ZR-YJV 1*50mm² Flame Retardant Cable, 0.6/1kV Pure Copper XLPE Insulation PVC Sheath for Power Wiring

ZR-YJV 1*50mm² Flame Retardant Cable, 0.6/1kV Pure Copper XLPE Insulation PVC Sheath for Power Wiring

Basic Properties

country of origin
China
brand name
TD
certificate
CE/ISO/CCC
product model
ZR-YJV 1*50mm²

Trading Properties

moq
100 meters
payment method
L/C,T/T
supply capacity
100000 meters per month

Product Summary

ZR-YJV 1*50mm² Flame Retardant Cable, 0.6/1kV Pure Copper XLPE Insulation PVC Sheath for Power Wiring Code Mean:ZR-Flame Retardant, YJ-XLPE Insulation, V-PVC Outer Sheathed. ZR-YJV 1×50 mm² — Detailed Product Introduction ZR-YJV 1×50 is a flame-retardant, copper-conductor, XLPE-insulated, PVC...

Product Details

Conductor:
Bare Annealed Copper, Class 2 Stranded Circular, 19×∅1.87 Mm​ (typical), Conductor Ø ≈ 9.3 Mm
Conductor nominal area:
50 Mm²
Conductor construction:
Class 2, 19×∅1.87 Mm​ Min. 19 Wires Per GB/T 3956 (>35 Mm²)
Conductor diameter (approx.):
9.3 Mm
Insulation:
XLPE Compound, Extruded
Insulation thickness (nominal):
1.0mm,50 Mm² Class
Diameter over insulation (approx.):
11.3 Mm 9.3 + 2×1.0
Filler / binder:
Flame-retardant (FR) Non-hygroscopic Tape / PP Mesh
Outer sheath​:
Polyolefin (PO) Compound, Flame-retardant Grade (ZR)​ — Halogen-free Base, Not Low-smoke-certified
Sheath nominal thickness:
1.4 Mm​ Single-core (some Makers 1.5)
Overall cable diameter:
14.8 – 15.8 Mm
Approx. weight:
480 – 530 Kg/km
Long-term service temperature:
90 °C
Short-circuit temperature (≤5 s):
250 °C
Emergency overload:
105–130 °C
Routine test:
3.5 KV AC / 5 Min; Type Test 4.0 KV
Volume resistivity @90 °C:
≥ 10¹² Ω·cm
Insulation resistance constant:
≈ 3.67 MΩ·km @90 °C

Product Description

ZR-YJV 1*50mm² Flame Retardant Cable, 0.6/1kV Pure Copper XLPE Insulation PVC Sheath for Power Wiring


Code Mean:ZR-Flame Retardant, YJ-XLPE Insulation, V-PVC Outer Sheathed.


ZR-YJV 1×50 mm² — Detailed Product Introduction

ZR-YJV 1×50 is a flame-retardant, copper-conductor, XLPE-insulated, PVC-sheathed power cable for 0.6/1 kV distribution, designed and tested to GB/T 12706.1 and IEC 60502-1.

1. Product Structure (from conductor to outer sheath)

No. Layer Material / Construction Key data
1 Conductor (Cu) Plain annealed copper, Class 1/2 (typical Class 2 stranded), nominal 50 mm² Typical stranding 10 × 2.52 mm (10/2.52; also 19 × 1.83 mm); Ø ≈ 8.3 mm (8.3–9.2 mm); max. DC resistance ≤ 0.387 Ω/km @ 20 °C (GB/T 3956)
2 Insulation (XLPE) Cross-linked polyethylene (thermoset) Nominal thickness 1.0 mm; Ø over insulation ≈ 10.3 mm; 90 °C continuous rating
3 Outer sheath (PVC) Flame-retardant PVC, ST2 type, black Nominal thickness 1.4 mm; overall Ø ≈ 13.2–13.5 mm; flame retardance ZC (ZR)

Overall diameter ≈ 13.5 mm (13.2–13.5 mm) and weight ≈ 466 kg/km (458–466 kg/km).


