BTTRZ X50mm2+1x25mm2 Fire Resistant Cable Mineral Emergency Power Copper Sheathed Cable

BTTRZ X50mm2+1x25mm2 Fire Resistant Cable Mineral Emergency Power Copper Sheathed Cable

Basic Properties

country of origin
China
brand name
TONGDU
certificate
CE/ISO/CCC
product model
BTTRZ x50mm²+1x25mm²

Trading Properties

moq
1 Meter
payment method
L/C,T/T
supply capacity
100000 meters per month

Product Summary

BTTRZ x50mm²+1x25mm² Mineral Insulated Fire Resistant Copper Sheathed Cable for Emergency Power Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire/power cable) T Copper conductor (Tong = copper) T Copper sheath (Tong = copper) R Flexible (Rou = flexible) Z Heavy ...

Product Details

Highlight:

1x25mm2 fire resistant cable

,

fire resistant cable mineral

,

emergency power copper sheathed cable

Conductor (×4, phase/neutral):
Copper, Class 2 Stranded Flexible, Nominal 19×∅1.83 Mm (50 Mm²), Conductor Ø ≈ 9.2–10.5 Mm
Conductor (×1, earth):
Copper, Class 2 Stranded Flexible, Nominal 7×∅2.14 Mm (25 Mm²), Conductor Ø ≈ 6.4–7.2 Mm
Insulation:
Mineral (ceramic Compound / Magnesium Oxide Based), Inorganic, Non-combustible, Nominal Thickness 1.5 Mm (typical)
Separator:
Mica Tape Or Ceramic Paper Wrap Between Cores
Inner sheath:
Copper Tape/foil​ (continuous, Gas-tight), Thickness ≈ 0.3–0.5 Mm
Outer sheath:
LSZH (low-smoke Zero-halogen)​ Compound, Nominal Thickness 1.5 Mm (typical), Colour: Orange​ Or Red
Conductor nominal area:
50 Mm² (phase/neutral, ×4), 25 Mm² (earth, ×1)
Number of cores:
5
Conductor material:
Copper (Cu)
Conductor class:
Class 2 Stranded Flexible
Conductor construction:
19×1.83 Mm (50 Mm²), 7×2.14 Mm (25 Mm²)
Insulation thickness:
1.5 Mm
Copper inner sheath thickness:
0.3–0.5 Mm
Outer sheath thickness:
1.5 Mm
Overall cable diameter:
30 – 36 Mm
Design outer diameter:
≈ 33 Mm
Approx. weight:
3.8 – 4.6 Kg/m (3800–4600 Kg/km)
Design weight:
≈ 4150 Kg/km

Product Description

BTTRZ x50mm²+1x25mm² Mineral Insulated Fire Resistant Copper Sheathed Cable for Emergency Power

Cable Designation & Meaning

 

Code

Meaning

B

Fixed wiring cable (Class B — building wire/power cable)

T

Copper conductor (Tong = copper)

T

Copper sheath (Tong = copper)

R

Flexible (Rou = flexible)

Z

Heavy duty (Zhong = heavy)

4×50 mm² + 1×25 mm²

Four 50 mm² phase cores + one 25 mm² earth core (5-core: 3P+1N+1PE)

 

Construction: Copper conductors, mineral insulation (magnesium oxide or ceramic compound), copper sheath, flexible design with overall LSZH outer sheath.

 

BTTRZ X50mm2+1x25mm2 Fire Resistant Cable Mineral Emergency Power Copper Sheathed Cable

 

BTTRZ X50mm2+1x25mm2 Fire Resistant Cable Mineral Emergency Power Copper Sheathed Cable

 

BTTRZ 4×50+1×25 mm² (flexible mineral-insulated MgO Cu-sheathed fire-resistant cable) — Specification & Engineering Data 

1. Overview & Ratings. BTTRZ 4×50+1×25 — flexible mineral-insulated (MgO) copper-sheathed fire-resistant cable, four 50 mm² copper power cores (L1/L2/L3/N) plus one 25 mm² PE core, embedded in compacted magnesium oxide powder inside a continuous corrugated copper tube, rated 0.6/1 kV; built and tested per GB/T 13033 / BS 6387. The cable maintains circuit integrity at 950 °C for 180 minutes. Ø ≈ 38.5 mm, ≈ 3850 kg/km, wooden drums.

