Copper Power Cable 4 Core ZR-YJV 3×150mm2+1×70mm2 For Power System

Copper Power Cable 4 Core ZR-YJV 3×150mm2+1×70mm2 For Power System

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
3×150mm²+1×70mm²

Trading Properties

moq
1 Meter
payment method
L/C,T/T
supply capacity
10000 meters per month

Product Summary

Flame Retardant Copper Cable ZR-YJV 3×150mm²+1×70mm² for Commercial Building Power System Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 3×150 mm² + 1×70 mm² Three phase cores of 150 mm² + one ...

Product Details

Highlight:

Copper power cable 4 core

,

power cable 4 core 3×150mm2

,

Power System xlpe copper cable

Phase conductor (×3):
Bare Annealed Copper, Class 2 Stranded, 37×∅2.27 Mm, Conductor Ø ≈ 15.9–16.8 Mm Depending On Compaction
Neutral conductor (×1):
Bare Annealed Copper, Class 2 Stranded, 19×∅2.14 Mm, Conductor Ø ≈ 10.7–11.2 Mm Depending On Compaction
Phase conductor nominal area:
150 Mm²
Neutral conductor nominal area:
70 Mm²
Number of cores:
4 (3+1)
Phase conductor construction:
Class 2, 37×∅2.27 Mm,IEC 60228 / GB/T 3956
Neutral conductor construction:
Class 2, 19×∅2.14 Mm,IEC 60228 / GB/T 3956
Phase conductor diameter (approx.):
15.9–16.8 Mm
Neutral conductor diameter (approx.):
10.7–11.2 Mm
Insulation (×4):
XLPE
Phase insulation thickness:
1.4 Mm (150 Mm² Class)
Neutral insulation thickness:
1.1 Mm (70 Mm² Class)
Diameter over phase insulated core:
18.7–19.6 Mm
Diameter over neutral insulated core:
12.9–13.4 Mm
Filler / binder:
FR PP Filler + FR Tape
Outer sheath:
Flame-retardant PVC (ZR Grade)
Sheath thickness:
1.9 Mm (GB/T 12706 Multi-core 120–185 Mm² Range)
Overall cable diameter:
34.5 – 41.0 Mm
Design outer diameter:
≈ 37.0 Mm
Approx. weight:
1850 – 2300 Kg/km
Design weight:
≈ 2050 Kg/km
Cable shape:
Round

Product Description

Flame Retardant Copper Cable ZR-YJV 3×150mm²+1×70mm² for Commercial Building Power System

Cable Designation & Meaning

Code

Meaning

ZC

Flame retardant Class C 

YJ

Cross-linked polyethylene (XLPE) insulation 

V

Polyvinyl chloride (PVC) sheath 

3×150 mm² + 1×70 mm²

Three phase cores of 150 mm² + one neutral core of 70 mm² copper conductor


Construction: Three 150 mm² copper conductors (phase) + one 70 mm² copper conductor (neutral), XLPE insulation, PVC outer sheath. No metallic screen/armour as standard (can be added on request).



Copper Power Cable 4 Core ZR-YJV 3×150mm2+1×70mm2 For Power System

ZC-YJV 3×150+1×70 mm² — LV Flame-Retardant 3+1 Power Cable — Specification

1. Overview & Ratings. ZC-YJV 3×150+1×70 is a heavy 3+1 LV feeder cable rated 0.6/1 kV (Um 1.2), 90 °C working, ZC class C PVC sheath: three 150 mm² compacted copper phase cores plus one 70 mm² neutral, dry-cured XLPE, unarmored (braid screen / steel-tape armor optional). OD ≈ 34 mm, ≈ 5600 kg/km (est.), ≈ 300 A per phase free air at 30 °C (est.). Scope: 380/400 V main motors, workshop distribution feeders and large equipment supplies — not 950°C fire duty.


2. Construction Stack (Inner → Outer, expanded).


Layer / Feature Build Function
Phase conductors L1/L2/L3 3×150 compacted Cu, Class 2, ≈37 strands Phases, R ≤0.124 Ω/km
Neutral conductor N 1×70 compacted Cu, Class 2, ≈19 strands Reduced neutral, R ≤0.268 Ω/km
Strand compaction Concentric layers rolled compact per core Heavy round bundle, clean lugs
XLPE insulation (phases) Dry-cured PE, ≈2.4 mm 90°C phase dielectric
XLPE insulation (neutral) Dry-cured PE, ≈2.2 mm Matched neutral dielectric
3+1 core laying 3 phases around 1 neutral Stable heavy round bundle
PVC ZC sheath Class C, ≈2.2 mm overall Binds bundle, self-extinguishes
Jacket print Continuous type/size/voltage/length On-site readable spec


3. Electrical Characteristics. Phase R ≤ 0.124 Ω/km, neutral R ≤ 0.268 Ω/km @20 °C. Test 3.5 kV AC / 5 min; ≈ 300 A per phase (est., air 30 °C); short-circuit ≈ 15 kA / 1 s (est.); 50/60 Hz; unscreened; low-loss XLPE; high stable insulation resistance.

