Construction Site Power Cable ZR-YJV 4x35mm²+1x16mm² Flame Retardant Copper XLPE

Construction Site Power Cable ZR-YJV 4x35mm²+1x16mm² Flame Retardant Copper XLPE

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
ZR-YJV 4x35mm²+1x16mm²

Trading Properties

moq
1 Meter
payment method
L/C,T/T
supply capacity
10000 meters per month

Product Summary

Construction Site Power Cable ZR-YJV 4x35mm²+1x16mm² Flame Retardant Copper XLPE Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×35 mm² + 1×16 mm² Four cores of 35 mm² (3 phase + 1 neutral) + one ...

Product Details

Highlight:

xlpe 5 core cable

,

xlpe copper conductor cable

,

flame retardant 5 core cable

Phase/Neutral conductor (×4):
Bare Annealed Copper, Class 2 Stranded, 7×∅2.52 Mm, Conductor Ø ≈ 7.56–8.05 Mm Depending On Compaction
PE conductor (×1):
Bare Annealed Copper, Class 2 Stranded, 7×∅1.70 Mm, Conductor Ø ≈ 5.10–5.45 Mm Depending On Compaction
Phase/Neutral conductor nominal area:
35 Mm²
PE conductor nominal area:
16 Mm²
Number of cores:
5 (4+1)
Phase/Neutral conductor construction:
Class 2, 7×∅2.52 Mm,IEC 60228 / GB/T 3956
PE conductor construction:
Class 2, 7×∅1.70 Mm,IEC 60228 / GB/T 3956
Phase/Neutral conductor diameter (approx.):
7.56–8.05 Mm
PE conductor diameter (approx.):
5.10–5.45 Mm
Insulation (×5):
XLPE
Phase/Neutral insulation thickness:
1.1 Mm (35 Mm² Class)
PE insulation thickness:
0.7 Mm (16 Mm² Class)
Diameter over phase/neutral insulated core:
9.76–10.25 Mm
Diameter over PE insulated core:
6.50–6.85 Mm
Filler / binder:
FR PP Filler + FR Tape
Outer sheath:
Flame-retardant PVC (ZR Grade)
Sheath thickness:
1.6 Mm (GB/T 12706 Multi-core 25–50 Mm² Range)
Overall cable diameter:
21.0 – 25.5 Mm
Design outer diameter:
≈ 22.5 Mm
Approx. weight:
820 – 1000 Kg/km
Design weight:
≈ 900 Kg/km
Cable shape:
Round

Product Description

Construction Site Power Cable ZR-YJV 4x35mm²+1x16mm² Flame Retardant Copper XLPE

Cable Designation & Meaning

Code

Meaning

ZC

Flame retardant Class C 

YJ

Cross-linked polyethylene (XLPE) insulation 

V

Polyvinyl chloride (PVC) sheath 

4×35 mm² + 1×16 mm²

Four cores of 35 mm² (3 phase + 1 neutral) + one earth core of 16 mm² copper conductor


Construction: Three 35 mm² copper conductors (phase L1/L2/L3) + one 35 mm² copper conductor (neutral N) + one 16 mm² copper conductor (earth PE), XLPE insulation, PVC outer sheath. No metallic screen/armour as standard (can be added on request).

Applicable Standards

  • GB/T 12706.1-2020 / IEC 60502-1 — Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1.2 kV) up to 30 kV (Um = 36 kV) — Part 1: Cables for rated voltages of 1 kV (Um = 1.2 kV) and 3 kV (Um = 3.6 kV)
  • GB/T 19666-2019 — Flame retardant and fire resistant wires and cables 
  • GB/T 18380.12 / IEC 60332-1-2 — Flame propagation test for a single vertical insulated wire
  • GB/T 3956-2008 / IEC 60228 — Conductors of insulated cables
  • GB/T 2951-2008 / IEC 60811 — Common test methods for insulating and sheathing materials

Construction Site Power Cable ZR-YJV 4x35mm²+1x16mm² Flame Retardant Copper XLPE


ZR-YJV 4×35+1×16 mm² — Cable Specification & Engineering Data

1. Product Overview & Rating Summary. ZR-YJV 4×35+1×16 sits between the 4×25+1×16 and the heavier 4×50 range in the flame-retardant 4+1-core low-voltage family: four 35 mm² annealed copper phase conductors are cabled around a central 16 mm² copper neutral/PE core, each insulated in XLPE and enclosed in a single ST2 PVC oversheath rated for 0.6/1 kV at 50 Hz. Manufacture and type testing are performed to GB/T 12706.1 / IEC 60502-1, stranding complies with GB/T 3956, and the ZR marking denotes class ZC flame retardance under GB/T 19666. The finished outer diameter is roughly 28.5 mm and the nominal mass is about 1750 kg per kilometre in copper (850 kg/km for the aluminium YJLV equivalent), delivered in 100 m coils or wooden drums with ≥ Ø 1000 mm flanges — approximately 175 kg per 100 m.


