logo
Anhui Tongdu International Trade Co., Ltd.
Layanan online

Layanan online

Kontak person
+86 19056002718
Kode QR WeChat
Ikuti kami.

Kabel Tahan Api

kualitas BTTRZ X50mm2+1x25mm2 Kabel tahan api Kabel berlapis tembaga pabrik

BTTRZ X50mm2+1x25mm2 Kabel tahan api Kabel berlapis tembaga

BTTRZ x50mm²+1x25mm² Mineral Insulated Fire Resistant Copper Sheathed Cable for Emergency Power Cable Designation & Meaning Code Meaning B Fixed wiring cable (Class B — building wire/power cable) T Copper conductor (Tong = copper) T Copper sheath (Tong = copper) R Flexible (Rou = flexible) Z Heavy ...

kualitas Kabel Tahan Api BTLY 4x35mm2 + 1x16mm2 Selubung Aluminium Untuk Darurat pabrik

Kabel Tahan Api BTLY 4x35mm2 + 1x16mm2 Selubung Aluminium Untuk Darurat

NG-A BTLY 4x35+1x16mm2 Mineral Insulated Fire Resistant Aluminum Sheath Cable for Emergency Cable Designation & Meaning Code Meaning NG-A New Generation A-class fire-resistant (Chinese designation) (BTLY) Building wire, Thin copper conductor, Lightweight Y— alternative naming convention indicating: ...

kualitas 4x185mm2 + 1x150mm2 Kabel tahan api 0.6KV 1KV Kabel tembaga terisolasi mineral pabrik

4x185mm2 + 1x150mm2 Kabel tahan api 0.6KV 1KV Kabel tembaga terisolasi mineral

Super Fire Cable BTTRZ 4x185mm²+1x150mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...

kualitas BTTRZ Kabel tahan api 4x150mm2 + 1x120mm2 Kabel terisolasi mineral pabrik

BTTRZ Kabel tahan api 4x150mm2 + 1x120mm2 Kabel terisolasi mineral

Ultra Fire Cable BTTRZ 4x150mm²+1x120mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 ...

kualitas 4+1 Kabel tahan api inti 120mm2+1x95mm2 Kabel Substasiun Api BTTRZ pabrik

4+1 Kabel tahan api inti 120mm2+1x95mm2 Kabel Substasiun Api BTTRZ

Fire Substation Cable 4+1 Core 120mm²+1x95mm² BTTRZ Fire Resistant Mineral Insulated Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6...

kualitas Kabel pemanas terisolasi mineral berukuran 4x95mm2+1x70mm2 pabrik

Kabel pemanas terisolasi mineral berukuran 4x95mm2+1x70mm2

Large Fire Cable BTTRZ 4x95mm²+1x70mm² Mineral Insulated 0.6/1kV Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV ...

kualitas 4x70mm2 + 1x50mm2 Kabel tahan api 1KV 1.2KV Kabel terisolasi tembaga mineral pabrik

4x70mm2 + 1x50mm2 Kabel tahan api 1KV 1.2KV Kabel terisolasi tembaga mineral

Heavy Duty Fire Cable BTTRZ 4x70mm²+1x50mm² Mineral Insulated 0.6/1kV Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV Rated ...

kualitas Kabel Pemanas Mineral Tahan Api Kritis Rumah Sakit 3200kg/Km Mi pabrik

Kabel Pemanas Mineral Tahan Api Kritis Rumah Sakit 3200kg/Km Mi

Hospital Critical Cable BTTRZ 4x35mm²+1x16mm² Mineral Insulated Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV ...

kualitas 25 mm2 Kabel tahan api 4x25mm2 + 1x16mm2 Tembaga terisolasi mineral pabrik

25 mm2 Kabel tahan api 4x25mm2 + 1x16mm2 Tembaga terisolasi mineral

0.6/1kV Mineral Insulated Cable BTTRZ 4x25mm²+1x16mm² Fire Resistant Cable Designation & Meaning Code Meaning BTTRZ B = Wiring cable (fixed installation); T = Copper conductor (flexible); T = Copper sheath (corrugated welded tube); R = Flexible; Z = Heavy-duty (mineral insulated) 0.6/1 kV Rated ...

Sebelumnya 1 2 Berikutnya