Insulation & Sheath Data

Property

Value

Insulation material

XLPE (cross-linked polyethylene)

Outer sheath material

PVC (ST₂)

Long-term service temp.

90 °C (continuous)

Max. conductor temp. (normal)

90 °C

Short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Test voltage AC (5 min)

3.5 kV

Dielectric strength

≥ 20 kV/mm

Volume resistivity @20 °C

≥ 1×10¹⁴ Ω·cm

Shield

None as standard (can be added)

Electrical Parameters

Parameter

Value

Note

Rated voltage U₀/U

0.6 / 1 kV

GB/T 12706.1 / IEC 60502-1

Max. system voltage

1.2 kV AC

—

Test voltage AC (5 min)

3.5 kV

Routine test

DC resistance @20 °C (phase)

≤ 0.124 Ω/km per core

GB/T 3956 Class 2 Cu max (150 mm²)

DC resistance @20 °C (neutral)

≤ 0.268 Ω/km per core

GB/T 3956 Class 2 Cu max (70 mm²)

AC resistance @90 °C (est., phase)

≈ 0.159 Ω/km per core

—

AC resistance @90 °C (est., neutral)

≈ 0.343 Ω/km per core

—

Current rating in air (30 °C)

3-phase: 330 A​

3×150+1×70, touching, in free air

Current rating in tray (30 °C)

3-phase: 365 A​

3×150+1×70, spaced 2×OD

Current rating buried in ground (20 °C, thermal resistivity 1.2 K·m/W)

3-phase: 340 A​

direct buried

Current rating in conduit (30 °C)

3-phase: 290 A​

—

Short-circuit current (1 s, Cu, 250 °C, phase)

≈ 16.5 kA (16,500 A) per core

—

Short-circuit current (1 s, Cu, 250 °C, neutral)

≈ 7.7 kA (7,700 A) per core

—

Capacitance (core-to-sheath, approx.)

≈ 0.25 µF/km

XLPE

Inductive reactance (approx.)

≈ 0.09 Ω/km

at 50 Hz

Frequency

50/60 Hz AC

—


Reference values: 3×150+1×70 at 330 A three-phase, 400 V → max load ≈ 198 kW​ (cos φ = 0.8). Suitable for large three-phase distribution with reduced neutral, heavy industrial motors, and main building feeders.


4. Thermal & Flame. 90 °C continuous, 250 °C short-time; ZC class C self-extinguishing — flame retardancy, not 950°C integrity; survives repeated start-switch cycles 0~90°C; indoor preferred, UV jacket optional.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

90 °C (continuous)

Max. short-circuit temp. (≤5 s)

250 °C

Emergency overload temp.

130 °C (≤1 h)

Min. installation ambient temp.

0 °C (below 0 °C requires preheating)

Service ambient range

−20 °C to +90 °C

Flexing temp. range

0 °C to +90 °C

Fire Performance (ZC-YJV — Flame Retardant C)

Property

Value / Requirement

Flame retardant

GB/T 18380.12 / IEC 60332-1-2​ (single cable, self-extinguishing)

Flame retardant class

Class C​ (ZC) per GB/T 19666

Halogen content

Contains halogen (PVC sheath)

Smoke density

Not low-smoke (PVC)

Corrosivity

Corrosive (PVC)

Toxicity

Toxic fumes when burned (PVC)

EMI shielding

None (no metallic screen/armour)


5. Installation Practice & Handling. 150 mm² phase lugs, 70 mm² neutral lug, heavy glands to ≈34 mm OD, hydraulic crimp/torque per table; bend ≥ 15×OD ≈ 510 mm; apply duct/bundle derating; keep the 3+1 bundle round; verify three-phase continuity, sequence, neutral and insulation after pulling.