 

2. Construction Stack (Conductor → Outer).

Layer Build Wall Diameter
Conductors (×5) Cu: 4×50 mm² (L1/L2/L3/N) + 1×25 mm² (PE) — ≈ 9.5 / 6.3 mm
MgO insulation Magnesium oxide powder, compacted ≈ 1.5 around each —
Corrugated Cu tube Continuous welded copper ≈ 0.9 mm ≈ 36.5 mm
Outer PVC sheath PVC, black/red (corrosion protection) ≈ 1.0 mm ≈ 38.5 mm (finished)

 

3. Electrical Characteristics. R ≤ 0.387 Ω/km (50 mm²) / ≤ 0.741 Ω/km (25 mm²) at 20 °C; routine test 3.5 kV AC / 5 min; insulation resistance ≥ 1000 MΩ·km (MgO — extremely high). Reference ampacity ≈ 175 A (4×50 loaded, free air, 30 °C).

Insulation & Sheath Data

 

Property

Value

Insulation material

Mineral ceramic compound (inorganic, non-combustible)

Outer sheath material

LSZH (low-smoke zero-halogen)

Long-term service temp.

90 °C​ (continuous, limited by termination)

Short-circuit temp. (≤5 s)

1083 °C​ (Cu melting point, practical limit ~950 °C)

Emergency overload temp.

250 °C (short term, mineral insulation stable)

Fire survival temp.

950 °C for ≥ 180 min​ (BS 6387 CWZ)

Water resistance

Excellent (copper sheath is impermeable)

Radiation resistance

Excellent

Weather resistance

Excellent (copper sheath + LSZH outer)

Flame retardant

Inherent — non-combustible insulation & copper sheath

Smoke density

Zero (LSZH outer sheath)

Halogen content

Zero (mineral insulation + LSZH)

Electrical Parameters

 

Parameter

Value

Note

Rated voltage U₀/U

0.6 / 1 kV

GB/T 13033 / IEC 60702

Max. system voltage Uₘ

1.2 kV

—

Test voltage AC (5 min)

3.5 kV

Routine test

DC resistance @20 °C (50 mm²)

≤ 0.387 Ω/km

GB/T 3956 Class 2 Cu max

DC resistance @20 °C (25 mm²)

≤ 0.727 Ω/km

GB/T 3956 Class 2 Cu max

AC resistance @90 °C (est., 50 mm²)

≈ 0.493 Ω/km

per core

AC resistance @90 °C (est., 25 mm²)

≈ 0.924 Ω/km

earth core

Capacitance (approx.)

negligible

mineral insulation (near-zero permittivity)

Inductive reactance (approx.)

≈ 0.07 Ω/km

at 50 Hz, 5-core

Current rating in air (30 °C)

160 A​

3-phase loaded, 4×50 mm² (derated for 5-core)

Current rating buried (20 °C)

135 A​

direct buried (copper sheath excellent heat dissipation)

Current rating in conduit (30 °C)

125 A​

3-phase, 5-core

Short-circuit current (1 s, Cu, 250 °C)

≈ 5.0 kA (5000 A)

50 mm² Cu

Frequency

50/60 Hz AC

—

Reference values: 50 mm² Cu at 160 A, 3-phase 400 V → max balanced load ≈ 110 kVA. Voltage drop at 160 A ≈ 78.9 V/km per core (≈3.2% per 100 m at 400 V).

