4x10mm2+1x6mm2 XLPE Copper Cable 0.6kV 1kV Flame Retardant

4x10mm2+1x6mm2 XLPE Copper Cable 0.6kV 1kV Flame Retardant

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
ZR-YJV 4x10mm²+1x6mm²

Trading Properties

moq
100 meters
payment method
L/C,T/T
supply capacity
10000 meters per month

Product Summary

ZR-YJV 4x10mm²+1x6mm² XLPE Copper Cable 0.6/1kV Flame Retardant Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×10 mm² + 1×6 mm² Four cores of 10 mm² (3 phase + 1 neutral) + one earth core of 6 mm² ...

Product Details

Highlight:

ISO 5 core electrical cable

,

Black 5 core electrical cable

,

xlpe insulated pvc sheathed cable

Phase conductor (×4):
Bare Annealed Copper, Class 2 Stranded, 7×∅1.35 Mm, Conductor Ø ≈ 4.05–4.35 Mm Depending On Compaction
Neutral conductor (×1):
Bare Annealed Copper, Class 2 Stranded, 7×∅1.04 Mm, Conductor Ø ≈ 3.12–3.36 Mm Depending On Compaction
Phase conductor nominal area:
10 Mm²
Neutral conductor nominal area:
6 Mm²
Number of cores:
5 (4+1)
Phase conductor construction:
Class 2, 7×∅1.35 Mm,IEC 60228 / GB/T 3956
Neutral conductor construction:
Class 2, 7×∅1.04 Mm,IEC 60228 / GB/T 3956
Phase conductor diameter (approx.):
4.05–4.35 Mm
Neutral conductor diameter (approx.):
3.12–3.36 Mm
Insulation (×5):
XLPE
Phase/Neutral insulation thickness:
0.7 Mm
Diameter over insulated core (all):
5.45 – 5.75 Mm
Filler / binder:
FR PP Filler + FR Tape
Outer sheath:
Flame-retardant PVC (ZR Grade)
Sheath thickness:
1.4 Mm (GB/T 12706 Multi-core ≤10 Mm² Range)
Sheath colour:
Black (standard)
Overall cable diameter:
13.5 – 16.5 Mm
Design outer diameter:
≈ 15.0 Mm
Approx. weight:
280 – 360 Kg/km
Design weight:
≈ 315 Kg/km
Cable shape:
Round

Product Description

ZR-YJV 4x10mm²+1x6mm² XLPE Copper Cable 0.6/1kV Flame Retardant

Cable Designation & Meaning

Code

Meaning

ZC

Flame retardant Class C

YJ

Cross-linked polyethylene (XLPE) insulation 

V

Polyvinyl chloride (PVC) sheath 

4×10 mm² + 1×6 mm²

Four cores of 10 mm² (3 phase + 1 neutral) + one earth core of 6 mm² copper conductor


Construction: Three 10 mm² copper conductors (phase L1/L2/L3) + one 10 mm² copper conductor (neutral N) + one 6 mm² copper conductor (earth PE), XLPE insulation, PVC outer sheath. No metallic screen/armour as standard (can be added on request).

4x10mm2+1x6mm2 XLPE Copper Cable 0.6kV 1kV Flame Retardant

ZC-YJV 4×10+1×6 mm² — LV Flame-Retardant 4+1 Small Distribution Cable — Specification

1. Overview & Ratings. ZC-YJV 4×10+1×6 is a 4+1 LV small distribution cable rated 0.6/1 kV (Um 1.2), 90 °C working, ZC class C PVC sheath: four 10 mm² compacted copper cores (L1/L2/L3 plus PE/spare) and one reduced 6 mm² neutral, dry-cured XLPE, unarmored. OD ≈ 13 mm, ≈ 550 kg/km (est.), ≈ 40 A per large core free air at 30 °C (est.). Scope: compact three-phase branches, control outlets, small feeders and light motor/socket circuits — not 950°C fire duty.


2. Construction Stack (Inner → Outer, expanded).


Layer / Feature Build Function
Cores L1/L2/L3/PE 4×10 compacted Cu, Class 2, ≈7 strands Phases + earth/spare; R ≤1.91
Neutral N 1×6 compacted Cu, reduced, ≈4 strands Balanced return; R ≤3.08
Strand compaction Concentric layers rolled compact per core Compact round bundle, clean lugs
XLPE large-core insulation Dry-cured PE, ≈1.0 mm Uniform 90°C dielectric
XLPE neutral insulation Dry-cured PE, ≈0.8 mm Matched to reduced core
4+1 core laying Four large cores around reduced neutral Compact round bundle
PVC ZC sheath Class C, ≈1.4 mm overall Self-extinguishes, prints clear


3. Electrical Characteristics. Large-core R ≤ 1.91 Ω/km, neutral R ≤ 3.08 Ω/km @20 °C. Test 3.5 kV AC / 5 min; ≈ 40 A per large core (est., air 30 °C); neutral ≈ 30 A (est.); short-circuit ≈ 1.4 kA / 1 s (est.); 50/60 Hz; unscreened; low-loss XLPE; high stable insulation resistance.

