"xlpe copper conductor cable"
- 90 Items Found
Flame Retardant 5 Cores Cable ZR-YJV 35mm2 Xlpe Copper Armoured For Main Power Feeds
Flame Retardant ZR-YJV 5 Core 35mm² Copper Cable for Building Main Power Feeds Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 5×35 mm² Five equal cores of 35 mm² copper conductor Construction : Five ...
WDZBN-YJY 5 Core 3x50mm²+2x25mm² Low Smoke Halogen Free Fire Resistant XLPE Cable 0.6/1kV
WDZBN-YJY 5 Core 3x50mm²+2x25mm² Low Smoke Halogen Free Fire Resistant XLPE Cable 0.6/1kV Cable Designation & Meaning Code Meaning 0.6/1 kV Rated voltage: U₀ = 0.6 kV (phase-to-earth), U = 1 kV (phase-to-phase) WD Low-smoke, zero-halogen (LSZH) ZB Flame retardant Category B (IEC 60332-3-23, Class B) ...
0.6/1kV ZC-YJV 5x16mm² Copper XLPE PVC Flame-Retardant Power Cable for Residential Main Distribution
0.6/1kV ZC-YJV 5x16mm² Copper XLPE PVC Flame-Retardant Power Cable for Residential Main Distribution Technical Datasheet — ZC-YJV 0.6/1 kV 5×16 mm² 1. Cable Designation & Meaning Code Meaning ZC Flame retardant, Class C (bundled combustion test per GB/T 18380.3 / GB/T 19666) YJ XLPE (cross...
Copper Conductor 4 Cores Cable ZR-YJV 4x240mm2 Flame Retardant Cable For Industrial
Copper Conductor 4 Cores Cable ZR-YJV 4x240mm2 Flame Retardant Cable For Industrial Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×240 mm² Four cores of 240 mm² copper conductor each Construction ...
Heavy Duty Pv Cable PV Wire 6.0mm2 XLPE Copper Solar Cable
Heavy Duty PV Wire H1Z2Z2-K 6.0mm² TUV 1500V DC XLPE Copper Solar Cable Cable Designation & Meaning Code Meaning H Harmonized cable (H) 1 Rated voltage 1 kV AC (U₀/U = 1/1 kV reference) Z Halogen-free compound (Z = halogen-free) 2 Insulation layer — cross-linked halogen-free compound (XLPO) Z ...
XLPE Aluminum Power Cable YJLV22 3x50mm² 8.7/15kV Armored 3 Core MV
XLPE Aluminum Power Cable YJLV22 3x50mm² 8.7/15kV Armored 3 Core MV Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...
ZR-YJV 3x240mm²+1x120mm² XLPE Copper Cable 0.6/1kV Flame Retardant
ZR-YJV 3x240mm²+1x120mm² XLPE Copper Cable 0.6/1kV Flame Retardant Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 3×240 mm² + 1×120 mm² Three phase cores of 240 mm² + one neutral core of 120 mm² ...
Copper Power Cable 4 Core ZR-YJV 3×150mm2+1×70mm2 For Power System
Flame Retardant Copper Cable ZR-YJV 3×150mm²+1×70mm² for Commercial Building Power System Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 3×150 mm² + 1×70 mm² Three phase cores of 150 mm² + one ...
ZR-YJV 3x300mm²+1x150mm² XLPE Copper Cable 0.6/1kV Flame Retardant
ZR-YJV 3x300mm²+1x150mm² XLPE Copper Cable 0.6/1kV Flame Retardant Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 3×300 mm² + 1×150 mm² Three phase cores of 300 mm² + one neutral core of 150 mm² ...