2. Layer-by-Layer Construction (Conductor to Jacket).

Layer Construction Wall Diameter
Phase conductor (×4) Annealed Cu, Class 2 compact, 7 × 2.52 mm (1+6) each — ≈ 7.5 mm
Neutral conductor (×1) Annealed Cu, Class 2 compact, 7 × 1.70 mm (1+6) — ≈ 5.4 mm
Phase insulation (×4) XLPE 1.4 mm ≈ 10.3 mm
Neutral insulation (×1) XLPE 1.0 mm ≈ 7.4 mm
Core assembly Central neutral + 4 phase cores cabled around + PP filler + polyester binder — ≈ 25.3 mm (derived)
Outer jacket Flame-retarded PVC, ST2 compound, black 1.6 mm ≈ 28.5 mm (finished)


3. Electrical Characteristics. Each 35 mm² phase conductor is limited to 0.524 Ω/km at 20 °C, climbing to around 0.66 Ω/km at the 90 °C operating point; the 16 mm² neutral/PE is capped at 1.15 Ω/km. Every production length survives the routine 3.5 kV AC power-frequency proof held for five minutes. Finished-cable insulation resistance remains above 36.7 MΩ·km, XLPE volume resistivity exceeds 1×10¹² Ω·cm, and typical values include capacitance ≤ 0.40 μF/km, inductance ≈ 0.28 mH/km and 50 Hz AC impedance ≈ 0.53 Ω/km. On a one-second short circuit each 35 mm² phase withstands about 4.03 kA (the 16 mm² neutral on a 1.84 kA basis), using I = k·A/√t with k = 115 for copper/XLPE. With all four phase cores energised, reference loading is 140 A in free air at 25 °C and 115 A directly buried at 25 °C — engineering estimates to be confirmed against the factory test certificate.

Insulation & Sheath Data

Property

Value

Insulation material

XLPE (cross-linked polyethylene)

Outer sheath material

PVC (ST₂)

Long-term service temp.

90 °C (continuous)

Max. conductor temp. (normal)

90 °C

Short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Test voltage AC (5 min)

3.5 kV

Dielectric strength

≥ 20 kV/mm

Volume resistivity @20 °C

≥ 1×10¹⁴ Ω·cm

Shield

None as standard (can be added)


Electrical Parameters


Parameter

Value

Note

Rated voltage U₀/U

0.6 / 1 kV

Uₘ = 1.2 kV

Test voltage AC (5 min)

3.5 kV

Routine

Type-test voltage

4.0 kV

IEC 60502-1

DC resistance @20 °C (phase/neutral, per core)

≤ 0.524 Ω/km

GB/T 3956 max, 35 mm²

DC resistance @20 °C (PE, per core)

≤ 1.15 Ω/km

GB/T 3956 max, 16 mm²

AC resistance @90 °C (est., phase/neutral)

≈ 0.681 Ω/km

per core

AC resistance @90 °C (est., PE)

≈ 1.50 Ω/km

per core

Current rating in air (30 °C, single circuit, 4-core+1)

≈ 115–130 A

based on 35 mm² phase

Current rating in air (design)

≈ 120 A

apply grouping + ambient correction

Direct buried (20–25 °C, soil 1.0–1.2 K·m/W, 0.7 m)

≈ 135–152 A

common catalogue 140–146 A

Design buried rating

≈ 143 A

soil thermal resistivity correction required

Short-circuit current (1 s, Cu, 250 °C, phase/neutral)

≈ 3.5 kA

35 mm² reference

Short-circuit current (1 s, Cu, 250 °C, PE)

≈ 1.6 kA

16 mm² reference

Frequency

50/60 Hz AC

—


4. Thermal Response & Flame Performance. XLPE sustains a 90 °C continuous conductor temperature and tolerates a 250 °C short-circuit peak for up to five seconds. The cable is rated for service ambients between −20 and +45 °C, must not be uncoiled below 0 °C without pre-conditioning, and uses 25 °C as the reference soil temperature for buried ratings. Flame behaviour meets class ZC of GB/T 19666, proven by both the single-cable vertical test (GB/T 18380.12) and the category-C bunched test (GB/T 18380.35) with char height limited to 2.5 m. The PVC jacket is halogenated and will emit smoke and acid gas in a fire; low-smoke zero-halogen projects must specify WDZ-YJY instead.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

90 °C (continuous)

Max. short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Min. installation ambient temp.

