logo
Anhui Tongdu International Trade Co., Ltd.
Online Service

Online Service

Contact Person
+86 19056002718
WeChat QR Code
Follow Us

ZR-YJV 4×25mm² Flame Retardant Copper Power Cable, 0.6/1kV XLPE Insulated PVC Sheath

ZR-YJV 4×25mm² Flame Retardant Copper Power Cable, 0.6/1kV XLPE Insulated PVC Sheath

Basic Properties

country of origin
China
brand name
TD
certificate
CE/ISO/CCC
product model
ZR-YJV 4×25mm²

Trading Properties

moq
100 meters
payment method
L/C,T/T
supply capacity
10000 meters per month

Product Summary

ZR-YJV 4×25mm² Flame Retardant Copper Power Cable, 0.6/1kV XLPE Insulated PVC Sheath Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×25 mm² Four equal cores of 25 mm² copper conductor Construction: ...

Product Details

Highlight:

zr-yjv 4 cores cable

,

zr-yjv 25 sq mm 4 core cable

,

copper 4 cores cable

Conductor (×4):
Bare Annealed Copper, Class 2 Stranded, 7×∅2.14 Mm, Conductor Ø ≈ 6.4 Mm
Conductor nominal area (per core):
25 Mm²
Number of cores:
4
Conductor construction:
Class 2, 7×∅2.14 Mm,min. 7 Wires
Conductor diameter (approx.):
6.4mm
Insulation (×4):
XLPE
Insulation thickness:
0.9 Mm (25 Mm² Class)
Diameter over insulated core:
8.2 Mm,6.4 + 2×0.9
Filler / binder:
FR PP Filler + FR Tape
Outer sheath:
Flame-retardant PVC (ZR Grade)
Sheath thickness:
1.8 Mm (multi-core Rule, ≥1.8 Mm)
Overall cable diameter:
20.5 – 22.0 Mm
Approx. weight:
620 – 700 Kg/km
Long-term service temp.:
90 °C
Short-circuit temp. (≤5 s):
250 °C
Emergency overload:
105–130 °C
Routine test:
3.5 KV AC / 5 Min; Type Test 4.0 KV
Volume resistivity @90 °C:
≥ 10¹² Ω·cm

Product Description

ZR-YJV 4×25mm² Flame Retardant Copper Power Cable, 0.6/1kV XLPE Insulated PVC Sheath

Cable Designation & Meaning

Code

Meaning

ZC

Flame retardant Class C

YJ

Cross-linked polyethylene (XLPE) insulation 

V

Polyvinyl chloride (PVC) sheath

4×25 mm²

Four equal cores of 25 mm² copper conductor


Construction: Four 25 mm² copper conductors (3 phase + 1 neutral), XLPE insulation, PVC outer sheath. No metallic screen/armour as standard (can be added on request).


ZR-YJV 4×25mm² Flame Retardant Copper Power Cable, 0.6/1kV XLPE Insulated PVC Sheath

ZC-YJV 4×25 mm² — LV Flame-Retardant Four-Core Power Cable — Specification

1. Overview & Ratings. ZC-YJV 4×25 is a four-core LV distribution cable rated 0.6/1 kV (Um 1.2), 90 °C working, ZC class C PVC sheath: four equal 25 mm² compacted copper cores (L1/L2/L3 phases plus a full-size neutral), dry-cured XLPE, unarmored (screen optional). OD ≈ 16 mm, ≈ 1350 kg/km (est.), ≈ 88 A per core free air at 30 °C (est.). Scope: 380/400 V three-phase socket groups, small-power feeders and mixed four-wire branches — not 950°C fire duty.


2. Construction Stack (Inner → Outer, expanded).


Layer / Feature Build Function
Conductors L1/L2/L3/N 4×25 compacted Cu, Class 2, ≈7 strands All cores R ≤0.741 Ω/km
Strand compaction Concentric layers rolled compact per core Compact round bundle, clean lugs
XLPE insulation (all cores) Dry-cured PE, ≈1.3 mm Uniform 90°C dielectric
2+2 core laying Four equal cores in two rows Stable compact round bundle
PVC ZC sheath Class C, ≈1.3 mm overall Binds bundle, self-extinguishes
Jacket print Continuous type/size/voltage/length On-site readable spec


3. Electrical Characteristics. All four cores R ≤ 0.741 Ω/km @20 °C. Test 3.5 kV AC / 5 min; ≈ 88 A per core (est., air 30 °C); short-circuit ≈ 2.6 kA / 1 s (est.); 50/60 Hz; unscreened; low-loss XLPE; high stable insulation resistance.

