logo
Anhui Tongdu International Trade Co., Ltd.
Online Service

Online Service

Contact Person
+86 19056002718
WeChat QR Code
Follow Us

Copper 4 Cores Cable 3x10mm² + 1x6mm2 For Three Phase Power Wiring

Copper 4 Cores Cable 3x10mm² + 1x6mm2 For Three Phase Power Wiring

Basic Properties

country of origin
China
brand name
TD
certificate
CE/ISO/CCC
product model
ZR-YJV 3x10mm²+1x6mm²

Trading Properties

moq
100 meters
payment method
L/C,T/T
supply capacity
10000 meters per month

Product Summary

3+1 Core ZR-YJV Flame Retardant Copper Cable 3x10mm²+1x6mm² for Three Phase Power Wiring Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer ...

Product Details

Highlight:

Copper 4 Cores Cable

,

4 Cores Cable 10mm2

,

Power Wiring fire resistance wire

Phase conductor (×3):
Bare Annealed Copper, Class 2 Stranded, 7×∅1.35 Mm, Conductor Ø ≈ 4.1–4.5 Mm
Neutral conductor (×1):
Bare Annealed Copper, Class 2 Stranded, 7×∅1.04 Mm, Conductor Ø ≈ 3.1–3.4 Mm
Phase conductor nominal area:
10 Mm²
Neutral conductor nominal area:
6 Mm²
Number of cores:
4 (3+1)
Phase conductor construction:
Class 2, 7×∅1.35 Mm,IEC 60228 / GB/T 3956
Neutral conductor construction:
Class 2, 7×∅1.04 Mm,IEC 60228 / GB/T 3956
Phase conductor diameter (approx.):
4.1–4.5 Mm
Neutral conductor diameter (approx.):
3.1–3.4 Mm
Insulation (×4):
XLPE
Insulation thickness:
0.7 Mm(Phase Insulation And Neutral Insulation)
Diameter over phase insulated core:
5.5–5.9 Mm
Diameter over neutral insulated core:
4.5–4.8 Mm
Filler / binder:
FR PP Filler + FR Tape
Outer sheath:
Flame-retardant PVC (ZR Grade)
Sheath thickness:
1.5 Mm (GB/T 12706 Multi-core Small Section)
Overall cable diameter:
13.0 – 16.0 Mm
Design outer diameter:
≈ 14.5 Mm
Approx. weight:
240 – 320 Kg/km
Design weight:
≈ 275 Kg/km
Cable shape:
Round

Product Description

3+1 Core ZR-YJV Flame Retardant Copper Cable 3x10mm²+1x6mm² for Three Phase Power Wiring


Cable Designation & Meaning


Code

Meaning

ZR

Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC).

YJ

XLPE (cross-linked polyethylene) insulation

V

PVC outer sheath — flame-retardant grade, contains halogen (Cl)

0.6/1 kV

Rated voltage U₀/U = 600/1000 V; Uₘ = 1.2 kV

3×10+1×6 mm²

Three phase cores of 10 mm² copper + one smaller neutral core of 6 mm² copper


Copper 4 Cores Cable 3x10mm² + 1x6mm2 For Three Phase Power Wiring

ZC-YJV 3×10+1×6 mm² — LV Flame-Retardant 3+1 Power Cable — Specification

1. Overview & Ratings. ZC-YJV 3×10+1×6 is a 3+1 LV power cable rated 0.6/1 kV (Um 1.2), 90 °C working, ZC class C flame-retardant PVC sheath: three 10 mm² compacted copper phase cores plus one 6 mm² compacted neutral, dry-cured XLPE, unarmored. OD ≈ 12.5 mm, ≈ 480 kg/km (est.), ≈ 50 A per phase free air at 30 °C (est.). Scope: 380/400 V small motor, pump, fan and lighting-group feeds — not 950°C fire duty.