Mechanical & Installation Parameters

Parameter

Value

Remarks

Minimum bending radius

≥ 15 × OD → ≈ 570 mm at Ø38.0 mm

four-core unarmoured

Max. pulling tension (phase)

2,250 N per core (150 mm² × 15 N/mm²)

Cu conductor limit

Max. pulling tension (neutral)

1,050 N per core (70 mm² × 15 N/mm²)

Cu conductor limit

Direct burial

Suitable (with sand bedding)

—

Surface mounting

Heavy-duty cable tray, ladder, cleats

—

Conduit ID

≥ 75 mm

—

Fixing

heavy-duty cleats, cable ties

—

Impact resistance

Moderate

—

Water resistance

Good (PVC sheath)

—

UV resistance

Fair (PVC degrades outdoors, use UV-resistant PVC or conduit)

—

Flex life

Good (Class 2 stranded)

fixed installation

Termination note

Standard compression lugs or mechanical connectors

—


6. Typical Service Applications. 380/400 V large three-phase motors, compressors, furnaces, workshop distribution feeders, MCC-to-equipment heavy supplies and plant feeder circuits.

Copper Power Cable 4 Core ZR-YJV 3×150mm2+1×70mm2 For Power System


7. Testing & QA Regime (16 items). Routine: phase DC resistance (150), neutral DC resistance (70), 3.5 kV withstand, insulation resistance, 3-phase+neutral continuity, phase/neutral insulation thickness, sheath thickness, dimensional check, strand construction, eccentricity, print legibility, mass, packing inspection. Type: ZC flame test, short-circuit rating, sheath mechanical.