2. Product Performance

  • Electrical: Conductor DC resistance ≤ 0.387 Ω/km @ 20 °C; routine AC withstand test 3.5 kV / 5 min without breakdown; finished-cable insulation resistance ≥ 36.7 MΩ·km @ 20 °C (typical reference); XLPE volume resistivity ≥ 1×10¹² Ω·cm; capacitance ≤ 0.45 μF/km.
  • Thermal: Max. continuous conductor temperature 90 °C; short-circuit (≤ 5 s) 250 °C; ambient service −20 to +45 °C; laying temperature not below 0 °C.
  • Flame retardance: "ZR" = flame-retardant, default class ZC per GB/T 19666; passes single-cable vertical flame test (GB/T 18380.12) and class-C bunched test (GB/T 18380.35: ≥ 1.5 L/m non-metallic volume, 20 min flame, char extent ≤ 2.5 m).
  • Ampacity (reference): ≈ 235 A in air (single core, 30 °C); direct burial ≈ 200–240 A depending on soil thermal resistivity — always apply correction factors per GB/T 16895 / IEC 60364.
  • Mechanical/installation: min. bending radius 20 × OD (single-core); site DC withstand test after installation 4U0 = 2.4 kV / 15 min (per Q/GDW 13244.1-2018 practice).

ZR-YJV 1*50mm² Flame Retardant Cable, 0.6/1kV Pure Copper XLPE Insulation PVC Sheath for Power Wiring


3. Key Parameters

  • Rated voltage 0.6/1 kV (Um = 1.2 kV); 50 Hz; single core; 50 mm²
  • Conductor: Cu Class 2, 10 × 2.52 mm, Ø ≈ 8.3 mm; DC R ≤ 0.387 Ω/km
  • Insulation: XLPE, 1.0 mm; Sheath: flame-retardant PVC ST2, 1.4 mm
  • Weight ≈ 466 kg/km; OD ≈ 13.5 mm; length 100 m per coil/drum
ZR-YJV 1×50 mm² Flame-Retardant Copper-Conductor XLPE-Insulated PVC-Sheathed Power Cable — Product Parameters (0.6/1 kV)
Construction: CU / XLPE / PVC  •  Standards: GB/T 12706.1, IEC 60502-1 (cable), GB/T 3956 (conductor), GB/T 19666 & GB/T 18380 (flame retardance)  •  Nominal values for reference — confirm against factory test certificate
No. Category Parameter Value Unit Notes / Standard Reference
A. Product Identification
1 Identification Product name Flame-retardant copper-conductor XLPE-insulated PVC-sheathed power cable — Designation ZR-YJV; "ZR" = flame-retardant (halogen-containing)
2 Identification Model designation ZR-YJV 1×50 — Cu / XLPE / PVC
3 Identification Design standards GB/T 12706.1; IEC 60502-1 — Conductor: GB/T 3956 / IEC 60228; flame retardance: GB/T 19666, GB/T 18380; safety: CCC / production licence
4 Identification Rated voltage U0/U 0.6/1 kV Max system voltage Um = 1.2 kV
5 Identification Rated frequency 50 Hz AC power distribution
6 Identification Number of cores 1 — Single-core cable
7 Identification Nominal cross-sectional area 50 mm² Nominal conductor cross-section per GB/T 3956
B. Cable Construction (from conductor to outer sheath)
8 Conductor Material Plain annealed copper (Cu) — High-conductivity electrolytic / oxygen-free copper
9 Conductor Conductor class Class 1 or Class 2 (typical: Class 2, stranded) — GB/T 3956 / IEC 60228
10 Conductor Typical stranding construction 10 wires × 2.52 mm (10/2.52); also 19 × 1.83 mm — Class 2 round stranded; nominal section ≈ 50 mm²
11 Conductor Conductor diameter ≈ 8.3 mm 8.3–9.2 mm per manufacturer tables (Qifan 8.3 mm)
12 Conductor Max. DC resistance of conductor at 20 °C 0.387 Ω/km GB/T 3956, Class 2 copper; acceptance criterion for 50 mm²
13 Insulation Material Cross-linked polyethylene (XLPE) — Thermally cross-linked; natural/transparent colour
14 Insulation Nominal insulation thickness 1.0 mm GB/T 12706.1 / IEC 60502-1 (0.6/1 kV, 50 mm²)