Insulation & Sheath Data

Property

Value

Insulation material

XLPE (cross-linked polyethylene)

Outer sheath material

PVC (ST₂)

Long-term service temp.

90 °C (continuous)

Max. conductor temp. (normal)

90 °C

Short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Test voltage AC (5 min)

3.5 kV

Dielectric strength

≥ 20 kV/mm

Volume resistivity @20 °C

≥ 1×10¹⁴ Ω·cm

Shield

None as standard (can be added)

Electrical Parameters

Parameter

Value

Note

Rated voltage U₀/U

0.6 / 1 kV

GB/T 12706.1 / IEC 60502-1

Max. system voltage

1.2 kV AC

—

Test voltage AC (5 min)

3.5 kV

Routine test

DC resistance @20 °C (phase/neutral)

≤ 1.83 Ω/km per core

GB/T 3956 Class 2 Cu max (10 mm²)

DC resistance @20 °C (earth)

≤ 3.08 Ω/km per core

GB/T 3956 Class 2 Cu max (6 mm²)

AC resistance @90 °C (est., phase/neutral)

≈ 2.35 Ω/km per core

—

AC resistance @90 °C (est., earth)

≈ 3.95 Ω/km per core

—

Current rating in air (30 °C)

3-phase: 55 A​

4×10+1×6, touching, in free air

Current rating in tray (30 °C)

3-phase: 62 A​

4×10+1×6, spaced 2×OD

Current rating buried in ground (20 °C, thermal resistivity 1.2 K·m/W)

3-phase: 58 A​

direct buried

Current rating in conduit (30 °C)

3-phase: 48 A​

—

Short-circuit current (1 s, Cu, 250 °C, phase/neutral)

≈ 1.1 kA (1,100 A) per core

—

Short-circuit current (1 s, Cu, 250 °C, earth)

≈ 0.66 kA (660 A) per core

—

Capacitance (core-to-sheath, approx.)

≈ 0.15 µF/km

XLPE

Inductive reactance (approx.)

≈ 0.08 Ω/km

at 50 Hz

Frequency

50/60 Hz AC

—


Reference values: 4×10+1×6 at 55 A three-phase, 400 V → max load ≈ 33 kW​ (cos φ = 0.8). Suitable for small three-phase distribution with reduced earth, control panels, and light machinery.


4. Thermal Response & Flame Performance. XLPE supports a continuous conductor temperature of 90 °C and a short-circuit peak of 250 °C for durations up to five seconds. The cable is rated for service ambients between −20 and +45 °C, should not be laid below 0 °C without pre-warming, and uses 25 °C as the reference soil temperature for buried ratings. Flame behaviour meets class ZC of GB/T 19666, proven by both the single-cable vertical test (GB/T 18380.12) and the category-C bunched test (GB/T 18380.35) with char height limited to 2.5 m. The PVC jacket is halogenated and will produce smoke and acid gas in a fire; projects requiring low-smoke zero-halogen performance must specify WDZ-YJY.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

90 °C (continuous)

Max. short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Min. installation ambient temp.

0 °C (below 0 °C requires preheating)

Service ambient range

−20 °C to +90 °C

Flexing temp. range

0 °C to +90 °C

Fire Performance (ZC-YJV — Flame Retardant C)

Property

Value / Requirement

Flame retardant

GB/T 18380.12 / IEC 60332-1-2​ (single cable, self-extinguishing)

Flame retardant class

Class C​ (ZC) per GB/T 19666

Halogen content

Contains halogen (PVC sheath)

Smoke density

Not low-smoke (PVC)

Corrosivity

Corrosive (PVC)

Toxicity

Toxic fumes when burned (PVC)

EMI shielding

None (no metallic screen/armour)