Cable Parameters


ZC-YJV 3×150+1×70 mm² — LV Flame-Retardant 3+1 Power Cable — Full Parameter Sheet 
3×150 phase Cu + 1×70 neutral Cu · XLPE insulation / PVC sheath · ZC · 0.6/1 kV · ≈34 mm · 3+1 lay · 380/400 V main motor, plant feeder & large equipment supply
Parameter Value Unit Remarks / Standard
01 · Identification
Cable type ZC-YJV — Cu/XLPE/PVC, flame-retardant class C — ZC-YJV denotes a copper conductor with cross-linked polyethylene insulation and a PVC outer sheath; ZC marks a class C flame-retardant PVC compound that self-extinguishes after the ignition source is removed.
Rated voltage (U0/U) 0.6/1 kV 0.6 kV phase-to-earth (U0) and 1 kV phase-to-phase (U) rating defines a general low-voltage cable suited to 380/400 V main motor and plant feeder circuits.
Maximum operating voltage (Um) 1.2 kV The 1.2 kV maximum system voltage is the continuous upper phase-to-earth limit the XLPE insulation may withstand in normal service.
Core configuration 3×150 phase + 1×70 neutral (3+1) — Three 150 mm² compacted copper phase cores plus one 70 mm² compacted neutral core, laid in a heavy 3+1 arrangement for large motors and main feeders.
Conductor material Compacted stranded annealed copper — Soft annealed copper strands are layer-compacted into round 150 mm² phase and 70 mm² neutral bundles for heavy lug entry.
Insulation XLPE cross-linked polyethylene — Chemically cross-linked polyethylene bonds into a heat-resistant dielectric retaining properties at the 90 °C operating temperature.
Sheath PVC, flame-retardant class C (ZC) — An overall PVC jacket binds the heavy 3+1 bundle and carries the class C flame-retardant formulation; deep moss green finish.
Flame retardancy ZC class C (self-extinguishing, not fire-rated) — On removal of a flame the cable stops propagating fire; this is flame retardancy, not 950 °C/180 min circuit-integrity fire resistance.
Suitable for Main motor, plant feeder, large equipment — Designed for fixed large three-phase motors, workshop distribution feeders and heavy equipment supply circuits.
Application 380V main motor / plant feeder supply — Typically runs from a main switchboard or MCC to a large motor, compressor, furnace or workshop distribution board.
Application note Not for 950°C circuit-integrity fire duty — Do not substitute this ZC cable for a mineral-insulated or fire-resistant circuit; it cannot maintain live integrity under sustained fire.
02 · Conductors
Phase cores count / area 3 × 150 (L1/L2/L3) mm² Three 150 mm² phase conductors carrying the heavy main motor or feeder load current.
Neutral core count / area 1 × 70 (N) mm² One 70 mm² neutral conductor sized for the feeder neutral return on predominantly balanced large loads.
Conductor type Compacted stranded Cu, Class 2 — Class 2 stranded compacted construction gives fixed-wiring conductors that round into stable heavy bundles for lug termination.
DC resistance (150 phase) @ 20°C ≤ 0.124 Ω/km Maximum permitted DC resistance of a 150 mm² copper phase conductor at 20 °C, applied to L1/L2/L3.
DC resistance (70 neutral) @ 20°C ≤ 0.268 Ω/km Maximum permitted DC resistance of the 70 mm² neutral conductor at 20 °C; higher than phases by design of the reduced neutral.
Stranding Layer-compacted concentric bundle — Concentric layers of strands are compacted radially per core to reduce gaps, tighten the heavy bundle and present a clean round lug entry.
Strands (nom., est.) 150 ≈37; 70 ≈19 strands per core — Approximate compacted strand counts; exact count follows the conductor standard for each section.
Surface Bare copper; tinned optional — Bare copper suits most indoor use; optional tinned plating improves corrosion resistance in damp or chemically mild sites.
Core identification L1/L2/L3 phase colors + N neutral — Phase cores and the neutral are color-coded so phase sequence and neutral match at the MCC or motor terminal box.
Neutral sizing logic Reduced neutral for balanced large loads — The 70 mm² neutral suits balanced three-phase heavy loads; enlarge the neutral where VFD/rectifier harmonics are high.
Compaction benefit Compact round bundle, tidy OD, clean crimp — Radial compaction reduces overall diameter versus loose stranding and gives a flat, even heavy-lug crimp on both sections.
03 · Insulation
Insulation material XLPE (cross-linked polyethylene) — Cross-linked PE delivers a higher continuous temperature rating and lower dielectric loss than PVC insulation for the same size.
Insulation thickness (150 phase, nom.) ≈ 2.4 mm Nominal radial insulation wall on each 150 mm² phase core; gauged to withstand the 3.5 kV routine test.
Insulation thickness (70 neutral, nom.) ≈ 2.2 mm Nominal insulation wall on the smaller 70 mm² neutral core, matched to its voltage class.
Working conductor temp. 90 °C Maximum continuous conductor temperature under rated current without shortening insulation life.
Short-circuit temp. 250 °C Peak conductor temperature the insulation may survive for a short fault duration (seconds) before damage occurs.
Insulation resistance High and stable MΩ·km XLPE keeps a high, stable insulation resistance over life, supporting reliable earth-fault detection on heavy feeders.
Color L1/L2/L3/N color on request — Insulation colors are matched to local 3-phase convention or supplied natural with printed marking.
Cure type Chemical / dry-cured XLPE — A controlled cross-linking cure locks the polymer network so the insulation stays elastic rather than melting under heat.
04 · Sheath & Flame Retardancy
Sheath material PVC, flame-retardant ZC — The class C PVC outer jacket blends a flame-suppressing formulation while keeping a smooth, printable surface.
Sheath thickness (nom.) ≈ 2.2 mm Nominal overall jacket wall sized to shield the heavy 3+1 bundle from abrasion and mechanical handling.
Finished outer diameter ≈ 34 mm Heavy overall 3+1 finished diameter used to size glands, trunking and large conduit on feeder runs.
Flame behavior Self-extinguishing, class C — After the test flame is removed the sample extinguishes without propagating; it is not 950°C fire-rated.
Sheath color Deep moss green (black/gray on request) — Standard deep moss green; black or dark gray jackets are supplied for industrial aesthetics on request.
