"polyvinyl chloride pvc or low smoke zero halogen lszh medium voltage power cable"
Please try a different search term or browse our product categories.
2.5mm2 고체 구리 전도기 땅 고체 토양 불 retardant
Yellow Green BV 2.5mm² Ground Earth Wire PVC Insulated Copper Cable Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain copper conductor (solid or stranded)...
전선관 설치용 블랙 BV 2.5mm2 단선 구리 코어 Cu PVC 와이어
Black BV 2.5mm² Solid Copper Conductor PVC Wire for Conduit Installation Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire) V PVC (polyvinyl chloride) insulation 2.5 mm² Nominal cross-sectional area of conductor Construction: Plain copper conductor (solid or ...
1500V 태양광 PV 케이블 알로겐 없는 5급 유연한 PV 광전자 유선
H1Z2Z2-K 6.0mm² TUV 1500V DC Solar Main Cable UV Resistant PV Photovoltaic Wire Cable Designation & Meaning Code Meaning H Harmonized cable (H) 1 Rated voltage 1 kV AC (U₀/U = 1/1 kV reference) Z Halogen-free compound (Z = halogen-free) 2 Insulation layer — cross-linked halogen-free compound (XLPO) ...
TUV 1kV 태양광 케이블 H1Z2Z2-K 4mm2 Pv 케이블
1500V DC Solar Wire H1Z2Z2-K 4.0mm² TUV XLPE Photovoltaic Cable Cable Designation & Meaning Code Meaning H Harmonized cable (H) 1 Rated voltage 1 kV AC (U₀/U = 1/1 kV reference) Z Halogen-free compound (Z = halogen-free) 2 Insulation layer — cross-linked halogen-free compound (XLPO) Z Halogen-free ...
4.0mm2 TUV 광전자 케이블 1500V 비성식 광전자 유선
H1Z2Z2-K 4.0mm² TUV Certified Solar Cable 1500V DC Photovoltaic Wire Cable Designation & Meaning Code Meaning H Harmonized cable (H) 1 Rated voltage 1 kV AC (U₀/U = 1/1 kV reference) Z Halogen-free compound (Z = halogen-free) 2 Insulation layer — cross-linked halogen-free compound (XLPO) Z Halogen...
8.7KV 10kV Mv 전력 케이블 장갑 마천루 메인 알루미늄 케이블
Skyscraper Main Aluminum Cable YJLV22 3x400mm2 8.7/10kV 8.7/15kV Armored MV Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 ...
?
Lightweight Aluminum Cable 3 Core 35mm² YJLV22 8.7/10kV Armored XLPE Cable Designation & Meaning Code Meaning YJ XLPE (cross-linked polyethylene) insulation L Aluminium conductor (Al) V PVC inner bedding / outer sheath 22 Steel tape armour (double steel tape, overlapping) + PVC sheath 8.7/10 kV ...
4x70mm2 + 1x50mm2 방화 케이블 1KV 1.2KV 광물 단열 케이블
Heavy Duty Fire Cable BTTRZ 4x70mm²+1x50mm² Mineral Insulated 0.6/1kV Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV Rated ...