0 °C (below 0 °C requires preheating)

Service ambient range

−20 °C to +90 °C

Flexing temp. range

0 °C to +90 °C

Fire Performance (ZC-YJV — Flame Retardant C)

Property

Value / Requirement

Flame retardant

GB/T 18380.12 / IEC 60332-1-2​ (single cable, self-extinguishing)

Flame retardant class

Class C​ (ZC) per GB/T 19666

Halogen content

Contains halogen (PVC sheath)

Smoke density

Not low-smoke (PVC)

Corrosivity

Corrosive (PVC)

Toxicity

Toxic fumes when burned (PVC)

EMI shielding

None (no metallic screen/armour)


5. Installation Practice & Handling. Bends must not fall below 15 times the actual outer diameter — about 428 mm for this size. Before first energisation, apply the DC site withstand at 4U0 = 2.4 kV for 15 minutes in line with Q/GDW 13244.1-2018. Drums held below 0 °C in storage must be warmed indoors before uncoiling; pulling tension should stay within 5600 N. The 140 A (air) and 115 A (buried) references require derating whenever ambient temperature, cable grouping or soil thermal resistivity deviates from reference conditions. Crimp lugs, glands and heat-shrink termination kits must be matched to the 7.5 mm phase core, 5.4 mm neutral core and ≈ 28.5 mm jacket, and both phase and neutral short-circuit withstand should be coordinated with upstream protective device settings.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 15 × OD → ≈ 338 mm at Ø22.5 mm

five-core unarmoured

Max. pulling tension (phase/neutral)

525 N per core (35 mm² × 15 N/mm²)

Cu conductor limit

Max. pulling tension (earth)

240 N per core (16 mm² × 15 N/mm²)

Cu conductor limit

Direct burial

Suitable (with sand bedding)

—

Surface mounting

Cable tray, ladder, cleats

—

Conduit ID

≥ 40 mm

—

Fixing

cleats, cable ties

—

Impact resistance

Moderate

—

Water resistance

Good (PVC sheath)

—

UV resistance

Fair (PVC degrades outdoors, use UV-resistant PVC or conduit)

—

Flex life

Good (Class 2 stranded)

fixed installation

Termination note

Standard compression lugs or mechanical connectors

—


6. Typical Service Applications. This cross-section serves main and sub-main distribution circuits where the 4×25+1×16 rating is inadequate: main distribution risers in mid-rise commercial buildings, transformer secondary feeders up to about 160 kVA, motor connections in the 15–37 kW range, machine-tool and process-line power leads, workshop and warehouse distribution panels, elevator and escalator supply circuits, and auxiliary power in light-industrial installations. Approved installation methods include steel or PVC conduit, cable trunking, tray and indoor ducting, both indoors and in covered outdoor locations. For direct burial or mechanically exposed routing, the steel-tape armoured ZR-YJV22 variant is recommended.


Construction Site Power Cable ZR-YJV 4x35mm²+1x16mm² Flame Retardant Copper XLPE


7. Testing & Quality Assurance Regime. Routine tests on every length include phase and neutral DC resistance verification (≤ 0.524 / 1.15 Ω/km at 20 °C), the 3.5 kV AC / 5 min withstand, conductor continuity across all five cores and dimensional inspection covering phase insulation ≥ 1.4 mm, neutral insulation ≥ 1.0 mm, sheath ≥ 1.6 mm and overall diameter ≈ 28.5 mm. Sample and type tests comprise the XLPE hot-set trial at 200 ± 3 °C for 15 minutes under 0.2 MPa (load elongation ≤ 175 %, permanent set ≤ 15 %), XLPE tensile ≥ 12.5 MPa with elongation ≥ 200 %, PVC sheath tensile ≥ 10 MPa with elongation ≥ 125 %, PVC thermal stability ≥ 200 minutes at 200 °C, single-cable and category-C bunched flame trials, and bending assessment. Commissioning on site requires insulation-resistance measurement, the DC 2.4 kV / 15 min withstand and positive L1/L2/L3/N/PE identification before switching. A factory test certificate accompanies each drum.