2. Construction Stack (Inner → Outer, expanded).


Layer / Feature Build Function
Conductor L1/L2/L3 3×10 compacted Cu, Class 2, ≈7 strands Phases, R ≤1.91 Ω/km
Conductor N 1×6 compacted Cu, Class 2, ≈7 strands Reduced neutral, R ≤3.08 Ω/km
Strand compaction Concentric layers rolled compact per core Round bundles, clean lug entry
XLPE insulation (phases) Dry-cured PE, ≈1.0 mm 90°C phase dielectric
XLPE insulation (neutral) Dry-cured PE, ≈0.9 mm Neutral dielectric
Core identification L1/L2/L3/N color code Phase sequence + neutral
3+1 core laying 3 phases around neutral Stable round bundle
PVC ZC sheath Class C, ≈1.1 mm overall Binds bundle, self-extinguishes
Jacket print Continuous type/size/voltage/length On-site readable spec


3. Electrical Characteristics. Phase R ≤ 1.91 Ω/km, neutral R ≤ 3.08 Ω/km @20 °C. Test 3.5 kV AC / 5 min; ≈ 50 A per phase (est., air 30 °C); short-circuit ≈ 1.2 kA / 1 s (est.); 50/60 Hz; unscreened; low-loss XLPE; high stable insulation resistance.

Insulation & Sheath Data

Property

Value

Insulation material

XLPE (cross-linked polyethylene)

Outer sheath material

PVC (ST₂)

Long-term service temp.

90 °C (continuous)

Max. conductor temp. (normal)

90 °C

Short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Test voltage AC (5 min)

3.5 kV

Dielectric strength

≥ 20 kV/mm

Volume resistivity @20 °C

≥ 1×10¹⁴ Ω·cm

Shield

None as standard (can be added)

Electrical Parameters

Parameter

Value

Note

Rated voltage U₀/U

0.6 / 1 kV

GB/T 12706.1 / IEC 60502-1

Max. system voltage

1.2 kV AC

—

Test voltage AC (5 min)

3.5 kV

Routine test

DC resistance @20 °C (phase)

≤ 1.83 Ω/km per core

GB/T 3956 Class 2 Cu max (10 mm²)

DC resistance @20 °C (neutral)

≤ 3.08 Ω/km per core

GB/T 3956 Class 2 Cu max (6 mm²)

AC resistance @90 °C (est., phase)

≈ 2.35 Ω/km per core

—

AC resistance @90 °C (est., neutral)

≈ 3.95 Ω/km per core

—

Current rating in air (30 °C)

3-phase: 55 A​

3×10+1×6, touching, in free air

Current rating in tray (30 °C)

3-phase: 60 A​

3×10+1×6, spaced 2×OD

Current rating buried in ground (20 °C, thermal resistivity 1.2 K·m/W)

3-phase: 58 A​

direct buried

Current rating in conduit (30 °C)

3-phase: 48 A​

—

Short-circuit current (1 s, Cu, 250 °C, phase)

≈ 1.1 kA (1,100 A) per core

—

Short-circuit current (1 s, Cu, 250 °C, neutral)

≈ 0.66 kA (660 A) per core

—

Capacitance (core-to-sheath, approx.)

≈ 0.13 µF/km

XLPE

Inductive reactance (approx.)

≈ 0.07 Ω/km

at 50 Hz

Frequency

50/60 Hz AC

—


Reference values: 3×10+1×6 at 55 A three-phase, 400 V → max load ≈ 33 kW​ (cos φ = 0.8). Suitable for small three-phase distribution with reduced neutral, balanced loads, and small motors.


4. Thermal & Flame. 90 °C continuous, 250 °C short-time; ZC class C self-extinguishing — flame retardancy, not 950°C integrity; withstands repeated 0~90°C cycles; indoor; UV-grade jacket optional.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

90 °C (continuous)

Max. short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Min. installation ambient temp.

0 °C (below 0 °C requires preheating)

Service ambient range

−20 °C to +90 °C

Flexing temp. range

0 °C to +90 °C

Fire Performance (ZC-YJV — Flame Retardant C)

Property

Value / Requirement

Flame retardant

GB/T 18380.12 / IEC 60332-1-2​ (single cable, self-extinguishing)

Flame retardant class

Class C​ (ZC) per GB/T 19666

Halogen content

Contains halogen (PVC sheath)

Smoke density

Not low-smoke (PVC)

Corrosivity

Corrosive (PVC)

Toxicity

Toxic fumes when burned (PVC)

EMI shielding

None (no metallic screen/armour)


5. Installation Practice & Handling. 10 mm² phase lugs, 6 mm² neutral lug, small glands, crimp/torque per table; bend ≥ 15×OD ≈ 188 mm; derate bundled/conduit runs; keep the 3+1 bundle round; continuity, phase sequence, neutral + insulation after pulling.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 15 × OD → ≈ 195 mm at Ø13.0 mm

four-core unarmoured

Max. pulling tension (phase)

