ZR-YJV 3x300mm²+1x150mm² XLPE Copper Cable 0.6/1kV Flame Retardant

ZR-YJV 3x300mm²+1x150mm² XLPE Copper Cable 0.6/1kV Flame Retardant

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
ZR-YJV 3x300mm²+1x150mm²

Trading Properties

moq
1 Meter
payment method
L/C,T/T
supply capacity
10000 meters per month

Product Summary

ZR-YJV 3x300mm²+1x150mm² XLPE Copper Cable 0.6/1kV Flame Retardant Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 3×300 mm² + 1×150 mm² Three phase cores of 300 mm² + one neutral core of 150 mm² ...

Product Details

Highlight:

zr-yjv copper xlpe cable

,

zr-yjv xlpe copper cable

,

1kv copper xlpe cable

Phase conductor (×3):
Bare Annealed Copper, Class 2 Stranded, 61×∅2.52 Mm, Conductor Ø ≈ 22.7–23.9 Mm Depending On Compaction
Neutral conductor (×1):
Bare Annealed Copper, Class 2 Stranded, 37×∅2.27 Mm, Conductor Ø ≈ 15.9–16.8 Mm Depending On Compaction
Phase conductor nominal area:
300 Mm²
Neutral conductor nominal area:
15 Mm²
Number of cores:
4 (3+1)
Phase conductor construction:
Class 2, 61×∅2.52 Mm,IEC 60228 / GB/T 3956
Neutral conductor construction:
Class 2, 37×∅2.27 Mm,IEC 60228 / GB/T 3956
Phase conductor diameter (approx.):
22.7–23.9 Mm
Neutral conductor diameter (approx.):
15.9–16.8 Mm
Insulation (×4):
XLPE
Phase insulation thickness:
1.8 Mm (300 Mm² Class)
Neutral insulation thickness:
1.4 Mm (150 Mm² Class)
Diameter over phase insulated core:
26.3–27.5 Mm
Diameter over neutral insulated core:
18.7–19.6 Mm
Filler / binder:
FR PP Filler + FR Tape
Outer sheath:
Flame-retardant PVC (ZR Grade)
Sheath thickness:
2.2 Mm
Overall cable diameter:
48.0 – 57.0 Mm
Design outer diameter:
≈ 52.0 Mm
Approx. weight:
3650 – 4450 Kg/km
Design weight:
≈ 3980 Kg/km
Cable shape:
Round

Product Description

ZR-YJV 3x300mm²+1x150mm² XLPE Copper Cable 0.6/1kV Flame Retardant

Cable Designation & Meaning

Code

Meaning

ZC

Flame retardant Class C 

YJ

Cross-linked polyethylene (XLPE) insulation 

V

Polyvinyl chloride (PVC) sheath 

3×300 mm² + 1×150 mm²

Three phase cores of 300 mm² + one neutral core of 150 mm² copper conductor


Construction: Three 300 mm² copper conductors (phase) + one 150 mm² copper conductor (neutral), XLPE insulation, PVC outer sheath. No metallic screen/armour as standard (can be added on request).


ZR-YJV 3x300mm²+1x150mm² XLPE Copper Cable 0.6/1kV Flame Retardant

ZC-YJV 3×300+1×150 mm² — Heavy LV Flame-Retardant 3+1 Feeder Cable — Specification

1. Overview & Ratings. ZC-YJV 3×300+1×150 is a heavy 3+1 LV main-feeder cable rated 0.6/1 kV (Um 1.2), 90 °C working, ZC class C PVC sheath: three 300 mm² compacted copper phase cores plus a reduced 150 mm² neutral, dry-cured XLPE, unarmored. OD ≈ 56 mm, ≈ 10800 kg/km (est.), ≈ 500 A per phase free air at 30 °C (est.). Scope: main switchgear incoming feeders, transformer LV secondary ties, heavy industrial main buses, large motor banks and plant risers — not 950°C fire duty.