Cable Parameters


ZR-YJV 4×35+1×16 mm² — Full Parameter Sheet
Flame-retardant 4+1-core CU/XLPE/PVC power cable · 0.6/1 kV · GB/T 12706.1 / IEC 60502-1 · finished Ø ≈ 28.5 mm · ≈ 1750 kg/km (Cu) — cross-referenced industry sample data
Section Parameter Value Unit Remarks / Standard
01 · Identification

Cable type ZR-YJV — Flame-retardant, Cu conductor, XLPE insulation, PVC sheath

Rated voltage (U0/U) 0.6/1 kV AC 50 Hz; maximum system voltage Um = 1.2 kV

Rated cross-sectional areas 4 × 35 (phase) + 1 × 16 (neutral) mm² 4+1 five-core configuration, reduced neutral/PE

Conductor material Annealed copper (Cu) — Class 2 compact stranded per GB/T 3956 / IEC 60228

Insulation material Cross-linked polyethylene (XLPE) — 90 °C continuous rating

Sheath material Flame-retardant PVC, ST2 compound — Black; halogen-bearing

Flame-retardant class ZC (ZR) — Per GB/T 19666; ZA/ZB available on request

Standard reference GB/T 12706.1 / IEC 60502-1 — 0.6/1 kV extruded-insulation power cables
02 · Conductor

Phase stranding (×4) 7 × 2.52 mm (7/2.52) — 1+6 compact lay-up; 35 mm² each

Neutral stranding (×1) 7 × 1.70 mm (7/1.70) — 1+6 compact lay-up; 16 mm²

Phase conductor diameter ≈ 7.5 mm Compact strand-lay diameter (est.)

Neutral conductor diameter ≈ 5.4 mm Compact strand-lay diameter (est.)

Phase DC resistance @ 20 °C 0.524 Ω/km Maximum per GB/T 3956 Class 2

Neutral DC resistance @ 20 °C 1.15 Ω/km Maximum per GB/T 3956 Class 2

Phase DC resistance @ 90 °C ≈ 0.66 Ω/km Temperature-corrected (est.)

Copper mass — phase (per core) ≈ 311 kg/km 35 mm² × 8.89 g/cm³

Copper mass — neutral ≈ 142 kg/km 16 mm² × 8.89 g/cm³

Total copper mass ≈ 1387 kg/km 4 × 311 + 142
03 · Insulation

Phase insulation thickness 1.4 mm GB/T 12706.1 specified for 35 mm²

Neutral insulation thickness 1 mm GB/T 12706.1 specified for 16 mm²

Phase core Ø over insulation ≈ 10.3 mm 7.5 + 2 × 1.4

Neutral core Ø over insulation ≈ 7.4 mm 5.4 + 2 × 1.0

Insulation material XLPE — Cross-linked polyethylene

XLPE volume resistivity ≥ 1×10¹² Ω·cm At 20 °C

XLPE tensile strength ≥ 12.5 MPa Type test

XLPE elongation at break ≥ 200 % Type test

XLPE hot-set (200 °C, 15 min, 0.2 MPa) ≤ 175 / ≤ 15 % / % Load elongation / permanent set

Total XLPE mass ≈ 95 kg/km 4 phase + 1 neutral (est.)
04 · Assembly

Core arrangement Neutral at centre + 4 phase cores around — 4+1 five-core lay-up

Filler material Polypropylene (PP) rope — Fills interstices between cores

Binder tape Polyester non-woven tape — Holds assembled cores

Assembled core Ø ≈ 25.3 mm Derived: 28.5 − 2 × 1.6 sheath

Lay-up direction Right-hand (S) — Standard multi-core convention
05 · Sheath

Sheath material Flame-retardant PVC, ST2 — Black, halogen-bearing

Sheath thickness 1.6 mm Per GB/T 12706.1 for ≈ 25.3 mm assembled Ø

Overall finished diameter ≈ 28.5 mm Cross-referenced industry 4+1 sample

Approximate cable mass (Cu) ≈ 1750 kg/km Cross-referenced industry data

Approximate cable mass (Al) ≈ 850 kg/km YJLV equivalent (est.)

PVC tensile strength ≥ 10 MPa Type test

PVC elongation at break ≥ 125 % Type test

PVC thermal stability ≥ 200 min @ 200 °C (HCl evolution)

Mass per 100 m (Cu) ≈ 175 kg/100 m For drum loading estimation
06 · Electrical

Rated voltage U0/U 0.6/1 kV AC 50 Hz

Maximum system voltage Um 1.2 kV —

Phase DC resistance @ 20 °C ≤ 0.524 Ω/km GB/T 3956 Class 2

Neutral DC resistance @ 20 °C ≤ 1.15 Ω/km GB/T 3956 Class 2

AC impedance @ 50 Hz ≈ 0.53 Ω/km √(R² + X²); R-dominant (est.)

Capacitance (typical) ≤ 0.40 μF/km Per phase core (est.)

Inductance (typical) ≈ 0.28 mH/km Multi-core cable (est.)

Insulation resistance @ 90 °C ≥ 36.7 MΩ·km Finished cable, minimum

Routine test voltage 3.5 kV AC / 5 min — Power-frequency withstand, no breakdown

Site commissioning test DC 2.4 kV / 15 min — 4U0 per Q/GDW 13244.1-2018

Air ampacity @ 25 °C ≈ 140 A 4 phase cores loaded, Cu (est.)