Insulation & Sheath Data

Property

Value

Insulation material

XLPE (cross-linked polyethylene)

Outer sheath material

PVC (ST₂)

Long-term service temp.

90 °C (continuous)

Max. conductor temp. (normal)

90 °C

Short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Test voltage AC (5 min)

3.5 kV

Dielectric strength

≥ 20 kV/mm

Volume resistivity @20 °C

≥ 1×10¹⁴ Ω·cm

Shield

None as standard (can be added)

Electrical Parameters

Parameter

Value

Note

Rated voltage U₀/U

0.6 / 1 kV

GB/T 12706.1 / IEC 60502-1

Max. system voltage

1.2 kV AC

—

Test voltage AC (5 min)

3.5 kV

Routine test

DC resistance @20 °C

≤ 0.727 Ω/km per core

GB/T 3956 Class 2 Cu max (25 mm²)

AC resistance @90 °C (est.)

≈ 0.932 Ω/km per core

—

Current rating in air (30 °C)

3-phase: 115 A​

4×25, touching, in free air

Current rating in tray (30 °C)

3-phase: 130 A​

4×25, spaced 2×OD

Current rating buried in ground (20 °C, thermal resistivity 1.2 K·m/W)

3-phase: 120 A​

direct buried

Current rating in conduit (30 °C)

3-phase: 100 A​

—

Short-circuit current (1 s, Cu, 250 °C)

≈ 2.8 kA (2,800 A) per core

—

Capacitance (core-to-sheath, approx.)

≈ 0.16 µF/km

XLPE

Inductive reactance (approx.)

≈ 0.08 Ω/km

at 50 Hz

Frequency

50/60 Hz AC

—


Reference values: 4×25 at 115 A three-phase, 400 V → max load ≈ 69 kW​ (cos φ = 0.8). Suitable for medium three-phase distribution with full-size neutral, industrial motors, and building feeders.


4. Thermal & Flame. 90 °C continuous, 250 °C short-time; ZC class C self-extinguishing — flame retardancy, not 950°C integrity; survives repeated switching and small-power cycles 0~90°C; indoor preferred, UV jacket optional.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

90 °C (continuous)

Max. short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Min. installation ambient temp.

0 °C (below 0 °C requires preheating)

Service ambient range

−20 °C to +90 °C

Flexing temp. range

0 °C to +90 °C

Fire Performance (ZC-YJV — Flame Retardant C)

Property

Value / Requirement

Flame retardant

GB/T 18380.12 / IEC 60332-1-2​ (single cable, self-extinguishing)

Flame retardant class

Class C​ (ZC) per GB/T 19666

Halogen content

Contains halogen (PVC sheath)

Smoke density

Not low-smoke (PVC)

Corrosivity

Corrosive (PVC)

Toxicity

Toxic fumes when burned (PVC)

EMI shielding

None (no metallic screen/armour)


5. Installation Practice & Handling. 25 mm² lugs on all four cores, small glands to ≈16 mm OD, small hydraulic crimp/torque per table; bend ≥ 15×OD ≈ 240 mm; apply conduit/trunking derating; keep the bundle tidy; verify four-core continuity, phase sequence, neutral and insulation after pulling.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 15 × OD → ≈ 308 mm at Ø20.5 mm

four-core unarmoured

Max. pulling tension

375 N per core (25 mm² × 15 N/mm²)

Cu conductor limit

Direct burial

Suitable (with sand bedding)

—

Surface mounting

Cable tray, ladder, cleats

—

Conduit ID

≥ 40 mm

—

Fixing

cable ties, cleats

—

Impact resistance

Moderate

—

Water resistance

Good (PVC sheath)

—

UV resistance

Fair (PVC degrades outdoors, use UV-resistant PVC or conduit)

—

Flex life

Good (Class 2 stranded)

fixed installation

Termination note

Standard compression lugs or mechanical connectors

—


6. Typical Service Applications. 380/400 V three-phase socket groups, small motors and compressors, mixed power loads, panel feeders and occupied-space four-wire distribution branches.

