm

—

Fixing

heavy-duty cable ties, clamps, trunking

—

Impact resistance

Low (PVC sheath only)

protect with conduit in exposed areas

Water resistance

Moisture-resistant (PVC)

not waterproof

UV resistance

Poor (PVC degrades in sunlight)

indoor use only

Flex life

High​ (Class 5 fine-stranded, designed for occasional flexing)

—

Termination note

Strip sheath, fold braid back over outer sheath, use heat-shrink or copper strap for shield termination; ferrules recommended for fine-stranded conductors

shield must be grounded at one end (or both, depending on application)


6. Typical Service Applications. Motor drive power leads, VFD interconnection, heavy equipment power, shielded power runs in industrial plants — where high-current power must be shielded from neighboring control circuits.


RVVP 2x6.0mm² High Current Shielded Power Signal Cable Braided Copper EMI 300/500V


7. Testing & QA Regime. Routine: conductor DC resistance, 2.0 kV AC withstand, insulation resistance, shield coverage check, dimensional check. Type: heating test, bending test, flame retardancy, mutual capacitance measurement.


Cable Parameters


RVVP 2×6.0 mm² — Extra-Heavy Shielded Flexible PVC Control Cable — Full Parameter Sheet 
Extra-heavy shielded · 2× large flexible Cu / PVC insulation / copper braid shield / PVC sheath · 300/500 V · 70 °C · ≈ 12.0 mm · motor drive power
Section Parameter Value Unit Remarks / Standard
01 · Identification

Cable type RVVP — extra-heavy shielded flexible PVC control cable — Motor drive

Rated voltage (U0/U) 300/500 V Signal / control

Number of cores 2 × 6.0 — 2-core

Conductor material Annealed copper, fine-stranded — Class 5 flexible

Insulation material PVC (polyvinyl chloride) — Per core

Shield type Copper wire braid (P) — ≥ 80% coverage

Sheath material PVC (outer, dark purple-brown) — Flexible

Standard GB/T 9330 / IEC 60227 — Control cable

Application Motor drive power, heavy equipment interconnection, shielded power — Extra heavy
02 · Conductor (Flexible Cu)

Conductor type Fine-stranded annealed copper — Class 5 flexible

Conductor area 2 × 6.0 mm² 2-core extra heavy

Stranding construction ≈ 84 × 0.30 mm (approx.) — Large strands

DC resistance @ 20 °C ≤ 3.08 Ω/km Cu 6.0 mm² flexible

Conductor weight per km ≈ 114 kg/km 2×6.0 Cu

Conductor diameter ≈ 2.9 mm Flexible stranded
03 · Insulation & Shield

Insulation type PVC (per core) — General-purpose

Insulation thickness ≈ 0.8 mm 300/500 V

Insulated core OD ≈ 4.5 mm Per core

Shield type Copper wire braid — P = shield

Shield coverage ≥ 80 % EMI protection

Shield diameter ≈ 10.0 mm Over cores
04 · Sheath

Sheath type PVC outer sheath — Flexible

Sheath thickness ≈ 1.5 mm Extra heavy

Finished outer diameter ≈ 12.0 mm Overall

Sheath color Dark purple-brown — Standard
05 · Electrical

Rated voltage (U0/U) 300/500 V Signal / control

Max voltage 500 V Phase-to-phase

DC resistance @ 20 °C ≤ 3.08 Ω/km Flexible Cu 6.0

Test voltage (AC) 2.0 kV / 5 min — Routine

Insulation resistance ≥ 20 MΩ·km PVC

Nominal current (ampacity) ≈ 30 A Motor drive

Shield resistance ≤ 12 Ω/km Heavy braid
06 · Thermal

Max conductor temp. 70 °C PVC rated

Short-circuit temp. 160 °C Max 5 s

Ambient range -15 ~ +70 °C Indoor

Laying temperature ≥ -10 °C Flexible
07 · Mechanical & Shield

Min bending radius (fixed) ≥ 6 × OD ≈ 72 mm Extra heavy

Flexibility Moderate — Large flexible

Shield attenuation EMI/RFI protected — Copper braid

Cable weight per km ≈ 270 kg/km Extra heavy
08 · Installation

Laying methods Motor drive, heavy equipment, shielded power, VFD interconnection — Extra heavy