2. Construction Stack (Inner → Outer, expanded).


Layer / Feature Build Function
Phase conductors L1/L2/L3 3×300 compacted Cu, Class 2, ≈61 strands R ≤0.0601 Ω/km
Neutral N 1×150 compacted Cu, Class 2, ≈37 strands R ≤0.124 Ω/km
Strand compaction Concentric layers rolled compact per core Compact heavy bundle, clean lugs
XLPE phase insulation Dry-cured PE, ≈2.8 mm Uniform 90°C dielectric
XLPE neutral insulation Dry-cured PE, ≈2.5 mm Matched to neutral voltage class
3+1 core laying Three large phases around the center neutral Heavy round finished bundle
PVC ZC sheath Class C, ≈2.6 mm overall Self-extinguishes, prints clear


3. Electrical Characteristics. Phase R ≤ 0.0601 Ω/km, neutral R ≤ 0.124 Ω/km @20 °C. Test 3.5 kV AC / 5 min; ≈ 500 A per phase (est., air 30 °C); short-circuit ≈ 33 kA / 1 s (est.); 50/60 Hz; unscreened; low-loss XLPE; high stable insulation resistance.

Insulation & Sheath Data

Property

Value

Insulation material

XLPE (cross-linked polyethylene)

Outer sheath material

PVC (ST₂)

Long-term service temp.

90 °C (continuous)

Max. conductor temp. (normal)

90 °C

Short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Test voltage AC (5 min)

3.5 kV

Dielectric strength

≥ 20 kV/mm

Volume resistivity @20 °C

≥ 1×10¹⁴ Ω·cm

Shield

None as standard (can be added)

Electrical Parameters

Parameter

Value

Note

Rated voltage U₀/U

0.6 / 1 kV

GB/T 12706.1 / IEC 60502-1

Max. system voltage

1.2 kV AC

—

Test voltage AC (5 min)

3.5 kV

Routine test

DC resistance @20 °C (phase)

≤ 0.0601 Ω/km per core

GB/T 3956 Class 2 Cu max (300 mm²)

DC resistance @20 °C (neutral)

≤ 0.124 Ω/km per core

GB/T 3956 Class 2 Cu max (150 mm²)

AC resistance @90 °C (est., phase)

≈ 0.077 Ω/km per core

—

AC resistance @90 °C (est., neutral)

≈ 0.159 Ω/km per core

—

Current rating in air (30 °C)

3-phase: 530 A​

3×300+1×150, touching, in free air

Current rating in tray (30 °C)

3-phase: 575 A​

3×300+1×150, spaced 2×OD

Current rating buried in ground (20 °C, thermal resistivity 1.2 K·m/W)

3-phase: 550 A​

direct buried

Current rating in conduit (30 °C)

3-phase: 475 A​

—

Short-circuit current (1 s, Cu, 250 °C, phase)

≈ 33.0 kA (33,000 A) per core

—

Short-circuit current (1 s, Cu, 250 °C, neutral)

≈ 16.5 kA (16,500 A) per core

—

Capacitance (core-to-sheath, approx.)

≈ 0.30 µF/km

XLPE

Inductive reactance (approx.)

≈ 0.08 Ω/km

at 50 Hz

Frequency

50/60 Hz AC

—


Reference values: 3×300+1×150 at 530 A three-phase, 400 V → max load ≈ 318 kW​ (cos φ = 0.8). Suitable for ultra-heavy three-phase distribution with reduced neutral, heavy industrial plants, and main incoming feeders.


4. Thermal & Flame. 90 °C continuous, 250 °C short-time; ZC class C self-extinguishing — flame retardancy, not 950°C integrity; withstands heavy load cycling; indoor switchgear preferred, UV jacket optional for exposed risers.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

90 °C (continuous)

Max. short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Min. installation ambient temp.