5. Installation Practice & Handling. Bends must not fall below 15 times the actual outer diameter — approximately 270 mm for this size. Prior to first energisation, apply the DC site withstand at 4U0 = 2.4 kV for 15 minutes in line with Q/GDW 13244.1-2018. Drums held in cold storage below 0 °C must be brought up to temperature before uncoiling; pulling tension should be kept within 1600 N. The 65 A (air) and 55 A (buried) references require derating whenever ambient temperature, cable grouping or soil thermal resistivity deviates from reference conditions. Crimp lugs, glands and heat-shrink termination kits must be selected for the 3.8 mm phase core, 3.0 mm neutral core and ≈ 18 mm jacket, and both phase and neutral short-circuit withstand should be coordinated with upstream protective device settings.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 15 × OD → ≈ 233 mm at Ø15.5 mm

five-core unarmoured

Max. pulling tension (phase/neutral)

150 N per core (10 mm² × 15 N/mm²)

Cu conductor limit

Max. pulling tension (earth)

90 N per core (6 mm² × 15 N/mm²)

Cu conductor limit

Direct burial

Suitable (with sand bedding)

—

Surface mounting

Cable tray, ladder, cleats

—

Conduit ID

≥ 25 mm

—

Fixing

cable ties, small cleats

—

Impact resistance

Moderate

—

Water resistance

Good (PVC sheath)

—

UV resistance

Fair (PVC degrades outdoors, use UV-resistant PVC or conduit)

—

Flex life

Good (Class 2 stranded)

fixed installation

Termination note

Standard compression lugs or mechanical connectors

—


6. Typical Service Applications. This cross-section is the workhorse of building and light-industrial distribution: branch circuits feeding sub-panels, equipment power leads, motor connections in the 5–15 kW range, lighting and socket distribution in commercial and residential buildings, control panel feeds, workshop and laboratory circuits, and auxiliary power connections. Approved installation methods include conduit (steel or PVC), cable trunking, tray and indoor ducting, both indoors and in covered outdoor locations. For direct burial or mechanically exposed routing, the steel-tape armoured ZR-YJV22 variant is recommended.


4x10mm2+1x6mm2 XLPE Copper Cable 0.6kV 1kV Flame Retardant


7. Testing & Quality Assurance Regime. Routine tests on every length include phase and neutral DC resistance verification (≤ 1.83 / 3.08 Ω/km at 20 °C), the 3.5 kV AC / 5 min withstand, conductor continuity across all five cores and dimensional inspection covering phase insulation ≥ 1.0 mm, neutral insulation ≥ 0.7 mm, sheath ≥ 1.4 mm and overall diameter ≈ 18 mm. Sample and type tests comprise the XLPE hot-set trial at 200 ± 3 °C for 15 minutes under 0.2 MPa (load elongation ≤ 175 %, permanent set ≤ 15 %), XLPE tensile ≥ 12.5 MPa with elongation ≥ 200 %, PVC sheath tensile ≥ 10 MPa with elongation ≥ 125 %, PVC thermal stability ≥ 200 minutes at 200 °C, single-cable and category-C bunched flame trials, and bending assessment. Commissioning on site requires insulation-resistance measurement, the DC 2.4 kV / 15 min withstand and positive L1/L2/L3/N/PE identification before switching. A factory test certificate accompanies each drum.


Cable Parameters


ZR-YJV 4×10+1×6 mm² — Full Parameter Sheet 
Flame-retardant 4+1-core CU/XLPE/PVC power cable · 0.6/1 kV · GB/T 12706.1 / IEC 60502-1 · finished Ø ≈ 18 mm · ≈ 625 kg/km (Cu) — Tongdu / Tongdu
Section Parameter Value Unit Remarks / Standard
01 · Identification

Cable type ZR-YJV — Flame-retardant, Cu conductor, XLPE insulation, PVC sheath

Rated voltage (U0/U) 0.6/1 kV AC 50 Hz; maximum system voltage Um = 1.2 kV

Rated cross-sectional areas 4 × 10 (phase) + 1 × 6 (neutral) mm² 4+1 five-core configuration, reduced neutral/PE

Conductor material Annealed copper (Cu) — Class 2 compact stranded per GB/T 3956 / IEC 60228

Insulation material Cross-linked polyethylene (XLPE) — 90 °C continuous rating

Sheath material Flame-retardant PVC, ST2 compound — Black; halogen-bearing

Flame-retardant class ZC (ZR) — Per GB/T 19666; ZA/ZB available on request

Standard reference GB/T 12706.1 / IEC 60502-1 — 0.6/1 kV extruded-insulation power cables
02 · Conductor

Phase stranding (×4) 7 × 1.35 mm (7/1.35) — 1+6 compact lay-up; 10 mm² each

Neutral stranding (×1) 7 × 1.08 mm (7/1.08) — 1+6 compact lay-up; 6 mm²

Phase conductor diameter ≈ 3.8 mm Compact strand-lay diameter (est.)