Surface finish Smooth, continuous print — A smooth jacket carries a continuous printed line of type, size, voltage, ZC class and meter length along its length.
05 · Electrical
Rated voltage (U0/U) 0.6/1 kV Low-voltage rating matching 380/400 V main-motor and plant feeder systems.
Max voltage (Um) 1.2 kV Continuous upper system voltage for phase-to-earth insulation stress.
Nominal current (per 150 phase, est.) ≈ 300 A Approximate ampacity of a 150 mm² phase core in free air at 30 °C; reduce for conduit fill and high ambient.
Test voltage (AC) 3.5 kV / 5 min — Routine dielectric withstand applied between each conductor and sheath for five minutes without breakdown.
Insulation resistance High, XLPE MΩ·km Measured after conditioning; confirms no void, crack or contamination in the cured insulation.
Short-circuit current (150 phase, 1s, est.) ≈ 15 kA Approximate 1-second copper short-time withstand on the 150 mm² phase core; heavy feeder fault coordination.
Frequency 50 / 60 Hz Compatible with both 50 Hz and 60 Hz three-phase power systems.
Dielectric XLPE, low loss — Low dielectric loss keeps heating down under continuous heavy feeder duty.
06 · Thermal & Environment
Normal conductor temp. 90 °C Sustained operating temperature the XLPE insulation is rated for under full load.
Installed ambient 0 ~ +40 °C Recommended continuous ambient around the cable; crowded trays and ducts require ampacity derating.
Min install temp. 0 °C Avoid cold bending below 0 °C where the PVC jacket and insulation may stiffen and crack.
Burning Self-extinguishing, ZC class C — Class C vertical flame test behavior: flame stops once the external burner is removed.
Outdoor / UV Indoor preferred; UV-grade jacket optional — Standard PVC degrades under prolonged direct sun; specify UV-stabilized jacket for exposed outdoor feeder runs.
Oil / chemicals Resistant to common oils; check aggressive media — Withstands typical industrial oils; verify against specific solvents, cleaning agents or acid fumes before use.
Temperature cycle Withstands repeated 0~90°C duty — The insulation and jacket survive repeated motor start-stop and feeder switching cycles without cracking.
07 · Mechanical & Construction
Min bending radius (fixed) ≥ 15 × OD ≈ 510 mm Fixed-installation minimum bend radius for the heavy 3+1 cable; requires adequate bend allowance in ducts.
Flexibility Stranded, hand/equipment bent on feeder — Compact strands remain workable for tray and duct routing; heavy sections need bending tools.
Shielding / Armor None / unarmored (armor optional) — No braid screen and no armor as standard; add braid screen near VFD EMI; steel-tape armor for ground-crushing ducts.
Cable weight per km (est.) ≈ 5600 kg/km Heavy mass per kilometer used for tray load, drum rating and rigging planning.
Circularity Compact 3+1 bundle, heavy OD — Three phases around the reduced neutral form a compact round bundle after sheathing.
Tensile / elongation Jacket meets PVC grade — Jacket tensile strength and elongation satisfy the PVC compound grade for routine pulling.
08 · Factory Advantages
Heavy balanced 3+1 sizing 3×150 phases with 1×70 neutral for large loads — Right-sized reduced neutral avoids excess copper cost on balanced heavy three-phase feeders.
Stable XLPE cure Even cross-linking keeps the 90°C dielectric consistent — Controlled cure prevents soft spots in the thick insulation under sustained heavy load.
Dosed ZC compound Flame-retardant PVC self-extinguishes to class C — Self-extinguishing jacket protects switchrooms and workshop wiring spaces.
Length-on-demand Cut to exact feeder meter, sealed ends — Custom cut lengths match the measured main feeder and motor route.
Dual-section resistance log Phase 150 and neutral 70 R logged to lot — Both conductor sections are recorded for incoming inspection and batch traceability.
Continuous print line Type, size, ZC, voltage and length along jacket — Clear continuous marking lets installers read phase and neutral section along long feeder runs.
Phase-color option L1/L2/L3/N insulation colors matched to convention — Pre-colored cores reduce wiring errors at MCC blocks and large motor boxes.
Heavy drum pack Standard wooden drum with sealed ends — Heavy section wound on a rated drum; ends sealed against moisture during transport.
Certified QA pack Routine + type test record shipped per batch — A complete QA packet supports buyer inspection and feeder commissioning sign-off.
09 · Installation
Laying Main motor, plant feeder, large equipment — Route in trays, large conduit, duct or direct burial with armor; keep the 3+1 bundle round and observe bend radius.
Connectors 150 mm² phase lugs; 70 mm² neutral lug — Crimp 150 mm² lugs on L1/L2/L3 and a 70 mm² lug on N; select heavy glands sized to ≈34 mm OD.
Bend radius ≥ 15×OD ≈ 510 mm — Maintain the minimum radius around duct elbows and switchboard entries to avoid insulation stress.
Parallel runs Derating in bundles and ducts — Adjacent loaded cores share heat; apply derating factors before selecting the feeder breaker.
Site test Continuity + insulation post-laying — After pulling, verify three-phase continuity, phase sequence, neutral continuity and insulation resistance.
Termination Strip, hydraulic crimp, torque per table — Strip insulation without nicking strands, use matched heavy dies on each lug, and torque per the lug table.
10 · Packing & Applications
Supply length Custom / wooden drum m Cut to the measured feeder length on a rated wooden drum.
Length tolerance Per trade standard for cut lengths — Cut-length tolerance follows the applicable trade standard rather than a fixed meter promise.
Reel type Standard wooden drum — Heavy section wound on a rated drum; ends sealed against moisture.
Surface marking ZC-YJV, 3×150+1×70, 0.6/1kV, ZC, length — Jacket prints type, phase/neutral section, voltage, flame class and cumulative meter length.
Typical use Main motor, compressor, workshop feeder, large equipment — Large three-phase motors, compressors, furnaces, workshop distribution feeders and heavy equipment supplies.
Storage Dry indoor on drum supports, avoid UV — Store horizontally on timber supports, dry and shaded; keep ends sealed until installation.