Buried ampacity @ 25 °C ≈ 115 A 4 phase cores loaded, Cu (est.)

Short-circuit current (1 s) ≈ 4.03 kA Phase: I = k·A/√t, k=115 for Cu/XLPE
07 · Thermal

Max continuous conductor temp. 90 °C XLPE rated

Max short-circuit temp. (≤ 5 s) 250 °C XLPE limit

Min ambient temp. (service) −20 °C —

Max ambient temp. (service) +45 °C —

Min laying temperature 0 °C Warm drums below 0 °C

Max burial soil temp. 25 °C Reference for ampacity

Thermal coefficient of resistance (Cu) 0.00393 1/°C At 20 °C reference
08 · Fire (ZR)

Flame-retardant class ZC — GB/T 19666 default for ZR marking

Single-cable flame test GB/T 18380.12 — Equivalent IEC 60332-1-2

Bunched flame test GB/T 18380.35 category C — Char height ≤ 2.5 m

Halogen content Halogen-bearing (PVC) — Specify WDZ-YJY for LSZH

Smoke emission Emits smoke under fire — PVC jacket; LSZH alternative available
09 · Installation

Min bending radius (multi-core) ≥ 15 × OD ≈ 428 mm OD = actual finished diameter

Max pulling tension ≤ 5600 N 40 N/mm² of main phase core area (est.)

Recommended drum flange Ø ≥ 1000 mm For this section

Laying methods Conduit, tray, trunking, indoor ducting — Indoor or sheltered outdoor

Direct burial note Use armoured ZR-YJV22 for burial — Unarmoured YJV needs conduit/protection

Termination Crimp lugs + heat-shrink or screw terminals — Size for 7.5 mm phase / 5.4 mm neutral core
10 · Packing

Standard supply length 100 m/coil or drum Custom lengths available

Drum type Wooden drum (≥ Ø 1000 mm flange) — Sealed until installation

Surface marking Type, voltage, supplier, year, metre marks — Per GB/T 6995

Storage conditions Dry, covered, −20 to +45 °C — Away from sunlight, moisture, oils, sharp objects

Transport Coils/drums secured against rolling — Do not drag cable over rough ground


Cable Test Parameters


Test Parameters — ZR-YJV 4×35+1×16 mm²
No. Test Item Test Condition / Method Requirement Type
1 Conductor DC resistance GB/T 3048.4, 20 °C Phase ≤ 0.524 Ω/km; Neutral ≤ 1.15 Ω/km Routine
2 Power-frequency withstand 3.5 kV AC, 5 min No breakdown Routine
3 Insulation resistance GB/T 3048.5, 90 °C ≥ 36.7 MΩ·km Routine
4 Conductor continuity Visual + electrical All 5 cores continuous Routine
5 Dimensional check Micrometer Phase ins. ≥ 1.4 mm; neutral ≥ 1.0 mm; sheath ≥ 1.6 mm; OD ≈ 28.5 mm Routine
6 XLPE hot-set test 200 ± 3 °C, 15 min, 0.2 MPa Load elongation ≤ 175 %; permanent set ≤ 15 % Type
7 XLPE tensile & elongation GB/T 2951.11 Tensile ≥ 12.5 MPa; elongation ≥ 200 % Type
8 PVC sheath tensile & elongation GB/T 2951.11 Tensile ≥ 10 MPa; elongation ≥ 125 % Type
9 PVC thermal stability 200 °C, HCl evolution ≥ 200 min Type
10 Single-cable vertical flame GB/T 18380.12 Self-extinguishing; char ≤ 50 mm above burner Type
11 Bunched cable flame (cat. C) GB/T 18380.35 Char height ≤ 2.5 m Type
12 Bending test ≥ 15 × OD mandrel No crack in insulation or sheath Type
13 Heat deformation (PVC) 80 °C, 4 h, load Deformation ≤ 50 % Type
14 XLPE shrinkage test 130 °C, 1 h Shrinkage ≤ 4 % Type
15 Site DC withstand 4U0 = 2.4 kV DC, 15 min No breakdown (Q/GDW 13244.1-2018) Site
16 Core identification Visual + continuity Correct L1/L2/L3/N/PE identification Site