150 N per core (10 mm² × 15 N/mm²)

Cu conductor limit

Max. pulling tension (neutral)

90 N per core (6 mm² × 15 N/mm²)

Cu conductor limit

Direct burial

Suitable (with sand bedding)

—

Surface mounting

Excellent (cable tray, ladder, cleats)

—

Conduit ID

≥ 20 mm

—

Fixing

cable ties, cleats

—

Impact resistance

Moderate

—

Water resistance

Good (PVC sheath)

—

UV resistance

Fair (PVC degrades outdoors, use UV-resistant PVC or conduit)

—

Flex life

Good (Class 2 stranded)

fixed installation

Termination note

Standard compression lugs or mechanical connectors

—


6. Typical Service Applications. 380/400 V small three-phase motor and pump leads, fan and compressor supplies, mixed lighting-and-power group feeds, small machine auxiliary circuits in light industry and commercial plant.



Copper 4 Cores Cable 3x10mm² + 1x6mm2 For Three Phase Power Wiring


7. Testing & QA Regime (16 items). Routine: phase DC resistance (10), neutral DC resistance (6), 3.5 kV withstand, insulation resistance, continuity, sheath/phase/neutral insulation thickness, dimensional check, strand construction, eccentricity, print legibility, mass. Type: ZC flame test, short-circuit rating, sheath mechanical.