15 Insulation Diameter over insulation ≈ 10.3 mm ≈ 8.3 + 2 × 1.0 (calculated)
16 Sheath Material Flame-retardant polyvinyl chloride (PVC, ST2 type) — Colour: black (or as ordered)
17 Sheath Nominal sheath thickness 1.4 mm GB/T 12706.1 / IEC 60502-1
18 Dimensions Approx. overall diameter 13.2–13.5 mm Qifan 13.5 mm; Weiguang 13.2 mm
19 Dimensions Approx. cable weight ≈ 466 kg/km Range 458–466 kg/km across manufacturers (Qifan 466; Weiguang 458)
C. Electrical Performance
20 Electrical Max. DC conductor resistance at 20 °C 0.387 Ω/km GB/T 3956; routine measurement
21 Electrical Power-frequency withstand voltage (routine test) 3.5 kV / 5 min, no breakdown — AC 50 Hz; per GB/T 12706.1 / IEC 60502-1
22 Electrical Insulation resistance (finished cable, 20 °C) ≥ 36.7 MΩ·km Typical finished-cable requirement for 0.6/1 kV XLPE cables; varies with geometry and manufacturer test method
23 Electrical XLPE volume resistivity at 20 °C ≥ 1 × 10¹² Ω·cm Material-level requirement (manufacturer reference)
24 Electrical Capacitance (single-core, approx.) ≤ 0.45 μF/km Manufacturer reference value
25 Electrical Reference ampacity — in air, 30 °C, single core ≈ 235 A Reference value (Guangheng); depends on laying, grouping, ambient — apply correction factors per GB/T 16895 / IEC 60364
26 Electrical Reference ampacity — direct burial, 25 °C ≈ 200–240 A Reference value; depends on soil thermal resistivity and depth (reference range)
D. Thermal Performance
27 Thermal Max. continuous conductor temperature 90 °C XLPE insulation temperature class
28 Thermal Max. conductor temperature under short-circuit (≤ 5 s) 250 °C Per GB/T 12706.1 / IEC 60502-1
29 Thermal Ambient service temperature range -20 to +45 °C Per Qifan datasheet; check project specification
30 Thermal Min. installation (laying) temperature 0 °C Pre-heat the cable if ambient is below 0 °C
E. Flame Retardance (ZR)
31 Flame retardance Flame-retardant class ZC (class C) by default for "ZR" — GB/T 19666; ZA / ZB available on request; halogen-containing PVC (not LSZH)
32 Flame retardance Single-cable vertical flame-spread test Pass — GB/T 18380.12
33 Flame retardance Bunched flame-spread test (class C) Char extent ≤ 2.5 m above burner bottom edge — GB/T 18380.35: non-metallic volume ≥ 1.5 L/m; flame application 20 min
34 Flame retardance Halogen content Halogen-containing (PVC) — For low-smoke, zero-halogen requirement select WDZ-YJY (LSZH) type
F. Installation
35 Installation Min. bending radius — single-core cable 20 × OD — Qifan & Huaneng datasheets; some manufacturers specify 15 × OD; OD = actual cable diameter
36 Installation Laying methods Conduit, tray, cable trench, tunnel, duct, supported/suspended aerial — Also direct burial with mechanical protection where permitted
37 Installation Site withstand test after installation DC 4U0 = 2.4 kV, 15 min (recommended) — Per utility procurement standard Q/GDW 13244.1-2018; practice may vary by project
G. Packing & Delivery
38 Packing Standard delivery length 100 m per coil/drum (or as ordered) — Typical industry practice; custom lengths available
39 Packing Cable marking Model, rated voltage, manufacturer, year of manufacture, sequential length marks — Per GB/T 6995 / project specification
40 Packing Packing form Wooden drum / coil / export packing — As per customer requirement