 

4. Thermal & Fire. 105 °C continuous conductor temperature (MgO allows higher than XLPE/PVC); short-circuit 250 °C; fire rating 950 °C / 180 min per BS 6387 class C — the cable remains energised during fire with impact and water spray. Zero toxic gas emission, zero halogen.

Temperature Characteristics

Property

Value

Max. conductor operating temp.

90 °C (continuous, termination limited)

Max. short-circuit temp. (≤5 s)

1083 °C (Cu melting point; practical 950 °C)

Emergency overload temp.

250 °C (mineral insulation stable)

Min. installation ambient temp.

−20 °C​ (LSZH sheath, flexible design)

Service ambient range

−20 °C to +90 °C (continuous); 950 °C fire survival​

Fire survival

BS 6387 Category CWZ​ — circuit integrity ≥ 180 min at 950 °C, water jet test (W), mechanical impact (Z)

Fire Performance (BTTRZ — Mineral Insulated, Fire Resistant)

 

Property

Value / Requirement

Flame retardant

Inherent​ — non-combustible (mineral insulation + copper sheath)

Halogen content

Zero​ (mineral ceramic + LSZH sheath)

Smoke density

Zero​ (IEC 61034, LSZH)

Corrosivity

Non-corrosive​ (IEC 60754)

Fire survival (circuit integrity)

BS 6387 CWZ​ — passes C (950 °C, 180 min), W (water jet during fire), Z (mechanical impact during fire)

Toxicity

Zero​ (inorganic materials)

Heat release

Near zero (non-combustible)

 

BS 6387 Classification:

 

Category

Test Condition

BTTRZ Result

C

950 °C, 180 min, circuit integrity

✅ Pass

W

Water jet during fire test

✅ Pass

Z

Mechanical impact during fire test

✅ Pass

 

5. Installation Practice & Handling. CRITICAL: install special MgO end seals at both ends — MgO is hygroscopic and absorbs moisture. Bend ≥ 12 × OD ≈ 460 mm fixed. Use Cu compression lugs + end sealing kits. The Cu tube is the primary fire barrier; the thin PVC outer sheath is only for corrosion protection.

Mechanical & Installation Parameters

 

Parameter

Value

Remarks

Minimum bending radius

≥ 6 × OD → ≈ 198 mm at Ø33 mm

flexible mineral cable

Max. pulling tension

5000 N

Cu conductor + Cu sheath

Direct burial

Excellent​ (copper sheath impermeable, no water ingress)

—

Conduit ID

≥ 1.5 × OD → ≥ 50 mm; use 63 mm or 75 mm

—

Fixing

copper-compatible clamps, cable ties

avoid galvanic corrosion with steel

Impact resistance

High​ (copper sheath provides mechanical protection)

—

Water resistance

Excellent​ (gas-tight copper sheath)

suitable for submerged/wet

UV resistance

Excellent​ (copper sheath + LSZH)

outdoor exposed

Termination note

Specialised MI cable terminations required​ — pot-type seals, compression glands, ceramic terminals

requires trained installer; cold-shrink or heat-shrink terminations available

 

6. Typical Service Applications. Fire pump power supply, emergency lighting circuits, smoke control systems, fire alarm circuits, evacuation signalling, critical life-safety power — any circuit that must remain operational during a fire.

 

BTTRZ X50mm2+1x25mm2 Fire Resistant Cable Mineral Emergency Power Copper Sheathed Cable

 

7. Testing & QA Regime. Routine: conductor DC resistance, 3.5 kV AC withstand, insulation resistance ≥ 1000 MΩ·km. Type: BS 6387 class C fire test (950 °C / 180 min with impact and water spray), crush resistance, halogen/toxicity test (zero), end seal integrity.