Cable Test Parameters


Test Parameters — ZC-YJV 3×150+1×70 LV Flame-Retardant 3+1 Cable 
No. Test Item Test Condition / Method Requirement Type
1 DC resistance (150 phase) 20 °C, L1/L2/L3 (150 mm²) ≤0.124 Ω/km Routine
2 DC resistance (70 neutral) 20 °C, N (70 mm²) ≤0.268 Ω/km Routine
3 Voltage test (AC) 3.5 kV AC, 5 min, core-to-sheath No breakdown Routine
4 Insulation resistance XLPE, 20°C, per core High & stable Routine
5 Continuity 3 phases + neutral Continuous Routine
6 Flame retardancy Class C vertical test Self-extinguish Type
7 Sheath thickness Micrometer, cross-section Nominal ≈2.2 mm Routine
8 Phase insulation thickness Micrometer, 150 mm² cores Nominal ≈2.4 mm Routine
9 Neutral insulation thickness Micrometer, 70 mm² core Nominal ≈2.2 mm Routine
10 Dimensional check Caliper, overall OD OD ≈ 34 mm Routine
11 Conductor construction Visual / strand count per core Class 2 compacted Routine
12 Short-circuit rating Calculated / type ≈15 kA / 1 s Type
13 Insulation eccentric test Cross-section measure per core Within tolerance Routine
14 Printing legibility Visual Marking readable Routine
15 Mass per unit length Weigh / calculate ≈ 5600 kg/km Routine
16 Packing & drum inspection Visual / drum and sealed ends Sealed ends, sound drum Routine


Cable Cross Section Structure


Copper Power Cable 4 Core ZR-YJV 3×150mm2+1×70mm2 For Power System

ZC-YJV 3×150+1×70 — 3+1 Cross-Section Construction Diagram 
3×150 phase Cu + 1×70 neutral Cu / XLPE insulation / PVC ZC sheath · 0.6/1 kV · ZC class C · ≈34 mm · main motor, plant feeder & large equipment supply
No. Layer / Feature Material / Construction Nominal Thickness (mm) Diameter (mm) Detailed Function / Remarks
1 Conductor L1 — phase 1×150 compacted Cu, Class 2, ≈37 strands — ≈ 16.0 Phase 1 core, DC R ≤0.124 Ω/km @20°C; heavy feeder current.
2 Conductor L2 — phase 1×150 compacted Cu, Class 2, ≈37 strands — ≈ 16.0 Phase 2 core, equal size/resistance for balanced three-phase.
3 Conductor L3 — phase 1×150 compacted Cu, Class 2, ≈37 strands — ≈ 16.0 Phase 3 core, equal spec; color-coded for phase sequence.
4 Conductor N — neutral 1×70 compacted Cu, Class 2, ≈19 strands — ≈ 11.5 Reduced neutral, R ≤0.268 Ω/km; balanced heavy-load neutral return.
5 Strand compaction Concentric layers rolled compact per core — — Radial compaction closes gaps for a compact heavy bundle and clean lugs.
6 XLPE insulation (150 phase) Dry-cured cross-linked PE, ≈2.4 mm ≈ 2.4 ≈ 20.8 90°C phase dielectric; low loss, passes 3.5 kV routine test.
7 XLPE insulation (70 neutral) Dry-cured cross-linked PE, ≈2.2 mm ≈ 2.2 ≈ 15.9 Neutral dielectric matched to the smaller 70 mm² section.
8 3+1 core laying 3 phases around 1 reduced neutral — — Heavy 3+1 arrangement settles into a stable round finished form.
9 PVC ZC sheath Class C jacket, ≈2.2 mm ≈ 2.2 ≈ 34 Binds the heavy bundle; self-extinguishes to class C; moss-green finish.
10 Jacket print Continuous type/size/voltage/length line — — Marking: ZC-YJV, 3×150+1×70, 0.6/1kV, ZC, cumulative length.
Key Dimensions, Electrical & Mechanical Properties (expanded)
Finished cable diameter ≈ 34 mm Heavy 3+1 feeder OD for large glands, trunking and duct.
Approx. cable mass (est.) ≈ 5600 kg/km Heavy feeder mass; rated drum and tray load needed.
Nominal voltage rating 0.6/1 kV Matches 380/400 V main-motor systems.
Max voltage (Um) 1.2 kV Phase-to-earth continuous upper limit.
Normal conductor temp. 90 °C Continuous load temperature of XLPE.
Short-circuit temp. 250 °C Short-time fault peak before insulation damage.
DC resistance (150 phase) ≤ 0.124 Ω/km Per phase core @20°C.
DC resistance (70 neutral) ≤ 0.268 Ω/km Reduced neutral @20°C.
Neutral sizing 1×70 reduced neutral — For balanced heavy loads; enlarge on high harmonics.
Nominal phase current (est.) ≈ 300 A Per 150 phase core, free air 30°C; derate in duct.
Short-circuit rating (1s, est.) ≈ 15 kA Heavy feeder fault coordination duty.
Flame retardancy ZC class C, self-extinguishing — Not 950°C fire-rated.
Min bending radius (fixed) ≥ 15 × OD ≈ 510 mm Duct and switchboard bend allowance.
Frequency 50 / 60 Hz Compatible with both power systems.
Insulation resistance High & stable MΩ·km XLPE; supports earth-fault detection.
Dielectric loss Low — XLPE limits heating on heavy feeder duty.
Temperature cycle 0~90°C repeated — Survives start-stop and switching cycling.
Sheath mechanical Jacket meets PVC grade — Tensile/elongation checked at type test.
Pack choice Rated wooden drum — Heavy section with sealed ends.
Application Main motor, compressor, workshop feeder — 380/400 V large motors, furnaces and distribution feeders.
Schematic — not to exact scale. OD ≈34 mm, weight ≈5600 kg/km, phase ampacity ≈300 A free air at 30°C and ≈15 kA/1s are (est.) from cross-referenced industry samples. ZC-YJV 3×150+1×70 serves 380/400 V main motors, workshop feeders and large equipment; ZC class C self-extinguishes but is not 950°C fire-rated. Estimated values require confirmation against the factory test certificate for the specific batch.