Cable Parameters


ZC-YJV 3×10+1×6 mm² — LV Flame-Retardant 3+1 Power Cable — Full Parameter Sheet 
3×10 Cu phase / 1×6 Cu neutral · XLPE / PVC ZC · 0.6/1 kV · ≈12.5 mm · 3-phase + neutral for 380/400V small machine, pump and lighting group feeds
Parameter Value Unit Remarks / Standard
01 · Identification
Cable type ZC-YJV — Cu/XLPE/PVC, flame-retardant class C — ZC-YJV denotes a copper-conductor cable with cross-linked polyethylene insulation and a PVC outer sheath; the leading ZC marks a Chinese flame-retardant class C compound that self-extinguishes after the ignition source is removed.
Rated voltage (U0/U) 0.6/1 kV 0.6 kV phase-to-earth (U0) and 1 kV phase-to-phase (U) rating defines this as a general low-voltage power cable suited to 380/400 V distribution.
Maximum operating voltage (Um) 1.2 kV The 1.2 kV maximum system voltage is the continuous upper phase-to-earth limit the XLPE insulation may withstand in normal service.
Core configuration 3×10 phase + 1×6 neutral (3+1) — Three 10 mm² compacted copper phase cores around one 6 mm² compacted neutral core, laid 3+1 for balanced small three-phase loads with a reduced neutral.
Conductor material Compacted stranded annealed copper — Soft annealed copper strands are layer-compacted into round bundles: 10 mm² on phases, 6 mm² on the neutral, for clean lug entry.
Insulation XLPE cross-linked polyethylene — Chemically cross-linked polyethylene bonds into a heat-resistant dielectric that keeps its properties at the 90 °C operating temperature.
Sheath PVC, flame-retardant class C (ZC) — An overall PVC jacket binds the 3+1 core bundle and carries the class C flame-retardant formulation; deep mauve purple finish.
Flame retardancy ZC class C (self-extinguishing, not fire-rated) — On removal of a flame the cable stops propagating fire; this is flame-retardancy, not 950 °C/180 min circuit-integrity fire resistance.
Suitable for Fixed indoor tray, conduit, trunking, 3-phase+N — Designed for fixed small three-phase-plus-neutral wiring: small motors, pumps, fan and lighting-group feeds.
Application 380V small 3-phase motor / group feed — Typically runs three phases plus a reduced neutral from a sub-board to a small motor, pump or mixed lighting/power group.
Application note Not for 950°C circuit-integrity fire duty — Do not substitute this ZC cable for a mineral-insulated or fire-resistant circuit; it cannot maintain live integrity under sustained fire.
02 · Conductors
Phase cores count / area 3 × 10 mm² Three 10 mm² phase conductors carry the three phases of a small balanced 400 V load.
Neutral core count / area 1 × 6 mm² One 6 mm² reduced neutral returns unbalanced current; sized for typical small motor and resistive group loads.
Conductor type Compacted stranded Cu, Class 2 — Class 2 stranded compacted construction gives fixed-wiring conductors that round into stable bundles for clean lug termination.
DC resistance (10 phase) @ 20°C ≤ 1.91 Ω/km Maximum permitted DC resistance of a 10 mm² phase copper conductor at 20 °C.
DC resistance (6 neutral) @ 20°C ≤ 3.08 Ω/km Maximum permitted DC resistance of a 6 mm² neutral copper conductor at 20 °C; neutral drop rises slightly on long runs.
Stranding Layer-compacted concentric bundle — Concentric layers of strands are compacted radially per core to reduce gaps, tighten the bundle and present a clean round lug entry.
Strands (nom., est.) 10 ≈7 / 6 ≈7 — Approximate strand counts: about 7 compacted strands in a 10 mm² core and about 7 in the 6 mm² core; exact count follows the standard.
Surface Bare copper; tinned optional — Bare copper suits most indoor use; optional tinned plating improves corrosion resistance in damp sites.
Core identification L1/L2/L3 phase + N neutral by color — Phases and neutral are color-coded so phase sequence and neutral match at the equipment terminal.
Nominal area tolerance Within conductor class 2 band — Actual cross-sectional area and strand geometry stay inside the class 2 tolerance band rather than a solid bare count.
03 · Insulation
Insulation material XLPE (cross-linked polyethylene) — Cross-linked PE delivers a higher continuous temperature rating and lower dielectric loss than ordinary PVC insulation for the same size.
Insulation thickness (phase 10, nom.) ≈ 1.0 mm Nominal radial insulation wall on each 10 mm² phase core; gauged to withstand the 3.5 kV routine test.
Insulation thickness (neutral 6, nom.) ≈ 0.9 mm Slightly reduced wall on the 6 mm² neutral core, still gauged for the routine withstand test.
Working conductor temp. 90 °C Maximum continuous conductor temperature under rated current without shortening insulation life.
Short-circuit temp. 250 °C Peak conductor temperature the insulation may survive for a short fault duration (seconds) before damage occurs.
Insulation resistance High and stable MΩ·km XLPE keeps a high, stable insulation resistance over life, supporting reliable earth-fault detection on 3-phase circuits.
Color L1/L2/L3/N color on request — Insulation colors are matched to local 3-phase convention or supplied natural with printed marking.
Cure type Chemical / dry-cured XLPE — A controlled cross-linking cure locks the polymer network so the insulation stays elastic rather than melting under heat.
04 · Sheath & Flame Retardancy
Sheath material PVC, flame-retardant ZC — The class C PVC outer jacket blends a flame-suppressing formulation while keeping a smooth, printable surface.
Sheath thickness (nom.) ≈ 1.1 mm Nominal overall jacket wall sized to shield the four cores from abrasion, dust and occasional moisture.
Finished outer diameter ≈ 12.5 mm Overall 3+1 finished diameter used to size conduit fill, trunking and gland entry.
Flame behavior Self-extinguishing, class C — After the test flame is removed the sample extinguishes without propagating along the cable; it is not 950°C fire-rated.
Sheath color Deep mauve purple (black/gray on request) — Standard deep mauve purple; black or dark gray jackets are supplied for industrial aesthetics on request.