ZR-YJV 4×25mm² Flame Retardant Copper Power Cable, 0.6/1kV XLPE Insulated PVC Sheath


7. Testing & QA Regime (16 items). Routine: DC resistance on all four 25 cores, 3.5 kV withstand, insulation resistance, four-core continuity, insulation thickness, sheath thickness, dimensional check, strand construction, eccentricity, core color identification, print legibility, mass, jacket finish, packing inspection. Type: ZC flame test, short-circuit rating, sheath mechanical.


Cable Parameters


ZC-YJV 4×25 mm² — LV Flame-Retardant Four-Core Power Cable — Full Parameter Sheet 
4×25 Cu (3 phases L1/L2/L3 + neutral N) · XLPE insulation / PVC sheath · ZC · 0.6/1 kV · ≈16 mm · four equal cores · three-phase socket, small power & mixed distribution loop
Parameter Value Unit Remarks / Standard
01 · Identification
Cable type ZC-YJV — Cu/XLPE/PVC, flame-retardant class C — ZC-YJV denotes a copper conductor with cross-linked polyethylene insulation and a PVC outer sheath; ZC marks a class C flame-retardant PVC compound that self-extinguishes after the ignition source is removed.
Rated voltage (U0/U) 0.6/1 kV 0.6 kV phase-to-earth (U0) and 1 kV phase-to-phase (U) rating defines a general low-voltage cable suited to 380/400 V three-phase socket, small-power and mixed distribution circuits.
Maximum operating voltage (Um) 1.2 kV The 1.2 kV maximum system voltage is the continuous upper phase-to-earth limit the XLPE insulation may withstand in normal service.
Core configuration 4×25 equal cores (L1/L2/L3 + N) — Four equal 25 mm² compacted copper cores laid in a 2+2 bundle: three phases plus a neutral of the same size for balanced and unbalanced small-power loads alike.
Conductor material Compacted stranded annealed copper — Soft annealed copper strands are layer-compacted into round 25 mm² bundles on all four cores for consistent lug entry.
Insulation XLPE cross-linked polyethylene — Chemically cross-linked polyethylene bonds into a heat-resistant dielectric retaining properties at the 90 °C operating temperature.
Sheath PVC, flame-retardant class C (ZC) — An overall PVC jacket binds the four-core bundle and carries the class C flame-retardant formulation; deep slate blue finish.
Flame retardancy ZC class C (self-extinguishing, not fire-rated) — On removal of a flame the cable stops propagating fire; this is flame retardancy, not 950 °C/180 min circuit-integrity fire resistance.
Suitable for Three-phase socket, small power, mixed four-wire — Designed for fixed three-phase socket groups, small power feeders and mixed lighting-plus-power loops where a full-size neutral is preferred.
Application 380V small-power panel & mixed branch — Typically runs from a distribution board to three-phase socket groups, small motors/compressors and mixed load branches.
Application note Not for 950°C circuit-integrity fire duty — Do not substitute this ZC cable for a mineral-insulated or fire-resistant circuit; it cannot maintain live integrity under sustained fire.
02 · Conductors
Core count / area 4 × 25 (L1/L2/L3/N) mm² Four equal 25 mm² conductors; three phases carry load current and the equal-size neutral carries unbalance and harmonic return.
Conductor type Compacted stranded Cu, Class 2 — Class 2 stranded compacted construction gives fixed-wiring conductors that round into a stable four-core bundle for lug termination.
DC resistance (all cores) @ 20°C ≤ 0.741 Ω/km Maximum permitted DC resistance of a 25 mm² copper conductor at 20 °C, applied identically to L1, L2, L3 and N.
Stranding Layer-compacted concentric bundle — Concentric strands are compacted radially per core to reduce gaps, tighten the bundle and present a clean round lug entry on each of the four cores.
Strands (nom., est.) ≈ 7 strands per core — Approximate compacted strand count; exact count follows the conductor standard for 25 mm².
Surface Bare copper; tinned optional — Bare copper suits most indoor use; optional tinned plating improves corrosion resistance in damp or chemically mild sites.
Core identification L1/L2/L3 phase colors + N neutral color — All four cores are color-coded so phase sequence and the equal-size neutral match at the panel terminal block.