Connectors Crimp lugs / ferrules / heavy terminal blocks — Shielded

Shield termination Ground at both ends — VFD noise

Bend radius ≥ 6 × OD ≈ 72 mm — Extra heavy
09 · Packing

Standard supply length 50 m / coil m Heavy cable

Reel / packing type Coil, wrapped — Plastic bag

Surface marking RVVP, 2×6.0, 300/500V, GB/T 9330 — Continuous printing

Approx. cable weight ≈ 270 kg/km 2-core extra heavy shielded
10 · Applications

Typical use Motor drive power, VFD interconnection, heavy equipment, shielded power runs — Extra heavy

Max system voltage 500 V 300/500 V

Application level Motor drive / heavy power — High current


Cable Test Parameters


Test Parameters — RVVP 2×6.0 mm² Extra-Heavy Shielded Control Cable
No. Test Item Test Condition / Method Requirement Type
1 Conductor DC resistance GB/T 3956, 20 °C ≤ 3.08 Ω/km (flexible Cu 6.0) Routine
2 Voltage test (AC) 2.0 kV AC, 5 min No breakdown Routine
3 Insulation resistance 500 V DC ≥ 20 MΩ·km Routine
4 Insulation thickness Micrometer ≥ 0.8 mm Routine
5 Shield coverage Visual / microscopic ≥ 80% braid coverage Routine
6 Shield continuity Per GB/T 9330 Shield electrically continuous Routine
7 Heating test 70 °C conductor, 2 h No damage Type
8 Flexibility / bending test 6× OD, cycles No damage Type
9 Flame retardancy IEC 60332-1 Self-extinguishing Type
10 Dimensional check Caliper OD ≈ 12.0 mm Routine
11 Mutual capacitance Per GB/T 9330 ≤ 200 pF/m Type
12 Printing legibility Visual Marking readable Routine


Cable Cross Section Structure


RVVP 2x6.0mm² High Current Shielded Power Signal Cable Braided Copper EMI 300/500V

RVVP 2×6.0 mm² — Cross-Section Construction Diagram (Schematic)
Extra-heavy shielded: 2×large flexible Cu → PVC insulation → copper braid shield → PVC sheath · 300/500 V · ≈ 12.0 mm
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductors (×2) Large flexible Cu, Class 5, 2×6.0 mm² — ≈ 2.9 each R ≤ 3.08 Ω/km
2 PVC insulation Polyvinyl chloride, per core ≈ 0.8 ≈ 4.5 each 300/500 V rated
3 Copper braid shield Tinned copper wire braid, ≥ 80% coverage ≈ 0.7 ≈ 10.0 EMI/RFI protection
4 PVC outer sheath PVC, dark purple-brown ≈ 1.5 ≈ 12.0 Outer protection
Key Dimensions & Properties (expanded)
Finished cable diameter ≈ 12.0 mm Overall

Approx. cable mass ≈ 270 kg/km Extra heavy

Nominal voltage rating 300/500 V Signal / control

Max conductor temp. 70 °C PVC rated

Short-circuit temp. 160 °C Max 5 s

Min bending radius (fixed) ≥ 6 × OD ≈ 72 mm Extra heavy

DC resistance @ 20 °C ≤ 3.08 Ω/km Flexible Cu 6.0

Test voltage (AC) 2.0 kV / 5 min — Routine

Nominal current (ampacity) ≈ 30 A Motor drive

Shield coverage ≥ 80 % Copper braid

Shield resistance ≤ 12 Ω/km Heavy braid

Number of cores 2 — Power pair

Standard GB/T 9330 / IEC 60227 — Control cable

Application Motor drive / VFD power — High current

Schematic — not to exact scale. Finished OD ≈ 12.0 mm and weight ≈ 270 kg/km from cross-referenced industry samples. RVVP 2×6.0 is the largest shielded flexible control cable in this series, for motor drive power. Values marked (est.) require confirmation against the factory test certificate.


