"polyvinyl chloride pvc or low smoke zero halogen lszh medium voltage power cable"
- 11 Items Found
Building Power Distribution 2 Core Power Cable Braided Flex Oxygen Free Copper
ZR-YJV 2*10mm² Flame Retardant 2 Core Power Cable,0.6/1kV Oxygen-Free Copper,XLPE Insulation PVC Sheath for Building Power Distribution Code Mean:ZR-Flame Retardant,YJ-XLPE Insulation,V-PVC Outer Sheathed. ZR-YJV 2×10 mm² — Technical Description 1. Product Class. The ZR-YJV 2×10 is a two-core flame...
ZR-YJV 4×35mm² Flame Retardant Copper Power Cable, 0.6/1kV XLPE Insulated PVC Sheath
ZR-YJV 4×35mm² Flame Retardant Copper Power Cable, 0.6/1kV XLPE Insulated PVC Sheath Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×35 mm² Four equal cores of 35 mm² copper conductor Construction ...
0.6/1kV ZC-YJV 3x70+1x35mm² Copper XLPE PVC Flame-Retardant Power Cable for Transformer Room LV Outgoing Circuits
0.6/1kV ZC-YJV 3x70+1x35mm² Copper XLPE PVC Flame-Retardant Power Cable for Transformer Room LV Outgoing Circuits Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 3×70 mm² + 1×35 mm² Three phase ...
4+1 Core 4*16mm² + 1*10mm² Copper Power Cable ZR-YJV XLPE Flame Retardant 0.6/1kV
4+1 Core 4*16mm² + 1*10mm² Copper Power Cable ZR-YJV XLPE Flame Retardant 0.6/1kV Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×16 mm² + 1×10 mm² Four cores of 16 mm² (3 phase + 1 neutral) + one ...
Flame Retardant Power Cable ZR-YJV 3×70mm²+1×35mm² for Industrial Power Distribution
Flame Retardant Power Cable ZR-YJV 3×70mm²+1×35mm² for Industrial Power Distribution Cable Designation & Meaning Code Meaning ZR Legacy prefix for flame retardant; under GB/T 19666-2019 it defaults to Class C (modern equivalent: ZC). YJ XLPE (cross-linked polyethylene) insulation V PVC outer sheath ...
ZR-YJV 4×50mm² 0.6/1kV Flame Retardant Copper Cable, XLPE Insulation for Building Power Distribution
ZR-YJV 4×50mm² 0.6/1kV Flame Retardant Copper Cable, XLPE Insulation for Building Power Distribution Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×50 mm² Four equal cores of 50 mm² copper ...
ZR-YJV 4×70mm² 0.6/1kV Flame Retardant Copper Cable, XLPE Insulation for Building Power Distribution
ZR-YJV 4×70mm² 0.6/1kV Flame Retardant Copper Cable, XLPE Insulation for Building Power Distribution Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×70 mm² Four equal cores of 70 mm² copper ...
Stranded Copper 2 Core Flexible Cable Wire RVV 4x6.0mm2 PVC Flexible 300V 500V
Stranded Copper Wire 4 Core Cable RVV 4x6.0mm² PVC Flexible 300/500V Cable Designation & Meaning Code Meaning RVV R = Flexible copper conductor (Class 5), V = PVC insulation, V = PVC sheath 300/500 V Rated voltage U₀/U = 300/500 V; Uₘ = 500 V 4×6.0 mm² Four flexible cores, each 6.0 mm² copper ...
Earth 5 Cores Cable 4x70mm2+1x35mm2 XLPE Copper Flame Retardant 600 1000V
5 Core + Earth Cable ZR-YJV 4x70mm²+1x35mm² XLPE Copper Flame Retardant 0.6/1kV Cable Designation & Meaning Code Meaning ZC Flame retardant Class C YJ Cross-linked polyethylene (XLPE) insulation V Polyvinyl chloride (PVC) sheath 4×70 mm² + 1×35 mm² Four cores of 70 mm² (3 phase + 1 neutral) + one ...