Cable Construction Description


Construction Description — ZC-YJV 3×150+1×70 LV flame-retardant 3+1 cable 
3×150 phase Cu + 1×70 neutral Cu / XLPE insulation / PVC ZC sheath · 0.6/1 kV · ZC class C · 90°C · ≈34 mm · main motor, plant feeder & large equipment
1. Product Identity & Ratings
ZC-YJV 3×150+1×70 rated 0.6/1 kV (Um 1.2), 90°C working, ZC class C; three 150 mm² phase cores plus one 70 mm² neutral in a heavy 3+1 lay. OD ≈34 mm, ≈5600 kg/km (est.), ≈300 A per phase free air at 30°C (est.), rated wooden drum. It is a fixed main feeder cable, not a flexible cord and not a 950°C fire-rated circuit.
2. Copper Conductors (3×150 phase + 1×70 neutral)
Three compacted Class 2 Cu phase cores (L1/L2/L3), R ≤0.124 Ω/km @20°C, plus one 70 mm² neutral, R ≤0.268 Ω/km @20°C; reduced neutral suits balanced heavy loads; tinned plating optional; phase-color insulation on request.
3. Strand Compaction & 3+1 Bundle
Concentric strands are rolled compact per core to close gaps and give clean heavy-lug entry; three phases surround the reduced neutral to form a stable round heavy 3+1 bundle before sheathing.
4. XLPE Insulation
Dry-cured cross-linked PE ≈2.4 mm on phases and ≈2.2 mm on the neutral; stable 90°C dielectric, low dielectric loss, high insulation resistance; short-circuit peak 250°C; matched wall per section.
5. Core Identification
L1/L2/L3 phases and the N neutral are identified by insulation color; the smaller neutral section distinguishes it at the MCC terminal block or large motor box.
6. PVC ZC Sheath
Class C flame-retardant PVC ≈2.2 mm overall, self-extinguishing; deep moss green standard (black/gray on request); smooth printable surface; binds the heavy bundle and shields from industrial abrasion.
7. Electrical Characteristics
0.6/1 kV, Um 1.2; phase R ≤0.124, neutral R ≤0.268 Ω/km; routine 3.5 kV AC/5 min; ≈300 A per phase (est., air 30°C); short-circuit ≈15 kA/1s (est.); 50/60 Hz; unscreened; low-loss XLPE.
8. Factory Advantages
• Heavy balanced 3+1 sizing.  • Stable XLPE cure.  • Dosed ZC self-extinguish.  • Length-on-demand.  • Dual-section resistance log.  • Continuous clear print.  • Phase-color option.  • Rated drum pack.  • Certified QA pack.
9. Site Handling & Installation
• Bend 15×OD (≈510 mm).  • 150 mm² phase lugs, 70 mm² neutral lug, glands to ≈34 mm OD, hydraulic crimp, torque per table.  • Duct/bundle derating.  • Keep 3+1 bundle round.  • Three-phase continuity, sequence, neutral + insulation after pulling.
10. Typical Service Applications
380/400 V large three-phase motors, compressors, furnaces, workshop distribution feeders, MCC-to-equipment heavy supplies and industrial plant feeder circuits.
11. Testing & QA
16-item regime: routine phase DC resistance (150), neutral DC resistance (70), 3.5 kV withstand, insulation resistance, 3-phase+neutral continuity, phase/neutral insulation thickness, sheath thickness, dimensional check, strand construction, eccentricity, print legibility, mass, packing inspection; type ZC flame, short-circuit, sheath mechanical.
12. Packaging, Storage & Notes
Cut to measured feeder length on a rated wooden drum with sealed ends; continuous marking; store dry indoor on drum supports, shaded, avoid direct UV. Est. OD/weight/ampacity/short-circuit confirmed against the factory certificate; ZC is flame retardant, not 950°C fire-rated.