Construction Description


Construction Description — RVVP 2×6.0 mm² extra-heavy shielded control cable
Layer-by-layer extra-heavy shielded control cable: 2×large flexible Cu / PVC insulation / copper braid shield / PVC sheath · 300/500 V · 70 °C · ≈ 12.0 mm
1. Product Identity & Ratings
RVVP 2×6.0 is an extra-heavy shielded flexible PVC control cable rated 300/500 V, 70 °C continuous. Built per GB/T 9330 / IEC 60227. Two 6.0 mm² large flexible copper conductors enclosed in a heavy copper wire braid shield (≥ 80% coverage) and PVC outer sheath. This is the largest shielded control cable in the series. Finished OD ≈ 12.0 mm, mass ≈ 270 kg/km, 50 m coils.
2. Two Large Flexible Copper Conductors
Two 6.0 mm² fine-stranded annealed copper conductors (Class 5, ~84×0.30 mm). DC resistance ≤ 3.08 Ω/km at 20 °C. The large flexible construction handles up to ~30 A for motor drive power and VFD interconnection.
3. Heavy Copper Braid Shield
Tinned copper wire braid woven over the insulated cores with ≥ 80% coverage. The heaviest braid in the RVVP series blocks EMI/RFI from VFDs, motors, and power cables — critical when carrying drive power that itself generates noise.
4. PVC Outer Sheath
PVC outer sheath ≈ 1.5 mm thick, dark purple-brown. Provides heavy-duty mechanical protection. The flexible sheath requires a generous 6×OD bend radius (≈ 72 mm).




5. Site Handling & Operational Notes
• Bend radius 6×OD (≈ 72 mm).  • Use heavy crimp lugs and terminal blocks.  • Ground shield at both ends.  • At 270 kg/km, extra heavy.  • Indoor use.  • Motor drive power (≈ 30 A max).


8. Standards & Conformity. GB/T 9330 (plastic insulated control cables); IEC 60227 (international); GB/T 3956 (Class 5 flexible conductors). Rated 300/500 V.


9. Packaging, Storage & Logistics. 50 m per coil (shorter due to weight), plastic wrapped. Continuous marking: RVVP, 2×6.0, 300/500V, GB/T 9330. Store dry, indoor.


RVVP 2x6.0mm² High Current Shielded Power Signal Cable Braided Copper EMI 300/500V


10. Procurement Specification. State "RVVP 2×6.0" + length. Specify shield coverage requirement (≥ 80%). Confirm against factory test certificate.


11. Cable Industry FAQ.

  • Q1: What is the difference between RVVP 2×6.0 and RVVP 2×4.0? The 6.0 mm² version has 50% more copper cross-section, is 20% thicker (12.0 vs 10.0 mm), 42% heavier (270 vs 190 kg/km), and carries 30% more current (30 vs 23 A). It is for motor drives; the 4.0 mm² version is for small motors.
  • Q2: Why choose 6.0 mm²? When you need to carry up to ~30 A with EMI shielding — e.g., powering medium motors, VFD outputs, or heavy equipment — 6.0 mm² provides the margin. The 4.0 mm² version is limited to ~23 A.
  • Q3: Can it power a VFD output? Yes — up to 30 A at 300/500 V is enough for many VFD-driven motors. The shield prevents the VFD's high-frequency PWM noise from radiating into adjacent control circuits.
  • Q4: What connectors are used? Heavy crimp lugs rated for 6 mm² conductors. The 2.9 mm conductor diameter requires larger lugs than the 2.5 mm in RVVP 2×4.0.
  • Q5: Is the shield heavier? Yes — the braid is thicker (0.7 vs 0.6 mm) and shield resistance is lower (≤ 12 vs ≤ 15 Ω/km). Coverage remains ≥ 80%.
  • Q6: Can it be used as a main power cable? It can carry 30 A at 300/500 V, but it is a shielded control/power hybrid. For main power distribution, use RVV or YJV. RVVP 2×6.0 is for shielded motor drive runs.
  • Q7: What is the bending radius? 6×OD ≈ 72 mm — the stiffest in the RVVP series due to the large conductors.
  • Q8: Can it be used outdoors? No — PVC sheath is not UV-resistant. For outdoor use, use outdoor-rated cable.
  • Q9: Is this the largest RVVP? Yes — 6.0 mm² is the largest standard shielded flexible control cable in this series. Beyond 6.0 mm², use unshielded RVV or armored YJV.
  • Q10: Why shorter coil length (50 m)? At 270 kg/km, a 100 m coil would weigh 27 kg — difficult to handle. 50 m coils (≈ 13.5 kg) are more practical for this size.
  • Q11: What is the standard? GB/T 9330 / IEC 60227 for plastic insulated control cables, rated 300/500 V.