 

Cable Parameters

 

BTTRZ 4×50+1×25 mm² — Flexible Mineral-Insulated (MgO) Fire-Resistant Cu-Sheathed Cable — Full Parameter Sheet
Mineral-insulated fire-resistant cable · Cu conductors / MgO insulation / corrugated Cu tube / PVC outer sheath · 4×50 + 1×25 mm² · 0.6/1 kV · 950 °C 3h fire-rated · GB/T 13033 / BS 6387 · finished Ø ≈ 38.5 mm
Section Parameter Value Unit Remarks / Standard
01 · Identification
  Cable type BTTRZ (Flexible mineral-insulated Cu-sheathed fire-resistant cable) — Fire-resistant / emergency power
  Rated voltage (U0/U) 0.6/1 kV (Um=1.2 kV) Fire-rated power circuit
  Number of cores 4×50 + 1×25 — 3P+N+PE (PE=25 mm²)
  Conductor material Annealed copper — Class 1/2 per GB/T 3956
  Insulation material Magnesium oxide (MgO) — Mineral insulation, 950 °C
  Sheath material Corrugated copper tube + PVC outer — Cu tube = fire barrier
  Outer sheath colour Black / red — Fire cable identification
  Fire rating 950 °C / 180 min — BS 6387 class C
  Standard GB/T 13033 / BS 6387 — Mineral-insulated cable
02 · Conductor (Copper)
  Conductor type (power cores) Solid/stranded copper — Class 1/2 per GB/T 3956
  Conductor area (power) 4 × 50 mm² L1/L2/L3/N
  Conductor area (PE) 1 × 25 mm² Protective earth
  DC resistance @ 20 °C (50 mm²) ≤ 0.387 Ω/km Max per GB/T 3956
  DC resistance @ 20 °C (25 mm²) ≤ 0.741 Ω/km PE core
  Conductor weight per km ≈ 2240 kg/km 4×50 + 1×25 Cu
03 · Insulation & Sheath
  Insulation type Magnesium oxide (MgO) powder — Mineral, non-combustible
  Insulation thickness (around conductor) ≈ 1.5 mm MgO compacted
  Copper tube wall ≈ 0.9 mm Corrugated, continuous weld
  Outer PVC sheath ≈ 1.0 mm Corrosion protection
  Finished outer diameter ≈ 38.5 mm Cu tube + PVC
04 · Electrical
  Rated voltage (AC) 0.6/1 kV Fire-rated power
  DC resistance @ 20 °C (50 mm²) ≤ 0.387 Ω/km Power cores
  Insulation resistance ≥ 1000 MΩ·km MgO — very high
  Routine test voltage (AC) 3.5 kV / 5 min — Power-frequency
  Fire circuit test 950 °C / 180 min — Cable remains energised
  Circuit integrity BS 6387 class C — 950 °C, no circuit failure
05 · Thermal & Fire
  Max continuous conductor temp. 105 °C MgO — higher than XLPE
  Short-circuit temp. 250 °C Cu conductor limit
  Fire rating 950 °C / 180 min BS 6387 class C
  Flame spread None — MgO + Cu tube non-combustible
  Toxic gas emission None — Mineral — no halogen
  Halogen-free Yes — MgO mineral, no halogen
  Water resistance Good — Cu tube is water-tight
06 · Mechanical
  Min bending radius (fixed) ≥ 12 × OD ≈ 460 mm Corrugated Cu tube
  Min bending radius (flexed) ≥ 15 × OD ≈ 580 mm Repeated flexing
  Crush resistance Excellent — Cu tube is rigid
  Outer sheath PVC corrosion protection — Cu tube main protection
07 · Ampacity
  Air ampacity (4×50 loaded) ≈ 175 A 30 °C (est.)
  Buried ampacity ≈ 185 A Direct burial
  Fire circuit derating 80% — For fire-rated circuits
08 · Installation
  Laying methods Tray, conduit, vertical riser, fire-rated enclosure — Emergency power
  Terminations Special mineral cable end seals — Critical — must seal MgO
  Connectors Cu lugs + end sealing kits — Moisture barrier required
  Special tools MgO cable end sealing kit — Moisture-proof termination
09 · Packing
  Standard supply length 100 m / drum m Fire cable
  Reel / packing type Wooden drum, sealed ends — Ends must be sealed
  Surface marking BTTRZ, 4×50+1×25, 0.6/1kV, 950°C, metre marks — Continuous printing
  Storage conditions Dry, indoor, sealed ends — MgO is hygroscopic
10 · Applications
  Typical use Fire pump power, emergency lighting, smoke control, fire alarm circuits, evacuation systems, critical life-safety circuits — Fire-rated emergency power
  Max system voltage 1.2 kV (Um) 0.6/1 kV rated
  Fire duration 950 °C / 180 min — BS 6387 class C