Neutral sizing logic Equal-size neutral (4×25) — A full-size neutral suits unbalanced small-power, socket and rectifier/LED loads; no copper saving on the neutral versus a 3+1 reduced-neutral build.
Compaction benefit Compact round bundle, tidy OD, clean crimp — Radial compaction reduces overall diameter versus loose stranding and gives a flat, even lug crimp on every core.
03 · Insulation
Insulation material XLPE (cross-linked polyethylene) — Cross-linked PE delivers a higher continuous temperature rating and lower dielectric loss than PVC insulation for the same size.
Insulation thickness (nom.) ≈ 1.3 mm Uniform nominal radial insulation wall on all four 25 mm² cores; gauged to withstand the 3.5 kV routine test.
Working conductor temp. 90 °C Maximum continuous conductor temperature under rated current without shortening insulation life.
Short-circuit temp. 250 °C Peak conductor temperature the insulation may survive for a short fault duration (seconds) before damage occurs.
Insulation resistance High and stable MΩ·km XLPE keeps a high, stable insulation resistance over life, supporting reliable earth-fault detection on four-wire feeders.
Color L1/L2/L3/N color on request — Insulation colors are matched to local 3-phase convention or supplied natural with printed marking.
Cure type Chemical / dry-cured XLPE — A controlled cross-linking cure locks the polymer network so the insulation stays elastic rather than melting under heat.
04 · Sheath & Flame Retardancy
Sheath material PVC, flame-retardant ZC — The class C PVC outer jacket blends a flame-suppressing formulation while keeping a smooth, printable surface.
Sheath thickness (nom.) ≈ 1.3 mm Nominal overall jacket wall sized to shield the four-core bundle from abrasion and mechanical handling.
Finished outer diameter ≈ 16 mm Compact four-core finished diameter used to size glands, trunking and small conduit on distribution runs.
Flame behavior Self-extinguishing, class C — After the test flame is removed the sample extinguishes without propagating; it is not 950°C fire-rated.
Sheath color Deep slate blue (black/gray on request) — Standard deep slate blue; black or dark gray jackets are supplied for industrial aesthetics on request.
Surface finish Smooth, continuous print — A smooth jacket carries a continuous printed line of type, size, voltage, ZC class and meter length along its length.
05 · Electrical
Rated voltage (U0/U) 0.6/1 kV Low-voltage rating matching 380/400 V small-power and mixed distribution systems.
Max voltage (Um) 1.2 kV Continuous upper system voltage for phase-to-earth insulation stress.
Nominal current (per core, est.) ≈ 88 A Approximate ampacity of a 25 mm² core in free air at 30 °C; reduce for conduit fill and high ambient.
Test voltage (AC) 3.5 kV / 5 min — Routine dielectric withstand applied between each conductor and sheath for five minutes without breakdown.
Insulation resistance High, XLPE MΩ·km Measured after conditioning; confirms no void, crack or contamination in the cured insulation.
Short-circuit current (25 core, 1s, est.) ≈ 2.6 kA Approximate 1-second copper short-time withstand on a 25 mm² core; branch fault coordination.
Frequency 50 / 60 Hz Compatible with both 50 Hz and 60 Hz three-phase power systems.
Dielectric XLPE, low loss — Low dielectric loss keeps heating down under continuous small-power distribution duty.
06 · Thermal & Environment
Normal conductor temp. 90 °C Sustained operating temperature the XLPE insulation is rated for under full load.
Installed ambient 0 ~ +40 °C Recommended continuous ambient around the cable; crowded trunking and ducts require ampacity derating.
Min install temp. 0 °C Avoid cold bending below 0 °C where the PVC jacket and insulation may stiffen and crack.
Burning Self-extinguishing, ZC class C — Class C vertical flame test behavior: flame stops once the external burner is removed.
Outdoor / UV Indoor preferred; UV-grade jacket optional — Standard PVC degrades under prolonged direct sun; specify UV-stabilized jacket for exposed outdoor runs.
Oil / chemicals Resistant to common oils; check aggressive media — Withstands typical site oils; verify against specific solvents, cleaning agents or acid fumes before use.