Neutral conductor diameter ≈ 3.0 mm Compact strand-lay diameter (est.)

Phase DC resistance @ 20 °C 1.83 Ω/km Maximum per GB/T 3956 Class 2

Neutral DC resistance @ 20 °C 3.08 Ω/km Maximum per GB/T 3956 Class 2

Phase DC resistance @ 90 °C ≈ 2.33 Ω/km Temperature-corrected (est.)

Copper mass — phase (per core) ≈ 89 kg/km 10 mm² × 8.89 g/cm³

Copper mass — neutral ≈ 53 kg/km 6 mm² × 8.89 g/cm³

Total copper mass ≈ 409 kg/km 4 × 89 + 53
03 · Insulation

Phase insulation thickness 1 mm GB/T 12706.1 specified for 10 mm²

Neutral insulation thickness 0.7 mm GB/T 12706.1 specified for 6 mm²

Phase core Ø over insulation ≈ 5.8 mm 3.8 + 2 × 1.0

Neutral core Ø over insulation ≈ 4.4 mm 3.0 + 2 × 0.7

Insulation material XLPE — Cross-linked polyethylene

XLPE volume resistivity ≥ 1×10¹² Ω·cm At 20 °C

XLPE tensile strength ≥ 12.5 MPa Type test

XLPE elongation at break ≥ 200 % Type test

XLPE hot-set (200 °C, 15 min, 0.2 MPa) ≤ 175 / ≤ 15 % / % Load elongation / permanent set

Total XLPE mass ≈ 35 kg/km 4 phase + 1 neutral (est.)
04 · Assembly

Core arrangement Neutral at centre + 4 phase cores around — 4+1 five-core lay-up

Filler material Polypropylene (PP) rope — Fills interstices between cores

Binder tape Polyester non-woven tape — Holds assembled cores

Assembled core Ø ≈ 15.2 mm Derived: 18 − 2 × 1.4 sheath

Lay-up direction Right-hand (S) — Standard multi-core convention
05 · Sheath

Sheath material Flame-retardant PVC, ST2 — Black, halogen-bearing

Sheath thickness 1.4 mm Per GB/T 12706.1 for ≈ 15 mm assembled Ø

Overall finished diameter ≈ 18.0 mm Tongdu / Chengtian Tai 4+1 sample

Approximate cable mass (Cu) ≈ 625 kg/km Tongdu 619 / Chengtian 636 cross-ref.

Approximate cable mass (Al) ≈ 340 kg/km YJLV equivalent (est.)

PVC tensile strength ≥ 10 MPa Type test

PVC elongation at break ≥ 125 % Type test

PVC thermal stability ≥ 200 min @ 200 °C (HCl evolution)

Mass per 100 m (Cu) ≈ 62.5 kg/100 m For drum loading estimation
06 · Electrical

Rated voltage U0/U 0.6/1 kV AC 50 Hz

Maximum system voltage Um 1.2 kV —

Phase DC resistance @ 20 °C ≤ 1.83 Ω/km GB/T 3956 Class 2

Neutral DC resistance @ 20 °C ≤ 3.08 Ω/km GB/T 3956 Class 2

AC impedance @ 50 Hz ≈ 1.85 Ω/km √(R² + X²); R-dominant (est.)

Capacitance (typical) ≤ 0.55 μF/km Per phase core (est.)

Inductance (typical) ≈ 0.35 mH/km Multi-core cable (est.)

Insulation resistance @ 90 °C ≥ 36.7 MΩ·km Finished cable, minimum

Routine test voltage 3.5 kV AC / 5 min — Power-frequency withstand, no breakdown

Site commissioning test DC 2.4 kV / 15 min — 4U0 per Q/GDW 13244.1-2018

Air ampacity @ 25 °C ≈ 65 A 4 phase cores loaded, Cu (est.)

Buried ampacity @ 25 °C ≈ 55 A 4 phase cores loaded, Cu (est.)