 

Test Parameters

 

Test Parameters — BTTRZ 4×50+1×25 mm²
No. Test Item Test Condition / Method Requirement Type
1 Conductor DC resistance GB/T 3956, 20 °C ≤ 0.387 Ω/km (50mm²), ≤ 0.741 Ω/km (25mm²) Routine
2 Power-frequency withstand 3.5 kV AC, 5 min No breakdown Routine
3 Insulation resistance 500 V DC, between Cu tube and conductor ≥ 1000 MΩ·km Routine
4 Fire resistance test BS 6387 class C: 950 °C, 180 min Cable remains energised, no circuit failure Type
5 Impact test during fire BS 6387: mechanical impact at flame Circuit remains intact Type
6 Water spray during fire BS 6387: water spray at flame Circuit remains intact Type
7 Crush test Cu tube crush resistance No conductor exposure Type
8 Dimensional check Micrometer OD ≈ 38.5 mm, Cu tube ≈ 0.9 mm Routine
9 End seal integrity Visual + insulation resistance Moisture-proof seals Routine
10 Corrugation check Visual Uniform corrugated Cu tube Routine
11 Conductor continuity Per GB/T 3956 All 5 cores continuous Routine
12 Toxicity / halogen test IEC 60754 / IEC 60754-2 Zero halogen, zero toxic gas Type

 

Cable Cross Section Structure

 

BTTRZ X50mm2+1x25mm2 Fire Resistant Cable Mineral Emergency Power Copper Sheathed Cable

 

BTTRZ 4×50+1×25 mm² — Cross-Section Construction Diagram (Schematic)
Fire-resistant cable: Cu conductors → MgO mineral insulation → corrugated Cu tube (fire barrier) → PVC outer sheath · 0.6/1 kV · 950 °C / 180 min · finished Ø ≈ 38.5 mm
No. Layer Material / Construction Nominal Thickness (mm) Diameter (mm) Function / Remarks
1 Conductors (×5) Copper: 4×50 mm² (L1/L2/L3/N) + 1×25 mm² (PE) — ≈ 9.5 / 6.3 R ≤ 0.387 / 0.741 Ω/km
2 MgO mineral insulation Magnesium oxide (MgO) powder, compacted ≈ 1.5 around each — Non-combustible, 950 °C rated
3 Corrugated Cu tube Continuous welded corrugated copper ≈ 0.9 ≈ 36.5 Fire barrier, water-tight, crush-resistant
4 Outer PVC sheath PVC, black/red (corrosion protection) ≈ 1.0 ≈ 38.5 (finished) Protects Cu tube from corrosion
Key Dimensions & Properties (expanded)
Finished cable diameter ≈ 38.5 mm Cu tube + PVC sheath    
Approx. cable mass ≈ 3850 kg/km Cu conductors + MgO + Cu tube + PVC    
Nominal voltage rating 0.6/1 kV Fire-rated power circuit    
Max continuous conductor temp. 105 °C MgO mineral insulation    
Fire rating 950 °C / 180 min BS 6387 class C    
Short-circuit temp. 250 °C Cu conductor limit    
Min bending radius (fixed) ≥ 12 × OD ≈ 460 mm Corrugated Cu tube    
DC resistance @ 20 °C (50 mm²) ≤ 0.387 Ω/km Power cores    
DC resistance @ 20 °C (25 mm²) ≤ 0.741 Ω/km PE core    
Insulation resistance ≥ 1000 MΩ·km MgO — very high    
Routine test voltage (AC) 3.5 kV / 5 min — Power-frequency withstand    
Air ampacity @ 30 °C ≈ 175 A 4 cores loaded (est.)    
Halogen-free Yes — MgO mineral, no halogen    
Toxic gas emission None — Non-combustible mineral    
Schematic — not to exact scale. Finished Ø ≈ 38.5 mm and weight ≈ 3850 kg/km from cross-referenced industry samples. BTTRZ is a flexible mineral-insulated (MgO) copper-sheathed fire-resistant cable — copper conductors embedded in compacted magnesium oxide powder, enclosed in a continuous corrugated copper tube. Unlike RVV-5×4.0 (PVC 70 °C, 300/500 V, 25 A, 350 kg/km, 5-core flexible PVC), BTTRZ uses MgO mineral insulation (950 °C fire-rated), a rigid copper tube sheath (fire barrier), and is designed for emergency power circuits that must survive fire. The Cu tube itself is the fire barrier — it does not burn, does not emit toxic gas, and maintains circuit integrity at 950 °C for 3 hours. Special end seals are required to keep MgO dry. Values marked (est.) require confirmation against the factory test certificate.