Temperature cycle Withstands repeated 0~90°C duty — The insulation and jacket survive repeated switching and small-power load cycles without cracking.
07 · Mechanical & Construction
Min bending radius (fixed) ≥ 15 × OD ≈ 240 mm Fixed-installation minimum bend radius for the four-core cable; suitable for panel and trunking routing.
Flexibility Stranded, flexible for panel and conduit — Compact strands remain workable for panel-to-equipment and small-conduit runs.
Shielding / Armor None / unarmored (screen optional) — No braid screen and no armor as standard; add braid screen near control EMI; armor rarely needed at this section.
Cable weight per km (est.) ≈ 1350 kg/km Compact mass per kilometer used for trunking fill and reel sizing.
Circularity Four equal cores, 2+2 bundle — Four equal cores laid 2+2 form a compact round bundle after sheathing.
Tensile / elongation Jacket meets PVC grade — Jacket tensile strength and elongation satisfy the PVC compound grade for routine pulling.
08 · Factory Advantages
Equal-size four-core build 4×25 with full-size neutral for unbalanced loads — A full-size neutral handles socket, small-power and harmonic return without oversizing the phases.
Stable XLPE cure Even cross-linking keeps the 90°C dielectric consistent — Controlled cure prevents soft spots in the insulation under continuous duty.
Dosed ZC compound Flame-retardant PVC self-extinguishes to class C — Self-extinguishing jacket protects distribution boards and occupied wiring spaces.
Length-on-demand Cut to exact panel/branch meter, sealed ends — Custom cut lengths match the measured small-power and mixed distribution route.
Uniform resistance log All four 25 cores R logged to lot — Every core's resistance is recorded for incoming inspection and batch traceability.
Continuous print line Type, size, ZC, voltage and length along jacket — Clear continuous marking lets installers read the four-core spec along distribution runs.
Phase-color option L1/L2/L3/N insulation colors matched to convention — Pre-colored cores reduce wiring errors at panel terminal blocks.
Light reel pack Small reel or coiled length option — Compact mass supports small reels or coiled lengths for site handling.
Certified QA pack Routine + type test record shipped per batch — A complete QA packet supports buyer inspection and distribution commissioning sign-off.
09 · Installation
Laying Socket group, small power, mixed branch — Route in trunking, panels, small conduit or tray; keep the four-core bundle tidy and observe bend radius.
Connectors 25 mm² lugs on all four cores — Crimp matched 25 mm² lugs on L1/L2/L3/N; select small glands sized to ≈16 mm OD.
Bend radius ≥ 15×OD ≈ 240 mm — Maintain the minimum radius around panel entries and trunking elbows to avoid insulation stress.
Parallel runs Derating in bundles and ducts — Adjacent loaded cores share heat; apply derating factors before selecting the distribution breaker.
Site test Continuity + insulation post-laying — After pulling, verify four-core continuity, phase sequence, neutral continuity and insulation resistance.
Termination Strip, small hydraulic crimp, torque — Strip insulation without nicking strands, use matched dies on each lug, and torque per the lug table.
10 · Packing & Applications
Supply length Custom / small drum or coil m Cut to the measured distribution length on a small drum or coil.
Length tolerance Per trade standard for cut lengths — Cut-length tolerance follows the applicable trade standard rather than a fixed meter promise.
Reel type Small wooden reel / coiled length — Light section wound on a small reel or sealed coil; ends sealed against moisture.
Surface marking ZC-YJV, 4×25, 0.6/1kV, ZC, length — Jacket prints type, core section, voltage, flame class and cumulative meter length.
Typical use Three-phase sockets, small motor, mixed branch — Three-phase socket groups, small motors/compressors, mixed power loads and panel feeders.
Storage Dry indoor on reel supports, avoid UV — Store horizontally on timber supports, dry and shaded; keep ends sealed until installation.