Cable Cross Section Structure


Construction Site Power Cable ZR-YJV 4x35mm²+1x16mm² Flame Retardant Copper XLPE


ZR-YJV 4×35+1×16 mm² — Cross-Section Construction Diagram (Schematic)
Layered 4+1 conductor build-up from copper strand to PVC jacket · nominal dimensions per GB/T 12706.1 / IEC 60502-1 · finished Ø ≈ 28.5 mm per cross-referenced industry sample
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Phase conductor (Cu) × 4 Annealed copper, Class 2 compact strand — 7 wires of 2.52 mm per core (7/2.52, 1+6 layout), nominal area 35 mm² each — ≈ 7.5 (Ø each phase core) Line-current carrying phase conductors; DC resistance capped at 0.524 Ω/km at 20 °C
2 Neutral conductor (Cu) × 1 Annealed copper, Class 2 compact strand — 7 wires of 1.70 mm (7/1.70, 1+6 layout), nominal area 16 mm² — ≈ 5.4 (Ø neutral core) Return / PE path; DC resistance capped at 1.15 Ω/km at 20 °C
3 Phase insulation (XLPE) × 4 Cross-linked polyethylene dielectric 1.4 ≈ 10.3 (Ø each phase core, incl. insulation) Electrical isolation; 90 °C continuous rating; withstands 3.5 kV for 5 min
4 Neutral insulation (XLPE) × 1 Cross-linked polyethylene dielectric 1 ≈ 7.4 (Ø neutral core, incl. insulation) Electrical isolation for the neutral/PE conductor
5 Core assembly Neutral core at centre + four phase cores cabled around + PP filler + polyester binder tape — ≈ 25.3 (Ø over assembled cores) 4+1 configuration; derived from finished Ø 28.5 − 2×1.6 sheath
6 Outer jacket (PVC) Flame-retardant PVC, ST2 compound, black 1.6 ≈ 28.5 (Ø finished cable) Mechanical and moisture protection; ZC flame retardance per GB/T 19666
Key Dimensions & Properties (expanded)
Finished cable diameter ≈ 28.5 mm Cross-referenced industry 4+1 sample

Approximate cable mass ≈ 1750 kg/km Cu build-up (cross-referenced industry data)

Approximate mass, aluminium build ≈ 850 kg/km YJLV equivalent (est.)

Nominal voltage rating 0.6/1 kV AC 50 Hz; maximum system voltage Um = 1.2 kV

Conductor temperature limits 90 / 250 °C Continuous service / short-circuit (≤ 5 s)

Minimum bend radius (multi-core) ≥ 15 × OD ≈ 428 mm OD = actual finished cable diameter

Flame-retardant classification ZC (ZR) — Per GB/T 19666

Short-circuit current, phase (1 s) ≈ 4.03 kA I = k·A/√t, k=115 for Cu/XLPE

Short-circuit current, neutral (1 s) ≈ 1.84 kA 16 mm² neutral, same k factor

AC impedance @ 50 Hz ≈ 0.53 Ω/km √(R² + X²); R-dominant (est.)

Capacitance (typical) ≤ 0.40 μF/km Per phase core (est.)

Inductance (typical) ≈ 0.28 mH/km Multi-core cable (est.)

Air ampacity @ 25 °C ≈ 140 A 4 phase cores loaded, Cu (est.)

Buried ampacity @ 25 °C ≈ 115 A 4 phase cores loaded, Cu (est.)

Maximum pulling tension ≤ 5600 N 40 N/mm² of main phase core area (est.)







Schematic — not to exact scale. Finished Ø ≈ 28.5 mm and weight ≈ 1750 kg/km from cross-referenced industry samples; conductor/insulation diameters calculated from GB/T 3956 and GB/T 12706.1; ampacity 140/115 A is an engineering estimate for 4+1 cables. Values marked (est.) require confirmation against the factory test certificate.