Short-circuit current (1 s) ≈ 1.15 kA Phase: I = k·A/√t, k=115 for Cu/XLPE
07 · Thermal

Max continuous conductor temp. 90 °C XLPE rated

Max short-circuit temp. (≤ 5 s) 250 °C XLPE limit

Min ambient temp. (service) −20 °C —

Max ambient temp. (service) +45 °C —

Min laying temperature 0 °C Warm drums below 0 °C

Max burial soil temp. 25 °C Reference for ampacity

Thermal coefficient of resistance (Cu) 0.00393 1/°C At 20 °C reference
08 · Fire (ZR)

Flame-retardant class ZC — GB/T 19666 default for ZR marking

Single-cable flame test GB/T 18380.12 — Equivalent IEC 60332-1-2

Bunched flame test GB/T 18380.35 category C — Char height ≤ 2.5 m

Halogen content Halogen-bearing (PVC) — Specify WDZ-YJY for LSZH

Smoke emission Emits smoke under fire — PVC jacket; LSZH alternative available
09 · Installation

Min bending radius (multi-core) ≥ 15 × OD ≈ 270 mm OD = actual finished diameter

Max pulling tension ≤ 1600 N 40 N/mm² of main phase core area (est.)

Recommended drum flange Ø ≥ 800 mm For this section

Laying methods Conduit, tray, trunking, indoor ducting — Indoor or sheltered outdoor

Direct burial note Use armoured ZR-YJV22 for burial — Unarmoured YJV needs conduit/protection

Termination Crimp lugs + heat-shrink or screw terminals — Size for 3.8 mm phase / 3.0 mm neutral core
10 · Packing

Standard supply length 100 m/coil or drum Custom lengths available

Drum type Wooden drum (≥ Ø 800 mm flange) — Sealed until installation

Surface marking Type, voltage, manufacturer, year, metre marks — Per GB/T 6995

Storage conditions Dry, covered, −20 to +45 °C — Away from sunlight, moisture, oils, sharp objects

Transport Coils/drums secured against rolling — Do not drag cable over rough ground


Cable Test Parameters


Test Parameters — ZR-YJV 4×10+1×6 mm²
No. Test Item Test Condition / Method Requirement Type
1 Conductor DC resistance GB/T 3048.4, 20 °C Phase ≤ 1.83 Ω/km; Neutral ≤ 3.08 Ω/km Routine
2 Power-frequency withstand 3.5 kV AC, 5 min No breakdown Routine
3 Insulation resistance GB/T 3048.5, 90 °C ≥ 36.7 MΩ·km Routine
4 Conductor continuity Visual + electrical All 5 cores continuous Routine
5 Dimensional check Micrometer Phase ins. ≥ 1.0 mm; neutral ≥ 0.7 mm; sheath ≥ 1.4 mm; OD ≈ 18 mm Routine
6 XLPE hot-set test 200 ± 3 °C, 15 min, 0.2 MPa Load elongation ≤ 175 %; permanent set ≤ 15 % Type
7 XLPE tensile & elongation GB/T 2951.11 Tensile ≥ 12.5 MPa; elongation ≥ 200 % Type
8 PVC sheath tensile & elongation GB/T 2951.11 Tensile ≥ 10 MPa; elongation ≥ 125 % Type
9 PVC thermal stability 200 °C, HCl evolution ≥ 200 min Type
10 Single-cable vertical flame GB/T 18380.12 Self-extinguishing; char ≤ 50 mm above burner Type
11 Bunched cable flame (cat. C) GB/T 18380.35 Char height ≤ 2.5 m Type
12 Bending test ≥ 15 × OD mandrel No crack in insulation or sheath Type
13 Heat deformation (PVC) 80 °C, 4 h, load Deformation ≤ 50 % Type
14 XLPE shrinkage test 130 °C, 1 h Shrinkage ≤ 4 % Type
15 Site DC withstand 4U0 = 2.4 kV DC, 15 min No breakdown (Q/GDW 13244.1-2018) Site
16 Core identification Visual + continuity Correct L1/L2/L3/N/PE identification Site


