logo
Anhui Tongdu International Trade Co., Ltd.
Çevrimiçi Hizmet

Çevrimiçi Hizmet

İlgili kişi
+86 19056002718
WeChat QR kodu
Bizi takip edin.
No Products Found Matching Your Search Criteria:

"polyvinyl chloride pvc or low smoke zero halogen lszh medium voltage power cable"

Please try a different search term or browse our product categories.

Recommend Other Products
Kalite Kırmızı Masif Bakır İletken PVC Yalıtımlı Tek Damarlı Bakır Faz Kablosu Fabrika

Kırmızı Masif Bakır İletken PVC Yalıtımlı Tek Damarlı Bakır Faz Kablosu

Red BV 2.5mm² PVC Insulated Single Core Copper Live Wire 450/750V Electrical Building Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain copper ...

Kalite H1Z2Z2-K 4.0mm2 Fotovoltaik Güneş Kablosu TUV 1500V XLPE Bakır Kablo Fabrika

H1Z2Z2-K 4.0mm2 Fotovoltaik Güneş Kablosu TUV 1500V XLPE Bakır Kablo

H1Z2Z2-K 4.0mm² TUV 1500V DC Solar Cable UV Resistant Halogen Free XLPE Copper Cable Designation & Meaning Code Meaning H Harmonized cable (H) 1 Rated voltage 1 kV AC (U₀/U = 1/1 kV reference) Z Halogen-free compound (Z = halogen-free) 2 Insulation layer — cross-linked halogen-free compound (XLPO) Z ...

Kalite PV Kablosu PV1-F 4.0mm2 TUV UV Dirençli Hava Duruma Dayanıklı 1500V DC Fotovoltaik Fabrika

PV Kablosu PV1-F 4.0mm2 TUV UV Dirençli Hava Duruma Dayanıklı 1500V DC Fotovoltaik

PV Cable PV1-F 4.0mm² TUV UV Resistant Weatherproof 1500V DC Photovoltaic Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 4.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper conductor, ...

Kalite Güneş Paneli Bağlantı Kablosu PV1-F 4.0mm² TUV 1500V DC Hava Koşullarına Dayanıklı PV Kablosu Fabrika

Güneş Paneli Bağlantı Kablosu PV1-F 4.0mm² TUV 1500V DC Hava Koşullarına Dayanıklı PV Kablosu

Solar Panel Connection Cable PV1-F 4.0mm² TUV 1500V DC Weatherproof PV Wire Cable Designation & Meaning Code Meaning PV Photovoltaic (solar) application 1 Single-core F Flexible conductor (Class 5 fine-stranded) 4.0 mm² Nominal cross-sectional area of conductor Construction : Tinned copper conductor...

Kalite Hafif Alüminyum Kablo 3 çekirdek 35mm2 YJLV22 8.7/10kV Zırhlı XLPE Fabrika

Hafif Alüminyum Kablo 3 çekirdek 35mm2 YJLV22 8.7/10kV Zırhlı XLPE

Lightweight Aluminum Cable 3 Core 35mm² YJLV22 8.7/10kV Armored XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor ​ (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...

Kalite Süper Ağır MV Kablosu YJV22 3x300mm2 8.7/15kV Zırhlı XLPE Güç Kablosu Fabrika

Süper Ağır MV Kablosu YJV22 3x300mm2 8.7/15kV Zırhlı XLPE Güç Kablosu

Super Heavy MV Cable YJV22 3x300mm² 8.7/15kV Armored XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 kV...

Kalite 3 Çekirdekli Zırhlı YG Kablo YJV22 3x50mm² 8.7/10kV 8.7/15kV XLPE Güç Kablosu Fabrika

3 Çekirdekli Zırhlı YG Kablo YJV22 3x50mm² 8.7/10kV 8.7/15kV XLPE Güç Kablosu

3 Core Armored MV Cable YJV22 3x50mm² 8.7/10kV 8.7/15kV XLPE Power Cable Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV Rated voltage U₀/U = 8.7/10 ...

Kalite Büyük Yangına Hazır Tel 4x95mm2+1x70mm2 Mineral İzolasyonlu Isıtma Kablosu Fabrika

Büyük Yangına Hazır Tel 4x95mm2+1x70mm2 Mineral İzolasyonlu Isıtma Kablosu

Large Fire Cable BTTRZ 4x95mm²+1x70mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV ...