- 63 Items Found
Quality 1x120mm2 Single Core Cable Full Gauge Pure Copper Anti Aging Flame Retardant Power factory

1x120mm2 Single Core Cable Full Gauge Pure Copper Anti Aging Flame Retardant Power

ZR-YJV 1*120mm² Single Core Cable Full Gauge Pure Copper Anti Aging Flame Retardant Powe Cable Designation & Meaning Code Meaning ZC Flame retardant C— IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 1×120 mm² Single core, 120 mm² copper conductor Construction ...

Quality Copper 4 Cores Cable 3x10mm² + 1x6mm2 For Three Phase Power Wiring factory

Copper 4 Cores Cable 3x10mm² + 1x6mm2 For Three Phase Power Wiring

3+1 Core ZR-YJV Flame Retardant Copper Cable 3x10mm²+1x6mm² for Three Phase Power Wiring Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer ...

Quality 3+1 Core Flame Retardant 4 Cores Cable  For Factory Three Phase Main Power factory

3+1 Core Flame Retardant 4 Cores Cable For Factory Three Phase Main Power

ZR-YJV 3+1 Core Flame Retardant Copper Cable 3x16mm²+1x10mm² for Factory Three-Phase Main Power Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC ...

Quality 3×120mm2+1×70mm2 4 Cores Cable Power Distribution Flame Retardant XLPE Insulated Copper factory

3×120mm2+1×70mm2 4 Cores Cable Power Distribution Flame Retardant XLPE Insulated Copper

Power Distribution Cable ZR-YJV 3×120mm²+1×70mm², Flame Retardant XLPE Insulated Copper Wire Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer ...

Quality 1 X 70mm2 Single Core Cable Solid Copper XLPE Insulation PVC Jacket For Building Power factory

1 X 70mm2 Single Core Cable Solid Copper XLPE Insulation PVC Jacket For Building Power

ZR-YJV 1*70mm² Single Conductor , 0.6/1kV Solid Copper, XLPE Insulation PVC Jacket for Building Power Cable Designation & Meaning Code Meaning ZC Flame retardant C— IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 1×70 mm² Single core, 70 mm² copper conductor ...

Quality Class 2 x 25mm2 2 Cores Cable Flame Retardant Copper Cable Xlpe Insulation Pvc Sheath factory

Class 2 x 25mm2 2 Cores Cable Flame Retardant Copper Cable Xlpe Insulation Pvc Sheath

ZR-YJV 2*25mm² Flame Retardant Copper Cable,0.6/1kV XLPE Insulation PVC Sheath for Power Distribution Cable Designation & Meaning Code Meaning ZC Flame retardant C— IEC 60332-3-24, Category C YJ Cross-linked polyethylene (XLPE) insulation V PVC sheath 2×25 mm² Two cores, 25 mm² copper conductor each ...

Quality 3x25mm2+1x16mm2 25 Sq Mm 4 Core Cable For Three Phase Retrofit Projects factory

3x25mm2+1x16mm2 25 Sq Mm 4 Core Cable For Three Phase Retrofit Projects

Flame Retardant 3+1 Core Copper Cable ZR-YJV 3x25mm²+1x16mm² for Three Phase Retrofit Projects Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 3×25 mm² + 1×16 mm² Three phase cores of 25 mm² + one ...

Quality Flame Retardant XLPE Cable 4+1 Core 4×185mm²+1*95mm² ZR-YJV Copper 0.6/1kV factory

Flame Retardant XLPE Cable 4+1 Core 4×185mm²+1*95mm² ZR-YJV Copper 0.6/1kV

Flame Retardant XLPE Cable 4+1 Core 4×185mm²+1*95mm² ZR-YJV Copper 0.6/1kV Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×185 mm² + 1×95 mm² Four cores of 185 mm² (3 phase + 1 neutral) + one earth ...

Quality Fire Alarm Multi Core Cable 5 Core 1.5m2 RVV For Emergency System factory

Fire Alarm Multi Core Cable 5 Core 1.5m2 RVV For Emergency System

Fire Alarm Multi Core Cable 5 Core 1.5mm² RVV for Emergency System Cable Designation & Meaning Code Meaning RVV R = Flexible copper conductor (Class 5), V = PVC insulation, V = PVC sheath 300/500 V Rated voltage U₀/U = 300/500 V; Uₘ = 500 V 5×1.5 mm² Five flexible cores, each 1.5 mm² copper ...