Surface finish Smooth, continuous print — A smooth jacket carries a continuous printed line of type, size, voltage, ZC class and meter length along its length.
05 · Electrical
Rated voltage (U0/U) 0.6/1 kV Low-voltage rating matching 380/400 V distribution systems.
Max voltage (Um) 1.2 kV Continuous upper system voltage for phase-to-earth insulation stress.
Nominal current (per 10 phase, est.) ≈ 50 A Approximate ampacity of a single 10 mm² phase core in free air at 30 °C; reduce for bundling, duct fill and high ambient.
Test voltage (AC) 3.5 kV / 5 min — Routine dielectric withstand applied between each conductor and sheath for five minutes without breakdown.
Insulation resistance High, XLPE MΩ·km Measured after conditioning; confirms no void, crack or contamination in the cured insulation.
Short-circuit current (10 phase, 1s, est.) ≈ 1.2 kA Approximate 1-second copper short-time withstand on the 10 mm² phase core; small equipment fault duty.
Frequency 50 / 60 Hz Compatible with both 50 Hz and 60 Hz three-phase power systems.
Dielectric XLPE, low loss — Low dielectric loss keeps heating down under continuous small motor and group load.
06 · Thermal & Environment
Normal conductor temp. 90 °C Sustained operating temperature the XLPE insulation is rated for under full load.
Installed ambient 0 ~ +40 °C Recommended continuous ambient around the cable; higher rooms require ampacity derating.
Min install temp. 0 °C Avoid cold bending below 0 °C where the PVC jacket and insulation may stiffen and crack.
Burning Self-extinguishing, ZC class C — Class C vertical flame test behavior: flame stops once the external burner is removed.
Outdoor / UV Indoor preferred; UV-grade jacket optional — Standard PVC degrades under prolonged direct sun; specify UV-stabilized jacket for exposed outdoor runs.
Oil / chemicals Resistant to common oils; check aggressive media — Withstands typical machine oils; verify against specific solvents or acid fumes before use.
Temperature cycle Withstands repeated 0~90°C duty — The insulation and jacket survive repeated heating/cooling cycles without cracking or delamination.
07 · Mechanical & Construction
Min bending radius (fixed) ≥ 15 × OD ≈ 188 mm Fixed-installation minimum bend radius for the 3+1 cable; tighter bends strain insulation and jacket.
Flexibility Stranded, easy to pull on site — Compacted strands keep the cable flexible enough to route through conduit and trunking.
Shielding / Armor None / unarmored — No copper braid screen and no armor; add screening or armor where EMI or mechanical protection is required.
Cable weight per km (est.) ≈ 480 kg/km Approximate mass per kilometer used for tray loading and coil sizing.
Circularity 3+1 core bundle, stable OD — Three phase cores plus one neutral lay into a round bundle so the finished OD stays consistent.
Tensile / elongation Jacket meets PVC grade — Sheath tensile strength and elongation satisfy the PVC compound grade for durable handling.
08 · Factory Advantages
Optimized 3+1 sizing 3×10 phases with 1×6 neutral matches typical small load — Reduced neutral avoids unnecessary copper while still carrying unbalanced current.
Stable XLPE cure Even cross-linking keeps the 90°C dielectric consistent lot to lot — Controlled cure removes soft spots in insulation that would age faster under motor load.
Dosed ZC compound Flame-retardant PVC self-extinguishes to class C — Dosed flame inhibitors give a safety margin in equipment and wiring spaces.
Length-on-demand Cut to exact meter, sealed ends, minimal offcut — Custom cut lengths match the measured machine lead and reduce waste.
Batch resistance log Phase R (10) and neutral R (6) logged against lot — Both phase and neutral resistances are recorded against batch ID for traceability.
Continuous print line Type, size, ZC, voltage and length along jacket — Clear continuous marking lets installers read the spec without a certificate on site.
Phase-color option L1/L2/L3/N insulation colors matched to convention — Pre-colored phases and neutral remove wiring guesswork at the equipment terminal.
Drum or coil pack Supplied on coil or drum to match the run — Coil for short machine leads; drum for longer group feeds.
Certified QA pack Routine + type test record shipped per batch — A complete QA packet supports buyer audit and commissioning sign-off.
09 · Installation
Laying Tray, conduit, trunking, 3-phase+N — Route in fixed supports; keep the 3+1 bundle round and bending above 15×OD.
Connectors 10 mm² phase lugs, 6 mm² neutral lug — Crimp matched 10 mm² lugs on phases and a 6 mm² lug on the neutral; select a gland sized to 12.5 mm OD.
Bend radius ≥ 15×OD ≈ 188 mm — Maintain the minimum radius around corners to prevent insulation cold-working.
Parallel runs Derate when bundled in conduit/tray — Adjacent heating cores share heat; apply bundle derating before sizing the motor breaker.
Site test Continuity + insulation post-laying — After pulling, verify three-phase continuity, neutral, phase sequence and insulation resistance.
Termination Strip, crimp lug, torque per table — Strip insulation without nicking strands, crimp each lug fully, and torque per the lug table.
10 · Packing & Applications
Supply length Custom / coil or drum m Cut to the measured run length; coil or drum packing.
Length tolerance Per trade standard for cut lengths — Cut-length tolerance follows the applicable trade standard rather than a fixed meter promise.
Reel type Coil / wooden drum — Coil for short machine leads; drum for longer group feeds.
Surface marking ZC-YJV, 3×10+1×6, 0.6/1kV, ZC, length — Jacket prints type, 3+1 core size, voltage, flame class and cumulative meter length.
Typical use Small 3-phase motor, pump, fan, lighting group — Runs three phases plus neutral to small equipment and mixed groups.
Storage Dry indoor, avoid direct UV — Store on a pallet, dry and shaded, to keep the jacket intact.