Construction Description


Construction Description — ZR-YJV 4×35+1×16 mm² 
Layer-by-layer build-up narrative, conductor through outer jacket · per GB/T 12706.1 & IEC 60502-1 · CU / XLPE / PVC · 0.6/1 kV class · finished Ø ≈ 28.5 mm (cross-referenced industry sample)
1. Product Identity & Ratings
ZR-YJV 4×35+1×16 moves up another notch in the 4+1-core flame-retardant series: four 35 mm² annealed copper phase conductors are cabled around a central 16 mm² copper neutral/PE core, each insulated in XLPE and enclosed in a single ST2 PVC jacket for 0.6/1 kV service. It is produced and type-tested to GB/T 12706.1 / IEC 60502-1, stranded to GB/T 3956, and marked ZR for class ZC flame retardance under GB/T 19666. The finished diameter is about 28.5 mm (cross-referenced industry sample) and the nominal mass is roughly 1750 kg per kilometre in copper (850 kg/km for the aluminium YJLV equivalent); standard supply is 100 m coils or wooden drums with ≥ Ø 1000 mm flanges (≈ 175 kg per 100 m).
With all four phase cores energised, the cable supports about 140 A in free air at 25 °C and 115 A directly buried at 25 °C (engineering estimate) — the natural choice where the 4×25+1×16 rating of 115/95 A is too tight. The 4+1 arrangement places the reduced 16 mm² core at the centre and lays the four 35 mm² phase cores around it.
2. Copper Stranded Conductors
Each 35 mm² phase core is formed from seven 2.52 mm annealed wires in the 1+6 compact arrangement (7/2.52) — the Class 2 standard at this cross-section — giving a strand-lay diameter of about 7.5 mm and a DC resistance ceiling of 0.524 Ω/km at 20 °C (about 0.66 Ω/km at the 90 °C operating point). The 16 mm² neutral/PE core uses seven 1.70 mm wires (7/1.70, 1+6) to about 5.4 mm strand-lay Ø, with resistance capped at 1.15 Ω/km. Copper mass alone is about 311 kg/km per phase core and 142 kg/km for the neutral; the seven-wire compact lay-up strikes a balance between flexibility for conduit work and mechanical robustness for repeated tray bending.
3. XLPE Dielectric Insulation
XLPE is extruded at 1.4 mm onto each 35 mm² phase core and 1.0 mm onto the 16 mm² neutral core — producing approximately 10.3 mm per phase core and 7.4 mm for the neutral core over the insulation. The dielectric is rated for 90 °C continuous duty and 250 °C for five seconds, maintains volume resistivity above 1×10¹² Ω·cm, passes the routine 3.5 kV AC five-minute voltage proof, and offers tensile strength ≥ 12.5 MPa with elongation ≥ 200 %. Total XLPE mass is about 95 kg/km.
4. Cabling & PVC Outer Jacket
After insulation, the 16 mm² neutral core is placed at the centre and the four 35 mm² phase cores are cabled around it in a square arrangement with polypropylene filler and a polyester binder tape, forming a bundle of about 25.3 mm diameter (derived from the finished size). A 1.6 mm layer of flame-retarded ST2 PVC is then extruded over the assembly to the ≈ 28.5 mm finish. The jacket provides ZC behaviour through GB/T 18380.12 and GB/T 18380.35, offers tensile strength ≥ 10 MPa and elongation ≥ 125 %; because PVC is halogenated, low-smoke zero-halogen projects should specify WDZ-YJY, and direct-burial projects without added protection should specify steel-tape armoured ZR-YJV22.
5. Site Handling & Operational Notes
• Observe the 15 × OD minimum bending radius (≈ 428 mm).  • Perform the DC 4U0 = 2.4 kV / 15 min commissioning test before first energisation.  • Service ambient spans −20 to +45 °C; warm drums below 0 °C before pulling.  • Derate the 140 A (air) / 115 A (buried) references for ambient temperature, grouping and soil conditions.  • Maximum pulling tension ≤ 5600 N; use appropriate pulling grips.  • Select lugs and terminals matched to the 7.5 mm phase core, 5.4 mm neutral core and ≈ 28.5 mm jacket.  • Short-circuit rating ≈ 4.03 kA for 1 s on the phase (≈ 1.84 kA basis on the neutral) — verify against protective device settings.  • Use drums with ≥ Ø 1000 mm flanges (≈ 175 kg per 100 m).


8. Standards & Conformity. Design and production are governed by GB/T 12706.1 and IEC 60502-1 for 0.6/1 kV extruded-insulation power cables. Conductors satisfy GB/T 3956 / IEC 60228 Class 2 — the 35 mm² phase as seven wires of 2.52 mm with R ≤ 0.524 Ω/km, and the 16 mm² neutral as seven wires of 1.70 mm with R ≤ 1.15 Ω/km. Flame retardance is classified under GB/T 19666 (ZC as the default for the ZR marking) and proven by GB/T 18380.12 and GB/T 18380.35 category C. Installation acceptance follows Q/GDW 13244.1-2018 and GB 50168, while surface marking complies with GB/T 6995. Cables can also be supplied to IEC, BS, DIN, ICEA or JIS requirements on request. Because the ST2 PVC jacket contains halogen, tunnels, metro systems, hospitals and other confined public areas call for WDZ-YJY.


9. Packaging, Storage & Logistics. Standard delivery is 100 m per coil or wooden drum, with bespoke cut lengths available on request. Each drum carries type, voltage, supplier identity, production year and sequential metre marking per GB/T 6995. Storage should be in dry, covered premises at −20 to +45 °C, shielded from direct sunlight, moisture, oils and sharp objects; coils and drums remain sealed until installation and are stored upright on their flanges rather than flat. In cold conditions, condition drums indoors to ≥ 0 °C before pulling. During transit, coils and drums must be secured against rolling and impact, and the cable must never be dragged across abrasive ground or sharp edges.