Cable Test Parameters


Test Parameters — ZC-YJV 4×25 LV Flame-Retardant Four-Core Cable 
No. Test Item Test Condition / Method Requirement Type
1 DC resistance (all 25 cores) 20 °C, L1/L2/L3/N (25 mm²) ≤0.741 Ω/km Routine
2 Voltage test (AC) 3.5 kV AC, 5 min, core-to-sheath No breakdown Routine
3 Insulation resistance XLPE, 20°C, per core High & stable Routine
4 Continuity 4 cores (3 phases + neutral) Continuous Routine
5 Flame retardancy Class C vertical test Self-extinguish Type
6 Sheath thickness Micrometer, cross-section Nominal ≈1.3 mm Routine
7 Insulation thickness Micrometer, all 25 mm² cores Nominal ≈1.3 mm Routine
8 Dimensional check Caliper, overall OD OD ≈ 16 mm Routine
9 Conductor construction Visual / strand count per core Class 2 compacted Routine
10 Short-circuit rating Calculated / type ≈2.6 kA / 1 s Type
11 Insulation eccentric test Cross-section measure per core Within tolerance Routine
12 Printing legibility Visual Marking readable Routine
13 Mass per unit length Weigh / calculate ≈ 1350 kg/km Routine
14 Core color identification Visual, L1/L2/L3/N Convention colors Routine
15 Jacket finish check Visual surface & print Smooth & legible Routine
16 Packing & reel inspection Visual / reel and sealed ends Sealed ends, sound reel Routine


Cable Cross Section Structure

ZR-YJV 4×25mm² Flame Retardant Copper Power Cable, 0.6/1kV XLPE Insulated PVC Sheath


ZR-YJV 4×25mm² Flame Retardant Copper Power Cable, 0.6/1kV XLPE Insulated PVC Sheath

ZC-YJV 4×25 — Four-Core Cross-Section Construction Diagram 
4×25 equal Cu (L1/L2/L3 + N) / XLPE insulation / PVC ZC sheath · 0.6/1 kV · ZC class C · ≈16 mm · three-phase socket, small power & mixed four-wire branch
No. Layer / Feature Material / Construction Nominal Thickness (mm) Diameter (mm) Detailed Function / Remarks
1 Conductor L1 — phase 1×25 compacted Cu, Class 2, ≈7 strands — ≈ 5.6 Phase 1 core, DC R ≤0.741 Ω/km @20°C; small-power current.
2 Conductor L2 — phase 1×25 compacted Cu, Class 2, ≈7 strands — ≈ 5.6 Phase 2 core, equal size/resistance for balanced three-phase.
3 Conductor L3 — phase 1×25 compacted Cu, Class 2, ≈7 strands — ≈ 5.6 Phase 3 core, equal spec; color-coded for phase sequence.
4 Conductor N — neutral 1×25 compacted Cu, Class 2, ≈7 strands — ≈ 5.6 Equal-size neutral, R ≤0.741 Ω/km; unbalance and harmonic return.
5 Strand compaction Concentric layers rolled compact per core — — Radial compaction closes gaps for a compact round bundle and clean lugs.
6 XLPE insulation (all cores) Dry-cured cross-linked PE, ≈1.3 mm ≈ 1.3 ≈ 8.2 Uniform 90°C dielectric on every core; passes 3.5 kV routine test.
7 2+2 core laying Four equal cores in two rows — — Equal cores laid 2+2 to settle into a compact round finished bundle.
8 PVC ZC sheath Class C jacket, ≈1.3 mm ≈ 1.3 ≈ 16 Binds the four-core bundle; self-extinguishes to class C; slate-blue finish.
9 Jacket print Continuous type/size/voltage/length line — — Marking: ZC-YJV, 4×25, 0.6/1kV, ZC, cumulative length.
Key Dimensions, Electrical & Mechanical Properties (expanded)
Finished cable diameter ≈ 16 mm Compact four-core OD for glands and trunking.
Approx. cable mass (est.) ≈ 1350 kg/km Compact mass; small drum or coil.
Nominal voltage rating 0.6/1 kV Matches 380/400 V distribution systems.
Max voltage (Um) 1.2 kV Phase-to-earth continuous upper limit.
Normal conductor temp. 90 °C Continuous load temperature of XLPE.
Short-circuit temp. 250 °C Short-time fault peak before insulation damage.
DC resistance (all 25 cores) ≤ 0.741 Ω/km Per core @20°C, identical on L1/L2/L3/N.
Neutral sizing Equal-size 25 neutral — Full neutral for unbalanced and harmonic loads.
Nominal core current (est.) ≈ 88 A Per 25 core, free air 30°C; derate in conduit.
Short-circuit rating (1s, est.) ≈ 2.6 kA Branch fault coordination duty.
Flame retardancy ZC class C, self-extinguishing — Not 950°C fire-rated.
Min bending radius (fixed) ≥ 15 × OD ≈ 240 mm Panel and trunking bend radius.
Frequency 50 / 60 Hz Compatible with both power systems.
Insulation resistance High & stable MΩ·km XLPE; supports earth-fault detection.
Dielectric loss Low — XLPE limits heating on distribution duty.
Temperature cycle 0~90°C repeated — Survives switching and load cycling.
Sheath mechanical Jacket meets PVC grade — Tensile/elongation checked at type test.
Pack choice Small drum / coiled length — Light section with sealed cable ends.
Application Socket group, small motor, mixed branch — 380/400 V three-phase sockets, small power and mixed loads.
Schematic — not to exact scale. OD ≈16 mm, weight ≈1350 kg/km, core ampacity ≈88 A free air at 30°C and ≈2.6 kA/1s are (est.) from cross-referenced industry samples. ZC-YJV 4×25 serves 380/400 V three-phase sockets, small motors and mixed four-wire branches; ZC class C self-extinguishes but is not 950°C fire-rated. Estimated values require confirmation against the factory test certificate for the specific batch.