Cable Test Parameters


Test Parameters — ZC-YJV 3×10+1×6 LV Flame-Retardant 3+1 Cable 
No. Test Item Test Condition / Method Requirement Type
1 Phase DC resistance 20 °C, each L1/L2/L3 (10 mm²) 10 ≤1.91 Ω/km Routine
2 Neutral DC resistance 20 °C, N (6 mm²) 6 ≤3.08 Ω/km Routine
3 Voltage test (AC) 3.5 kV AC, 5 min, core-to-sheath No breakdown Routine
4 Insulation resistance XLPE, 20°C, per core High & stable Routine
5 Continuity Each core L1/L2/L3/N Continuous Routine
6 Flame retardancy Class C vertical test Self-extinguish Type
7 Sheath thickness Micrometer, cross-section Nominal ≥1.1 mm Routine
8 Phase insulation thickness Micrometer, 10 mm² cores Nominal ≥1.0 mm Routine
9 Neutral insulation thickness Micrometer, 6 mm² core Nominal ≥0.9 mm Routine
10 Dimensional check Caliper, overall OD OD ≈ 12.5 mm Routine
11 Conductor construction Visual / strand count per core Class 2 compacted Routine
12 Short-circuit rating Calculated / type 1.2 kA / 1 s (phase) Type
13 Insulation eccentric test Cross-section measure per core Within tolerance Routine
14 Printing legibility Visual Marking readable Routine
15 Mass per unit length Weigh / calculate ≈ 480 kg/km Routine
16 Sheath mechanical Tensile / elongation check Meets PVC grade Type


Cable Cross Section Structure 


Copper 4 Cores Cable 3x10mm² + 1x6mm2 For Three Phase Power Wiring


ZC-YJV 3×10+1×6 — 3+1 Cross-Section Construction Diagram
3×10 phase Cu + 1×6 neutral Cu / XLPE insulation / PVC ZC sheath · 0.6/1 kV · ZC class C · ≈12.5 mm · small 3-phase motor, pump, fan & lighting-group feeds
No. Layer / Feature Material / Construction Nominal Thickness (mm) Diameter (mm) Detailed Function / Remarks
1 Conductor L1 — phase 1×10 compacted Cu, Class 2, ≈7 strands — ≈ 3.6 Phase 1 core, DC R ≤1.91 Ω/km @20°C; small motor current.
2 Conductor L2 — phase 1×10 compacted Cu, Class 2, ≈7 strands — ≈ 3.6 Phase 2 core, same size/resistance for balanced impedance.
3 Conductor L3 — phase 1×10 compacted Cu, Class 2, ≈7 strands — ≈ 3.6 Phase 3 core, same spec; color-coded for phase sequence.
4 Conductor N — neutral 1×6 compacted Cu, Class 2, ≈7 strands — ≈ 2.8 Reduced neutral, DC R ≤3.08 Ω/km; returns unbalanced current.
5 Strand compaction Concentric layers rolled compact per core — — Radial compaction closes strand gaps for round bundles and clean lug entry.
6 XLPE insulation (phases) Dry-cured cross-linked PE, ≈1.0 mm ≈ 1.0 ≈ 5.6 90°C dielectric on each 10 mm² phase core, low loss, stable R-insulation.
7 XLPE insulation (neutral) Dry-cured cross-linked PE, ≈0.9 mm ≈ 0.9 ≈ 4.6 Matching neutral insulation; N distinguished by color from phases.
8 3+1 laying & PVC ZC sheath 3 phases + 1 neutral, class C jacket ≈ 1.1 ≈ 12.5 Three phases around the neutral; jacket binds bundle and self-extinguishes.
9 Jacket print Continuous type/size/voltage/length line — — Marking: ZC-YJV, 3×10+1×6, 0.6/1kV, ZC, cumulative length.
Key Dimensions, Electrical & Mechanical Properties (expanded)
Finished cable diameter ≈ 12.5 mm 3+1 overall OD for conduit and small gland sizing.
Approx. cable mass (est.) ≈ 480 kg/km Light group-feed cable, easy to pull.
Nominal voltage rating 0.6/1 kV Matches 380/400 V systems.
Max voltage (Um) 1.2 kV Phase-to-earth continuous upper limit.
Normal conductor temp. 90 °C Continuous load temperature of XLPE.
Short-circuit temp. 250 °C Short-time fault peak before insulation damage.
DC resistance (10 phase) ≤ 1.91 Ω/km Per phase core @20°C.
DC resistance (6 neutral) ≤ 3.08 Ω/km Neutral core @20°C.
Nominal phase current (est.) ≈ 50 A Per 10 phase core, free air 30°C; derate bundled.
Short-circuit rating (1s, est.) ≈ 1.2 kA 10 phase, small equipment fault duty.
Flame retardancy ZC class C, self-extinguishing — Not 950°C fire-rated.
Min bending radius (fixed) ≥ 15 × OD ≈ 188 mm Fixed 3+1 install corner radius.
Frequency 50 / 60 Hz Compatible with both power systems.
Insulation resistance High & stable MΩ·km XLPE; supports earth-fault detection.
Dielectric loss Low — XLPE keeps heating down on group load.
Temperature cycle 0~90°C repeated — Survives heating/cooling without cracking.
Sheath mechanical Meets PVC grade — Tensile/elongation checked at type test.
Pack choice Coil or drum — Coil for short machine leads.
Core configuration 3×10 + 1×6 (3+1) — Three phases + reduced neutral.
Application Small motor, pump, fan, lighting group — 380/400 V small 3-phase+N power.
Schematic — not to exact scale. OD ≈12.5 mm, weight ≈480 kg/km, phase ampacity ≈50 A free air at 30°C and ≈1.2 kA/1s are (est.) from cross-referenced industry samples. ZC-YJV 3×10+1×6 serves 380/400 V small motor, pump, fan and lighting-group feeds; ZC class C self-extinguishes but is not 950°C fire-rated. Estimated values require confirmation against the factory test certificate for the specific batch.