0 °C (below 0 °C requires preheating)

Service ambient range

−20 °C to +90 °C

Flexing temp. range

0 °C to +90 °C

Fire Performance (ZC-YJV — Flame Retardant C)

Property

Value / Requirement

Flame retardant

GB/T 18380.12 / IEC 60332-1-2​ (single cable, self-extinguishing)

Flame retardant class

Class C​ (ZC) per GB/T 19666

Halogen content

Contains halogen (PVC sheath)

Smoke density

Not low-smoke (PVC)

Corrosivity

Corrosive (PVC)

Toxicity

Toxic fumes when burned (PVC)

EMI shielding

None (no metallic screen/armour)


5. Installation Practice & Handling. Hydraulic crimp 300 mm² phase lugs and a 150 mm² neutral lug, heavy glands to ≈56 mm OD, torque per table; bend ≥ 15×OD ≈ 840 mm on large sheaves; apply bus-duct/tray derating; keep the heavy bundle round; verify three-phase continuity, phase sequence, neutral and insulation at the switchgear before energizing.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 15 × OD → ≈ 735 mm at Ø49.0 mm

four-core unarmoured

Max. pulling tension (phase)

4,500 N per core (300 mm² × 15 N/mm²)

Cu conductor limit

Max. pulling tension (neutral)

2,250 N per core (150 mm² × 15 N/mm²)

Cu conductor limit

Direct burial

Suitable (with sand bedding)

—

Surface mounting

Heavy-duty cable tray, ladder, cleats

—

Conduit ID

≥ 100 mm

—

Fixing

heavy-duty cleats, cable ties

—

Impact resistance

Moderate

—

Water resistance

Good (PVC sheath)

—

UV resistance

Fair (PVC degrades outdoors, use UV-resistant PVC or conduit)

—

Flex life

Good (Class 2 stranded)

fixed installation

Termination note

Standard compression lugs or mechanical connectors

—


6. Typical Service Applications. Main switchgear incoming feeders, transformer LV secondary ties, heavy industrial main buses, large motor banks, and vertical plant risers.


ZR-YJV 3x300mm²+1x150mm² XLPE Copper Cable 0.6/1kV Flame Retardant


7. Testing & QA Regime (16 items). Routine: phase and neutral DC resistance, 3.5 kV withstand, insulation resistance, continuity, phase/neutral insulation thickness, sheath thickness, dimensional check, strand construction, eccentricity, print legibility, mass, packing inspection. Type: ZC flame test, short-circuit rating, sheath mechanical.


Cable Parameters


ZR-YJV 3×300+1×150 mm² — Full Parameter Sheet
Flame-retardant 3+1-core CU/XLPE/PVC power cable · 0.6/1 kV · GB/T 12706.1 / IEC 60502-1 · finished Ø ≈ 57 mm · ≈ 11155 kg/km (Cu) — Beijing Jiaotai Cable sample basis
Section Parameter Value Unit Remarks / Standard
01 · Identification

Cable type ZR-YJV — Flame-retardant, Cu conductor, XLPE insulation, PVC sheath

Rated voltage (U0/U) 0.6/1 kV AC 50 Hz; maximum system voltage Um = 1.2 kV

Rated cross-sectional areas 3 × 300 (phase) + 1 × 150 (neutral) mm² 3+1 core configuration, reduced neutral

Conductor material Annealed copper (Cu) — Class 2 compact stranded per GB/T 3956 / IEC 60228

Insulation material Cross-linked polyethylene (XLPE) — 90 °C continuous rating

Sheath material Flame-retardant PVC, ST2 compound — Black; halogen-bearing

Flame-retardant class ZC (ZR) — Per GB/T 19666; ZA/ZB available on request

Standard reference GB/T 12706.1 / IEC 60502-1 — 0.6/1 kV extruded-insulation power cables
02 · Conductor

Phase stranding (×3) 61 × 2.52 mm (61/2.52) — 1+6+12+18+24 compact layout; 300 mm² each

Neutral stranding (×1) 37 × 2.25 mm (37/2.25) — 1+6+12+18 compact layout; 150 mm²

Phase conductor diameter ≈ 20.6 mm Compact strand-lay diameter (est.)

Neutral conductor diameter ≈ 15.8 mm Compact strand-lay diameter (est.)