Cable Construction Description


Construction Description — ZC-YJV 4×25 LV flame-retardant four-core cable 
4×25 equal Cu (L1/L2/L3 + N) / XLPE insulation / PVC ZC sheath · 0.6/1 kV · ZC class C · 90°C · ≈16 mm · socket, small power & mixed branch
1. Product Identity & Ratings
ZC-YJV 4×25 rated 0.6/1 kV (Um 1.2), 90°C working, ZC class C; four equal 25 mm² cores (L1/L2/L3 phases plus a full-size neutral) laid 2+2. OD ≈16 mm, ≈1350 kg/km (est.), ≈88 A per core free air at 30°C (est.), small drum or coil. It is a fixed four-wire distribution cable, not a flexible cord and not a 950°C fire-rated circuit.
2. Copper Conductors (4×25 equal)
Four compacted Class 2 Cu cores, all R ≤0.741 Ω/km @20°C; three phases plus an equal-size neutral for unbalance and harmonic return; tinned plating optional; phase-color insulation on request.
3. Strand Compaction & 2+2 Bundle
Concentric strands are rolled compact per core to close gaps and give clean lug entry; four equal cores laid 2+2 form a compact round bundle before sheathing.
4. XLPE Insulation
Dry-cured cross-linked PE ≈1.3 mm on every core; stable 90°C dielectric, low dielectric loss, high insulation resistance; short-circuit peak 250°C; uniform wall across all four cores.
5. Core Identification
L1/L2/L3 phases and the N neutral are identified by insulation color; the equal-size neutral matches the phases visually at the panel terminal block.
6. PVC ZC Sheath
Class C flame-retardant PVC ≈1.3 mm overall, self-extinguishing; deep slate blue standard (black/gray on request); smooth printable surface; binds the four-core bundle and shields from abrasion.
7. Electrical Characteristics
0.6/1 kV, Um 1.2; all cores R ≤0.741 Ω/km; routine 3.5 kV AC/5 min; ≈88 A per core (est., air 30°C); short-circuit ≈2.6 kA/1s (est.); 50/60 Hz; unscreened; low-loss XLPE.
8. Factory Advantages
• Equal-size four-core build.  • Stable XLPE cure.  • Dosed ZC self-extinguish.  • Length-on-demand.  • Uniform resistance log.  • Continuous clear print.  • Phase-color option.  • Light drum pack.  • Certified QA pack.
9. Site Handling & Installation
• Bend 15×OD (≈240 mm).  • 25 mm² lugs on all four cores, glands to ≈16 mm OD, small hydraulic crimp, torque per table.  • Conduit/trunking derating.  • Keep bundle tidy.  • Four-core continuity, sequence, neutral + insulation after pulling.
10. Typical Service Applications
380/400 V three-phase socket groups, small motors and compressors, mixed power loads, panel feeders and occupied-space four-wire distribution branches.
11. Testing & QA
16-item regime: routine DC resistance on all four 25 cores, 3.5 kV withstand, insulation resistance, four-core continuity, insulation thickness, sheath thickness, dimensional check, strand construction, eccentricity, core color identification, print legibility, mass, jacket finish, packing inspection; type ZC flame, short-circuit, sheath mechanical.
12. Packaging, Storage & Notes
Cut to measured distribution length on a small drum or coil with sealed ends; continuous marking; store dry indoor on reel supports, shaded, avoid direct UV. Est. OD/weight/ampacity/short-circuit confirmed against the factory certificate; ZC is flame retardant, not 950°C fire-rated.