 

Construction Description

 

Construction Description — BTTRZ 4×50+1×25 mm² (mineral-insulated fire cable)
Layer-by-layer fire-resistant cable: Cu conductors / MgO mineral insulation / corrugated Cu tube (fire barrier) / PVC outer sheath · 0.6/1 kV · 950 °C / 180 min · finished Ø ≈ 38.5 mm
1. Product Identity & Ratings
BTTRZ 4×50+1×25 is a flexible mineral-insulated (MgO) copper-sheathed fire-resistant cable rated 0.6/1 kV, built and tested per GB/T 13033 / BS 6387. It has 4 power cores (50 mm², L1/L2/L3/N) + 1 PE core (25 mm²), all embedded in compacted magnesium oxide powder inside a continuous corrugated copper tube. The cable maintains circuit integrity at 950 °C for 180 minutes. Unlike RVV-5×4.0 (PVC 70 °C, 300/500 V, 25 A, 350 kg/km), BTTRZ is a fire-rated emergency power cable. Finished Ø ≈ 38.5 mm, mass ≈ 3850 kg/km, wooden drums.
2. Copper Conductors (4×50 + 1×25)
The 4 power cores use 50 mm² copper conductors (R ≤ 0.387 Ω/km), and the PE core uses 25 mm² copper (R ≤ 0.741 Ω/km). Conductors are solid or stranded per GB/T 3956. All 5 cores are embedded in MgO mineral powder inside the copper tube. The copper conductors themselves can survive temperatures far above PVC/XLPE cables because MgO does not melt or burn.
3. MgO Mineral Insulation
Magnesium oxide (MgO) is a non-combustible mineral powder compacted around each conductor. Unlike PVC or XLPE (which burn, melt, and release toxic gas), MgO remains stable at 950 °C. This is the core advantage of mineral-insulated cables — the insulation itself does not burn. MgO is hygroscopic, so the cable ends must be sealed with special end seals to prevent moisture ingress.
4. Corrugated Copper Tube (Fire Barrier)
The MgO-insulated conductors are enclosed in a continuous welded corrugated copper tube (≈ 0.9 mm wall). The copper tube serves three functions: (1) fire barrier — copper does not burn; (2) water-tight seal — protects MgO from moisture; (3) mechanical protection — crush-resistant. The corrugations allow some flexibility while maintaining the seal. This is fundamentally different from RVV's PVC outer sheath, which melts and burns.
5. Site Handling & Operational Notes
• CRITICAL: Install special MgO end seals at both ends — MgO is hygroscopic and will absorb moisture if unsealed.  • Bend radius 12×OD (≈ 460 mm) fixed.  • Fire rating: 950 °C / 180 min (BS 6387 class C).  • Use Cu compression lugs + end sealing kits.  • PVC outer sheath is for corrosion protection only — the Cu tube is the primary barrier.  • At 3850 kg/km, supplied on heavy wooden drums.  • Store with ends sealed.  • For fire pump, emergency lighting, smoke control circuits.