Cable Construction Description


Construction Description — ZC-YJV 3×10+1×6 LV flame-retardant 3+1 cable 
3×10 phase Cu + 1×6 neutral Cu / XLPE insulation / PVC ZC sheath · 0.6/1 kV · ZC class C · 90°C · ≈12.5 mm · small 3-phase motor, pump, fan & lighting-group feeds
1. Product Identity & Ratings
ZC-YJV 3×10+1×6 rated 0.6/1 kV (Um 1.2), 90°C working, ZC class C; three 10 mm² phases plus one 6 mm² neutral in 3+1 lay. OD ≈12.5 mm, ≈480 kg/km (est.), ≈50 A per phase free air at 30°C (est.), coil or drum. It is a fixed small 3-phase+N equipment cable, not a flexible cord and not a 950°C fire-rated circuit.
2. Copper Conductors (3×10 phases + 1×6 neutral)
Three 10 mm² compacted Class 2 Cu phase cores (L1/L2/L3), R ≤1.91 Ω/km @20°C, plus one 6 mm² compacted Cu neutral, R ≤3.08 Ω/km @20°C; reduced neutral matches typical small balanced loads; tinned plating optional; phase-color insulation on request.
3. Strand Compaction & 3+1 Bundle
Concentric strands are rolled compact per core to close gaps and give clean lug entry; the three phase cores lay around the neutral in a controlled 3+1 arrangement to hold a round bundle before sheathing.
4. XLPE Insulation
Dry-cured cross-linked PE ≈1.0 mm on phases and ≈0.9 mm on the neutral; stable 90°C dielectric, low dielectric loss, high and stable insulation resistance; short-circuit peak 250°C; phases and neutral distinguished by color.
5. Core Identification
L1/L2/L3 phases and the N neutral are identified by insulation color so phase sequence and neutral match at the equipment terminal; colors can be supplied to local 3-phase convention.
6. PVC ZC Sheath
Flame-retardant PVC ≈1.1 mm overall, self-extinguishing class C; deep mauve purple standard (black/gray on request); smooth printable surface; binds the 3+1 bundle and shields from abrasion, dust and occasional moisture.
7. Electrical Characteristics
0.6/1 kV, Um 1.2; phase R ≤1.91, neutral R ≤3.08 Ω/km; routine 3.5 kV AC/5 min; ≈50 A per phase (est., air 30°C); short-circuit ≈1.2 kA/1s (est.); 50/60 Hz; unscreened; low-loss XLPE.
8. Factory Advantages
• Optimized 3+1 sizing (3×10 phases + 1×6 neutral).  • Stable XLPE cure lot to lot.  • Dosed ZC self-extinguish.  • Length-on-demand.  • Phase + neutral resistance log.  • Continuous clear print.  • Phase-color option.  • Coil or drum pack.  • Certified QA pack.
9. Site Handling & Installation
• Bend 15×OD (≈188 mm).  • 10 mm² phase lugs, 6 mm² neutral lug, small glands, torque per table.  • Derate bundled/conduit runs.  • Keep 3+1 bundle round.  • Continuity, phase sequence, neutral + insulation after pulling.
10. Typical Service Applications
380/400 V small three-phase motor and pump leads, fan and compressor supplies, mixed lighting-and-power group feeds, small machine auxiliary circuits in light industry and commercial plant.
11. Testing & QA
16-item regime: routine phase DC resistance (10), neutral DC resistance (6), 3.5 kV withstand, insulation resistance, continuity, sheath/phase/neutral insulation thickness, dimensional check, strand construction, eccentricity, print legibility, mass; type ZC flame, short-circuit, sheath mechanical.
12. Packaging, Storage & Notes
Cut to measured length on coil or drum; continuous marking; store dry indoor on a pallet, shaded, avoid direct UV. Est. OD/weight/ampacity/short-circuit confirmed against the factory certificate; ZC is flame retardant, not 950°C fire-rated.