Cable Cross Section Structure


4x10mm2+1x6mm2 XLPE Copper Cable 0.6kV 1kV Flame Retardant

ZR-YJV 4×10+1×6 mm² — Cross-Section Construction Diagram (Schematic)
Layered 4+1 conductor build-up from copper strand to PVC jacket · nominal dimensions per GB/T 12706.1 / IEC 60502-1 · finished Ø ≈ 18 mm per / / /cross-referenced sample
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Phase conductor (Cu) × 4 Annealed copper, Class 2 compact strand — 7 wires of 1.35 mm per core (7/1.35, 1+6 layout), nominal area 10 mm² each — ≈ 3.8 (Ø each phase core) Line-current carrying phase conductors; DC resistance capped at 1.83 Ω/km at 20 °C
2 Neutral conductor (Cu) × 1 Annealed copper, Class 2 compact strand — 7 wires of 1.08 mm (7/1.08, 1+6 layout), nominal area 6 mm² — ≈ 3.0 (Ø neutral core) Return / PE path; DC resistance capped at 3.08 Ω/km at 20 °C
3 Phase insulation (XLPE) × 4 Cross-linked polyethylene dielectric 1 ≈ 5.8 (Ø each phase core, incl. insulation) Electrical isolation; 90 °C continuous rating; withstands 3.5 kV for 5 min
4 Neutral insulation (XLPE) × 1 Cross-linked polyethylene dielectric 0.7 ≈ 4.4 (Ø neutral core, incl. insulation) Electrical isolation for the neutral/PE conductor
5 Core assembly Neutral core at centre + four phase cores cabled around + PP filler + polyester binder tape — ≈ 15.2 (Ø over assembled cores) 4+1 configuration; derived from finished Ø 18 − 2×1.4 sheath
6 Outer jacket (PVC) Flame-retardant PVC, ST2 compound, black 1.4 ≈ 18.0 (Ø finished cable) Mechanical and moisture protection; ZC flame retardance per GB/T 19666
Key Dimensions & Properties (expanded)
Finished cable diameter ≈ 18.0 mm /

Approximate cable mass ≈ 625 kg/km Cu build-up

Approximate mass, aluminium build ≈ 340 kg/km YJLV equivalent (est.)

Nominal voltage rating 0.6/1 kV AC 50 Hz; maximum system voltage Um = 1.2 kV

Conductor temperature limits 90 / 250 °C Continuous service / short-circuit (≤ 5 s)

Minimum bend radius (multi-core) ≥ 15 × OD ≈ 270 mm OD = actual finished cable diameter

Flame-retardant classification ZC (ZR) — Per GB/T 19666

Short-circuit current, phase (1 s) ≈ 1.15 kA I = k·A/√t, k=115 for Cu/XLPE

Short-circuit current, neutral (1 s) ≈ 0.69 kA 6 mm² neutral, same k factor

AC impedance @ 50 Hz ≈ 1.85 Ω/km √(R² + X²); R-dominant (est.)

Capacitance (typical) ≤ 0.55 μF/km Per phase core (est.)

Inductance (typical) ≈ 0.35 mH/km Multi-core cable (est.)

Air ampacity @ 25 °C ≈ 65 A 4 phase cores loaded, Cu (est.)

Buried ampacity @ 25 °C ≈ 55 A 4 phase cores loaded, Cu (est.)

Maximum pulling tension ≤ 1600 N 40 N/mm² of main phase core area (est.)

Schematic — not to exact scale. Finished Ø ≈ 18 mm and weight ≈ 625 kg/km from / / /cross-reference; conductor/insulation diameters calculated from GB/T 3956 and GB/T 12706.1; ampacity 65/55 A is an engineering estimate for small-section 4+1 cables. Values marked (est.) require confirmation against the factory test certificate.