8. Factory Advantages.

  • Equal-size four-core build — full-size neutral handles socket, small-power and harmonic return without oversizing phases.
  • Stable XLPE cure — even cross-linking keeps the 90°C dielectric consistent under continuous duty.
  • Dosed ZC compound — self-extinguishing jacket protects distribution boards and occupied spaces.
  • Length-on-demand — cut to exact panel/branch meter with sealed ends.
  • Uniform resistance log — all four 25 cores' R recorded to lot.
  • Continuous print line — type, size, ZC, voltage and length along jacket.
  • Phase-color option — L1/L2/L3/N colors reduce panel wiring errors.
  • Light drum pack — small drum or coiled length for easy site handling.
  • Certified QA pack — routine + type test record shipped per batch.

ZR-YJV 4×25mm² Flame Retardant Copper Power Cable, 0.6/1kV XLPE Insulated PVC Sheath

9. Packaging, Storage & Logistics. Cut to measured distribution length on a small drum or coiled length with sealed ends; continuous marking; store dry indoor on reel supports, shaded, avoid direct UV.

ZR-YJV 4×25mm² Flame Retardant Copper Power Cable, 0.6/1kV XLPE Insulated PVC Sheath


10. Procurement Specification. State "ZC-YJV 4×25", length, class C, phase colors; note the full-size neutral for unbalanced small-power loads and not fire-rated; request the four-core resistance log and 16-item QA record. Est. values confirmed against the factory certificate.


11. Cable Industry FAQ.

  • Q1: How does 4×25 differ from 4×16? One size up: cores 25 vs 16 mm²; slightly larger OD (16 vs 14 mm), heavier (1350 vs 950 kg/km), higher current (88 vs 65 A), lower resistance (0.741 vs 1.15 Ω/km); suited to three-phase socket groups and small-power feeders rather than lighting-only loops.
  • Q2: Why a full-size neutral? Socket, small-power and LED/rectifier loads draw neutral current and harmonics; an equal 25 mm² neutral prevents neutral overheating.
  • Q3: Is ZC fire-resistant? No. Class C self-extinguishes; it does not hold live at 950°C/180min.
  • Q4: DC resistance values? All four 25 mm² cores ≤0.741 Ω/km at 20°C.
  • Q5: Screen or armor? Unscreened standard; add braid screen near control EMI; armor unnecessary at this section.
  • Q6: Current per core? ≈ 88 A (est.) free air 30°C; derate in crowded trunking and ducts.
  • Q7: Bending? ≥ 240 mm (15×OD); fits panel and trunking routing.
  • Q8: Connectors? 25 mm² lugs on L1/L2/L3/N, gland to ≈16 mm OD.
  • Q9: Indoor or outdoor? Indoor preferred; specify UV-stabilized jacket for exposed runs.
  • Q10: Packing? Small drum or sealed coiled length.
  • Q11: What proof ships? Four-core resistance log + 16-test record; est. values confirmed against certificate.