Phase DC resistance @ 20 °C 0.0601 Ω/km Maximum per GB/T 3956 Class 2

Neutral DC resistance @ 20 °C 0.124 Ω/km Maximum per GB/T 3956 Class 2

Phase DC resistance @ 90 °C ≈ 0.0766 Ω/km Temperature-corrected (est.)

Copper mass — phase (per core) ≈ 2667 kg/km 300 mm² × 8.89 g/cm³

Copper mass — neutral ≈ 1334 kg/km 150 mm² × 8.89 g/cm³

Total copper mass ≈ 9335 kg/km 3 × 2667 + 1334
03 · Insulation

Phase insulation thickness 1.8 mm GB/T 12706.1 specified for 300 mm²

Neutral insulation thickness 1.4 mm GB/T 12706.1 specified for 150 mm²

Phase core Ø over insulation ≈ 24.2 mm 20.6 + 2 × 1.8

Neutral core Ø over insulation ≈ 18.6 mm 15.8 + 2 × 1.4

Insulation material XLPE — Cross-linked polyethylene

XLPE volume resistivity ≥ 1×10¹² Ω·cm At 20 °C

XLPE tensile strength ≥ 12.5 MPa Type test

XLPE elongation at break ≥ 200 % Type test

XLPE hot-set (200 °C, 15 min, 0.2 MPa) ≤ 175 / ≤ 15 % / % Load elongation / permanent set

Total XLPE mass ≈ 470 kg/km 3 phase + 1 neutral (est.)
04 · Assembly

Core arrangement Neutral at centre + 3 phase cores around — 3+1 triangular lay-up

Filler material Polypropylene (PP) rope — Fills interstices between cores

Binder tape Polyester non-woven tape — Holds assembled cores

Assembled core Ø ≈ 50.8 mm Derived: 57 − 2 × 3.1 sheath

Lay-up direction Right-hand (S) — Standard multi-core convention
05 · Sheath

Sheath material Flame-retardant PVC, ST2 — Black, halogen-bearing

Sheath thickness 3.1 mm Per GB/T 12706.1 for ≈ 51 mm assembled Ø

Overall finished diameter ≈ 57.0 mm Beijing Jiaotai Cable 3+1 sample

Approximate cable mass (Cu) ≈ 11155 kg/km Beijing Jiaotai Cable data

Approximate cable mass (Al) ≈ 4440 kg/km YJLV equivalent (Beijing Jiaotai)

PVC tensile strength ≥ 10 MPa Type test

PVC elongation at break ≥ 125 % Type test

PVC thermal stability ≥ 200 min @ 200 °C (HCl evolution)

Mass per 100 m (Cu) ≈ 1116 kg/100 m For drum loading estimation
06 · Electrical

Rated voltage U0/U 0.6/1 kV AC 50 Hz

Maximum system voltage Um 1.2 kV —

Phase DC resistance @ 20 °C ≤ 0.0601 Ω/km GB/T 3956 Class 2

Neutral DC resistance @ 20 °C ≤ 0.124 Ω/km GB/T 3956 Class 2

AC impedance @ 50 Hz ≈ 0.10 Ω/km √(R² + X²); R-dominant (est.)

Capacitance (typical) ≤ 0.42 μF/km Per phase core (est.)

Inductance (typical) ≈ 0.22 mH/km Three-core cable (est.)

Insulation resistance @ 90 °C ≥ 36.7 MΩ·km Finished cable, minimum

Routine test voltage 3.5 kV AC / 5 min — Power-frequency withstand, no breakdown

Site commissioning test DC 2.4 kV / 15 min — 4U0 per Q/GDW 13244.1-2018

Air ampacity @ 25 °C ≈ 570 A 3 phase loaded, Cu (Beijing Jiaotai)

Buried ampacity @ 25 °C ≈ 445 A 3 phase loaded, Cu (Beijing Jiaotai)

Short-circuit current (1 s) ≈ 34.5 kA Phase: I = k·A/√t, k=115 for Cu/XLPE
07 · Thermal

