Fire Resistant Cable
BTTRZ X50mm2+1x25mm2 Fire Resistant Cable Mineral Emergency Power Copper Sheathed Cable
BTTRZ x50mm²+1x25mm² Mineral Insulated Fire Resistant Copper Sheathed Cable for Emergency Power Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire/power cable) T Copper conductor (Tong = copper) T Copper sheath (Tong = copper) R Flexible (Rou = flexible) Z Heavy ...
BTLY Fire Rated Cable 4x35mm2 + 1x16mm2 Aluminum Sheath Cable For Emergency
NG-A BTLY 4x35+1x16mm2 Mineral Insulated Fire Resistant Aluminum Sheath Cable for Emergency Cable Designation & Meaning Code Meaning NG-A New Generation A-class fire-resistant (Chinese designation) (BTLY) Building wire, Thin copper conductor, Lightweight Y— alternative naming convention indicating: ...
4x185mm2+1x195mm2 Fire Resistant Cable 0.6KV 1KV Mineral Insulated Copper Cable
Super Fire Cable BTTRZ 4x185mm²+1x95mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ Flexible mineral-insulated copper-sheathed fire-resistant cable 4×185 mm² Four cores of 185 mm² copper conductor (3 phase + 1 neutral) +1×95 mm² One core of 95 mm² copper ...
BTTRZ Flame Retardant Cable 4x150mm2+1x70mm2 Mineral Insulated Cable
Ultra Fire Cable BTTRZ 4x150mm²+1x70mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ Flexible mineral-insulated copper-sheathed fire-resistant cable 4×150 mm² Four cores of 150 mm² copper conductor (3 phase + 1 neutral) +1×70 mm² One core of 70 mm² copper ...
4+1 Core Fire Resistant Cable 120mm2+1x70mm2 BTTRZ Fire Substation Cable
Fire Substation Cable 4+1 Core 120mm²+1x70mm² BTTRZ Fire Resistant Mineral Insulated Cable Designation & Meaning Code Meaning BTTRZ Flexible mineral-insulated copper-sheathed fire-resistant cable 4×120 mm² Four cores of 120 mm² copper conductor (3 phase + 1 neutral) +1×70 mm² One core of 70 mm² ...
Large Fire Rated Wire 4x95mm2+1x50mm2 Mineral Insulated Heating Cable
Large Fire Cable BTTRZ 4x95mm²+1x50mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ Flexible mineral-insulated copper-sheathed fire-resistant cable 4×95 mm² Four cores of 95 mm² copper conductor (3 phase + 1 neutral) +1×50 mm² One core of 50 mm² copper ...
4x70mm2+1x35mm2 Fire Resistant Cable 1KV 1.2KV Bare Copper Mineral Insulated Cable
Heavy Duty Fire Cable BTTRZ 4x70mm²+1x35mm² Mineral Insulated 0.6/1kV Cable Designation & Meaning Code Meaning BTTRZ Flexible mineral-insulated copper-sheathed fire-resistant cable 4×70 mm² Four cores of 70 mm² copper conductor (3 phase + 1 neutral) +1×35 mm² One core of 35 mm² copper conductor ...
Hospital Critical Fire Proof Cable Mineral 3200kg/Km Mi Heating Cable
Hospital Critical Cable BTTRZ 4x35mm²+1x16mm² Mineral Insulated Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV ...
25 Mm2 Fire Resistant Cable 4x25mm2+1x16mm2 Mineral Insulated Copper
0.6/1kV Mineral Insulated Cable BTTRZ 4x25mm²+1x16mm² Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV Rated ...