Construction Description


Construction Description — ZR-YJV 4×10+1×6 mm² 
Layer-by-layer build-up narrative, conductor through outer jacket · per GB/T 12706.1 & IEC 60502-1 · CU / XLPE / PVC · 0.6/1 kV class · finished Ø ≈ 18 mm
1. Product Identity & Ratings
ZR-YJV 4×10+1×6 is a compact flame-retardant 4+1-core low-voltage cable: four 10 mm² copper phase conductors and a single 6 mm² copper neutral/PE conductor, all XLPE-insulated and enclosed in one ST2 PVC jacket for 0.6/1 kV service. It is produced and type-tested to GB/T 12706.1 / IEC 60502-1, stranded to GB/T 3956, and carries the ZR marking corresponding to class ZC under GB/T 19666. The finished cable measures about 18 mm across (/ Tongdu) and weighs approximately 625 kg per kilometre in copper (340 kg/km for the aluminium YJLV equivalent); standard supply is 100 m coils or small wooden drums with ≥ Ø 800 mm flanges (≈ 62.5 kg per 100 m).
The 4+1 arrangement follows the four-wire-plus-PE format: the reduced 6 mm² core sits at the centre while four 10 mm² phase cores are laid up around it. With all four phase cores energised, the cable supports a reference current of about 65 A in free air at 25 °C and 55 A when directly buried at 25 °C (engineering estimate for small-section 4+1 cables) — suited to branch circuits, sub-panel feeds and equipment connections in buildings and light industry.
2. Copper Stranded Conductors
Each 10 mm² phase core is formed from seven 1.35 mm annealed wires in the 1+6 compact arrangement (7/1.35) — the Class 2 standard for this cross-section — giving a strand-lay diameter of about 3.8 mm and a DC resistance ceiling of 1.83 Ω/km at 20 °C (about 2.33 Ω/km at the 90 °C operating point). The 6 mm² neutral/PE core uses seven 1.08 mm wires (7/1.08, 1+6) to about 3.0 mm strand-lay Ø, with resistance capped at 3.08 Ω/km. Copper mass alone is about 89 kg/km per phase core and 53 kg/km for the neutral; the simple seven-wire construction keeps the small-section core flexible enough for conduit pulling and screw-terminal or crimp termination.
3. XLPE Dielectric Insulation
XLPE is extruded at 1.0 mm onto the phase cores (the GB/T 12706.1 specified value for 10 mm²) and at 0.7 mm onto the 6 mm² neutral core — producing approximately 5.8 mm per phase core and 4.4 mm for the neutral core over the insulation. The dielectric is rated for 90 °C continuous duty and 250 °C for five seconds, maintains volume resistivity above 1×10¹² Ω·cm, passes the routine 3.5 kV AC five-minute voltage proof, and offers tensile strength ≥ 12.5 MPa with elongation ≥ 200 %. Total XLPE mass is about 35 kg/km.
4. Cabling & PVC Outer Jacket
After insulation, the 6 mm² neutral core is placed at the centre and the four 10 mm² phase cores are cabled around it in a square arrangement with polypropylene filler and a polyester binder tape, forming a bundle of about 15.2 mm diameter (derived from the finished size). A 1.4 mm layer of flame-retarded ST2 PVC is then extruded over the assembly to the ≈ 18 mm finish. The jacket provides ZC behaviour through GB/T 18380.12 and GB/T 18380.35, offers tensile strength ≥ 10 MPa and elongation ≥ 125 %; because PVC is halogenated, low-smoke zero-halogen projects should specify WDZ-YJY, and direct-burial projects without added protection should specify steel-tape armoured ZR-YJV22.
5. Site Handling & Operational Notes
• Observe the 15 × OD minimum bending radius (≈ 270 mm).  • Perform the DC 4U0 = 2.4 kV / 15 min commissioning test before first energisation.  • Service ambient spans −20 to +45 °C; warm drums below 0 °C before pulling.  • Derate the 65 A (air) / 55 A (buried) references for ambient temperature, grouping and soil conditions.  • Maximum pulling tension ≤ 1600 N; use appropriate pulling grips.  • Select lugs and terminals matched to the 3.8 mm phase core, 3.0 mm neutral core and ≈ 18 mm jacket.  • Short-circuit rating ≈ 1.15 kA for 1 s on the phase (≈ 0.69 kA basis on the neutral) — verify against protective device settings.  • Use drums with ≥ Ø 800 mm flanges (≈ 62.5 kg per 100 m).



8. Factory Advantages.

  • Balanced 4+1 sizing — four duty cores plus a reduced neutral save copper on balanced small loads.
  • Stable XLPE cure — even cross-linking keeps the 90°C dielectric consistent.
  • Dosed ZC compound — self-extinguishing jacket protects control wiring and panel rooms.
  • Length-on-demand — cut to exact feeder meter with sealed ends.
  • Dual-section resistance log — 10 cores and 6 neutral R recorded to lot.
  • Continuous print line — type, size, ZC, voltage and length readable along runs.
  • Color-coded cores — phase, neutral and PE distinguished at terminals.
  • Lightweight pack — compact drum, easy conduit pulling.
  • Certified QA pack — routine + type test record shipped per batch.

4x10mm2+1x6mm2 XLPE Copper Cable 0.6kV 1kV Flame Retardant


9. Packaging, Storage & Logistics. Standard delivery is 100 m per coil or small wooden drum, with bespoke cut lengths available on request. Each drum carries type, voltage, manufacturer, production year and sequential metre marking per GB/T 6995. Storage should be in dry, covered premises at −20 to +45 °C, shielded from direct sunlight, moisture, oils and sharp objects; coils and drums remain sealed until installation and are stored upright on their flanges rather than flat. In cold conditions, condition drums indoors to ≥ 0 °C before pulling. During transit, coils and drums must be secured against rolling and impact, and the cable must never be dragged across abrasive ground or sharp edges.