Max continuous conductor temp. 90 °C XLPE rated

Max short-circuit temp. (≤ 5 s) 250 °C XLPE limit

Min ambient temp. (service) −20 °C —

Max ambient temp. (service) +45 °C —

Min laying temperature 0 °C Warm drums below 0 °C

Max burial soil temp. 25 °C Reference for ampacity

Thermal coefficient of resistance (Cu) 0.00393 1/°C At 20 °C reference
08 · Fire (ZR)

Flame-retardant class ZC — GB/T 19666 default for ZR marking

Single-cable flame test GB/T 18380.12 — Equivalent IEC 60332-1-2

Bunched flame test GB/T 18380.35 category C — Char height ≤ 2.5 m

Halogen content Halogen-bearing (PVC) — Specify WDZ-YJY for LSZH

Smoke emission Emits smoke under fire — PVC jacket; LSZH alternative available
09 · Installation

Min bending radius (multi-core) ≥ 15 × OD ≈ 855 mm OD = actual finished diameter

Max pulling tension ≤ 12000 N 40 N/mm² of main phase core area (est.)

Recommended drum flange Ø ≥ 2000 mm For this section

Laying methods Conduit, tray, trench, duct, trunking, direct burial — Indoor or sheltered outdoor

Direct burial note Use armoured ZR-YJV22 without added protection — Unarmoured YJV needs conduit/protection

Termination Crimp lugs + heat-shrink or cold-shrink kits — Size for 20.6 mm phase / 15.8 mm neutral core
10 · Packing

Standard supply length 100 m/coil or drum Custom lengths available

Drum type Wooden drum (≥ Ø 2000 mm flange) — Sealed until installation

Surface marking Type, voltage, manufacturer, year, metre marks — Per GB/T 6995

Storage conditions Dry, covered, −20 to +45 °C — Away from sunlight, moisture, oils, sharp objects

Transport Drums secured against rolling and impact — Do not drag cable over rough ground


Cable Test Parameters


Test Parameters — ZR-YJV 3×300+1×150 mm²
No. Test Item Test Condition / Method Requirement Type
1 Conductor DC resistance GB/T 3048.4, 20 °C Phase ≤ 0.0601 Ω/km; Neutral ≤ 0.124 Ω/km Routine
2 Power-frequency withstand 3.5 kV AC, 5 min No breakdown Routine
3 Insulation resistance GB/T 3048.5, 90 °C ≥ 36.7 MΩ·km Routine
4 Conductor continuity Visual + electrical All cores continuous Routine
5 Dimensional check Micrometer Phase ins. ≥ 1.8 mm; neutral ≥ 1.4 mm; sheath ≥ 3.1 mm; OD ≈ 57 mm Routine
6 XLPE hot-set test 200 ± 3 °C, 15 min, 0.2 MPa Load elongation ≤ 175 %; permanent set ≤ 15 % Type
7 XLPE tensile & elongation GB/T 2951.11 Tensile ≥ 12.5 MPa; elongation ≥ 200 % Type
8 PVC sheath tensile & elongation GB/T 2951.11 Tensile ≥ 10 MPa; elongation ≥ 125 % Type
9 PVC thermal stability 200 °C, HCl evolution ≥ 200 min Type
10 Single-cable vertical flame GB/T 18380.12 Self-extinguishing; char ≤ 50 mm above burner Type
11 Bunched cable flame (cat. C) GB/T 18380.35 Char height ≤ 2.5 m Type
12 Bending test ≥ 15 × OD mandrel No crack in insulation or sheath Type
13 Heat deformation (PVC) 80 °C, 4 h, load Deformation ≤ 50 % Type
14 XLPE shrinkage test 130 °C, 1 h Shrinkage ≤ 4 % Type
15 Site DC withstand 4U0 = 2.4 kV DC, 15 min No breakdown (Q/GDW 13244.1-2018) Site
16 Phase/neutral identification Visual + continuity Correct core identification and sequence Site