4. Test Parameters

Routine: DC resistance ≤ 0.387 Ω/km; AC 3.5 kV/5 min; construction check. Sample: hot-set test on XLPE (200 ± 3 °C, 15 min, 0.2 MPa — elongation under load ≤ 175 %, permanent ≤ 15 %); conductor construction check (10 × 2.52 mm). Type: flame tests (GB/T 18380.12 / .35); bending test. Post-installation: DC 4U0 = 2.4 kV / 15 min.


ZR-YJV 1×50 mm² — Test / Verification Parameters (per GB/T 12706.1 & IEC 60502-1)
Test Stage Test Item Method / Standard Requirement / Acceptance Criterion Notes
Routine test Conductor DC resistance measurement GB/T 3956 (IEC 60228) ≤ 0.387 Ω/km at 20 °C Measured on every production length
Routine test Power-frequency withstand voltage GB/T 12706.1 / IEC 60502-1 3.5 kV AC, 5 min, no breakdown Applied between conductor and water/earth; 50 Hz
Routine test Construction check — insulation & sheath thickness, outer diameter GB/T 2951 Within GB/T 12706.1 tolerances Insulation ≥ 1.0 mm nominal; sheath ≥ 1.4 mm nominal
Sample test Hot set (thermal elongation) test — XLPE insulation GB/T 12706.1 §16.3.13 / GB/T 2951.11 200 ± 3 °C, 15 min, stress 0.2 MPa: elongation under load ≤ 175 %; permanent elongation after cooling ≤ 15 % Verifies degree of cross-linking
Sample test Conductor construction & diameter check GB/T 3956 Class 2; 10 × 2.52 mm; Ø ≈ 8.3 mm Sampled per batch
Type test Single-cable vertical flame-spread test (flame retardance) GB/T 18380.12 No flame spread; charring does not reach top reference point ZR / ZC flame-retardant property
Type test Bunched flame-spread test, class C GB/T 18380.35 Char extent ≤ 2.5 m above burner bottom edge; flame application 20 min; non-metallic volume ≥ 1.5 L/m Class ZC per GB/T 19666
Type test Bending test (mechanical) GB/T 12706.1 Bend around specified mandrel without insulation/sheath damage Mandrel diameter related to cable OD
Post-installation DC withstand test after installation Q/GDW 13244.1-2018 (recommended practice) 4U0 = 2.4 kV DC, 15 min, no breakdown For new installations; verify project specification
Optional Insulation resistance measurement at 20 °C Manufacturer test method ≥ 36.7 MΩ·km (typical finished-cable value) Not a routine item in GB/T 12706.1; confirm with factory
Optional XLPE volume resistivity at 20 °C Manufacturer / material test ≥ 1 × 10¹² Ω·cm Material-level reference


5.Cross Section Structure

ZR-YJV 1*50mm² Flame Retardant Cable, 0.6/1kV Pure Copper XLPE Insulation PVC Sheath for Power Wiring

ZR-YJV 1×50 mm² — Cable Cross-Section Structure (Schematic)
Layers from conductor to outer sheath · nominal values per GB/T 12706.1 / IEC 60502-1 · not to exact scale






No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductor (Cu) Annealed copper, Class 2 stranded — 10 × 2.52 mm (10/2.52), nominal 50 mm² — ≈ 8.3 (Ø) Current-carrying element; max DC resistance ≤ 0.387 Ω/km @ 20 °C
2 Insulation (XLPE) Cross-linked polyethylene 1 ≈ 10.3 (Ø over insulation) Dielectric barrier; rated 90 °C continuous; withstands 3.5 kV / 5 min
3 Outer sheath (PVC) Flame-retardant PVC, ST2 type, black 1.4 ≈ 13.5 (Ø overall) Mechanical & moisture protection; flame retardance ZC (ZR) per GB/T 19666












Key Dimensions & Properties
Overall diameter 13.2–13.5 mm Qifan 13.5 mm; Weiguang 13.2 mm

Approx. cable weight ≈ 466 kg/km Range 458–466 kg/km across manufacturers

Rated voltage 0.6/1 kV AC 50 Hz; max system voltage Um = 1.2 kV

Max conductor temperature 90 / 250 °C Continuous / short-circuit (≤ 5 s)

Min. bending radius (single-core) 20 × OD — OD = actual cable diameter

Flame-retardant class ZC (ZR) — GB/T 19666


6.Usage Precautions

  1. Install only when ambient ≥ 0 °C; pre-heat the cable if colder.
  2. Min. bending radius 20 × OD — avoid sharp bends and kinking.
  3. ZR-YJV contains halogen (PVC); for LSZH requirements choose WDZ-YJY.
  4. Ampacity must be derated for grouping, ambient temperature and burial conditions.
  5. Perform the site DC test only after verifying insulation integrity; avoid prolonged overvoltage.
  6. Store on drums/coils, away from direct sunlight and mechanical damage.

7. Application Range

Indoor/outdoor distribution and branch circuits at 0.6/1 kV in industrial plants, commercial buildings, residential complexes, substations and similar installations — in conduits, trays, trenches, tunnels and ducts; suitable where flame-retardant performance is required (not for direct sunlight exposure unless UV-protected).

ZR-YJV 1*50mm² Flame Retardant Cable, 0.6/1kV Pure Copper XLPE Insulation PVC Sheath for Power Wiring


8.Package


ZR-YJV 1*50mm² Flame Retardant Cable, 0.6/1kV Pure Copper XLPE Insulation PVC Sheath for Power Wiring


9.Factory Overview


ZR-YJV 1*50mm² Flame Retardant Cable, 0.6/1kV Pure Copper XLPE Insulation PVC Sheath for Power Wiring