4x10mm2+1x6mm2 XLPE Copper Cable 0.6kV 1kV Flame Retardant


10. Procurement Specification. State "ZR-YJV 0.6/1 kV 4×10+1×6" together with the required length or drum arrangement and marking preferences. Specify the flame-retardant class (ZC is standard; ZA or ZB available), jacket colour and any special drum requirements. Always request the factory test certificate to confirm the actual unarmoured diameter (≈ 18 mm), weight (≈ 625 kg/km) and ampacity for the production batch. Where low-smoke zero-halogen or armoured construction is needed, order WDZ-YJY or ZR-YJV22 respectively.


11. Cable Industry FAQ.

  • Q1: What distinguishes YJV, ZR-YJV, YJV22 and WDZ-YJY from one another? YJV denotes the base XLPE-insulated PVC-sheathed cable; ZR-YJV adds flame-retardant properties (class ZC by default); YJV22 introduces a steel-tape armour between the assembly and sheath for direct burial and mechanical robustness; WDZ-YJY substitutes a halogen-free, low-smoke sheath for the PVC, intended for enclosed public spaces.
  • Q2: What is the meaning of ZA, ZB, ZC and ZD? These are flame-retardant classes defined in GB/T 19666, assessed through the bunched-cable test GB/T 18380.35 at progressively higher fuel loads — ZA is the most demanding, ZD the least. The bare "ZR" marking defaults to ZC; ZA and ZB must be explicitly requested at the order stage.
  • Q3: Why is the neutral/PE conductor only 6 mm² when the phases are 10 mm²? In a balanced four-wire circuit the neutral carries primarily unbalance and harmonic current, so GB/T 12706.1 permits a reduced core in the 4+1 construction. If the installation serves substantial single-phase or non-linear, harmonic-generating loads, an equal-section 5-core cable should be considered.
  • Q4: When should a 4+1, 5-core equal, or 4-core cable be selected? Choose 4+1 for standard four-wire service with a reduced neutral/PE; 5-core equal (4×A+1×A) where neutral current is expected to approach phase current; plain 4-core for applications where no separate PE conductor is needed in the cable.
  • Q5: Why do air and buried current ratings differ, and how are they adjusted? Published figures assume 25 °C air or 25 °C soil at 1.0 K·m/W thermal resistivity with a single circuit. Manufacturer correction factors must be applied for ambient temperature, cable grouping, burial depth and soil resistivity — air factors range from about 1.29 at 20 °C down to 0.91 at 45 °C, and soil factors from 1.04 at 20 °C to 0.87 at 40 °C.
  • Q6: Copper or aluminium conductor? Copper (this cable) delivers lower resistance (1.83 versus roughly 3.08 Ω/km at 10 mm²), higher current per mm², superior mechanical strength and more dependable terminations; aluminium (YJLV, ≈ 340 kg/km in this size) costs less and weighs less but demands larger cross-sections and anti-oxidation treatment at every joint.
  • Q7: Why can XLPE operate at 90 °C while PVC insulation is limited to 70 °C? The cross-linking process transforms polyethylene into a three-dimensional thermoset network, which raises the continuous conductor rating to 90 °C and the short-circuit withstand to 250 °C — directly boosting the ampacity available from a given copper area.
  • Q8: How is the conductor cross-section determined? Selection is governed by (a) full-load current after applying derating factors, (b) permissible voltage drop (typically ≤ 5 % for branch circuits), (c) short-circuit withstand on an I²t basis (1.15 kA·s per phase here), and (d) coordination with overcurrent protective devices; the most stringent criterion controls.
  • Q9: Why does finished diameter vary between manufacturers for the same nominal size? Standards mandate minimum insulation and sheath thicknesses together with electrical performance, but not a precise overall diameter. Stranding compaction, filler design and sheath tolerance differ between plants — published 4×10+1×6 figures cluster around 18 mm unarmoured — so the actual measured diameter should always be used when sizing glands, trays and conduits.
  • Q10: Which tests confirm acceptability on delivery and before energisation? At delivery, verify the factory test certificate (resistance 1.83/3.08 Ω/km, 3.5 kV/5 min withstand, dimensions ≈ 18 mm), jacket legibility and drum integrity. After installation, complete an insulation-resistance test plus the DC 4U0 = 2.4 kV / 15 min withstand per Q/GDW 13244.1-2018, then confirm L1/L2/L3/N/PE identification before closing the breaker.
  • Q11: What service life can be expected? When installed and operated within the stated temperature and voltage limits, XLPE 0.6/1 kV cables are designed for a minimum service life of 30 years; sustained overload, ultraviolet exposure, water ingress through a damaged sheath, or operation above 90 °C will materially reduce that lifespan.