Cable Cross Section Structure


ZR-YJV 3x300mm²+1x150mm² XLPE Copper Cable 0.6/1kV Flame Retardant



Cable Construction Description


Construction Description — ZR-YJV 3×300+1×150 mm²
Layer-by-layer build-up narrative, conductor through outer jacket · per GB/T 12706.1 & IEC 60502-1 · CU / XLPE / PVC · 0.6/1 kV class · finished Ø ≈ 57 mm (Beijing Jiaotai Cable sample)
1. Product Identity & Ratings
ZR-YJV 3×300+1×150 represents the upper end of the standard flame-retardant 3+1-core low-voltage range: three 300 mm² copper phase conductors paired with a single 150 mm² copper neutral, all XLPE-insulated and enclosed in one ST2 PVC jacket for 0.6/1 kV service. It is produced and type-tested to GB/T 12706.1 / IEC 60502-1, stranded to GB/T 3956, and carries the ZR marking corresponding to class ZC under GB/T 19666. The finished cable measures about 57 mm across (Beijing Jiaotai Cable sample) and weighs approximately 11155 kg per kilometre in copper (4440 kg/km for the aluminium YJLV equivalent); standard supply is 100 m coils or wooden drums with ≥ Ø 2000 mm flanges (≈ 1116 kg per 100 m).
The 3+1 arrangement follows the conventional three-phase four-wire format: the reduced neutral core sits at the centre while the three phase cores are laid up around it. With all three phase cores energised, the cable supports a reference current of about 570 A in free air at 25 °C and 445 A when directly buried at 25 °C (Beijing Jiaotai Cable data) — suited to the heaviest main switchgear incomers, large transformer secondaries and high-capacity industrial feeders.
2. Copper Stranded Conductors
Each 300 mm² phase core is formed from sixty-one 2.52 mm annealed wires in the 1+6+12+18+24 compact arrangement (61/2.52) — the Class 2 standard for this cross-section — giving a strand-lay diameter of about 20.6 mm and a DC resistance ceiling of 0.0601 Ω/km at 20 °C (about 0.0766 Ω/km at the 90 °C operating point). The 150 mm² neutral core uses thirty-seven 2.25 mm wires (37/2.25, 1+6+12+18) to about 15.8 mm strand-lay Ø, with resistance capped at 0.124 Ω/km. Copper mass alone is about 2667 kg/km per phase core and 1334 kg/km for the neutral; the five-ring 61-wire phase construction keeps the large-section core compact yet flexible enough for drum handling and crimp lug termination.
3. XLPE Dielectric Insulation
XLPE is extruded at 1.8 mm onto the phase cores (the GB/T 12706.1 specified value for 300 mm²) and at 1.4 mm onto the 150 mm² neutral core — producing approximately 24.2 mm per phase core and 18.6 mm for the neutral core over the insulation. The dielectric is rated for 90 °C continuous duty and 250 °C for five seconds, maintains volume resistivity above 1×10¹² Ω·cm, passes the routine 3.5 kV AC five-minute voltage proof, and offers tensile strength ≥ 12.5 MPa with elongation ≥ 200 %. Total XLPE mass is about 470 kg/km.
4. Cabling & PVC Outer Jacket
After insulation, the neutral core is placed at the centre and the three phase cores are cabled around it in a triangular ring with polypropylene filler and a polyester binder tape, forming a bundle of about 50.8 mm diameter (derived from the finished size). A 3.1 mm layer of flame-retarded ST2 PVC is then extruded over the assembly to the ≈ 57 mm finish. The jacket provides ZC behaviour through GB/T 18380.12 and GB/T 18380.35, offers tensile strength ≥ 10 MPa and elongation ≥ 125 %; because PVC is halogenated, low-smoke zero-halogen projects should specify WDZ-YJY, and direct-burial projects without added protection should specify steel-tape armoured ZR-YJV22 (≈ 65–70 mm OD).
5. Site Handling & Operational Notes
• Observe the 15 × OD minimum bending radius (≈ 855 mm).  • Perform the DC 4U0 = 2.4 kV / 15 min commissioning test before first energisation.  • Service ambient spans −20 to +45 °C; warm drums below 0 °C before pulling.  • Derate the 570 A (air) / 445 A (buried) references for ambient temperature, grouping and soil conditions.  • Maximum pulling tension ≤ 12000 N; use appropriate pulling grips and lubricant.  • Select lugs and glands matched to the 20.6 mm phase core, 15.8 mm neutral core and ≈ 57 mm jacket.  • Short-circuit rating ≈ 34.5 kA for 1 s on the phase (≈ 17.3 kA basis on the neutral) — verify against protective device settings.  • Use drums with ≥ Ø 2000 mm flanges (≈ 1116 kg per 100 m).