8. Factory Advantages.

  • Heavy balanced 3+1 sizing — 3×150 phases with 1×70 neutral, cost-effective on balanced heavy feeders.
  • Stable XLPE cure — even cross-linking keeps the 90°C dielectric consistent under sustained load.
  • Dosed ZC compound — self-extinguishing jacket protects switchrooms and wiring spaces.
  • Length-on-demand — cut to exact feeder meter with sealed ends.
  • Dual-section resistance log — phase 150 and neutral 70 R logged to lot.
  • Continuous print line — type, size, ZC, voltage and length along long jacket runs.
  • Phase-color option — L1/L2/L3/N colors reduce MCC wiring errors.
  • Rated drum pack — heavy section wound on a rated drum with sealed ends.
  • Certified QA pack — routine + type test record shipped per batch.

Copper Power Cable 4 Core ZR-YJV 3×150mm2+1×70mm2 For Power System


9. Packaging, Storage & Logistics. Cut to measured feeder length on a rated wooden drum with sealed ends; continuous marking; store dry indoor on drum supports, shaded, avoid direct UV.


Copper Power Cable 4 Core ZR-YJV 3×150mm2+1×70mm2 For Power System


10. Procurement Specification. State "ZC-YJV 3×150+1×70", length, class C, phase colors, braid screen near VFD EMI, or steel-tape armor for crushing ducts; note reduced neutral for balanced heavy loads and not fire-rated; request dual-section resistance log and the 16-item QA record. Est. values confirmed against the factory certificate.


11. Cable Industry FAQ.

  • Q1: How does 3×150+1×70 differ from 3×25+1×16? Major size-up: phases 150 vs 25 mm², neutral 70 vs 16 mm²; much heavier OD (34 vs 12 mm), heavier mass (5600 vs 760 kg/km), far higher current (300 vs 78 A), much lower resistance (0.124/0.268 vs 0.741/1.15 Ω/km); serves main feeders rather than small control branches.
  • Q2: Why a reduced 70 mm² neutral? Balanced large three-phase loads draw little neutral current, so a 70 mm² neutral saves copper; enlarge it under VFD/rectifier harmonic duty.
  • Q3: Is ZC fire-resistant? No. Class C self-extinguishes; it does not hold live at 950°C/180min.
  • Q4: DC resistance values? Phase 150 ≤0.124 Ω/km; neutral 70 ≤0.268 Ω/km at 20°C.
  • Q5: Screen or armor? Unscreened standard; add braid screen near VFD EMI; steel-tape armor for ground-crushing ducts or direct burial.
  • Q6: Current per phase? ≈ 300 A (est.) free air 30°C; derate in crowded ducts and trays.
  • Q7: Bending? ≥ 510 mm (15×OD); plan bend allowance at duct elbows and boards.
  • Q8: Connectors? 150 mm² phase lugs, 70 mm² neutral lug, heavy gland to ≈34 mm OD.
  • Q9: Indoor or outdoor? Indoor preferred; specify UV-stabilized jacket for exposed outdoor feeder runs.
  • Q10: Packing? Rated wooden drum with sealed ends.
  • Q11: What proof ships? Dual-section resistance log + 16-test record; est. values confirmed against certificate.