Construction Site Power Cable ZR-YJV 4x35mm²+1x16mm² Flame Retardant Copper XLPE


10. Procurement Specification. State "ZR-YJV 0.6/1 kV 4×35+1×16" together with the required length or drum arrangement and marking preferences. Specify the flame-retardant class (ZC is standard; ZA or ZB available), jacket colour and any special drum requirements. Always request the factory test certificate to confirm the actual unarmoured diameter (≈ 28.5 mm), weight (≈ 1750 kg/km) and ampacity for the production batch. Where low-smoke zero-halogen or armoured construction is needed, order WDZ-YJY or ZR-YJV22 respectively.


11. Cable Industry FAQ.

  • Q1: How does 4×35+1×16 differ from the smaller 4×25+1×16? The phase area grows from 25 to 35 mm² (conductor from 7×2.14 to 7×2.52 mm) while the neutral stays at 16 mm², raising the rated current from about 115/95 A to 140/115 A, increasing the finished diameter from 25.7 to 28.5 mm, and lifting the one-second phase short-circuit withstand from about 2.88 to 4.03 kA.
  • Q2: Why is the neutral/PE only 16 mm² when the phases are 35 mm²? In a balanced four-wire circuit the neutral carries mainly unbalance and harmonic current, so GB/T 12706.1 permits a reduced core in the 4+1 construction. Where the installation serves substantial single-phase or non-linear, harmonic-generating loads, an equal-section 5-core cable should be chosen.
  • Q3: What do ZA, ZB, ZC and ZD mean? These are flame-retardant classes in GB/T 19666, assessed through the bunched-cable test GB/T 18380.35 at progressively higher fuel loads — ZA is the most demanding, ZD the least. The bare "ZR" marking defaults to ZC; ZA and ZB must be requested at ordering.
  • Q4: When should a 4+1, equal 5-core, or plain 4-core cable be selected? Choose 4+1 for standard four-wire service with a reduced neutral/PE; equal 5-core (4×A+1×A) where neutral current is expected to approach phase current; plain 4-core when no separate PE conductor is required in the cable.
  • Q5: Why do air and buried ratings differ, and how are they adjusted? Published figures assume 25 °C air or 25 °C soil at 1.0 K·m/W thermal resistivity with a single circuit. Manufacturer correction factors must be applied for ambient temperature, grouping, burial depth and soil resistivity — air factors range from about 1.29 at 20 °C down to 0.91 at 45 °C, and soil factors from 1.04 at 20 °C to 0.87 at 40 °C.
  • Q6: Copper or aluminium? Copper (this cable) delivers lower resistance (0.524 versus roughly 0.87 Ω/km at 35 mm²), higher current per mm², better mechanical strength and more dependable terminations; aluminium (YJLV, ≈ 850 kg/km in this size) costs less and weighs less but requires larger cross-sections and anti-oxidation treatment at every joint.
  • Q7: Why can XLPE run at 90 °C while PVC insulation is limited to 70 °C? Cross-linking transforms polyethylene into a three-dimensional thermoset network, which raises the continuous conductor rating to 90 °C and the short-circuit withstand to 250 °C — directly increasing the ampacity available from a given copper area.
  • Q8: How is the conductor cross-section chosen? Selection is governed by (a) full-load current after derating, (b) permissible voltage drop (typically ≤ 5 % for branch circuits), (c) short-circuit withstand on an I²t basis (4.03 kA·s per phase here), and (d) coordination with overcurrent protective devices; the most stringent criterion controls.
  • Q9: Why does finished diameter vary between manufacturers for the same nominal size? Standards set minimum insulation and sheath thicknesses plus electrical performance, but not a precise overall diameter. Stranding compaction, filler design and sheath tolerance differ between plants — published 4×35+1×16 figures cluster around 28.5 mm unarmoured — so the actual measured diameter must always be used when sizing glands, trays and conduits.
  • Q10: Which tests confirm acceptability on delivery and before energisation? At delivery, verify the factory test certificate (resistance 0.524/1.15 Ω/km, 3.5 kV/5 min withstand, dimensions ≈ 28.5 mm), jacket legibility and drum integrity. After installation, complete an insulation-resistance test plus the DC 4U0 = 2.4 kV / 15 min withstand per Q/GDW 13244.1-2018, then confirm L1/L2/L3/N/PE identification before closing the breaker.
  • Q11: What service life can be expected? When installed and operated within the stated temperature and voltage limits, XLPE 0.6/1 kV cables are designed for a minimum service life of 30 years; sustained overload, ultraviolet exposure, water ingress through a damaged sheath, or operation above 90 °C will materially shorten that life.