"zr yjv 4 cores cable"
- 63 Items Found
Flame Retardant XLPE Insulated ZR-YJV 3×185mm²+1×95mm² Copper Cable for Power Grid Distribution Projects
Flame Retardant XLPE Insulated ZR-YJV 3×185mm²+1×95mm² Copper Cable for Power Grid Distribution Projects Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 3×185 mm² + 1×95 mm² Three phase cores of 185 ...
ZR-YJV 4*16mm² Fire Retardant Four Conductor Cable, 0.6/1kV, XLPE PVC Sheath for Indoor Power Wiring
ZR-YJV 4*16mm² Fire Retardant Four Conductor Cable, 0.6/1kV, XLPE PVC Sheath for Indoor Power Wiring Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×16 mm² Four equal cores of 16 mm² copper ...
ZR-YJV 4×25mm² Flame Retardant Copper Power Cable, 0.6/1kV XLPE Insulated PVC Sheath
ZR-YJV 4×25mm² Flame Retardant Copper Power Cable, 0.6/1kV XLPE Insulated PVC Sheath Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×25 mm² Four equal cores of 25 mm² copper conductor Construction ...
ZR-YJV 4 Core Electrical Cable 4x185mm2 Flame Retardant Copper Power Distribution
ZR-YJV 4*185mm² Flame Retardant 4 Core Copper Power Distribution Cable Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×185 mm² Four cores of 185 mm² copper conductor each (3 phase + 1 neutral, ...
ZR-YJV 1*240mm² Fire Retardant Single Conductor Cable, 0.6/1kV Pure Copper, XLPE PVC Sheath for Indoor Power Wiring
ZR-YJV 1*240mm² Fire Retardant Single Conductor Cable, 0.6/1kV Pure Copper, XLPE PVC Sheath for Indoor Power Wiring Code Mean:ZR-Flame Retardant,YJ-XLPE Insulation,V-PVC Outer Sheathed ZR-YJV 1×240 mm² — Product Briefing 1. What It Is. The ZR-YJV 1×240 is the heavy feeder class of the flame...
Copper Conductor Flame Retardant XLPE Cable ZR-YJV 3×95mm²+1×50mm² for Site Power Wiring
Copper Conductor Flame Retardant XLPE Cable ZR-YJV 3×95mm²+1×50mm² for Site Power Wiring Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 3×95 mm² + 1×50 mm² Three phase cores of 95 mm² + one neutral ...
ZR-YJV 3x300mm²+1x150mm² XLPE Copper Cable 0.6/1kV Flame Retardant
ZR-YJV 3x300mm²+1x150mm² XLPE Copper Cable 0.6/1kV Flame Retardant Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 3×300 mm² + 1×150 mm² Three phase cores of 300 mm² + one neutral core of 150 mm² ...
ZR-YJV 1*50mm² Flame Retardant Cable, 0.6/1kV Pure Copper XLPE Insulation PVC Sheath for Power Wiring
ZR-YJV 1*50mm² Flame Retardant Cable, 0.6/1kV Pure Copper XLPE Insulation PVC Sheath for Power Wiring Code Mean:ZR-Flame Retardant, YJ-XLPE Insulation, V-PVC Outer Sheathed. ZR-YJV 1×50 mm² — Detailed Product Introduction ZR-YJV 1×50 is a flame-retardant, copper-conductor, XLPE-insulated, PVC...
ZR-YJV 3x240mm²+1x120mm² XLPE Copper Cable 0.6/1kV Flame Retardant
ZR-YJV 3x240mm²+1x120mm² XLPE Copper Cable 0.6/1kV Flame Retardant Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 3×240 mm² + 1×120 mm² Three phase cores of 240 mm² + one neutral core of 120 mm² ...