8. Factory Advantages.

  • Optimized 3+1 sizing — 3×10 phases with 1×6 neutral matches typical small load.
  • Stable XLPE cure — even cross-linking keeps the 90°C dielectric consistent.
  • Dosed ZC compound — self-extinguishes to class C.
  • Length-on-demand — exact meter, sealed ends, minimal offcut.
  • Phase + neutral resistance log — both recorded against lot number.
  • Continuous print line — type, size, ZC, voltage and length along jacket.
  • Phase-color option — L1/L2/L3/N colors matched to convention.
  • Coil or drum pack — coil for short machine leads.
  • Certified QA pack — routine + type test record per batch.

Copper 4 Cores Cable 3x10mm² + 1x6mm2 For Three Phase Power Wiring


9. Packaging, Storage & Logistics. Cut to measured length on coil or drum; continuous marking; store dry indoor on a pallet, shaded, avoid direct UV.


Copper 4 Cores Cable 3x10mm² + 1x6mm2 For Three Phase Power Wiring


10. Procurement Specification. State "ZC-YJV 3×10+1×6", length, class C, phase colors, pack; note flame retardant not fire-rated; request phase + neutral resistance log and 16-item QA record. Est. values confirmed against the factory certificate.


11. Cable Industry FAQ.

  • Q1: How does 3×10+1×6 differ from 2×10? It is three phases plus a reduced neutral (3+1) vs a twin L+N pair; slightly thicker (12.5 vs 10.0 mm), heavier (480 vs 320 kg/km), rated for 380/400 V three-phase equipment rather than 230 V lighting.
  • Q2: Why is the neutral only 6 mm²? For small balanced motor and resistive loads the neutral carries little unbalanced current, so a reduced neutral saves copper without sacrificing safety.
  • Q3: Is ZC fire-resistant? No. Class C self-extinguishes; it does not hold live at 950°C/180min.
  • Q4: DC resistance values? Phase 10 ≤1.91 Ω/km; neutral 6 ≤3.08 Ω/km at 20°C.
  • Q5: When would you need a full-size neutral? With heavy single-phase non-linear loads or harmonics; then specify 4×10 rather than 3×10+1×6.
  • Q6: Indoor or outdoor? Indoor preferred; UV-grade jacket for exposed runs.
  • Q7: Current per phase? ≈ 50 A (est.) free air 30°C; derate in conduit.
  • Q8: Connectors? 10 mm² phase lugs, 6 mm² neutral lug, small gland to 12.5 mm OD.
  • Q9: Shielded or armored? Neither standard; add on request.
  • Q10: Packing? Coil for short machine leads, drum for longer group feeds.
  • Q11: What proof ships? Phase + neutral resistance log + 16-test record; est. values confirmed against certificate.