 

 

8. Cable Structure Display

 

BTTRZ X50mm2+1x25mm2 Fire Resistant Cable Mineral Emergency Power Copper Sheathed Cable

 

9. Packaging, Storage & Logistics. 100 m per wooden drum with sealed ends. Continuous marking: BTTRZ, 4×50+1×25, 0.6/1 kV, 950 °C, GB/T 13033, metre marks. Store dry, indoor, with factory end seals intact.

 

BTTRZ X50mm2+1x25mm2 Fire Resistant Cable Mineral Emergency Power Copper Sheathed Cable

 

10. Procurement Specification. State "BTTRZ 4×50+1×25, 0.6/1 kV, 950 °C/180 min" + length. Order matching end sealing kits. Confirm against factory fire test certificate. Do not substitute ordinary YJV for fire-rated circuits.

11. Cable Industry FAQ.

  • Q1: What makes BTTRZ fire-resistant? Unlike RVV (PVC insulation which burns and melts at 70 °C), BTTRZ uses magnesium oxide (MgO) — a non-combustible mineral powder — as insulation, and a solid copper tube as the sheath. Neither MgO nor copper burns. The cable can maintain circuit integrity at 950 °C for 3 hours.
  • Q2: Why are end seals so critical? MgO powder is hygroscopic — it absorbs moisture from air. If the cable ends are left unsealed, moisture enters the MgO, lowering insulation resistance. Special end sealing kits must be installed at both ends immediately after cutting.
  • Q3: What is the difference between BTTZ and BTTRZ? BTTZ uses a solid (non-corrugated) copper tube — rigid, hard to bend. BTTRZ uses a corrugated copper tube — flexible, easier to install. Both are mineral-insulated; BTTRZ is the flexible version.
  • Q4: Can BTTRZ be used for normal power distribution? Yes, but it is significantly more expensive than YJV. Use BTTRZ only for fire-rated emergency circuits (fire pump, emergency lighting, smoke control). For normal distribution, use YJV.
  • Q5: Why is the cable so heavy (3850 kg/km)? The solid copper tube (≈ 0.9 mm wall over Ø 36.5 mm) is thick copper — much heavier than a PVC sheath. RVV's PVC sheath weighs ~50 kg/km; BTTRZ's copper tube alone weighs ~1500 kg/km.
  • Q6: Does BTTRZ need armor? No — the copper tube itself provides excellent crush and impact resistance. This is why it is the standard for fire-rated circuits.
  • Q7: What is the maximum conductor temperature? 105 °C continuous (higher than XLPE's 90 °C), because MgO can withstand far more heat. Short-circuit temperature up to 250 °C.
  • Q8: Can BTTRZ be buried directly? Yes — the copper tube is water-tight and corrosion-resistant (with the PVC outer sheath). No additional armor needed for direct burial.
  • Q9: What is the difference between BS 6387 classes? Class A = 950 °C / 3 hours (highest); Class B = 950 °C / 90 min; Class C = 950 °C / 180 min. BTTRZ meets class C. Class A/B require higher fire ratings.
  • Q10: Can RVV be used for fire pump circuits? No — RVV's PVC insulation burns at ~250 °C and releases toxic smoke. Fire pump circuits MUST use mineral-insulated cable (BTTRZ/BTTZ) or fire-rated silicone cable.
  • Q11: How do I terminate BTTRZ? Cut the cable square, remove the outer PVC, slide on the end seal gland, fill with sealing compound, install the Cu lug, and crimp. The seal must be moisture-tight. Improper termination is the #1 failure point for mineral-insulated cables.