8. Factory Advantages.

  • Heavy 3+1 main-feeder sizing — reduced 150 neutral avoids excess copper on balanced heavy main loads while phases carry full duty.
  • Stable XLPE cure on large cores — even cross-linking keeps the 90°C dielectric consistent under sustained high-current load.
  • Dosed ZC compound — self-extinguishing jacket protects switchgear rooms and main cable basements.
  • Length-on-demand — cut to exact feeder meter with sealed ends.
  • Dual-section resistance log — phase 300 and neutral 150 R recorded to lot for traceability.
  • Continuous print line — type, size, ZC, voltage and length readable along main-feeder runs.
  • Phase-color option — L1/L2/L3/N colors reduce wiring errors at switchboards.
  • Heavy drum pack — structurally rated drum with moisture-sealed ends for ocean shipment.
  • Certified QA pack — routine + type test record supports witness testing and commissioning.

ZR-YJV 3x300mm²+1x150mm² XLPE Copper Cable 0.6/1kV Flame Retardant


9. Packaging, Storage & Logistics. Cut to measured main-feeder length on a heavy wooden drum with sealed ends; continuous marking; store dry indoor on strong drum supports, shaded, avoid direct UV.


ZR-YJV 3x300mm²+1x150mm² XLPE Copper Cable 0.6/1kV Flame Retardant


10. Procurement Specification. State "ZC-YJV 3×300+1×150", length, class C, phase colors; note the reduced neutral suits balanced loads (enlarge for high harmonics) and not fire-rated; request the dual-section resistance log and 16-item QA record. Est. values confirmed against the factory certificate.


11. Cable Industry FAQ.

  • Q1: How does 3×300+1×150 differ from 4×70? A heavy main-feeder 3+1 build rather than a small four-core branch: phases 300 vs 70 mm², neutral 150 vs 70; OD 56 vs 26 mm, mass 10800 vs 3300 kg/km, phase current 500 vs 175 A, phase R 0.0601 vs 0.268 Ω/km; built for switchgear feeders and transformer ties rather than mid-heavy branches.
  • Q2: Why a 150 mm² neutral? Balanced main and motor loads draw little neutral current; a reduced neutral saves copper. Enlarge it where VFD/rectifier harmonics are high.
  • Q3: Is ZC fire-resistant? No. Class C self-extinguishes; it does not hold live at 950°C/180min.
  • Q4: DC resistance values? 300 phases ≤0.0601; 150 neutral ≤0.124 Ω/km at 20°C.
  • Q5: Screen or armor? Unscreened standard; add braid near VFD EMI; steel-tape/wire armor for buried heavy-duty ducts.
  • Q6: Current per phase? ≈500 A (est.) free air 30°C; derate in bus ducts and crowded trays.
  • Q7: Bending? ≈840 mm (15×OD); use large sheaves and pulling equipment on this heavy section.
  • Q8: Connectors? 300 mm² phase lugs and a 150 mm² neutral lug; heavy gland to ≈56 mm OD.
  • Q9: Indoor or outdoor? Indoor switchgear preferred; specify UV-stabilized jacket for exposed risers.
  • Q10: Packing? Heavy wooden drum with moisture-sealed ends.
  • Q11: What proof ships? Dual-section resistance log + 16-test record; est. values confirmed against certificate.